1
|
Foti G, Ascenti G, Agostini A, Longo C, Lombardo F, Inno A, Modena A, Gori S. Dual-Energy CT in Oncologic Imaging. Tomography 2024; 10:299-319. [PMID: 38535766 PMCID: PMC10975567 DOI: 10.3390/tomography10030024] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Revised: 02/13/2024] [Accepted: 02/22/2024] [Indexed: 08/25/2024] Open
Abstract
Dual-energy CT (DECT) is an innovative technology that is increasingly widespread in clinical practice. DECT allows for tissue characterization beyond that of conventional CT as imaging is performed using different energy spectra that can help differentiate tissues based on their specific attenuation properties at different X-ray energies. The most employed post-processing applications of DECT include virtual monoenergetic images (VMIs), iodine density maps, virtual non-contrast images (VNC), and virtual non-calcium (VNCa) for bone marrow edema (BME) detection. The diverse array of images obtained through DECT acquisitions offers numerous benefits, including enhanced lesion detection and characterization, precise determination of material composition, decreased iodine dose, and reduced artifacts. These versatile applications play an increasingly significant role in tumor assessment and oncologic imaging, encompassing the diagnosis of primary tumors, local and metastatic staging, post-therapy evaluation, and complication management. This article provides a comprehensive review of the principal applications and post-processing techniques of DECT, with a specific focus on its utility in managing oncologic patients.
Collapse
Affiliation(s)
- Giovanni Foti
- Department of Radiology, IRCCS Ospedale Sacro Cuore Don Calabria, Via Don A. Sempreboni 5, 37024 Negrar, Italy; (C.L.); (F.L.)
| | - Giorgio Ascenti
- Department of Biomedical Sciences and Morphological and Functional Imaging, University Hospital Messina, 98122 Messina, Italy;
| | - Andrea Agostini
- Department of Clinical Special and Dental Sciences, University Politecnica delle Marche, 60126 Ancona, Italy
| | - Chiara Longo
- Department of Radiology, IRCCS Ospedale Sacro Cuore Don Calabria, Via Don A. Sempreboni 5, 37024 Negrar, Italy; (C.L.); (F.L.)
| | - Fabio Lombardo
- Department of Radiology, IRCCS Ospedale Sacro Cuore Don Calabria, Via Don A. Sempreboni 5, 37024 Negrar, Italy; (C.L.); (F.L.)
| | - Alessandro Inno
- Department of Oncology, IRCCS Ospedale Sacro Cuore Don Calabria, Via Don A. Sempreboni 5, 37024 Negrar, Italy; (A.I.); (A.M.); (S.G.)
| | - Alessandra Modena
- Department of Oncology, IRCCS Ospedale Sacro Cuore Don Calabria, Via Don A. Sempreboni 5, 37024 Negrar, Italy; (A.I.); (A.M.); (S.G.)
| | - Stefania Gori
- Department of Oncology, IRCCS Ospedale Sacro Cuore Don Calabria, Via Don A. Sempreboni 5, 37024 Negrar, Italy; (A.I.); (A.M.); (S.G.)
| |
Collapse
|
2
|
Rajiah PS, Kambadakone A, Ananthakrishnan L, Sutphin P, Kalva SP. Vascular Applications of Dual-Energy Computed Tomography. Radiol Clin North Am 2023; 61:1011-1029. [PMID: 37758354 DOI: 10.1016/j.rcl.2023.05.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/03/2023]
Abstract
Dual- or multi-energy CT imaging provides several advantages over conventional CT in the context of vascular imaging. Specific advantages include the use of low-energy virtual monoenergetic images (VMIs) to boost iodine attenuation to salvage suboptimal enhanced studies, perform low-contrast material dose studies, and increase conspicuity of small vessels and lesions. Alternatively, high-energy VMIs reduce artifacts caused by some metals, endoprosthesis, calcium blooming, and beam hardening. Virtual non-contrast (VNC) images reduce radiation dose by eliminating the need for a true non-contrast acquisition in multiphasic CT studies. Iodine maps can be used to evaluate perfusion of tissues and lesions.
Collapse
Affiliation(s)
- Prabhakar S Rajiah
- Department of Radiology, Mayo Clinic, 200 1st Street Southwest, Rochester, MN 55905, USA.
| | | | | | - Patrick Sutphin
- Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
| | - Sanjeeva P Kalva
- Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
| |
Collapse
|
3
|
Dual-Layer Spectral CT of Pancreas Ductal Adenocarcinoma: Can Virtual Monoenergetic Images of the Portal Venous Phase Be an Alternative to the Pancreatic-Phase Scan? J Belg Soc Radiol 2022; 106:83. [PMID: 36213373 PMCID: PMC9504095 DOI: 10.5334/jbsr.2798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Accepted: 08/27/2022] [Indexed: 12/02/2022] Open
Abstract
Objectives: To determine the performance of virtual monoenergetic images (VMIs) of the portal venous phase (PVP) compared with the pancreatic-phase image for pancreatic ductal adenocarcinoma (PDAC) evaluation. Materials and methods: This retrospective study enrolled 64 patients with PDAC who underwent pancreatic CT with dual-layer spectral CT between February 2018 and January 2020. A polychromatic pancreatic-phase image and VMIs at 40 (VMI40), 55 (VMI55), and 70 keV (VMI70) of the PVP were generated. The tumor-to-pancreas contrast-to-noise ratio (CNR), attenuation difference, peripancreatic vascular signal-to-noise ratio (SNR), and CNR were compared among the four images. Subjective image analysis was performed for tumor conspicuity, heterogeneity, size, and arterial invasion. Results: VMI40 and VMI55 demonstrated higher tumor-to-pancreas CNR, attenuation difference, and higher peripancreatic vascular CNR and SNR than the pancreatic-phase image and VMI70 (p < .001). On subjective analysis, VMI55 showed the best tumor conspicuity. Moreover, the inter-reader agreement for arterial invasion in VMIs from the PVP was not inferior to that in the pancreatic-phase image. Conclusion: For evaluating PDAC, the VMI55 of the PVP was superior to the pancreatic-phase image in terms of tumor conspicuity and peripancreatic vascular enhancement. Therefore, the VMI55 of the PVP could be an alternative to the pancreatic-phase scan in patients suspicious of PDAC.
Collapse
|
4
|
Fernández-Pérez GC, Fraga Piñeiro C, Oñate Miranda M, Díez Blanco M, Mato Chaín J, Collazos Martínez MA. Dual-energy CT: Technical considerations and clinical applications. RADIOLOGIA 2022; 64:445-455. [PMID: 36243444 DOI: 10.1016/j.rxeng.2022.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Accepted: 06/20/2022] [Indexed: 06/16/2023]
Abstract
Although dual-energy CT was initially described by Hounsfield in 1973, it remains underused in clinical practice. It is therefore important to emphasize the clinical benefits and limitations of this technique. Iodine mapping makes it possible to quantify the uptake of iodine, which is very important in characterizing tumors, lung perfusion, pulmonary nodules, and the tumor response to new treatments. Dual-energy CT also makes it possible to obtain virtual single-energy images and virtual images without iodinated contrast or without calcium, as well as to separate materials such as uric acid or fat and to elaborate hepatic iron overload maps. In this article, we review some of the clinical benefits and technical limitations to improve understanding of dual-energy CT and expand its use in clinical practice.
Collapse
Affiliation(s)
- G C Fernández-Pérez
- Servicio de Radiodiagnóstico, Hospital Universitario Río Hortega, Grupo Recoletas, Valladolid, Spain.
| | - C Fraga Piñeiro
- Técnico Aplicaciones Siemens Healthineers, General Electric Company, Spain
| | - M Oñate Miranda
- Servicio de Radiodiagnóstico, Hospital Universitario Río Hortega, Valladolid, Spain
| | - M Díez Blanco
- Servicio de Radiodiagnóstico, Hospital Universitario Río Hortega, Valladolid, Spain
| | - J Mato Chaín
- Servicio de Radiodiagnóstico, Hospital Universitario Río Hortega, Valladolid, Spain
| | | |
Collapse
|
5
|
Fernández-Pérez G, Fraga Piñeiro C, Oñate Miranda M, Díez Blanco M, Mato Chaín J, Collazos Martínez M. Energía Dual en TC. Consideraciones técnicas y aplicaciones clínicas. RADIOLOGIA 2022. [DOI: 10.1016/j.rx.2022.06.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
6
|
Lennartz S, Laukamp KR, Tandon Y, Jordan M, Große Hokamp N, Zopfs D, Pennig L, Obmann M, Gilkeson RC, Herrmann KA, Ramaiya N, Gupta A. Abdominal vessel depiction on virtual triphasic spectral detector CT: initial clinical experience. Abdom Radiol (NY) 2021; 46:3501-3511. [PMID: 33715050 PMCID: PMC8215039 DOI: 10.1007/s00261-021-03001-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Revised: 02/10/2021] [Accepted: 02/13/2021] [Indexed: 12/19/2022]
Abstract
Purpose To evaluate vessel assessment in virtual monoenergetic images (VMI40keV) and virtual-non-contrast images (VNC) derived from venous phase spectral detector computed tomography (SDCT) acquisitions in comparison to arterial phase and true non-contrast (TNC) images. Methods Triphasic abdominal SDCT was performed in 25 patients including TNC, arterial and venous phase. VMI40keV and VNC were reconstructed from the venous phase and compared to conventional arterial-phase images (CIart), TNC and conventional venous-phase images (CIven). Vessel contrast and virtual contrast removal were analyzed with region-of-interest-based measurements and in a qualitative assessment. Results Quantitative analysis revealed no significant attenuation differences between TNC and VNC in arterial vessels (p-range 0.07–0.47) except for the renal artery (p = 0.011). For venous vessels, significant differences between TNC and VNC were found for all veins (p < 0.001) except the inferior vena cava (p = 0.26), yet these differences remained within a 10 HU range in most patients. No significant attenuation differences were found between CIart/VMI40keV in arterial vessels (p-range 0.06–0.86). Contrast-to-noise ratio provided by VMI40keV and CIart was equivalent for all arterial vessels assessed (p-range 0.14–0.91). Qualitatively, VMI40keV showed similar enhancement of abdominal and pelvic arteries as CIart and VNC were rated comparable to TNC. Conclusion Our study suggests that VNC and VMI40keV derived from single venous-phase SDCT offer comparable assessment of major abdominal vessels as provided by routine triphasic examinations, if no dynamic contrast information is required.
Collapse
Affiliation(s)
- Simon Lennartz
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University Cologne, Kerpener Straße, 62, 50937, Cologne, Germany
- Else Kröner Forschungskolleg Clonal Evolution in Cancer, University Hospital Cologne, Weyertal 115b, 50931, Cologne, Germany
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114, USA
| | - Kai Roman Laukamp
- Department of Radiology, University Hospitals Cleveland Medical Center, 11000 Euclid Ave, Cleveland, OH, 44106, USA.
- Department of Radiology, Case Western Reserve University, Cleveland, OH, USA.
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University Cologne, Kerpener Straße, 62, 50937, Cologne, Germany.
| | - Yasmeen Tandon
- Department of Radiology, Case Western Reserve University, Cleveland, OH, USA
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University Cologne, Kerpener Straße, 62, 50937, Cologne, Germany
- Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN, 55905, USA
| | - Michelle Jordan
- Department of Radiology, University Hospitals Cleveland Medical Center, 11000 Euclid Ave, Cleveland, OH, 44106, USA
- Department of Radiology, Case Western Reserve University, Cleveland, OH, USA
| | - Nils Große Hokamp
- Department of Radiology, University Hospitals Cleveland Medical Center, 11000 Euclid Ave, Cleveland, OH, 44106, USA
- Department of Radiology, Case Western Reserve University, Cleveland, OH, USA
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University Cologne, Kerpener Straße, 62, 50937, Cologne, Germany
| | - David Zopfs
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University Cologne, Kerpener Straße, 62, 50937, Cologne, Germany
| | - Lenhard Pennig
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University Cologne, Kerpener Straße, 62, 50937, Cologne, Germany
| | - Markus Obmann
- Department of Radiology and Nuclear Medicine, University Hospital Basel, Basel, Switzerland
| | - Robert C Gilkeson
- Department of Radiology, University Hospitals Cleveland Medical Center, 11000 Euclid Ave, Cleveland, OH, 44106, USA
- Department of Radiology, Case Western Reserve University, Cleveland, OH, USA
| | - Karin A Herrmann
- Department of Radiology, Case Western Reserve University, Cleveland, OH, USA
| | - Nikhil Ramaiya
- Department of Radiology, University Hospitals Cleveland Medical Center, 11000 Euclid Ave, Cleveland, OH, 44106, USA
- Department of Radiology, Case Western Reserve University, Cleveland, OH, USA
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114, USA
| | - Amit Gupta
- Department of Radiology, University Hospitals Cleveland Medical Center, 11000 Euclid Ave, Cleveland, OH, 44106, USA
- Department of Radiology, Case Western Reserve University, Cleveland, OH, USA
| |
Collapse
|
7
|
Foti G, Silva R, Faccioli N, Fighera A, Menghini R, Campagnola A, Carbognin G. Identification of pulmonary embolism: diagnostic accuracy of venous-phase dual-energy CT in comparison to pulmonary arteries CT angiography. Eur Radiol 2020; 31:1923-1931. [PMID: 32965572 DOI: 10.1007/s00330-020-07286-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 07/27/2020] [Accepted: 09/11/2020] [Indexed: 11/30/2022]
Abstract
OBJECTIVES To evaluate the diagnostic accuracy of venous-phase dual-energy computed tomography (VP-DECT) in the identification of PE compared with standard CT pulmonary angiography (CTPA). METHODS This prospective IRB-approved study included 61 consecutive oncology patients (35 females, 26 males, mean age 66.91 years) examined by CTPA and VP-DECT. DECT data were post-processed on a SyngoVia workstation to obtain monoenergetic images (MEI+). The diagnosis of PE was based on the presence of any vascular perfusion defects. DECT images were evaluated independently by two radiologists (8 and 16 years of experience). A consensus reading of CTPA images (two senior radiologists, 18 and 24 years of experience) represented the reference for diagnosis. The diagnostic accuracy values of VP-DECT on a per-patient and per-lobe basis were assessed. Interobserver agreement was calculated using k-statistics. A value of p < 0.05 was considered statistically significant. RESULTS Thirty of 61 patients (49.18%) were diagnosed with PE by CTPA, with 57/366 lobes being involved (15.57%). The sensitivity and specificity of the per-patient analysis of VP-DECT images were 90.0% (27/30) and 100% (31/31) respectively, for both readers. As concerns the per-lobe analysis, the sensitivity ranged from 100% for the right lower lobe to 50% for the left upper lobe for reader 1, and from 100% for the left upper lobe to 69.23% for the lingula for reader 2. The interobserver agreement ranged from 0.8671 (patients' analysis) to 0.6419 (lobes' analysis). CONCLUSION VP-DECT could be considered an accurate imaging tool for diagnosing PE in a selected, high-prevalence population, compared with CTPA. KEY POINTS • With regard to the patients' analysis, venous-phase DECT sensitivity and specificity in diagnosing pulmonary embolism were 90% and 100%, respectively, for both readers. • With regard to the lobes' analysis, the sensitivity ranged from 100 to 50%, for reader 1, and from 100 to 69.23%, for reader 2, respectively. • The sensitivity and specificity of lung perfusion maps obtained from venous DECT were 73.33% and 67.74% as concerns the patients' analysis and 71.92% and 75.72% as regards the lobes' analysis, respectively.
Collapse
Affiliation(s)
- Giovanni Foti
- Department of Radiology, IRCCS Sacro Cuore Don Calabria Hospital, Via Don A. Sempreboni 1, 37024, Negrar, VR, Italy.
| | - Ronaldo Silva
- Clinical Research Unit, IRCCS Sacro Cuore Don Calabria Hospital, Negrar, Italy
| | - Niccolò Faccioli
- Department of Radiology, Verona University Hospital, Verona, Italy
| | | | | | | | - Giovanni Carbognin
- Department of Radiology, IRCCS Sacro Cuore Don Calabria Hospital, Via Don A. Sempreboni 1, 37024, Negrar, VR, Italy
| |
Collapse
|
8
|
Rajiah P, Parakh A, Kay F, Baruah D, Kambadakone AR, Leng S. Update on Multienergy CT: Physics, Principles, and Applications. Radiographics 2020; 40:1284-1308. [DOI: 10.1148/rg.2020200038] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Prabhakar Rajiah
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.R., S.L.); Department of Radiology, Massachusetts General Hospital, Boston, Mass (A.P., A.R.K.); Department of Radiology, UT Southwestern Medical Center, Dallas, Tex (F.K.); and Department of Radiology, Medical University of South Carolina, Charleston, SC (D.B.)
| | - Anushri Parakh
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.R., S.L.); Department of Radiology, Massachusetts General Hospital, Boston, Mass (A.P., A.R.K.); Department of Radiology, UT Southwestern Medical Center, Dallas, Tex (F.K.); and Department of Radiology, Medical University of South Carolina, Charleston, SC (D.B.)
| | - Fernando Kay
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.R., S.L.); Department of Radiology, Massachusetts General Hospital, Boston, Mass (A.P., A.R.K.); Department of Radiology, UT Southwestern Medical Center, Dallas, Tex (F.K.); and Department of Radiology, Medical University of South Carolina, Charleston, SC (D.B.)
| | - Dhiraj Baruah
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.R., S.L.); Department of Radiology, Massachusetts General Hospital, Boston, Mass (A.P., A.R.K.); Department of Radiology, UT Southwestern Medical Center, Dallas, Tex (F.K.); and Department of Radiology, Medical University of South Carolina, Charleston, SC (D.B.)
| | - Avinash R. Kambadakone
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.R., S.L.); Department of Radiology, Massachusetts General Hospital, Boston, Mass (A.P., A.R.K.); Department of Radiology, UT Southwestern Medical Center, Dallas, Tex (F.K.); and Department of Radiology, Medical University of South Carolina, Charleston, SC (D.B.)
| | - Shuai Leng
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.R., S.L.); Department of Radiology, Massachusetts General Hospital, Boston, Mass (A.P., A.R.K.); Department of Radiology, UT Southwestern Medical Center, Dallas, Tex (F.K.); and Department of Radiology, Medical University of South Carolina, Charleston, SC (D.B.)
| |
Collapse
|
9
|
Al-Baldawi Y, Große Hokamp N, Haneder S, Steinhauser S, Püsken M, Persigehl T, Maintz D, Wybranski C. Virtual mono-energetic images and iterative image reconstruction: abdominal vessel imaging in the era of spectral detector CT. Clin Radiol 2020; 75:641.e9-641.e18. [PMID: 32362502 DOI: 10.1016/j.crad.2020.03.036] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Accepted: 03/27/2020] [Indexed: 12/29/2022]
Abstract
AIM To compare the quality of virtual mono-energetic (VMI) and polychromatic images reconstructed with hybrid iterative (PCIHIR) or model-based reconstruction (PCIMBR) derived from dual-layer spectral detector computed tomography (SDCT) in arterial phase images to visualise the aorta and abdominal main branches. MATERIAL AND METHODS A retrospective review of 50 patients with abdominal arterial phase scans was undertaken. Attenuation, intraluminal noise, and signal-/contrast-to-noise ratio (S-/CNR) were assessed in the PCIHIR, PCIMBR and VMI40keV, VMI70keV, and VMI100keV images. Contrast, noise, and visualization of soft-plaque, and macro-/micro-calcifications were scored in a blinded reading by two radiologists. RESULTS VMI40keV yielded highest S-/CNR (p≤0.001). VMI70keV and PCIMBR showed comparable SNR (p≥0.999) and yielded higher SNR than PCIHIR. VMI70keV yielded higher CNR than PCIHIR (p<0.001) and PCIMBR (p<0.045). VMI100keV yielded lowest CNR (p≤0.001) and SNR (p≥0.104). In the subjective analysis, VMI40keV outperformed PCIMBR for contrast and noise, PCIMBR scored better than VMI70keV, and the latter scored better than PCIHIR for these categories (all p<0.001). PCIMBR was superior for depiction of soft-plaque and micro-calcifications (p<0.001). VMI100keV visualized micro-calcifications second best (p<0.001) and matched PCIMBR for the depiction of macro-calcifications (p>0.999), while VMI40keV scored second best for depiction of soft-plaque (p<0.020). CONCLUSIONS VMI40keV and VMI70keV yield better S-/CNR than PCIHIR and PCIMBR; however, PCIMBR visualized arteriosclerotic plaques best, followed by VMI40keV for depiction of soft-plaque and VMI100keV for macro- and micro-calcification. Based on the present findings, PCIMBR on conventional CT and VMI40keV supplemented by VMI100keV on SDCT are recommended for the diagnostic assessment of abdominal arteries.
Collapse
Affiliation(s)
- Y Al-Baldawi
- University of Cologne, Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, Cologne, Germany.
| | - N Große Hokamp
- University of Cologne, Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, Cologne, Germany
| | - S Haneder
- University of Cologne, Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, Cologne, Germany
| | - S Steinhauser
- University of Cologne, Faculty of Medicine and University Hospital Cologne, Institute for Medical Statistics and Computational Biology, Cologne, Germany
| | - M Püsken
- University of Cologne, Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, Cologne, Germany
| | - T Persigehl
- University of Cologne, Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, Cologne, Germany
| | - D Maintz
- University of Cologne, Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, Cologne, Germany
| | - C Wybranski
- University of Cologne, Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, Cologne, Germany
| |
Collapse
|
10
|
|
11
|
Aortic CT angiography using the double region of interest timing bolus technique: feasibility of 80 kVp scanning in lean patients. Int J Cardiovasc Imaging 2019; 35:2113-2121. [DOI: 10.1007/s10554-019-01660-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Accepted: 06/26/2019] [Indexed: 12/27/2022]
|