1
|
Zhang Y, Zhang X, Jiang Y, Yang P, Hu X, Peng B, Yue X, Li Y, Ma P, Yuan Y, Yu Y, Liu B, Li X. 3D whole-heart noncontrast coronary MR angiography based on compressed SENSE technology: a comparative study of conventional SENSE sequence and coronary computed tomography angiography. Insights Imaging 2023; 14:35. [PMID: 36790611 PMCID: PMC9931966 DOI: 10.1186/s13244-023-01378-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Accepted: 01/20/2023] [Indexed: 02/16/2023] Open
Abstract
OBJECTIVE The relatively long scan time has hampered the clinical use of whole-heart noncontrast coronary magnetic resonance angiography (NCMRA). The compressed sensitivity encoding (SENSE) technique, also known as the CS technique, has been found to improve scan times. This study aimed to identify the optimal CS acceleration factor for NCMRA. METHODS Thirty-six participants underwent four NCMRA sequences: three sequences using the CS technique with acceleration factors of 4, 5, and 6, and one sequence using the conventional SENSE technique with the acceleration factor of 2. Coronary computed tomography angiography (CCTA) was considered as a reference sequence. The acquisition times of the four NCMRA sequences were assessed. The correlation and agreement between the visible vessel lengths obtained via CCTA and NCMRA were also assessed. The image quality scores and contrast ratio (CR) of eight coronary artery segments from the four NCMRA sequences were quantitatively evaluated. RESULTS The mean acquisition time of the conventional SENSE was 343 s, while that of CS4, CS5, and CS6 was 269, 215, and 190 s, respectively. The visible vessel length from the CS4 sequence showed good correlation and agreement with CCTA. The image quality score and CR from the CS4 sequence were not statistically significantly different from those in the other groups (p > 0.05). Moreover, the image score and CR showed a decreasing trend with the increase in the CS factor. CONCLUSIONS The CS technique could significantly shorten the acquisition time of NCMRA. The CS sequence with an acceleration factor of 4 was generally acceptable for NCMRA in clinical settings to balance the image quality and acquisition time.
Collapse
Affiliation(s)
- Yang Zhang
- grid.412679.f0000 0004 1771 3402Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, 230032 Anhui Province China ,Department of Radiology, Fuyang People’s Hospital, Fuyang, 236015 Anhui Province China
| | - Xinna Zhang
- grid.412679.f0000 0004 1771 3402Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, 230032 Anhui Province China
| | - Yuqi Jiang
- grid.186775.a0000 0000 9490 772XDepartment of Radiology, Fuyang Hospital of Anhui Medical University, Fuyang, 236000 Anhui China
| | - Panpan Yang
- grid.186775.a0000 0000 9490 772XDepartment of Radiology, Fuyang Hospital of Anhui Medical University, Fuyang, 236000 Anhui China
| | - Xiankuo Hu
- Department of Radiology, Fuyang People’s Hospital, Fuyang, 236015 Anhui Province China
| | - Bin Peng
- Department of Radiology, Fuyang People’s Hospital, Fuyang, 236015 Anhui Province China
| | | | - Yuanyuan Li
- Department of Radiology, Fuyang People’s Hospital, Fuyang, 236015 Anhui Province China
| | - Peiqi Ma
- Department of Radiology, Fuyang People’s Hospital, Fuyang, 236015 Anhui Province China
| | - Yushan Yuan
- Department of Radiology, Fuyang People’s Hospital, Fuyang, 236015 Anhui Province China
| | - Yongqiang Yu
- grid.412679.f0000 0004 1771 3402Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, 230032 Anhui Province China
| | - Bin Liu
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, 230032, Anhui Province, China.
| | - Xiaohu Li
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, 230032, Anhui Province, China. .,Department of Radiology, Fuyang Hospital of Anhui Medical University, Fuyang, 236000, Anhui, China.
| |
Collapse
|