1
|
Long M, Li Y, He H, Gu N. The Story of Ferumoxytol: Synthesis Production, Current Clinical Applications, and Therapeutic Potential. Adv Healthc Mater 2024; 13:e2302773. [PMID: 37931150 DOI: 10.1002/adhm.202302773] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 11/01/2023] [Indexed: 11/08/2023]
Abstract
Ferumoxytol, approved by the U.S. Food and Drug Administration in 2009, is one of the intravenous iron oxide nanoparticles authorized for the treatment of iron deficiency in chronic kidney disease and end-stage renal disease. With its exceptional magnetic properties, catalytic activity, and immune activity, as well as good biocompatibility and safety, ferumoxytol has gained significant recognition in various biomedical diagnoses and treatments. Unlike most existing reviews on this topic, this review primarily focuses on the recent clinical and preclinical advances of ferumoxytol in disease treatment, spanning anemia, cancer, infectious inflammatory diseases, regenerative medicine application, magnetic stimulation for neural modulation, etc. Additionally, the newly discovered mechanisms associated with the biological effects of ferumoxytol are discussed, including its magnetic, catalytic, and immunomodulatory properties. Finally, the summary and future prospects concerning the treatment and application of ferumoxytol-based nanotherapeutics are presented.
Collapse
Affiliation(s)
- Mengmeng Long
- Jiangsu Key Laboratory for Biomaterials and Devices, School of Biomedical Sciences and Medical Engineering, Southeast University, Nanjing, 210096, P. R. China
| | - Yan Li
- Jiangsu Key Laboratory for Biomaterials and Devices, School of Biomedical Sciences and Medical Engineering, Southeast University, Nanjing, 210096, P. R. China
| | - Hongliang He
- Jiangsu Key Laboratory for Biomaterials and Devices, School of Biomedical Sciences and Medical Engineering, Southeast University, Nanjing, 210096, P. R. China
| | - Ning Gu
- Jiangsu Key Laboratory for Biomaterials and Devices, School of Biomedical Sciences and Medical Engineering, Southeast University, Nanjing, 210096, P. R. China
- Medical School, Nanjing University, Nanjing, 210008, P. R. China
| |
Collapse
|
2
|
Abstract
Many labs have been developing cellular magnetic resonance imaging (MRI), using both superparamagnetic iron oxide nanoparticles (SPIONs) and fluorine-19 (19F)-based cell labels, to track immune and stem cells used for cellular therapies. Although SPION-based MRI cell tracking has very high sensitivity for cell detection, SPIONs are indirectly detected owing to relaxation effects on protons, producing negative magnetic resonance contrast with low signal specificity. Therefore, it is not possible to reliably quantify the local tissue concentration of SPION particles, and cell number cannot be determined. 19F-based cell tracking has high specificity for perfluorocarbon-labeled cells, and 19F signal is directly related to cell number. However, 19F MRI has low sensitivity. Magnetic particle imaging (MPI) is a new imaging modality that directly detects SPIONs. SPION-based cell tracking using MPI displays great potential for overcoming the challenges of MRI-based cell tracking, allowing for both high cellular sensitivity and specificity, and quantification of SPION-labeled cell number. Here we describe nanoparticle and MPI system factors that influence MPI sensitivity and resolution, quantification methods, and give our perspective on testing and applying MPI for cell tracking.
Collapse
Affiliation(s)
- Olivia C. Sehl
- Imaging Research Laboratories, Robarts Research Institute; and
- Department of Medical Biophysics, University of Western Ontario, London, ON, Canada
| | - Julia J. Gevaert
- Imaging Research Laboratories, Robarts Research Institute; and
- Department of Medical Biophysics, University of Western Ontario, London, ON, Canada
| | - Kierstin P. Melo
- Imaging Research Laboratories, Robarts Research Institute; and
- Department of Medical Biophysics, University of Western Ontario, London, ON, Canada
| | - Natasha N. Knier
- Imaging Research Laboratories, Robarts Research Institute; and
- Department of Medical Biophysics, University of Western Ontario, London, ON, Canada
| | - Paula J. Foster
- Imaging Research Laboratories, Robarts Research Institute; and
- Department of Medical Biophysics, University of Western Ontario, London, ON, Canada
| |
Collapse
|
3
|
Negi H, Takeuchi S, Kamei N, Yanada S, Adachi N, Ochi M. In Vitro Safety and Quality of Magnetically Labeled Human Mesenchymal Stem Cells Preparation for Cartilage Repair. Tissue Eng Part C Methods 2019; 25:324-333. [PMID: 31002015 DOI: 10.1089/ten.tec.2019.0001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
Abstract
IMPACT STATEMENT This study is very important for a preclinical assessment of the safety and quality of magnetically labeled mesenchymal stem cells (MSCs) for use in cartilage repair. The findings of this study show that magnetic labeling with an appropriate density of magnetic particles has no harmful effects on the safety and quality of MSCs.
Collapse
Affiliation(s)
- Hiroshi Negi
- 1 Department of Orthopaedic Surgery, Graduate School of Biomedical & Health Sciences, Hiroshima University, Hiroshima, Japan
| | | | - Naosuke Kamei
- 1 Department of Orthopaedic Surgery, Graduate School of Biomedical & Health Sciences, Hiroshima University, Hiroshima, Japan.,3 Medical Center for Translational and Clinical Research, Hiroshima University Hospital, Hiroshima, Japan
| | | | - Nobuo Adachi
- 1 Department of Orthopaedic Surgery, Graduate School of Biomedical & Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Mitsuo Ochi
- 4 Hiroshima University, Higashihiroshima, Japan
| |
Collapse
|
4
|
Chandrasekharan P, Tay ZW, Zhou XY, Yu E, Orendorff R, Hensley D, Huynh Q, Fung KLB, VanHook CC, Goodwill P, Zheng B, Conolly S. A perspective on a rapid and radiation-free tracer imaging modality, magnetic particle imaging, with promise for clinical translation. Br J Radiol 2018; 91:20180326. [PMID: 29888968 DOI: 10.1259/bjr.20180326] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Magnetic particle imaging (MPI), introduced at the beginning of the twenty-first century, is emerging as a promising diagnostic tool in addition to the current repertoire of medical imaging modalities. Using superparamagnetic iron oxide nanoparticles (SPIOs), that are available for clinical use, MPI produces high contrast and highly sensitive tomographic images with absolute quantitation, no tissue attenuation at-depth, and there are no view limitations. The MPI signal is governed by the Brownian and Néel relaxation behavior of the particles. The relaxation time constants of these particles can be utilized to map information relating to the local microenvironment, such as viscosity and temperature. Proof-of-concept pre-clinical studies have shown favourable applications of MPI for better understanding the pathophysiology associated with vascular defects, tracking cell-based therapies and nanotheranostics. Functional imaging techniques using MPI will be useful for studying the pathology related to viscosity changes such as in vascular plaques and in determining cell viability of superparamagnetic iron oxide nanoparticle labeled cells. In this review article, an overview of MPI is provided with discussions mainly focusing on MPI tracers, applications of translational capabilities ranging from diagnostics to theranostics and finally outline a promising path towards clinical translation.
Collapse
Affiliation(s)
| | - Zhi Wei Tay
- 1 Department of Bioengineering, University of California , Berkeley, CA , USA
| | - Xinyi Yedda Zhou
- 1 Department of Bioengineering, University of California , Berkeley, CA , USA
| | - Elaine Yu
- 2 Magnetic Insight Inc , Alameda, CA , USA
| | | | | | - Quincy Huynh
- 1 Department of Bioengineering, University of California , Berkeley, CA , USA
| | - K L Barry Fung
- 1 Department of Bioengineering, University of California , Berkeley, CA , USA
| | | | | | - Bo Zheng
- 1 Department of Bioengineering, University of California , Berkeley, CA , USA
| | - Steven Conolly
- 1 Department of Bioengineering, University of California , Berkeley, CA , USA.,3 Department of Electrical Engineering and Computer Sciences, University of California , Berkeley, CA , USA
| |
Collapse
|
5
|
Kilian T, Fidler F, Kasten A, Nietzer S, Landgraf V, Weiß K, Walles H, Westphal F, Hackenberg S, Grüttner C, Steinke M. Stem cell labeling with iron oxide nanoparticles: impact of 3D culture on cell labeling maintenance. Nanomedicine (Lond) 2016; 11:1957-70. [PMID: 27456272 DOI: 10.2217/nnm-2016-0042] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
AIM We aimed to analyze the suitability of nanoparticles (M4E) for safe human mesenchymal stem cell (hMSC) labeling and determined cell labeling maintenance in 2D and 3D culture. MATERIALS & METHODS We investigated cell-particle interaction and the particles' impact on cell viability, growth and proliferation. We analyzed cell labeling maintenance in 2D and 3D culture invasively and noninvasively. RESULTS M4E do not affect cell viability, growth and proliferation and do not cause chromosomal aberrations. Cell labeling maintenance is up to five-times higher in 3D conditions compared with 2D culture. CONCLUSION M4E allow safe hMSC labeling and noninvasive identification. Our hMSC-loaded, 3D tissue-engineered construct could serve as a graft for regenerative therapies, in which M4E-labeled hMSCs can migrate to their target.
Collapse
Affiliation(s)
- Teresa Kilian
- Fraunhofer Institute for Interfacial Engineering & Biotechnology IGB, Translational Center "Regenerative Therapies for Oncology & Musculoskeletal Diseases" - Würzburg branch, Röntgenring 11, 97070 Würzburg, Germany
| | - Florian Fidler
- Research Center Magnetic-Resonance-Bavaria, Am Hubland, 97074 Würzburg, Germany
| | - Annika Kasten
- Department of Oral & Maxillofacial Surgery, Facial Plastic Surgery, Rostock University Medical Center, Schillingallee 35, 18057 Rostock, Germany
| | - Sarah Nietzer
- Tissue Engineering & Regenerative Medicine, University Hospital Würzburg, Röntgenring 11, 97070 Würzburg, Germany
| | - Veronika Landgraf
- Tissue Engineering & Regenerative Medicine, University Hospital Würzburg, Röntgenring 11, 97070 Würzburg, Germany
| | - Katrin Weiß
- Tissue Engineering & Regenerative Medicine, University Hospital Würzburg, Röntgenring 11, 97070 Würzburg, Germany
| | - Heike Walles
- Fraunhofer Institute for Interfacial Engineering & Biotechnology IGB, Translational Center "Regenerative Therapies for Oncology & Musculoskeletal Diseases" - Würzburg branch, Röntgenring 11, 97070 Würzburg, Germany.,Tissue Engineering & Regenerative Medicine, University Hospital Würzburg, Röntgenring 11, 97070 Würzburg, Germany
| | - Fritz Westphal
- Micromod Partikeltechnologie GmbH, Friedrich-Barnewitz-Straße 4, 18119 Rostock, Germany
| | - Stephan Hackenberg
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic & Reconstructive Head & Neck Surgery, University Hospital Würzburg, Josef-Schneider-Straße 11, 97080 Würzburg, Germany
| | - Cordula Grüttner
- Micromod Partikeltechnologie GmbH, Friedrich-Barnewitz-Straße 4, 18119 Rostock, Germany
| | - Maria Steinke
- Fraunhofer Institute for Interfacial Engineering & Biotechnology IGB, Translational Center "Regenerative Therapies for Oncology & Musculoskeletal Diseases" - Würzburg branch, Röntgenring 11, 97070 Würzburg, Germany.,Tissue Engineering & Regenerative Medicine, University Hospital Würzburg, Röntgenring 11, 97070 Würzburg, Germany
| |
Collapse
|
6
|
Zhou B, Li D, Qian J, Li Z, Pang P, Shan H. MR tracking of SPIO-labeled mesenchymal stem cells in rats with liver fibrosis could not monitor the cells accurately. CONTRAST MEDIA & MOLECULAR IMAGING 2015; 10:473-80. [PMID: 26153152 DOI: 10.1002/cmmi.1650] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2015] [Revised: 04/13/2015] [Accepted: 05/18/2015] [Indexed: 01/31/2023]
Abstract
Our previous study showed that in vivo magnetic resonance (MR) imaging is effective in tracking superparamagnetic iron oxide (SPIO)-labeled bone marrow mesenchymal stem cells (BMSCs) in rats with liver fibrosis. SPIO-labeling-induced signal reduction on MR images was completely reversed within 15 days after transplantation. It is still unclear whether the signal changes in MR imaging could reflect the number of transplanted cells in the liver. In the present study, BMSCs of male rats were doubly labeled with enhanced green fluorescent protein (EGFP) and SPIO and injected intravascularly into female rats with liver fibrosis. At different time points after injection, MR imaging was performed. The distribution of SPIO particles and EGFP-positive cells was determined by Prussian blue staining and EGFP immunohistochemistry, respectively. The distribution of transplanted BMSCs in various organs was assessed by detection of the SRY gene using real-time quantitative PCR. At 15 days post transplantation, the numbers of transplanted cells were significantly decreased in the lung, kidney, spleen and muscle, but not liver and heart, in comparison with those at 7 days after transplantation. EGFP staining-positive cells were observed in the liver intralobular parenchyma, while Prussian blue staining was negative at 42 days after transplantation. Taken together, SPIO particles and EGFP-labeled BMSCs show a different tissue distribution pattern in rats with liver fibrosis after a long-term period of monitoring. SPIO-based MR imaging may not be suitable for long-term tracking of transplanted BMSCs in vivo.
Collapse
Affiliation(s)
- Bin Zhou
- Department of Radiology, Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China.,Guangdong Provincial Engineering Research Center of Molecular Imaging, Guangzhou, China
| | - Dan Li
- Department of Radiology, Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China.,Guangdong Provincial Engineering Research Center of Molecular Imaging, Guangzhou, China
| | - Jiesheng Qian
- Department of Radiology, Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China.,Guangdong Provincial Engineering Research Center of Molecular Imaging, Guangzhou, China
| | - Zhengran Li
- Department of Radiology, Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China.,Guangdong Provincial Engineering Research Center of Molecular Imaging, Guangzhou, China
| | - Pengfei Pang
- Department of Radiology, Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China.,Guangdong Provincial Engineering Research Center of Molecular Imaging, Guangzhou, China
| | - Hong Shan
- Department of Radiology, Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China.,Guangdong Provincial Engineering Research Center of Molecular Imaging, Guangzhou, China.,Interventional Radiology Institute, Sun Yat-sen University, Guangzhou, China
| |
Collapse
|
7
|
Skopalik J, Polakova K, Havrdova M, Justan I, Magro M, Milde D, Knopfova L, Smarda J, Polakova H, Gabrielova E, Vianello F, Michalek J, Zboril R. Mesenchymal stromal cell labeling by new uncoated superparamagnetic maghemite nanoparticles in comparison with commercial Resovist--an initial in vitro study. Int J Nanomedicine 2014; 9:5355-72. [PMID: 25484583 PMCID: PMC4245086 DOI: 10.2147/ijn.s66986] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVE Cell therapies have emerged as a promising approach in medicine. The basis of each therapy is the injection of 1-100×10(6) cells with regenerative potential into some part of the body. Mesenchymal stromal cells (MSCs) are the most used cell type in the cell therapy nowadays, but no gold standard for the labeling of the MSCs for magnetic resonance imaging (MRI) is available yet. This work evaluates our newly synthesized uncoated superparamagnetic maghemite nanoparticles (surface-active maghemite nanoparticles - SAMNs) as an MRI contrast intracellular probe usable in a clinical 1.5 T MRI system. METHODS MSCs from rat and human donors were isolated, and then incubated at different concentrations (10-200 μg/mL) of SAMN maghemite nanoparticles for 48 hours. Viability, proliferation, and nanoparticle uptake efficiency were tested (using fluorescence microscopy, xCELLigence analysis, atomic absorption spectroscopy, and advanced microscopy techniques). Migration capacity, cluster of differentiation markers, effect of nanoparticles on long-term viability, contrast properties in MRI, and cocultivation of labeled cells with myocytes were also studied. RESULTS SAMNs do not affect MSC viability if the concentration does not exceed 100 μg ferumoxide/mL, and this concentration does not alter their cell phenotype and long-term proliferation profile. After 48 hours of incubation, MSCs labeled with SAMNs show more than double the amount of iron per cell compared to Resovist-labeled cells, which correlates well with the better contrast properties of the SAMN cell sample in T2-weighted MRI. SAMN-labeled MSCs display strong adherence and excellent elasticity in a beating myocyte culture for a minimum of 7 days. CONCLUSION Detailed in vitro tests and phantom tests on ex vivo tissue show that the new SAMNs are efficient MRI contrast agent probes with exclusive intracellular uptake and high biological safety.
Collapse
Affiliation(s)
- Josef Skopalik
- Department of Pharmacology, Masaryk University, Brno, Czech Republic
| | - Katerina Polakova
- Regional Centre of Advanced Technologies and Materials, Department of Physical Chemistry and Analytical Chemistry, Faculty of Science, Palacky University, Olomouc, Czech Republic
| | - Marketa Havrdova
- Regional Centre of Advanced Technologies and Materials, Department of Physical Chemistry and Analytical Chemistry, Faculty of Science, Palacky University, Olomouc, Czech Republic
| | - Ivan Justan
- Department of Pharmacology, Masaryk University, Brno, Czech Republic
| | - Massimiliano Magro
- Department of Comparative Biomedicine and Food Science, University of Padua, Padova, Italy
| | - David Milde
- Regional Centre of Advanced Technologies and Materials, Department of Physical Chemistry and Analytical Chemistry, Faculty of Science, Palacky University, Olomouc, Czech Republic
| | - Lucia Knopfova
- Department of Experimental Biology, Faculty of Science, Masaryk University, Brno, Czech Republic
| | - Jan Smarda
- Department of Experimental Biology, Faculty of Science, Masaryk University, Brno, Czech Republic
| | - Helena Polakova
- Department of Pharmacology, Masaryk University, Brno, Czech Republic
| | - Eva Gabrielova
- Department of Medical Chemistry and Biochemistry, Faculty of Medicine, Palacky University, Olomouc, Czech Republic
| | - Fabio Vianello
- Regional Centre of Advanced Technologies and Materials, Department of Physical Chemistry and Analytical Chemistry, Faculty of Science, Palacky University, Olomouc, Czech Republic
- Department of Comparative Biomedicine and Food Science, University of Padua, Padova, Italy
| | - Jaroslav Michalek
- Department of Pharmacology, Masaryk University, Brno, Czech Republic
| | - Radek Zboril
- Regional Centre of Advanced Technologies and Materials, Department of Physical Chemistry and Analytical Chemistry, Faculty of Science, Palacky University, Olomouc, Czech Republic
| |
Collapse
|
8
|
Abstract
About 43 million individuals in the US currently suffer from disabilities due to arthritis. Cartilage defects are the major source of pain in the affected joints. Current treatments, whilst alleviating some of the clinical symptoms, prove insufficient to cure the underlying irreversible cartilage loss. Stem cells represent a unique source for restoration of cartilage defects. Pre-clinical and clinical trials are currently pursued to investigate the potential of various types of stem cells and stem cell derived chondrocytes to repair arthritic joints. A major challenge with all stem cell-mediated tissue regeneration approaches is death of the transplanted cells with clearance by the immune system. Our current inability to diagnose successful or unsuccessful engraftment of transplanted cells non-invasively in vivo represents a major bottleneck for the development of successful stem cell therapies. A large variety of non-invasive Magnetic Resonance (MR) imaging techniques have been developed over the last decade, which enable sensitive in vivo detection of Matrix Associated Stem Cell Implants (MASI) and early diagnosis of related complications. While initially focused on successfully harvesting cellular MR imaging approaches with easily applicable SuperParamagnetic Iron Oxide Nanoparticles (SPIO), our team began to observe details that will facilitate clinical translation. We therefore started a broader effort to define a comprehensive set of novel, clinically applicable imaging approaches for stem cell transplants in patients. We established immediately clinically applicable nanoparticle labeling techniques for tracking stem cell transplants with MR imaging; we have evaluated the long term MR signal effects of iron oxide nanoparticle labeled MASI in vivo; and we have defined distinct signal characteristics of labeled viable and apoptotic MASI. This review article will provide an overview over these efforts and discuss important implications for clinical translation.
Collapse
Affiliation(s)
- Heike E Daldrup-Link
- Department of Radiology and Molecular Imaging Program at Stanford (MIPS), Stanford School of Medicine, 725 Welch Rd, Rm 1665; Stanford, USA
| | - Hossein Nejadnik
- Department of Radiology and Molecular Imaging Program at Stanford (MIPS), Stanford School of Medicine, 725 Welch Rd, Rm 1665; Stanford, USA
| |
Collapse
|
9
|
Jülke H, Veit C, Ribitsch I, Brehm W, Ludewig E, Delling U. Comparative Labeling of Equine and Ovine Multipotent Stromal Cells With Superparamagnetic Iron Oxide Particles for Magnetic Resonance Imaging In Vitro. Cell Transplant 2013; 24:1111-25. [PMID: 24330785 DOI: 10.3727/096368913x675737] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
The purpose of this study was to evaluate the use of three different superparamagnetic iron oxide (SPIO) particles for labeling of ovine and equine bone marrow (BM)-derived multipotent stromal cells (MSCs) in vitro. MSCs were obtained from five adult sheep and horses, respectively. After three passages (p3), cells were labeled with either 1) Molday ION Rhodamine B, 2) Endorem, 3) Resovist, or 4) remained unlabeled as control. Labeling efficiency, marker retention, and long-term detectability in MRI until p7 were evaluated. Further, proliferation capacity and trilineage differentiation as indicators for potential impact on stromal cell characteristics were assessed. MSCs of both species were successfully labeled with all three SPIO products. A high, exclusively intracellular, iron uptake was achieved by Molday ION Rhodamine B only. Labeling with Resovist led to prominent extracellular iron presence; labeling with Endorem was less efficient. During MRI, all labeled cells showed strong hypointense signals, contrary to unlabeled controls. Resovist induced the largest areas of hypointense signals, followed by Molday ION Rhodamine B and Endorem. MRI signal detectability decreased from p4 to p7. Proliferation, adipogenic, and osteogenic differentiation potential were not reduced by cell labeling compared to unlabeled cells. Chondrogenic differentiation capacity decreased with increasing amount of iron associated with the cells. Among the three products, Resovist and Molday were identified as promising labeling agents. While Resovist achieved superior results in most of the assessed parameters, Molday ION Rhodamine B ensured intracellular iron uptake without extracellular SPIO complexes and consistent hypointense signals on MRI.
Collapse
Affiliation(s)
- Henriette Jülke
- Translational Centre for Regenerative Medicine (TRM), University of Leipzig, Leipzig, Germany
| | | | | | | | | | | |
Collapse
|
10
|
Markides H, Kehoe O, Morris RH, El Haj AJ. Whole body tracking of superparamagnetic iron oxide nanoparticle-labelled cells--a rheumatoid arthritis mouse model. Stem Cell Res Ther 2013; 4:126. [PMID: 24406201 PMCID: PMC3854718 DOI: 10.1186/scrt337] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2013] [Accepted: 10/11/2013] [Indexed: 12/29/2022] Open
Abstract
Introduction The application of mesenchymal stem cells (MSCs) in treating rheumatoid arthritis (RA) has been made possible by the immunosuppressive and differentiation abilities of these cells. A non-invasive means of assessing cell integration and bio-distribution is fundamental in evaluating the risks and success of this therapy, thereby enabling clinical translation. This paper defines the use of superparamagnetic iron oxide nanoparticles (SPIONs) in conjunction with magnetic resonance imaging (MRI) to image and track MSCs in vivo within a murine model of RA. Methods Murine MSCs (mMSCs) were isolated, expanded and labelled with SiMAG, a commercially available particle. In vitro MRI visibility thresholds were investigated by labelling mMSCs with SiMAG with concentrations ranging from 0 to 10 μg/ml and resuspending varying cell doses (103 to 5 × 105 cells) in 2 mg/ml collagen prior to MR-imaging. Similarly, in vivo detection thresholds were identified by implanting 3 × 105 mMSCs labelled with 0 to 10 μg/ml SiMAG within the synovial cavity of a mouse and MR-imaging. Upon RA induction, 300,000 mMSCs labelled with SiMAG (10 μg/ml) were implanted via intra-articular injection and joint swelling monitored as an indication of RA development over seven days. Furthermore, the effect of SiMAG on cell viability, proliferation and differentiation was investigated. Results A minimum particle concentration of 1 μg/ml (300,000 cells) and cell dose of 100,000 cells (5 and 10 μg/ml) were identified as the in vitro MRI detection threshold. Cell viability, proliferation and differentiation capabilities were not affected, with labelled populations undergoing successful differentiation down osteogenic and adipogenic lineages. A significant decrease (P < 0.01) in joint swelling was measured in groups containing SiMAG-labelled and unlabelled mMSCs implying that the presence of SPIONs does not affect the immunomodulating properties of the cells. In vivo MRI scans demonstrated good contrast and the identification of SiMAG-labelled populations within the synovial joint up to 7 days post implantation. This was further confirmed using histological analysis. Conclusions We have been able to monitor and track the migration of stem cell populations within the rheumatic joint in a non-invasive manner. This manuscript goes further to highlight the key characteristics (biocompatible and the ability to create significant contrast at realistic doses within a clinical relevant system) demonstrated by SiMAG that should be incorporated into the design of a new clinically approved tracking agent.
Collapse
|
11
|
Thu MS, Bryant LH, Coppola T, Jordan EK, Budde MD, Lewis BK, Chaudhry A, Ren J, Varma NRS, Arbab AS, Frank JA. Self-assembling nanocomplexes by combining ferumoxytol, heparin and protamine for cell tracking by magnetic resonance imaging. Nat Med 2012; 18:463-7. [PMID: 22366951 PMCID: PMC3296876 DOI: 10.1038/nm.2666] [Citation(s) in RCA: 162] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2011] [Accepted: 08/04/2011] [Indexed: 12/11/2022]
Abstract
We report on a novel and straightforward magnetic cell labeling approach that combines three FDA-approved drugs, ferumoxytol (F), heparin (H) and protamine (P) in serum free media to form self-assembling nanocomplexes that effectively label cells for in vivo MRI. We observed that the HPF nanocomplexes were stable in serum free cell culture media. HPF nanocomplexes exhibited a three-fold increase in T2 relaxivity compared to F. Electron Microscopy revealed internalized HPF within endosomes, confirmed by Prussian blue staining of labeled cells. There was no long-term effect or toxicity on cellular physiology or function of HPF-labeled hematopoietic stem cells, bone marrow stromal cells, neural stem cells, and T-cells when compared to controls. In vivo MRI detected 1000 HPF-labeled cells implanted in rat brains. HPF labeling method should facilitate the monitoring by MRI of infused or implanted cells in clinical trials.
Collapse
Affiliation(s)
- Mya S Thu
- Frank Laboratory and Laboratory of Diagnostic Radiology Research, Department of Radiology and Imaging Sciences, US National Institutes of Health, Bethesda, Maryland, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Taylor A, Wilson KM, Murray P, Fernig DG, Lévy R. Long-term tracking of cells using inorganic nanoparticles as contrast agents: are we there yet? Chem Soc Rev 2012; 41:2707-17. [PMID: 22362426 DOI: 10.1039/c2cs35031a] [Citation(s) in RCA: 138] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
The use of inorganic nanoparticles as probes to label and track cells in vivo is already a reality. While superparamagnetic nanoparticles have been the subject of clinical studies involving magnetic resonance imaging, quantum dots and gold nanoparticles are starting to be explored for similar goals in pre-clinical studies involving fluorescence and photoacoustic imaging. Although exciting results have been obtained from in vivo investigations, there appears to be a general lack of understanding on the effects of physicochemical properties on the labelling efficiency and toxicity of those nanoparticles, as well as on their stability in the intracellular microenvironment; essential requirements for using them as probes for cellular tracking. In this tutorial review, we look at what the current literature can teach us in respect to cell interactions with these nanoparticles, with the perspective of using them as probes for cell labelling. We also examine the findings obtained in pre-clinical studies that expose potential misinterpretation that can occur when using inorganic nanoparticles for in vivo imaging.
Collapse
Affiliation(s)
- Arthur Taylor
- Institute of Translational Medicine, University of Liverpool, Crown Street, L69 3BX, Liverpool, United Kingdom
| | | | | | | | | |
Collapse
|
13
|
Castaneda RT, Khurana A, Khan R, Daldrup-Link HE. Labeling stem cells with ferumoxytol, an FDA-approved iron oxide nanoparticle. J Vis Exp 2011:e3482. [PMID: 22083287 DOI: 10.3791/3482] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
Abstract
Stem cell based therapies offer significant potential for the field of regenerative medicine. However, much remains to be understood regarding the in vivo kinetics of transplanted cells. A non-invasive method to repetitively monitor transplanted stem cells in vivo would allow investigators to directly monitor stem cell transplants and identify successful or unsuccessful engraftment outcomes. A wide range of stem cells continues to be investigated for countless applications. This protocol focuses on 3 different stem cell populations: human embryonic kidney 293 (HEK293) cells, human mesenchymal stem cells (hMSC) and induced pluripotent stem (iPS) cells. HEK 293 cells are derived from human embryonic kidney cells grown in culture with sheared adenovirus 5 DNA. These cells are widely used in research because they are easily cultured, grow quickly and are easily transfected. hMSCs are found in adult marrow. These cells can be replicated as undifferentiated cells while maintaining multipotency or the potential to differentiate into a limited number of cell fates. hMSCs can differentiate to lineages of mesenchymal tissues, including osteoblasts, adipocytes, chondrocytes, tendon, muscle, and marrow stroma. iPS cells are genetically reprogrammed adult cells that have been modified to express genes and factors similar to defining properties of embryonic stem cells. These cells are pluripotent meaning they have the capacity to differentiate into all cell lineages. Both hMSCs and iPS cells have demonstrated tissue regenerative capacity in-vivo. Magnetic resonance (MR) imaging together with the use of superparamagnetic iron oxide (SPIO) nanoparticle cell labels have proven effective for in vivo tracking of stem cells due to the near microscopic anatomical resolution, a longer blood half-life that permits longitudinal imaging and the high sensitivity for cell detection provided by MR imaging of SPIO nanoparticles. In addition, MR imaging with the use of SPIOs is clinically translatable. SPIOs are composed of an iron oxide core with a dextran, carboxydextran or starch surface coat that serves to contain the bioreactive iron core from plasma components. These agents create local magnetic field inhomogeneities that lead to a decreased signal on T2-weighted MR images. Unfortunately, SPIOs are no longer being manufactured. Second generation, ultrasmall SPIOs (USPIO), however, offer a viable alternative. Ferumoxytol (FerahemeTM) is one USPIO composed of a non-stoichiometric magnetite core surrounded by a polyglucose sorbitol carboxymethylether coat. The colloidal, particle size of ferumoxytol is 17-30 nm as determined by light scattering. The molecular weight is 750 kDa, and the relaxivity constant at 2T MRI field is 58.609 mM(-1) sec(-1) strength. Ferumoxytol was recently FDA-approved as an iron supplement for treatment of iron deficiency in patients with renal failure. Our group has applied this agent in an "off label" use for cell labeling applications. Our technique demonstrates efficient labeling of stem cells with ferumoxytol that leads to significant MR signal effects of labeled cells on MR images. This technique may be applied for non-invasive monitoring of stem cell therapies in pre-clinical and clinical settings.
Collapse
|
14
|
Jayapaul J, Hodenius M, Arns S, Lederle W, Lammers T, Comba P, Kiessling F, Gaetjens J. FMN-coated fluorescent iron oxide nanoparticles for RCP-mediated targeting and labeling of metabolically active cancer and endothelial cells. Biomaterials 2011; 32:5863-71. [PMID: 21605902 DOI: 10.1016/j.biomaterials.2011.04.056] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2011] [Accepted: 04/22/2011] [Indexed: 11/16/2022]
Abstract
Riboflavin is an essential vitamin for cellular metabolism and is highly upregulated in metabolically active cells. Consequently, targeting the riboflavin carrier protein (RCP) may be a promising strategy for labeling cancer and activated endothelial cells. Therefore, Ultrasmall SuperParamagnetic Iron Oxide nanoparticles (USPIO) were adsorptively coated with the endogenous RCP ligand flavin mononucleotide (FMN), which renders them target-specific and fluorescent. The core diameter, surface morphology and surface coverage of the resulting FMN-coated USPIO (FLUSPIO) were evaluated using a variety of physico-chemical characterization techniques (TEM, DLS, MRI and fluorescence spectroscopy). The biocompatibility of FLUSPIO was confirmed using three different cell viability assays (Trypan blue staining, 7-AAD staining and TUNEL). In vitro evaluation of FLUSPIO using MRI and fluorescence microscopy demonstrated high labeling efficiency of cancer cells (PC-3, DU-145, LnCap) and activated endothelial cells (HUVEC). Competition experiments (using MRI and ICP-MS) with a 10- and 100-fold excess of free FMN confirmed RCP-specific uptake of the FLUSPIO by PC-3 cells and HUVEC. Hence, RCP-targeting via FMN may be an elegant way to render nanoparticles fluorescent and to increase the labeling efficacy of cancer and activated endothelial cells. This was shown for FLUSPIO, which due to their high T(2)-relaxivity, are favorably suited for MR cell tracking experiments and cancer detection in vivo.
Collapse
Affiliation(s)
- Jabadurai Jayapaul
- Department of Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Irie T, Majima T, Sawaguchi N, Funakoshi T, Nishimura SI, Minami A. Biomechanical and histologic evaluation of tissue engineered ligaments using chitosan and hyaluronan hybrid polymer fibers: A rabbit medial collateral ligament reconstruction model. J Biomed Mater Res A 2011; 97:111-7. [DOI: 10.1002/jbm.a.32938] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2008] [Revised: 12/21/2009] [Accepted: 07/19/2010] [Indexed: 01/13/2023]
|
16
|
Chien LY, Hsiao JK, Hsu SC, Yao M, Lu CW, Liu HM, Chen YC, Yang CS, Huang DM. In vivo magnetic resonance imaging of cell tropism, trafficking mechanism, and therapeutic impact of human mesenchymal stem cells in a murine glioma model. Biomaterials 2011; 32:3275-84. [PMID: 21295344 DOI: 10.1016/j.biomaterials.2011.01.042] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2010] [Accepted: 01/13/2011] [Indexed: 02/07/2023]
Abstract
Stem cells have offered much promise as delivery vehicles for brain tumor therapy, with the development of modalities to track the tumor tropism of stem cells receiving intense focus. Cellular magnetic resonance imaging (MRI) allows serial high-resolution in vivo detection of transplanted stem cells' tropism toward gliomas in the mouse brain once these cells are internally labeled with iron oxide particles, but has been impeded by low labeling efficiencies. In this study, we describe the use of ferucarbotran and protamine (Fer-Pro) complexes for labeling human mesenchymal stem cells (hMSCs) for MRI tracking of glioma tropism in vivo. We found that Fer-Pro was not toxic and was highly efficient for labeling in vitro. Cell labeling with Fer-Pro promoted the migration of hMSCs toward glioma U87MG cells in vitro, which was mediated by stromal-derived factor-1/CXCR4 (SDF-1/CXCR4) signaling. Fer-Pro-labeled hMSCs could migrate specifically toward gliomas in vivo, which was observed with a clinical 1.5-T MRI system. The efficient labeling of Fer-Pro also allowed a tropic mechanism mediated by SDF-1/CXCR4 signaling to be detected by MRI in vivo. Additionally, the potential intrinsic inhibitory effect of hMSCs on glioma progression was estimated simultaneously. This is the first report to have used a clinical MRI modality to simultaneously study the migration, the therapeutic impact on tumors, and above all the trafficking mechanism of bone marrow-derived mesenchymal stem cells from human in a murine glioma xenograft model. The use of Fer-Pro for stem cell labeling may have potential clinical applications in stem cell guided therapy.
Collapse
Affiliation(s)
- Li-Ying Chien
- Center for Nanomedicine Research, National Health Research Institutes, Miaoli 350, Taiwan
| | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Design of iron oxide nanoparticles with different sizes and surface charges for simple and efficient labeling of mesenchymal stem cells. J Control Release 2010; 142:465-73. [DOI: 10.1016/j.jconrel.2009.11.014] [Citation(s) in RCA: 72] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2009] [Revised: 11/04/2009] [Accepted: 11/15/2009] [Indexed: 01/05/2023]
|