1
|
Cheng R, Blevins J, Debbi EM, Chiu YF, Gonzalez Della Valle A, Lee GC. Contemporary Isolated Bearing Exchange for the Management of Hip Instability Following Primary Total Hip Arthroplasty. J Arthroplasty 2024; 39:S173-S177. [PMID: 38522800 DOI: 10.1016/j.arth.2024.03.039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 03/12/2024] [Accepted: 03/15/2024] [Indexed: 03/26/2024] Open
Abstract
BACKGROUND Isolated ball and liner exchanges (IBLEs) can be performed to increase hip joint stability, but historical results have been mixed due to a lack of head size options or dual mobility articulations. The purpose of this study was to evaluate the contemporary results of IBLEs in patients who have instability following primary total hip arthroplasty (THA). METHODS We retrospectively reviewed 65 primary THAs from 2016 to 2020 with hip instability undergoing IBLE or conversion to dual mobility articulation. There were 31 men and 34 women who had an average age of 70 years (range, 26 to 92). The mean time to revision from primary was 40.1 months (range, 1 to 120). In 52 cases, IBLE was performed using conventional bearings, while 13 hips were converted to dual mobility. Radiographic factors, including acetabular component orientation, reproduction of hip joint offset, leg lengths, and outcomes such as recurrent instability requiring subsequent revision and patient-reported outcome measure, were recorded and compared. RESULTS There were 12 (18.4%) hips that experienced subsequent instability and required another revision (17.3% ball and liner exchange versus 23.1% dual mobility articulation, P = .615). The mean time to rerevision for instability was 17.1 months. There were no significant differences in either acetabular component anteversion (P = .25) or restoration of hip joint offset (P = .87) in patients who required another revision for instability compared to those who did not, respectively. At 1 year, patients undergoing conventional bearing exchange reported higher Hip Dysfunction Osteoarthritis Outcome Score for Joint Replacements (P = .002) and Veterans Rand physical component (P = .023) scores compared to those who underwent a conversion to dual mobility articulation. Only age > 75 years at the time of surgery was associated with increased risk for dislocation (odds ratio 7.2, confidence interval 1.2 to 43.7, P = .032). CONCLUSIONS Isolated bearing exchanges for instability following THA remained at high risk for subsequent instability. Conversion to dual mobility articulations did not reduce the risk of reoperation.
Collapse
Affiliation(s)
- Ryan Cheng
- Division of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York
| | - Jason Blevins
- Division of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York
| | - Eytan M Debbi
- Division of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York
| | - Yu-Fen Chiu
- Division of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York
| | | | - Gwo-Chin Lee
- Division of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York
| |
Collapse
|
2
|
Xiao Q, Ling T, Zhou K, Yuan M, Xu B, Zhou Z. Constrained acetabular liners are a viable option in second-stage re-implantation for chronic infected total hip arthroplasty with abductor or greater trochanter deficiency and large acetabular bone defects. BMC Musculoskelet Disord 2022; 23:915. [PMID: 36242038 PMCID: PMC9563789 DOI: 10.1186/s12891-022-05861-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Accepted: 09/27/2022] [Indexed: 11/10/2022] Open
Abstract
Background Abductor mechanism deficiency is a clear indication for using constrained acetabular liners (CALs), and large acetabular bone defects are considered a relative contraindication to CALs. We report the results of using CALs in special cases in which abductor or greater trochanter deficiency was accompanied by large acetabular bone defects at second-stage re-implantation for chronic infected total hip arthroplasty (THA). Methods Between January 2010 and January 2018, 19 patients who used CALs at second-stage re-implantation and had abductor or greater trochanter deficiency and large acetabular bone defects were included in this study. We followed up with the clinical and radiological results of these patients. Complications and infection-related information were also recorded. Results Eight patients, 4 patients, and 7 patients had Paprosky type IIB, type IIC, and type IIIA acetabular bone defects at second-stage re-implantation, respectively. The indication for using CALs was abductor deficiency in 14 patients and greater trochanter deficiency in the other 5 patients. The mean follow-up was 74.4 months (range 50–96). The mean Harris Hip Score (HHS) was 76.3 points (range 62–86) at the last follow-up. Three patients presented acetabular radiolucent lines with no progress: zone 3, zone 3 and zone 2 and 3, respectively. One patient suffered transient sciatic nerve palsy. There was no dislocation, failure of the CALs, reoperation, or recurrence of infection. Conclusion Our results suggested that for screened patients, CALs are a viable option in second-stage re-implantation for chronic infected THA with abductor or greater trochanter deficiency and large bone defects.
Collapse
Affiliation(s)
- Qiang Xiao
- Department of Orthopedics, West China School of Medicine, West China Hospital, Sichuan University, 37# Wuhou Guoxue Road, 610041, Chengdu, People's Republic of China.,Department of Orthopedics, Chengdu Second People's Hospital, Chengdu, People's Republic of China
| | - Tingxian Ling
- Department of Orthopedics, West China School of Medicine, West China Hospital, Sichuan University, 37# Wuhou Guoxue Road, 610041, Chengdu, People's Republic of China
| | - Kai Zhou
- Department of Orthopedics, West China School of Medicine, West China Hospital, Sichuan University, 37# Wuhou Guoxue Road, 610041, Chengdu, People's Republic of China
| | - Mingcheng Yuan
- Department of Orthopedics, West China School of Medicine, West China Hospital, Sichuan University, 37# Wuhou Guoxue Road, 610041, Chengdu, People's Republic of China
| | - Bing Xu
- Department of Orthopedics, Chengdu Second People's Hospital, Chengdu, People's Republic of China
| | - Zongke Zhou
- Department of Orthopedics, West China School of Medicine, West China Hospital, Sichuan University, 37# Wuhou Guoxue Road, 610041, Chengdu, People's Republic of China.
| |
Collapse
|
3
|
Ogonda L, Cassidy RS, Beverland DE. A conservative approach to dislocation following total hip arthroplasty: a review of 8606 hips. Hip Int 2022; 32:291-297. [PMID: 32905705 DOI: 10.1177/1120700020959062] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
PATIENTS AND METHODS We present the data on 8606 total hip arthroplasty (THA) procedures carried out in 7818 patients through a posterior approach between 1998 and 2017. RESULTS 218 hips (2.5%) suffered at least 1 dislocation with dislocation rates declining from 6.2% from 1998 to 2002 to 1.5% from 2003 to 2017. Overall, 92 hips (1.06%) required revision surgery but of these, only 5 (0.06%) had a full revision of both components with the remaining 87 requiring intervention only on the acetabular side. None have had a pseudo-arthrosis; none were left dislocated and all remain stable to date. CONCLUSIONS In patients who have a second dislocation within 3 months of their primary surgery we recommend a spica or long leg cylinder cast to reduce the need for revision surgery. We propose an algorithm to manage instability with less aggressive operative treatment in this often-elderly patient population with the potential for less physiological insult and significant cost savings.
Collapse
Affiliation(s)
- Luke Ogonda
- Outcomes Unit, Primary Joint Unit, Musgrave Park Hospital, Belfast, UK
| | - Roslyn S Cassidy
- Outcomes Unit, Primary Joint Unit, Musgrave Park Hospital, Belfast, UK
| | - David E Beverland
- Outcomes Unit, Primary Joint Unit, Musgrave Park Hospital, Belfast, UK
| |
Collapse
|
4
|
Arbeloa-Gutierrez L, Arenas-Miquelez A. Atraumatic Anterior Hip Dislocation as High Grade of Hip Instability: A Case Report. JBJS Case Connect 2021; 11:01709767-202106000-00024. [PMID: 33979811 DOI: 10.2106/jbjs.cc.20.00542] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
CASE Fifty-year-old woman who presented an atraumatic anterior hip dislocation during a local traditional dance exhibition. The dislocation occurred during a dance step in which extreme hip position in extension and external rotation was held. After urgent closed reduction under general anesthesia, the patient underwent conservative management with a follow-up of 24 months. There were no further dislocation events or sequelae, with the Hip Disability and Osteoarthritis Outcome Score-12 scale score was 100 points at the end of follow-up. CONCLUSIONS Atraumatic hip dislocation is the highest grade and exceptional presentation of hip instability and requires immediate treatment. Conservative treatment is satisfactory, although in case of recurrence or persistent residual symptoms, other treatments are warrant.
Collapse
|
5
|
Unter Ecker N, Kocaoğlu H, Zahar A, Haasper C, Gehrke T, Citak M. What Is the Dislocation and Revision Rate of Dual-mobility Cups Used in Complex Revision THAs? Clin Orthop Relat Res 2021; 479:280-285. [PMID: 32898046 PMCID: PMC7899605 DOI: 10.1097/corr.0000000000001467] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Accepted: 08/03/2020] [Indexed: 01/31/2023]
Abstract
BACKGROUND Dual-mobility cups have been shown to reduce the dislocation risk after THA. Although dual-mobility cups can be a useful strategy to mitigate against recurrent dislocation after revision surgery, few clinical studies have focused on the results of complex revision THAs with extensive bone and soft-tissue loss or in patients who have undergone more than one previous surgical procedure. QUESTIONS/PURPOSES (1) What is the survival free from revision for dislocation of dual-mobility cups used in complex revision THAs? (2) What is the survival free from any dislocation? METHODS Between January 1, 2009 and December 31, 2013, 327 patients underwent a complex revision THA that included an acetabular revision, defined as preexisting massive bone loss in the acetabulum (at least Paprosky Type 2B) and/or proximal femur (at least Paprosky Type 3), substantial gluteal soft-tissue involvement, at least two previous surgical procedures or a one-stage septic revision, or history of dislocation. All 327 complex revision patients received a dual-mobility cup. Of those, 34% (111) were lost to follow-up before 5 years and were not known to have reached a study endpoint (revision for dislocation, and any dislocation) before then, leaving 216 patients for analysis. For patients with bilateral hip surgeries only the first operated hip was included for analysis. The median (range) follow-up duration was 69 months (60 to 110). The primary endpoint was dislocation or re-revision for dislocation. Fifty-six percent (120 of 216) of the patients were women and 44% (96 of 216) were men. The mean age of the patients was 69 ± 9 years. The patients underwent a median of four surgical procedures (1 to 4) before the index procedure (the revision evaluated in this study). A survival analysis was performed using the Kaplan-Meier method; any dislocation or revision for dislocation was determined as the endpoint. RESULTS The dislocation-free survival rates were 96% (95% confidence interval 92 to 98) at 5 years and 82% (95% CI 72 to 89) at 9 years. The overall dislocation rate was 11% (24 of 216 patients) at the final follow-up interval. Survival free of revision for dislocation was 99% (95% CI 96 to 100) at 5 years and 85% (95% CI 75 to 92) at 9 years. CONCLUSIONS Dual-mobility cups used in complex revision THA in this series had a higher rate of dislocation and revision than expected, based on earlier studies of dislocations of these components. Although we believe dual-mobility cups are still the first choice of implant if the patient has instability, these cups should be used cautiously if severe bone loss or soft-tissue involvement is present. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
Affiliation(s)
- Niklas Unter Ecker
- N. U. Ecker, H. Kocaoğlu, C. Haasper, T. Gehrke, M. Citak, Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- H. Kocaoğlu, Department of Orthopedics and Traumatology, Ankara University Faculty of Medicine, Ankara, Turkey
- A. Zahar, Department of Orthopaedic Surgery, Helios Klinik Berlin- Zehlendorf, Berlin, Germany
| | - Hakan Kocaoğlu
- N. U. Ecker, H. Kocaoğlu, C. Haasper, T. Gehrke, M. Citak, Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- H. Kocaoğlu, Department of Orthopedics and Traumatology, Ankara University Faculty of Medicine, Ankara, Turkey
- A. Zahar, Department of Orthopaedic Surgery, Helios Klinik Berlin- Zehlendorf, Berlin, Germany
| | - Akos Zahar
- N. U. Ecker, H. Kocaoğlu, C. Haasper, T. Gehrke, M. Citak, Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- H. Kocaoğlu, Department of Orthopedics and Traumatology, Ankara University Faculty of Medicine, Ankara, Turkey
- A. Zahar, Department of Orthopaedic Surgery, Helios Klinik Berlin- Zehlendorf, Berlin, Germany
| | - Carl Haasper
- N. U. Ecker, H. Kocaoğlu, C. Haasper, T. Gehrke, M. Citak, Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- H. Kocaoğlu, Department of Orthopedics and Traumatology, Ankara University Faculty of Medicine, Ankara, Turkey
- A. Zahar, Department of Orthopaedic Surgery, Helios Klinik Berlin- Zehlendorf, Berlin, Germany
| | - Thorsten Gehrke
- N. U. Ecker, H. Kocaoğlu, C. Haasper, T. Gehrke, M. Citak, Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- H. Kocaoğlu, Department of Orthopedics and Traumatology, Ankara University Faculty of Medicine, Ankara, Turkey
- A. Zahar, Department of Orthopaedic Surgery, Helios Klinik Berlin- Zehlendorf, Berlin, Germany
| | - Mustafa Citak
- N. U. Ecker, H. Kocaoğlu, C. Haasper, T. Gehrke, M. Citak, Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- H. Kocaoğlu, Department of Orthopedics and Traumatology, Ankara University Faculty of Medicine, Ankara, Turkey
- A. Zahar, Department of Orthopaedic Surgery, Helios Klinik Berlin- Zehlendorf, Berlin, Germany
| |
Collapse
|
6
|
D'Apolito R, Bandettini G, Jacquot FMP, Zagra L. Modular dual-mobility cups using ceramic liners: an original solution for selected indications? Hip Int 2020; 30:59-65. [PMID: 33267689 DOI: 10.1177/1120700020964976] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Dual mobility (DM) has been shown to improve stability both in primary and revision total hip arthroplasty (THA) and is increasingly used in patients at high risk of dislocation and in the treatment of THA instability. The introduction of modular liners has helped to overcome some of the limitations of monoblock DM cups. In this context, the use of a ceramic liner would avoid the conventional cobalt-chromium liner in the titanium shell, which can be problematic in some situations. The aim of this paper is to report the outcomes of a consecutive series of patients undergoing revision THA using a modular DM cup with a ceramic liner instead of the conventional metal one, and to clarify the rationale for this currently "off-label" use. PATIENTS AND METHODS This is a retrospective series of patients who received this new DM bearing in a single institution. Patients were followed up clinically and radiologically at 1 month, 3 months, 6 months and yearly thereafter. RESULTS 5 patients received the ceramic liner in the study period (2014-2019). The indications were instability or high risk of dislocation in ceramic liner fracture and ARMD with soft tissue damage after MoM THA. The mean age at surgery was 74 (63-82) years, the mean follow-up was 36 (12-72) months. No dislocation occurred, and no adverse events related to the implant were recorded. CONCLUSIONS The use of a ceramic liner in a modular DM cup offers several advantages in selected patients, and the results of our cohort are encouraging. However, caution is needed in introducing this new bearing because knowledge is currently limited. Further studies on a larger number of patients and with longer follow-ups are needed to confirm these findings and before widespread use of the device.
Collapse
Affiliation(s)
- Rocco D'Apolito
- IRCCS Istituto Ortopedico Galeazzi, Hip Department, Milan, Italy
| | - Guido Bandettini
- IRCCS Istituto Ortopedico Galeazzi, Hip Department, Milan, Italy
| | | | - Luigi Zagra
- IRCCS Istituto Ortopedico Galeazzi, Hip Department, Milan, Italy
| |
Collapse
|
7
|
Abstract
INTRODUCTION Dislocation after total hip arthroplasty (THA) is the most common cause of revision hip surgery in the United States, ahead of aseptic loosening and infection, and is responsible for considerable economic cost related to frequent readmission and/or revision surgery. The aim of this article is to identify the clinical and radiological factors related to the unstable total hip replacement. METHODS We performed a literature search to assess current strategies to define clinical and radiological characteristics of dislocation after primary THA using the PubMed platform. The characteristics related to THA instability were divided into patient related factors, implant related factors and surgeon experience. RESULTS Patient-related factors for instability identified are: age; inflammatory joint disease; prior hip surgery; preoperative diagnosis; comorbidity; ASA score; presence of spino-pelvic abnormality; and neurological disability. Gender, simultaneous bilateral THA and restrictive postoperative precautions do not influence rate of THA dislocation. Implant related factors identified are: surgical approach; component malposition; femoral head size; and the use of dual-mobility or constrained solution. Surgeon experience also reduces the rate of dislocation. DISCUSSION Dislocation is a major complication of THAs, and causes include patient-derived factors, surgical factors, or both. It is imperative to determine the cause of the instability via a complete patient and radiographic evaluation and to adjust the reconstruction strategy accordingly.
Collapse
Affiliation(s)
- Loris Perticarini
- Orthopaedic and Traumatology, Fondazione Poliambulanza, Brescia, Italy
| | - Stefano M P Rossi
- Orthopaedic and Traumatology, Fondazione Poliambulanza, Brescia, Italy
| | - Francesco Benazzo
- Orthopaedic and Traumatology, Fondazione Poliambulanza, Brescia, Italy
| |
Collapse
|
8
|
D'Angelo F, Zagra L, Moretti B, Virgilio A, Mazzacane M, Solarino G. Retrospective multi-centre study on head adapters in partial revision hip arthroplasty. Hip Int 2020; 30:72-76. [PMID: 33267683 DOI: 10.1177/1120700020964995] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Instability and dislocation after total hip arthroplasty (THA) is a common reason for revision surgery. THA head-neck adapters promise the reconstruction of optimal femoral offset and leg length in revision THA (rTHA) while retaining stable implants. The aim of this retrospective multi-centre study is to report on the results achieved with the use of head adapters in partial rTHA, to avoid the instability of the implant. METHODS 55 cases of partial rTHA performed between February 2015 and April 2017 in 3 different hospitals using the Bioball Head Adapter (BHA) (Bioball Merete, Medical GmbH, Berlin, Germany) were retrospectively recorded. All patients were evaluated from a radiological point of view at an average follow-up of 3.5 years. Failure was defined as re-revision surgery for any cause as well as a subjective feeling of instability of the joint. RESULTS One failure was registered in an extreme case and radiological findings show no suggestive signs of radiolucencies or loosening and therefore all implants have been considered stable. CONCLUSIONS Despite some limitations of this retrospective study and according to the relevant literature, our data confirms that BHA is a safe system that allows the flexibility to restore femoral offset and version, to adjust leg length, to minimise instability, to avoid unnecessary removal of otherwise well-fixed components thus improving tribology and reducing the risk of taper junction issues without major complications in partial rTHA.
Collapse
Affiliation(s)
- Fabio D'Angelo
- Department of Biotechnology and Life Sciences (DBSV), Division of Orthopaedics and Traumatology, University of Insubria, Varese, Italy
| | - Luigi Zagra
- Hip Department, IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
| | - Biagio Moretti
- Orthopaedics and Traumatology Unit, Department of Basic Medical Sciences, Neuroscience and Sense Organs, University of Bari "Aldo Moro", Bari, Italy
| | - Antonio Virgilio
- Orthopaedics and Traumatology Unit, Department of Basic Medical Sciences, Neuroscience and Sense Organs, University of Bari "Aldo Moro", Bari, Italy
| | - Michael Mazzacane
- Department of Biotechnology and Life Sciences (DBSV), Division of Orthopaedics and Traumatology, University of Insubria, Varese, Italy
| | - Giuseppe Solarino
- Orthopaedics and Traumatology Unit, Department of Basic Medical Sciences, Neuroscience and Sense Organs, University of Bari "Aldo Moro", Bari, Italy
| |
Collapse
|
9
|
Nessler JM, Nessler JP. The Patient With Chronic Total Hip Arthroplasty Dislocations: A Case Series of Five Patients Who Underwent Revision THA Using Polypropylene Mesh for Capsular Reconstruction. Arthroplast Today 2020; 6:655-661. [PMID: 32875015 PMCID: PMC7451887 DOI: 10.1016/j.artd.2020.07.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 07/15/2020] [Accepted: 07/19/2020] [Indexed: 11/18/2022] Open
Abstract
We report a case series of 5 patients who underwent revision total hip arthroplasty (THA) using a polypropylene mesh for capsular reconstruction for chronic THA instability. The average follow-up is 16.6 months (range, 9-20 months). There were no postoperative dislocations in our series. Three patients had previous infections with two-stage revisions before final revision surgery and were infection free at their most recent follow-up. One patient developed a prosthetic joint infection 2 months postoperatively. The use of a polypropylene mesh appears to be another tool that surgeons can use when dealing with the difficult dilemma on how to treat the patient with chronic THA instability and severe abductor and capsular tissue loss.
Collapse
Affiliation(s)
- Joseph M. Nessler
- Department of Orthopedics and Rehabilitation, University of Wisconsin, Madison, WI, USA
| | | |
Collapse
|
10
|
Abstract
Choice of articulating materials, head size and the design of the articulation will become decisive for the long-term performance of a total hip arthroplasty (THA) and especially in terms of risk for dislocation and wear-related problems. Here we account for common alternatives based on available studies and the evidence that can be derived from them.Metal or ceramic femoral heads articulating against a liner or cup made of highly cross-linked polyethylene and ceramic-on-ceramic articulations have about similar risk for complications leading to revision, whereas the performance of metal-on-metal articulations, especially with use of big heads, is inferior. The clinical significance of problems related to ceramic-on-ceramic articulations such as squeaking remains unclear. With use of current technology ceramic fractures are rare.Large femoral heads have the potential to increase the range of hip movement before impingement occurs and are therefore expected to reduce dislocation rates. On the other hand, issues related to bearing wear, corrosion at the taper-trunnion junction and groin pain may arise with larger heads and jeopardize the longevity of THA. Based on current knowledge, 32-mm heads seem to be optimal for metal-on-polyethylene bearings. Patients with ceramic-on-ceramic bearings may benefit from even larger heads such as 36 or 40 mm, but so far there are no long-term reports that confirm the safety of bearings larger than 36 mm.Assessment of lipped liners is difficult because randomized studies are lacking, but retrospective clinical studies and registry data seem to indicate that this liner modification will reduce the rate of dislocation or revision due to dislocation without clear evidence of clinically obvious problems due to neck-liner impingement.The majority of studies support the view that constrained liners and dual mobility cups (DMC) will reduce the risk of revision due to dislocation both in primary and revision THA, the latter gaining increasing popularity in some countries. Both these devices suffer from implant-specific problems, which seem to be more common for the constrained liner designs. The majority of studies of these implants suffer from various methodological problems, not least selection bias, which calls for randomized studies preferably in a multi-centre setting to obtain sufficient power. In the 2020s, the orthopaedic profession should place more effort on such studies, as has already been achieved within other medical specialties, to improve the level of evidence in the choice of articulation when performing one of the most common in-hospital surgical procedures in Europe. Cite this article: EFORT Open Rev 2020;5:763-775. DOI: 10.1302/2058-5241.5.200002.
Collapse
Affiliation(s)
- Georgios Tsikandylakis
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
- Region Västra Götaland, Sahlgrenska University Hospital, Department of Orthopaedics, Gothenburg, Sweden
| | - Soren Overgaard
- The Danish Hip Arthroplasty Register, Aarhus, Denmark
- Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark
- Institute of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Luigi Zagra
- Hip Department, IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
| | - Johan Kärrholm
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
- Region Västra Götaland, Sahlgrenska University Hospital, Department of Orthopaedics, Gothenburg, Sweden
- The Swedish Hip Arthroplasty Register, Gothenburg, Sweden
| |
Collapse
|
11
|
Novel Constrained Dual Mobility Hip Prosthesis to Combat Instability in Revision Total Hip Arthroplasty whilst Preserving Normal Function. Case Rep Orthop 2020; 2020:6390310. [PMID: 32724692 PMCID: PMC7364194 DOI: 10.1155/2020/6390310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Revised: 06/26/2020] [Accepted: 06/30/2020] [Indexed: 12/04/2022] Open
Abstract
We present the case of a male patient with sepsis and a chronic discharging sinus in a multirevised total hip replacement. Following extensive debridement, the reimplanted hip became unstable. With the patient's long-term desire to return to work and ride a bicycle with his children, the patient agreed to proceed with a novel, custom-designed, constrained dual mobility liner which allowed unrestricted movement. In 2017, the patient underwent revision surgery with this novel dual mobility constrained prosthesis. The patient was very quickly able to regain independence. After 16 years of unemployment, he managed to return to gainful employment as a cleaner rapidly regaining function as well as finally being able to ride a bike with his children for the first time.
Collapse
|
12
|
Van Eecke E, Vanbiervliet J, Dauwe J, Mulier M. Comparison of Constrained Acetabular Components and Dual Mobility Cups in Revision Total Hip Arthroplasty: A Literature Review. Hip Pelvis 2020; 32:59-69. [PMID: 32566536 PMCID: PMC7295616 DOI: 10.5371/hp.2020.32.2.59] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2019] [Revised: 10/10/2019] [Accepted: 10/23/2019] [Indexed: 12/26/2022] Open
Abstract
Recurrent instability remains a common cause of failure after revision total hip arthroplasty (THA). Dual mobility (DM) cups and designs with constrained acetabular liners (CAL) have both been developed to help overcome this challenge. The aim of this report is to compare safety and efficacy outcomes of both designs based on the literature. A comprehensive literature review including published evidence on the results of DM and CAL in revision THA was performed and summarized. Available literature focusing on overall survival, dislocation, loosening, intra-prosthetic dislocation (IPD), and functional outcomes were analysed. Forty-six reports including an evaluation of 5,617 total hips were evaluated were included in the review. The included studies were divided into two distinct groups based on implantation approach: i) CAL (n=15) and ii) DM (n=31). The DM group had higher overall survival rates (94.7% vs. 81.0%), lower dislocation rates (2.6% vs. 11.0%), and lower acetabular loosening rates (1.0% vs. 2.0%) compared to the CAL group. IPDs were reported in 6 studies (mean rate, 0.6%). No differences in functional outcomes were identified due to incomplete reports. Our observations reveal that designs with CAL have poorer outcomes as compared to DM cups in revision THA. Currently, the use of DM seems more appropriate since they offer lower rates of dislocations, loosening and re-revisions in the short- and mid-term. Concerns regarding the potential of increased wear in a younger, high-demand population require additional data and evaluation by long-term studies for the DM design.
Collapse
Affiliation(s)
- Eduard Van Eecke
- Department of Orthopedic Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Jens Vanbiervliet
- Department of Orthopedic Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Jan Dauwe
- Department of Orthopedic Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Michiel Mulier
- Department of Orthopedic Surgery, University Hospitals Leuven, Leuven, Belgium
| |
Collapse
|
13
|
Civinini R, Cozzi Lepri A, Carulli C, Matassi F, Villano M, Innocenti M. Patients Following Revision Total Hip Arthroplasty With Modular Dual Mobility Components and Cobalt-Chromium Inner Metal Head are at Risk of Increased Serum Metal Ion Levels. J Arthroplasty 2020; 35:S294-S298. [PMID: 32197964 DOI: 10.1016/j.arth.2020.02.050] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2019] [Revised: 02/14/2020] [Accepted: 02/24/2020] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Modular dual-mobility (MDM) total hip arthroplasty (THA) is designed with a cobalt-chromium liner inserted into a titanium acetabular component. The purpose of this study is to investigate the potential risks for fretting corrosion at this junction, by measuring serum metal ions, after MDM acetabular revision. METHODS Thirty-seven patients with well-functioning revision THAs participated in a cross-sectional study at mean 5.1 (2-10) years after surgery. All received a trabecular titanium MDM acetabular component. The serum levels of cobalt and chromium were measured using mass spectrometry. RESULTS The mean values of chromium and cobalt were 2.08 μg/L (95% confidence interval 0.9-3.2, range 0.02-11.8) and 1.99 μg/L (95% confidence interval 0.81-3.17, range 0.07-16.05), respectively. Eleven patients (29, 7%) had ion levels above the normal range, with 6 (16.2%) above 5 μg/L and 5 (13.5%) between 1 and 5 μg/L. A significant correlation was found between an elevated serum metal ion level and University of California Los Angeles score (P = .016). CONCLUSION We conclude that serum metal level elevation may occur secondary to metal debris resulting from corrosion of the index MDM THA. This potential risk should be included in the decision-making process when dealing with revision arthroplasty in young and active patients.
Collapse
Affiliation(s)
- Roberto Civinini
- Orthopedic Unit, Department of Health Sciences, University of Florence, Firenze, Italy
| | - Andrea Cozzi Lepri
- Orthopedic Unit, Department of Health Sciences, University of Florence, Firenze, Italy
| | - Christian Carulli
- Orthopedic Unit, Department of Health Sciences, University of Florence, Firenze, Italy
| | - Fabrizio Matassi
- Orthopedic Unit, Department of Health Sciences, University of Florence, Firenze, Italy
| | - Marco Villano
- Orthopedic Unit, Department of Health Sciences, University of Florence, Firenze, Italy
| | - Massimo Innocenti
- Orthopedic Unit, Department of Health Sciences, University of Florence, Firenze, Italy
| |
Collapse
|
14
|
Vigdorchik J, Eftekhary N, Elbuluk A, Abdel MP, Buckland AJ, Schwarzkopf RS, Jerabek SA, Mayman DJ. Evaluation of the spine is critical in the workup of recurrent instability after total hip arthroplasty. Bone Joint J 2019; 101-B:817-823. [PMID: 31256675 DOI: 10.1302/0301-620x.101b7.bjj-2018-1502.r1] [Citation(s) in RCA: 60] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS While previously underappreciated, factors related to the spine contribute substantially to the risk of dislocation following total hip arthroplasty (THA). These factors must be taken into consideration during preoperative planning for revision THA due to recurrent instability. We developed a protocol to assess the functional position of the spine, the significance of these findings, and how to address different pathologies at the time of revision THA. PATIENTS AND METHODS Prospectively collected data on 111 patients undergoing revision THA for recurrent instability from January 2014 to January 2017 at two institutions were included (protocol group) and matched 1:1 to 111 revisions specifically performed for instability not using this protocol (control group). Mean follow-up was 2.8 years. Protocol patients underwent standardized preoperative imaging including supine and standing anteroposterior (AP) pelvis and lateral radiographs. Each case was scored according to the Hip-Spine Classification in Revision THA. RESULTS Survival free of dislocation at two years was 97% in the protocol group (three dislocations, all within three months of surgery) versus 84% in the control group (18 patients). Furthermore, 77% of the inappropriately positioned acetabular components would have been unrecognized by supine AP pelvis imaging alone. CONCLUSION Using the Hip-Spine Classification System in revision THA, we demonstrated a significant decrease in the risk of recurrent instability compared with a control group. Without the use of this algorithm, 77% of inappropriately positioned acetabular components would have been unrecognized and incorrect treatment may have been instituted. Cite this article: Bone Joint J 2019;101-B:817-823.
Collapse
Affiliation(s)
- J Vigdorchik
- Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York, USA
| | - N Eftekhary
- NYU Langone Orthopaedic Hospital, New York, New York, USA
| | - A Elbuluk
- Hospital for Special Surgery, New York, New York, USA
| | - M P Abdel
- Mayo Clinic, Rochester, Minnesota, USA
| | - A J Buckland
- NYU Langone Orthopaedic Hospital, New York, New York, USA
| | | | - S A Jerabek
- Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York, USA
| | - D J Mayman
- Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York, USA
| |
Collapse
|
15
|
A comparative study about the incidence of dislocation and peri-prosthetic fracture between dual mobility versus standard cups after primary total hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2019; 43:2691-2695. [DOI: 10.1007/s00264-018-4279-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2018] [Accepted: 12/18/2018] [Indexed: 01/18/2023]
|
16
|
Deckard ER, Azzam KA, Meneghini RM. Contemporary Dual Mobility Head Penetration at Five Years: Concern for the Additional Convex Bearing Surface? J Arthroplasty 2018; 33:S280-S284. [PMID: 29602536 DOI: 10.1016/j.arth.2018.02.061] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2017] [Revised: 01/28/2018] [Accepted: 02/15/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Dual mobility (DM) bearings are increasingly popular and second-generation designs contain highly cross-linked polyethylene. The purpose of this study is to report head penetration rates in modern DM bearings. METHODS A review of 63 consecutive DM bearings was performed. Radiographs were analyzed for head penetration using Martell methodology at regular postoperative intervals. RESULTS Thirty-four DM bearings were analyzed. Mean linear head penetration was 1.59 mm/y at 1 year, 1.07 mm/y at 2 years, and 0.27 mm/y at 5 years following an exponential regression model (R2 = 0.999). Mean volumetric wear was 783 mm3/y at 1 year, 555 mm3/y at 2 years, and 104 mm3/y at 5 years following an exponential regression model (R2 = 0.986). CONCLUSION Initial head penetration of DM bearings is larger than contemporary cross-linked polyethylene bearings; however, rates approach steady state after 2 years, analogous to traditional bearings. The larger "bedding-in" head penetration may be due to the additional convex bearing surface, creating 2 surfaces for deformation/wear.
Collapse
Affiliation(s)
- Evan R Deckard
- Indiana University School of Medicine, Department of Orthopaedic Surgery, Indianapolis, Indiana
| | - Khalid A Azzam
- Indiana University School of Medicine, Department of Orthopaedic Surgery, Indianapolis, Indiana; Indiana University Health Physicians, Orthopedics & Sports Medicine, IU Health Hip & Knee Center, Fishers, Indiana
| | - R Michael Meneghini
- Indiana University School of Medicine, Department of Orthopaedic Surgery, Indianapolis, Indiana; Indiana University Health Physicians, Orthopedics & Sports Medicine, IU Health Hip & Knee Center, Fishers, Indiana
| |
Collapse
|
17
|
Giardina F, Castagnini F, Stea S, Bordini B, Montalti M, Toni A. Short Stems Versus Conventional Stems in Cementless Total Hip Arthroplasty: A Long-Term Registry Study. J Arthroplasty 2018; 33:1794-1799. [PMID: 29395723 DOI: 10.1016/j.arth.2018.01.005] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2017] [Revised: 12/26/2017] [Accepted: 01/05/2018] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND Short stems in total hip arthroplasty (THA) have recently gained increasing popularity, allowing mini-invasive exposures and bone-sparing approaches. However, long-term studies and recommendations for the routine use are not available. The aim of this report was to compare the survival rates and the reasons for revision of short stems versus conventional stems in cementless THAs, in a registry-based population. METHODS The Registry of Prosthetic Orthopedic Implants (RIPO) was inquired about cementless THAs performed since 2000 to 2016. The stems were divided into short (<12 cm) and conventional ones, and then, classified according to the classification by Feyen and Shimmin: short stems with neck-retaining osteotomy (group A: 1684 hips), short stems with standard osteotomy (group B: 2727 THAs), and conventional stems (group C: 57,359 cases). Demographics, survivorships, and reasons for revision were investigated and compared. RESULTS Short stems were preferentially implanted in younger patients and normal morphologies. Short and conventional stems showed comparable survival rates at long-term follow-up (>90% at 15 years). The rates of stem aseptic loosening, intraoperative fractures, and periprosthetic fractures were similar in the 3 groups. Group B had higher rates of revisions due to primary instability (early dislocations and impingement-related events; P < .05). Revisions due to pain were nonsignificantly higher in group B. CONCLUSION Short stems are reliable implants at long-term follow-up. The comparison with conventional stems showed no additional risk of premature aseptic loosening and intraoperative and periprosthetic fractures. However, the high rate of revisions due to pain and, mostly, primary instability should be investigated in clinical trials.
Collapse
Affiliation(s)
- Federico Giardina
- Hip and Knee Surgery Department, Rizzoli Orthopedic Institute, Bologna, Italy
| | | | - Susanna Stea
- Medical Technology Laboratory, Rizzoli Orthopedic Institute, Bologna, Italy
| | - Barbara Bordini
- Medical Technology Laboratory, Rizzoli Orthopedic Institute, Bologna, Italy
| | - Maurizio Montalti
- Hip and Knee Surgery Department, Rizzoli Orthopedic Institute, Bologna, Italy
| | - Aldo Toni
- Hip and Knee Surgery Department, Rizzoli Orthopedic Institute, Bologna, Italy
| |
Collapse
|
18
|
Comparison of dual mobility cup and other surgical construts used for three hundred and sixty two first time hip revisions due to recurrent dislocations: five year results from Lithuanian arthroplasty register. INTERNATIONAL ORTHOPAEDICS 2017; 42:1015-1020. [PMID: 29196791 DOI: 10.1007/s00264-017-3702-0] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2017] [Accepted: 11/21/2017] [Indexed: 01/15/2023]
Abstract
PURPOSE Recently, there has been increasing interest in the use of dual mobility systems in the treatment of hip instability. The aim of this study was to investigate the re-revision rate of dual mobility cup compared to different surgical concepts when used for first-time hip revisions due to recurrent dislocations. METHODS The data were derived from the Lithuanian Arthroplasty Register. For survival analysis, we used both re-revision for all reasons and for dislocations as an end-point. Cox proportional hazards models were used to analyze the influence of various covariates (age, gender, and implant concept). RESULTS A total of 1388 revisions were recorded from 2011 to 2015, of which 362 were performed due to recurrent dislocation. Of the revisions, 247 were performed using dual mobility cups, while 115 were performed using a variety of other surgical constructs including constrained acetabular cups, conventional cups, femoral head exchanges, stem exchanges or anti-luxation rings. There were 27 re-revisions of which 15 were for additional dislocations. There were only 2% re-revisions due to dislocation with dual mobility vs 9% when using other surgical constructs. Cox regression adjusting for age and gender showed that in the short-term, dual mobility cup had a lower risk of revision due to dislocation as well as for all reasons compared to the other surgical constructs. CONCLUSION In revision of total hip arthroplasties for dislocation, significantly lower short-term re-revision rate was observed for patients revised with dual mobility cup.
Collapse
|
19
|
Caton JH, Ferreira A. Dual-mobility cup: a new French revolution. INTERNATIONAL ORTHOPAEDICS 2017; 41:433-437. [PMID: 28197702 DOI: 10.1007/s00264-017-3420-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2017] [Accepted: 01/26/2017] [Indexed: 01/16/2023]
Affiliation(s)
| | - André Ferreira
- Clinique du Parc, 155 Ter Boulevard de Stalingrad, 69006, Lyon, France.
| |
Collapse
|