Survival and radioclinical evaluation of the Optimys™ short stem at more than 6years' mean follow-up: A retrospective study of 108 cases.
Orthop Traumatol Surg Res 2023;
109:103470. [PMID:
36336294 DOI:
10.1016/j.otsr.2022.103470]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Revised: 08/08/2022] [Accepted: 08/24/2022] [Indexed: 11/06/2022]
Abstract
INTRODUCTION
The short stems developed in recent years offer an interesting alternative to standard long stems. The Optimys™ short stem has been widely studied, but not according to the National Institute for Health and Care Excellence (NICE) criteria. We therefore conducted a retrospective study of Optimys™ at a minimum 5years' follow-up, to assess: (1) survival on NICE criteria, (2) complications, (3) functional results, and (4) subsidence, restoration of offset and bone remodeling.
HYPOTHESIS
Optimys™ shows survival comparable to that of other non-cemented standard and short stems, with a<0.5% per year revision rate or<2.5% at 5years on NICE criteria.
MATERIAL AND METHODS
A single-center retrospective study included 108 Optimys™ stems at a mean 76.5months' follow-up (range: 60-112months). Clinical [Harris, Oxford-12 and forgotten hip (French version: SHO-12) scores] and radiologic data were collected pre- and postoperatively. Analysis focused on implant survival, complications, functional results and radiological results (restoration of offset, bone remodeling, subsidence and osseointegration) and risk factors for stem migration.
RESULTS
At a mean 76.5months' follow-up (range: 60-112months), Optimys™ survival was 97.7% (95% CI: 0.945-1). Oxford and Harris scores improved significantly: respectively, 16.1 vs. 44.7 [Δ=28.598; 95% CI: 27.410-29.785 (p<0.001)] and 45.3 vs. 95 [Δ=49.662; 95% CI: 47.442-51.882 (p<0.001)]. Mean forgotten hip score (SHO-12) at last follow-up was 82.7±19.6 (range: 35.4-100.0). There was 1 case of aseptic revision at 11months for femoral osseointegration defect. Mean subsidence was 1.64mm (range: 0-20.63mm); no predisposing factors could be identified. Femoral offset increased by a mean 2.41±4.53mm (range: -10.10 to 14.70mm).
CONCLUSION
The present study reports good survival for the Optimys™ stem, which meets NICE criteria. Radiologic and clinical results were encouraging, with a low rate of subsidence, comparable to other series, but with increased femoral offset.
LEVEL OF EVIDENCE
IV; retrospective cohort study.