1
|
Suzuki R, Dannoura Y, Asakawa N, Makino T, Yokoshiki H. Intravascular ultrasound findings of the protrusion of the EXOSEAL plug that caused acute limb ischemia. J Vasc Surg Cases Innov Tech 2022; 9:101083. [PMID: 36747600 PMCID: PMC9898730 DOI: 10.1016/j.jvscit.2022.101083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Accepted: 11/21/2022] [Indexed: 12/24/2022] Open
Abstract
Vascular closure devices have become popular for rapid hemostasis and early ambulation. However, there are a few reports of complications. We presented a case with acute limb ischemia caused by the protrusion of the EXOSEAL plug into the vessel. Intravascular ultrasound imaging helped determine the plug that caused the occlusion.
Collapse
Affiliation(s)
- Riho Suzuki
- Correspondence: Riho Suzuki, MD, Department Cardiovascular Medicine, Sapporo City General Hospital, 13-1-1, Kita-11-jonishi, Chuo-ku, Sapporo 060-8604, Japan
| | | | | | | | | |
Collapse
|
2
|
Kennedy SA, Rajan DK, Bassett P, Tan KT, Jaberi A, Mafeld S. Complication rates associated with antegrade use of vascular closure devices: a systematic review and pooled analysis. J Vasc Surg 2021; 73:722-730.e1. [PMID: 32950629 DOI: 10.1016/j.jvs.2020.08.133] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2020] [Accepted: 08/19/2020] [Indexed: 01/25/2023]
Abstract
BACKGROUND Vascular closure devices (VCDs) have become a mainstay in endovascular interventions in recent years. On-label use only allows for retrograde interventions originating at the common femoral artery (CFA). However, off-label use in antegrade and/or superficial femoral artery (SFA) access has become more common in the treatment of peripheral arterial disease. Despite this, there is a paucity of comparative literature assessing individual VCD safety profiles and relative complication risks of CFA vs SFA applications. METHODS MEDLINE and EMBASE systematic searches were performed from inception to October 2019 to identify studies assessing VCD use in antegrade CFA and SFA interventions. Abstract selection and data extraction were performed by two independent reviewers. Primary outcomes included bleeding-related complications, vessel occlusion or stenosis, embolization, pseudoaneurysm formation, or arteriovenous fistula formation. RESULTS Twenty-four unique studies with 4124 vascular closure events via six unique VCDs were included (Angioseal, Exoseal, Femoseal, Glubran 2, Mynx, Starclose; 3698 CFA, 426 SFA). Pooled occurrence of all complications across closure devices used in the CFA and SFA ranged from 0.9% (Mynx) to 7.4% (Starclose) and 0% (Perclose) to 10.1% (Starclose), respectively, depending on VCD type. Clinically meaningful differences were identified between devices with a trend toward significance (P = .08 CFA, P = .07 SFA). Individual devices demonstrated a range of bleeding complication rates from 0.4% (Mynx) to 7.2% (Femoseal) for the CFA site and from 0% (Perclose) to 6.4% (Starclose) for the SFA site (P = .01 and P = .03, respectively). Significant heterogeneity between studies precludes definitive characterization of the device as cause for variations in bleeding complication rates. Pooled complication rates did not differ between the CFA and SFA arms (4.6% vs 5.8%, P = .56). Bleeding complication rates also did not differ between the CFA and SFA arms (3.6% vs 3.6%, P = .98). CONCLUSIONS Clinically meaningful differences in overall pooled complications were identified between VCDs with a trend toward significance. Significant differences between VCDs exist with respect to bleeding risk. However, this must be interpreted with caution as these differences could be secondary to interstudy heterogeneity. Finally, no difference was identified between antegrade SFA and CFA VCD use with respect to overall complication and bleeding risks.
Collapse
Affiliation(s)
- Sean A Kennedy
- Division of Vascular and Interventional Radiology, Joint Department of Medical Imaging, University Health Network and Mount Sinai Hospital, University of Toronto, Toronto, Ontario, Canada.
| | - Dheeraj K Rajan
- Division of Vascular and Interventional Radiology, Joint Department of Medical Imaging, University Health Network and Mount Sinai Hospital, University of Toronto, Toronto, Ontario, Canada
| | - Paul Bassett
- Statsconsultancy Ltd, Amersham, Buckinghamshire, United Kingdom
| | - Kong Teng Tan
- Division of Vascular and Interventional Radiology, Joint Department of Medical Imaging, University Health Network and Mount Sinai Hospital, University of Toronto, Toronto, Ontario, Canada
| | - Arash Jaberi
- Division of Vascular and Interventional Radiology, Joint Department of Medical Imaging, University Health Network and Mount Sinai Hospital, University of Toronto, Toronto, Ontario, Canada
| | - Sebastian Mafeld
- Division of Vascular and Interventional Radiology, Joint Department of Medical Imaging, University Health Network and Mount Sinai Hospital, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
3
|
Caymaz I, Nurili F, Kolcak O, Aras O, Gumus B. Success and reliability of extrafemoral Exoseal vascular closure device: “Off-label” usage. Interv Med Appl Sci 2020; 11:182-186. [PMID: 36343285 PMCID: PMC9467335 DOI: 10.1556/1646.11.2019.22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2017] [Revised: 10/20/2018] [Accepted: 07/07/2019] [Indexed: 12/01/2022] Open
Abstract
Aim The aim of this study is to present the reliability and efficacy of Exoseal vascular closure device (EVCD) for closure of extrafemoral punctures. Materials and methods All patients who were treated with EVCD following arterial endovascular treatment involving an extrafemoral puncture between April 2013 and January 2014 were examined retrospectively. This study included 11 patients (4 women and 7 men between the ages of 48 and 87 years; average age = 65 years). A total of 13 procedures were performed in 11 patients involving the following access routes: brachial artery (n = 5), popliteal artery (n = 4), and polytetrafluoroethylene graft (n = 4). Results Twelve out of 13 EVCD procedures achieved technical success and procedural success. One minor and one major complications occurred. Both complications were revealed to be pseudoaneurysms, both in the brachial artery. Pseudoaneurysm of the minor complication was treated by Fibrin Sealant (Tisseel) injection guided by ultrasonography and the other pseudoaneurysm was treated by covered stent placement. Conclusions The femoral artery is an essential access route of arterial endovascular procedures; however, in some cases, the extrafemoral arterial route is necessary. In this study, EVCD was found to be useful for closing extrafemoral arterial routes. This study had a limited number of cases and more large-scale studies are needed.
Collapse
Affiliation(s)
- Ismail Caymaz
- 1 Department of Interventional Radiology, Baskent Medical Faculty, Istanbul Training and Research Hospital, Istanbul, Turkey
- 2 Istanbul Medeniyet University Medical School, Goztepe Training and Research Hospital, Istanbul, Turkey
| | - Fuad Nurili
- 3 Department of Radiology, Weil Cornell Medical College, New York, NY, USA
| | - Ozlem Kolcak
- 4 Department of Interventional Radiology, Kartal Dr. Lutfi Kirdar Training and Research Hospital, Istanbul, Turkey
| | - Omer Aras
- 5 Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Burcak Gumus
- 1 Department of Interventional Radiology, Baskent Medical Faculty, Istanbul Training and Research Hospital, Istanbul, Turkey
| |
Collapse
|
4
|
Kawasaki D, Yamada T, Fukunaga M. Feasibility and Safety of the Direct Occluded Vessel Puncture Technique as a New Access Site for Complex Peripheral Artery Occlusive Disease. J Atheroscler Thromb 2020; 28:349-355. [PMID: 32565529 PMCID: PMC8147016 DOI: 10.5551/jat.57083] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Aim: This study aims to describe the feasibility and safety of direct occluded vessel puncture as a new access site for complex peripheral artery occlusive disease. Methods: Eleven consecutive patients with symptomatic peripheral artery disease underwent endovascular therapy using the direct occluded vessel puncture technique. The occluded vessel was punctured using a dedicated 20 G needle and the Hi-Torque Command 18 ST guidewire under duplex echo or fluoroscopic guidance, and a 6 Fr sheath was then inserted. Hemostasis was achieved with the Exoseal® Vascular Closure Device. Results: Direct occluded vessel puncture was achieved in 10 of 11 cases (90.9%), and procedural success was achieved in all cases. There were no in-hospital deaths or any complications, including bleeding, pseudoaneurysms, thrombosis, or surgical conversion. Conclusion: The direct occluded vessel puncture technique using a 20 G needle and the Hi-Torque Command 18 ST is feasible and safe. This technique may also be used as an alternative option when there are no appropriate approach sites.
Collapse
|
5
|
Wei X, Han T, Sun Y, Sun X, Wu Y, Wang S, Zhou J, Zhao Z, Jing Z. A Retrospective Study Comparing the Effectiveness and Safety of EXOSEAL Vascular Closure Device to Manual Compression in Patients Undergoing Percutaneous Transbrachial Procedures. Ann Vasc Surg 2019; 62:310-317. [PMID: 31449959 DOI: 10.1016/j.avsg.2019.06.031] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Revised: 06/10/2019] [Accepted: 06/16/2019] [Indexed: 12/20/2022]
Abstract
BACKGROUND This study aimed to assess the safety and efficacy of EXOSEAL vascular closure device (EVCD) insertion by comparing its performance with manual compression (MC) in achieving hemostasis at the brachial artery puncture site. METHODS A retrospective study of brachial artery access by using either MC or EVCD for achieving hemostasis from March 2016 to October 2017 was conducted. Patients with Stanford type B aortic dissection (TBAD) undergoing percutaneous transbrachial procedures were included. Time to hemostasis (TTH) was the primary efficacy end point. Seven-day incidence of major access site-related complications was the primary safety end point. TTH and major and minor complications associated with treatment of these 2 groups were also evaluated. RESULTS A total of 157 patients with TBAD undergoing percutaneous transbrachial procedures entered the analysis. Of these, 107 patients underwent EVCD insertion and 50 patients underwent MC. The baseline characteristics of the 2 groups were similar. TTH was significantly shorter for EVCD over MC (P < 0.05). The TTH ≥10 min in the MC group was 100.0% (n = 50), but in the EVCD group, it was ≤2 min, 87.9% (n = 107); 2-5 min, 7.5% (n = 107); and ≥10 min, 4.7% (n = 107). The EVCD group had several major complications, while the MC group had none. Two patients (1.9%, n = 107) required vascular repair, one patient (0.6%, n = 107) required blood transfusion, and 1 patient (0.6%, n = 107) developed upper limb numbness and weakness after EVCD deployment. Minor complication such as the occurrence of hematoma (≤5 cm) in the MC group was 4 (8.0%) but was also 4 (3.7%) in the EVCD group, showing statistically significant difference (P = 0.030). The incidence of ecchymosis was 8 (7.5%) in the EVCD group when compared with 13 (26.0%) in the MC group, which showed statistically significant difference (P = 0.001). Other major and minor complications showed no significant differences between these 2 groups. CONCLUSIONS After invasive procedures by 6F percutaneous access via the brachial artery in preprocedurally fully anticoagulated patients, TTH was significantly reduced in patients who underwent EVCD when compared with patients who underwent MC. MC is a safer and more convenient way to achieve hemostasis but has higher incidence of minor complications.
Collapse
Affiliation(s)
- Xiaolong Wei
- Department of Vascular Surgery, Changhai Hospital, Second Military Medical University, Shanghai, China
| | - Tonglei Han
- Department of Vascular Surgery, Changhai Hospital, Second Military Medical University, Shanghai, China
| | - Yudong Sun
- Department of General Surgery, Nanjing General Hospital of Eastern Theater Command, Nanjing, China
| | - Xiuli Sun
- Department of ophthalmology, Jinan Aier Eye hospital, Jinan, China
| | - Yani Wu
- Department of Breast and Thyroid Surgery, Changhai Hospital, Second Military Medical University, Shanghai, China
| | - Shiying Wang
- Department of Vascular Surgery, Changhai Hospital, Second Military Medical University, Shanghai, China
| | - Jian Zhou
- Department of Vascular Surgery, Changhai Hospital, Second Military Medical University, Shanghai, China.
| | - Zhiqing Zhao
- Department of Vascular Surgery, Changhai Hospital, Second Military Medical University, Shanghai, China.
| | - Zaiping Jing
- Department of Vascular Surgery, Changhai Hospital, Second Military Medical University, Shanghai, China.
| |
Collapse
|
6
|
Tagliaferro FB, Orgera G, Mascagni L, Laurino F, Tipaldi MA, Cariati M, Rossi M. FemoSeal ® vascular closure device for antegrade common femoral artery access: Safety and technical notes. J Vasc Access 2019; 21:79-85. [PMID: 31232151 DOI: 10.1177/1129729819854593] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
PURPOSE To retrospectively assess the efficacy and safety of FemoSeal® vascular closure device to achieve hemostasis following antegrade common femoral artery puncture after lower limb revascularization using vascular sheaths from 5 to 8 Fr. METHODS We reviewed the hemostatic outcome achieved with FemoSeal in 103 consecutive patients (mean age: 69 ± 8 years, 71 males) that undergone to 111 antegrade common femoral artery accesses for percutaneous lower limbs revascularization using 5- to 8-Fr vascular sheaths. We used FemoSeal in an unselected population, without exclusion criteria. The primary outcome was the technical success, meant as achieving complete hemostasis without immediate complications. RESULTS Hemostasis was achieved in all 111 puncture sites (100% technical success). We observed eight (7%) puncture site minor complications (hematomas), none of which affecting the patients' outcome or requiring further therapies or increasing the hospital stay. There were no statistically significant differences between the variables potentially related to the occurrence of complications (age, international normalized ratio, platelet count, partial thromboplastin time ratio, body mass index, and common femoral arteries calcification grade) in patients with and without complications. Complications group mean body mass index was 26.4 ± 2.8 kg/m2 versus non-complications group 26.6 ± 4.4 kg/m2, p = 0.92. Mean international normalized ratio and partial thromboplastin time ratio were 1.05 ± 0.01 and 1.05 ± 0.14 versus 1.13 ± 0.2 (p = 0.39) and 1.12 ± 0.23 (p = 0.53), respectively. Common femoral arteries calcification grade was the same (mean: 1, p = 1). Platelet count was 202 × 103/mL ± 66.7 versus 226 × 103/mL ± 91.2, p = 0.55. Mean age was 72.3 ± 10 years versus 72.8 ± 8 years, p = 0.86. CONCLUSION The low rate (7%) and grading of the adverse events, combined with the high technical success rate (100%), in an unselected group of patients treated in daily routine, suggest high safety and efficacy of FemoSeal vascular closure device in antegrade common femoral artery puncture site hemostasis when using vascular sheaths ranging from 5 to 8 Fr. Therefore, FemoSeal could be considered as a first-line hemostasis strategy in such cases.
Collapse
Affiliation(s)
| | - Gianluigi Orgera
- Unit of Interventional Radiology, Sant'Andrea University Hospital, La Sapienza University, Rome, Italy
| | - Luca Mascagni
- Unit of Interventional Radiology, Sant'Andrea University Hospital, La Sapienza University, Rome, Italy
| | - Florindo Laurino
- Unit of Interventional Radiology, Sant'Andrea University Hospital, La Sapienza University, Rome, Italy
| | - Marcello Andrea Tipaldi
- Unit of Interventional Radiology, Sant'Andrea University Hospital, La Sapienza University, Rome, Italy
| | - Maurizio Cariati
- Advanced Diagnostic-Therapeutic Technologies Department, ASST Santi Paolo e Carlo, Milano, Italy
| | - Michele Rossi
- Unit of Interventional Radiology, Sant'Andrea University Hospital, La Sapienza University, Rome, Italy
| |
Collapse
|
7
|
Han Y, Kwon JH, Park S. Korean single-center experience with femoral access closure using the ExoSeal device. World J Radiol 2018; 10:108-115. [PMID: 30310545 PMCID: PMC6177558 DOI: 10.4329/wjr.v10.i9.108] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2018] [Revised: 08/06/2018] [Accepted: 08/24/2018] [Indexed: 02/06/2023] Open
Abstract
AIM To report 17-mo experience of femoral artery puncture site closure during angiographic procedures using ExoSeal vascular closure devices (VCDs).
METHODS Between November 2015 and April 2017, we performed 179 diagnostic and interventional angiographic procedures via a common femoral arterial access. The ExoSeal VCD was used at the puncture site to achieve hemostasis in 125 patients. We evaluated the technical and procedural success rates, the complications, and the factors affecting the hemostasis time of the ExoSeal VCDs.
RESULTS Technical and procedural successes were achieved in 176 cases (98.0%) and 128 cases (71.5%), respectively. Device failure occurred in 3 (1.7%) cases. In 1 case (0.6%) a small hematoma developed, but there were no major complications. Among the hemostasis-relevant variables, a history of drinking alcohol, low platelet (PLT) count, and high prothrombin time-international normalized ratio (commonly known as PT-INR) values were the statistically significant predictors of the need for longer manual compression (MC). There was no difference in the success rates between the repeat and single ExoSeal procedure groups, and repeated use of the ExoSeal did not affect hemostasis time.
CONCLUSION The ExoSeal VCD effectively achieves hemostasis, with few complications. Longer light MC may be needed with alcohol drinkers, low PLT count, and high PT-INR values.
Collapse
Affiliation(s)
- Yoonhee Han
- Department of Radiology, Dongguk University Ilsan Hospital, Goyang-si 10326, Gyeonggi-do, South Korea
| | - Jae Hyun Kwon
- Department of Radiology, Dongguk University Ilsan Hospital, Goyang-si 10326, Gyeonggi-do, South Korea
| | - Surin Park
- Department of Radiology, Dongguk University Ilsan Hospital, Goyang-si 10326, Gyeonggi-do, South Korea
| |
Collapse
|
8
|
Ballı Ö, Çakır V, Coşkun M, Pekçevik R, Gür S. Implementation of the EXOSEAL Vascular Closure Device in the Transpopliteal Arterial Approach. J Vasc Interv Radiol 2018; 29:1180-1186. [DOI: 10.1016/j.jvir.2018.03.023] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2017] [Revised: 02/15/2018] [Accepted: 03/22/2018] [Indexed: 01/18/2023] Open
|
9
|
Spiliopoulos S, Kitrou P, Christeas N, Karnabatidis D. Starclose SE® hemostasis after 6F direct antegrade superficial femoral artery access distal to the femoral head for peripheral endovascular procedures in obese patients. Diagn Interv Radiol 2016; 22:542-547. [PMID: 27641942 PMCID: PMC5098949 DOI: 10.5152/dir.2016.15614] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2015] [Revised: 02/18/2016] [Accepted: 03/17/2016] [Indexed: 02/05/2023]
Abstract
PURPOSE Direct superficial femoral artery (SFA) antegrade puncture is a valid alternative to common femoral artery (CFA) access for peripheral vascular interventions. Data investigating vascular closure device (VCD) hemostasis of distant SFA 6F access are limited. We aimed to investigate the safety and effectiveness of the Starclose SE® VCD for hemostasis, following direct 6F antegrade SFA access distal to the femoral head. METHODS This prospective, single-center study included patients who were not suitable for CFA puncture and were scheduled to undergo peripheral endovascular interventions using direct antegrade SFA 6F access, at least 2 cm below the inferior edge of femoral head. Hemostasis was obtained with the Starclose SE® VCD (Abbott Laboratories). Primary endpoints were successful hemostasis rate and periprocedural (30-day) major complication rate. Secondary endpoint was the rate of minor complications. Clinical and Doppler ultrasound follow-up was performed at discharge and at one month. RESULTS Between September 2014 and August 2015, a total of 30 patients (21 male; 70.0%) with a mean body mass index of 41.2 kg/m2 were enrolled. Mean age was 72±9 years (range, 67-88 years). Most patients suffered from critical limb ischemia (87.1%) and diabetes (61.3%). Calcifications were present in eight cases (26.6%). Reason for direct SFA puncture was obesity (100%). Successful hemostasis was achieved in 100% of the cases. No major complications were noted after one-month follow-up. Minor complications included two <5 cm hematomas (6.6%) not necessitating treatment. CONCLUSION In this prospective study, Starclose SE® VCD was safe and effective for hemostasis of antegrade direct SFA puncture. Uncomplicated hemostasis was achieved even in cases of puncturing 2 to 7 cm below the inferior edge of the femoral head.
Collapse
Affiliation(s)
- Stavros Spiliopoulos
- From the Department of Interventional Radiology (S.S ), Patras University Hospital, Rio, Greece
| | - Panagiotis Kitrou
- From the Department of Interventional Radiology (S.S ), Patras University Hospital, Rio, Greece
| | - Nikolaos Christeas
- From the Department of Interventional Radiology (S.S ), Patras University Hospital, Rio, Greece
| | - Dimitris Karnabatidis
- From the Department of Interventional Radiology (S.S ), Patras University Hospital, Rio, Greece
| |
Collapse
|
10
|
Patient Satisfaction After Femoral Arterial Access Site Closure Using the ExoSeal® Vascular Closure Device Compared to Manual Compression: A Prospective Intra-individual Comparative Study. Cardiovasc Intervent Radiol 2015; 39:21-7. [DOI: 10.1007/s00270-015-1204-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2015] [Accepted: 08/16/2015] [Indexed: 01/13/2023]
|