1
|
Tang L, Diao K, Deng Q, Wu X, Peng P, Yue X, Wu T, Cheng W, Li Y, Zhou X, Wetzl J, Chen Y, Yue W, Sun J. Comparison between pre- and post-contrast cardiac MRI cine images: the impact on ventricular volume and strain measurement. THE INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING 2023; 39:1055-1064. [PMID: 36840896 DOI: 10.1007/s10554-023-02809-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Accepted: 02/04/2023] [Indexed: 02/26/2023]
Abstract
To explore whether contrast agent administration will affect ventricular volume and strain parameters measured on cardiac magnetic resonance cine images. This prospective study enrolled 88 patients, including 32 patients with cardiac amyloidosis (CA), 32 patients with hypertrophic cardiomyopathy (HCM), and 24 control participants, to perform steady-state free precession (SSFP)-cine imaging twice, respectively before and after contrast agent injection. Indexed left and right ventricular (LV and RV) volume and LV strain parameters (peak radial strain [PRS], peak circumferential strain [PCS], peak longitudinal strain [PLS]) were analyzed and compared between the pre- and post-contrast cine groups. Compared to the group of pre-contrast cine, the end-diastolic volume index (EDVi) and end-systolic volume index (ESVi) significantly increased in the group using post-contrast cine images (all p < 0.05), especially in the right ventricle. After contrast injection, the right ventricular ejection fraction (RVEF) decreased significantly (p < 0.05), while the left ventricular ejection fraction (LVEF) only reduced for patients with HCM (p < 0.05). The PRS (37.1 ± 15.2 vs. 32.0 ± 15.4, p < 0.001) and PCS (- 14.9 ± 4.3 vs. - 14.0 ± 4.1, p < 0.001) derived from post-contrast cine images reduced significantly in all patients and this tendency remained in subgroup analysis except for PCS in the control group. The administration of a contrast agent may influence the measurements of ventricular volume and strain. Acquiring pre-contrast cine images were suggested for patients who required more accurate right ventricle evaluation or precise strain assessment.
Collapse
Affiliation(s)
- Lu Tang
- Department of Radiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, 610041, Sichuan, China
| | - Kaiyue Diao
- Department of Radiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, 610041, Sichuan, China
| | - Qiao Deng
- Department of Radiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, 610041, Sichuan, China
| | - Xi Wu
- Department of Radiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, 610041, Sichuan, China
| | - Pengfei Peng
- Department of Radiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, 610041, Sichuan, China
| | - Xun Yue
- Department of Radiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, 610041, Sichuan, China
| | - Tao Wu
- Department of Radiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, 610041, Sichuan, China
| | - Wei Cheng
- Department of Radiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, 610041, Sichuan, China
| | - Yangjie Li
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | - Xiaoyue Zhou
- MR Collaboration, Siemens Healthineers Ltd, Shanghai, China
| | - Jens Wetzl
- MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany
| | - Yucheng Chen
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | - Wenjun Yue
- Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| | - Jiayu Sun
- Department of Radiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, 610041, Sichuan, China.
| |
Collapse
|
2
|
Cholet C, Damy T, Legou F, Kobeiter H, Rahmouni A, Deux JF. Quantification of Myocardial Enhancement on Cine-MRI: Diagnostic Value in Cardiac Amyloidosis. Acad Radiol 2019; 26:e98-e107. [PMID: 30072291 DOI: 10.1016/j.acra.2018.06.021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2018] [Revised: 06/25/2018] [Accepted: 06/25/2018] [Indexed: 01/15/2023]
Abstract
RATIONALE AND OBJECTIVES Diagnosis of cardiac amyloidosis (CA) on cardiac magnetic resonance (CMR) can be challenging and quantitative indexes are relevant to further characterize the myocardium. We hypothesize that the relative myocardial enhancement measured from pre and post contrast cine imaging provides diagnostic information for CA in the setting of left ventricular hypertrophy (LVH). MATERIALS AND METHODS Patients with LVH referred to our center and control subjects with normal CMR were retrospectively included. Percentage of myocardial enhancement (percentage ME) was obtained from pre and post contrast (5 minutes) cine sequences. Post contrast myocardial T1 and LGE extent were also recorded. RESULTS Twenty-one patients with CA, 25 patients with non-amyloid left ventricular myocardial hypertrophy (CH) and 20 controls with normal CMR were analyzed. Percentage ME was significantly higher in CA patients (200% (174-238)) than in CH patients (122% (88-151); p = 0.0001) and control patients (104% (90-149); p = 0.0001). Percentage ME was significantly correlated with the LGE extent (Rho Spearman coefficient = 0.66; p = 0.0001) and with the post contrast myocardial T1 (Rho Spearman coefficient = -0.61; p = 0.0001). With a cutoff value of 152%, the sensitivity and specificity of percentage ME for detection of CA were 90% and 80%, respectively. CONCLUSION Percentage ME obtained from pre and post contrast cine imaging is correlated to LGE extent and myocardial T1 and may represent an additional diagnostic parameter to consider CA in patients with LVH.
Collapse
Affiliation(s)
- Clément Cholet
- Assistance Publique - Hôpitaux de Paris (AP-HP), Service d'Imagerie Médicale, CHU Henri Mondor, 51 avenue du Maréchal de Lattre de Tassigny, Créteil, 94010, France.
| | - Thibaud Damy
- Assistance Publique - Hôpitaux de Paris (AP-HP), Service de Cardiologie, CHU Henri Mondor, 51 avenue du Maréchal de Lattre de Tassigny, Créteil, 94010, France; Université Paris-Est Créteil (UPEC), Créteil, 94010, France; GRC Amyloid Research Institute and Réseau Amylose Mondor, CHU Henri Mondor, UPEC, Créteil, 94010, France; DHU, ATVB, UPEC, Créteil, 94010, France.
| | - François Legou
- Assistance Publique - Hôpitaux de Paris (AP-HP), Service d'Imagerie Médicale, CHU Henri Mondor, 51 avenue du Maréchal de Lattre de Tassigny, Créteil, 94010, France.
| | - Hicham Kobeiter
- Assistance Publique - Hôpitaux de Paris (AP-HP), Service d'Imagerie Médicale, CHU Henri Mondor, 51 avenue du Maréchal de Lattre de Tassigny, Créteil, 94010, France; Université Paris-Est Créteil (UPEC), Créteil, 94010, France; DHU, ATVB, UPEC, Créteil, 94010, France.
| | - Alain Rahmouni
- Assistance Publique - Hôpitaux de Paris (AP-HP), Service d'Imagerie Médicale, CHU Henri Mondor, 51 avenue du Maréchal de Lattre de Tassigny, Créteil, 94010, France; Université Paris-Est Créteil (UPEC), Créteil, 94010, France.
| | - Jean-François Deux
- Assistance Publique - Hôpitaux de Paris (AP-HP), Service d'Imagerie Médicale, CHU Henri Mondor, 51 avenue du Maréchal de Lattre de Tassigny, Créteil, 94010, France; Université Paris-Est Créteil (UPEC), Créteil, 94010, France; GRC Amyloid Research Institute and Réseau Amylose Mondor, CHU Henri Mondor, UPEC, Créteil, 94010, France; DHU, ATVB, UPEC, Créteil, 94010, France.
| |
Collapse
|
3
|
Bayer T, Adler W, Janka R, Uder M, Roemer F. Magnetic resonance cinematography of the fingers: a 3.0 Tesla feasibility study with comparison of incremental and continuous dynamic protocols. Skeletal Radiol 2017; 46:1721-1728. [PMID: 28821929 DOI: 10.1007/s00256-017-2742-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2017] [Revised: 06/16/2017] [Accepted: 07/24/2017] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To study the feasibility of magnetic resonance cinematography of the fingers (MRCF) with comparison of image quality of different protocols for depicting the finger anatomy during motion. MATERIALS AND METHODS MRCF was performed during a full flexion and extension movement in 14 healthy volunteers using a finger-gating device. Three real-time sequences (frame rates 17-59 images/min) and one proton density (PD) sequence (3 images/min) were acquired during incremental and continuous motion. Analyses were performed independently by three readers. Qualitative image analysis included Likert-scale grading from 0 (useless) to 5 (excellent) and specific visual analog scale (VAS) grading from 0 (insufficient) to 100 (excellent). Signal-to-noise calculation was performed. Overall percentage agreement and mean absolute disagreement were calculated. RESULTS Within the real-time sequences a high frame-rate true fast imaging with steady-state free precession (TRUFI) yielded the best image quality with Likert and overall VAS scores of 3.0 ± 0.2 and 60.4 ± 25.3, respectively. The best sequence regarding image quality was an incremental PD with mean values of 4.8 ± 0.2 and 91.2 ± 9.4, respectively. Overall percentage agreement and mean absolute disagreement were 47.9 and 0.7, respectively. No statistically significant SNR differences were found between continuous and incremental motion for the real-time protocols. CONCLUSION MRCF is feasible with appropriate image quality during continuous motion using a finger-gating device. Almost perfect image quality is achievable with incremental PD imaging, which represents a compromise for MRCF with the drawback of prolonged scanning time.
Collapse
Affiliation(s)
- Thomas Bayer
- Department of Radiology, University of Erlangen-Nuremberg, Maximiliansplatz 1, 91054, Erlangen, Germany.
| | - Werner Adler
- IMBE, University of Erlangen-Nuremberg, Erlangen, Germany
| | - Rolf Janka
- Department of Radiology, University of Erlangen-Nuremberg, Maximiliansplatz 1, 91054, Erlangen, Germany
| | - Michael Uder
- Department of Radiology, University of Erlangen-Nuremberg, Maximiliansplatz 1, 91054, Erlangen, Germany
| | - Frank Roemer
- Department of Radiology, University of Erlangen-Nuremberg, Maximiliansplatz 1, 91054, Erlangen, Germany
| |
Collapse
|
4
|
D’Angelo T, Grigoratos C, Mazziotti S, Bratis K, Pathan F, Blandino A, Elen E, Puntmann VO, Nagel E. High-throughput gadobutrol-enhanced CMR: a time and dose optimization study. J Cardiovasc Magn Reson 2017; 19:83. [PMID: 29110679 PMCID: PMC5674223 DOI: 10.1186/s12968-017-0400-4] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2017] [Accepted: 10/16/2017] [Indexed: 01/05/2023] Open
Abstract
BACKGROUND Reducing time and contrast agent doses are important goals to provide cost-efficient cardiovascular magnetic resonance (CMR) imaging. Limited information is available regarding the feasibility of evaluating left ventricular (LV) function after gadobutrol injection as well as defining the lowest dose for high quality scar imaging. We sought to evaluate both aspects separately and systematically to provide an optimized protocol for contrast-enhanced CMR (CE-CMR) using gadobutrol. METHODS This is a prospective, randomized, single-blind cross-over study performed in two different populations. The first population consisted of 30 patients with general indications for a rest CE-CMR who underwent cine-imaging before and immediately after intravenous administration of 0.1 mmol/kg body-weight of gadobutrol. Quantitative assessment of LV volumes and function was performed by the same reader in a randomized and blinded fashion. The second population was composed of 30 patients with indication to late gadolinium enhancement (LGE) imaging, which was performed twice at different gadobutrol doses (0.1 mmol/kg vs. 0.2 mmol/kg) and at different time delays (5 and 10 min vs. 5, 10, 15 and 20 min), within a maximal interval of 21 days. LGE images were analysed qualitatively (contrast-to-noise ratio) and quantitatively (LGE%-of-mass). RESULTS Excellent correlation between pre- and post-contrast cine-imaging was found, with no difference of LV stroke volume and ejection fraction (p = 0.538 and p = 0.095, respectively). End-diastolic-volume and end-systolic-volume were measured significantly larger after contrast injection (p = 0.008 and p = 0.001, respectively), with a mean difference of 3.7 ml and 2.9 ml, respectively. LGE imaging resulted in optimal contrast-to-noise ratios 10 min post-injection for a gadobutrol dose of 0.1 mmol/kg body-weight and 20 min for a dose of 0.2 mmol/kg body-weight. At these time points LGE quantification did not significantly differ (0.1 mmol/kg: 11% (16.4); 0.2 mmol/kg: 12% (14.5); p = 0.059), showing excellent correlation (ICC = 0.957; p < 0.001). CONCLUSION A standardized CE-CMR rest protocol giving a dose of 0.1 mmol/kg of gadobutrol before cine-imaging and performing LGE 10 min after injection represents a fast low-dose protocol without significant loss of information in comparison to a longer protocol with cine-imaging before contrast injection and a higher dose of gadobutrol. This approach allows to reduce examination time and costs as well as minimize contrast-agent exposure.
Collapse
Affiliation(s)
- Tommaso D’Angelo
- Department of Biomedical Sciences and Morphological and Functional Imaging, G. Martino University Hospital Messina, Via Consolare Valeria, 1, 98100 Messina, Italy
- Institute for Experimental and Translational Cardiovascular Imaging, DZHK Centre for Cardiovascular Imaging, University Hospital Frankfurt, Theodor-Stern- Kai 7, Frankfurt am Main, Germany
| | - Chrysanthos Grigoratos
- G. Monasterio CNR-Tuscany Foundation, Pisa, Italy
- Department of Cardiovascular Imaging, King’s College London, Lambeth Wing, St. Thomas’ Hospital, London, UK
| | - Silvio Mazziotti
- Department of Biomedical Sciences and Morphological and Functional Imaging, G. Martino University Hospital Messina, Via Consolare Valeria, 1, 98100 Messina, Italy
| | - Konstantinos Bratis
- Department of Cardiovascular Imaging, King’s College London, Lambeth Wing, St. Thomas’ Hospital, London, UK
| | - Faraz Pathan
- Institute for Experimental and Translational Cardiovascular Imaging, DZHK Centre for Cardiovascular Imaging, University Hospital Frankfurt, Theodor-Stern- Kai 7, Frankfurt am Main, Germany
- Department of Cardiology, Menzies Institute for Medical Research, University of Tasmania, Hobart, Australia
| | - Alfredo Blandino
- Department of Biomedical Sciences and Morphological and Functional Imaging, G. Martino University Hospital Messina, Via Consolare Valeria, 1, 98100 Messina, Italy
| | - Elen Elen
- Institute for Experimental and Translational Cardiovascular Imaging, DZHK Centre for Cardiovascular Imaging, University Hospital Frankfurt, Theodor-Stern- Kai 7, Frankfurt am Main, Germany
- Department of Cardiology, National Cardiovascular Center Harapan Kita, Universitas Indonesia, Jakarta, Indonesia
| | - Valentina O. Puntmann
- Institute for Experimental and Translational Cardiovascular Imaging, DZHK Centre for Cardiovascular Imaging, University Hospital Frankfurt, Theodor-Stern- Kai 7, Frankfurt am Main, Germany
- Department of Cardiovascular Imaging, King’s College London, Lambeth Wing, St. Thomas’ Hospital, London, UK
- Department of Cardiology, University Hospital Frankfurt, DZHK Rhein-Main, Theodor-Stern- Kai 7, Frankfurt am Main, Germany
| | - Eike Nagel
- Institute for Experimental and Translational Cardiovascular Imaging, DZHK Centre for Cardiovascular Imaging, University Hospital Frankfurt, Theodor-Stern- Kai 7, Frankfurt am Main, Germany
- Department of Cardiovascular Imaging, King’s College London, Lambeth Wing, St. Thomas’ Hospital, London, UK
- Department of Cardiology, University Hospital Frankfurt, DZHK Rhein-Main, Theodor-Stern- Kai 7, Frankfurt am Main, Germany
| |
Collapse
|
5
|
Amano Y, Yanagisawa F, Tachi M, Asai K, Suzuki Y, Hashimoto H, Ishihara K, Kumita S. Three-dimensional Cardiac MR Imaging: Related Techniques and Clinical Applications. Magn Reson Med Sci 2017; 16:183-189. [PMID: 28202854 PMCID: PMC5600024 DOI: 10.2463/mrms.rev.2016-0116] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
Three-dimensional (3D) cardiac magnetic resonance (MR) imaging has several advantages, including the easy coverage of the entire heart without misregistration, reduction of breath-holding times, and availability for postprocessing reconstruction. These advantages are associated with some techniques such as breath-hold or navigator gating and parallel imaging. However, the image quality of 3D cardiac MR images is compromised by the use of a shorter repetition time and parallel imaging. Thus, a steady-state free precession sequence, contrast agent administration, and presaturation pulses are used to maintain the image quality. In this review, we introduce the MR imaging techniques used in 3D cardiac MR imaging and demonstrate the typical 3D cardiac MR images, followed by discussion about their advantages and disadvantages.
Collapse
Affiliation(s)
- Yasuo Amano
- Department of Radiology, Nihon University Hospital.,Department of Radiology, Nippon Medical School
| | - Fumi Yanagisawa
- Department of Radiology, Nihon University Hospital.,Department of Radiology, Nippon Medical School
| | | | - Kuniya Asai
- Department of Cardiology, Nippon Medical School
| | | | - Hidenobu Hashimoto
- Department of Radiology, Nihon University Hospital.,Department of Cardiology, Toho University Omori Medical Center
| | | | | |
Collapse
|
6
|
Caspar T, Schultz A, Schaeffer M, Labani A, Jeung MY, Jurgens PT, El Ghannudi S, Roy C, Ohana M. Left Ventricular Function Evaluation on a 3T MR Scanner with Parallel RF Transmission Technique: Prospective Comparison of Cine Sequences Acquired before and after Gadolinium Injection. PLoS One 2016; 11:e0163503. [PMID: 27669571 PMCID: PMC5036819 DOI: 10.1371/journal.pone.0163503] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2016] [Accepted: 09/09/2016] [Indexed: 12/02/2022] Open
Abstract
Objectives To compare cine MR b-TFE sequences acquired before and after gadolinium injection, on a 3T scanner with a parallel RF transmission technique in order to potentially improve scanning time efficiency when evaluating LV function. Methods 25 consecutive patients scheduled for a cardiac MRI were prospectively included and had their b-TFE cine sequences acquired before and right after gadobutrol injection. Images were assessed qualitatively (overall image quality, LV edge sharpness, artifacts and LV wall motion) and quantitatively with measurement of LVEF, LV mass, and telediastolic volume and contrast-to-noise ratio (CNR) between the myocardium and the cardiac chamber. Statistical analysis was conducted using a Bayesian paradigm. Results No difference was found before or after injection for the LVEF, LV mass and telediastolic volume evaluations. Overall image quality and CNR were significantly lower after injection (estimated coefficient cine after > cine before gadolinium: -1.75 CI = [-3.78;-0.0305], prob(coef>0) = 0% and -0.23 CI = [-0.49;0.04], prob(coef>0) = 4%) respectively), but this decrease did not affect the visual assessment of LV wall motion (cine after > cine before gadolinium: -1.46 CI = [-4.72;1.13], prob(coef>0) = 15%). Conclusions In 3T cardiac MRI acquired with parallel RF transmission technique, qualitative and quantitative assessment of LV function can reliably be performed with cine sequences acquired after gadolinium injection, despite a significant decrease in the CNR and the overall image quality.
Collapse
Affiliation(s)
- Thibault Caspar
- Cardiology Department, Nouvel Hôpital Civil, Strasbourg University Hospital, Strasbourg, France
- * E-mail:
| | - Anthony Schultz
- Radiology Department, Nouvel Hôpital Civil, Strasbourg University Hospital, Strasbourg, France
| | - Mickaël Schaeffer
- Public Health and Biostatistics Department, Nouvel Hôpital Civil, Strasbourg University Hospital, Strasbourg, France
| | - Aïssam Labani
- Radiology Department, Nouvel Hôpital Civil, Strasbourg University Hospital, Strasbourg, France
| | - Mi-Young Jeung
- Radiology Department, Nouvel Hôpital Civil, Strasbourg University Hospital, Strasbourg, France
| | | | - Soraya El Ghannudi
- Radiology Department, Nouvel Hôpital Civil, Strasbourg University Hospital, Strasbourg, France
- iCube Laboratory, Université de Strasbourg / CNRS, UMR 7357, 67400, Illkirch, France
| | - Catherine Roy
- Radiology Department, Nouvel Hôpital Civil, Strasbourg University Hospital, Strasbourg, France
| | - Mickaël Ohana
- Radiology Department, Nouvel Hôpital Civil, Strasbourg University Hospital, Strasbourg, France
- iCube Laboratory, Université de Strasbourg / CNRS, UMR 7357, 67400, Illkirch, France
| |
Collapse
|
7
|
Amano Y, Yamada F, Kitamura M, Tachi M, Mine K, Kumita S, Takayama M. Contrast-enhanced Steady-state Free Precession in the Assessment of Hypertrophic Obstructive Cardiomyopathy after Alcohol Septal Ablation. Magn Reson Med Sci 2015; 15:130-6. [PMID: 26346399 DOI: 10.2463/mrms.2015-0037] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
PURPOSE We evaluated the feasibility of contrast-enhanced steady-state free precession (ceSSFP) in the assessment of myocardial injury and obstruction of the left ventricular outflow tract (LVOT) in patients with hypertrophic obstructive cardiomyopathy (HOCM) after alcohol septal ablation (ASA). METHODS Twelve patients with HOCM underwent 16 magnetic resonance (MR) examinations following ASA. Precontrast SSFP, ceSSFP and late gadolinium enhancement (LGE) imaging were performed with a 1.5-tesla imager. ceSSFP was performed 3 to 7 min after gadolinium injection. We visually and quantitatively evaluated the signal patterns of the myocardium after ASA on SSFP and LGE MR imaging. We observed the LVOT using ceSSFP in the 3-chamber view. RESULTS We could visualize ASA-induced myocardial infarction (MI) in all 16 studies by LGE and ceSSFP but in only 6 studies (37.5%) by precontrast SSFP. Contrast was higher between MI and remote myocardium with LGE than ceSSFP (P < 0.01). ASA-induced hypointense regions were well visualized by the 2 sequences after contrast in the 7 patients who underwent MR imaging within 7 weeks of ASA and in a few patients after 80 weeks from ASA. The ceSSFP allowed comparable visualization of the jet flow crossing the LVOT to that derived from echocardiographic data. CONCLUSION Contrast-enhanced steady-state free precession allows assessment of myocardial injury as well as of the left ventricular outflow tract after alcohol septal ablation in a single scan without penalty in scan time and cine imaging contrast.
Collapse
Affiliation(s)
- Yasuo Amano
- Department of Radiology, Nippon Medical School
| | | | | | | | | | | | | |
Collapse
|
8
|
Fernández-Pérez G, Franco López Á, García Fernández M, Corral de la Calle M, Encinas de la Iglesia J, Velasco Casares M. Función sistólica del ventrículo izquierdo: cómo comprenderla y analizarla. RADIOLOGIA 2014; 56:505-14. [DOI: 10.1016/j.rx.2013.09.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2013] [Revised: 09/09/2013] [Accepted: 09/20/2013] [Indexed: 11/29/2022]
|
9
|
Acute Myocarditis: Diagnostic Value of Contrast-Enhanced Cine Steady-State Free Precession MRI Sequences. AJR Am J Roentgenol 2011; 197:1081-7. [DOI: 10.2214/ajr.10.6031] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
10
|
Bibliography. Current world literature. Imaging and echocardiography. Curr Opin Cardiol 2008; 23:512-5. [PMID: 18670264 DOI: 10.1097/hco.0b013e32830d843f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
11
|
Detection of mechanical ventricular asynchrony by high temporal resolution cine MRI. Eur Radiol 2008; 18:1329-37. [DOI: 10.1007/s00330-008-0888-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2007] [Revised: 01/15/2008] [Accepted: 01/28/2008] [Indexed: 10/22/2022]
|
12
|
Busch S, Johnson TRC, Wintersperger BJ, Minaifar N, Bhargava A, Rist C, Reiser MF, Becker C, Nikolaou K. Quantitative assessment of left ventricular function with dual-source CT in comparison to cardiac magnetic resonance imaging: initial findings. Eur Radiol 2007; 18:570-5. [PMID: 17909817 DOI: 10.1007/s00330-007-0767-y] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2007] [Revised: 08/03/2007] [Accepted: 08/28/2007] [Indexed: 10/22/2022]
Abstract
Cardiac magnetic resonance imaging and echocardiography are currently regarded as standard modalities for the quantification of left ventricular volumes and ejection fraction. With the recent introduction of dual-source computedtomography (DSCT), the increased temporal resolution of 83 ms should also improve the assessment of cardiac function in CT. The aim of this study was to evaluate the accuracy of DSCT in the assessment of left ventricular functional parameters with cardiac magnetic resonance imaging (MRI) as standard of reference. Fifteen patients (two female, 13 male; mean age 50.8 +/- 19.2 years) underwent CT and MRI examinations on a DSCT (Somatom Definition; Siemens Medical Solutions, Forchheim, Germany) and a 3.0-Tesla MR scanner (Magnetom Trio; Siemens Medical Solutions), respectively. Multiphase axial CT images were analysed with a semiautomatic region growing algorithms (Syngo Circulation; Siemens Medical Solutions) by two independent blinded observers. In MRI, dynamic cine loops of short axis slices were evaluated with semiautomatic contour detection software (ARGUS; Siemens Medical Solutions) independently by two readers. End-systolic volume (ESV), end-diastolic volume (EDV), ejection fraction (EF) and stroke volume (SV) were determined for both modalities, and correlation coefficient, systematic error, limits of agreement and inter-observer variability were assessed. In DSCT, EDV and ESV were 135.8 +/- 41.9 ml and 54.9 +/- 29.6 ml, respectively, compared with 132.1 +/- 40.8 ml EDV and 57.6 +/- 27.3 ml ESV in MRI. Thus, EDV was overestimated by 3.7 ml (limits of agreement -46.1/+53.6), while ESV was underestimated by 2.6 ml (-36.6/+31.4). Mean EF was 61.6 +/- 12.4% in DSCT and 57.9 +/- 9.0% in MRI, resulting in an overestimation of EF by 3.8% with limits of agreement at -14.7 and +22.2%. Rank correlation rho values were 0.81 for EDV (P = 0.0024), 0.79 for ESV (P = 0.0031) and 0.64 for EF (P = 0.0168). The kappa value of inter-observer variability were amounted to 0.85 for EDV, ESV and EF. DSCT offers the possibility to quantify left ventricular function from coronary CT angiography datasets with sufficient diagnostic accuracy, adding to the value of the modality in a comprehensive cardiac assessment. The observed differences in the measured values may be due to different post-processing methods and physiological reactions to contrast material injection without beta-blocker medication.
Collapse
Affiliation(s)
- S Busch
- Department of Clinical Radiology, University of Munich, Marchioninistr. 15, 81377, Munich, Germany.
| | | | | | | | | | | | | | | | | |
Collapse
|