1
|
Cimatti P, Del Piccolo N, Dallari B, Mazzotta A, Dallari D. Use of morselized bone allograft in revision hip arthroplasty for massive acetabular defect: A systematic review and meta-analysis. J Exp Orthop 2024; 11:e70091. [PMID: 39634575 PMCID: PMC11615971 DOI: 10.1002/jeo2.70091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2024] [Revised: 10/07/2024] [Accepted: 10/10/2024] [Indexed: 12/07/2024] Open
Abstract
Purpose Many treatment options are available for the revision of large acetabular defects. Debate continues as to which technique is most effective. This meta-analysis aimed to determine the rates of failure of acetabular bone defects Paprosky type III or American Academy of Orthopaedic types III-IV treated with morselized allograft in association with cemented cup or cementless cup or reinforcement devices. Methods The US National Library of Medicine (PubMed/MEDLINE), EMBASE and the Cochrane Database of Systematic Reviews were queried for publications from January 1980 to 1 April 2024 utilizing keywords pertinent to total hip arthroplasty (THA), acetabular impaction bone grafting and revision THA. The main outcome measure was the 9-year implant failure rate. Results Thirty-nine articles were eligible for inclusion in the current study. We found 41 treatment approaches that we grouped into three different treatment options: 1 = morselized allograft and cemented cup (10 studies); 2 =morselized allograft and cementless cup (nine studies); 3 = morselized allograft and device (22 studies). The overall implant failure rate was 2.1% (95% confidence interval [CI], 1.6%-2.8%) at a mean of 9.2 years. There was no significant difference in failure rates between different treatment options (1.6% [95% CI, 0.9%-2.6%]) for morselized allograft and cemented cup; 2.1% (95% CI, 1.4%-3.2%) for morselized allograft and cementless cup; 2.5% (95% CI, 1.7%-3.7%) for morselized allograft and device) between the three different types of treatment (heterogeneity between groups p = 0.351).It was determined that the number one cause of failure was aseptic loosening (80.5%), followed by infection (13.1%) and dislocation (6.4%). THA with reinforcement devices has a higher incidence of infection (3.6 vs. 0.7%, p = 0.001) and dislocation (1.4 vs. 0.6%, p = 0.010) than THA with a cemented cup. Conclusions The use of morselized allograft in hip revision of large acetabular defects has low implant failure rates, independently of the associated type of implant. Reinforcement devices increase the risk of re-revision for infection and dislocation. Level of Evidence Level III.
Collapse
Affiliation(s)
- Pietro Cimatti
- Reconstructive Orthopaedic Surgery Innovative Techniques—Musculoskeletal Tissue BankIRCCS Istituto Ortopedico RizzoliBolognaItaly
- Department of Surgical Sciences and Innovative TechnologiesUniversity of Bologna—Alma Mater StudiorumBolognaItaly
| | - Nicolandrea Del Piccolo
- Reconstructive Orthopaedic Surgery Innovative Techniques—Musculoskeletal Tissue BankIRCCS Istituto Ortopedico RizzoliBolognaItaly
| | - Benedetta Dallari
- Reconstructive Orthopaedic Surgery Innovative Techniques—Musculoskeletal Tissue BankIRCCS Istituto Ortopedico RizzoliBolognaItaly
| | - Alessandro Mazzotta
- Reconstructive Orthopaedic Surgery Innovative Techniques—Musculoskeletal Tissue BankIRCCS Istituto Ortopedico RizzoliBolognaItaly
| | - Dante Dallari
- Reconstructive Orthopaedic Surgery Innovative Techniques—Musculoskeletal Tissue BankIRCCS Istituto Ortopedico RizzoliBolognaItaly
| |
Collapse
|
2
|
Broekhuis D, Meurs WMH, Kaptein BL, Karunaratne S, Carey Smith RL, Sommerville S, Boyle R, Nelissen RGHH. High accuracy of positioning custom triflange acetabular components in tumour and total hip arthroplasty revision surgery. Bone Jt Open 2024; 5:260-268. [PMID: 38555947 PMCID: PMC10981996 DOI: 10.1302/2633-1462.54.bjo-2023-0185.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/02/2024] Open
Abstract
Aims Custom triflange acetabular components (CTACs) play an important role in reconstructive orthopaedic surgery, particularly in revision total hip arthroplasty (rTHA) and pelvic tumour resection procedures. Accurate CTAC positioning is essential to successful surgical outcomes. While prior studies have explored CTAC positioning in rTHA, research focusing on tumour cases and implant flange positioning precision remains limited. Additionally, the impact of intraoperative navigation on positioning accuracy warrants further investigation. This study assesses CTAC positioning accuracy in tumour resection and rTHA cases, focusing on the differences between preoperative planning and postoperative implant positions. Methods A multicentre observational cohort study in Australia between February 2017 and March 2021 included consecutive patients undergoing acetabular reconstruction with CTACs in rTHA (Paprosky 3A/3B defects) or tumour resection (including Enneking P2 peri-acetabular area). Of 103 eligible patients (104 hips), 34 patients (35 hips) were analyzed. Results CTAC positioning was generally accurate, with minor deviations in cup inclination (mean 2.7°; SD 2.84°), anteversion (mean 3.6°; SD 5.04°), and rotation (mean 2.1°; SD 2.47°). Deviation of the hip centre of rotation (COR) showed a mean vector length of 5.9 mm (SD 7.24). Flange positions showed small deviations, with the ischial flange exhibiting the largest deviation (mean vector length of 7.0 mm; SD 8.65). Overall, 83% of the implants were accurately positioned, with 17% exceeding malpositioning thresholds. CTACs used in tumour resections exhibited higher positioning accuracy than rTHA cases, with significant differences in inclination (1.5° for tumour vs 3.4° for rTHA) and rotation (1.3° for tumour vs 2.4° for rTHA). The use of intraoperative navigation appeared to enhance positioning accuracy, but this did not reach statistical significance. Conclusion This study demonstrates favourable CTAC positioning accuracy, with potential for improved accuracy through intraoperative navigation. Further research is needed to understand the implications of positioning accuracy on implant performance and long-term survival.
Collapse
Affiliation(s)
- Demien Broekhuis
- Department of Orthopaedic Surgery, Leiden University Medical Centre, Leiden, Netherlands
| | - Willemijne M. H. Meurs
- Department of Orthopaedic Surgery, Leiden University Medical Centre, Leiden, Netherlands
| | - Bart L. Kaptein
- Department of Orthopaedic Surgery, Leiden University Medical Centre, Leiden, Netherlands
| | - Sascha Karunaratne
- Surgical Outcomes Research Centre (SOuRCe), Royal Prince Alfred Hospital, Sydney, Australia
| | | | - Scott Sommerville
- Department of Orthopaedic Surgery, Princess Alexandra Hospital, Brisbane, Australia
| | - Richard Boyle
- Department of Orthopaedic Surgery, Royal Prince Alfred Hospital, Sydney, Australia
| | - Rob G. H. H. Nelissen
- Department of Orthopaedic Surgery, Leiden University Medical Centre, Leiden, Netherlands
| |
Collapse
|
3
|
Álvarez Valdivielso A, Akkaya M, Mau H, Luo TD, Gehrke T, Citak M. Survival analysis of 3D printed acetabular implants in revision total hip arthroplasty associated with severe pelvic discontinuities. Technol Health Care 2024; 32:3783-3792. [PMID: 38427516 DOI: 10.3233/thc-231647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/03/2024]
Abstract
BACKGROUND Surgeons still face difficulties when performing aseptic acetabular revision on patients with extensive defects. Advances in three-dimensional printing technology (3DP) have afforded to the surgeons to create a patient-specific implant matching the morphology and topography of the defect. OBJECTIVE The aim of the current research was to determine the survivorship in the treatment of acetabular bone defects with pelvic discontinuity (PD). METHODS In order to reconstruct Paprosky type III defects with PD, twenty-three patients underwent revision total hip arthroplasty (THA) utilizing 3D-printed implants (Mobelife). The primary outcomes were the implant-associated failure rate correlated with survivorship. As secondary variables, complications and the effect of age, sex, comorbidities, history of infections and the presence of other lower limb arthroplasties on a new revision were analyzed. RESULTS Patients were followed out to a mean of 67.22 ± 39.44 months (range, 0.9-127 months). Mobelife implant mean survival was 102.57 ± 9.90 months (95% CI 83.17-121.96). The cohort's implant one-year survival rate was 87%; at ten years, it dropped to 78.3%. There were four revisions: three due to periprosthetic joint infection (PJI) and one case due to aseptic loosening. Cox regression analysis did not identify any variable as predictor of failure. CONCLUSION The use of 3DP patient-specific acetabular components has shown encouraging results and it is a viable treatment option for addressing acetabular defects with combined PD in aseptic THA revision.
Collapse
Affiliation(s)
- Ainhoa Álvarez Valdivielso
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- Department of Traumatology and Orthopaedic Surgery, Hospital Universitario Son Espases, Palma de Mallorca, Spain
| | - Mustafa Akkaya
- Ankara Yildirim Beyazit University, Ankara City Hospital, Ankara, Turkey
| | - Hans Mau
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
| | - T David Luo
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- Orthopaedics Northeast, Fort Wayne, IN, USA
| | - Thorsten Gehrke
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
| | - Mustafa Citak
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
| |
Collapse
|
4
|
Meding JB, Meding LK. Custom Triflange Acetabular Implants: Average 10-year follow-up. J Arthroplasty 2023:S0883-5403(23)00263-2. [PMID: 36958713 DOI: 10.1016/j.arth.2023.03.035] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 03/06/2023] [Accepted: 03/13/2023] [Indexed: 03/25/2023] Open
Abstract
INTRODUCTION Acetabular reconstruction options in the setting of substantial bone deficiency (Paprosky 3A and 3B) remain limited. Custom triflange acetabular implants are one choice for this challenging problem. However, few studies have reported on survivorship beyond 3 to 5 years. The purpose of this study was to report our 6 to 13-year clinical results using these custom-made acetabular components. METHODS Between 2008 and March 2015, 42 revision total hip arthroplasties (THAs) (41 patients) were performed at our institution with a custom tri-flange acetabular component. All revisions involved either Paprosky 3A or 3B acetabular defects. Two patients died before the five-year follow-up. Harris Hip Scores were obtained at 6 months, 1 year, and every 2 to 3 years thereafter. The average follow-up in the remaining 40 revision THAs was 10 years (range, 6 to 13 years). RESULTS At final follow-up, the mean Harris score was 74 points. There were two deep infections (5%). One custom implant was removed for deep infection (2.5%). Three hips (7.5%) experienced a total of 4 dislocations necessitation revision in one hip (femoral component only). One custom implant was judged to be loose. There were no cases of femoral nerve palsy. At final follow-up, 38 (95%) of the custom acetabular implants were considered radiographically stable. CONCLUSION Instability and infection remain a major concern and cause of failure in these complex reconstructions. At an average follow-up of 10 years, however, custom triflange acetabular implants appear to work at least as well as jumbo cups and cup/cage constructs in the setting of extensive erosion of acetabular bone.
Collapse
Affiliation(s)
- John B Meding
- The Center for Hip and Knee Surgery, Mooresville, Indiana
| | | |
Collapse
|
5
|
Giachino M, Aprato A, Limone B, Ciccone G, Rosso T, Massè A. Impact of three-dimensional printed planning in Paprosky III acetabular defects: a case-control and cost-comparison analysis. INTERNATIONAL ORTHOPAEDICS 2023; 47:1465-1472. [PMID: 36930258 DOI: 10.1007/s00264-023-05763-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Accepted: 03/04/2023] [Indexed: 03/18/2023]
Abstract
PURPOSE The main challenges in revision total hip arthroplasty (rTHA) are the treatment of the bone loss and the pre-operative planning. 3D-printed models may enhance pre-operative planning. The aim of the study is to compare the intra- and peri-operative results and costs for Paprosky type 3 rTHAs planned with 3D-printed models to ones accomplished with the conventional imaging techniques (X-rays and CT scan). METHODS Seventy-two patients with Paprosky type 3 defect underwent rTHA between 2014 and 2021. Fifty-two patients were treated with standard planning and 20 were planned on 3D-printed models. Surgical time, intra-operative blood loss, number of transfused blood units, number of post-operative days of hospitalization, and use of acetabular rings were compared between the two groups. A costs comparison was also performed. RESULTS The 3D-printed group showed reduced operative time (101.8 min (SD 27.7) vs. 146.1 min (SD 49.5), p < 0.001) and total days of hospitalization (9.3 days (SD 3.01) vs. 12.3 days (SD 6.01), p = 0.009). The cost of the procedures was significantly lower than the control group, with an adjusted difference of 4183 euros (p = 0.004). No significant differences were found for the number of total transfused blood units and blood loss and the number of acetabular rings. CONCLUSION The use of 3D-printed models led to a meaningful cost saving. The 3D-printed pre-operative planning for complex rTHAs seems to be effective in reducing operating time, hospital stay and overall costs.
Collapse
Affiliation(s)
- M Giachino
- Department of Traumatology Orthopaedic and Occupational Medicine, University of Study of Turin, Medicine School (CTO Hospital), Turin, Italy.
| | - A Aprato
- Department of Traumatology Orthopaedic and Occupational Medicine, University of Study of Turin, Medicine School (CTO Hospital), Turin, Italy
| | - B Limone
- Department of Traumatology Orthopaedic and Occupational Medicine, University of Study of Turin, Medicine School (CTO Hospital), Turin, Italy
| | - G Ciccone
- Clinical Epidemiology Unit, University of Study of Turin, Turin, Italy
| | - T Rosso
- Clinical Epidemiology Unit, University of Study of Turin, Turin, Italy
| | - A Massè
- Department of Traumatology Orthopaedic and Occupational Medicine, University of Study of Turin, Medicine School (CTO Hospital), Turin, Italy
| |
Collapse
|
6
|
Metal Augments Used in Revision Hip Arthroplasty: A Systematic Review and Single-Arm Meta-Analysis. J Arthroplasty 2023; 38:389-396.e1. [PMID: 35964855 DOI: 10.1016/j.arth.2022.08.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Revised: 08/05/2022] [Accepted: 08/07/2022] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND Porous metal augments are used in complex hip arthroplasty; however, few studies have assessed their efficacy and safety. This systematic review analyzed the use of augments in revision hip arthroplasty and summarized the clinical research findings. METHODS We used combinations of "revision," "replacement," "arthroplasty," "augment," "acetabular," and "hip" to search PubMed, Web of Science, EMBASE, Cochrane Library databases, and clinical trial registration platform "Clinicaltrials" for relevant literature. The functional score, restoration of hip center of rotation, revision of implants, and complications were analyzed. Patients were divided into 3 subgroups according to the mean follow-up period. Overall, 19 reports involving 647 patients (655 hips) were selected. The mean age at the time of surgery was 63 years (range, 24-106) and the mean follow-up duration was 66 months (range, 11-204). RESULTS Harris Hip Score increased from approximately a mean of 40 points preoperatively to a mean of 84 points postoperatively. The vertical distance between hip center of rotation and teardrop was restored from a preoperative distance of 41.9 to 21.7 mm postoperatively. The overall acetabular revision rate was 4.7%, and the incidence of complications was 8.2%. There were significant differences in the reoperation, acetabular revision, and complication rates among the subgroups. CONCLUSION Metal augments used in revision hip arthroplasty are a safe and effective treatment option to correct acetabular defects.
Collapse
|
7
|
Sculco PK, Wright T, Malahias MA, Gu A, Bostrom M, Haddad F, Jerabek S, Bolognesi M, Fehring T, Gonzalez DellaValle A, Jiranek W, Walter W, Paprosky W, Garbuz D, Sculco T, Abdel M, Boettner F, Benazzo F, Buttaro M, Choi D, Engh CA, Garcia-Cimbrelo E, Garcia-Rey E, Gehrke T, Griffin WL, Hansen E, Hozack WJ, Jones S, Lee GC, Lipman J, Manktelow A, McLaren AC, Nelissen R, O’Hara L, Perka C, Sporer S. The Diagnosis and Treatment of Acetabular Bone Loss in Revision Hip Arthroplasty: An International Consensus Symposium. HSS J 2022; 18:8-41. [PMID: 35082557 PMCID: PMC8753540 DOI: 10.1177/15563316211034850] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Revised: 07/07/2021] [Accepted: 07/07/2021] [Indexed: 11/21/2022]
Abstract
Despite growing evidence supporting the evaluation, classification, and treatment of acetabular bone loss in revision hip replacement, advancements have not been systematically incorporated into a single document, and therefore, a comprehensive review of the treatment of severe acetabular bone loss is needed. The Stavros Niarchos Foundation Complex Joint Reconstruction Center at Hospital for Special Surgery held an Acetabular Bone Loss Symposium on June 21, 2019, to answer the following questions: What are the trends, emerging technologies, and areas of future research related to the evaluation and management of acetabular bone loss in revision hip replacement? What constitutes the optimal workup and management strategies for acetabular bone loss? The 36 international experts convened were divided into groups, each assigned to discuss 1 of 4 topics: (1) preoperative planning and postoperative assessment; (2) implant selection, management of osteolysis, and management of massive bone loss; (3) the treatment challenges of pelvic discontinuity, periprosthetic joint infection, instability, and poor bone biology; and (4) the principles of reconstruction and classification of acetabular bone loss. Each group came to consensus, when possible, based on an extensive literature review. This document provides an overview of these 4 areas, the consensus each group arrived at, and directions for future research.
Collapse
Affiliation(s)
- Peter K. Sculco
- Hospital for Special Surgery, New York, NY, USA,Peter K. Sculco, MD, Hospital for Special Surgery, 535 E. 70th St., New York, NY 10021, USA.
| | | | | | - Alexander Gu
- George Washington University School of Medicine & Health Sciences, Washington, DC, USA
| | | | - Fares Haddad
- University College London Hospitals NHS Foundation Trust and Institute of Sport, Exercise & Health, London, UK
| | | | | | | | | | | | - William Walter
- Royal North Shore Hospital, St. Leonards, NSW, Australia
| | - Wayne Paprosky
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Donald Garbuz
- Department of Orthopaedics, The University of British Columbia, Vancouver, BC, Canada
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Fröschen FS, Randau TM, Gravius N, Wirtz DC, Gravius S, Walter SG. Risk factors for implant failure of custom-made acetabular implants in patients with Paprosky III acetabular bone loss and combined pelvic discontinuity. Technol Health Care 2021; 30:703-711. [PMID: 34366301 DOI: 10.3233/thc-202236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Severe acetabular bone loss in revision total hip arthroplasty (RTHA), both with or without pelvic discontinuity, remains a great challenge in orthopaedic surgery. OBJECTIVE The aim of this study was to evaluate risk factors for failure of custom-made acetabular implants in RTHA. METHODS Seventy patients with severe acetabular bone loss (Paprosky Type III) and pelvic discontinuity, who required RTHA, were included in our study. All prostheses were constructed based on a thin-layer computed-tomography (CT) scan of the pelvis. The treatment was considered unsuccessful in the event of periprosthetic joint infection (PJI) or aseptic loosening (AL) with need for explantation of the custom-made acetabular implant. RESULTS The average follow-up was 41.9 ± 34.8 months (range 1.5-120). Implant survival at last follow-up was 75.7% (53 of 70). Explantation was necessary in 17 cases (15 PJI; 2 AL). Previous PJI as reason for RTHA (p= 0.025; OR 3.56 (95% CI: 1.14; 11.21)), additional revision of femoral components (p= 0.003; OR 8.4 (95% CI: 1.75; 40.42)), rheumatoid disease (p= 0.039; OR 3.43 (95% CI: 1.01; 11.40)), elevated preoperative CRP > 15.2 mg/l (p= 0.015; AUC: 0.7) and preoperative haemoglobin < 10.05 (p= 0.022; AUC: 0.69) were statistically significant risk factors associated with treatment failure. Age and BMI were not statistically significant contributing to implant failure. CONCLUSION Risk factors for treatment failure were a previous PJI, additional revision of femoral component, rheumatoid disease, elevated preoperative CRP and low preoperative haemoglobin. Awareness of these risk factors will help to improve future treatment standards.
Collapse
Affiliation(s)
- Frank S Fröschen
- Department of Orthopaedic Surgery and Traumatology, University Hospital Bonn, Germany
| | - Thomas M Randau
- Department of Orthopaedic Surgery and Traumatology, University Hospital Bonn, Germany
| | - Nadine Gravius
- Department of Orthopaedic Surgery and Traumatology, University Hospital Mannheim, Germany
| | - Dieter C Wirtz
- Department of Orthopaedic Surgery and Traumatology, University Hospital Bonn, Germany
| | - Sascha Gravius
- Department of Orthopaedic Surgery and Traumatology, University Hospital Mannheim, Germany
| | - Sebastian G Walter
- Department of Orthopaedic Surgery and Traumatology, University Hospital Cologne, Germany
| |
Collapse
|
9
|
Siegel MA, Patetta MJ, Chen JY, Barragan Echenique DM, Gonzalez MH. The use of a triflange salvage system for catastrophic pelvic osteolysis after failed total hip arthroplasty. J Orthop 2021; 25:16-22. [PMID: 33897135 DOI: 10.1016/j.jor.2021.03.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 03/28/2021] [Indexed: 10/21/2022] Open
Abstract
Introduction The custom triflange acetabular implant (CTAI) has been described to address catastrophic pelvic osteolysis, but long-term outcome data is scarce. Methods Revision-free survivorship after revision THA with a CTAI was retrospectively reviewed in seven patients. Results Mean and median follow-up time were 7.39 (1.61-16.8) years and 7.50 years, respectively. Revision-free survivorship was 85.7% (6/7). One patient underwent revision for recurrent dislocations. All patients were able to ambulate at recent follow-up- 2/7 without assistance. Conclusions The CTAI is a viable option for patients with catastrophic pelvic osteolysis. There is a high complication rate, but the incidence of revision is low.
Collapse
Affiliation(s)
- Matthew A Siegel
- University of Illinois College of Medicine at Chicago, Department of Orthopaedic Surgery, USA
| | - Michael J Patetta
- University of Illinois College of Medicine at Chicago, Department of Orthopaedic Surgery, USA
| | - Jason Y Chen
- University of Illinois College of Medicine at Chicago, Department of Orthopaedic Surgery, USA
| | | | - Mark H Gonzalez
- University of Illinois College of Medicine at Chicago, Department of Orthopaedic Surgery, USA
| |
Collapse
|
10
|
Changjun C, Xin Z, Mohammed A, Liyile C, Yue L, Pengde K. Survivorship and clinical outcomes of ‘cup–cage’ reconstruction in revision of hip arthroplasty for chronic pelvic discontinuity: A systematic review. Surgeon 2021; 19:e475-e484. [DOI: 10.1016/j.surge.2020.11.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Revised: 11/13/2020] [Accepted: 11/26/2020] [Indexed: 12/27/2022]
|
11
|
Frenzel S, Horas K, Rak D, Boelch SP, Rudert M, Holzapfel BM. Acetabular Revision With Intramedullary and Extramedullary Iliac Fixation for Pelvic Discontinuity. J Arthroplasty 2020; 35:3679-3685.e1. [PMID: 32694031 DOI: 10.1016/j.arth.2020.06.067] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Revised: 06/02/2020] [Accepted: 06/23/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Parallel to the increase in revision hip procedures surgeons face more and more complex anatomical challenges with pelvic discontinuity (PD) being one of the worst-case scenarios. Here we report on our clinical results using an asymmetric acetabular component for the treatment of PD. The implant is armed in a monoblock fashion with an extramedullary iliac flange and provides the possibility to augment it with an intramedullary iliac press-fit stem. METHODS In a single-center retrospective cohort study we analyzed prospectively collected data of 49 patients (35 female, 14 male) suffering from unilateral periprosthetic PD treated with an asymmetric acetabular component between 2009 and 2017. The mean follow-up was 71 months (21-114). Complications were documented and radiographic and functional outcomes were assessed. RESULTS Kaplan-Meier analysis revealed a 5-year implant survival of 91% (confidence interval 77%-96%). The 5-year survival with revision for any cause was 87% (CI 74%-94%). The overall revision rate was 16% (n = 8). Two patients required acetabular component revision due to aseptic loosening. Four patients (8%) suffered from periprosthetic infection: one patient was treated with a 2-stage revision, and another one with resection arthroplasty. The other 2 patients were treated with debridement, irrigation, and exchange of the mobile parts. Of 6 patients (12%) suffering from hip dislocation, 2 required implantation of a dual mobility acetabular component. The mean Harris Hip Score improved from 41 preoperatively to 79 at the latest follow-up (P < .001). CONCLUSION Our findings demonstrate that an asymmetric acetabular component with extramedullary and optional intramedullary iliac fixation is a reliable and safe treatment method for periprosthetic PD resulting in good clinical and radiographic mid-term results.
Collapse
Affiliation(s)
- Stephan Frenzel
- Department of Orthopaedic Surgery, University of Wuerzburg, Wuerzburg, Germany; Department of Orthopaedics and Trauma Surgery, Medical University Vienna, Vienna General Hospital, Vienna, Austria
| | - Konstantin Horas
- Department of Orthopaedic Surgery, University of Wuerzburg, Wuerzburg, Germany
| | - Dominik Rak
- Department of Orthopaedic Surgery, University of Wuerzburg, Wuerzburg, Germany
| | | | - Maximilian Rudert
- Department of Orthopaedic Surgery, University of Wuerzburg, Wuerzburg, Germany
| | - Boris Michael Holzapfel
- Department of Orthopaedic Surgery, University of Wuerzburg, Wuerzburg, Germany; Regenerative Medicine, Institute of Health and Biomedical Innovation, Queensland University of Technology (QUT), Brisbane, Queensland, Australia
| |
Collapse
|
12
|
Fröschen FS, Randau TM, Hischebeth GTR, Gravius N, Wirtz DC, Gravius S, Walter SG. Outcome of repeated multi-stage arthroplasty with custom-made acetabular implants in patients with severe acetabular bone loss: a case series. Hip Int 2020; 30:64-71. [PMID: 32907426 DOI: 10.1177/1120700020928247] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Failed reconstruction in cases of severe acetabular bone loss, with or without pelvic discontinuity, in revision total hip arthroplasty (rTHA) remains a great challenge in orthopaedic surgery. The aim of this study was to describe the outcome of a "second" rTHA with "custom-made acetabular components (CMACs)" after a previously failed reconstruction with CMACs. METHODS 4 patients with severe acetabular bone loss (Paprosky Type IIIB), who required a second rTHA after a previously failed reconstruction with CMAC, due to prosthetic joint infection (PJI), were included in our retrospective study. All prostheses had been constructed on the basis of thin-layer computed-tomography scans of the pelvis. The second rTHA was considered unsuccessful in the event of PJI or aseptic loosening (AL) with need for renewed CMAC explantation. RESULTS The treatment success rate after second rTHA with a CMAC was 50% (2 of 4). In the successful cases, the visual analogue scale (VAS) score and Harris Hip Score (HHS) after the second rTHA (VAS range 2-4; HHS range 45-58 points) did not differ from those after the first rTHA, before onset of symptoms (VAS: range 2-4; HHS: range 47-55 points). In the failed cases, the second CMACs needed to be explanted due to PJI, with renewed detection of previous pathogens. Patients with treatment failure of the second CMAC had required a higher number of revision surgeries after explantation of the first CMAC than patients with a successful outcome. CONCLUSIONS In patients with severe acetabular bone loss and previously failed rTHA with CMACs, repeat rTHA with a CMAC may be a solid treatment option for patients with an "uncomplicated" multi-stage procedure, i.e., without persisting infection after explantation of the original CMAC. While the outcome in terms of clinical function does not appear negatively affected by such a "second attempt," the complication rate and risk of reinfection, nonetheless, is high.
Collapse
Affiliation(s)
- Frank S Fröschen
- Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| | - Thomas M Randau
- Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| | - Gunnar T R Hischebeth
- Institute of Medical Microbiology, Immunology and Parasitology, University Hospital Bonn, Bonn, Germany
| | - Nadine Gravius
- Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| | - Dieter C Wirtz
- Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| | - Sascha Gravius
- Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany.,Orthopaedic and Trauma Surgery Centre, University Hospital Mannheim, Medical Faculty Mannheim of the University of Heidelberg, Mannheim, Germany
| | - Sebastian G Walter
- Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| |
Collapse
|
13
|
von Lewinski G. [Custom-made acetabular implants in revision total hip arthroplasty]. DER ORTHOPADE 2020; 49:417-423. [PMID: 32266432 DOI: 10.1007/s00132-020-03909-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
BACKGROUND Management of acetabular bone loss is a demanding problem in revision total hip arthroplasty. OBJECTIVES The aim of this review is to introduce and discuss the results and the advantages and disadvantages of custom-made implants as a treatment option for severe acetabular bone defects. MATERIALS AND METHODS A selective review of the existing literature of custom made acetabular implants was performed on PubMed. RESULTS Studies showed good clinical and radiological outcomes of custom made acetabular implants and a survival rate of more than 90%. CONCLUSION Custom-made acetabular implants are a reliable treatment option for severe acetabular defects and allow the reconstruction of the centre of rotation of the hip. The costs of these implants are high and planning is time consuming.
Collapse
Affiliation(s)
- Gabriela von Lewinski
- Klinik für Unfallchirurgie, Orthopädie und Plastische Chirurgie, Universitätsmedizin Göttingen, Robert-Koch-Str. 40, 37099, Göttingen, Deutschland.
| |
Collapse
|
14
|
Malahias MA, Ma QL, Gu A, Ward SE, Alexiades MM, Sculco PK. Outcomes of Acetabular Reconstructions for the Management of Chronic Pelvic Discontinuity: A Systematic Review. J Arthroplasty 2020; 35:1145-1153.e2. [PMID: 31784362 DOI: 10.1016/j.arth.2019.10.057] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2019] [Revised: 10/11/2019] [Accepted: 10/29/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND A number of articles have been published reporting on the clinical outcomes of various acetabular reconstructions for the management of chronic pelvic discontinuity (PD). However, no systematic review of the literature has been published to date comparing the outcome and complications of different approaches to reconstruction. METHODS The US National Library of Medicine (PubMed/MEDLINE) and EMBASE were queried for publications from January 1980 to January 2019 using keywords pertinent to total hip arthroplasty, PD, acetabular dissociation, clinical or functional outcomes, and revision total hip arthroplasty or postoperative complications. RESULTS Overall, 18 articles were included in this analysis (569 cases with chronic PD). The overall survival rate of the acetabular components used for the treatment of chronic PD was 84.7% (482 of 569 cases) at mid-term follow-up, whereas the most common reasons for revision were aseptic loosening (54 of 569 hips; 9.5%), dislocations (45 of 569 hips; 7.9%), periprosthetic joint infection (30 of 569 hips; 5.3%), and periprosthetic fractures (11 of 569 hips; 1.9%). Both pelvic distraction technique (combined with highly porous shells) and custom triflanges resulted in less than 5% failure rates (96.2% and 95.8%, respectively) at final follow-up. Also, highly effective in the treatment of PD were cup-cages and highly porous shells with and/or without augments with 92% survivorship free of revision for aseptic loosening for both reconstruction methods. Inferior outcomes were reported for conventional cementless shells combined with acetabular plates (72.7%) as well as ilioischial cages and reconstruction rings (66.7% and 60.6% survivorship, respectively). CONCLUSION The current literature contains moderate quality evidence in support of the use of custom triflange implants and pelvic distraction techniques for the treatment of chronic PD, with a less than 5% all-cause revision rate and low complication rates at mean mid-term follow-up. Cup-cages and highly porous shells with or without augments could also be considered for the treatment of PD because both resulted in greater than 90% survival rates. Finally, there is still no consensus regarding the impact of different types of acetabular reconstruction methods on optimizing the healing potential of PD, and further studies are required in this area to better understand the influence of PD healing on construct survivorship and functional outcomes with each reconstruction method.
Collapse
Affiliation(s)
- Michael-Alexander Malahias
- The Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY
| | - Qian-Li Ma
- The Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY; Department of Orthopedic Surgery, Fuzhou Second Hospital affiliated to Xiamen University, Fuzhou, Fujian, China
| | - Alex Gu
- The Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY
| | - Sarah E Ward
- Division of Orthopaedic Surgery, St. Michael's Hospital, Toronto, Ontario, Canada
| | - Michael M Alexiades
- Department of Orthopaedics, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY
| | - Peter K Sculco
- The Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY
| |
Collapse
|
15
|
Chiarlone F, Zanirato A, Cavagnaro L, Alessio-Mazzola M, Felli L, Burastero G. Acetabular custom-made implants for severe acetabular bone defect in revision total hip arthroplasty: a systematic review of the literature. Arch Orthop Trauma Surg 2020; 140:415-424. [PMID: 31960168 DOI: 10.1007/s00402-020-03334-5] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Indexed: 01/21/2023]
Abstract
PURPOSE The management of acetabular bone loss is a challenging problem in revision total hip arthroplasty (rTHA). The aim of this systematic review is to summarize and critically analyze indications, complications, clinical and radiological outcomes of custom-made acetabular components in rTHA. METHODS A systematic review of English literature was performed on Medline. Retrospective or prospective studies with minimum 2 years of follow-up (FU) were included. The PRISMA 2009 flowchart and checklist were considered to edit the review. Rates of intra- or post-operative complications, aseptic loosening (AL), periprosthetic joint infection (PJI), reoperations and re-revisions rates were extrapolated. RESULTS 18 articles with a level of evidence of IV were included. Six hundred and thirty-four acetabular custom components (627 patients) with a mean FU of 58.6 ± 29.8 months were analyzed. The studies showed good clinical and functional outcomes. Custom-made acetabular components allowed a stable fixation with 94.0 ± 5.0% survival rate. The estimated rate of re-operations and re-revisions were 19.3 ± 17.3% and 5.2 ± 4.7%, respectively. The incidence of PJI was 4.0 ± 3.9%. CONCLUSIONS The acetabular custom-made implants represent a reliable solution for pelvic discontinuity and particular cases of bone loss classified as Paprosky Type IIIA-B or type III-IV according to American Academy of Orthopaedic Surgeons system where the feature of the defect cannot be handled with standard implants. This strategy allows to fit the implant to the residual host bone, bypassing the bony deficiency and restoring hip biomechanics. Satisfactory clinical and radiological outcomes at mid-term follow-up are reported in literature.
Collapse
Affiliation(s)
- Francesco Chiarlone
- Clinica Ortopedica, Ospedale Policlinico San Martino, Largo Rosanna Benzi 10, 16132, Genoa, GE, Italy
| | - Andrea Zanirato
- Clinica Ortopedica, Ospedale Policlinico San Martino, Largo Rosanna Benzi 10, 16132, Genoa, GE, Italy.
| | - Luca Cavagnaro
- Clinic Ortopedia e Traumatologia 2, Joint Replacement Unit, Ospedale Santa Corona, Viale 25 Aprile, 38, 17027, Pietra Ligure, SV, Italy
| | - Mattia Alessio-Mazzola
- Clinica Ortopedica, Ospedale Policlinico San Martino, Largo Rosanna Benzi 10, 16132, Genoa, GE, Italy
| | - Lamberto Felli
- Clinica Ortopedica, Ospedale Policlinico San Martino, Largo Rosanna Benzi 10, 16132, Genoa, GE, Italy
| | - Giorgio Burastero
- Clinic Ortopedia e Traumatologia 2, Joint Replacement Unit, Ospedale Santa Corona, Viale 25 Aprile, 38, 17027, Pietra Ligure, SV, Italy
| |
Collapse
|
16
|
Monoflanged Custom-Made Acetabular Components Promote Biomechanical Restoration of Severe Acetabular Bone Defects by Metallic Defect Reconstruction. J Arthroplasty 2020; 35:831-835. [PMID: 31735489 DOI: 10.1016/j.arth.2019.10.040] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 10/05/2019] [Accepted: 10/21/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Custom-made acetabular components (CMAC) are one established method to address severe acetabular bone defects. Monoflanged CMAC may represent an advantageous alternative to establish triflanged CMAC as they promote better primary stability through metallic defect reconstruction and thus anatomic restoration of the center of rotation (COR). METHODS Fifty-eight consecutive (21 triflanged and 37 monoflanged) CMAC were evaluated for overall survival, reasons for revision, radiological restoration of COR, and clinical outcome parameters. RESULTS There were no significant differences between both design types regarding overall survival, revision rates, Harris Hip Score, or visual analog scale (pain) score at latest follow-up (mean, 56.3 ± 28.7 months). Triflanged CMAC showed a significant lateralization (P ≤ .001) and cranialization (P = .003) of the COR compared to the contralateral side. Monoflanged CMAC restored the anatomic COR. Reasons for revision surgery and explantation were periprosthetic joint infection (n = 12) and aseptic loosening (n = 2) without significant differences between both groups. CONCLUSION Monoflanged CMAC demonstrate similar clinical outcome parameters and survival rates as triflanged CMAC but superior biomechanical features and represent therefore a solid alternative treatment option and implant design.
Collapse
|
17
|
Mid-term results after revision total hip arthroplasty with custom-made acetabular implants in patients with Paprosky III acetabular bone loss. Arch Orthop Trauma Surg 2020; 140:263-273. [PMID: 31820093 DOI: 10.1007/s00402-019-03318-0] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Indexed: 12/16/2022]
Abstract
INTRODUCTION Severe acetabular bone loss, both with or without pelvic discontinuity, remains a challenge in revision total hip arthroplasty (RTHA). The goal of our study was to evaluate the mid-term results for consecutive patients with Paprosky III acetabular bone loss with or without pelvic discontinuity who needed RTHA with custom-made acetabular implants and to compare the results to those of other studies. MATERIALS AND METHODS Sixty-eight (68) patients with severe acetabular bone loss (Paprosky Type IIIa and IIIb), who required RTHA, were included in our study. All prostheses were constructed on the basis of thin-layer computed tomography (CT) scans of the pelvis. The visual analogue scale (VAS), Harrison hip score (HHS), and clinical and radiographic follow-up assessments were used to evaluate the outcome. RESULTS The average follow-up time was 43 months (range 1-120 months). Implant survival at last follow-up was 75% (51 of 68). Kaplan-Meier survival analysis, with explantation as the endpoint, revealed survival rates of 82.7% (3 years) and 77% (5 years). Patients with revision of the acetabular component only had a significant higher survival rate (p 0.012). Overall revision rate was 36.7%. Reinfection rate was 34.4%. Complications included 15 (22%) periprosthetic joint infections (PJI), 7 dislocations (10.2%), and 2 aseptic loosenings (2.9%). Mean VAS at last follow-up was 1.45 compared to 3.2 preoperatively, while mean HHS improved from 21.1 points preoperatively to 61 at last follow-up. The change in both scores was thus significant (p < 0.001). CONCLUSION Defect reconstruction with custom-made modular acetabular implants can be a good, nevertheless expensive, treatment option with clinically and radiologically satisfying results in comparison to recent studies in the literature. Nevertheless, high postoperative complication rates, especially in terms of PJI, remain a challenge.
Collapse
|
18
|
Fraile Suari A, Marqués López F, Cuenca Llavall M, Tey Pons M, León García A. Reconstruction for pelvic discontinuity and massive acetabular defects. Rev Esp Cir Ortop Traumatol (Engl Ed) 2020. [DOI: 10.1016/j.recote.2019.11.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
|
19
|
Wirtz DC, Jaenisch M, Osterhaus TA, Gathen M, Wimmer M, Randau TM, Schildberg FA, Rössler PP. Acetabular defects in revision hip arthroplasty: a therapy-oriented classification. Arch Orthop Trauma Surg 2020; 140:815-825. [PMID: 32100108 PMCID: PMC7244606 DOI: 10.1007/s00402-020-03379-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Indexed: 12/13/2022]
Abstract
INTRODUCTION The treatment of severe acetabular bone loss remains a difficult challenge. No classification system is available that combines intuitive use, structured design and offers a therapeutic recommendation according to the current literature and modern state of the art treatment options. The goal of this study is to introduce an intuitive, reproducible and reliable guideline for the evaluation and treatment of acetabular defects. METHODS The proposed Acetabular Defect Classification (ADC) is based on the integrity of the acetabular rim and supporting structures. It consists of 4 main types of defects ascending in severity and subdivisions narrowing down-defect location. Type 1 presents an intact acetabular rim, type 2 includes a noncontained defect of the acetabular rim ≤ 10 mm, in type 3 the rim defect exceeds 10 mm and type 4 includes different kinds of pelvic discontinuity. A collective of 207 preoperative radiographs were graded according to ADC and correlated with intraoperative findings. Additionally, a randomized sample of 80 patients was graded according to ADC by 5 observers to account for inter- and intra-rater reliability. RESULTS We evaluated the agreement of preoperative, radiographic grading and intraoperative findings presenting with a k value of 0.74. Interobserver agreement presented with a k value of 0.62 and intraobserver at a k value of 0.78. CONCLUSION The ADC offers an intuitive, reliable and reproducible classification system. It guides the surgeon pre- and intraoperatively through a complex field of practice.
Collapse
Affiliation(s)
- Dieter Christian Wirtz
- Department of Orthopaedics and Traumatology, University Hospital Bonn, Germany, Sigmund-Freud-Straße 25, 53127 Bonn, Germany
| | - Max Jaenisch
- Department of Orthopaedics and Traumatology, University Hospital Bonn, Germany, Sigmund-Freud-Straße 25, 53127 Bonn, Germany
| | - Thiemo Antonius Osterhaus
- Department of Orthopaedics and Traumatology, University Hospital Bonn, Germany, Sigmund-Freud-Straße 25, 53127 Bonn, Germany
| | - Martin Gathen
- Department of Orthopaedics and Traumatology, University Hospital Bonn, Germany, Sigmund-Freud-Straße 25, 53127 Bonn, Germany
| | - Matthias Wimmer
- Department of Orthopaedics and Traumatology, University Hospital Bonn, Germany, Sigmund-Freud-Straße 25, 53127 Bonn, Germany
| | - Thomas Martin Randau
- Department of Orthopaedics and Traumatology, University Hospital Bonn, Germany, Sigmund-Freud-Straße 25, 53127 Bonn, Germany
| | - Frank Alexander Schildberg
- Department of Orthopaedics and Traumatology, University Hospital Bonn, Germany, Sigmund-Freud-Straße 25, 53127 Bonn, Germany
| | - Philip Peter Rössler
- Department of Orthopaedics and Traumatology, University Hospital Bonn, Germany, Sigmund-Freud-Straße 25, 53127 Bonn, Germany
| |
Collapse
|
20
|
[Acetabular revision arthroplasty with a novel cementless augment-and-modular-cage system (MRS-C) : Surgical technique and preliminary clinical results]. OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE 2019; 32:248-261. [PMID: 31720726 DOI: 10.1007/s00064-019-00637-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2018] [Revised: 11/02/2018] [Accepted: 11/03/2018] [Indexed: 10/25/2022]
Abstract
OBJECTIVE Optimal reconstruction of acetabular anatomy and primarily stable bridging even of large bone defects in hip revision surgery by intraoperative cementless application of highly modular components of the MRS-TITAN Comfort (MRS-C) system according to the augment-and-modular-cage principle. INDICATIONS Acetabular defect situations in hip revision surgery, hereditary/acquired acetabular deformities, severe secondary hip osteoarthritis. CONTRAINDICATIONS Extended periacetabular defects of the dorsal pillar, pelvic discontinuities, persisting posttraumatic or periprosthetic infections, lack of intraoperative bony anchorage options. SURGICAL TECHNIQUE Conventional positioning. Flexible selection of approach (posterolateral, anterolateral or transgluteal) to the hip joint, if possible using a previous approach. Implant removal, preparation and intraoperative acetabular defect evaluation. Optional impaction bone grafting for biological downsizing. Selection of modular components and augments depending on the defect. Preparation of the obturator foramen for anchorage of the caudal flange. Optional preparation of the os ilium for additional fixation of the cage with flanges. Fixation with polyaxial screws and selection of version/inclination of the cup component. Selection of the inlay (polyethylene/ceramic). POSTOPERATIVE MANAGEMENT Partial weight-bearing with 20 kg body-weight for 6 weeks with crutches. Prophylaxis for deep vein thrombosis and heterotopic ossification. Additional adapted antibiotic therapy in cases of infection. RESULTS A minimum 1‑year follow-up of 42 patients showed significant improvements of Harris Hip Scores (p < 0.0001), adequate reconstruction of the physiologic center of rotation (x-ray controlled in the vertical plane, referenced to the contralateral side), and a clear reduction of preoperative leg length discrepancies. No significant changes in range of motion. No implant-associated complications noted. Based on the short follow-up results, the implant proves as suitable for reconstruction of even large acetabular bone defects.
Collapse
|
21
|
De Martino I, Strigelli V, Cacciola G, Gu A, Bostrom MP, Sculco PK. Survivorship and Clinical Outcomes of Custom Triflange Acetabular Components in Revision Total Hip Arthroplasty: A Systematic Review. J Arthroplasty 2019; 34:2511-2518. [PMID: 31213338 DOI: 10.1016/j.arth.2019.05.032] [Citation(s) in RCA: 57] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 04/30/2019] [Accepted: 05/16/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Several studies have evaluated the survivorship and clinical outcomes of custom triflange acetabular component (CTAC) usage in complex acetabular revision; however, there remains no consensus on the overall performance of this custom implant design. We therefore performed a systematic review of the literature in order to examine survivorship and complication rate of CTAC usage. METHODS A systematic review of the literature according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines was performed. A comprehensive search of PubMed, MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews was conducted for English articles using various combinations of the keywords "custom triflange," "custom-made triflange," "acetabular triflange," "THA," "THR," "revision," "bone loss," "bone defect," and "pelvic discontinuity." RESULTS In all, 17 articles met our inclusion criteria. A total of 579 CTACs were implanted. The all-cause revision-free survivorship was 82.7%. The overall complication rate was 29%. Dislocation and infection were the most common complications observed with an incidence of 11% and 6.2%, respectively. Nerve injuries following CTAC placement had an incidence of 3.8%. The incidence of CTAC aseptic loosening was 1.7%. Overall, patients had improved outcomes as documented by postoperative hip scores. CONCLUSION Based on the current data, CTACs have a high complication rate but remain an efficacious treatment option in complex acetabular reconstructions. When dealing with patients with significant acetabular bone loss for revision total hip arthroplasty, surgeons should continue to consider CTACs as a viable option but educate patients as to the increased risk of postoperative complications and reoperations.
Collapse
Affiliation(s)
- Ivan De Martino
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY
| | - Vanni Strigelli
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY
| | - Giorgio Cacciola
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY
| | - Alex Gu
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY
| | - Mathias P Bostrom
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY
| | - Peter K Sculco
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY
| |
Collapse
|
22
|
Fraile Suari A, Marqués López F, Cuenca Llavall M, Tey Pons M, León García A. Reconstruction for pelvic discontinuity and massive acetabular defects. Rev Esp Cir Ortop Traumatol (Engl Ed) 2019; 64:64-73. [PMID: 31543412 DOI: 10.1016/j.recot.2019.06.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2019] [Revised: 06/01/2019] [Accepted: 06/03/2019] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVE The acetabular reconstruction with massive acetabular defects and pelvic discontinuity is a complex surgery with important difficulties for the orthopaedic surgeon. The objective of this study is to show the short and midterm results of the acetabular revision with the Cup-Cage construct in a consecutive serie of cases. MATERIAL AND METHODS Retrospectively we reviewed 22 consecutive patients with massive acetabular defects (8 Paprosky IIIa and 9 IIIB); 5 pelvic discontinuities; 2 pelvic fractures during the implantation of primary artroplasty, and one pelvic pseudoarthrosis. All were reoperated with a trabecular metal acetabular component and a Cup-Cage. We did clinical and radiological follow-up to detect machanical failures and loosening of the implant. RESULTS With a middle follow-up of 45.06 months (12-73 months) we did not see any radiographic failure of the implant (component migration, osteolysis neither rupture of the implant or screws). The complications (13,63%) included one recurrent luxation, one infection and one recurrent subluxation. The Merle d'Aubigné-Postel score improved from 6.91 to 14.36 and the punctuation in the range of motion from 2.91 to 4.36 on average of the values preoperatively and postoperatively respectively and improvement in Harris Hip Score 30 (16-55) to 72 (40-90) in the latest follow up. CONCLUSION The acetabular reconstruction with the Cup-Cage system is a valid alternative for the reconstruction of massive acetabular defects (Paprosky type IIIA and IIIB) and pelvic discontinuities offering good results at short and midterm follow-up.
Collapse
Affiliation(s)
- A Fraile Suari
- Servicio de Cirugía Ortopédica y Traumatología, Hospital del Mar i l'Esperança, Barcelona, España.
| | - Fernando Marqués López
- Servicio de Cirugía Ortopédica y Traumatología, Hospital del Mar i l'Esperança, Barcelona, España
| | - M Cuenca Llavall
- Servicio de Cirugía Ortopédica y Traumatología, Hospital del Mar i l'Esperança, Barcelona, España
| | - M Tey Pons
- Servicio de Cirugía Ortopédica y Traumatología, Hospital del Mar i l'Esperança, Barcelona, España
| | - A León García
- Servicio de Cirugía Ortopédica y Traumatología, Hospital del Mar i l'Esperança, Barcelona, España
| |
Collapse
|
23
|
Han Q, Zhang K, Zhang Y, Wang C, Yang K, Zou Y, Chen B, Wang J. Individual resection and reconstruction of pelvic tumor with three-dimensional printed customized hemi-pelvic prosthesis: A case report. Medicine (Baltimore) 2019; 98:e16658. [PMID: 31490360 PMCID: PMC6738983 DOI: 10.1097/md.0000000000016658] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
RATIONALE Pelvic tumor had great impact on patients' quality of life. After tumor resection, how to accurately fill bone defect remained challenging for orthopedic surgeons. Due to lack of individual design, high incidence of prosthetic mismatching, and loosening were reported in pelvic reconstruction surgery with conventional modular prostheses. Nowadays, with rapid development of three-dimensional (3D) print technology, pelvic prostheses could be designed according to patients' own anatomy. The objective of this study was to describe the application of 3D printed customized hemi-pelvic prosthesis for patients with pelvic tumor. PATIENT CONCERNS A 62-year-old female had developed severe right joint pain without obvious inducement from 5 months before she sought medical advice. Pain, swelling, and limited range of motion of right joint were founded during physical examination. DIAGNOSIS The patients were diagnosed as "right acetabulum metastatic carcinoma" INTERVENTION:: 3D printed titanium alloy hemi-pelvic prosthesis was designed according the morphology of unaffected side hemi-pelvis and subsequently implanted in surgery to reconstruct the pelvis. 3D printed osteotomy guide and pelvic model were also manufactured and applied to improve accuracy of osteotomy and reduce operation time. X-Ray of pelvis, Harris score, musculoskeletal tumor society score (MSTS) and The MOS item short from health survey (SF-36) were recorded during the period of preoperation, 1, 3, 6, 12 months follow-up after operation. OUTCOMES 3D printed hemi-pelvic prosthesis matched precisely with pelvis and implanted successfully. There was no sign of prosthetic loosening within 12 months' follow-up. No sign of peri-prosthetic infection from laboratory examination. Harris score, MSTS, and SF-36 were gradually increasing during follow-up period. LESSONS Satisfactory effect of pelvic reconstruction could be achieved by 3D printed hemi-pelvic prostheses. It also provided a promising way to the treatment of pelvic tumor in similar cases.
Collapse
Affiliation(s)
| | | | - Yong Zhang
- Clinical Laboratories, Second Hospital of Jilin University, Changchun, Jilin Province, China
| | | | | | | | | | | |
Collapse
|
24
|
Castelli E, Schmierer PA, Pozzi A. Custom acetabular prosthesis for total hip replacement: A case report in a dog with acetabular bone loss after femoral head and neck ostectomy. Vet Surg 2019; 48:1520-1529. [PMID: 31441512 DOI: 10.1111/vsu.13303] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Revised: 06/30/2019] [Accepted: 07/16/2019] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To describe the application of a custom acetabular prosthesis (CAP) for total hip replacement (THR) in a dog 20 months after femoral head and neck ostectomy (FHNO). STUDY DESIGN Case report. ANIMAL A 10-year-old, male, castrated, Labrador retriever with progressive lameness and pain after FHNO. METHODS Acetabular bone stock was assessed as insufficient for conventional THR, so a biflanged CAP was designed and three-dimensionally printed in titanium to bridge the bone defect. The CAP had a porous surface for long-term biologic fixation on the backside and was anchored to the ilium and ischium with screws. A polyethylene cup was cemented into the CAP, and a bolted cementless femoral stem was inserted. RESULTS The loss of the conventional anatomic landmarks complicated intraoperative orientation and led to eccentric reaming and 5-mm malalignment of the CAP. Reduction of the prosthetic joint was difficult because of periarticular fibrosis, loss of functional muscle length, and thickness of the CAP, and intraoperative shortening of the stem neck was required. Postoperative complications included sciatic neurapraxia, which resolved with time and conservative management. Absence of pain and improvement of range of motion were observed at clinical examination 12 months after surgery; however, moderate hind limb lameness persisted due to muscle tension. No evidence of implant loosening was noted on radiographs acquired 24 months after surgery. CONCLUSION Femoral head and neck ostectomy with poor functional outcome was ameliorated by using a CAP in this dog. CLINICAL SIGNIFICANCE Use of a CAP can be considered to treat acetabular defects in dogs.
Collapse
Affiliation(s)
- Emanuele Castelli
- Clinic for Small Animal Surgery, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
| | - Philipp A Schmierer
- Clinic for Small Animal Surgery, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
| | - Antonio Pozzi
- Clinic for Small Animal Surgery, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
| |
Collapse
|
25
|
Ahmed GA, Ishaque B, Rickert M, Fölsch C. [Allogeneic bone transplantation in hip revision surgery : Indications and potential for reconstruction]. DER ORTHOPADE 2019; 47:52-66. [PMID: 29260246 DOI: 10.1007/s00132-017-3506-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The increasing number of people having joint replacements will lead to increasing numbers of revision operations. The transplantation of allogeneic bones might reconstruct bone defects and improve long-term anchorage of the implant. A sufficient primary stability of the implanted construct is necessary to achieve osseous incorporation as well as tight contact between the implanted allogeneic and host bones. Transplantation of bone can contribute to downgrading acetabular defects and so avoid bigger reinforcement implants. An improvement of bone stock due to reconstruction of femoral bony defects might also reduce the size of the stem necessary since the indication might be limited in case of extensive bone defects. According to good longterm results of modular revision stems the Impaction-Bone-Grafting has not yet generally been established.
Collapse
Affiliation(s)
- G A Ahmed
- Klinik und Poliklinik für Orthopädie und Orthopädische Chirurgie, Justus-Liebig-Universität Gießen, Klinikstraße 33, 35392, Gießen, Deutschland.
| | - B Ishaque
- Klinik und Poliklinik für Orthopädie und Orthopädische Chirurgie, Justus-Liebig-Universität Gießen, Klinikstraße 33, 35392, Gießen, Deutschland
| | - M Rickert
- Klinik und Poliklinik für Orthopädie und Orthopädische Chirurgie, Justus-Liebig-Universität Gießen, Klinikstraße 33, 35392, Gießen, Deutschland
| | - C Fölsch
- Klinik und Poliklinik für Orthopädie und Orthopädische Chirurgie, Justus-Liebig-Universität Gießen, Klinikstraße 33, 35392, Gießen, Deutschland
| |
Collapse
|
26
|
The augment-and-modular-cage revision system for reconstruction of severe acetabular defects-two-year clinical and radiographic results. INTERNATIONAL ORTHOPAEDICS 2018; 43:2269-2278. [PMID: 30539219 DOI: 10.1007/s00264-018-4271-6] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2018] [Accepted: 12/03/2018] [Indexed: 12/11/2022]
Abstract
PURPOSE Acetabular revision of failed total hip arthroplasty (THA) is often associated with severe bone loss. Therefore, a variety of revision implant systems has been developed during recent years, with the augment-and-modular-cage system being one of the newest additions to this portfolio. Together with biologic downsizing by means of impaction bone grafting, this uncemented system promises a high modularity and versatility to treat all acetabular defects up to Paprosky types IIIa and IIIb without pelvic discontinuity. The aim of the present study was to evaluate first short-term results of its clinical application, both clinical functional and patient-reported as well as radiographic. METHODS Forty-four patients (28 female, 16 male, mean age 70.9 ± 11.5 years) could be followed for a mean of 26 ± 10 months after acetabular revision with a novel augment-and-modular-cage system. Indications for revision included aseptic loosening (68%), septic loosening (16%), or others (16%) with bone loss Paprosky IIa up to IIIb without discontinuity. The modified Harris Hip Score (mHHS) served as a primary outcome parameter. In addition, a number of patient-reported outcome measurements (PROMs) were collected including the Short Form 36 (SF-36), Hip disability and Osteoarthritis Outcome Score (HOOS), and Visual Analogue Scale for Hip Pain (VAS Hip) as well as overall satisfaction. Radiographic changes between the pre- and postoperative center of rotation (COR) and various criteria of implant failure served as secondary outcome parameters. RESULTS No patients were lost to follow-up. Two implant-associated complications (partial flange breakage) without a need for revision surgery were detected, which represent a failure rate of 4.5%. Functional outcome as measured by mHHS increased from 49.4 ± 2.9 pre-operatively to 74.4 ± 3.1 at the latest follow-up (p < 0.001). PROMs showed significant improvements in all pain-related categories, while other quality-of-life measurements only exhibited positive tendencies towards improvement. VAS Hip significantly improved from 6.5 ± 0.7 pre-operatively to 2.2 ± 0.6 at the latest follow-up (p < 0.001). Radiographic evaluation showed that reconstruction of the COR was possible, referenced to the contralateral side. The COR could be lateralized by 5.0 mm (n.s.) and caudalized by 10.3 mm (p < 0.001) comparing pre-operative and post-operative states, with complete osseointegration in 95% of the cases. CONCLUSIONS Treatment with the augment-and-modular-cage system significantly improved clinical functional and patient-reported outcomes in cases of acetabular revision after failed THA. In addition, a good reconstruction of the COR could also be achieved. Therefore, this highly modular system can be considered as an effective treatment option in almost all cases of acetabular bone loss except for those of pelvic discontinuity. It offers the unique possibility of intra-operative implant customization according to the existing bone defect and host bone quality.
Collapse
|
27
|
Three-dimension-printed custom-made prosthetic reconstructions: from revision surgery to oncologic reconstructions. INTERNATIONAL ORTHOPAEDICS 2018; 43:123-132. [DOI: 10.1007/s00264-018-4232-0] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Accepted: 11/06/2018] [Indexed: 10/27/2022]
|
28
|
Sheth NP, Melnic CM, Brown N, Sporer SM, Paprosky WG. Two-centre radiological survivorship of acetabular distraction technique for treatment of chronic pelvic discontinuity: mean five-year follow-up. Bone Joint J 2018; 100-B:909-914. [PMID: 29954194 DOI: 10.1302/0301-620x.100b7.bjj-2017-1551.r1] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Aims The aim of this study was to examine the results of the acetabular distraction technique in achieving implantation of a stable construct, obtaining biological fixation, and producing healing of chronic pelvic discontinuity at revision total hip arthroplasty. Patients and Methods We identified 32 patients treated between 2006 and 2013 who underwent acetabular revision for a chronic pelvic discontinuity using acetabular distraction, and who were radiographically evaluated at a mean of 62 months (25 to 160). Of these patients, 28 (87.5%) were female. The mean age at the time of revision was 67 years (44 to 86). The patients represented a continuous series drawn from two institutions that adhered to an identical operative technique. Results Of the 32 patients, one patient required a revision for aseptic loosening, two patients had evidence of radiographic loosening but were not revised, and three patients had migration of the acetabular component into a more stable configuration. Radiographically, 22 (69%) of the cohort demonstrated healing of the discontinuity. The Kaplan-Meier construct survivorship was 83.3% when using revision for aseptic acetabular loosening as an endpoint. At the time when one patient failed due to aseptic loosening (at 7.4 years), there were a total of seven patients with a follow-up of seven years or longer who were at risk of failure. Conclusion The acetabular distraction technique demonstrates encouraging radiographic outcomes, with healing of the discontinuity in over two-thirds of our series. This surgical technique permits biological fixation and intraoperative customization of the construct to be implanted based on the pattern of the bone loss identified following component removal. Cite this article: Bone Joint J 2018;100-B:909-14.
Collapse
Affiliation(s)
- N P Sheth
- Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - C M Melnic
- Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - N Brown
- Loyola University Medical Center, Maywood, Illinois, USA
| | - S M Sporer
- Rush University, Chicago, Illinois, USA and Central DuPage Hospital, Northwestern University, Evanston, Illinois, USA
| | - W G Paprosky
- Rush University, Chicago, Illinois, USA and Central DuPage Hospital, Northwestern University, Evanston, Illinois, USA
| |
Collapse
|
29
|
Abstract
INTRODUCTION The treatment of extensive bone loss and massive acetabular defects can be compounded by several challenges and pitfalls. The survivorship following acetabular revision with extensive bone loss is still unsatisfactory. The goal of the present study was to analyse the outcomes of 3D-printed patient-specific acetabular components in the management of extensive acetabular defects and combined pelvic discontinuity (PD). METHODS 9 patients underwent revision THA using 3D-printed custom acetabular components to reconstruct extensive acetabular defects. The Paprosky classifications were determined in all patients. The primary outcome measure was the implant-associated failure rate. RESULTS 1 out of 9 patients suffered an implant-associated complication (11%). The overall implant-associated survival rate was 89%. The overall complication rate was 56%. CONCLUSIONS The patient-specific acetabular component technique shows promise for the treatment of patients with severe acetabular defects in revision THA. Further research aimed at reducing costs and improving the complication rate are warranted.
Collapse
|
30
|
Ribes-Iborra J, Atienza C, Sevil-De la Torre J, Gómez Pérez A. Biomechanical study of pelvic discontinuity in failed total hip arthroplasty. Lessons learnt from the treatment of pelvic fractures. Injury 2017; 48 Suppl 6:S34-S39. [PMID: 29162239 DOI: 10.1016/s0020-1383(17)30792-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Pelvic discontinuity is a rare but serious problem in orthopedic surgery. Acetabular reconstruction in case of severe bone loss after failed total hip arthroplasty is technically difficult, especially in segmental loss type III (anterior or posterior) or pelvic discontinuity (type IV). Acetabular reinforcement devices are frequently used as load-sharing devices to allow allograft incorporation and in order to serve as support of acetabular implants. This study tries to show, by means of biomechanic work, the efficiency of reinforced plate in anterior column in a segmental pelvic loss, illustrated with a clinical case, which shows the socket stability of hip prosthesis.
Collapse
Affiliation(s)
- Julio Ribes-Iborra
- Department of Orthopaedic Surgery, Hospital Universitario de la Ribera, Alzira, Valencia, Spain.
| | - Carlos Atienza
- Instituto de Biomecánica de Valencia-CIBER BBN, Grupo de Tecnología Sanitaria (GTS-IBV), Valencia, Spain
| | - Jorge Sevil-De la Torre
- Department of Orthopaedic Surgery, Hospital Universitario de la Ribera, Alzira, Valencia, Spain
| | - Amelia Gómez Pérez
- Department of Mechanical Engineering. Instituto de Biomecánica de Valencia (IBV), Universidad Politécnica, Valencia, Spain
| |
Collapse
|
31
|
Koob S, Scheidt S, Randau TM, Gathen M, Wimmer MD, Wirtz DC, Gravius S. [Biological downsizing : Acetabular defect reconstruction in revision total hip arthroplasty]. DER ORTHOPADE 2017; 46:158-167. [PMID: 28074234 DOI: 10.1007/s00132-016-3379-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
BACKGROUND Periacetabular bony defects remain a great challenge in revision total hip arthroplasty. After assessment and classification of the defect and selection of a suitable implant the primary stable fixation and sufficient biological reconstitution of a sustainable bone stock are essential for long term success in acetabular revision surgery. Biological defect reconstruction aims for the down-sizing of periacetabular defects for later revision surgeries. TECHNIQUE In the field of biological augmentation several methods are currently available. Autologous transplants feature a profound osseointegrative capacity. However, limitations such as volume restrictions and secondary complications at the donor site have to be considered. Structural allografts show little weight bearing potential in the long term and high failure rates. In clinical practice, the usage of spongious chips implanted via impaction bone grafting technique in combination with antiprotrusio cages for the management of contained defects have shown promising long time results. Nevertheless, when dealing with craniolateral acetabular and dorsal column defects, the additional implantation of macroporous metal implants or augments should be considered since biological augmentation has shown little clinical success in these particular cases. PROSPECT This article provides an overview of the current clinically available biological augmentation methods of peri-acetabular defects. Due to the limitations of autologous and allogeneic bone transplants in terms of size and availability, the emerging field of innovative implantable tissue engineering constructs gains interest and will also be discussed in this article.
Collapse
Affiliation(s)
- S Koob
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Rheinische Friedrich-Wilhelms-Universität Bonn, Sigmund-Freud-Str. 25, 53127, Bonn, Deutschland
| | - S Scheidt
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Rheinische Friedrich-Wilhelms-Universität Bonn, Sigmund-Freud-Str. 25, 53127, Bonn, Deutschland
| | - T M Randau
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Rheinische Friedrich-Wilhelms-Universität Bonn, Sigmund-Freud-Str. 25, 53127, Bonn, Deutschland
| | - M Gathen
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Rheinische Friedrich-Wilhelms-Universität Bonn, Sigmund-Freud-Str. 25, 53127, Bonn, Deutschland
| | - M D Wimmer
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Rheinische Friedrich-Wilhelms-Universität Bonn, Sigmund-Freud-Str. 25, 53127, Bonn, Deutschland
| | - D C Wirtz
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Rheinische Friedrich-Wilhelms-Universität Bonn, Sigmund-Freud-Str. 25, 53127, Bonn, Deutschland
| | - S Gravius
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Rheinische Friedrich-Wilhelms-Universität Bonn, Sigmund-Freud-Str. 25, 53127, Bonn, Deutschland.
| |
Collapse
|
32
|
Hayashi S, Nishiyama T, Hashimoto S, Matsumoto T, Takayama K, Ishida K, Nishida K, Kuroda R. Risk factors for failure of revision total hip arthroplasty using a Kerboull-type acetabular reinforcement device. BMC Musculoskelet Disord 2017; 18:382. [PMID: 28865420 PMCID: PMC5581424 DOI: 10.1186/s12891-017-1741-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/30/2017] [Accepted: 08/28/2017] [Indexed: 11/27/2022] Open
Abstract
Background The present study aimed to identify the risk factors associated with revision total hip arthroplasty (THA) failure using a Kerboull-type (KT) plate. Methods We analyzed 77 revision THAs using cemented acetabular components with a KT plate for aseptic loosening between May 2000 and March 2012. We examined the association of bone graft type, acetabular bone defects, age at the time of surgery, preoperative Japanese Orthopaedic Association (JOA) score, postoperative JOA hip score, and body mass index, with radiographic failure as the outcome. Results The 7.4-year radiographic failure survival rate was 81.6%. The survival rate was significantly different between the beta-tricalcium phosphate (β-TCP) group and the bulk allograft group (p = 0.019). The survival curves were also significantly different between the β-TCP group and bulk allograft group (p = 0.036). American Academy of Orthopaedic Surgeons type IV was significantly associated with radiographic failure (odds ratio [OR]: 15.5, 95% confidence interval [CI]: 1.4–175.4; p = 0.032). Conclusions The midterm outcomes of revision THA indicate that type of bone graft and bone defect size may affect radiographic survival rate when using a KT plate.
Collapse
Affiliation(s)
- Shinya Hayashi
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.
| | - Takayuki Nishiyama
- Department of Orthopaedic Surgery, Kakogawa City Hospital, Kakogawa, Japan
| | - Shingo Hashimoto
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan
| | - Tomoyuki Matsumoto
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan
| | - Koji Takayama
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan
| | - Kazunari Ishida
- Department of Orthopaedic Surgery, Kobe Kaisei Hospital, Kobe, Japan
| | - Kotaro Nishida
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan
| | - Ryosuke Kuroda
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan
| |
Collapse
|
33
|
Reconstruction of AAOS type III and IV acetabular defects with the Ganz reinforcement ring: high failure in pelvic discontinuity. Arch Orthop Trauma Surg 2017. [PMID: 28623470 DOI: 10.1007/s00402-017-2731-x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
BACKGROUND Large acetabular defects and pelvic discontinuity represent complex problems in revision total hip arthroplasty. This study aimed to investigate whether reconstruction with the Ganz reinforcement ring would provide durable function in large acetabular defects. PATIENTS AND METHODS 46 hips (45 patients, 19 male, 26 female, mean age 68 years) with AAOS type III and IV defects undergoing acetabular revision with the Ganz reinforcement ring were evaluated at a mean follow-up of 74 months (24-161 months). Fourteen patients died during follow-up. All surviving patients were available for clinical assessment and radiographic studies. Radiographs were evaluated for bone healing and component loosening. A Cox-regression model was performed to identify factors influencing survival of the Ganz-ring. RESULTS In the group of AAOS III defects, 3 of 26 acetabular reconstructions failed, all due to aseptic loosening. In pelvic discontinuity (AAOS IV), 9 of 20 hips failed due to aseptic loosening (n = 4), deep infection (n = 3), and non-union of the pelvic ring (n = 2). With acetabular revision for any reason as an endpoint, the estimated Kaplan-Meier 5-year survival was 86% in type III defects and 57% in type IV defects, respectively. The presence of pelvic discontinuity was identified as the only independent predictive factor for failure of the Ganz ring acetabular reconstruction (AAOS III vs. IV, Hazard ratio: 0.217, 95%, Confidence interval: 0.054-0.880, p = 0.032). CONCLUSION The Ganz reinforcement ring remains a favorable implant for combined segmental and cavitary defects. However, defects with pelvic discontinuity demonstrate high failure rates. The indications should therefore be narrowed to acetabular defects not associated with pelvic discontinuity.
Collapse
|
34
|
Stihsen C, Hipfl C, Kubista B, Funovics PT, Dominkus M, Giurea A, Windhager R. Review of the outcomes of complex acetabular reconstructions using a stemmed acetabular pedestal component. Bone Joint J 2016; 98-B:772-9. [DOI: 10.1302/0301-620x.98b6.36469] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2015] [Accepted: 02/08/2016] [Indexed: 11/05/2022]
Abstract
Aim Until now, there has been no consensus as to whether stemmed acetabular components are appropriate for use in patients undergoing revision total hip arthroplasty (THA) who have major acetabular defects or pelvic discontinuity. We wished to address this deficiency in the literature. Patients and Methods We carried out a retrospective study of 35 patients (six men and 29 women) with a mean age of 68 years (37 to 87), with major acetabular defects who underwent revision THA between 2000 and 2012. Results At a mean follow-up of 63 months (24 to 141), a total of 15 patients (43%) had required at least one further operation. Six implants (17%) loosened aseptically, four (11%) were further revised for infection and two (6%) for technical failure. By taking revision for any reason as the endpoint, the rate of survival of the implant was 61% after five years; by taking revision for aseptic loosening as the end point, it was 78%. The cumulative five-year survival for aseptic loosening was 94% in patients without pelvic discontinuity, and 56% in those with pelvic discontinuity. Conclusion These results indicate a significantly worse survival in patients with pelvic discontinuity (p = 0.020) and we advise caution in the use of the pedestal component in patients with major acetabular defects and pelvic discontinuity who require revision THA. As a result of these findings we have stopped using this implant and prefer to use particulate bone grafts protected with an anti-protrusion cage and posterior column plate fixation, if necessary. Take home message: Based on these poor results, we advise caution if using the pedestal component in patients with major acetabular defects with the presence of a pelvic discontinuity. Cite this article: Bone Joint J 2016;98-B:772–9.
Collapse
Affiliation(s)
- C. Stihsen
- Vienna General Hospital Medical University
of Vienna, Waehringer Gürtel 18-20, 1190 Wien, Austria
| | - C. Hipfl
- Vienna General Hospital Medical University
of Vienna, Waehringer Gürtel 18-20, 1190 Wien, Austria
| | - B. Kubista
- Vienna General Hospital Medical University
of Vienna, Waehringer Gürtel 18-20, 1190 Wien, Austria
| | - P. T. Funovics
- Vienna General Hospital Medical University
of Vienna, Waehringer Gürtel 18-20, 1190 Wien, Austria
| | - M. Dominkus
- Vienna General Hospital Medical University
of Vienna, Waehringer Gürtel 18-20, 1190 Wien, Austria
| | - A. Giurea
- Vienna General Hospital Medical University
of Vienna, Waehringer Gürtel 18-20, 1190 Wien, Austria
| | - R. Windhager
- Vienna General Hospital Medical University
of Vienna, Waehringer Gürtel 18-20, 1190 Wien, Austria
| |
Collapse
|
35
|
te Stroet MAJ, Rijnen WHC, Gardeniers JWM, van Kampen A, Schreurs BW. Satisfying outcomes scores and survivorship achieved with impaction grafting for revision THA in young patients. Clin Orthop Relat Res 2015; 473:3867-75. [PMID: 25894808 PMCID: PMC4626523 DOI: 10.1007/s11999-015-4293-y] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND The increasing number of total hip arthroplasties (THAs) performed in younger patients will inevitably generate larger numbers of revision procedures for this specific group of patients. Unfortunately, no satisfying revision method with acceptable survivorship 10 years after revision has been described for these patients so far. QUESTIONS/PURPOSES The purposes of this study were to (1) analyze the clinical outcome; (2) complication rate; (3) survivorship; and (4) radiographic outcome of cemented revision THA performed with impaction bone grafting (IBG) on both the acetabular and femoral sides in one surgery in patients younger than 55 years old. METHODS During the period 1991 to 2007, 86 complete THA revisions were performed at our institution in patients younger than 55 years. In 34 of these 86 revisions (40%), IBG was used on both the acetabular and femoral sides in 33 patients. Mean patient age at revision surgery was 46.4 years (SD 7.6). No patient was lost to followup, but three patients died during followup. None of the deaths were related to the revision surgery. The mean followup for the surviving hips was 11.7 years (SD 4.6). We also analyzed complication rate. RESULTS The mean Harris hip score improved from 55 (SD 18) preoperatively to 80 points (SD 16) at latest followup (p = 0.009). Six hips underwent a rerevision (18%): in four patients, both components were rerevised; and in two hips, only the cup was revised. Patient 10-year survival rate with the endpoint of rerevision for any component for any reason was 87% (95% confidence interval [CI], 67%-95%) and with the endpoint of rerevision for aseptic loosening, the survival rate was 97% (95% CI, 80%-100%). In total six cups were considered radiographically loose, of which four were rerevised. Three stems were radiographically loose, of which none was rerevised. CONCLUSIONS IBG is a valuable biological revision technique that may restore bone stock in younger patients. Bone stock reconstruction is important, because these patients likely will outlive their revision implants. Bone reconstruction with impaction grafting may facilitate future revisions. LEVEL OF EVIDENCE Level IV, therapeutic study.
Collapse
Affiliation(s)
| | - Wim H. C. Rijnen
- Radboud University Medical Center, Geert Grooteplein 10, 6525 GA Nijmegen, The Netherlands
| | - Jean W. M. Gardeniers
- Radboud University Medical Center, Geert Grooteplein 10, 6525 GA Nijmegen, The Netherlands
| | - Albert van Kampen
- Radboud University Medical Center, Geert Grooteplein 10, 6525 GA Nijmegen, The Netherlands
| | - B. Willem Schreurs
- Radboud University Medical Center, Geert Grooteplein 10, 6525 GA Nijmegen, The Netherlands
| |
Collapse
|
36
|
Zazgyva A, Zuh SG, Roman CO, Gergely I, Pop TS. Acetabular reconstruction with a reinforcement device and bone grafting in revision arthroplasty-a mean five years of follow-up. INTERNATIONAL ORTHOPAEDICS 2015; 40:1631-1638. [PMID: 26546063 DOI: 10.1007/s00264-015-3030-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2015] [Accepted: 10/21/2015] [Indexed: 12/12/2022]
Abstract
PURPOSE To evaluate the clinical and radiological outcomes of acetabular reconstruction using a reinforcement device (RD) in combination with bone grafting in Paprosky type 2 and 3 acetabular bone defects. METHODS Morselised bone grafts were used to fill cavitary defects and a structural graft placed in the superior part of the acetabulum in cases of cranial bone defects, with a proximally fixed RD (Protetim, Hódmezővásárhely, Hungary) implanted in all cases. Construct stability, device positioning, hip centre of rotation and medial acetabular wall thickness were evaluated radiologically. Survival rates were estimated with aseptic loosening and revision for any reason as endpoints. RESULTS The 28 patients (29 hips) were followed for 4.8 ± 2.7 years (range, 2-10.4 years). Hip centre of rotation was lowered in all cases, with no significant differences between the mean values obtained post-operatively and at the last follow-up. Medial acetabular wall thickness and RD abduction angle were maintained up to the last evaluation. Bone grafts integrated by two years post-operatively in the majority of cases. Kaplan-Meier survival rates were 85.2 % and 82.1 % for the two endpoints at ten years. CONCLUSIONS Acetabular reconstruction using a proximally fixed RD in combination with bone grafting offered good mid-term results in the treatment of acetabular bone defects. In cases of severe bone loss, the structural allograft allowed placement of the RD with ischial contact, rendering survival rates similar to RDs with both iliac and ilioischial fixation. The technique was successful in restoring and maintaining medial acetabular bone stock and construct stability for up to ten years.
Collapse
Affiliation(s)
- Ancuța Zazgyva
- Clinic of Orthopaedics and Traumatology, Mureș County Hospital, 31 Mihai Viteazul Street, Tîrgu Mureș, 540096, Romania
| | - Sándor-György Zuh
- Department of Orthopaedics and Traumatology I, University of Medicine and Pharmacy Tîrgu Mureș, 31 Mihai Viteazul Street, Tîrgu Mureș, 540096, Romania.
| | - Ciprian Oliviu Roman
- Department of Orthopaedics and Traumatology I, University of Medicine and Pharmacy Tîrgu Mureș, 31 Mihai Viteazul Street, Tîrgu Mureș, 540096, Romania
| | - István Gergely
- Department of Orthopaedics and Traumatology I, University of Medicine and Pharmacy Tîrgu Mureș, 31 Mihai Viteazul Street, Tîrgu Mureș, 540096, Romania
| | - Tudor Sorin Pop
- Department of Orthopaedics and Traumatology I, University of Medicine and Pharmacy Tîrgu Mureș, 31 Mihai Viteazul Street, Tîrgu Mureș, 540096, Romania
| |
Collapse
|
37
|
Mao Y, Xu C, Xu J, Li H, Liu F, Yu D, Zhu Z. The use of customized cages in revision total hip arthroplasty for Paprosky type III acetabular bone defects. INTERNATIONAL ORTHOPAEDICS 2015; 39:2023-30. [PMID: 26285669 DOI: 10.1007/s00264-015-2965-6] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2015] [Accepted: 07/29/2015] [Indexed: 02/02/2023]
Abstract
PURPOSE Revision total hip arthroplasty (THA) is challenging if severe periacetabular bone loss is present. Here we describe a method that uses a customised cage to reconstruct an acetabulum with a massive bone defect. METHODS Designed with the aid of the rapid prototyping technique, a customised cage with a hook, crest and flange or braids was made, and then utilized to reconstruct severe compromised acetabulum in revision THA since 2001. Twenty-two patients (23 hips) were included in this study. The mean patient age at the time of surgery was 60.9 years (range, 38-80 years). Three hips had massive acetabular bone defects of Paprosky type IIIA and 20 of type IIIB. The Harris hip score was used to evaluate hip function. Radiographs were taken to evaluate loosening of the cage and resorption of allograft bone. RESULTS The average follow up was 81.6 ± 24.9 months. The mean Harris hip score improved from 39.6 pre-operatively to 80.9 at the final follow-up. There were no instances of deep infection, severe venous thrombosis, and nerve palsy. One patient who had an intra-operative rupture of the superior acetabular artery was successfully treated using the haemostatic suturing technique. Two patients experienced dislocation at post-operative days four and six, respectively, and both were treated with closed reduction and skin traction for three weeks. CONCLUSIONS The present study demonstrates that a customised cage may be a promising option for THA revision of severely compromised acetabula. Extended follow-up is necessary to evaluate the long-term performance of this approach.
Collapse
Affiliation(s)
- Yuanqing Mao
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai, 200011, People's Republic of China
| | - Chen Xu
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai, 200011, People's Republic of China
| | - Jiawei Xu
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai, 200011, People's Republic of China
| | - Huiwu Li
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai, 200011, People's Republic of China
| | - Fengxiang Liu
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai, 200011, People's Republic of China
| | - Degang Yu
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai, 200011, People's Republic of China.
| | - Zhenan Zhu
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai, 200011, People's Republic of China.
| |
Collapse
|
38
|
Validation of the Charlson comorbidity index in patients undergoing revision total hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2015; 39:1771-7. [DOI: 10.1007/s00264-015-2810-y] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2015] [Accepted: 06/05/2015] [Indexed: 01/15/2023]
|