1
|
Gietzen C, Kaya K, Janssen JP, Gertz RJ, Terzis R, Huflage H, Grunz JP, Gietzen T, Pennig H, Celik E, Borggrefe J, Persigehl T, Kabbasch C, Weiss K, Goertz L, Pennig L. Highly compressed SENSE accelerated relaxation-enhanced angiography without contrast and triggering (REACT) for fast non-contrast enhanced magnetic resonance angiography of the neck: Clinical evaluation in patients with acute ischemic stroke at 3 tesla. Magn Reson Imaging 2024; 112:27-37. [PMID: 38599503 DOI: 10.1016/j.mri.2024.04.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Revised: 04/06/2024] [Accepted: 04/07/2024] [Indexed: 04/12/2024]
Abstract
BACKGROUND AND PURPOSE Long acquisition times limit the feasibility of established non-contrast-enhanced MRA (non-CE-MRA) techniques. The purpose of this study was to evaluate a highly accelerated flow-independent sequence (Relaxation-Enhanced Angiography without Contrast and Triggering [REACT]) for imaging of the extracranial arteries in acute ischemic stroke (AIS). MATERIALS AND METHODS Compressed SENSE (CS) accelerated (factor 7) 3D isotropic REACT (fixed scan time: 01:22 min, reconstructed voxel size 0.625 × 0.625 × 0.75 mm3) and CE-MRA (CS factor 6, scan time: 1:08 min, reconstructed voxel size 0.5 mm3) were acquired in 76 AIS patients (69.4 ± 14.3 years, 33 females) at 3 Tesla. Two radiologists assessed scans for the presence of internal carotid artery (ICA) stenosis and stated their diagnostic confidence using a 5-point scale (5 = excellent). Vessel quality of cervical arteries as well as the impact of artifacts and image noise were scored on 5-point scales (5 = excellent/none). Apparent signal- and contrast-to-noise ratios (aSNR/aCNR) were measured for the common carotid artery (CCA) and ICA (C1-segment). RESULTS REACT provided a sensitivity of 88.5% and specificity of 100% for clinically relevant (≥50%) ICA stenosis with substantial concordance to CE-MRA regarding stenosis grading (Cohen's kappa 0.778) and similar diagnostic confidence (REACT: mean 4.5 ± 0.4 vs. CE-MRA: 4.5 ± 0.6; P = 0.674). Presence of artifacts (3.6 ± 0.5 vs. 3.5 ± 0.7; P = 0.985) and vessel quality (all segments: 3.6 ± 0.7 vs. 3.8 ± 0.7; P = 0.004) were comparable between both techniques with REACT showing higher scores at the CCA (4.3 ± 0.6 vs. 3.8 ± 0.9; P < 0.001) and CE-MRA at V2- (3.3 ± 0.5 vs. 3.9 ± 0.8; P < 0.001) and V3-segments (3.3 ± 0.5 vs. 4.0 ± 0.8; P < 0.001). For all vessels, REACT showed a lower impact of image noise (3.8 ± 0.6 vs. 3.6 ± 0.7; P = 0.024) while yielding higher aSNR (52.5 ± 15.1 vs. 37.9 ± 12.5; P < 0.001) and aCNR (49.4 ± 15.0 vs. 34.7 ± 12.3; P < 0.001) for all vessels combined. CONCLUSIONS In patients with acute ischemic stroke, highly accelerated REACT provides an accurate detection of ICA stenosis with vessel quality and scan time comparable to CE-MRA.
Collapse
Affiliation(s)
- Carsten Gietzen
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
| | - Kenan Kaya
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Jan Paul Janssen
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Roman Johannes Gertz
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Robert Terzis
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Henner Huflage
- Institute for Diagnostic and Interventional Radiology, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Jan-Peter Grunz
- Institute for Diagnostic and Interventional Radiology, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Thorsten Gietzen
- Department III of Internal Medicine, Heart Center, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Henry Pennig
- Department for Orthopaedic and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne
| | - Erkan Celik
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Jan Borggrefe
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany
| | - Thorsten Persigehl
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Christoph Kabbasch
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | | | - Lukas Goertz
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Lenhard Pennig
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| |
Collapse
|
2
|
Visualisation of lenticulostriate arteries using contrast-enhanced time-of-flight magnetic resonance angiography at 7 Tesla. Sci Rep 2022; 12:20306. [PMID: 36434036 PMCID: PMC9700841 DOI: 10.1038/s41598-022-24832-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Accepted: 11/21/2022] [Indexed: 11/27/2022] Open
Abstract
7 Tesla-field-strength (7 T) Magnetic Resonance Imaging allows the small perforating arteries in the brain to be visualised, and this modality may allow visualisation of the arterial pathology in cerebral small vessel disease. Most studies have used standard Time-of-Flight (ToF) Magnetic Resonance Angiography (MRA). Whether the use of contrast enhancement improves perforating artery visualisation at 7 T remains unclear. In a prospective study, we compared standard ToF MRA with contrast-enhanced (CE) ToF MRA at 7 T for the visualisation of the lenticulostriate arteries (LSAs). Ten patients with symptomatic lacunar stroke were recruited (mean age, SD, 64 ± 9.9 years). Visualisation was assessed using a visual rating scale administered by two independent expert readers and length of the LSAs visible. Visualisation of the LSAs was improved with CE ToF MRA. The mean Visibility and Sharpness Score was higher for CE ToF MRA over standard ToF MRA (2.55 ± 0.64 vs. 1.75 ± 0.68; P = 0.0008). The mean length of LSA visualised was significantly longer with CE ToF MRA compared to standard ToF MRA (24.4 ± 4.5 vs. 21.9 ± 4.0 mm; P = 0.01). CE ToF MRA offers improved visualisation of the LSAs over standard ToF MRA. The addition of contrast may improve the ability to visualise cerebral small vessel disease arterial pathology.
Collapse
|
3
|
Hoyer UCI, Lennartz S, Abdullayev N, Fichter F, Jünger ST, Goertz L, Laukamp KR, Gertz RJ, Grunz JP, Hohmann C, Maintz D, Persigehl T, Kabbasch C, Borggrefe J, Weiss K, Pennig L. Imaging of the extracranial internal carotid artery in acute ischemic stroke: assessment of stenosis, plaques, and image quality using relaxation-enhanced angiography without contrast and triggering (REACT). Quant Imaging Med Surg 2022; 12:3640-3654. [PMID: 35782261 PMCID: PMC9246733 DOI: 10.21037/qims-21-1122] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Accepted: 03/22/2022] [Indexed: 07/24/2023]
Abstract
BACKGROUND In stroke magnetic resonance imaging (MRI), contrast-enhanced magnetic resonance angiography (CE-MRA) is the clinical standard to depict extracranial arteries but native MRA techniques are of increased interest to facilitate clinical practice. The purpose of this study was to assess the detection of extracranial internal carotid artery (ICA) stenosis and plaques as well as the image quality of cervical carotid arteries between a novel flow-independent relaxation-enhanced angiography without contrast and triggering (REACT) sequence and CE-MRA in acute ischemic stroke (AIS). METHODS In this retrospective, single-center study, 105 consecutive patients (65.27±18.74 years, 63 males) were included, who received a standard stroke protocol at 3T in clinical routine including Compressed SENSE (CS) accelerated (factor 4) 3D isotropic REACT (fixed scan time: 02:46 min) and CS accelerated (factor 6) 3D isotropic CE-MRA. Three radiologists independently assessed scans for the presence of extracranial ICA stenosis and plaques (including hyper-/hypointense signal) with concomitant diagnostic confidence using 3-point scales (3= excellent). Vessel quality, artifacts, and image noise of extracranial carotid arteries were subjectively scored on 5-point scales (5= excellent/none). Wilcoxon tests were used for statistical comparison. RESULTS Considering CE-MRA as the standard of reference, REACT provided a sensitivity of 89.8% and specificity of 95.2% for any and of 93.5% and 95.8% for clinically relevant (≥50%) extracranial ICA stenosis and yielded a to CE-MRA comparable diagnostic confidence [mean ± standard deviation (SD), median (interquartile range): 2.8±0.5, 3 (3-3) vs. 2.7±0.5, 3 (2-3), P=0.03]. Using REACT, readers detected more plaques overall (n=57.3 vs. 47.7, P<0.001) and plaques of hyperintense signal (n=12.3 vs. 5.7, P=0.02) with higher diagnostic confidence [2.8±0.5, 3 (3-3) vs. 2.6±0.7, 3 (2-3), P<0.001] than CE-MRA. After analyzing a total of 1,260 segments, the vessel quality of all segments combined [4.61±0.66 vs. 4.58±0.68, 5 (4-5) vs. 5 (4-5), P=0.0299] and artifacts [4.51±0.70 vs. 4.44±0.73, 5 (4-5) vs. 5 (4-5), P>0.05] were comparable between the sequences with REACT showing a lower image noise [4.43±0.67 vs. 4.25±0.71, 5 (4-5) vs. 4 (4-5), P<0.001]. CONCLUSIONS Without the use of gadolinium-based contrast agents or triggering, REACT provides a high sensitivity and specificity for extracranial ICA stenosis and a potential improved depiction of adjacent plaques while yielding to CE-MRA comparable vessel quality in a large patient cohort with AIS.
Collapse
Affiliation(s)
- Ulrike Cornelia Isabel Hoyer
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Simon Lennartz
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Nuran Abdullayev
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Florian Fichter
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Stephanie T. Jünger
- Department of General Neurosurgery, Center for Neurosurgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Lukas Goertz
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
- Department of General Neurosurgery, Center for Neurosurgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Kai Roman Laukamp
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Roman Johannes Gertz
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Jan-Peter Grunz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany
| | - Christopher Hohmann
- Department III of Internal Medicine, Heart Center, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - David Maintz
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Thorsten Persigehl
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Christoph Kabbasch
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Jan Borggrefe
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany
| | | | - Lenhard Pennig
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| |
Collapse
|
4
|
Pennig L, Kabbasch C, Hoyer UCI, Lennartz S, Zopfs D, Goertz L, Laukamp KR, Wagner A, Grunz JP, Doerner J, Persigehl T, Weiss K, Borggrefe J. Relaxation-Enhanced Angiography Without Contrast and Triggering (REACT) for Fast Imaging of Extracranial Arteries in Acute Ischemic Stroke at 3 T. Clin Neuroradiol 2020; 31:815-826. [PMID: 33026511 PMCID: PMC8463375 DOI: 10.1007/s00062-020-00963-6] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Accepted: 09/02/2020] [Indexed: 12/18/2022]
Abstract
Purpose To evaluate a novel flow-independent 3D isotropic REACT sequence compared with CE-MRA for the imaging of extracranial arteries in acute ischemic stroke (AIS). Methods This was a retrospective study of 35 patients who underwent a stroke protocol at 3 T including REACT (fixed scan time: 2:46 min) and CE-MRA of the extracranial arteries. Three radiologists evaluated scans regarding vessel delineation, signal, and contrast and assessed overall image noise and artifacts using 5-point scales (5: excellent delineation/no artifacts). Apparent signal- and contrast-to-noise ratios (aSNR/aCNR) were measured for the common carotid artery (CCA), internal carotid artery (ICA, C1 segment), and vertebral artery (V2 segment). Two radiologists graded the degree of proximal ICA stenosis. Results Compared to REACT, CE-MRA showed better delineation for the CCA and ICA (C1 and C2 segments) (median 5, range 2–5 vs. 4, range 3–5; P < 0.05). For the ICA (C1 and C2 segments), REACT provided a higher signal (5, range 3–5; P < 0.05/4.5, range 3–5; P > 0.05 vs. 4, range 2–5) and contrast (5, range 3–5 vs. 4, range 2–5; P > 0.05) than CE-MRA. The remaining segments of the blood-supplying vessels showed equal medians. There was no significant difference regarding artifacts, whereas REACT provided significantly lower image noise (4, range 3–5 vs. 4 range 2–5; P < 0.05) with a higher aSNR (P < 0.05) and aCNR (P < 0.05) for all vessels combined. For clinically relevant (≥50%) ICA stenosis, REACT achieved a detection sensitivity of 93.75% and a specificity of 100%. Conclusion Given its fast acquisition, comparable image quality to CE-MRA and high sensitivity and specificity for the detection of ICA stenosis, REACT was proven to be a clinically applicable method to assess extracranial arteries in AIS. Electronic supplementary material The online version of this article (10.1007/s00062-020-00963-6) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Lenhard Pennig
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
| | - Christoph Kabbasch
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Ulrike Cornelia Isabel Hoyer
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Simon Lennartz
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
- Harvard Medical School, Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
- Else Kröner Forschungskolleg Clonal Evolution in Cancer, University Hospital Cologne, Cologne, Germany
| | - David Zopfs
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Lukas Goertz
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
- Center for Neurosurgery, Department of General Neurosurgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Kai Roman Laukamp
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Anton Wagner
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Jan-Peter Grunz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany
| | - Jonas Doerner
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Thorsten Persigehl
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | | | - Jan Borggrefe
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany
| |
Collapse
|
5
|
Multiple reader comparison of 2D TOF, 3D TOF, and CEMRA in screening of the carotid bifurcations: Time to reconsider routine contrast use? PLoS One 2020; 15:e0237856. [PMID: 32877415 PMCID: PMC7467222 DOI: 10.1371/journal.pone.0237856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Accepted: 08/04/2020] [Indexed: 11/24/2022] Open
Abstract
Background and purpose MR contrast-enhanced techniques are undergoing increased scrutiny since the FDA applied a warning for gadolinium-based MR contrast agents due to gadolinium deposition within multiple organ systems. While CE-MRA provides excellent image quality, is it required in a screening carotid study? This study compares 2D TOF and 3D TOF MRA vs. CE-MRA in defining carotid stenosis in a large clinical patient population, and with multiple readers with varying experience. Materials and methods 200 consecutive patients had their carotid bifurcations evaluated with 2D TOF, 3D TOF and CE-MRA sequences by 6 board-certified neuroradiologists. Stenosis and quality of examinations were defined for each study. Inter-rater reliability was assessed using two-way random effects intraclass correlation coefficients. Intra-reader reliability was computed via weighted Cohen’s κ. Weighted Cohen’s κ were also computed to assess agreement in stenosis ratings between enhanced images and unenhanced images. Results Agreement between unenhanced and enhanced ratings was substantial with a pooled weighted κ of 0.733 (0.628–0.811). For 5 of the 6 readers, the combination of unenhanced 2D TOF and 3D TOF showed better agreement with contrast-enhanced than either 2D TOF or 3D TOF alone. Intra-reader reliability was substantial. Conclusions The combination of 2D TOF and 3D TOF MRA showed substantial agreement with CE-MRA regarding degree of carotid stenosis in this large outpatient population across multiple readers of varying experience. Given the scrutiny that GBCA are undergoing due to concerns regarding CNS and soft tissue deposition, it seems prudent to reserve CE-MRA for cases which are not satisfactorily answered by the nonenhanced study or other noninvasive examinations.
Collapse
|
6
|
Koktzoglou I, Huang R, Ong AL, Aouad PJ, Aherne EA, Edelman RR. Feasibility of a sub-3-minute imaging strategy for ungated quiescent interval slice-selective MRA of the extracranial carotid arteries using radial k-space sampling and deep learning-based image processing. Magn Reson Med 2020; 84:825-837. [PMID: 31975432 DOI: 10.1002/mrm.28179] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Revised: 12/09/2019] [Accepted: 12/30/2019] [Indexed: 12/15/2022]
Abstract
PURPOSE To develop and test the feasibility of a sub-3-minute imaging strategy for non-contrast evaluation of the extracranial carotid arteries using ungated quiescent interval slice-selective (QISS) MRA, combining single-shot radial sampling with deep neural network-based image processing to optimize image quality. METHODS The extracranial carotid arteries of 12 human subjects were imaged at 3 T using ungated QISS MRA. In 7 healthy volunteers, the effects of radial and Cartesian k-space sampling, single-shot and multishot image acquisition (1.1-3.3 seconds/slice, 141-423 seconds/volume), and deep learning-based image processing were evaluated using segmental image quality scoring, arterial temporal SNR, arterial-to-background contrast and apparent contrast-to-noise ratio, and structural similarity index. Comparison of deep learning-based image processing was made with block matching and 3D filtering denoising. RESULTS Compared with Cartesian sampling, radial k-space sampling increased arterial temporal SNR 107% (P < .001) and improved image quality during 1-shot imaging (P < .05). The carotid arteries were depicted with similar image quality on the rapid 1-shot and much lengthier 3-shot radial QISS protocols (P = not significant), which was corroborated in patient studies. Deep learning-based image processing outperformed block matching and 3D filtering denoising in terms of structural similarity index (P < .001). Compared with original QISS source images, deep learning image processing provided 24% and 195% increases in arterial-to-background contrast (P < .001) and apparent contrast-to-noise ratio (P < .001), and provided source images that were preferred by radiologists (P < .001). CONCLUSION Rapid, sub-3-minute evaluation of the extracranial carotid arteries is feasible with ungated single-shot radial QISS, and benefits from the use of deep learning-based image processing to enhance source image quality.
Collapse
Affiliation(s)
- Ioannis Koktzoglou
- Department of Radiology, NorthShore University HealthSystem, Evanston, Illinois.,Pritzker School of Medicine, University of Chicago, Chicago, Illinois
| | - Rong Huang
- Department of Radiology, NorthShore University HealthSystem, Evanston, Illinois
| | - Archie L Ong
- Pritzker School of Medicine, University of Chicago, Chicago, Illinois.,Department of Neurology, NorthShore University HealthSystem, Evanston, Illinois
| | - Pascale J Aouad
- Department of Radiology, NorthShore University HealthSystem, Evanston, Illinois.,Northwestern University Feinberg School of Medicine, Chicago, Illinois
| | - Emily A Aherne
- Department of Radiology, NorthShore University HealthSystem, Evanston, Illinois.,Northwestern University Feinberg School of Medicine, Chicago, Illinois
| | - Robert R Edelman
- Department of Radiology, NorthShore University HealthSystem, Evanston, Illinois.,Northwestern University Feinberg School of Medicine, Chicago, Illinois
| |
Collapse
|
7
|
Peters S, Huhndorf M, Jensen-Kondering U, Larsen N, Koktzoglou I, Edelman RR, Graessner J, Both M, Jansen O, Salehi Ravesh M. Non-Contrast-Enhanced Carotid MRA: Clinical Evaluation of a Novel Ungated Radial Quiescent-Interval Slice-Selective MRA at 1.5T. AJNR Am J Neuroradiol 2019; 40:1529-1537. [PMID: 31395666 DOI: 10.3174/ajnr.a6171] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2019] [Accepted: 07/04/2019] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Non-contrast-enhanced MRA techniques have experienced a renaissance due to the known correlation between the use of gadolinium-based contrast agents and the development of nephrogenic systemic fibrosis and the deposition of gadolinium in some brain regions. The purpose of this study was to assess the diagnostic performance of ungated non-contrast-enhanced radial quiescent-interval slice-selective MRA of the extracranial supra-aortic arteries in comparison with conventional contrast-enhanced MRA in patients with clinical suspicion of carotid stenosis. MATERIALS AND METHODS In this prospective study, both MRA pulse sequences were performed in 31 consecutive patients (median age, 68.8 years; 19 men). For the evaluation, the cervical arterial system was divided into 35 segments (right and left side). Three blinded reviewers separately evaluated these segments. An ordinal scoring system was used to assess the image quality of arterial segments and the stenosis grading of carotid arteries. RESULTS Overall venous contamination in quiescent-interval slice-selective MRA was rated as "none" by all readers in 84.9% of cases and in 8.1% of cases in contrast-enhanced MRA (P < .0001). The visualization quality of arterial segments was considered good to excellent in 40.2% for the quiescent-interval slice-selective MRA and in 52.2% for the contrast-enhanced MRA (P < .0001). The diagnostic accuracy of ungated quiescent-interval slice-selective MRA concerning the stenosis grading showed a total sensitivity and specificity of 85.7% and 90.0%, respectively. CONCLUSIONS Ungated quiescent-interval slice-selective MRA can be used clinically as an alternative to contrast-enhanced MRA without a significantly different image quality or diagnostic accuracy for the detection of carotid stenosis at 1.5T.
Collapse
Affiliation(s)
- S Peters
- From the Department of Radiology and Neuroradiology (S.P., M.H., U.J.-K., N.L., M.B., O.J., M.S.R.), University Medical Center Schleswig-Holstein, Kiel University, Kiel, Germany
| | - M Huhndorf
- From the Department of Radiology and Neuroradiology (S.P., M.H., U.J.-K., N.L., M.B., O.J., M.S.R.), University Medical Center Schleswig-Holstein, Kiel University, Kiel, Germany
| | - U Jensen-Kondering
- From the Department of Radiology and Neuroradiology (S.P., M.H., U.J.-K., N.L., M.B., O.J., M.S.R.), University Medical Center Schleswig-Holstein, Kiel University, Kiel, Germany
| | - N Larsen
- From the Department of Radiology and Neuroradiology (S.P., M.H., U.J.-K., N.L., M.B., O.J., M.S.R.), University Medical Center Schleswig-Holstein, Kiel University, Kiel, Germany
| | - I Koktzoglou
- Department of Radiology (I.K., R.R.E.), NorthShore University Health System, Evanston, Illinois.,University of Chicago Pritzker School of Medicine (I.K.), Chicago, Illinois
| | - R R Edelman
- Department of Radiology (I.K., R.R.E.), NorthShore University Health System, Evanston, Illinois.,Northwestern University Feinberg School of Medicine (R.R.E.), Chicago, Illinois
| | | | - M Both
- From the Department of Radiology and Neuroradiology (S.P., M.H., U.J.-K., N.L., M.B., O.J., M.S.R.), University Medical Center Schleswig-Holstein, Kiel University, Kiel, Germany
| | - O Jansen
- From the Department of Radiology and Neuroradiology (S.P., M.H., U.J.-K., N.L., M.B., O.J., M.S.R.), University Medical Center Schleswig-Holstein, Kiel University, Kiel, Germany
| | - M Salehi Ravesh
- From the Department of Radiology and Neuroradiology (S.P., M.H., U.J.-K., N.L., M.B., O.J., M.S.R.), University Medical Center Schleswig-Holstein, Kiel University, Kiel, Germany
| |
Collapse
|
8
|
Liu H, Sun J, Hippe DS, Wu W, Chu B, Balu N, Hatsukami T, Yuan C. Improved carotid lumen delineation on non-contrast MR angiography using SNAP (Simultaneous Non-Contrast Angiography and Intraplaque Hemorrhage) imaging. Magn Reson Imaging 2019; 62:87-93. [PMID: 31247251 DOI: 10.1016/j.mri.2019.06.012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Revised: 06/20/2019] [Accepted: 06/22/2019] [Indexed: 01/02/2023]
Abstract
PURPOSE Simultaneous Non-Contrast Angiography and Intraplaque Hemorrhage (SNAP) was developed for improved imaging of intraplaque hemorrhage (IPH). Its signal polarity also allows for non-contrast time-of-flight MR angiography (TOF). This study sought to compare SNAP and TOF in delineating carotid lumen using contrast-enhanced MRA (CE-MRA) as the reference standard. MATERIALS AND METHODS Two hundred and eighty-nine matched slices from 15 arteries among 11 subjects (9 males and 2 females, mean age of 72.1 ± 8.6 years) with luminal stenosis on CE-MRA were studied. Cross-sectional slices centered around the carotid bifurcation were matched between the three MRA techniques (SNAP, TOF, and CE-MRA) and classified as slices with or without plaque (focal wall thickness ≥ 1.5 mm) by additional black-blood vessel wall MRI. Lumen area was measured using a Sobel gradient map for TOF and CE-MRA (magnitude images) and a polarity map for SNAP. Agreement between techniques for measuring lumen area and percent stenosis was evaluated using intraclass correlation coefficient (ICC) and paired t-test. RESULTS Among the 289 matched slices, SNAP showed a higher agreement with CE-MRA than TOF for measuring lumen area (ICC: 0.93 vs. 0.83; p = 0.03). Agreement with CE-MRA was high for both SNAP and TOF in slices without plaque (ICC: 0.91 vs. 0.89; p > 0.05) but favored SNAP over TOF in slices with plaque (ICC: 0.93 vs. 0.80; p = 0.02). CONCLUSION SNAP, assisted by signal polarity information, demonstrated a higher agreement with CE-MRA in delineating carotid lumen compared to TOF, particularly in slices with plaque where flow conditions may be more complex.
Collapse
Affiliation(s)
- Haining Liu
- Department of Radiology, University of Washington, Seattle, WA 98109, United States.
| | - Jie Sun
- Department of Radiology, University of Washington, Seattle, WA 98109, United States
| | - Daniel S Hippe
- Department of Radiology, University of Washington, Seattle, WA 98109, United States
| | - Wei Wu
- Department of Radiology, University of Washington, Seattle, WA 98109, United States; Tongji Hospital, Tongji Medical College Affiliated to Huazhong University of Science and Technology, Department of Radiology, 1095 Jiefang Avenue, Wuhan 430000, China
| | - Baocheng Chu
- Department of Radiology, University of Washington, Seattle, WA 98109, United States
| | - Niranjan Balu
- Department of Radiology, University of Washington, Seattle, WA 98109, United States
| | - Thomas Hatsukami
- Department of Surgery, University of Washington, Seattle, WA 98109, United States
| | - Chun Yuan
- Department of Radiology, University of Washington, Seattle, WA 98109, United States; Department of Bioengineering, University of Washington, Seattle, WA 98109, United States; Department of Bioengineering, Tsinghua University, Beijing 100084, China
| |
Collapse
|
9
|
Koktzoglou I, Aherne EA, Walker MT, Meyer JR, Edelman RR. Ungated nonenhanced radial quiescent interval slice-selective (QISS) magnetic resonance angiography of the neck: Evaluation of image quality. J Magn Reson Imaging 2019; 50:1798-1807. [PMID: 31077477 DOI: 10.1002/jmri.26781] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2019] [Revised: 04/24/2019] [Accepted: 04/25/2019] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND Standard-of-care time-of-flight (TOF) techniques for nonenhanced magnetic resonance angiography (NEMRA) of the carotid bifurcation and other cervical arteries often provide nondiagnostic image quality due to motion and flow artifacts. PURPOSE To perform an initial evaluation of an ungated radial quiescent-interval slice-selective (QISS) technique for NEMRA of the neck, in comparison with 2D TOF and contrast-enhanced magnetic resonance angiography (CEMRA). STUDY TYPE Retrospective. POPULATION Sixty patients referred for neck MR angiography. FIELD STRENGTH/SEQUENCE Ungated radial QISS at 3T. ASSESSMENT Three radiologists scored image quality of 18 arterial segments using a 4-point scale (1, nondiagnostic; 2, fair; 3, good; 4, excellent), and two radiologists graded proximal internal carotid stenosis using five categories (<50%, 50-69%, 70-99%, occlusion, nondiagnostic). STATISTICAL TESTS Friedman tests with post-hoc Wilcoxon signed-rank tests; unweighted Gwet's AC1 statistic; tests for equality of proportions. RESULTS Ungated radial QISS provided image quality that significantly exceeded 2D TOF (mean scores of 2.7 vs. 2.0, 2.7 vs. 2.2, and 2.9 vs. 2.3; P < 0.001, all comparisons), while CEMRA provided the best image quality (mean scores of 3.6, 3.7, and 3.5 for the three reviewers). Interrater agreement of image quality scores was substantial for CEMRA (AC1 = 0.70, P < 0.001), and moderate for QISS (AC1 = 0.43, P < 0.001) and TOF (AC1 = 0.41, P < 0.001). Compared with TOF, QISS NEMRA provided a significantly higher percentage of diagnostic segments for all three reviewers (91.0% vs. 71.7%, 93.5% vs. 72.9%, 95.5% vs. 85.2%; P < 0.0001) and demonstrated better agreement with CEMRA for grading of proximal internal carotid stenosis (AC1 = 0.94 vs. 0.73 for reviewer 1, P < 0.05; AC1 = 0.89 vs. 0.68 for reviewer 2, P < 0.05). DATA CONCLUSION In this initial study, ungated radial QISS significantly outperformed 2D TOF for the evaluation of the neck arteries, with overall better image quality and more diagnostic arterial segments, and improved agreement with CEMRA for grading stenosis of the proximal internal carotid artery. LEVEL OF EVIDENCE 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;50:1798-1807.
Collapse
Affiliation(s)
- Ioannis Koktzoglou
- Department of Radiology, NorthShore University HealthSystem, Evanston, Illinois, USA.,University of Chicago Pritzker School of Medicine, Chicago, Illinois, USA
| | - Emily A Aherne
- Department of Radiology, NorthShore University HealthSystem, Evanston, Illinois, USA.,Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Matthew T Walker
- Department of Radiology, NorthShore University HealthSystem, Evanston, Illinois, USA.,University of Chicago Pritzker School of Medicine, Chicago, Illinois, USA
| | - Joel R Meyer
- Department of Radiology, NorthShore University HealthSystem, Evanston, Illinois, USA.,University of Chicago Pritzker School of Medicine, Chicago, Illinois, USA
| | - Robert R Edelman
- Department of Radiology, NorthShore University HealthSystem, Evanston, Illinois, USA.,Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| |
Collapse
|
10
|
Koktzoglou I, Walker MT, Meyer JR, Murphy IG, Edelman RR. Nonenhanced hybridized arterial spin labeled magnetic resonance angiography of the extracranial carotid arteries using a fast low angle shot readout at 3 Tesla. J Cardiovasc Magn Reson 2016; 18:18. [PMID: 27067840 PMCID: PMC4828773 DOI: 10.1186/s12968-016-0238-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2015] [Accepted: 03/24/2016] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND To evaluate ungated nonenhanced hybridized arterial spin labeling (hASL) magnetic resonance angiography (MRA) of the extracranial carotid arteries using a fast low angle shot (FLASH) readout at 3 Tesla. METHODS In this retrospective, institutional review board-approved and HIPAA-compliant study, we evaluated the image quality (4-point scale) of nonenhanced hASL MRA using a FLASH readout with respect to contrast-enhanced MRA (CEMRA) in 37 patients presenting with neurologic symptoms. Two certified neuroradiologists independently evaluated 407 arterial segments (11 per patient) for image quality. The presence of vascular pathology was determined by consensus reading. Gwet's AC1 was used to assess inter-rater agreement in image quality scores, and image quality scores were correlated with age and body mass index. Objective measurements of arterial lumen area and sharpness in the carotid arteries were compared to values obtained with CEMRA. Comparisons were also made with conventional nonenhanced 2D time-of-flight (TOF) MRA. RESULTS CEMRA provided the best image quality, while nonenhanced hASL FLASH MRA provided image quality that exceeded 2D TOF at the carotid bifurcation and in the internal and external carotid arteries. All nine vascular abnormalities of the carotid and intracranial arteries detected by CEMRA were depicted with hASL MRA, with no false positives. Inter-rater agreement of image quality scores was highest for CEMRA (AC1 = 0.87), followed by hASL (AC1 = 0.61) and TOF (AC1 = 0.43) (P < 0.001, all comparisons). With respect to CEMRA, agreement in cross-sectional lumen area was significantly better with hASL than TOF in the common carotid artery (intraclass correlation (ICC) = 0.90 versus 0.66; P < 0.05) and at the carotid bifurcation (ICC = 0.87 versus 0.54; P < 0.05). Nonenhanced hASL MRA provided superior arterial sharpness with respect to CEMRA and 2D TOF (P < 0.001). CONCLUSION Although inferior to CEMRA in terms of image quality and inter-rater agreement, hASL FLASH MRA offers an alternative to 2D TOF for the nonenhanced evaluation of the extracranial carotid arteries at 3 Tesla. Compared with 2D TOF, nonenhanced hASL FLASH MRA provides improved quantification of arterial cross-sectional area, vessel sharpness, inter-rater agreement and image quality.
Collapse
Affiliation(s)
- Ioannis Koktzoglou
- />Department of Radiology, NorthShore University HealthSystem, Evanston, USA
- />University of Chicago Pritzker School of Medicine, Chicago, USA
| | - Matthew T. Walker
- />Department of Radiology, NorthShore University HealthSystem, Evanston, USA
- />University of Chicago Pritzker School of Medicine, Chicago, USA
| | - Joel R. Meyer
- />Department of Radiology, NorthShore University HealthSystem, Evanston, USA
- />University of Chicago Pritzker School of Medicine, Chicago, USA
| | - Ian G. Murphy
- />Department of Radiology, NorthShore University HealthSystem, Evanston, USA
- />Northwestern University Feinberg School of Medicine, Chicago, USA
| | - Robert R. Edelman
- />Department of Radiology, NorthShore University HealthSystem, Evanston, USA
- />Northwestern University Feinberg School of Medicine, Chicago, USA
| |
Collapse
|
11
|
Kramer M, Ellmann S, Allmendinger T, Eller A, Kammerer F, May MS, Baigger JF, Uder M, Lell MM. Computed Tomography Angiography of Carotid Arteries and Vertebrobasilar System: A Simulation Study for Radiation Dose Reduction. Medicine (Baltimore) 2015; 94:e1058. [PMID: 26131822 PMCID: PMC4504529 DOI: 10.1097/md.0000000000001058] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
Computed tomography angiography (CTA) of carotid arteries and vertebrobasilar system is a standardized procedure with excellent image quality, but radiation exposure remains a matter of concern. The aim of this study is to examine to what extent radiation dose can be lowered in relation to a standard protocol by simulating examinations with lower tube currents applying a dedicated software.Lower tube current was simulated by a dedicated noise insertion and reconstruction software (ReconCT). In a phantom study, true scans were performed with different dose protocols and compared to the results of simulated dose reductions of the same degree, respectively. In a patient study, 30 CTAs of supra-aortic vessels were reconstructed at a level of 100%, 75%, 50%, and 25% of the initial dose. Objective and subjective image analyses were performed.No significant noise differences between true scans and simulated scans of mimicked contrasted vessels were found. In the patient study, the quality scores of the 4 dose groups differed statistically significant; this difference vanished for the comparison of the 100% and 75% datasets after dichotomization into the categories of diagnostic and nondiagnostic image quality (P = .50).This study suggests an easy-to-implement method of simulating CTAs of carotid arteries and vertebrobasilar system with lower tube current for dose reduction by artificially adding noise to the original raw data. Lowering the radiation dose in a moderate extent to 75% of the original dose levels does not significantly alter the diagnostic image quality.
Collapse
|
12
|
Le Bras A, Raoult H, Ferré JC, Ronzière T, Gauvrit JY. Optimal MRI sequence for identifying occlusion location in acute stroke: which value of time-resolved contrast-enhanced MRA? AJNR Am J Neuroradiol 2015; 36:1081-8. [PMID: 25767186 DOI: 10.3174/ajnr.a4264] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2014] [Accepted: 12/21/2014] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Identifying occlusion location is crucial for determining the optimal therapeutic strategy during the acute phase of ischemic stroke. The purpose of this study was to assess the diagnostic efficacy of MR imaging, including conventional sequences plus time-resolved contrast-enhanced MRA in comparison with DSA for identifying arterial occlusion location. MATERIALS AND METHODS Thirty-two patients with 34 occlusion levels referred for thrombectomy during acute cerebral stroke events were consecutively included from August 2010 to December 2012. Before thrombectomy, we performed 3T MR imaging, including conventional 3D-TOF and gradient-echo T2 sequences, along with time-resolved contrast-enhanced MRA of the extra- and intracranial arteries. The 3D-TOF, gradient-echo T2, and time-resolved contrast-enhanced MRA results were consensually assessed by 2 neuroradiologists and compared with prethrombectomy DSA results in terms of occlusion location. The Wilcoxon test was used for statistical analysis to compare MR imaging sequences with DSA, and the κ coefficient was used to determine intermodality agreement. RESULTS The occlusion level on the 3D-TOF and gradient-echo T2 images differed significantly from that of DSA (P < .001 and P = .002, respectively), while no significant difference was observed between DSA and time-resolved contrast-enhanced MRA (P = .125). κ coefficients for intermodality agreement with DSA (95% CI, percentage agreement) were 0.43 (0.3%-0.6; 62%), 0.32 (0.2%-0.5; 56%), and 0.81 (0.6%-1.0; 88%) for 3D-TOF, gradient-echo T2, and time-resolved contrast-enhanced MRA, respectively. CONCLUSIONS The time-resolved contrast-enhanced MRA sequence proved reliable for identifying occlusion location in acute stroke with performance superior to that of 3D-TOF and gradient-echo T2 sequences.
Collapse
Affiliation(s)
- A Le Bras
- From the Departments of Neuroradiology (A.L.B., H.R., J.-C.F., J.-Y.G.)
| | - H Raoult
- From the Departments of Neuroradiology (A.L.B., H.R., J.-C.F., J.-Y.G.) Unité VISAGE U746 INSERM-INRIA, IRISA UMR CNRS 6074 (H.R., J.-C.F., J.-Y.G.), University of Rennes, Rennes, France
| | - J-C Ferré
- From the Departments of Neuroradiology (A.L.B., H.R., J.-C.F., J.-Y.G.) Unité VISAGE U746 INSERM-INRIA, IRISA UMR CNRS 6074 (H.R., J.-C.F., J.-Y.G.), University of Rennes, Rennes, France
| | - T Ronzière
- Neurology (T.R.), Centre Hospitalier Universitaire Rennes, Rennes, France
| | - J-Y Gauvrit
- From the Departments of Neuroradiology (A.L.B., H.R., J.-C.F., J.-Y.G.) Unité VISAGE U746 INSERM-INRIA, IRISA UMR CNRS 6074 (H.R., J.-C.F., J.-Y.G.), University of Rennes, Rennes, France
| |
Collapse
|
13
|
Suttmeyer B, Teichgräber U, Thomas A, Rathke H, Albrecht L, Jonczyk M, Verba M, Güttler F, Schnackenburg B, Hamm B, de Bucourt M. Non-invasive ECG-triggered 2D TOF MR angiography of the pelvic and leg arteries in an open 1.0-tesla high-field MRI system in comparison to conventional DSA. ACTA ACUST UNITED AC 2015; 59:29-37. [PMID: 24334421 DOI: 10.1515/bmt-2013-0113] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2013] [Accepted: 11/20/2013] [Indexed: 11/15/2022]
Abstract
OBJECTIVES A non-contrast-enhanced 2D time-of-flight magnetic resonance angiography (TOF-MRA) protocol was compared with the gold standard of planar digital subtraction angiography (DSA) by calculating correlations of vessel diameters. METHODS A total of 1134 vascular diameters in 81 corresponding sites were prospectively measured by TOF-MRA and DSA in seven patients (four women, three men; mean age, 68 years). For a total of 162 vascular segments per patient, 81 Spearman's ρ correlation coefficients were calculated, consolidated to 41 due to consideration of symmetry (right/left), and assessed by correlation quality. RESULTS In the 41 consolidated segments, correlations were good, very good, and excellent in 25 segments (n=10>0.5, n=4>0.7, and n=11>0.8), moderate to poor in seven segments (n=4>0.3 and 0<n=3≤0.3), without in two, inverse in three, and nonmeasurable in four segments. Correlations were best for the main arteries above the knee, and these arteries were most consistently visualized. CONCLUSION The TOF-MRA protocol presented here can be performed in an open 1.0-T MRI system in 60-90 min. Visualization is degraded when the target artery leaves the plane orthogonal to the imaging plane (1) or signal yield is poor due to small caliber (2).
Collapse
|
14
|
Lv P, Lin J, Guo D, Liu H, Tang X, Fu C, Hu J. Detection of carotid artery stenosis: a comparison between 2 unenhanced MRAs and dual-source CTA. AJNR Am J Neuroradiol 2014; 35:2360-5. [PMID: 25104291 DOI: 10.3174/ajnr.a4073] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
BACKGROUND AND PURPOSE Dual-source CTA and black-blood MRA are recently developed techniques for evaluating carotid stenosis. The purpose of this study was to compare dual-source CTA with black-blood MRA and conventional TOF MRA in both detecting carotid stenosis by using DSA as a reference standard and demonstrating plaque morphology. MATERIALS AND METHODS Thirty patients with suspected carotid artery stenosis underwent unenhanced MRA by using black-blood and TOF MRA and dual-source CTA. Source images from unenhanced MRAs and dual-source CTA were reconstructed with MIP or curved planar reconstruction. The degree of carotid artery stenosis was measured, and plaque surface morphology at the stenosis was analyzed and compared among different techniques. RESULTS Good correlation was observed for measuring the degree of carotid stenosis among dual-source CTA, black-blood MRA, TOF MRA, and DSA. Sensitivity and specificity for detecting severe stenosis were 100% and 97% with dual-source CTA, 100% and 95% with black-blood MRA, and 79% and 95% with TOF MRA. None of the 3 technologies resulted in stenosis of <50% being overestimated. Plaque surface irregularity or ulceration was more frequently detected with dual-source CTA and black-blood MRA than with TOF MRA and DSA. CONCLUSIONS This preliminary study shows that black-blood MRA is a promising technique, comparable with dual-source CTA and DSA, but better than TOF MRA, in the evaluation of carotid stenosis. Unlike dual-source CTA, black-blood MRA requires no intravenous contrast or radiation.
Collapse
Affiliation(s)
- P Lv
- From the Department of Radiology (P.L., J.L., H.L.), Zhongshan Hospital, Shanghai Medical College of Fudan University and Shanghai Institute of Medical Imaging, Shanghai, China
| | - J Lin
- From the Department of Radiology (P.L., J.L., H.L.), Zhongshan Hospital, Shanghai Medical College of Fudan University and Shanghai Institute of Medical Imaging, Shanghai, China
| | - D Guo
- Department of Vascular Surgery (D.G., X.T.), Zhongshan Hospital, Fudan University and Institute of Vascular Surgery, Shanghai, China
| | - H Liu
- From the Department of Radiology (P.L., J.L., H.L.), Zhongshan Hospital, Shanghai Medical College of Fudan University and Shanghai Institute of Medical Imaging, Shanghai, China
| | - X Tang
- Department of Vascular Surgery (D.G., X.T.), Zhongshan Hospital, Fudan University and Institute of Vascular Surgery, Shanghai, China
| | - C Fu
- Siemens Shenzhen Magnetic Resonance (C.F.), Shenzhen, China
| | - J Hu
- Department of Cardiology (J.H.), Zhongshan Hospital, Fudan University, Shanghai, China
| |
Collapse
|
15
|
Koktzoglou I, Meyer JR, Ankenbrandt WJ, Giri S, Piccini D, Zenge MO, Flanagan O, Desai T, Gupta N, Edelman RR. Nonenhanced arterial spin labeled carotid MR angiography using three-dimensional radial balanced steady-state free precession imaging. J Magn Reson Imaging 2014; 41:1150-6. [PMID: 24737420 DOI: 10.1002/jmri.24640] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2014] [Accepted: 03/26/2014] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To optimize and preliminarily evaluate a three-dimensional (3D) radial balanced steady-state free precession (bSSFP) arterial spin labeled (ASL) sequence for nonenhanced MR angiography (MRA) of the extracranial carotid arteries. MATERIALS AND METHODS The carotid arteries of 13 healthy subjects and 2 patients were imaged on a 1.5 Tesla MRI system using an undersampled 3D radial bSSFP sequence providing a scan time of ∼4 min and 1 mm(3) isotropic resolution. A hybridized scheme that combined pseudocontinuous and pulsed ASL was used to maximize arterial coverage. The impact of a post label delay period, the sequence repetition time, and radiofrequency (RF) energy configuration of pseudocontinuous labeling on the display of the carotid arteries was assessed with contrast-to-noise ratio (CNR) measurements. Faster, higher undersampled 2 and 1 min scans were tested. RESULTS Using hybridized ASL MRA and a 3D radial bSSFP trajectory, arterial CNR was maximized with a post label delay of 0.2 s, repetition times ≥ 2.5 s (P < 0.05), and by eliminating RF energy during the pseudocontinuous control phase (P < 0.001). With higher levels of undersampling, the carotid arteries were displayed in ≤ 2 min. CONCLUSION Nonenhanced MRA using hybridized ASL with a 3D radial bSSFP trajectory can display long lengths of the carotid arteries with 1 mm(3) isotropic resolution.
Collapse
Affiliation(s)
- Ioannis Koktzoglou
- Department of Radiology, NorthShore University HealthSystem, Evanston, Illinois, USA; The University of Chicago Pritzker School of Medicine, Chicago, Illinois, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Ferré JC, Raoult H, Breil S, Carsin-Nicol B, Ronzière T, Gauvrit JY. Supra-aortic arteries: three-dimensional time-resolved k-t BLAST contrast-enhanced MRA using a nondedicated body coil at 3 tesla in acute ischemic stroke. J Magn Reson Imaging 2013; 40:1056-63. [PMID: 24222649 DOI: 10.1002/jmri.24466] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2013] [Accepted: 09/14/2013] [Indexed: 11/10/2022] Open
Abstract
PURPOSE To assess the image quality and diagnostic performance achieved by using supra-aortic 3D-TR-CE-k-t BLAST MRA and a nondedicated body coil as compared with conventional CE-MRA in patients with acute ischemic stroke. MATERIALS AND METHODS In this prospective study, 36 consecutive patients with a suspected acute ischemic stroke underwent both k-t BLAST MRA and conventional CE-MRA. Image quality was assessed using visual and quantitative criteria and the techniques were compared. Both techniques were compared for degree of visual and quantitative measurement of carotid stenosis. RESULTS Delineation of vessel lumen and overall diagnostic confidence were significantly better with CE-MRA, respectively 3.4 ± 0.5 and 3.3 ± 0.6 (mean score ± SD), than with k-t BLAST MRA, respectively 2.8 ± 0.4 and 2.9 ± 0.5 (P < 0.02). SNR and CNR were significantly higher for k-t BLAST MRA, respectively 33.5 ± 19.3 and 27.9 ± 19.3, than for CE-MRA, respectively 25.7 ± 10 and 20.4 ± 8.4 (P < 0.03). Intertechnique agreement was good for carotid stenosis characterization (κ = .763). For the 14 relevant stenosis, stenosis measurements were highly correlated between techniques (0.96; P < 0.0001). The Bland-Altman plot showed a low bias in assessment of the degree of stenosis (mean bias 2.1% ± 7.7). CONCLUSION k-t BLAST MRA using a nondedicated coil offering and dynamic information was a effective diagnostic tool for detection and characterization of carotid stenosis.
Collapse
Affiliation(s)
- Jean-Christophe Ferré
- CHU Rennes, Department of Neuroradiology, University Hospital of Rennes, Rennes, France
| | | | | | | | | | | |
Collapse
|
17
|
Non-ECG-gated unenhanced MRA of the carotids: optimization and clinical feasibility. Eur Radiol 2013; 23:3020-8. [PMID: 23783783 DOI: 10.1007/s00330-013-2931-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2013] [Revised: 05/06/2013] [Accepted: 05/20/2013] [Indexed: 10/26/2022]
Abstract
OBJECTIVES To optimise and assess the clinical feasibility of a carotid non-ECG-gated unenhanced MRA sequence. METHODS Sixteen healthy volunteers and 11 patients presenting with internal carotid artery (ICA) disease underwent large field-of-view balanced steady-state free precession (bSSFP) unenhanced MRA at 3T. Sampling schemes acquiring the k-space centre either early (kCE) or late (kCL) in the acquisition window were evaluated. Signal and image quality was scored in comparison to ECG-gated kCE unenhanced MRA and TOF. For patients, computed tomography angiography was used as the reference. RESULTS In volunteers, kCE sampling yielded higher image quality than kCL and TOF, with fewer flow artefacts and improved signal homogeneity. kCE unenhanced MRA image quality was higher without ECG-gating. Arterial signal and artery/vein contrast were higher with both bSSFP sampling schemes than with TOF. The kCE sequence allowed correct quantification of ten significant stenoses, and it facilitated the identification of an infrapetrous dysplasia, which was outside of the TOF imaging coverage. CONCLUSIONS Non-ECG-gated bSSFP carotid imaging offers high-quality images and is a promising sequence for carotid disease diagnosis in a short acquisition time with high spatial resolution and a large field of view. KEY POINTS • Non-ECG-gated unenhanced bSSFP MRA offers high-quality imaging of the carotid arteries. • Sequences using early acquisition of the k-space centre achieve higher image quality. • Non-ECG-gated unenhanced bSSFP MRA allows quantification of significant carotid stenosis. • Short MR acquisition times and ungated sequences are helpful in clinical practice. • High 3D spatial resolution and a large field of view improve diagnostic performance.
Collapse
|
18
|
Coppenrath EM, Lummel N, Linn J, Lenz O, Habs M, Nikolaou K, Reiser MF, Dichgans M, Pfefferkorn T, Saam T. Time-of-flight angiography: a viable alternative to contrast-enhanced MR angiography and fat-suppressed T1w images for the diagnosis of cervical artery dissection? Eur Radiol 2013; 23:2784-92. [DOI: 10.1007/s00330-013-2891-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2012] [Revised: 03/29/2013] [Accepted: 04/03/2013] [Indexed: 11/29/2022]
|
19
|
Morelli JN, Gerdes CM, Schmitt P, Ai T, Saettele MR, Runge VM, Attenberger UI. Technical considerations in MR angiography: An image-based guide. J Magn Reson Imaging 2013; 37:1326-41. [DOI: 10.1002/jmri.24174] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2012] [Accepted: 03/20/2013] [Indexed: 11/09/2022] Open
|
20
|
Kramer JH, Arnoldi E, François CJ, Wentland AL, Nikolaou K, Wintersperger BJ, Grist TM. Dynamic and static magnetic resonance angiography of the supra-aortic vessels at 3.0 T: intraindividual comparison of gadobutrol, gadobenate dimeglumine, and gadoterate meglumine at equimolar dose. Invest Radiol 2013; 48:121-8. [PMID: 23211552 PMCID: PMC3818529 DOI: 10.1097/rli.0b013e31827752b4] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE The purpose of this study was the intraindividual comparison of a 1.0 M and two 0.5 M gadolinium-based contrast agents (GBCA) using equimolar dosing in dynamic and static magnetic resonance angiography (MRA) of the supra-aortic vessels. MATERIALS AND METHODS In this institutional review board-approved study, a total of 20 healthy volunteers (mean ± SD age, 29 ± 6 years) underwent 3 consecutive supra-aortic MRA examinations on a 3.0 T magnetic resonance system. The order of GBCA (Gadobutrol, Gadobenate dimeglumine, and Gadoterate meglumine) was randomized with a minimum interval of 48 hours between the examinations. Before each examination and 45 minutes after each examination, circulatory parameters were recorded. Total GBCA dose per MRA examination was 0.1 mmol/kg with a 0.03 mmol/kg and 0.07 mmol/kg split for dynamic and static MRA, respectively, injected at a rate of 2 mL/s. Two blinded readers qualitatively assessed static MRA data sets independently using pairwise rankings (superior, inferior, and equal). In addition, quantitative analysis was performed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) evaluation as well as vessel sharpness analysis of static MRA using an in-house-developed semiautomated tool. Dynamic MRA was evaluated for maximal SNR. Statistical analysis was performed using the Cohen κ, the Wilcoxon rank sum tests, and mixed effects models. RESULTS No significant differences of hemodynamic parameters were observed. In static MRA, Gadobutrol was rated superior to Gadoterate meglumine (P < 0.05) and equal to Gadobenate dimeglumine (P = 0.06) with good to excellent reader agreement (κ, 0.66-0.83). In static MRA, SNR was significantly higher using 1.0 M Gadobutrol as compared with either 0.5 M agent (P < 0.05 and P < 0.05) and CNR was significantly higher as compared with Gadoterate meglumine (P < 0.05), whereas CNR values of Gadobutrol data sets were not significantly different as compared with Gadobenate dimeglumine (P = 0.13). Differences in CNR between Gadobenate dimeglumine and Gadoterate meglumine were not significant (P = 0.78). Differences in vessel sharpness between the different GBCAs were also not significant (P > 0.05). Maximal SNR in dynamic MRA using Gadobutrol was significantly higher than both comparators at the level of the proximal and distal internal carotid artery (P < 0.05 and P < 0.05; P < 0.05 and P < 0.05). CONCLUSIONS At equimolar doses, 1.0 M Gadobutrol demonstrates higher SNR/CNR than do Gadobenate dimeglumine and Gadoterate meglumine, with superior image quality as compared with Gadoterate meglumine for dynamic and static carotid MRA. Despite the shortened bolus with Gadobutrol, no blurring of vessel edges was observed.
Collapse
Affiliation(s)
- Jens Harald Kramer
- Institute for Clinical Radiology, Ludwig Maximilians University Hospital Munich, Munich, Germany.
| | | | | | | | | | | | | |
Collapse
|
21
|
Barbiero G, Cognolato D, Casarin A, Stramanà R, Galzignan E, Guarise A. Carotid artery stenting in difficult aortic arch anatomy with or without a new dedicated guiding catheter: preliminary experience. Eur Radiol 2012. [DOI: 10.1007/s00330-012-2708-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
22
|
|
23
|
The Role of 3 Tesla MRA in the Detection of Intracranial Aneurysms. Int J Vasc Med 2012; 2012:792834. [PMID: 22292121 PMCID: PMC3265088 DOI: 10.1155/2012/792834] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2011] [Accepted: 10/09/2011] [Indexed: 12/01/2022] Open
Abstract
Intracranial aneurysms constitute a common pathological entity, affecting approximately 1–8% of the general population. Their early detection is essential for their prompt treatment. Digital subtraction angiography is considered the imaging method of choice. However, other noninvasive methodologies such as CTA and MRA have been employed in the investigation of patients with suspected aneurysms. MRA is a noninvasive angiographic modality requiring no radiation exposure. However, its sensitivity and diagnostic accuracy were initially inadequate. Several MRA techniques have been developed for overcoming all these drawbacks and for improving its sensitivity. 3D TOF MRA and contrast-enhanced MRA are the most commonly employed techniques. The introduction of 3 T magnetic field further increased MRA's sensitivity, allowing detection of aneurysms smaller than 3 mm. The development of newer MRA techniques may provide valuable information regarding the flow characteristics of an aneurysm. Meticulous knowledge of MRA's limitations and pitfalls is of paramount importance for avoiding any erroneous interpretation of its findings.
Collapse
|