1
|
Heo T, Lee NK, Kim S, Hong SB, Suh DS, Kim JY, Lee JW, Kim TU. Deep learning reconstruction of diffusion-weighted imaging with single-shot echo-planar imaging in endometrial cancer: a comparison with multi-shot echo-planar imaging. Abdom Radiol (NY) 2025:10.1007/s00261-025-04955-3. [PMID: 40249551 DOI: 10.1007/s00261-025-04955-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2025] [Revised: 04/07/2025] [Accepted: 04/11/2025] [Indexed: 04/19/2025]
Abstract
PURPOSE To evaluate the efficacy of deep learning reconstruction (DLR) in diffusion-weighted imaging (DWI) with single-shot echo-planar imaging (SSEPI) for endometrial cancer, compared to multiplexed sensitivity-encoding (MUSE) DWI. METHODS We retrospectively reviewed 31 women with surgically confirmed endometrial cancer who underwent preoperative pelvic magnetic resonance imaging (MRI) including DWI. Qualitative analysis including overall image quality, susceptibility artifacts, sharpness of the uterine edge, and lesion conspicuity were compared among conventional SSEPI (SSEPI-C), SSEPI with DLR (SSEPI-DL), and MUSE using the Friedman's test. Quantitative analysis including the apparent diffusion coefficient (ADC) values, noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were also compared among three DWI sequences using the Friedman's test. In addition, the diagnostic accuracy for deep myometrial invasion was compared to three DWI sequences using Cochran's Q test. RESULTS The scores of overall image quality, sharpness of the uterine edge, and lesion conspicuity in SSEPI-DL were higher than SSEPI-C (p < 0.001) with no significant difference compared to MUSE (p > 0.05). Noise in SSEPI-DL was lower than SSEPI-C (p < 0.001), with no significant difference compared to MUSE (p > 0.05). SNR and CNR in SSEPI-DL were also superior to SSEPI-C (p < 0.001), and comparable to MUSE (p > 0.05). The diagnostic accuracy for detecting deep myometrial invasion showed no significant difference among SSEPI-C, SSEPI-DL and MUSE (p > 0.05). CONCLUSION DLR improves the image quality of DWI in endometrial cancer, demonstrating image quality equivalent to that of SSEPI-DL and MUSE. SSEPI-DL can be an alternative to MUSE in female pelvic MRI, with the benefit of significantly shortened scan time.
Collapse
Affiliation(s)
- Taewoo Heo
- Department of Radiology, and Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Republic of Korea
| | - Nam Kyung Lee
- Department of Radiology, and Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Republic of Korea.
| | - Suk Kim
- Department of Radiology, and Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Republic of Korea
| | - Seung Baek Hong
- Department of Radiology, and Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Republic of Korea
| | - Dong Soo Suh
- Department of Obstetrics and Gynecology, and Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Republic of Korea
| | - Jin You Kim
- Department of Radiology, and Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Republic of Korea
| | - Ji Won Lee
- Department of Radiology, and Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Republic of Korea
| | - Tae Un Kim
- Department of Radiology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, Republic of Korea
| |
Collapse
|
2
|
Xiao Y, Yang F, Deng Q, Ming Y, Tang L, Yue S, Li Z, Zhang B, Liang H, Huang J, Sun J. Comparison of conventional diffusion-weighted imaging and multiplexed sensitivity-encoding combined with deep learning-based reconstruction in breast magnetic resonance imaging. Magn Reson Imaging 2025; 117:110316. [PMID: 39716684 DOI: 10.1016/j.mri.2024.110316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2024] [Revised: 12/17/2024] [Accepted: 12/18/2024] [Indexed: 12/25/2024]
Abstract
PURPOSE To evaluate the feasibility of multiplexed sensitivity-encoding (MUSE) with deep learning-based reconstruction (DLR) for breast imaging in comparison with conventional diffusion-weighted imaging (DWI) and MUSE alone. METHODS This study was conducted using conventional single-shot DWI and MUSE data of female participants who underwent breast magnetic resonance imaging (MRI) from June to December 2023. The k-space data in MUSE were reconstructed using both conventional reconstruction and DLR. Two experienced radiologists conducted quantitative analyses of DWI, MUSE, and MUSE-DLR images by obtaining the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) of lesions and normal tissue and qualitative analyses by using a 5-point Likert scale to assess the image quality. Inter-reader agreement was assessed using the intraclass correlation coefficient (ICC). Image scores, SNR, CNR, and apparent diffusion coefficient (ADC) measurements among the three sequences were compared using the Friedman test, with significance defined at P < 0.05. RESULTS In evaluations of the images of 51 female participants using the three sequences, the two radiologists exhibited good agreement (ICC = 0.540-1.000, P < 0.05). MUSE-DLR showed significantly better SNR than MUSE (P < 0.001), while the ADC values within lesions and tissues did not differ significantly among the three sequences (P = 0.924, P = 0.636, respectively). In the subjective assessments, MUSE and MUSE-DLR scored significantly higher than conventional DWI in overall image quality, geometric distortion and axillary lymph node (P < 0.001). CONCLUSION In comparison with conventional DWI, MUSE-DLR yielded improved image quality with only a slightly longer acquisition time.
Collapse
Affiliation(s)
- Yitian Xiao
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Fan Yang
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Qiao Deng
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Yue Ming
- West China School of Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Lu Tang
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Shuting Yue
- West China School of Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Zheng Li
- West China School of Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Bo Zhang
- GE HealthCare MR Research, Beijing, China
| | | | - Juan Huang
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China.
| | - Jiayu Sun
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China.
| |
Collapse
|
3
|
Wang MY, Yu Y, Han Y, Yang Y, Jiang W, Liu J, Yan LF, Cui GB. The Diagnostic Value of Conventional MRI Combined With Diffusion-Weighted Imaging in Microprolactinomas. J Magn Reson Imaging 2025; 61:1155-1167. [PMID: 38996369 DOI: 10.1002/jmri.29531] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 06/21/2024] [Accepted: 06/21/2024] [Indexed: 07/14/2024] Open
Abstract
BACKGROUND Turbo spin-echo (TSE) diffusion-weighted imaging (DWI) sequences may reduce susceptibility artifacts and image distortion in sellar region, allowing better visualization of small pituitary lesions, and may be used to assist in the diagnosis of pituitary microadenomas. PURPOSE To explore the application value of conventional MRI combined with DWI sequences in the diagnosis of microprolactinomas. STUDY TYPE Prospective. POPULATION Thirty-four patients in microprolactinomas with high signal on T2WI (HT2-PRL) group (34 females, 34 ± 7 years), 26 patients in microprolactinomas with equal or low signal on T2WI (ELT2-PRL) group (21 females, 34 ± 7 years), 35 patients with hyperprolactinemia (33 females, 32 ± 8 years), and 30 normal controls (25 females, 31 ± 7 years). FIELD STRENGTH/SEQUENCE TSE sequence at 3 T. ASSESSMENT Pituitary morphological parameters (such as length and volume), dynamic contrast-enhanced parameters (such as time to peak) and the apparent diffusion coefficients (ADCs) were measured in each group. STATISTICAL TESTS ANOVA and Mann-Whitney U test were used to compare parameters among groups. Spearman's coefficient was used to evaluate the correlation between variables. ROC analysis was used to assess the performance of the parameters. A P-value <0.05 was considered statistically significant. RESULTS The pituitary volume of patients in HT2-PRL, ELT2-PRL, and hyperprolactinemia group were 831.00 (747.60, 887.60), 923.63 ± 219.34, and 737.20 (606.40, 836.80) mm3. The pituitary maximum height in these three groups were 7.03 (6.43, 8.63), 8.03 ± 1.41, and 6.63 ± 1.28 mm, respectively. The lesion ADC value was significantly correlated with T2 relative signal intensity (the ratio of signal intensity of microprolactinoma or anterior pituitary to left temporal cortex) (r = 0.821). Compared with patients with hyperprolactinemia, the diagnostic efficacy of T2 relative signal intensity was higher in HT2-PRL group, with an AUC of 0.954, whereas the ADC value was the highest in ELT2-PRL group, with an AUC of 0.924. CONCLUSION DWI sequences can be used to assist in the diagnosis of pituitary microadenomas. EVIDENCE LEVEL 1 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Min-Yang Wang
- Department of Radiology & Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, The Military Medical University of PLA Airforce (Fourth Military Medical University), Xi'an, Shaanxi, China
| | - Ying Yu
- Department of Radiology & Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, The Military Medical University of PLA Airforce (Fourth Military Medical University), Xi'an, Shaanxi, China
| | - Yu Han
- Department of Radiology & Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, The Military Medical University of PLA Airforce (Fourth Military Medical University), Xi'an, Shaanxi, China
| | - Yang Yang
- Department of Radiology & Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, The Military Medical University of PLA Airforce (Fourth Military Medical University), Xi'an, Shaanxi, China
| | - Wan Jiang
- Department of Radiology & Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, The Military Medical University of PLA Airforce (Fourth Military Medical University), Xi'an, Shaanxi, China
- The Affiliated Hospital of Yan'an University School of Medicine, Yan'an, Shaanxi, China
| | - Jin Liu
- Department of Radiology & Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, The Military Medical University of PLA Airforce (Fourth Military Medical University), Xi'an, Shaanxi, China
| | - Lin-Feng Yan
- Department of Radiology & Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, The Military Medical University of PLA Airforce (Fourth Military Medical University), Xi'an, Shaanxi, China
| | - Guang-Bin Cui
- Department of Radiology & Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, The Military Medical University of PLA Airforce (Fourth Military Medical University), Xi'an, Shaanxi, China
| |
Collapse
|
4
|
Nakamoto A, Onishi H, Tsuboyama T, Fukui H, Ota T, Yano K, Kiso K, Honda T, Tarewaki H, Koyama Y, Tatsumi M, Tomiyama N. High-resolution Diffusion-weighted Imaging of the Prostate Using Multiplexed Sensitivity-encoding: Comparison with the Conventional and Reduced Field-of-view Techniques. Magn Reson Med Sci 2025; 24:58-65. [PMID: 37899224 PMCID: PMC11733513 DOI: 10.2463/mrms.mp.2023-0039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Accepted: 09/22/2023] [Indexed: 10/31/2023] Open
Abstract
PURPOSE To compare objective and subjective image quality, lesion conspicuity, and apparent diffusion coefficient (ADC) of high-resolution multiplexed sensitivity-encoding diffusion-weighted imaging (MUSE-DWI) with conventional DWI (c-DWI) and reduced FOV DWI (rFOV-DWI) in prostate MRI. METHODS Forty-seven patients who underwent prostate MRI, including c-DWI, rFOV-DWI, and MUSE-DWI, were retrospectively evaluated. SNR and ADC of normal prostate tissue and contrast-to-noise ratio (CNR) and ADC of prostate cancer (PCa) were measured and compared between the three sequences. Image quality and lesion conspicuity were independently graded by two radiologists using a 5-point scale and compared between the three sequences. RESULTS The SNR of normal prostate tissue was significantly higher with rFOV-DWI than with the other two DWI techniques (P ≤ 0.01). The CNR of the PCa was significantly higher with rFOV-DWI than with MUSE-DWI (P < 0.05). The ADC of normal prostate tissue measured by rFOV-DWI was lower than that measured by MUSE-DWI and c-DWI (P < 0.01), while there was no difference in the ADC of cancers. In the qualitative analysis, MUSE-DWI showed significantly higher scores than rFOV-DWI and c-DWI for visibility of anatomy and overall image quality in both readers, and significantly higher scores for distortion in one of the two readers (P < 0.001). There was no difference in lesion conspicuity between the three sequences. CONCLUSION High-resolution MUSE-DWI showed higher image quality and reduced distortion compared to c-DWI, while maintaining a wide FOV and similar ADC quantification, although no difference in lesion conspicuity was observed.
Collapse
Affiliation(s)
- Atsushi Nakamoto
- Department of Future Diagnostic Radiology, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Hiromitsu Onishi
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Takahiro Tsuboyama
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Hideyuki Fukui
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Takashi Ota
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Keigo Yano
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Kengo Kiso
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Toru Honda
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Hiroyuki Tarewaki
- Division of Radiology, Department of Medical Technology, Osaka University Hospital, Osaka, Japan
| | - Yoshihiro Koyama
- Division of Radiology, Department of Medical Technology, Osaka University Hospital, Osaka, Japan
| | - Mitsuaki Tatsumi
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Noriyuki Tomiyama
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, Osaka, Japan
| |
Collapse
|
5
|
Wang Y, Cui Y, Dai J, Ni S, Zhang T, Chen X, Jiang Q, Cheng Y, Ma Y, Li T, Xiao Y. Prospective Comparison of FOCUS MUSE and Single-Shot Echo-Planar Imaging for Diffusion-Weighted Imaging in Evaluating Thyroid-Associated Ophthalmopathy. Korean J Radiol 2024; 25:913-923. [PMID: 39344548 PMCID: PMC11444853 DOI: 10.3348/kjr.2024.0177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Revised: 07/30/2024] [Accepted: 08/02/2024] [Indexed: 10/01/2024] Open
Abstract
OBJECTIVE To prospectively compare single-shot (SS) echo-planar imaging (EPI) and field-of-view optimized and constrained undistorted single-shot multiplexed sensitivity-encoding (FOCUS MUSE) for diffusion-weighted imaging (DWI) in evaluating thyroid-associated ophthalmopathy (TAO). MATERIALS AND METHODS SS EPI and FOCUS MUSE DWIs were obtained from 39 patients with TAO (18 male; mean ± standard deviation: 48.3 ± 13.3 years) and 26 healthy controls (9 male; mean ± standard deviation: 43.0 ± 18.5 years). Two radiologists scored the visual image quality using a 4-point Likert scale. The image quality score, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) of extraocular muscles (EOMs) were compared between the two DWIs. Differences in the ADC of EOMs were also evaluated. The performance of discriminating active from inactive TAO was assessed using receiver operating characteristic curves. The correlation between ADC and clinical activity score (CAS) was analyzed using Spearman correlation. RESULTS Compared with SS EPI DWI, FOCUS MUSE DWI demonstrated significantly higher image quality scores (P < 0.001), a higher SNR and CNR on the lateral rectus muscle (LRM) and medial rectus muscle (MRM) (P < 0.05), and a non-significant difference in the ADC of the LRM and MRM. Active TAO showed higher ADC than inactive TAO and healthy controls with both SS EPI and FOCUS MUSE DWIs (P < 0.001). Inactive TAO and healthy controls did not show a significant ADC difference with both DWIs. Compared with SS EPI DWI, FOCUS MUSE DWI demonstrated better discrimination of active from inactive TAO (AUC: 0.925 vs. 0.779; P = 0.007). The ADC was significantly correlated with CAS in SS EPI DWI (r = 0.391, P < 0.001) and FOCUS MUSE DWI (r = 0.645, P < 0.001). CONCLUSION FOCUS MUSE DWI provides better images for evaluating EOMs and better performance in diagnosing active TAO than SS EPI DWI. The application of FOCUS MUSE will facilitate the DWI evaluation of TAO.
Collapse
Affiliation(s)
- YunMeng Wang
- Graduate School of Bengbu Medical University, Bengbu, China
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | - YuanYuan Cui
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | | | - ShuangShuang Ni
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | - TianRan Zhang
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | - Xin Chen
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | - QinLing Jiang
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | - YuXin Cheng
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | - YiChuan Ma
- Department of Radiology, The First Affiliated Hospital of Bengbu Medical University, Bengbu, China
| | - Tuo Li
- Department of Endocrinology, Changzheng Hospital, Shanghai, China
| | - Yi Xiao
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China.
| |
Collapse
|
6
|
Li J, Xia Y, Dai J, Sun G, Xu M, Lin X, Gu L, Shi J, Liu S, Fan L. Comparison of single-shot, FOCUS single-shot, MUSE, and FOCUS MUSE diffusion weighted imaging for pulmonary lesions: A pilot study. Heliyon 2024; 10:e35203. [PMID: 39170364 PMCID: PMC11336438 DOI: 10.1016/j.heliyon.2024.e35203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Revised: 07/23/2024] [Accepted: 07/24/2024] [Indexed: 08/23/2024] Open
Abstract
Rationale and objectives To compare the performance of SS, FOCUS SS, MUSE, and FOCUS MUSE DWI for pulmonary lesions to obtain a better technique for pulmonary DWI imaging. Materials and methods 44 patients with pulmonary lesions were recruited to perform pulmonary DWI using SS, FOCUS SS, MUSE, and FOCUS MUSE sequences. Then, two radiologists with 12 and 10 years of chest MRI experiences assessed the overall image quality while another two radiologists both with 3 years of experiences evaluated the SNR, DR, and ADC of pulmonary lesions. Using interclass correlation coefficient (ICC) and kappa statistics to assess consistency of readers, Friedman test and Dunn-Bonferroni post hoc were used to calculate the difference between sequences. Mann-Whitney test and ROC curve were used to distinguish malignant from benign lesions. Results All the assessed variables of the four sequences presented good to excellent intra-/inter-observer consistency. Compared with SS, FOCUS SS and MUSE, FOCUS MUSE demonstrated better image quality, including significantly higher 5-point Likert scale score (P < 0.001) and smaller DR (P < 0.001). SNR was comparable among SS, FOCUS SS, and FOCUS MUSE (P > 0.05) while MUSE presented with significantly higher SNR over them (P < 0.01). ADC of malignant was significantly smaller than that of benign for all the four sequences (P < 0.05). ROC analysis showed relatively better diagnostic performance of FOCUS MUSE (AUC = 0.820) over SS (AUC = 0.748), FOCUS SS (AUC = 0.778), and MUSE (AUC = 0.729) in distinguishing malignant from benign lesions. Conclusion FOCUS MUSE possessed sufficient SNR and was better over SS, FOUCS SS, and MUSE for characterizing pulmonary lesions.
Collapse
Affiliation(s)
- Jie Li
- College of Health Sciences and Engineering, University of Shanghai for Science and Technology, No.516 Jungong Road, Shanghai, 200093, China
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, No. 415 Fengyang Road, Shanghai, 200003, China
| | - Yi Xia
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, No. 415 Fengyang Road, Shanghai, 200003, China
| | | | - GuangYuan Sun
- Department of Thoracic Surgery, Second Affiliated Hospital of Naval Medical University, No. 415 Fengyang Road, Shanghai, 200003, China
| | - MeiLing Xu
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, No. 415 Fengyang Road, Shanghai, 200003, China
| | - XiaoQing Lin
- College of Health Sciences and Engineering, University of Shanghai for Science and Technology, No.516 Jungong Road, Shanghai, 200093, China
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, No. 415 Fengyang Road, Shanghai, 200003, China
| | - LingLing Gu
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, No. 415 Fengyang Road, Shanghai, 200003, China
| | - Jie Shi
- GE Healthcare, Beijing, 100000, China
| | - ShiYuan Liu
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, No. 415 Fengyang Road, Shanghai, 200003, China
| | - Li Fan
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, No. 415 Fengyang Road, Shanghai, 200003, China
| |
Collapse
|
7
|
Zhao W, Liu Q, Sun J, Pan W, Pylypenko D, Wang W. Evaluating the image quality and local tumor invasion of uterine cancer by MUSE DWI with RPG. Heliyon 2024; 10:e35440. [PMID: 39170139 PMCID: PMC11336590 DOI: 10.1016/j.heliyon.2024.e35440] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2024] [Revised: 07/28/2024] [Accepted: 07/29/2024] [Indexed: 08/23/2024] Open
Abstract
Diffusion-weighted imaging (DWI) is widely utilized for evaluating uterine diseases. However, the prevalent technique, single-shot echo planar imaging (ssEPI), is hindered by notable image distortion and low spatial resolution. Therefore, optimizing uterine DWI sequences is vital for improving image quality. To investigate the efficacy of multiplexed sensitivity encoding (MUSE) combined with reverse polarity gradient (RPG) in enhancing uterine DWI quality and assessing local invasion in endometrial and cervical cancer, we included 149 patients. Each patient underwent DWI of the uterus using ssEPI, MUSE, and RPG-MUSE techniques. We compared these three sequences regarding image quality, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), geometric distortion rate (GDR), ADC values, accuracy in determining the extent of cancer invasion, and the Area Under the Curve (AUC) for identifying endometrial cancer and benign endometrial lesions using ADC values. The results indicated that RPG-MUSE DWI had less artifacts than MUSE and ssEPI (P < 0.05). Lesions were more apparent in MUSE and RPG-MUSE sequences compared to ssEPI (P < 0.05), with RPG-MUSE providing clearer lesion edges (P < 0.05). Additionally, RPG-MUSE DWI demonstrated higher SNR and CNR than ssEPI and MUSE (P < 0.05), along with a lower GDR (P < 0.05). The ADC values did not show significant differences among the three sequences (P > 0.05). Furthermore, the AUC of the ROC for detecting endometrial cancer and benign endometrial lesions using ADC values showed no significant differences across the sequences (P = 0.7609, 0.7186, and 0.8706, respectively). When combining each DWI sequence with T2WI for FIGO staging, RPG-MUSE and MUSE exhibited better alignment with pathology findings compared to ssEPI (P < 0.05). Overall, RPG-MUSE DWI showed fewer artifacts, higher SNR and CNR, reduced geometric distortion, and clearer lesion visualization compared to ssEPI and MUSE, leading to a more precise assessment of endometrial and cervical cancer invasion extent.
Collapse
Affiliation(s)
- Wenjing Zhao
- Department of Radiology, Weifang People's Hospital, Weifang, Shandong, 261041, China
| | - Qing Liu
- Department of Radiology, Weifang People's Hospital, Weifang, Shandong, 261041, China
| | - Jining Sun
- Department of Radiology, Weifang People's Hospital, Weifang, Shandong, 261041, China
| | - Wenhui Pan
- Department of Radiology, Weifang People's Hospital, Weifang, Shandong, 261041, China
| | | | - Wenjuan Wang
- Department of Radiology, Weifang People's Hospital, Weifang, Shandong, 261041, China
| |
Collapse
|
8
|
Zha F, Feng C, Xu J, Zou Q, Li J, Hu D, Liu WV, Li Z, Wu S. Evaluation of multiplexed sensitivity encoding diffusion-weighted imaging in detecting uterine lesions: Image quality optimization. Magn Reson Imaging 2024; 110:17-22. [PMID: 38452829 DOI: 10.1016/j.mri.2024.03.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Revised: 03/03/2024] [Accepted: 03/03/2024] [Indexed: 03/09/2024]
Abstract
PURPOSE To compare the image quality of multiplexed sensitivity-encoding diffusion-weighted imaging (MUSE-DWI) and single-shot echo-planar imaging (SS-EPI-DWI) techniques in uterine MRI. METHODS Eighty-eight eligible patients underwent MUSE-DWI and SS-EPI-DWI examinations simultaneously using a 3.0 T MRI system. Two radiologists independently performed quantitative and qualitative analysis of the two groups of images using a double-blind method. The weighted Kappa test was used to evaluate the interobserver agreement. Wilcoxon's rank sum test was used for qualitative parameters, and paired t-test was used for quantitative parameters. Spearman rank correlation analysis was used to obtained correlation between pathological results and mean apparent diffusion coefficient (ADC) value. RESULTS The qualitative and quantitative analysis of the images by the two radiologists were in good or excellent agreement, with weighted kappa value ranging from 0.636 to 0.981. The scores of total subjective image quality (15.4 ± 0.99) and signal-to-noise ratio (158.99 ± 60.71) of MUSE-DWI were significantly higher than those of SS-EPI-DWI (12.93 ± 1.62 P < 0.001; 130.23 ± 48.29 P < 0.05). It effectively reduced image distortion and artifact, and had better lesion conspicuity. There was no significant difference in contrast-to-noise ratio score and average ADC values between the two DWI sequences. The average ADC values of the two DWI sequences were highest in the normal uterus group and lowest in the endometrial cancer group, with statistically significant differences among groups (P < 0.01). In addition, the average ADC values of the two DWI sequences were negatively correlated with the type of lesions, decreasing with the malignancy of the lesions (r = -0.805 P < 0.01, r = -0.815 P < 0.01). CONCLUSION Compared to SS-EPI-DWI, MUSE-DWI can significantly reduce distortion, artifacts, and fuzziness in MRI of uterine lesions, which is more conducive to lesion detection.
Collapse
Affiliation(s)
- Fuxiang Zha
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | - Cui Feng
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | - Jin Xu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | - Qian Zou
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | - Jiali Li
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | - Daoyu Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | | | - Zhen Li
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | - Sisi Wu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China.
| |
Collapse
|
9
|
Wang X, Wang P, Zhang H, Wang X, Shi J, Hu S. Multiplexed sensitivity-encoding versus single-shot echo-planar imaging: a comparative study for diffusion-weighted imaging of the thyroid lesions. Jpn J Radiol 2024; 42:268-275. [PMID: 37819591 DOI: 10.1007/s11604-023-01500-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 09/26/2023] [Indexed: 10/13/2023]
Abstract
PURPOSE To compare multiplexed sensitivity-encoding diffusion-weighted magnetic resonance imaging (MUSE-DWI) and conventional DWI (cDWI) techniques in thyroid MRI. MATERIALS AND METHODS Nineteen patients who underwent thyroid MRI using both MUSE-DWI and cDWI at a 3.0 T MRI system were enrolled. Qualitative parameters (image quality, thyroid contour, and lesion conspicuity) and quantitative parameters (signal-to-noise ratio (SNR), lesion-to-thyroid contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC)) were compared between the two sequences. In addition, ADC values derived from MUSE-DWI and cDWI were separately compared between benign and malignant lesions. RESULTS MUSE-DWI outperformed cDWI in terms of image quality, thyroid contour, and lesion conspicuity. Significantly, higher signal-to-noise ratio (SNR) in both the thyroid and its lesion were found in MUSE-DWI than those in cDWI (both P < 0.05). The lesion-to-thyroid contrast-to-noise ratio (CNR) values were also significantly higher in MUSE-DWI than those in cDWI (P < 0.05). The apparent diffusion coefficient (ADC) of the thyroid in MUSE-DWI was significantly lower than that in cDWI (P < 0.05). The ADC of the lesion in MUSE-DWI was also significantly lower than that in cDWI (P < 0.05). In addition, ADC values derived from MUSE-DWI and cDWI were significantly higher in benign lesions than malignant lesions (P < 0.05). CONCLUSION Compared with cDWI, MUSE-DWI can improve the image quality, thyroid contour sharpness, lesion conspicuity, SNR in both the thyroid and its lesions, and enhancing the CNR between lesions and thyroid.
Collapse
Affiliation(s)
- Xiuyu Wang
- Department of Radiology, Affiliated Hospital, Jiangnan University, No.1000, Hefeng Road, Wuxi, 214000, Jiangsu, China
| | - Peng Wang
- Department of Radiology, Affiliated Hospital, Jiangnan University, No.1000, Hefeng Road, Wuxi, 214000, Jiangsu, China
| | - Heng Zhang
- Department of Radiology, Affiliated Hospital, Jiangnan University, No.1000, Hefeng Road, Wuxi, 214000, Jiangsu, China
| | - Xian Wang
- Department of Radiology, Affiliated Renmin Hospital, Jiangsu University, No.8, Dianli Road, Zhenjiang, 212000, Jiangsu, China
| | - Jie Shi
- GE Healthcare, Beijing, 100000, China
| | - Shudong Hu
- Department of Radiology, Affiliated Hospital, Jiangnan University, No.1000, Hefeng Road, Wuxi, 214000, Jiangsu, China.
| |
Collapse
|