1
|
Wang TP. Association between TNF-α polymorphisms and the risk of upper gastrointestinal bleeding induced by aspirin in patients with coronary heart disease. Ann Hum Genet 2018; 83:124-133. [PMID: 30506894 DOI: 10.1111/ahg.12295] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2018] [Revised: 10/25/2018] [Accepted: 10/28/2018] [Indexed: 01/17/2023]
Abstract
OBJECTIVE To investigate the correlation of tumor necrosis factor α (TNF-α) polymorphisms with upper gastrointestinal bleeding (UGIB) induced by enteric-coated aspirin in coronary heart disease (CHD) patients. METHODS In total, 154 CHD patients taking enteric-coated aspirin were enrolled in this study. Patients were divided into the UGIB group (n = 57) and non-UGIB group (n = 97) based on the presence or absence of signs of UGIB, respectively. TNF-α polymorphism (-857C > T, -863C > A, and -1031T > C) genotyping was performed using polymerase chain reaction (PCR) amplification with sequence-specific primers (PCR-SSP). RESULTS Patients who had the CC genotype and C allele of -1031T > C exhibited a significantly increase risk of UGIB after receiving enteric-coated aspirin (CC vs. TT: odds (OR) (95% confidence interval (CI)): 7.568 (1.527-37.49), P = 0.005; C vs. T: OR (95% CI): 1.852 (1.036-3.312), P = 0.036). Patients who had CA and CA + AA genotypes and the A allele of -863C > A also exhibited an increased risk of aspirin-induced UGIB (CA vs. CC: OR (95% CI): 2.415 (1.143-5.101), P = 0.019: CA + AA vs. CC: OR (95% CI): 2.218 (1.123-4.381), P = 0.021; A vs. C: OR (95% CI): 1.788 (1.039-3.078), P = 0.035). However, the TNF-α -857 C > T polymorphism was unrelated to the induction of UGIB by enteric-coated aspirin in CHD patients (P > 0.05). In addition, the haplotypes of CCC (-1031T > C, -863C > A, and -857C > T) markedly reduced the risk of aspirin-induced UGIB in CHD patients. CONCLUSION TNF-α -863A and -1031C increased the risk of UGIB induction by enteric-coated aspirin in CHD patients, whereas TNF-α -857C > T was not correlated with the UGIB risk.
Collapse
Affiliation(s)
- Tai-Ping Wang
- Department of Gastroenterology, Rizhao People's Hospital of Shandong Province, Rizhao, 276800, China
| |
Collapse
|
2
|
Contrast agent bolus tracking with a fixed threshold or a manual fast start for coronary CT angiography. Eur Radiol 2014; 24:1229-38. [DOI: 10.1007/s00330-014-3148-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2013] [Revised: 03/04/2014] [Accepted: 03/05/2014] [Indexed: 12/27/2022]
|
3
|
Methodological quality of diagnostic accuracy studies on non-invasive coronary CT angiography: influence of QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) items on sensitivity and specificity. Eur Radiol 2013; 23:1603-22. [PMID: 23322410 DOI: 10.1007/s00330-012-2763-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2012] [Revised: 11/29/2012] [Accepted: 12/10/2012] [Indexed: 12/27/2022]
Abstract
OBJECTIVES To evaluate the methodological quality of diagnostic accuracy studies on coronary computed tomography (CT) angiography using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) tool. METHODS Each QUADAS item was individually defined to adapt it to the special requirements of studies on coronary CT angiography. Two independent investigators analysed 118 studies using 12 QUADAS items. Meta-regression and pooled analyses were performed to identify possible effects of methodological quality items on estimates of diagnostic accuracy. RESULTS The overall methodological quality of coronary CT studies was merely moderate. They fulfilled a median of 7.5 out of 12 items. Only 9 of the 118 studies fulfilled more than 75 % of possible QUADAS items. One QUADAS item ("Uninterpretable Results") showed a significant influence (P = 0.02) on estimates of diagnostic accuracy with "no fulfilment" increasing specificity from 86 to 90 %. Furthermore, pooled analysis revealed that each QUADAS item that is not fulfilled has the potential to change estimates of diagnostic accuracy. CONCLUSIONS The methodological quality of studies investigating the diagnostic accuracy of non-invasive coronary CT is only moderate and was found to affect the sensitivity and specificity. An improvement is highly desirable because good methodology is crucial for adequately assessing imaging technologies. KEY POINTS • Good methodological quality is a basic requirement in diagnostic accuracy studies. • Most coronary CT angiography studies have only been of moderate design quality. • Weak methodological quality will affect the sensitivity and specificity. • No improvement in methodological quality was observed over time. • Authors should consider the QUADAS checklist when undertaking accuracy studies.
Collapse
|
4
|
Springer I, Dewey M. Comparison of multislice computed tomography with intravascular ultrasound for detection and characterization of coronary artery plaques: A systematic review. Eur J Radiol 2009; 71:275-82. [DOI: 10.1016/j.ejrad.2008.04.035] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2007] [Revised: 04/11/2008] [Accepted: 04/23/2008] [Indexed: 11/28/2022]
|
5
|
Reimann AJ, Kuettner A, Klumpp B, Heuschmid M, Schumacher F, Teufel M, Beck T, Burgstahler C, Schröder S, Claussen CD, Kopp AF. Late enhancement using multidetector row computer tomography: A feasibility study with low dose 80kV protocol. Eur J Radiol 2008; 66:127-33. [PMID: 17851011 DOI: 10.1016/j.ejrad.2007.04.013] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2006] [Revised: 10/19/2006] [Accepted: 04/12/2007] [Indexed: 11/21/2022]
Abstract
AIMS Detecting stenoses of coronary arteries with multidetector row computer tomography (MDCT) is a well feasible non-invasive method. However, there is still the problem of deciding whether a stenosis is hemodynamically relevant or not. Objective of the present study was to validate the feasibility of a low dose protocol for MDCT using 80 kV for detecting late enhancement. METHODS AND RESULTS Using a Alderson-Rando Phantom evaluation of the effective dose of this LE protocol was performed. Ten patients (six male, four female, mean age 61) with known coronary artery disease and scheduled for a conventional coronary angiogram in our facility were subsequently recruited. All patients underwent CT-angiography (CTA) 1 day prior to magnetic resonance imaging. Five minutes after the application of 100ml contrast agent for the CTA scan, a low dose late enhancement scan (80 kV, 400 mA s maximum, ECG pulsed scan, 64 mm x 0.6mm collimation, 0.33 s tube rotation) was performed. Phantom dose measurements showed an effective dose for this protocol of 1.19 mSv (male) and 1.61 mSv (female). Fifty-six percent (5/9) of the patients showed a late enhancement on the MRI scan. Three transmural late enhancements and all four negative findings were correctly identified by CT. This represents a sensitivity of 78% (3/5), specificity of 100% (3/3), NPV of 100% (4/4) and a PPV of 97%. CONCLUSION We were able to show that the low dose protocol is feasible and, furthermore, preliminary results look promising.
Collapse
Affiliation(s)
- Anja J Reimann
- Department of Diagnostic Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Abstract
Cardiac imaging with multiple-row detector computed tomography (CT) has become possible due to rapid advances in CT technologies. Images with high temporal and spatial resolution can be obtained with multiple-row detector CT scanners; however, the radiation dose associated with cardiac imaging is high. Understanding the physics of cardiac imaging with multiple-row detector CT scanners allows optimization of cardiac CT protocols in terms of image quality and radiation dose. Knowledge of the trade-offs between various scan parameters that affect image quality--such as temporal resolution, spatial resolution, and pitch--is the key to optimized cardiac CT protocols, which can minimize the radiation risks associated with these studies. Factors affecting temporal resolution include gantry rotation time, acquisition mode, and reconstruction method; factors affecting spatial resolution include detector size and reconstruction interval. Cardiac CT has the potential to become a reliable tool for noninvasive diagnosis and prevention of cardiac and coronary artery disease.
Collapse
Affiliation(s)
- Mahadevappa Mahesh
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD 21287-0856, USA.
| | | |
Collapse
|
7
|
Schnapauff D, Dübel HP, Scholze J, Baumann G, Hamm B, Dewey M. Multislice computed tomography: angiographic emulation versus standard assessment for detection of coronary stenoses. Eur Radiol 2007; 17:1858-64. [PMID: 17206423 DOI: 10.1007/s00330-006-0540-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2006] [Revised: 09/23/2006] [Accepted: 11/24/2006] [Indexed: 11/29/2022]
Abstract
The present study investigated angiographic emulation of multislice computed tomography (MSCT) (catheter-like visualization) as an alternative approach of analyzing and visualizing findings in comparison with standard assessment. Thirty patients (120 coronary arteries) were randomly selected from 90 prospectively investigated patients with suspected coronary artery disease who underwent MSCT (16-slice scanner, 0.5 mm collimation, 400 ms rotation time) prior to conventional coronary angiography for comparison of both approaches. Sensitivity and specificity of angiographic emulation [81% (26/32) and 93% (82/88)] were not significantly different from those of standard assessment [88% (28/32) and 99% (87/88)], while the per-case analysis time was significantly shorter for angiographic emulation than for standard assessment (3.4 +/- 1.5 vs 7.0 +/- 2.5 min, P < 0.001). Both interventional and referring cardiologists preferred angiographic emulation over standard curved multiplanar reformations of MSCT coronary angiography for illustration, mainly because of improved overall lucidity and depiction of sidebranches (P < 0.001). In conclusion, angiographic emulation of MSCT reduces analysis time, yields a diagnostic accuracy comparable to that of standard assessment, and is preferred by cardiologists for visualization of results.
Collapse
Affiliation(s)
- Dirk Schnapauff
- Department of Radiology, Charité - Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Germany
| | | | | | | | | | | |
Collapse
|
8
|
Dewey M, Hamm B. Cost effectiveness of coronary angiography and calcium scoring using CT and stress MRI for diagnosis of coronary artery disease. Eur Radiol 2006; 17:1301-9. [PMID: 17031453 DOI: 10.1007/s00330-006-0439-3] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2006] [Revised: 07/04/2006] [Accepted: 08/10/2006] [Indexed: 10/24/2022]
Abstract
We compared the cost effectiveness of recent approaches [coronary angiography and calcium scoring using computed tomography (CT) and stress magnetic resonance imaging (MRI)] to the diagnosis of coronary artery disease (CAD) with those of the traditional diagnostic modalities [conventional angiography (CATH), exercise ECG, and stress echocardiography] using a decision tree model. For patients with a 10% to 50% pretest likelihood of coronary artery disease, non-invasive coronary angiography using CT was the most cost effective approach, with costs per correctly identified CAD patient of euro4,435 (10% likelihood) to euro1,469 (50% likelihood). Only for a pretest likelihood of 30% to 40% was calcium scoring using CT more cost effective than any of the traditional diagnostic modalities, while MRI was not cost effective for any pretest likelihood. At a pretest likelihood of 60%, CT coronary angiography and CATH were equally effective, while CATH was most cost effective for a pretest likelihood of at least 70%. In conclusion, up to a pretest likelihood for coronary artery disease of 50%, CT coronary angiography is the most cost-effective procedure, being superior to the other new modalities and the most commonly used traditional diagnostic modalities. With a very high likelihood for disease (above 60%), CATH is the most effective procedure from the perspective of society.
Collapse
Affiliation(s)
- Marc Dewey
- Department of Radiology, Charité, Medical School, Humboldt University, Charitéplatz 1, 10117, Berlin, Germany.
| | | |
Collapse
|
9
|
Kato H, Itoh S, Hara T, Sakurai N, Ikeda M. [Evaluation of change in the optimal image reconstruction phase in retrospective ECG-gated reconstruction]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2006; 62:122-9. [PMID: 16456513 DOI: 10.6009/jjrt.62.122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
The purpose of this study was to optimize the reconstruction phase in order to improve depiction of the coronary artery in the relative delay method of the retrospective electrocardiogram (ECG)-gated reconstruction technique using a multi-slice computed tomography (MSCT) scanner with four channels. The following items were evaluated; 1) image quality of the coronary arteriogram, 2) degree of difference between the standard phase corresponding to the diastasis period and the selected phase, which was determined in each case to obtain the best image, and 3) the factors causing the phase difference. The image quality in the selected phase was better than that in the standard phase. A positive correlation was observed between the degree of phase difference and the median value and standard deviation of the heart rate. The degradation of image quality was remarkable in cases showing a large degree of phase difference. A negative correlation was observed between image quality in the selected phase and the degree of phase difference. Individualizing the reconstruction phase is required to improve the image quality of coronary arteriograms with MSCT. It should be noted that the condition of a low and stable heart rate results in reduction in the degree of phase difference, which is useful for the acquisition of better images.
Collapse
Affiliation(s)
- Hideki Kato
- Department of Technical Radiology, Nakatsugawa Municipal General Hospital
| | | | | | | | | |
Collapse
|
10
|
Hackenbroch M, Nehrke K, Gieseke J, Meyer C, Tiemann K, Litt H, Dewald O, Naehle CP, Schild H, Sommer T. 3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography. Eur Radiol 2005; 15:1598-606. [PMID: 15815910 DOI: 10.1007/s00330-005-2731-z] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2004] [Revised: 02/09/2005] [Accepted: 02/28/2005] [Indexed: 10/25/2022]
Abstract
This study aimed to evaluate the influence of a new navigator technique (3D MAG) on navigator efficiency, total acquisition time, image quality and diagnostic accuracy. Fifty-six patients with suspected coronary artery disease underwent free breathing navigator gated coronary MRA (Intera, Philips Medical Systems, 1.5 T, spatial resolution 0.9x0.9x3 mm3) with and without 3D MAG. Evaluation of both sequences included: 1) navigator scan efficiency, 2) total acquisition time, 3) assessment of image quality and 4) detection of stenoses >50%. Average navigator efficiencies of the LCA and RCA were 43+/-12% and 42+/-12% with and 36+/-16% and 35+/-16% without 3D MAG (P<0.01). Scan time was reduced from 12 min 7 s without to 8 min 55 s with 3D MAG for the LCA and from 12 min 19 s to 9 min 7 s with 3D MAG for the RCA (P<0.01). The average scores of image quality of the coronary MRAs with and without 3D MAG were 3.5+/-0.79 and 3.46+/-0.84 (P>0.05). There was no significant difference in the sensitivity and specificity in the detection of coronary artery stenoses between coronary MRAs with and without 3D MAG (P>0.05). 3D MAG provides accelerated acquisition of navigator gated coronary MRA by about 19% while maintaining image quality and diagnostic accuracy.
Collapse
Affiliation(s)
- M Hackenbroch
- Department of Radiology, University of Bonn, Sigmund-Freud-Str. 25, 53105, Bonn, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Koch K, Oellig F, Oberholzer K, Bender P, Kunz P, Mildenberger P, Hake U, Kreitner KF, Thelen M. Assessment of right ventricular function by 16-detector-row CT: comparison with magnetic resonance imaging. Eur Radiol 2004; 15:312-8. [PMID: 15565315 DOI: 10.1007/s00330-004-2543-6] [Citation(s) in RCA: 89] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2004] [Revised: 10/04/2004] [Accepted: 10/07/2004] [Indexed: 01/31/2023]
Abstract
The purpose of this study was to determine right ventricular (RV) function from 16-detector-row CT by using two different software tools in comparison with MRI. Nineteen patients underwent cardiac CT. (1) With semiautomated contour detection software end-diastolic and end-systolic RV volumes were determined from short-axis CT reformations (MPR) created at every 10% of the RR-interval. (2) End-systolic and end-diastolic axial images were transformed to 3D to determine the volumes by using a threshold-supported reconstruction algorithm. Steady-state free-precession cine-MRI of the heart was done in short-axis orientation. RV function could not be analyzed in one patient because of sternal wire artifacts in MRI. Mean end-diastolic (155.4+/-54.6 ml) and end-systolic (79.1+/-37.0 ml) RV volumes determined with MPR correlated well with MRI [151.9+/-53.7 ml (r=0.98) and 75.0+/-36.0 ml (r=0.96), respectively (P<0.001)]. RV stroke volume (76.2+/-20.2 ml for MPR-CT, 76.9+/-20.7 ml for MRI, r=0.93) showed a good correlation and RV ejection fraction (50.8+/-8.4% for MPR-CT, 51.9+/-7.4% for MRI, r=0.74) only a moderate one. Threshold supported 3D reconstructions revealed insufficient correlations with MRI (r=0.31-0.59). MPR-based semiautomated analysis of cardiac 16 detector-row CT allows for RV functional analysis. The results correlate well with MRI findings. Threshold value-supported 3D reconstructions did not show satisfying results because of inhomogeneities of RV contrast enhancement.
Collapse
Affiliation(s)
- K Koch
- Department of Radiology, Johannes Gutenberg-University Mainz, 55131, Mainz, Germany.
| | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Nikolaou K, Flohr T, Stierstorfer K, Becker CR, Reiser MF. Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience. Eur Radiol 2004; 15:329-33. [PMID: 15662479 DOI: 10.1007/s00330-004-2537-4] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2004] [Revised: 09/08/2004] [Accepted: 10/06/2004] [Indexed: 10/26/2022]
Abstract
The aim of this technical investigation was the detailed description of a prototype flat panel detector computed tomography system (FPCT) and its initial evaluation in an ex vivo setting. The prototype FPCT scanner consists of a conventional radiographic flat panel detector, mounted on a multi-slice CT scanner gantry. Explanted human ex vivo heart and foot specimens were examined. Images were reformatted with various reconstruction algorithms and were evaluated for high-resolution anatomic information. For comparison purposes, the ex vivo specimens were also scanned with a conventional 16-detector-row CT scanner (Sensation 16, Siemens Medical Solutions, Forchheim, Germany). With the FPCT prototype used, a 1,024x768 resolution matrix can be obtained, resulting in an isotropic voxel size of 0.25x0.25x0.25 mm at the iso-center. Due to the high spatial resolution, very small structures such as trabecular bone or third-degree, distal branches of coronary arteries could be visualized. This first evaluation showed that flat panel detector systems can be used in a cone-beam computed tomography scanner and that very high spatial resolutions can be achieved. However, there are limitations for in vivo use due to constraints in low contrast resolution and slow scan speed.
Collapse
Affiliation(s)
- Konstantin Nikolaou
- Department of Clinical Radiology, Ludwig-Maximilians-University, Munich, Germany.
| | | | | | | | | |
Collapse
|
13
|
Kuijpers D, Janssen CHC, van Dijkman PRM, Oudkerk M. Dobutamine stress MRI. Part I. Safety and feasibility of dobutamine cardiovascular magnetic resonance in patients suspected of myocardial ischemia. Eur Radiol 2004; 14:1823-8. [PMID: 15278415 DOI: 10.1007/s00330-004-2425-y] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2004] [Revised: 06/16/2004] [Accepted: 06/22/2004] [Indexed: 10/26/2022]
Abstract
The aim of the study was to evaluate safety and feasibility of dobutamine cardiovascular magnetic resonance (CMR) in patients with proven or suspected coronary artery disease. Dobutamine CMR was evaluated retrospectively in 400 consecutive patients with suspicion of myocardial ischemia. Dobutamine was infused using an incremental protocol up to 40 microg/kg body weight per minute. All anti-anginal medication was stopped 4 days before the CMR study and infusion time of dobutamine was 6 min per stage. Hemodynamic data, CMR findings and side effects were reported. Patients with contraindications to CMR (metallic implants and claustrophobia) were excluded from analysis. Dobutamine CMR was successfully performed in 355 (89%) patients. Forty-five (11%) patients could not be investigated adequately because of non-cardiac side effects in 29 (7%) and cardiac side effects in 16 (4%) patients. Hypotension (1.5%) and arrhythmias (1%) were the most frequent cardiac side effects. One patient developed a severe complication (ventricular fibrillation) at the end of the study. There were no myocardial infarctions or fatal complications of the stress test. The most frequent non-cardiac side effects were nausea, vomiting and claustrophobia. Age >70 years, prior myocardial infarction and rest wall motion abnormalities showed no significant differences with side effects (P>0.05). Dobutamine CMR is safe and feasible in patients with suspicion of myocardial ischemia.
Collapse
Affiliation(s)
- Dirkjan Kuijpers
- Department of Radiology, State University and Academic Hospital Groningen, Hanzeplein 1, Groningen, The Netherlands.
| | | | | | | |
Collapse
|
14
|
Kuijpers D, van Dijkman PRM, Janssen CHC, Vliegenthart R, Zijlstra F, Oudkerk M. Dobutamine stress MRI. Part II. Risk stratification with dobutamine cardiovascular magnetic resonance in patients suspected of myocardial ischemia. Eur Radiol 2004; 14:2046-52. [PMID: 15278416 DOI: 10.1007/s00330-004-2426-x] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2004] [Revised: 06/16/2004] [Accepted: 06/22/2004] [Indexed: 10/26/2022]
Abstract
The aim of this study was to determine the prognostic value of dobutamine cardiovascular magnetic resonance (CMR) in patients suspected of myocardial ischemia. Clinical data and dobutamine-CMR results were analyzed in 299 consecutive patients. Follow-up data were analyzed in categories of risk levels defined by the history of coronary artery disease and presence of rest wall motion abnormalities (RWMA). Major adverse cardiac events (MACE) as evaluated end points included cardiac death, nonfatal myocardial infarction and clinically indicated coronary revascularization. Follow-up was completed in 214 (99%) patients with a negative dobutamine-CMR study (no signs of inducible myocardial ischemia) with an average of 24 months. The patients with a negative dobutamine-CMR study and RWMA showed a significantly higher annual MACE rate (18%) than the patients without RWMA (0.56%) ( P<0.001). Patients without RWMA showed an annual MACE rate of 2% when they had a history of coronary artery disease and <0.1% without a previous coronary event ( P<0.001). Dobutamine-CMR showed a positive and negative predictive value of 95 and 93%, respectively. The cardiovascular occurrence-free survival rate was 96.2%. In patients suspected of myocardial ischemia, dobutamine-CMR is able to assess risk levels for coronary events with high accuracy.
Collapse
Affiliation(s)
- Dirkjan Kuijpers
- Department of Radiology and Cardiology, State University and Academic Hospital Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands.
| | | | | | | | | | | |
Collapse
|