1
|
Seidel A, Leira Y, Batalla P, Caneiro L, Wichmann M, Blanco J. Three-dimensional imaging analysis of CAD/CAM custom-milled versus prefabricated allogeneic block remodelling at 6 months and long-term follow-up of dental implants: A retrospective cohort study. J Clin Periodontol 2024; 51:1005-1016. [PMID: 38710641 DOI: 10.1111/jcpe.13995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 04/17/2024] [Accepted: 04/20/2024] [Indexed: 05/08/2024]
Abstract
AIM This retrospective cohort study aimed to volumetrically investigate the bone stability rate of prefabricated allogeneic bone blocks (PBB) and computer-aided design (CAD)/computer-aided manufacturing (CAM) custom-milled allogeneic bone blocks (CCBB) for ridge augmentation. MATERIALS AND METHODS Nineteen patients were treated with 20 allografts: 11 CCBB, 9 PBB; 10 in the maxilla and 10 in the mandible. Clinical treatment history and cone beam computed tomography scans before surgery (t0), directly after graft surgery (t1) and after 6 months of healing prior to implant insertion (t2) were evaluated using a three-dimensional evaluation software for absolute bone volume, stability as well as vertical and horizontal bone gain. Furthermore, the inserted implants were analysed for survival, marginal bone loss (MBL) and complications for a mean follow-up period of 43.75 (±33.94) months. RESULTS A mean absolute volume of 2228.1 mm3 (±1205) was grafted at t1. The bone stability rate was 87.6% (±9.9) for CCBB and 83.0% (±14.5) for PBB. The stability was higher in the maxilla (91.6%) than in the mandible (79.53%). Surgery time of PBB was longer than for CCBB (mean Δ = 52 min). The survival rate of the inserted implants was 100% with a mean MBL of 0.41 mm (±0.37). CONCLUSION The clinical performance of both allograft block designs was equally satisfactory for vertical and horizontal bone grafting prior to implant placement. CLINICAL TRIAL REGISTRATION ClinicalTrials.gov: NCT06027710.
Collapse
Affiliation(s)
- Anna Seidel
- Department of Prosthodontics, University Hospital Erlangen of Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany
| | - Yago Leira
- Department of Periodontology and Oral Surgery, Faculty of Odontology, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Pilar Batalla
- Department of Periodontology and Oral Surgery, Faculty of Odontology, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Leticia Caneiro
- Department of Periodontology and Oral Surgery, Faculty of Odontology, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Manfred Wichmann
- Department of Prosthodontics, University Hospital Erlangen of Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany
| | - Juan Blanco
- Department of Periodontology and Oral Surgery, Faculty of Odontology, University of Santiago de Compostela, Santiago de Compostela, Spain
| |
Collapse
|
2
|
Seidel A, Schmitt C, Matta RE, Buchbender M, Wichmann M, Berger L. Investigation of the palatal soft tissue volume: a 3D virtual analysis for digital workflows and presurgical planning. BMC Oral Health 2022; 22:361. [PMID: 35999531 PMCID: PMC9400256 DOI: 10.1186/s12903-022-02391-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 08/11/2022] [Indexed: 12/04/2022] Open
Abstract
Background In mucogingival and implant surgery, an autologous soft tissue graft from the palate is the gold standard for reconstructing missing keratinised soft tissue and volume. Previously, presurgical measurements of the graft harvesting site were described with two-dimensional (2D) linear measurements. The present observational clinical study aimed to evaluate a three-dimensional (3D) measurement method for determining the present palatal soft tissue volume for each patient individually. Methods Pre-existing cone beam computed tomography (CBCT) scans of 20 patients were converted into 3D Standard Tessellation Language models of the bone surface. Intraoral impressions of the maxilla were taken and digitised to visualise the gingival surface. The resulting virtual models of bone (reference value) and gingival (actual value) surfaces were merged, with tooth surfaces used for registration. The region between the central incisors and the hard palate was subdivided into 5 regions of interest (ROIs). The distance between palatal bone and gingival surface was analysed both volumetrically and linearly, and the results were statistically evaluated for the ROIs.
Results The average gingival surface area on the palate was 19.1 cm2, and the mean volume was 58.2 cm3 (± 16.89). Among the ROIs, the mean linear value was highest in the most distal region, from the second molar to the hard palate (4.0 ± 1.09 mm) and lowest in the canine region (1.9 ± 0.63 mm). For mean distance, significant differences were found for the anterior palate and the most posterior palate in comparison with all other ROIs (p < 0.01). The volume measurements also declined significantly and steadily between the posterior (1.9 ± 1.0 cm3) and anterior palates (0.4 ± 0.2 cm3). Conclusions By merging digital data, palatal soft tissue could be quantified virtually. The results were reliable and comparable to previous findings with linear measurement methods. This 3D soft tissue volume analysis method fully exploited the diagnostic potential of data that are frequently collected for presurgical planning in oral surgery (i.e., CBCT + surface scans). This evaluation method might be useful for volumetric and linear measurements in other applications in anatomy and for determining palatal soft tissue dimensions in the planning stage before surgical interventions. Trial registration This observational clinical trial was retrospectively registered in the German Clinical Trials Register, reference number: DRKS00023918.
Collapse
Affiliation(s)
- Anna Seidel
- Department of Prosthodontics, University Hospital Erlangen of Friedrich-Alexander University Erlangen-Nürnberg (FAU), Glueckstrasse 11, 91054, Erlangen, Germany.
| | - Christian Schmitt
- Department of Oral and Maxillofacial Surgery, University Hospital Erlangen of Friedrich-Alexander University Erlangen-Nürnberg (FAU), Glueckstrasse 11, 91054, Erlangen, Germany
| | - Ragai Edward Matta
- Department of Prosthodontics, University Hospital Erlangen of Friedrich-Alexander University Erlangen-Nürnberg (FAU), Glueckstrasse 11, 91054, Erlangen, Germany
| | - Mayte Buchbender
- Department of Oral and Maxillofacial Surgery, University Hospital Erlangen of Friedrich-Alexander University Erlangen-Nürnberg (FAU), Glueckstrasse 11, 91054, Erlangen, Germany
| | - Manfred Wichmann
- Department of Prosthodontics, University Hospital Erlangen of Friedrich-Alexander University Erlangen-Nürnberg (FAU), Glueckstrasse 11, 91054, Erlangen, Germany
| | - Lara Berger
- Department of Prosthodontics, University Hospital Erlangen of Friedrich-Alexander University Erlangen-Nürnberg (FAU), Glueckstrasse 11, 91054, Erlangen, Germany
| |
Collapse
|
3
|
Grunz JP, Weng AM, Kunz AS, Veyhl-Wichmann M, Schmitt R, Gietzen CH, Pennig L, Herz S, Ergün S, Bley TA, Gassenmaier T. 3D cone-beam CT with a twin robotic x-ray system in elbow imaging: comparison of image quality to high-resolution multidetector CT. Eur Radiol Exp 2020; 4:52. [PMID: 32895778 PMCID: PMC7477066 DOI: 10.1186/s41747-020-00177-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Accepted: 07/03/2020] [Indexed: 02/07/2023] Open
Abstract
Background Elbow imaging is challenging with conventional multidetector computed tomography (MDCT), while cone-beam CT (CBCT) provides superior options. We compared intra-individually CBCT versus MDCT image quality in cadaveric elbows. Methods A twin robotic x-ray system with new CBCT mode and a high-resolution clinical MDCT were compared in 16 cadaveric elbows. Both systems were operated with a dedicated low-dose (LD) protocol (equivalent volume CT dose index [CTDIvol(16 cm)] = 3.3 mGy) and a regular clinical scan dose (RD) protocol (CTDIvol(16 cm) = 13.8 mGy). Image quality was evaluated by two radiologists (R1 and R2) on a seven-point Likert scale, and estimation of signal intensity in cancellous bone was conducted. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) statistics were used. Results The CBCT prototype provided superior subjective image quality compared to MDCT scans (for RD, p ≤ 0.004; for LD, p ≤ 0.001). Image quality was rated very good or excellent in 100% of the cases by both readers for RD CBCT, 100% (R1) and 93.8% (R2) for LD CBCT, 62.6% and 43.8% for RD MDCT, and 0.0% and 0.0% for LD MDCT. Single-measure ICC was 0.95 (95% confidence interval 0.91–0.97; p < 0.001). Software-based assessment supported subjective findings with less “undecided” pixels in CBCT than dose-equivalent MDCT (p < 0.001). No significant difference was found between LD CBCT and RD MDCT. Conclusions In cadaveric elbow studies, the tested cone-beam CT prototype delivered superior image quality compared to high-end multidetector CT and showed a potential for considerable dose reduction.
Collapse
Affiliation(s)
- Jan-Peter Grunz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany.
| | - Andreas Max Weng
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Andreas Steven Kunz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Maike Veyhl-Wichmann
- Institute of Anatomy and Cell Biology, University of Würzburg, Koellikerstraße 6, 97070, Würzburg, Germany
| | - Rainer Schmitt
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Carsten Herbert Gietzen
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Lenhard Pennig
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany
| | - Stefan Herz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Süleyman Ergün
- Institute of Anatomy and Cell Biology, University of Würzburg, Koellikerstraße 6, 97070, Würzburg, Germany
| | - Thorsten Alexander Bley
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Tobias Gassenmaier
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| |
Collapse
|
4
|
Beck T, Kilchling T, Reese S, Brühschwein A, Meyer-Lindenberg A. Influence of storage on the quality of conventional CT and µCT-imaging for the middle and inner cat ear. Anat Sci Int 2019; 95:190-201. [PMID: 31728859 DOI: 10.1007/s12565-019-00509-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Accepted: 11/04/2019] [Indexed: 10/25/2022]
Abstract
The aim of this study was to analyze whether different fixation methods such as freezing or formaldehyde storage for different periods of time have an influence on the recognition of anatomical relevant structures in the middle and inner ear of the cat with conventional computed tomography (cCT) and micro-computed tomography (µCT). Besides, effects of freeze-thaw cycles on determined structures of the ear were investigated by means of histological slices. Three veterinarians with different radiologic expertise evaluated the scans of 30 dissected cat ears anonymously and scored predefined structures in a five-point scale with reference to visually sharp reproducibility and perfect image quality. The total scores of the different fixation groups as well as the ears within a group were compared with each other. Furthermore, an intra-reader examination including an evaluation of the identifiability of specified structures was performed for both imaging methods. cCT as well as µCT-scans have a very low variation coefficient of 1.6% and 2.3%, respectively. The results for the alterations between the different fixation methods show that the changes for cCT-scans are negligible, as the percentage alteration compared to fresh samples ranges in a very small interval with values from 1.0% better to 1.2% worse. µCT-scans are more influenced by the fixation method with a range from 1.3% better to 6.9% worse values. The scans mostly deteriorated after two freeze-thaw cycles (1.8% worse) and after storing the samples for 1 (2.4% worse), respectively, and 3 weeks in formaldehyde (6.9% worse).
Collapse
Affiliation(s)
- Tobias Beck
- Clinic for Small Animal Surgery and Reproduction, Ludwig-Maximilians-University Munich, Veterinärstraße 13, 80539, Munich, Germany. .,, Wolfratshausen, Germany.
| | - T Kilchling
- Clinic for Small Animal Surgery and Reproduction, Ludwig-Maximilians-University Munich, Veterinärstraße 13, 80539, Munich, Germany.,, Baden-Baden, Germany
| | - S Reese
- Veterinary Department, Institute of Veterinary Anatomy, Histology and Embryology, Ludwig-Maximilians-University Munich, Veterinärstraße 13, 80539, Munich, Germany
| | - A Brühschwein
- Clinic for Small Animal Surgery and Reproduction, Ludwig-Maximilians-University Munich, Veterinärstraße 13, 80539, Munich, Germany
| | - Andrea Meyer-Lindenberg
- Clinic for Small Animal Surgery and Reproduction, Ludwig-Maximilians-University Munich, Veterinärstraße 13, 80539, Munich, Germany
| |
Collapse
|