1
|
Geddes JR, Randles A. Optimizing Temporal Waveform Analysis: A Novel Pipeline for Efficient Characterization of Left Coronary Artery Velocity Profiles. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2024; 2024:1-4. [PMID: 40039291 DOI: 10.1109/embc53108.2024.10782452] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/06/2025]
Abstract
Continuously measured arterial blood velocity can provide insight into physiological parameters and potential disease states. The efficient and effective description of the temporal profiles of arterial velocity is crucial for both clinical practice and research. We propose a pipeline to identify the minimum number of points of interest to adequately describe a velocity profile of the left coronary artery. This pipeline employs a novel operation that "stretches" a baseline waveform to quantify the utility of a point in fitting other waveforms. Our study introduces a comprehensive pipeline specifically designed to identify the minimal yet crucial number of points needed to accurately represent the velocity profile of the left coronary artery. Additionally, the only location-dependent portion of this pipeline is the first step, choosing all of the possible points of interest. Hence, this work is broadly applicable to other waveforms. This versatility paves the way for a novel non-frequency domain method that can enhance the analysis of physiological waveforms. Such advancements have potential implications in both research and clinical treatment of various diseases, underscoring the broader applicability and impact.
Collapse
|
2
|
Zingaro A, Vergara C, Dede' L, Regazzoni F, Quarteroni A. A comprehensive mathematical model for cardiac perfusion. Sci Rep 2023; 13:14220. [PMID: 37648701 PMCID: PMC10469210 DOI: 10.1038/s41598-023-41312-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Accepted: 08/24/2023] [Indexed: 09/01/2023] Open
Abstract
The aim of this paper is to introduce a new mathematical model that simulates myocardial blood perfusion that accounts for multiscale and multiphysics features. Our model incorporates cardiac electrophysiology, active and passive mechanics, hemodynamics, valve modeling, and a multicompartment Darcy model of perfusion. We consider a fully coupled electromechanical model of the left heart that provides input for a fully coupled Navier-Stokes-Darcy Model for myocardial perfusion. The fluid dynamics problem is modeled in a left heart geometry that includes large epicardial coronaries, while the multicompartment Darcy model is set in a biventricular myocardium. Using a realistic and detailed cardiac geometry, our simulations demonstrate the biophysical fidelity of our model in describing cardiac perfusion. Specifically, we successfully validate the model reliability by comparing in-silico coronary flow rates and average myocardial blood flow with clinically established values ranges reported in relevant literature. Additionally, we investigate the impact of a regurgitant aortic valve on myocardial perfusion, and our results indicate a reduction in myocardial perfusion due to blood flow taken away by the left ventricle during diastole. To the best of our knowledge, our work represents the first instance where electromechanics, hemodynamics, and perfusion are integrated into a single computational framework.
Collapse
Affiliation(s)
- Alberto Zingaro
- MOX, Laboratory of Modeling and Scientific Computing, Dipartimento di Matematica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133, Milano, Italy.
- ELEM Biotech S.L., Pier01, Palau de Mar, Plaça Pau Vila, 1, 08003, Barcelona, Spain.
| | - Christian Vergara
- LaBS, Dipartimento di Chimica, Materiali e Ingegneria Chimica "Giulio Natta", Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133, Milano, Italy
| | - Luca Dede'
- MOX, Laboratory of Modeling and Scientific Computing, Dipartimento di Matematica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133, Milano, Italy
| | - Francesco Regazzoni
- MOX, Laboratory of Modeling and Scientific Computing, Dipartimento di Matematica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133, Milano, Italy
| | - Alfio Quarteroni
- MOX, Laboratory of Modeling and Scientific Computing, Dipartimento di Matematica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133, Milano, Italy
- Institute of Mathematics, École Polytechnique Fédérale de Lausanne, Station 8, Av. Piccard, CH-1015, Lausanne, Switzerland
| |
Collapse
|
3
|
Blanken CPS, Schrauben EM, Peper ES, Gottwald LM, Coolen BF, van Wijk DF, Piek JJ, Strijkers GJ, Planken RN, van Ooij P, Nederveen AJ. Coronary Flow Assessment Using Accelerated 4D Flow MRI With Respiratory Motion Correction. Front Bioeng Biotechnol 2021; 9:725833. [PMID: 34869250 PMCID: PMC8634777 DOI: 10.3389/fbioe.2021.725833] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Accepted: 08/02/2021] [Indexed: 11/29/2022] Open
Abstract
Magnetic resonance imaging (MRI) can potentially be used for non-invasive screening of patients with stable angina pectoris to identify probable obstructive coronary artery disease. MRI-based coronary blood flow quantification has to date only been performed in a 2D fashion, limiting its clinical applicability. In this study, we propose a framework for coronary blood flow quantification using accelerated 4D flow MRI with respiratory motion correction and compressed sensing image reconstruction. We investigate its feasibility and repeatability in healthy subjects at rest. Fourteen healthy subjects received 8 times-accelerated 4D flow MRI covering the left coronary artery (LCA) with an isotropic spatial resolution of 1.0 mm3. Respiratory motion correction was performed based on 1) lung-liver navigator signal, 2) real-time monitoring of foot-head motion of the liver and LCA by a separate acquisition, and 3) rigid image registration to correct for anterior-posterior motion. Time-averaged diastolic LCA flow was determined, as well as time-averaged diastolic maximal velocity (VMAX) and diastolic peak velocity (VPEAK). 2D flow MRI scans of the LCA were acquired for reference. Scan-rescan repeatability and agreement between 4D flow MRI and 2D flow MRI were assessed in terms of concordance correlation coefficient (CCC) and coefficient of variation (CV). The protocol resulted in good visibility of the LCA in 11 out of 14 subjects (six female, five male, aged 28 ± 4 years). The other 3 subjects were excluded from analysis. Time-averaged diastolic LCA flow measured by 4D flow MRI was 1.30 ± 0.39 ml/s and demonstrated good scan-rescan repeatability (CCC/CV = 0.79/20.4%). Time-averaged diastolic VMAX (17.2 ± 3.0 cm/s) and diastolic VPEAK (24.4 ± 6.5 cm/s) demonstrated moderate repeatability (CCC/CV = 0.52/19.0% and 0.68/23.0%, respectively). 4D flow- and 2D flow-based diastolic LCA flow agreed well (CCC/CV = 0.75/20.1%). Agreement between 4D flow MRI and 2D flow MRI was moderate for both diastolic VMAX and VPEAK (CCC/CV = 0.68/20.3% and 0.53/27.0%, respectively). In conclusion, the proposed framework of accelerated 4D flow MRI equipped with respiratory motion correction and compressed sensing image reconstruction enables repeatable diastolic LCA flow quantification that agrees well with 2D flow MRI.
Collapse
Affiliation(s)
- Carmen P S Blanken
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, Amsterdam, Netherlands
| | - Eric M Schrauben
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, Amsterdam, Netherlands
| | - Eva S Peper
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, Amsterdam, Netherlands
| | - Lukas M Gottwald
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, Amsterdam, Netherlands
| | - Bram F Coolen
- Department of Biomedical Engineering and Physics, Amsterdam University Medical Centers, Amsterdam, Netherlands
| | | | - Jan J Piek
- Department of Cardiology, Amsterdam University Medical Centers, Amsterdam, Netherlands
| | - Gustav J Strijkers
- Department of Biomedical Engineering and Physics, Amsterdam University Medical Centers, Amsterdam, Netherlands
| | - R Nils Planken
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, Amsterdam, Netherlands
| | - Pim van Ooij
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, Amsterdam, Netherlands
| | - Aart J Nederveen
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, Amsterdam, Netherlands
| |
Collapse
|
4
|
Hair J, Timmins L, El Sayed R, Samady H, Oshinski J. Effect of Patient-Specific Coronary Flow Reserve Values on the Accuracy of MRI-Based Virtual Fractional Flow Reserve. Front Cardiovasc Med 2021; 8:663767. [PMID: 34277727 PMCID: PMC8282891 DOI: 10.3389/fcvm.2021.663767] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Accepted: 05/28/2021] [Indexed: 01/09/2023] Open
Abstract
The purpose of this study is to investigate the effect of varying coronary flow reserve (CFR) values on the calculation of computationally-derived fractional flow reserve (FFR). CFR reflects both vessel resistance due to an epicardial stenosis, and resistance in the distal microvascular tissue. Patients may have a wide range of CFR related to the tissue substrate that is independent of epicardial stenosis levels. Most computationally based virtual FFR values such as FFRCT do not measure patient specific CFR values but use a population-average value to create hyperemic flow conditions. In this study, a coronary arterial computational geometry was constructed using magnetic resonance angiography (MRA) data acquired in a patient with moderate CAD. Coronary flow waveforms under rest and stress conditions were acquired in 13 patients with phase-contrast magnetic resonance (PCMR) to calculate CFR, and these flow waveforms and CFR values were applied as inlet flow boundary conditions to determine FFR based on computational fluid dynamics (CFD) simulations. The stress flow waveform gave a measure of the functional significance of the vessel when evaluated with the physiologically-accurate behavior with the patient-specific CFR. The resting flow waveform was then scaled by a series of CFR values determined in the 13 patients to simulate how hyperemic flow and CFR affects FFR values. We found that FFR values calculated using non-patient-specific CFR values did not accurately predict those calculated with the true hyperemic flow waveform. This indicates that both patient-specific anatomic and flow information are required to accurately non-invasively assess the functional significance of coronary lesions.
Collapse
Affiliation(s)
- Jackson Hair
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, United States.,Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, United States
| | - Lucas Timmins
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States.,Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, UT, United States
| | - Retta El Sayed
- Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, United States
| | - Habib Samady
- Division of Cardiology, Department of Medicine, Emory School of Medicine, Atlanta, GA, United States
| | - John Oshinski
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, United States.,Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, United States
| |
Collapse
|
5
|
Coronary Endothelial Dysfunction in Women With Type 2 Diabetes Measured by Coronary Phase Contrast Flow Velocity Magnetic Resonance Imaging. J Investig Med 2016; 63:856-61. [PMID: 26230492 DOI: 10.1097/jim.0000000000000226] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The aim of this study was to determine if differences in coronary endothelial function are observed between asymptomatic women with type 2 diabetes mellitus (DM) and control subjects using coronary phase contrast flow velocity magnetic resonance imaging in response to cold pressor stress, an established endothelium-dependent vasodilatory stress. METHODS Phase contrast flow velocity imaging of the right coronary artery was performed in 7 asymptomatic premenopausal women with DM and 8 healthy female participants in response to the cold pressor test at 3 T. RESULTS There was no significant difference in percent increase in coronary flow velocity from rest to peak flow velocity between DM and control subjects (32% ± 22% vs 46% ± 17%; P = 0.11). However, percent increase in coronary flow velocity was lower in DM than in control subjects (-3% ± 14% vs 31% ± 30%; P = 0.01) during the second minute of cold pressor stress, when endothelial-mediated vasodilation should occur. CONCLUSIONS Asymptomatic women with DM demonstrate reduced coronary flow velocity during the second minute of cold pressor stress, indicating coronary endothelial dysfunction.
Collapse
|
6
|
Keegan J, Raphael CE, Parker K, Simpson RM, Strain S, de Silva R, Di Mario C, Collinson J, Stables RH, Wage R, Drivas P, Sugathapala M, Prasad SK, Firmin DN. Validation of high temporal resolution spiral phase velocity mapping of temporal patterns of left and right coronary artery blood flow against Doppler guidewire. J Cardiovasc Magn Reson 2015; 17:85. [PMID: 26428627 PMCID: PMC4591589 DOI: 10.1186/s12968-015-0189-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2015] [Accepted: 09/10/2015] [Indexed: 01/09/2023] Open
Abstract
BACKGROUND Temporal patterns of coronary blood flow velocity can provide important information on disease state and are currently assessed invasively using a Doppler guidewire. A non-invasive alternative would be beneficial as it would allow study of a wider patient population and serial scanning. METHODS A retrospectively-gated breath-hold spiral phase velocity mapping sequence (TR 19 ms) was developed at 3 Tesla. Velocity maps were acquired in 8 proximal right and 15 proximal left coronary arteries of 18 subjects who had previously had a Doppler guidewire study at the time of coronary angiography. Cardiovascular magnetic resonance (CMR) velocity-time curves were processed semi-automatically and compared with corresponding invasive Doppler data. RESULTS When corrected for differences in heart rate between the two studies, CMR mean velocity through the cardiac cycle, peak systolic velocity (PSV) and peak diastolic velocity (PDV) were approximately 40 % of the peak Doppler values with a moderate - good linear relationship between the two techniques (R(2): 0.57, 0.64 and 0.79 respectively). CMR values of PDV/PSV showed a strong linear relationship with Doppler values with a slope close to unity (0.89 and 0.90 for right and left arteries respectively). In individual vessels, plots of CMR velocities at all cardiac phases against corresponding Doppler velocities showed a consistent linear relationship between the two with high R(2) values (mean +/-SD: 0.79 +/-.13). CONCLUSIONS High temporal resolution breath-hold spiral phase velocity mapping underestimates absolute values of coronary flow velocity but allows accurate assessment of the temporal patterns of blood flow.
Collapse
Affiliation(s)
- Jennifer Keegan
- Cardiovascular Biomedical Research Unit, Royal Brompton and Harefield NHS Foundation Trust, London, UK.
| | - Claire E Raphael
- Cardiovascular Biomedical Research Unit, Royal Brompton and Harefield NHS Foundation Trust, London, UK.
| | - Kim Parker
- Department of Bioengineering, Imperial College London, London, UK.
| | - Robin M Simpson
- Radiological Physics, University Medical Centre, Freiburg, Germany.
| | - Stephen Strain
- Cardiovascular Biomedical Research Unit, Royal Brompton and Harefield NHS Foundation Trust, London, UK.
| | - Ranil de Silva
- National Heart and Lung Institute, Imperial College London, London, UK.
- Department of Cardiology, Royal Brompton and Harefield NHS Foundation Trust, London, UK.
| | - Carlo Di Mario
- Department of Cardiology, Royal Brompton and Harefield NHS Foundation Trust, London, UK.
| | - Julian Collinson
- Department of Cardiology, Chelsea and Westminster Hospital, London, UK.
| | - Rod H Stables
- Institue of Cardiovascular Science and Medicine, Liverpool Heart and Chest Hospital, Liverpool, UK.
| | - Ricardo Wage
- Cardiovascular Biomedical Research Unit, Royal Brompton and Harefield NHS Foundation Trust, London, UK.
| | - Peter Drivas
- Cardiovascular Biomedical Research Unit, Royal Brompton and Harefield NHS Foundation Trust, London, UK.
| | - Malindie Sugathapala
- Cardiovascular Biomedical Research Unit, Royal Brompton and Harefield NHS Foundation Trust, London, UK.
| | - Sanjay K Prasad
- Cardiovascular Biomedical Research Unit, Royal Brompton and Harefield NHS Foundation Trust, London, UK.
| | - David N Firmin
- Cardiovascular Biomedical Research Unit, Royal Brompton and Harefield NHS Foundation Trust, London, UK.
- National Heart and Lung Institute, Imperial College London, London, UK.
| |
Collapse
|
7
|
Sun Z, Xu L. Computational fluid dynamics in coronary artery disease. Comput Med Imaging Graph 2014; 38:651-63. [PMID: 25262321 DOI: 10.1016/j.compmedimag.2014.09.002] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2014] [Revised: 08/22/2014] [Accepted: 09/03/2014] [Indexed: 01/01/2023]
Abstract
Computational fluid dynamics (CFD) is a widely used method in mechanical engineering to solve complex problems by analysing fluid flow, heat transfer, and associated phenomena by using computer simulations. In recent years, CFD has been increasingly used in biomedical research of coronary artery disease because of its high performance hardware and software. CFD techniques have been applied to study cardiovascular haemodynamics through simulation tools to predict the behaviour of circulatory blood flow in the human body. CFD simulation based on 3D luminal reconstructions can be used to analyse the local flow fields and flow profiling due to changes of coronary artery geometry, thus, identifying risk factors for development and progression of coronary artery disease. This review aims to provide an overview of the CFD applications in coronary artery disease, including biomechanics of atherosclerotic plaques, plaque progression and rupture; regional haemodynamics relative to plaque location and composition. A critical appraisal is given to a more recently developed application, fractional flow reserve based on CFD computation with regard to its diagnostic accuracy in the detection of haemodynamically significant coronary artery disease.
Collapse
Affiliation(s)
- Zhonghua Sun
- Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University, Perth, Western Australia 6845, Australia.
| | - Lei Xu
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
| |
Collapse
|
8
|
Computational fluid dynamics simulations of contrast agent bolus dispersion in a coronary bifurcation: impact on MRI-based quantification of myocardial perfusion. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2013; 2013:513187. [PMID: 23533541 PMCID: PMC3600257 DOI: 10.1155/2013/513187] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/14/2012] [Accepted: 01/05/2013] [Indexed: 11/18/2022]
Abstract
Contrast-enhanced first-pass magnetic resonance imaging (MRI) in combination with a tracer kinetic model, for example, MMID4, can be used to determine myocardial blood flow (MBF) and myocardial perfusion reserve (MPR). Typically, the arterial input function (AIF) required for this methodology is estimated from the left ventricle (LV). Dispersion of the contrast agent bolus might occur between the LV and the myocardial tissue. Negligence of bolus dispersion could cause an error in MBF determination. The aim of this study was to investigate the influence of bolus dispersion in a simplified coronary bifurcation geometry including one healthy and one stenotic branch on the quantification of MBF and MPR. Computational fluid dynamics (CFD) simulations were combined with MMID4. Different inlet boundary conditions describing pulsatile and constant flows for rest and hyperemia and differing outflow conditions have been investigated. In the bifurcation region, the increase of the dispersion was smaller than inside the straight vessels. A systematic underestimation of MBF values up to -16.1% for pulsatile flow and an overestimation of MPR up to 7.5% were found. It was shown that, under the conditions considered in this study, bolus dispersion can significantly influence the results of quantitative myocardial MR-perfusion measurements.
Collapse
|
9
|
Jiraraksopakun Y, McDougall MP, Wright SM, Ji JX. A flow quantification method using fluid dynamics regularization and MR tagging. IEEE Trans Biomed Eng 2010; 57:1437-45. [PMID: 20172815 DOI: 10.1109/tbme.2009.2038229] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
This paper presents a new method for improved flow analysis and quantification using MRI. The method incorporates fluid dynamics to regularize the flow quantification from tagged MR images. Specifically, the flow quantification is formulated as a minimization problem based on the following: 1) the Navier-Stokes equation governing the fluid dynamics; 2) the flow continuity equation and boundary conditions; and 3) the data consistency constraint. The minimization is carried out using a genetic algorithm. This method is tested using both computer simulations and MR flow experiments. The results are evaluated using flow vector fields from the computational fluid dynamics software package as a reference, which show that the new method can achieve more realistic and accurate flow quantifications than the conventional method.
Collapse
Affiliation(s)
- Yuttapong Jiraraksopakun
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843, USA.
| | | | | | | |
Collapse
|
10
|
Coronary artery flow measurement using navigator echo gated phase contrast magnetic resonance velocity mapping at 3.0 T. J Biomech 2007; 41:595-602. [PMID: 18036532 DOI: 10.1016/j.jbiomech.2007.10.010] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2007] [Revised: 10/11/2007] [Accepted: 10/13/2007] [Indexed: 11/21/2022]
Abstract
A validation study and early results for non-invasive, in vivo measurement of coronary artery blood flow using phase contrast magnetic resonance imaging (PC-MRI) at 3.0T is presented. Accuracy of coronary artery blood flow measurements by phase contrast MRI is limited by heart and respiratory motion as well as the small size of the coronary arteries. In this study, a navigator echo gated, cine phase velocity mapping technique is described to obtain time-resolved velocity and flow waveforms of small diameter vessels at 3.0T. Phantom experiments using steady, laminar flow are presented to validate the technique and show flow rates measured by 3.0T phase contrast MRI to be accurate within 15% of true flow rates. Subsequently, in vivo scans on healthy volunteers yield velocity measurements for blood flow in the right, left anterior descending, and left circumflex arteries. Measurements of average, cross-sectional velocity were obtainable in 224/243 (92%) of the cardiac phases. Time-averaged, cross-sectional velocity of the blood flow was 6.8+/-4.3cm/s in the LAD, 8.0+/-3.8cm/s in the LCX, and 6.0+/-1.6cm/s in the RCA.
Collapse
|
11
|
Bakhtiary F, Schiemann M, Dzemali O, Dogan S, Schächinger V, Ackermann H, Moritz A, Kleine P. Impact of patient-prosthesis mismatch and aortic valve design on coronary flow reserve after aortic valve replacement. J Am Coll Cardiol 2007; 49:790-6. [PMID: 17306709 DOI: 10.1016/j.jacc.2006.10.052] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2006] [Revised: 09/13/2006] [Accepted: 10/16/2006] [Indexed: 11/19/2022]
Abstract
OBJECTIVES This prospective-randomized study investigated the effect of aortic valve design and patient-prosthesis mismatch (PPM) on coronary flow reserve (CFR) after mechanical or biological aortic valve replacement (AVR) in patients with aortic stenosis (AS). BACKGROUND Coronary flow reserve may be an important parameter of long-term survival after AVR in patients with AS. Reduced CFR may contribute to more cardiovascular events and greater rates of mortality. METHODS A total of 48 patients undergoing AVR underwent magnetic resonance imaging for the measurement of coronary flow preoperatively, 5 days postoperatively, and at 6-month follow-up with measurement of CFR. Patients scheduled for mechanical AVR were randomized to a tilting disc or bileaflet prosthesis (n = 12 in each group). For biological AVR, patients were scheduled to receive a stented (n = 12) or stentless (n = 12) valve. Patients also underwent echocardiography with measurement of transvalvular pressure gradients and left ventricular mass regression. RESULTS Postoperatively, coronary flow increased significantly in all groups (p < 0.001). Only stentless valves demonstrated a normal CFR (3.4 +/- 0.3 vs. 2.3 +/- 0.1 for stented biological valves, 2.1 +/- 0.2 for tilting disc, and 2.2 +/- 0.3 for bileaflet mechanical valves). Patient-prosthesis mismatch with an indexed effective orifice area <0.85 cm2/m2 led to decreased rates of CFR in the tilting disc, stentless, and stented groups. Pressure gradients were 14 +/- 3 mm Hg for tilting disc, 12 +/- 4 mm Hg for bileaflet, 19 +/- 6 mm Hg for stented, and 10 +/- 4 mm Hg for stentless valves. CONCLUSIONS Normalization of CFR after AVR in patients with AS was observed only for stentless valves. Coronary flow reserve might explain the excellent long-term results for stentless valves. (Impact of Patient-Prosthesis Mismatch on Coronary Flow Reserve; http://www.clinicaltrials.gov/ct/show/NCT00310947?order=1; NCT00310947).
Collapse
Affiliation(s)
- Farhad Bakhtiary
- Department of Thoracic and Cardiovascular Surgery, Johann Wolfgang Goethe University Hospital, Frankfurt/Main, Germany.
| | | | | | | | | | | | | | | |
Collapse
|