1
|
Hiranaka T, Grasso S, Davey C, Fabbro GD, Ahedi H, Fritsch B, Parker D. Accurate correction with a novel patient-specific instrument for medial opening wedge high tibial osteotomy. J ISAKOS 2025; 12:100859. [PMID: 40194658 DOI: 10.1016/j.jisako.2025.100859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2025] [Revised: 03/06/2025] [Accepted: 03/30/2025] [Indexed: 04/09/2025]
Abstract
INTRODUCTION Patient-specific instruments (PSIs) have been introduced to enhance the accuracy of medial opening wedge high tibial osteotomy (MOWHTO). This study aimed to evaluate the accuracy of a newly developed PSI and its impact on postoperative clinical outcomes. METHODS Forty patients with varus alignment who underwent MOWHTO using the newly developed PSI were retrospectively analyzed for accuracy of correction. Radiographic evaluations, including hip-knee-ankle angle (HKA) and medial proximal tibial angle (MPTA) were performed using long-leg standing radiographs preoperatively and at 6 months postoperatively. Overall error was defined as the difference between the planned and achieved HKA (ΔHKA), while surgical error was defined as the difference between the planned and achieved MPTA (ΔMPTA). Planning error was defined as the difference between overall error and surgical error. For each type of error, positive values indicated over-correction, while negative values indicated under-correction. Knee Injury and Osteoarthritis Outcome Score (KOOS) data were collected and compared between preoperative and 12-month postoperative assessments. RESULTS The mean planned HKA was 182.4° ± 0.3°, and the achieved HKA was 182.6° ± 1.5° (p = 0.382). The mean planned MPTA was 93.1° ± 1.9°, and the achieved MPTA was 92.8° ± 1.9° (p = 0.358). The overall error was 0.2° ± 1.5° (38% under-correction and 62% over-correction). Surgical error (ΔMPTA) averaged -0.3° ± 1.1° (55% under-correction and 45% over-correction), while planning error averaged 0.6° ± 1.1° (30% under-correction and 70% over-correction). All KOOS subscales showed a statistically significant improvement at 12 months postoperatively compared to preoperative scores (p < 0.001). CONCLUSION The newly developed PSI workflow proved to be an accurate method for planning and performing MOWHTO. While overall error was low, the observed tendencies for surgical under-correction and planning over-correction highlight the need for careful consideration of these factors to optimize outcomes in the future. LEVEL OF EVIDENCE Level IV, Retrospective Case Series.
Collapse
Affiliation(s)
- Takaaki Hiranaka
- Sydney Orthopaedic Research Institute, Landmark Orthopaedics, St. Leonards, Sydney, Australia.
| | - Samuel Grasso
- Sydney Orthopaedic Research Institute, Landmark Orthopaedics, St. Leonards, Sydney, Australia
| | - Christopher Davey
- Sydney Orthopaedic Research Institute, Landmark Orthopaedics, St. Leonards, Sydney, Australia
| | - Giacomo Dal Fabbro
- Sydney Orthopaedic Research Institute, Landmark Orthopaedics, St. Leonards, Sydney, Australia
| | - Harbeer Ahedi
- Sydney Orthopaedic Research Institute, Landmark Orthopaedics, St. Leonards, Sydney, Australia
| | - Brett Fritsch
- Sydney Orthopaedic Research Institute, Landmark Orthopaedics, St. Leonards, Sydney, Australia
| | - David Parker
- Sydney Orthopaedic Research Institute, Landmark Orthopaedics, St. Leonards, Sydney, Australia
| |
Collapse
|
2
|
Grillo G, Coelho A, Pelfort X, Fillat‐Gomà F, Figuerola AV, Gil‐Gonzalez S, Peñalver JM, Yela‐Verdú C. 3D-printed patient-specific instrumentation and the freehand technique in high-tibial osteotomy: A prospective cohort-comparative study in an outpatient setting. J Exp Orthop 2025; 12:e70088. [PMID: 39839856 PMCID: PMC11747140 DOI: 10.1002/jeo2.70088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2024] [Revised: 09/20/2024] [Accepted: 09/23/2024] [Indexed: 01/23/2025] Open
Abstract
Purpose Tibial valgus osteotomy has shown to be a successful and cost-effective procedure. The advent of image processing and three-dimensional (3D) printing is an interesting tool for achieving more accurate and reproducible results. The aim of our study was to compare the accuracy of the conventional technique and the use of customized guides in the correction of tibial deformities in tibial varus patients, the surgical and clinical benefits, and the impact of treatment in the outpatient setting. Methods A prospective cohort of 30 patients who underwent tibial valgus osteotomy were selected and randomized into two groups (3D-printed guidewires and conventional techniques). All patients underwent a complete radiological study to plan the surgical procedure. During the surgical procedure, the surgical time and X-ray exposure were analysed. The following results were evaluated: surgical time and X-ray exposure, the correlation between the planned correction and the correction obtained at 3 post-operative months, pre- and post-operative knee injury and osteoarthritis outcome score (KOOS) value at 3 and 12 months, and differences between the two groups in terms of the correction obtained. Results Radiation exposure in the '3D-guide' group was significantly different (8 [±4.51], p < 0.05), whereas surgical time was not significantly different between the control and guide 3D groups (60.69 [±8.89] and 53.43 [±11.69], respectively). At the 3-month follow-up, the post-operative hip-knee-ankle and post-operative mechanical-proximal-tibial angle were not significantly different (p > 0.05). At 3- and 12-month post-surgery, the Knee Injury and Osteoarthritis Outcome Score (KOOS) did not significantly differ between the conventional technique and the 3D-guide technique (p > 0.05). The KOOS at 3 months were 87.86 (±5.64) for the control group and 88.46 (±3.53) for the 3D-guide group, while at 12 months they were 91.5 (±5.72) for the control group and 88.57 (±8.81) for the 3D-guide group. Conclusion Customized 3D-printed guides do not permit better correction or functional results than the conventional technique; rather, they reduce surgical time and intraoperative radiation exposure. Level of Evidence II.
Collapse
Affiliation(s)
- Giovanni Grillo
- Department of Orthopedics and Traumatology, Knee Unit, Parc Taulí Hospital Universitari, Institut d'Investigació I Innovació Parc Taulí (I3PT‐CERCA)Universitat Autònoma Barcelona (UAB)SabadellSpain
- Fondazione Policlinico A. Gemelli Orthopedic DepartmentRomaItaly
| | - Alexandre Coelho
- Department of Orthopedics and Traumatology, Knee Unit, Parc Taulí Hospital Universitari, Institut d'Investigació I Innovació Parc Taulí (I3PT‐CERCA)Universitat Autònoma Barcelona (UAB)SabadellSpain
| | - Xavier Pelfort
- Department of Orthopedics and Traumatology, Knee Unit, Parc Taulí Hospital Universitari, Institut d'Investigació I Innovació Parc Taulí (I3PT‐CERCA)Universitat Autònoma Barcelona (UAB)SabadellSpain
| | - Ferran Fillat‐Gomà
- Department of Orthopedics and Traumatology, Knee Unit, Parc Taulí Hospital Universitari, Institut d'Investigació I Innovació Parc Taulí (I3PT‐CERCA)Universitat Autònoma Barcelona (UAB)SabadellSpain
- 3D Surgical Planning Lab, Parc Taulí Hospital Universitari, Institut d'Investigació I Innovació Parc Taulí (I3PT‐CERCA)Universitat Autònoma de Barcelona (UAB)SabadellSpain
| | - Arnau Verdaguer Figuerola
- Department of Orthopedics and Traumatology, Knee Unit, Parc Taulí Hospital Universitari, Institut d'Investigació I Innovació Parc Taulí (I3PT‐CERCA)Universitat Autònoma Barcelona (UAB)SabadellSpain
| | - Sergi Gil‐Gonzalez
- Department of Orthopedics and Traumatology, Knee Unit, Parc Taulí Hospital Universitari, Institut d'Investigació I Innovació Parc Taulí (I3PT‐CERCA)Universitat Autònoma Barcelona (UAB)SabadellSpain
| | - Juan Manuel Peñalver
- Department of Orthopedics and Traumatology, Knee Unit, Parc Taulí Hospital Universitari, Institut d'Investigació I Innovació Parc Taulí (I3PT‐CERCA)Universitat Autònoma Barcelona (UAB)SabadellSpain
| | - Christian Yela‐Verdú
- Department of Orthopedics and Traumatology, Knee Unit, Parc Taulí Hospital Universitari, Institut d'Investigació I Innovació Parc Taulí (I3PT‐CERCA)Universitat Autònoma Barcelona (UAB)SabadellSpain
| |
Collapse
|
3
|
Onishi S, Iseki T, Kanto R, Ukon R, Kambara S, Yoshiya S, Tachibana T, Nakayama H. Preoperative Joint Line Convergence Angle as an Indicator of Clinical Outcomes and Accuracy of Alignment Correction After Double-Level Osteotomy. Orthop J Sports Med 2024; 12:23259671241274146. [PMID: 39371571 PMCID: PMC11456166 DOI: 10.1177/23259671241274146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Accepted: 03/04/2024] [Indexed: 10/08/2024] Open
Abstract
Background The relationship between postoperative alignment and clinical outcomes after double-level osteotomy (DLO) has not been clarified. Purpose To examine the radiological and clinical outcomes after DLO and specifically evaluate the influence of the joint-line convergence angle (JLCA) on the accuracy of alignment correction and surgical outcomes. Study Design Case-control study; Level of evidence, 3. Methods Included were 74 knees in 51 patients (mean age, 61.0 years) who underwent DLO for varus osteoarthritic knees and who had a minimum of 2 years of follow-up. The target hip-knee-ankle angle (HKAA) for the intended limb alignment was set to 1° valgus. The lateral distal femoral angle, medial proximal tibial angle, JLCA, and HKAA were measured on preoperative and postoperative radiographs. Outliers in alignment correction were defined as a deviation of ≥3° from the originally intended HKAA. Clinical outcomes were assessed using the Knee injury and Osteoarthritis Outcome Score (KOOS). In the data analysis, the influence of the radiological parameters on the postoperative outcomes was statistically assessed. Results Radiological and clinical evaluation at 2-year follow-up showed significant improvement from preoperative values (P < .001). The HKAA was corrected from 13.4°± 3.0° varus preoperatively to 0.5°± 2.8° varus at 2 years, indicating a slight undercorrection. Regarding clinical outcomes, significant pre- to postoperative improvement was found on the KOOS (from 185.0 ± 71.2 to 387.9 ± 70.5; P < .001). Overall, 22 of the 74 knees (29.7%) were deemed to be outliers at the 2-year follow-up (19 knees [25.7%] in undercorrection, 3 knees [4.1%] in overcorrection). Postoperative KOOS values were significantly worse in the outliers than in the nonoutliers (344.4 ± 77.7 vs 405.8 ± 59.3; P < .001), and both pre- and postoperative JLCA was significantly larger in the outlier group. The receiver operating characteristic curve analysis indicated a preoperative cutoff JLCA of 6.0° for predicting postoperative alignment outliers. Conclusion A preoperative JLCA of ≥6° was found to be a significant prognostic factor affecting the radiological and clinical outcomes after DLO for varus osteoarthritic knees by compromising the accuracy of deformity correction, resulting in suboptimal postoperative alignment.
Collapse
Affiliation(s)
- Shintaro Onishi
- Department of Orthopaedic Surgery, Nishinomiya Kaisei Hospital, Nishinomiya, Japan
| | - Tomoya Iseki
- Department of Orthopaedic Surgery, Hyogo Medical University, Nishinomiya, Japan
| | - Ryo Kanto
- Department of Orthopaedic Surgery, Hyogo Medical University, Nishinomiya, Japan
| | - Ryosuke Ukon
- Department of Orthopaedic Surgery, Kawasaki Hospital, Kobe, Japan
| | - Shunichiro Kambara
- Department of Orthopaedic Surgery, Hyogo Medical University, Sasayama Medical Center, Tambasasayama, Japan
| | - Shinichi Yoshiya
- Department of Orthopaedic Surgery, Nishinomiya Kaisei Hospital, Nishinomiya, Japan
| | - Toshiya Tachibana
- Department of Orthopaedic Surgery, Hyogo Medical University, Nishinomiya, Japan
| | - Hiroshi Nakayama
- Department of Orthopaedic Surgery, Hyogo Medical University, Nishinomiya, Japan
| |
Collapse
|
4
|
Özmen E, Baris A, Circi E, Yuksel S, Beytemür O. Finite Element Analysis of Protective Measures against Lateral Hinge Fractures in High-Tibial Osteotomy. Adv Orthop 2024; 2024:5510319. [PMID: 39220812 PMCID: PMC11362574 DOI: 10.1155/2024/5510319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2024] [Accepted: 08/12/2024] [Indexed: 09/04/2024] Open
Abstract
Background Opening wedge high-tibial osteotomy (OWHTO) is widely used for correcting mechanical axis deviations and offloading the medial compartment in unicompartmental osteoarthritis. However, lateral hinge fractures (LHFs) pose a significant complication. This study investigates protective measures to mitigate these fractures, guided by prior observations of mechanical stress impact on LHFs. Purpose The study aims to assess the effectiveness of different protective measures, specifically the use of varying sizes of Kirchner wires and drill holes, in reducing the incidence of LHFs during OWHTO. Study Design. The study employs a quantitative, comparative analysis using a finite element method (FEM) based on computed tomography (CT) scans. Methods Using CT-based FEM, the study compares the impact of different sizes of K-wires (1.6 mm, 2.0 mm, and 2.5 mm) and drill holes (3.2 mm and 4.5 mm) on the mechanical stresses around the hinge area in OWHTO. The models were created from a CT scan of a healthy 33-year-old male, focusing on the force required to open the osteotomy gap and the incidence of cracked shell elements. Results The study found that thicker K-wires increased the force required to open the osteotomy gap, whereas larger apical holes decreased it. The 4.5 mm apical hole model demonstrated significantly fewer cracks compared to the 2.0 mm K-wire model, with no significant difference observed compared to the 2.5 mm K-wire model. Models using a 1.6 mm K-wire or a 3.2 mm drill hole did not significantly reduce cracks compared to the base model. Conclusions The findings suggest that a 4.5 mm drill hole may be more effective in reducing the risk of LHFs compared to thinner diameter K-wires or smaller apical holes. Both a 2.5 mm K-wire and a 4.5 mm drill hole reduce the number of cracked elements, but the 4.5 mm drill hole also significantly decreases the average and maximum principal stresses as well as the average tensile strength ratio at the hinge area. These findings may be important for surgical planning, particularly in cases requiring increased osteotomy distraction.
Collapse
Affiliation(s)
- Emre Özmen
- Istanbul Physical Treatment and Rehabilitation Training and Research Hospital, Istanbul, Türkiye
| | - Alican Baris
- Istanbul Physical Treatment and Rehabilitation Training and Research Hospital, Istanbul, Türkiye
| | - Esra Circi
- Istanbul Physical Treatment and Rehabilitation Training and Research Hospital, Istanbul, Türkiye
| | - Serdar Yuksel
- Istanbul Physical Treatment and Rehabilitation Training and Research Hospital, Istanbul, Türkiye
| | - Ozan Beytemür
- SBU Bagcilar Training and Research Hospital, Istanbul, Türkiye
| |
Collapse
|
5
|
Guo H, Pan N, Yang B, Ma M, Wu D, Li C, Zhu R, Wang M, Zhu Y, Zhang Y, Wang J. Clinical outcomes of guider-assisted osteotomy compared to conventional pendulum-saw osteotomy in open wedge high tibial osteotomy: a propensity score-matched cohort study. J Orthop Surg Res 2024; 19:432. [PMID: 39054455 PMCID: PMC11271211 DOI: 10.1186/s13018-024-04909-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Accepted: 07/09/2024] [Indexed: 07/27/2024] Open
Abstract
PURPOSE We developed a novel guider-assisted osteotomy (GAO) procedure to improve the safety of open wedge high tibial osteotomy (OWHTO) and aimed to compare its efficacy and complications with the conventional pendulum-saw osteotomy (PSO). METHODS This is a retrospective cohort study of patients undergoing either GAO or PSO procedure in the OWHTO to treat varus knee osteoarthritis, who had a minimum of 2 years of follow-up. Patients were propensity score matched (PSM) in a 1:1 ratio based on demographic and clinical data with a caliper width of 0.02. The outcomes assessed involved the hospital for special surgery (HSS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and the Intraoperative and postoperative complications. RESULTS 199 patients were included in each group after PSM. The mean duration of follow-up was 38.3 ± 8.9 months. The GAO group had a shorter operation duration (104.5 ± 35.7 vs. 112.1 ± 36.0 min, p = 0.027) and fewer times of intraoperative fluoroscopy (4.2 ± 1.4 vs. 6.0 ± 1.4, p < 0.001). At the last follow-up, clinical scores for knee achieved significant improvements in both GAO and PSO groups: HSS (67.5 ± 10.5 vs. 90.2 ± 7.0, p < 0.001; 69.4 ± 8.2 vs. 91.7 ± 6.8, p < 0.001) and WOMAC (65.7 ± 11.6 vs. 25.2 ± 10.4, p < 0.001; 63.3 ± 12.2 vs. 23.8 ± 9.5, p < 0.001). However, no significant difference was observed between groups for any measures (p > 0.05). In addition, the intraoperative complications (0.5% vs. 3.5%, p = 0.068) and the postoperative bone delayed union and nonunion (1.0% vs. 4.5%, p = 0.032) were marginally or significantly reduced in the GAO versus PSO group. CONCLUSION GAO demonstrates improvements in intraoperative radiation exposure and complications, with comparable short-term efficacy to PSO, and could be considered a viable alternative in clinical practice.
Collapse
Affiliation(s)
- Haichuan Guo
- Department of Orthopedic Surgery, The 3rd Hospital of Hebei Medical University, Shijiazhuang, 050051, Hebei, P.R. China
- Key Laboratory of Biomechanics of Hebei Province, Orthopedic Research Institute of Hebei Province, Shijiazhuang, 050051, Hebei, P.R. China
| | - Naihao Pan
- Department of Orthopedic Surgery, The 3rd Hospital of Hebei Medical University, Shijiazhuang, 050051, Hebei, P.R. China
- Key Laboratory of Biomechanics of Hebei Province, Orthopedic Research Institute of Hebei Province, Shijiazhuang, 050051, Hebei, P.R. China
| | - Bin Yang
- Department of Orthopedic Surgery, The 3rd Hospital of Hebei Medical University, Shijiazhuang, 050051, Hebei, P.R. China
- Key Laboratory of Biomechanics of Hebei Province, Orthopedic Research Institute of Hebei Province, Shijiazhuang, 050051, Hebei, P.R. China
| | - Meixin Ma
- College of Letters and Science, University of California, Berkeley, CA, 94720, USA
| | - Dongwei Wu
- Department of Orthopedic Surgery, The 3rd Hospital of Hebei Medical University, Shijiazhuang, 050051, Hebei, P.R. China
- Key Laboratory of Biomechanics of Hebei Province, Orthopedic Research Institute of Hebei Province, Shijiazhuang, 050051, Hebei, P.R. China
| | - Chengsi Li
- Department of Orthopedic Surgery, The 3rd Hospital of Hebei Medical University, Shijiazhuang, 050051, Hebei, P.R. China
- Key Laboratory of Biomechanics of Hebei Province, Orthopedic Research Institute of Hebei Province, Shijiazhuang, 050051, Hebei, P.R. China
| | - Ruoxuan Zhu
- Department of Orthopedic Surgery, The 3rd Hospital of Hebei Medical University, Shijiazhuang, 050051, Hebei, P.R. China
- Key Laboratory of Biomechanics of Hebei Province, Orthopedic Research Institute of Hebei Province, Shijiazhuang, 050051, Hebei, P.R. China
| | - Maolin Wang
- Department of Orthopedic Surgery, The 3rd Hospital of Hebei Medical University, Shijiazhuang, 050051, Hebei, P.R. China
- Key Laboratory of Biomechanics of Hebei Province, Orthopedic Research Institute of Hebei Province, Shijiazhuang, 050051, Hebei, P.R. China
| | - Yanbin Zhu
- Department of Orthopedic Surgery, The 3rd Hospital of Hebei Medical University, Shijiazhuang, 050051, Hebei, P.R. China.
- Key Laboratory of Biomechanics of Hebei Province, Orthopedic Research Institute of Hebei Province, Shijiazhuang, 050051, Hebei, P.R. China.
| | - Yingze Zhang
- Department of Orthopedic Surgery, The 3rd Hospital of Hebei Medical University, Shijiazhuang, 050051, Hebei, P.R. China.
- Key Laboratory of Biomechanics of Hebei Province, Orthopedic Research Institute of Hebei Province, Shijiazhuang, 050051, Hebei, P.R. China.
| | - Juan Wang
- Department of Orthopedic Surgery, The 3rd Hospital of Hebei Medical University, Shijiazhuang, 050051, Hebei, P.R. China.
- Key Laboratory of Biomechanics of Hebei Province, Orthopedic Research Institute of Hebei Province, Shijiazhuang, 050051, Hebei, P.R. China.
| |
Collapse
|
6
|
Jung SH, Jung M, Chung K, Kim S, Park J, Lee JH, Lee SH, Choi CH, Kim SH. Factors Causing Unintended Sagittal and Axial Alignment Changes in High Tibial Osteotomy: Comparative 3-Dimensional Analysis of Simulation and Actual Surgery. Am J Sports Med 2024; 52:1543-1553. [PMID: 38616541 DOI: 10.1177/03635465241241539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/16/2024]
Abstract
BACKGROUND Unintended secondary changes in the posterior tibial slope (PTS) and tibial torsion angle (TTA) may occur after medial open-wedge high tibial osteotomy (MOWHTO). In surgical procedures using patient-specific instruments (PSIs), it is essential to reproduce the PTS and TTA that were planned in simulations. PURPOSE To analyze the factors causing unintended sagittal and axial alignment changes after MOWHTO. STUDY DESIGN Case series; Level of evidence, 4. METHODS Overall, 63 patients (70 knees) who underwent MOWHTO using a PSI between June 2020 and June 2023 were retrospectively reviewed. Preoperative and postoperative computed tomography scans were 3-dimensionally reconstructed. Simulated osteotomy was performed so that the weightbearing line could pass through the target point. A PSI gapper was 3-dimensionally printed to fit the posteromedial corner of the osteotomy gap in the simulated HTO model. After MOWHTO using the PSI gapper, the actual postoperative model was compared with the preoperative or simulation model. This assessment included PTS, TTA, hinge axis, and osteotomy-related parameters. Cortical breakage around the lateral hinge was evaluated to assess stability. RESULTS The mean PTS and TTA did not change in the simulation. However, significant changes were observed in the actual postoperative PTS and TTA (change, -2.4°± 2.2° and -3.9°± 4.7°, respectively). The PTS was reduced, while the TTA decreased with internal rotation of the distal fragment. The difference in the axial hinge axis angle (AHA) between the simulation and actual surgery was the factor most correlated with the difference in the PTS (r = 0.625; P < .001). In regression analysis, the difference in the AHA was the only factor associated with the difference in the PTS (β = 0.558; P = .001), and there were no factors that showed any significant associations with the difference in the TTA. In subgroup analyses for the change in the TTA, the correction angle and anterior osteotomy angle were significantly higher in the more internal rotation group (P = .023 and P = .010, respectively). The TTA change was significantly higher in the unstable group with lateral cortical breakage (P = .018). The unstable group was more likely to show an internal rotation of ≥5° (odds ratio, 5.0; P = .007). CONCLUSION The AHA was associated with a difference in the PTS between the simulation and actual surgery. The change in the TTA was caused by a combination of multiple factors, such as a large correction angle and anterior osteotomy angle, but mainly by instability of the lateral cortical hinge.
Collapse
Affiliation(s)
- Se-Han Jung
- Arthroscopy and Joint Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
- Department of Orthopedic Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Min Jung
- Arthroscopy and Joint Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
- Department of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Kwangho Chung
- Arthroscopy and Joint Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
- Department of Orthopedic Surgery, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Republic of Korea
| | - Sungjun Kim
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Jisoo Park
- Arthroscopy and Joint Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
- Department of Orthopedic Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Ju-Hyung Lee
- Department of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - So-Heun Lee
- Department of Medical Device Engineering and Management, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Chong-Hyuk Choi
- Arthroscopy and Joint Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
- Department of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Sung-Hwan Kim
- Arthroscopy and Joint Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
- Department of Orthopedic Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
7
|
Veerman QW, ten Heggeler RM, Tuijthof GJ, de Graaff F, Fluit R, Hoogeslag RA. Three-Dimensional Hinge Axis Orientation Contributes to Simultaneous Alignment Correction in All Three Anatomical Planes in Opening-Wedge High Tibial Osteotomy. Arthrosc Sports Med Rehabil 2024; 6:100888. [PMID: 38356465 PMCID: PMC10864846 DOI: 10.1016/j.asmr.2024.100888] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Accepted: 01/02/2024] [Indexed: 02/16/2024] Open
Abstract
Purpose To investigate the simultaneous effect of 3-dimensional (3D) hinge axis (HA) orientation on alignment parameters in all 3 anatomical planes in high tibial osteotomy. Methods A computed tomography-based 3D model of a human tibia/fibula was used to establish a 3D tibial coordinate system based on the tibial mechanical axis. In here, an HA was positioned and an opening-wedge high tibial osteotomy with a rotation angle of 10° over the HA was simulated. HA rotation in the axial plane ranged from 0° to 90° and HA tilt relative to the axial plane ranged from -20° to +20°. The study quantified the simultaneous effect of HA orientation on change of alignment parameters in all anatomical reference planes. Results HA rotation within the tibial axial plane between orientations perpendicular to the coronal and sagittal planes primarily affected both coronal and sagittal plane alignment, with an inverse relationship between these planes (range: 0°-9.7°); the effect of HA rotation on the change in axial plane alignment was maximally 0.9°. In contrast, HA tilt relative to the tibial axial plane primarily affected axial alignment (maximum change: 6.9°); the effect on change in both coronal and sagittal plane alignment was maximally 0.6°. Conclusions HA rotation in the tibial axial plane primarily affects sagittal and coronal plane alignment, and HA tilt relative to the tibial axial plane primarily affects axial plane alignment. Clinical Relevance Integrating 3D HA orientation in malalignment planning and correction offers the potential to minimize unintended corrections in nontargeted planes in uniplanar correction osteotomies and to facilitate intentional multiplanar correction with a single osteotomy.
Collapse
Affiliation(s)
- Quinten W.T. Veerman
- OCON Centre for Orthopaedic Surgery and Sports Medicine, Hengelo, the Netherlands
- Faculty of Engineering Technology, University of Twente, Enschede, the Netherlands
| | - Romy M. ten Heggeler
- OCON Centre for Orthopaedic Surgery and Sports Medicine, Hengelo, the Netherlands
- Faculty of Engineering Technology, University of Twente, Enschede, the Netherlands
| | | | - Feike de Graaff
- OCON Centre for Orthopaedic Surgery and Sports Medicine, Hengelo, the Netherlands
| | - René Fluit
- Faculty of Science and Engineering, University of Groningen, Groningen, the Netherlands
| | - Roy A.G. Hoogeslag
- OCON Centre for Orthopaedic Surgery and Sports Medicine, Hengelo, the Netherlands
| |
Collapse
|
8
|
Mabrouk A, Risebury M, Yasen S. High survivorship and low complication rate in a single-centre series of 651 medial opening wedge high tibial osteotomy cases with a mean follow-up of 13 years. Knee Surg Sports Traumatol Arthrosc 2024; 32:736-749. [PMID: 38410856 DOI: 10.1002/ksa.12096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Revised: 01/30/2024] [Accepted: 02/01/2024] [Indexed: 02/28/2024]
Abstract
PURPOSE This study aimed to report the early to midterm results of medial opening wedge high tibial osteotomy (MOWHTO) from the largest single-centre osteotomy database. The primary outcomes were reporting the radiological corrections and the functional outcomes represented by multiple patient-reported outcome measures (PROMs). The secondary outcomes were to report the complications, revisions and survivorship up to 10 years postoperatively. METHODS A prospectively maintained single-centre database of 1138 knee osteotomies was retrospectively reviewed. Patients who underwent MOWHTO and met the inclusion criteria were included. Those inclusion criteria were moderate to severe knee pain that failed conservative management; varus knee malalignment; and isolated medial osteoarthritis of the knee. A total of 651 cases, with a mean age of 46.7 ± 9 years and a mean body mass index of 29.6 ± 5.2 kg/m2 , were included. This comprised 71% males (n = 462) and 29% females (n = 189). The mean follow-up was 158.1 ± 45.4 months. Multiple PROMs were recorded preoperatively and serially postoperatively. This included the Knee injury and Osteoarthritis Outcome Scores, the Oxford Knee Score, the Oxford Knee Score-Activity and Participation Questionnaire, the Western Ontario and McMaster University Scores, the Visual Analogue Scale for health and pain, and the EQ-5D, which is a standardised measure of health-related quality of life. All lower limb alignment measurements were recorded pre- and postoperatively. The rates of osteotomy revision, conversion to arthroplasty, complications, and 5- and 10-year survivorship were recorded. RESULTS A total of 651 cases were followed up to a mean of 158.1 ± 45.4 months. The mean planned correction angle was 7.6° ± 2.9°. The mean planned opening wedge distance was 8.1 ± 3.1 mm. The mean intraoperative anterior and posterior osteotomy gaps opening were 7.7 ± 3.4 and 8.9 ± 3.8 mm, respectively. Postoperatively, the mean mechanical tibiofemoral angle improved from -5.7° ± 2.9° varus to 1.3° ± 2.5° valgus, the mean medial proximal tibial angle improved from preoperative 85.5° ± 2.3° to postoperative 91.6° ± 2.7° and the mean Mikulicz point improved from 21.7 ± 12.6% to 54.8 ± 11% (all p values < 0.001). All PROMs significantly improved at 24 months follow-up (all p values < 0.001). The rate of osteotomy revision was 1.1% at a mean of 2 ± 2.5 years postoperatively. The overall rate of arthroplasty conversion was 9.1%. This comprised 5.8% total knee arthroplasty conversion at a mean of 6.9 ± 3.5 years postoperatively and 3.2% unicompartmental knee arthroplasty conversion at a mean of 5.7 ± 2.5 years postoperatively. An overall 10.3% complication rate was recorded. The 5 and 10-year survivorship was 97.2% and 91.9%, respectively. CONCLUSION MOWHTO is a radiologically and clinically rewarding procedure with a high survival rate at 5 and 10 years and a low complication rate in experienced hands. MOWHTO should be considered in patients presenting with medial unicompartmental knee pain with an evidence of overload and a varus mechanical coronal plane axis. LEVEL OF EVIDENCE Level IV, retrospective cohort study.
Collapse
Affiliation(s)
- Ahmed Mabrouk
- Department of Trauma and Orthopaedics, Basingstoke and North Hampshire Hospital, Basingstoke, UK
| | - Michael Risebury
- Department of Trauma and Orthopaedics, Basingstoke and North Hampshire Hospital, Basingstoke, UK
| | - Sam Yasen
- Department of Trauma and Orthopaedics, Basingstoke and North Hampshire Hospital, Basingstoke, UK
| |
Collapse
|
9
|
Vlachopoulos L, Fucentese SF. [Osteotomies around the knee: preoperative planning using CT-based three-dimensional analysis, patient-specific cutting and reduction guides]. OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE 2023; 35:225-238. [PMID: 37316574 PMCID: PMC10520128 DOI: 10.1007/s00064-023-00814-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Revised: 02/03/2023] [Accepted: 02/07/2023] [Indexed: 06/16/2023]
Abstract
OBJECTIVE The goal of osteotomy is either to restore pretraumatic anatomic conditions or to shift the load to less affected compartments. INDICATIONS Indications for computer-assisted 3D analysis and the use of patient-specific osteotomy and reduction guides include "simple" deformities and, in particular, multidimensional complex (especially posttraumatic) deformities. CONTRAINDICATIONS General contraindications for performing a computed tomography (CT) scan or for an open approach for performing the surgery. SURGICAL TECHNIQUE Based on CT examinations of the affected and, if necessary, the contralateral healthy extremity as a healthy template (including hip, knee, and ankle joints), 3D computer models are generated, which are used for 3D analysis of the deformity as well as for calculation of the correction parameters. For the exact and simplified intraoperative implementation of the preoperative plan, individualized guides for the osteotomy and the reduction are produced by 3D printing. POSTOPERATIVE MANAGEMENT Partial weight-bearing from the first postoperative day. Increasing load after the first x‑ray control 6 weeks postoperatively. No limitation of the range of motion. RESULTS There are several studies that have analyzed the accuracy of the implementation of the planned correction for corrective osteotomies around the knee joint with the use of patient-specific instruments with promising results.
Collapse
Affiliation(s)
- Lazaros Vlachopoulos
- Klinik für Orthopädie, Universitätsklinik Balgrist, Universität Zürich, Forchstr. 340, 8008, Zürich, Schweiz.
| | - Sandro F Fucentese
- Klinik für Orthopädie, Universitätsklinik Balgrist, Universität Zürich, Forchstr. 340, 8008, Zürich, Schweiz
| |
Collapse
|
10
|
Dasari SP, Hevesi M, Mameri E, Ferrer-Rivero R, Fortier LM, Jackson GR, Warrier AA, Maheshwer B, Jawanda H, Khan ZA, Kerzner B, Browning RB, Gursoy S, Chahla J. Patient-specific instrumentation for medial opening wedge high tibial osteotomies in the management of medial compartment osteoarthritis yields high accuracy and low complication rates: A systematic review. J ISAKOS 2023; 8:163-176. [PMID: 36931505 DOI: 10.1016/j.jisako.2023.02.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 01/15/2023] [Accepted: 02/25/2023] [Indexed: 03/17/2023]
Abstract
IMPORTANCE There has been growing interest in the use of patient-specific instrumentation (PSI) to maximise accuracy and minimise the risk of major complications for medial opening-wedge high tibial osteotomies (MOW-HTOs). Numerous studies have reported the efficacy and safety of implementing this technology into clinical practice, yet no systematic review summarising the clinical literature on PSI for MOW-HTOs has been performed to date. AIM The aim of this investigation was to perform a systematic review summarising the evidence surrounding the use of PSI for MOW-HTOs in the management of medial compartment osteoarthritis. EVIDENCE REVIEW PubMed, Scopus, and the Cochrane Library were queried in October 2021 for studies that used PSI for MOW-HTOs when managing medial compartment knee osteoarthritis. Primary outcomes included accuracy in coronal plane correction (mechanical medial proximal tibial angle), sagittal plane correction (posterior tibial slope), and mechanical axis correction (hip-knee-ankle angle [HKA], mechanical femorotibial angle, and weight-bearing line). Accuracy was defined as error between post-operative measurements relative to the planned pre-operative correction. A secondary outcome was the incidence of major complications. FINDINGS This review included eight different techniques among the 14 included studies. There was a weighted mean error of 0.5° (range: 0.1°-1.3°) for the mechanical medial proximal tibial angle, 0.6° (range: 0.3°-2.7°) for the posterior tibial slope, and 0.8° (range: 0.1°-1.0°) for the hip-knee-ankle angle. Four studies compared the correctional error of the mechanical axis between conventional techniques and PSI techniques. The comparative difference between the two techniques favoured the use of PSI for MOW-HTOs (standardised mean difference = 0.52; 95% confidence interval, 0.16 to 0.87; p = 0.004). Among the 14 studies evaluated, four studies explicitly reported no major complications, while five studies reported a non-zero incidence of major complications. Among these nine studies, the weighted mean major complication rate was 7.1% (range: 0.0-13.0%). CONCLUSIONS AND RELEVANCE The findings of this present systematic review suggest that the use of PSI for MOW-HTOs leads to high accuracy relative to the planned corrections in the coronal plane, sagittal plane, and mechanical axis. Furthermore, these findings would suggest there is a low risk of major complications when implementing PSI for MOW-HTOs. LEVEL OF EVIDENCE Systematic review; IV.
Collapse
Affiliation(s)
- Suhas P Dasari
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Mario Hevesi
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Enzo Mameri
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Robert Ferrer-Rivero
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Luc M Fortier
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Garrett R Jackson
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Alec A Warrier
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Bhargavi Maheshwer
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Harkirat Jawanda
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Zeeshan A Khan
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Benjamin Kerzner
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Robert B Browning
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Safa Gursoy
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Jorge Chahla
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA.
| |
Collapse
|
11
|
Benignus C, Buschner P, Meier MK, Wilken F, Rieger J, Beckmann J. Patient Specific Instruments and Patient Individual Implants—A Narrative Review. J Pers Med 2023; 13:jpm13030426. [PMID: 36983609 PMCID: PMC10051718 DOI: 10.3390/jpm13030426] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 02/20/2023] [Accepted: 02/25/2023] [Indexed: 03/02/2023] Open
Abstract
Joint arthroplasties are one of the most frequently performed standard operations worldwide. Patient individual instruments and patient individual implants represent an innovation that must prove its usefulness in further studies. However, promising results are emerging. Those implants seem to be a benefit especially in revision situations. Most experience is available in the field of knee and hip arthroplasty. Patient-specific instruments for the shoulder and upper ankle are much less common. Patient individual implants combine individual cutting blocks and implants, while patient individual instruments solely use individual cutting blocks in combination with off-the-shelf implants. This review summarizes the current data regarding the implantation of individual implants and the use of individual instruments.
Collapse
Affiliation(s)
- Christian Benignus
- Department of Traumatology and Orthopedic Surgery, Hospital Ludwigsburg, Posilipostr. 4, 71640 Ludwigsburg, Germany
| | - Peter Buschner
- Department of Orthopedic Surgery and Traumatology, Hospital Barmherzige Brüder Munich, Romanstr. 93, 80639 Munich, Germany
| | - Malin Kristin Meier
- Department of Orthopedic Surgery and Traumatology, Inselspital, University Hospital Bern, University of Bern, Freiburgstr. 4, 3010 Bern, Switzerland
| | - Frauke Wilken
- Department of Orthopedic Surgery and Traumatology, Hospital Barmherzige Brüder Munich, Romanstr. 93, 80639 Munich, Germany
| | - Johannes Rieger
- Department of Orthopedic Surgery and Traumatology, Hospital Barmherzige Brüder Munich, Romanstr. 93, 80639 Munich, Germany
| | - Johannes Beckmann
- Department of Orthopedic Surgery and Traumatology, Hospital Barmherzige Brüder Munich, Romanstr. 93, 80639 Munich, Germany
- Correspondence:
| |
Collapse
|
12
|
Attention to Detail: The Effect of Fluoroscopic Parallax on Limb Alignment Assessment During Corrective Osteotomy. J Am Acad Orthop Surg Glob Res Rev 2023; 7:01979360-202302000-00008. [PMID: 36787194 PMCID: PMC9928831 DOI: 10.5435/jaaosglobal-d-22-00289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Accepted: 01/06/2023] [Indexed: 02/15/2023]
Abstract
BACKGROUND The accuracy of a corrective osteotomy is dependent on many factors. One error rarely considered is using noncentered fluoroscopic imaging to assess intraoperative alignment. This study quantified the coronal alignment error produced by visual parallax per interval changes in vertical and horizontal positioning of the C-arm and alignment rod during intraoperative evaluation. METHODS Unilateral hip, ankle, and knee fluoroscopic images were obtained from a single intact cadaveric specimen. A center-center fluoroscopic image was obtained by moving the C-arm appeared in the center square of the nine-box grid. With the base of the C-arm stationary, the radiograph generator/intensifier portion of the C-arm was translated medially until the target bone appeared on the edge of the fluoroscopic image. RESULTS One hundred eight images were obtained. Measurement error increased by an average of 14% per 10 mm of horizontal C-arm offset. Minimal effect was seen if the obtained image was within 5 mm of the true center; however, once 55 mm of offset was reached, all experimental conditions resulted in at least 10 mm of parallax error. CONCLUSION Our results demonstrate that small variations in C-arm positioning can create statistically significant inaccuracies when assessing limb alignment using intraoperative fluoroscopy.
Collapse
|
13
|
Pioger C, Mabrouk A, Siboni R, Jacquet C, Seil R, Ollivier M. Double-level knee osteotomy accurately corrects lower limb deformity and provides satisfactory functional outcomes in bifocal (femur and tibia) valgus malaligned knees. Knee Surg Sports Traumatol Arthrosc 2023:10.1007/s00167-023-07325-y. [PMID: 36705689 DOI: 10.1007/s00167-023-07325-y] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 01/16/2023] [Indexed: 01/28/2023]
Abstract
PURPOSE Double-level knee osteotomy (DLO) is a challenging procedure that requires precision in preoperative planning and intraoperative execution to achieve the desired correction. It is indicated in cases of severe varus or valgus deformities where a single-level osteotomy would yield significantly tilted joint line obliquity (JLO). This study aimed to evaluate the effectiveness of DLO in achieving accurate correction without compromising JLO, using patient-specific cutting guides (PSCGs), in cases of bifocal valgus maligned knees. METHODS A single-centre, retrospective analysis of prospectively collected data for a total of 26 patients, who underwent DLO by PSCGs for valgus malaligned knees, between 2015 and 2020. Post-operative alignment was evaluated and the delta for different lower limb0.05, not statistically significant (ns)). All KOOS subs alignment parameters was calculated; the hip-knee-ankle angle (ΔHKA), medial proximal tibial angle (ΔMPTA), and lateral distal femoral angle (ΔLDFA). At the two-year follow-up, changes in the KOOS sub-scores, UCLA scores, lower limb discrepancy (LLD), and mean time to return to work and sport were recorded. All intraoperative and postoperative complications were recorded. The Mann-Whitney U test with a 95% confidence interval (95% CI) was used to evaluate the differences between two variables; one-way ANOVA between more than two variables and the paired Student's t-test was used to estimate the evolution of functional outcomes. RESULTS The postoperative mean ΔHKA was 0.9 ± 0.9°, the mean ΔMPTA was 0.7 ± 0.7°, and the mean ΔLDFA was 0.7 ± 0.8° (all values with p > 0.05, not statistically significant (ns)). All KOOS subscore's mean values were improved to an extent two-fold superior to the reported minimal clinically important difference (MCID) (all with p < 0.0001). There was a significant increase in the UCLA score at the final follow-up (5.4 ± 1.5 preoperatively versus 7.7 ± 1.4, p < 0.01). The mean time to return to sport and work was 4.7 ± 1.1 and 4.3 ± 2.1 months, respectively. There was an improvement in Lower-limb discrepancy preoperative (LLD = 1.3 ± 2 cm) to postoperative measures (LLD = 0.3 ± 0.4 cm), ns. Complications were 2 femoral hinge fractures, 2 deep vein thromboses, 1 delayed tibial healing, and 1 hardware removal for hamstring irritation syndrome. CONCLUSION DLO is effective and safe in achieving accurate correction in bifocal valgus malaligned knees with maintained lower limb length and low complication rate with no compromise of JLO. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Charles Pioger
- Department of Orthopaedic Surgery, Ambroise Paré Hospital, Paris Saclay University, 9, Avenue Charles de Gaulle, 92100, Boulogne-Billancourt, France.
| | - Ahmed Mabrouk
- Department of Orthopaedic Surgery, Sainte-Marguerite Hospital, Institut du Mouvement de L'Appareil Locomoteur (IML), 19, Avenue Viton, 13009, Marseille, France
| | - Renaud Siboni
- Department of Orthopaedic Surgery, Reims Teaching Hospital, Hôpital Maison Blanche, 45 Rue Cognacq-Jay, 51092, Reims, France
| | - Christophe Jacquet
- Department of Orthopaedic Surgery, Sainte-Marguerite Hospital, Institut du Mouvement de L'Appareil Locomoteur (IML), 19, Avenue Viton, 13009, Marseille, France
| | - Romain Seil
- Department of Orthopaedic Surgery, Centre Hospitalier Luxembourg-Clinique d'Eich, Luxembourg, Luxembourg
| | - Matthieu Ollivier
- Department of Orthopaedic Surgery, Sainte-Marguerite Hospital, Institut du Mouvement de L'Appareil Locomoteur (IML), 19, Avenue Viton, 13009, Marseille, France
| |
Collapse
|
14
|
Pang R, Jiang Z, Xu C, Shi W, Zhang X, Wan X, Bahat D, Li H, Senatov F, Bulygina I, Wang H, Zhang H, Li Z. Is Patient-Specific Instrumentation Accurate and Necessary for Open-Wedge High Tibial Osteotomy? A Meta-Analysis. Orthop Surg 2022; 15:413-422. [PMID: 36585795 PMCID: PMC9891955 DOI: 10.1111/os.13483] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 07/18/2022] [Accepted: 08/09/2022] [Indexed: 01/01/2023] Open
Abstract
The purpose of this meta-analysis was to identify if patient-specific instrumentation (PSI) could increase the accuracy of the correction in high tibial osteotomy (HTO) and to explore the assessment indices and the necessity of using a PSI in HTO. A systematic search was carried out using online databases. A total of 466 patients were included in 11 papers that matched the inclusion criteria. To evaluate the accuracy of PSI-assisted HTO, the weight bearing line ratio (WBL%), hip-knee-ankle angle (HKA), mechanical medial proximal tibial angle (mMPTA), and posterior tibial slope angle (PTSA) were measured preoperatively and postoperatively and compared to the designed target values. Statistical analysis was performed after strict data extraction with Review Manager (version 5.4). Significant differences were detected in WBL% (MD = -36.41; 95% CI: -42.30 to -30.53; p < 0.00001), HKA (MD = -9.95; 95% CI: -11.65 to -8.25; p < 0.00001), and mMPTA (MD = -8.40; 95% CI:-10.27 to -6.53; p < 0.00001) but not in PTSA (MD = 0.34; 95% CI: -0.59 to 1.27; p = 0.47) between preoperative and postoperative measurements. There was no significant difference between the designed target values and the postoperative correction values of HKA (MD = 0.14; 95% CI: -0.19 to 0.47; p = 0.41) or mMPTA (MD = 0.11; 95% CI -0.34 to 0.55; p = 0.64). The data show that 3D-based planning of PSI for HTO is both accurate and safe. WBL%, HKA, and mMPTA were the optimal evaluation indicators of coronal plane correction. Sagittal correction is best evaluated by the PTSA. The present study reports that PSI is accurate but not necessary in typical HTO.
Collapse
Affiliation(s)
- Ran Pang
- Department of OrthopaedicsTianjin Medical University General HospitalTianjinPR China
| | - Zhaohui Jiang
- Department of OrthopaedicsTianjin Medical University General HospitalTianjinPR China
| | - Chunlei Xu
- Department of OrthopaedicsTianjin Medical University General HospitalTianjinPR China
| | - Wei Shi
- Department of OrthopaedicsTianjin Medical University General HospitalTianjinPR China
| | - Xinglong Zhang
- Department of OrthopaedicsTianjin Medical University General HospitalTianjinPR China
| | - Xin Wan
- Department of OrthopaedicsTianjin Medical University General HospitalTianjinPR China
| | - Daniel Bahat
- Department of OrthopaedicsCleveland ClinicClevelandOhioUSA
| | - Hui Li
- Department of OrthopaedicsTianjin Medical University General HospitalTianjinPR China,Department of OrthopaedicsTianjin Hospital of ITCWM Nankai HospitalTianjinPR China
| | - Fedor Senatov
- Center for Biomedical EngineeringNational University of Science and Technology “MISIS”MoscowRussia
| | - Inna Bulygina
- Center for Biomedical EngineeringNational University of Science and Technology “MISIS”MoscowRussia
| | - Hu Wang
- Department of Physical Health Care and RehabilitationTianjin Vocational College of SportsTianjinPR China
| | - Huafeng Zhang
- Department of OrthopaedicsTianjin Medical University General HospitalTianjinPR China
| | - Zhijun Li
- Department of OrthopaedicsTianjin Medical University General HospitalTianjinPR China
| |
Collapse
|
15
|
Zaffagnini S, Dal Fabbro G, Belvedere C, Leardini A, Caravelli S, Lucidi GA, Agostinone P, Mosca M, Neri MP, Grassi A. Custom-Made Devices Represent a Promising Tool to Increase Correction Accuracy of High Tibial Osteotomy: A Systematic Review of the Literature and Presentation of Pilot Cases with a New 3D-Printed System. J Clin Med 2022; 11:jcm11195717. [PMID: 36233583 PMCID: PMC9571741 DOI: 10.3390/jcm11195717] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 09/19/2022] [Accepted: 09/21/2022] [Indexed: 11/17/2022] Open
Abstract
Background: The accuracy of the coronal alignment corrections using conventional high tibial osteotomy (HTO) falls short, and multiplanar deformities of the tibia require consideration of both the coronal and sagittal planes. Patient-specific instrumentations have been introduced to improve the control of the correction. Clear evidence about customized devices for HTO and their correction accuracy lacks. Methods: The databases PUBMED and EMBASE were systematically screened for human and cadaveric studies about the use of customized devices for high tibial osteotomy and their outcomes concerning correction accuracy. Furthermore, a 3D-printed customized system for valgus HTO with three pilot cases at one-year follow-up was presented. Results: 28 studies were included. The most commonly used custom-made devices for HTO were found to be cutting guides. Reported differences between the achieved and targeted correction of hip-knee-ankle angle and the posterior tibial slope were 3° or under. The three pilot cases that underwent personalized HTO with a new 3D-printed device presented satisfactory alignment and clinical outcomes at one-year follow-up. Conclusion: The available patient-specific devices described in the literature, including the one used in the preliminary cases of the current study, showed promising results in increasing the accuracy of correction in HTO procedure.
Collapse
Affiliation(s)
- Stefano Zaffagnini
- 2nd Orthopedics and Trauma Unit, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
- Dipartimento di Scienze Biomediche e Neuromotorie (DIBINEM), University of Bologna, 40126 Bologna, Italy
| | - Giacomo Dal Fabbro
- 2nd Orthopedics and Trauma Unit, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
- Correspondence: ; Tel.: +39-051-636-6075
| | - Claudio Belvedere
- Laboratory of Movement Analysis and Functional Evaluation of Prosthesis, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
| | - Alberto Leardini
- Laboratory of Movement Analysis and Functional Evaluation of Prosthesis, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
| | - Silvio Caravelli
- 2nd Orthopedics and Trauma Unit, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
| | - Gian Andrea Lucidi
- 2nd Orthopedics and Trauma Unit, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
- Dipartimento di Scienze Biomediche e Neuromotorie (DIBINEM), University of Bologna, 40126 Bologna, Italy
| | - Piero Agostinone
- 2nd Orthopedics and Trauma Unit, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
| | - Massimiliano Mosca
- 2nd Orthopedics and Trauma Unit, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
| | - Maria Pia Neri
- 2nd Orthopedics and Trauma Unit, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
| | - Alberto Grassi
- 2nd Orthopedics and Trauma Unit, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
- Dipartimento di Scienze Biomediche e Neuromotorie (DIBINEM), University of Bologna, 40126 Bologna, Italy
| |
Collapse
|
16
|
Aman ZS, DePhillipo NN, Peebles LA, Familiari F, LaPrade RF, Dekker TJ. Improved Accuracy of Coronal Alignment Can Be Attained Using 3D-Printed Patient-Specific Instrumentation for Knee Osteotomies: A Systematic Review of Level III and IV Studies. Arthroscopy 2022; 38:2741-2758. [PMID: 35247513 DOI: 10.1016/j.arthro.2022.02.023] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Revised: 02/18/2022] [Accepted: 02/20/2022] [Indexed: 02/02/2023]
Abstract
PURPOSE To evaluate the accuracy and precision of postoperative coronal plane alignment using 3D-printed patient-specific instrumentation (PSI) in the setting of proximal tibial or distal femoral osteotomies. METHODS A systematic review evaluating the accuracy of 3D-printed PSI for coronal plane alignment correcting knee osteotomies was performed. The primary outcomes were accuracy of coronal plane limb alignment correction and number of correction outliers. Secondary variables were duration of surgery, number of intraoperative fluoroscopic images, complications, cost, and clinical outcomes (as applicable). RESULTS Ninety-three studies were identified, and 14 were included in the final analysis. Overall, mean postoperative deviation from target correction ranged from 0.3° to 1° for all studies using hip-knee angle measurements and 2.3% to 4.9% for all studies using weight-bearing line measurements. The incidence of correction outliers was assessed in 8 total studies and ranged from 0 to 25% (total n = 10 knees) of patients corrected with 3D-printed PSI. Osteotomies performed with 3D-printed cutting guides or wedges demonstrated significantly shorter operative times (P < .05) and fewer intraoperative fluoroscopic images (P < .05) than control groups in four case control studies. CONCLUSION Patients undergoing distal femoral osteotomy or proximal tibial osteotomy procedures with 3D-printed patient-specific cutting guides and wedges had highly accurate coronal plane alignment with a low rate of outliers. Patients treated with 3D printed PSI also demonstrated significantly shorter operative times and decreased intraoperative fluoroscopy when compared to conventional techniques. LEVEL OF EVIDENCE Level IV, systematic review of Level III-IV studies.
Collapse
Affiliation(s)
- Zachary S Aman
- Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, Pennsylvania, U.S.A
| | | | - Liam A Peebles
- Tulane University School of Medicine, New Orleans, Louisiana, U.S.A
| | - Filippo Familiari
- Department of Orthopaedics and Trauma Surgery, Magna Graecia University, Catanzaro, Italy
| | | | | |
Collapse
|
17
|
Abstract
Meniscal lesions often occur in association with anterior cruciate ligament (ACL) tears at the moment of the injury or, secondarily, as a consequence of knee instability. Both ACL and meniscus lesions are associated with a higher risk of osteoarthritis. Adequate treatment of these lesions reduces the rate of degenerative changes in the affected knee. Meniscal tears should be addressed concomitantly with ACL reconstruction and the treatment must be oriented towards preserving the meniscal tissue anytime this is possible. Several options for approaching a meniscus tear are available. The meniscal suture should always be considered, and, if possible, meniscectomy should be the last choice. “Masterly neglect” is a valuable option in selected cases.
Collapse
|
18
|
Miao Z, Li S, Luo D, Lu Q, Liu P. The validity and accuracy of 3D-printed patient-specific instruments for high tibial osteotomy: a cadaveric study. J Orthop Surg Res 2022; 17:62. [PMID: 35093132 PMCID: PMC8800288 DOI: 10.1186/s13018-022-02956-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Accepted: 01/21/2022] [Indexed: 02/06/2023] Open
Abstract
Objective High tibial osteotomy (HTO) has been used for the treatment of patients with knee osteoarthritis. However, the successful implementation of HTO requires precise intraoperative positioning, which places greater requirements on the surgeon. In this study, we aimed to design a new kind of 3D-printed patient-specific instrument (PSI) for HTO, including a positioning device and an angle bracing spacer, and verify its effectiveness using cadaveric specimens. Methods This study included ten fresh human lower-limb cadaveric specimens. Computed tomography (CT) and X-ray examinations were performed to make preoperative plans. PSI was designed and 3D-printed according to the preoperative plan. Then, the PSI was used to guide HTO. Finally, we performed X-ray and CT after the operation to verify its validity and accuracy. Results The PSI using process was adjusted according to the pre-experimental procedure in 1 case. Hinge fracture occurred in 1 case. According to X-rays of the remaining eight cadaveric specimens, no statistically significant difference was noted between the preoperative planning medial proximal tibial angle (MPTA) and postoperative MPTA (P > 0.05) or the preoperative and postoperative posterior slope angle (PSA) (P > 0.05). According to the CT of 10 cadaveric specimens, no statistically significant difference was noted between the design angle and actual angle, which was measured according to the angle between the osteotomized line and the cross section (P > 0.05). The gap between the designed osteotomy line and the actual osteotomy line was 2.09 (0.8 ~ 3.44) mm in the coronal plane and 1.58 (0.7 ~ 2.85) mm in the sagittal plane. Conclusion This 3D-printed PSI of HTO accurately achieves the angle and position of the preoperative plan without increasing the stripping area. However, its use still requires a certain degree of proficiency to avoid complications, such as hinge fracture.
Collapse
|
19
|
Potential New Treatments for Knee OA: A Prospective Review of Registered Trials. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app112211049] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
We aimed to evaluate potential new treatments for knee osteoarthritis (OA). The National Institute of Health ClinicalTrials.gov database was searched for “Osteoarthritis, Knee”. We found 565 ongoing interventional studies with a total planned enrollment of 111,276 subjects. Ongoing studies for knee OA represent a very small fraction of the registered clinical trials, but they are over a quarter of all knee trials and over two thirds of all OA studies. The most researched topic was arthroplasty, with aspects such as implant design changes, cementless fixation, robotic guidance, pain management, and fast track recovery. Intraarticular injections focused on cell therapies with mesenchymal stem cells sourced from adipose tissue, bone marrow, or umbilical cord. We could see the introduction of the first disease modifying drugs with an impact on knee OA, as well as new procedures such as geniculate artery embolization and geniculate nerve ablation.
Collapse
|
20
|
Grasso F, Martz P, Micicoi G, Khakha R, Kley K, Hanak L, Ollivier M, Jacquet C. Double level knee osteotomy using patient-specific cutting guides is accurate and provides satisfactory clinical results: a prospective analysis of a cohort of twenty-two continuous patients. INTERNATIONAL ORTHOPAEDICS 2021; 46:473-479. [PMID: 34536082 DOI: 10.1007/s00264-021-05194-z] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Accepted: 08/15/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE Double level osteotomy (DLO) (femoral and tibial) is a technically demanding procedure for which pre-operative planning accuracy and intraoperative correction are key factors. The aim of this study was to assess the accuracy of the achieved correction using patient-specific cutting guides (PSCGs) compared to the planned correction, its ability to maintain joint line obliquity (JLO), and to evaluate clinical outcomes and level of patient satisfaction at a follow-up of two years. METHODS A single-centre, prospective observational study including 22 patients who underwent DLO by PSCGs between 2014 and 2018 was performed. Post-operative alignment was evaluated and compared with the target angular values to define the accuracy of the correction for the hip-knee-ankle angle (ΔHKA), medial proximal tibial angle (ΔMPTA), lateral distal femoral angle (ΔLDFA), and posterior proximal tibial angle (ΔPPTA). Pre- and post-operative JLO was also evaluated. At two year follow-up, changes in the KOOS sub-scores and patient satisfaction were recorded. The Mann-Whitney U test with 95% confidence interval (95% CI) was used to evaluate the differences between two variables; the paired Student's t test was used to estimate evolution of functional outcomes. RESULTS The mean ΔHKA was 1.3 ± 0.5°; the mean ΔMPTA was 0.98 ± 0.3°; the mean ΔLDFA was 0.94 ± 0.2°; ΔPPTA was 0.45 ± 0.4°. The orientation of the joint line was preserved with a mean difference in the JLO of 0.4 ± 0.2. At last follow-up, it was recorded a significant improvement in all KOOS scores, and 19 patients were enthusiastic, two satisfied, and one moderately satisfied. CONCLUSION Performing a DLO using PSCGs produces an accurate correction, without modification of the joint line orientation and with good functional outcomes at two year follow-up.
Collapse
Affiliation(s)
- Francesco Grasso
- IRCCS-Istituto Ortopedico Galeazzi, University of Milan, Milan, Italy
| | - Pierre Martz
- Service de Chirurgie Orthopédique, Centre-Hospitalo-Universitaire de Dijon, Dijon, France
| | - Grégoire Micicoi
- Institute of Movement and Locomotion, Department of Orthopedics and Traumatology, St. Marguerite Hospital, 270 Boulevard Sainte Marguerite, BP 29 13274, Marseille, France
| | - Raghbir Khakha
- Institute of Movement and Locomotion, Department of Orthopedics and Traumatology, St. Marguerite Hospital, 270 Boulevard Sainte Marguerite, BP 29 13274, Marseille, France
| | - Kristian Kley
- Institute of Movement and Locomotion, Department of Orthopedics and Traumatology, St. Marguerite Hospital, 270 Boulevard Sainte Marguerite, BP 29 13274, Marseille, France
| | - Lukas Hanak
- Institute of Movement and Locomotion, Department of Orthopedics and Traumatology, St. Marguerite Hospital, 270 Boulevard Sainte Marguerite, BP 29 13274, Marseille, France
| | - Matthieu Ollivier
- Institute of Movement and Locomotion, Department of Orthopedics and Traumatology, St. Marguerite Hospital, 270 Boulevard Sainte Marguerite, BP 29 13274, Marseille, France.
- Aix-Marseille Université, CNRS, ISM UMR 7287, 13288, Marseille Cedex 09, France.
| | - Christophe Jacquet
- Institute of Movement and Locomotion, Department of Orthopedics and Traumatology, St. Marguerite Hospital, 270 Boulevard Sainte Marguerite, BP 29 13274, Marseille, France
- Aix-Marseille Université, CNRS, ISM UMR 7287, 13288, Marseille Cedex 09, France
| |
Collapse
|