1
|
Ceddia M, Solarino G, Cassano GD, Trentadue B. Finite Element Study on Stability in the Femoral Neck and Head Connection to Varying Geometric Parameters with the Relates Implications on the Effect of Wear. JOURNAL OF COMPOSITES SCIENCE 2023; 7:387. [DOI: 10.3390/jcs7090387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/23/2025]
Abstract
Total hip arthroplasty (THA) is a common surgical procedure used to treat hip osteoarthritis and other joint conditions that cause pain and functional limitation. Traditionally, THA has been performed most often in elderly patients, but in recent years, there has been an increase in hip arthroplasties in young patients. Femoral prosthesis rupture is a rare but significant complication that can also occur in young patients undergoing total hip arthroplasty (THA). Some of the factors that can contribute to femoral prosthesis ruptures include abnormal overload, defects in the design, lack of geometric fit, and type of materials used in the stem and femoral head connection. The aim of this study is to analyze the criticalities in the contact between the femoral head and the stem neck. In particular, two types of contacts will be taken into consideration: proximal and distal, and through the finite element method (FEA), the criticalities will be defined. The results show that in the proximal contact, the stress levels exceeded 500 MPa in certain areas of the prosthesis. This stress could potentially lead to structural failure, such as rupture or deformation of the prosthesis. In addition, to prevent bacterial infiltration or debris from the outside, the distal connection is recommended.
Collapse
Affiliation(s)
- Mario Ceddia
- Department of Mechanics, Mathematics and Management, Polytechnic di Bari University, 70125 Bari, Italy
| | - Giuseppe Solarino
- Department of Neuroscience and Organs of Sense, Orthopedic Unit, Faculty of Medicine and Surgery, University of Bari “Aldo Moro”, Policlinic, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Giuseppe Danilo Cassano
- Department of Translational Biomedicine and Neuroscience, University of Bari, 70125 Bari, Italy
| | - Bartolomeo Trentadue
- Department of Mechanics, Mathematics and Management, Polytechnic di Bari University, 70125 Bari, Italy
| |
Collapse
|
2
|
Stolarczyk A, Stolarczyk M, Oleksy Ł, Maciąg GJ, Stępiński P, Szymczak J, Świercz M, Żarnovsky K, Mostowy M, Maciąg BM. Analysis of biomechanical gait parameters in patients after total hip replacement operated via anterolateral approach depending on size of the femoral head implant: retrospective matched-cohort study. Arch Orthop Trauma Surg 2022; 142:4015-4023. [PMID: 34837506 PMCID: PMC9596593 DOI: 10.1007/s00402-021-04264-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2021] [Accepted: 11/14/2021] [Indexed: 11/27/2022]
Abstract
INTRODUCTION Total hip replacement (THR) is considered one of the most effective medical procedures in treatment of osteoarthritis. Since its introduction, there has been a worldwide debate over proper implant selection in terms of size, bearing type and shape. Following study was designed to assess the importance of femoral head size in long-term follow-up. MATERIALS AND METHODS A cohort of 30 patients with primary end stage osteoarthritis who underwent total hip replacement was analysed retrospectively. A homogenous group was chosen with no major differences in BMI. Patients' gait parameters were measured in a biomechanics laboratory using the 3D BTS Smart system. WOMAC and VAS questionnaires were used to assess patient reported outcome. RESULTS The subgroup with larger implant head size had several outcomes significantly superior to the subgroup with standard head size and non-inferior to healthy hips. Following variables were measured during this study: time of support phase, time of swing phase, double support time, walking hip extension angle. CONCLUSIONS Use of larger sized femoral heads during THR gives better results in terms of gait pattern. Since restoring the gait pattern is one of the aspects of rehabilitation and returning to daily activities it seems to be an important observation.
Collapse
Affiliation(s)
- Artur Stolarczyk
- Department of Orthopedics and Rehabilitation, Medical University of Warsaw, Warsaw, Poland
| | - Magda Stolarczyk
- 3rd Clinic of Internal Medicine and Cardiology, Medical University of Warsaw, Warsaw, Poland
| | - Łukasz Oleksy
- Department of Orthopedics and Rehabilitation, Medical University of Warsaw, Warsaw, Poland
| | - Grzegorz J. Maciąg
- Department of Orthopedics and Rehabilitation, Medical University of Warsaw, Warsaw, Poland
| | - Piotr Stępiński
- Department of Orthopedics and Rehabilitation, Medical University of Warsaw, Warsaw, Poland
| | - Jakub Szymczak
- Department of Orthopedics and Rehabilitation, Medical University of Warsaw, Warsaw, Poland
| | - Maciej Świercz
- Department of Orthopedics and Rehabilitation, Medical University of Warsaw, Warsaw, Poland
| | - Krystian Żarnovsky
- Department of Orthopedics and Rehabilitation, Medical University of Warsaw, Warsaw, Poland
| | | | - Bartosz M. Maciąg
- Department of Orthopedics and Rehabilitation, Medical University of Warsaw, Warsaw, Poland
| |
Collapse
|
3
|
Murphy MP, Schneider AM, LeDuc RC, Killen CJ, Adams WH, Brown NM. A Multivariate Analysis to Predict Total Hip Arthroplasty Dislocation With Preoperative Diagnosis, Surgical Approach, Spinal Pathology, Cup Orientation, and Head Size. J Arthroplasty 2022; 37:168-175. [PMID: 34548193 DOI: 10.1016/j.arth.2021.08.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 08/18/2021] [Accepted: 08/29/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND There are several risk factors for dislocation after total hip arthroplasty (THA), but few studies include radiographic assessment of implants, with spine pathology and patient characteristics. This study estimates the rate of dislocation by patient gender, age, race/ethnicity, body mass index, Charlson Comorbidity Index, spine pathology, prior spine fusion, levels affected, radiographic Kellgren-Lawrence score of spine osteoarthritis, THA indication, surgical approach, and femoral head size. METHODS Seventy-six primary THA patients between January 2007 and 2020 with a dislocation were matched on age and gender to subjects without a known history of dislocation using a 2:1 allocation. Univariable and multivariable survival models that account for matched strata were used to estimate the rate of dislocation. RESULTS Median follow-up of patients at risk for dislocation was 26.48 months (95% confidence interval [CI] 23.75-36.40). On multivariable analysis, patients with an indication other than primary osteoarthritis were 3.69 (95% CI 2.22-6.13, P < .001) times more likely to dislocate than those with osteoarthritis. Patients with a spine pathology were also nominally more likely to dislocate (hazard ratio 1.76, 95% CI 0.97-3.18, P = .06), and patients receiving a posterior surgical approach were 2.74 (95% CI 1.11-6.76, P = .03) times more likely than those receiving a non-posterior approach to dislocate. CONCLUSION Patients with THA indication other than primary osteoarthritis and receiving a posterior surgical approach, and to a lesser degree spinal pathology, were identified as affecting the rate of dislocation. After correcting for other variables, femoral head size, cup orientation, and patient factors were not predictive. LEVEL OF EVIDENCE Level IV, case-control study.
Collapse
Affiliation(s)
- Michael P Murphy
- Loyola University Medical Center, Department of Orthopaedic Surgery and Rehabilitation, Maywood, IL
| | - Andrew M Schneider
- Loyola University Medical Center, Department of Orthopaedic Surgery and Rehabilitation, Maywood, IL
| | - Ryan C LeDuc
- Loyola University Medical Center, Department of Orthopaedic Surgery and Rehabilitation, Maywood, IL
| | - Cameron J Killen
- Loyola University Medical Center, Department of Orthopaedic Surgery and Rehabilitation, Maywood, IL
| | - William H Adams
- Loyola University Chicago, Department of Public Health Sciences, Maywood, IL
| | - Nicholas M Brown
- Loyola University Medical Center, Department of Orthopaedic Surgery and Rehabilitation, Maywood, IL
| |
Collapse
|
4
|
Abstract
Choice of articulating materials, head size and the design of the articulation will become decisive for the long-term performance of a total hip arthroplasty (THA) and especially in terms of risk for dislocation and wear-related problems. Here we account for common alternatives based on available studies and the evidence that can be derived from them.Metal or ceramic femoral heads articulating against a liner or cup made of highly cross-linked polyethylene and ceramic-on-ceramic articulations have about similar risk for complications leading to revision, whereas the performance of metal-on-metal articulations, especially with use of big heads, is inferior. The clinical significance of problems related to ceramic-on-ceramic articulations such as squeaking remains unclear. With use of current technology ceramic fractures are rare.Large femoral heads have the potential to increase the range of hip movement before impingement occurs and are therefore expected to reduce dislocation rates. On the other hand, issues related to bearing wear, corrosion at the taper-trunnion junction and groin pain may arise with larger heads and jeopardize the longevity of THA. Based on current knowledge, 32-mm heads seem to be optimal for metal-on-polyethylene bearings. Patients with ceramic-on-ceramic bearings may benefit from even larger heads such as 36 or 40 mm, but so far there are no long-term reports that confirm the safety of bearings larger than 36 mm.Assessment of lipped liners is difficult because randomized studies are lacking, but retrospective clinical studies and registry data seem to indicate that this liner modification will reduce the rate of dislocation or revision due to dislocation without clear evidence of clinically obvious problems due to neck-liner impingement.The majority of studies support the view that constrained liners and dual mobility cups (DMC) will reduce the risk of revision due to dislocation both in primary and revision THA, the latter gaining increasing popularity in some countries. Both these devices suffer from implant-specific problems, which seem to be more common for the constrained liner designs. The majority of studies of these implants suffer from various methodological problems, not least selection bias, which calls for randomized studies preferably in a multi-centre setting to obtain sufficient power. In the 2020s, the orthopaedic profession should place more effort on such studies, as has already been achieved within other medical specialties, to improve the level of evidence in the choice of articulation when performing one of the most common in-hospital surgical procedures in Europe. Cite this article: EFORT Open Rev 2020;5:763-775. DOI: 10.1302/2058-5241.5.200002.
Collapse
Affiliation(s)
- Georgios Tsikandylakis
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
- Region Västra Götaland, Sahlgrenska University Hospital, Department of Orthopaedics, Gothenburg, Sweden
| | - Soren Overgaard
- The Danish Hip Arthroplasty Register, Aarhus, Denmark
- Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark
- Institute of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Luigi Zagra
- Hip Department, IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
| | - Johan Kärrholm
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
- Region Västra Götaland, Sahlgrenska University Hospital, Department of Orthopaedics, Gothenburg, Sweden
- The Swedish Hip Arthroplasty Register, Gothenburg, Sweden
| |
Collapse
|
5
|
Abstract
The femoral head size influences dislocation, range of motion (ROM), functional outcome, wear, and survival after total hip arthroplasty (THA). These aspects of different head sizes with contemporary bearings in primary THA have been reviewed. Based on the existing evidence, for highly-cross-linked polyethylene (HXLPE) bearings, a 32 mm cobalt chromium (CoCr) or ceramic head appears to be a suitable choice. If a 36 mm head with HXLPE is desired, a ceramic head may be preferable over CoCr due to reduced risk of fretting and corrosion with the former. For ceramic-on-ceramic (CoC) bearings, head sizes >36 mm do not appear to provide any significant benefit over 36 mm heads. Also, large ceramic heads may lead to increased risk of squeaking. If non-cross-linked PE bearing is considered for use, it would be prudent to opt for <32 mm head size.
Collapse
Affiliation(s)
- Siddharth M Shah
- S L Raheja (A Fortis Associate) hospital, Mahim West, Mumbai, India
| |
Collapse
|
6
|
Tsikandylakis G, Mohaddes M, Cnudde P, Eskelinen A, Kärrholm J, Rolfson O. Head size in primary total hip arthroplasty. EFORT Open Rev 2018; 3:225-231. [PMID: 29951260 PMCID: PMC5994615 DOI: 10.1302/2058-5241.3.170061] [Citation(s) in RCA: 66] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
The use of larger femoral head size in total hip arthroplasty (THA) has increased during the past decade; 32 mm and 36 mm are the most commonly used femoral head sizes, as reported by several arthroplasty registries.The use of large femoral heads seems to be a trade-off between increased stability and decreased THA survivorship.We reviewed the literature, mainly focussing on the past 5 years, identifying benefits and complications associated with the trend of using larger femoral heads in THA.We found that there is no benefit in hip range of movement or hip function when head sizes > 36 mm are used.The risk of revision due to dislocation is lower for 36 mm or larger bearings compared with 28 mm or smaller and probably even with 32 mm.Volumetric wear and frictional torque are increased in bearings bigger than 32 mm compared with 32 mm or smaller in metal-on-cross-linked polyethylene (MoXLPE) THA, but not in ceramic-on-XLPE (CoXLPE).Long-term THA survivorship is improved for 32 mm MoXLPE bearings compared with both larger and smaller ones.We recommend a 32 mm femoral head if MoXLPE bearings are used. In hips operated on with larger bearings the use of ceramic heads on XLPE appears to be safer. Cite this article: EFORT Open Rev 2018;3 DOI: 10.1302/2058-5241.3.170061.
Collapse
Affiliation(s)
- Georgios Tsikandylakis
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden
| | - Maziar Mohaddes
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden
| | - Peter Cnudde
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden
- Department of Orthopaedics, Prince Philip Hospital, HDUHB, Wales
| | - Antti Eskelinen
- Coxa Hospital for Joint Replacement, Tampere, Finland
- Finnish Arthroplasty Register, Helsinki, Finland
| | - Johan Kärrholm
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden
| | - Ola Rolfson
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden
| |
Collapse
|
7
|
Ramkumar PN, Navarro SM, Haeberle HS, Chughtai M, Flynn ME, Mont MA. Social Media and Total Joint Arthroplasty: An Analysis of Patient Utilization on Instagram. J Arthroplasty 2017; 32:2694-2700. [PMID: 28456560 DOI: 10.1016/j.arth.2017.03.067] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2016] [Revised: 02/28/2017] [Accepted: 03/28/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The purpose of this study was to analyze the nature of shared content of total joint arthroplasty patients on Instagram. Specifically, we evaluated social media posts for: (1) perspective and timing; (2) tone; (3) focus (activities of daily living [ADLs], rehabilitation, return-to-work); and (4) the comparison between hip and knee arthroplasties. METHODS A search of the public Instagram domain was performed over a 6-month period. Total hip and knee arthroplasties (THA and TKA) were selected for the analysis using the following terms: "#totalhipreplacement," "#totalkneereplacement," and associated terms. 1287 individual public posts of human subjects were shared during the period. A categorical scoring system was utilized for media format (photo or video), time (preoperative, perioperative, or postoperative) period, tone (positive or negative), return-to-work, ADLs, rehabilitation, surgical site, radiograph image, satisfaction, and dissatisfaction. RESULTS Ninety-one percent of the posts were shared during the postoperative period. Ninety-three percent of posts had a positive tone. Thirty-four percent of posts focused on both ADLs and 33.8% on rehabilitation. TKA patients shared more about their surgical site (14.5% vs 3.3%, P < .001) and rehabilitation (58.9% vs 8.8%, P < .001) than THA patients, whereas THA patients shared more about ADLs than TKA patients (60.5% vs 7.6%, P < .001). CONCLUSION When sharing their experience on Instagram, arthroplasty patients did so with a positive tone, starting a week after surgery. TKA posts focused more on rehabilitation and wound healing than THA patients, whereas THA patients shared more posts on ADLs. The analysis of social media posts provides insight into what matters to patients after total joint arthroplasty.
Collapse
Affiliation(s)
- Prem N Ramkumar
- Department of Orthopedic Surgery, Cleveland Clinic, Cleveland, Ohio
| | - Sergio M Navarro
- Department of Orthopaedic Surgery, Baylor College of Medicine, Houston, Texas
| | - Heather S Haeberle
- Department of Orthopaedic Surgery, Baylor College of Medicine, Houston, Texas
| | - Morad Chughtai
- Department of Orthopedic Surgery, Cleveland Clinic, Cleveland, Ohio
| | - Megan E Flynn
- Department of Orthopedic Surgery, Cleveland Clinic, Cleveland, Ohio
| | - Michael A Mont
- Department of Orthopedic Surgery, Cleveland Clinic, Cleveland, Ohio
| |
Collapse
|
8
|
Femoral head diameter considerations for primary total hip arthroplasty. Orthop Traumatol Surg Res 2015; 101:S25-9. [PMID: 25596984 DOI: 10.1016/j.otsr.2014.07.026] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2014] [Revised: 05/07/2014] [Accepted: 07/08/2014] [Indexed: 02/02/2023]
Abstract
The configuration of total hip arthroplasty (THA) implants has constantly evolved since they were first introduced. One of the key components of THA design is the diameter of the prosthetic femoral head. It has been well established that the risk of dislocation is lower as the head diameter increases. But head diameter impacts other variables beyond joint stability: wear, cam-type impingement, range of motion, restoration of biomechanics, proprioception and groin pain. The introduction of highly cross-linked polyethylene and hard-on-hard bearings has allowed surgeons to implant large-diameter heads that almost completely eliminate the risk of dislocation. But as a result, cup liners have become thinner. With femoral head diameters up to 36 mm, the improvement in joint range of motion, delay in cam-type impingement and reduction in dislocation risk have been clearly demonstrated. Conversely, large-diameter heads do not provide any additional improvements. If an "ecologically sound" approach to hip replacement is embraced (e.g. keeping the native femoral head diameter), hip resurfacing with a metal-on-metal bearing must be carried out. The reliability of large-diameter femoral heads in the longer term is questionable. Large-diameter ceramic-on-ceramic bearings may be plagued by the same problems as metal-on-metal bearings: groin pain, squeaking, increased stiffness, irregular lubrication, acetabular loosening and notable friction at the Morse taper. These possibilities require us to be extra careful when using femoral heads with a diameter greater than 36 mm.
Collapse
|
9
|
Matsushita I, Morita Y, Ito Y, Motomura H, Kimura T. Long-term clinical and radiographic results of cementless total hip arthroplasty for patients with rheumatoid arthritis: minimal 10-year follow-up. Mod Rheumatol 2013; 24:281-4. [DOI: 10.3109/14397595.2013.843758] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
10
|
Bunn A, Colwell CW, D’Lima DD. Bony impingement limits design-related increases in hip range of motion. Clin Orthop Relat Res 2012; 470:418-27. [PMID: 21918798 PMCID: PMC3254736 DOI: 10.1007/s11999-011-2096-3] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Factors affecting risk for impingement and dislocation can be related to the patient, implant design, or surgeon. While these have been studied independently, the impact of each factor relative to the others is not known. QUESTIONS/PURPOSES We determined the effect of three implant design factors, prosthetic placement, and patient anatomy on subject-specific ROM. METHODS We virtually implanted hip geometry obtained from 16 CT scans using computer models of hip components with differences in head size, neck diameter, and neck-shaft angle. A contact detection model computed ROM before prosthetic or bony impingement. We correlated anatomic measurements from pelvic radiographs with ROM. RESULTS When we implanted the components for best fit to the subject's anatomy or in the recommended orientation of 45° abduction and 20° anteversion, ROM was greater than 110° of flexion, 30° of extension, 45° of adduction-abduction, and 40° of external rotation. Changes in head size, neck diameter, and neck-shaft angle generated small gains (3.6°-6°) in ROM when analyzed individually, but collectively, we noted a more substantial increase (10°-17°). Radiographic measurements correlated only moderately with hip flexion and abduction. CONCLUSIONS It is feasible to tailor implant placement to each patient to maximize bony coverage without compromising ROM. Once bony impingement becomes the restricting factor, further changes in implant design may not improve ROM. Radiographic measurements do not appear to have value in predicting ROM.
Collapse
Affiliation(s)
- Adam Bunn
- Shiley Center for Orthopaedic Research and Education at Scripps Clinic, 11025 North Torrey Pines Road, Suite 200, La Jolla, CA 92037 USA
| | - Clifford W. Colwell
- Shiley Center for Orthopaedic Research and Education at Scripps Clinic, 11025 North Torrey Pines Road, Suite 200, La Jolla, CA 92037 USA
| | - Darryl D. D’Lima
- Shiley Center for Orthopaedic Research and Education at Scripps Clinic, 11025 North Torrey Pines Road, Suite 200, La Jolla, CA 92037 USA
| |
Collapse
|
11
|
Malek IA, Hashmi M, Holland JP. Socio-economic impact of Birmingham hip resurfacing on patient employment after ten years. INTERNATIONAL ORTHOPAEDICS 2010; 35:1467-70. [PMID: 21113593 DOI: 10.1007/s00264-010-1168-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2010] [Revised: 11/04/2010] [Accepted: 11/05/2010] [Indexed: 10/18/2022]
Abstract
Birmingham hip resurfacing is an attractive option for treatment of arthritis in young and active patients. The aim of this study was to assess the socio-economic impact of Birmingham hip resurfacing on their employment and work intensity at ten years. A cohort of 90 consecutive patients with 100 Birmingham hip resurfacing, performed by single surgeon, were reviewed prospectively. The mean age was 51 years at surgery. Prospective review was undertaken from surgery until the tenth post-operative year. Overall, 90% of patients were in the same employment following surgery. Two patients who were employed before surgery were unemployed. Three patients had to decrease their work intensity but were still employed. Three out of five disabled patients regained employment following surgery. Seventy-eight patients were able to continue their employment with no or minimal restriction. Birmingham hip resurfacing allows the majority of patients to continue their same employment at similar intensity ten years following surgery.
Collapse
Affiliation(s)
- Ibrahim A Malek
- Department of Orthopaedics, Freeman Hospital, Newcastle Upon Tyne, UK.
| | | | | |
Collapse
|
12
|
Cinotti G, Lucioli N, Malagoli A, Calderoli C, Cassese F. Do large femoral heads reduce the risks of impingement in total hip arthroplasty with optimal and non-optimal cup positioning? INTERNATIONAL ORTHOPAEDICS 2010; 35:317-23. [PMID: 20157813 DOI: 10.1007/s00264-010-0954-3] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2009] [Revised: 01/06/2010] [Accepted: 01/06/2010] [Indexed: 11/29/2022]
Abstract
The purpose of this study was to assess whether large femoral heads (36-38 mm) improve the range of motion in total hip arthroplasty compared to standard (28-32 mm) femoral heads in the presence of optimal and non-optimal cup positioning. A mathematical model of the hip joint was generated by using a laser scan of a dried cadaveric hip. The range of motion was assessed with a cup inclination and anteversion of reference and with non-optimal cup positions. Large femoral heads increased the range of motion, compared to the 28-mm femoral head, in the presence of a hip prosthesis correctly implanted and even more so in the presence of non-optimal cup positioning. However, with respect to the 32-mm femoral head, large femoral heads showed limited benefits both in the presence of optimal and non-optimal cup positioning.
Collapse
|