Denton WD, Meredith N, Ozen M. Tracking and Navigation Technologies for Image-Guided Trans-Arterial Interventions. Tech Vasc Interv Radiol 2024; 27:101010. [PMID: 39828388 DOI: 10.1016/j.tvir.2024.101010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2025]
Abstract
Trans-arterial interventions are an increasingly utilized approach for diagnosing and treating a wide range of pathologies, providing superior patient outcomes compared to traditional open surgical methods. Recent advancements in tracking and navigation technologies have significantly refined these interventions, enhancing procedural precision and success. Advanced imaging modalities, such as fluoroscopy, cone beam computed tomography (CBCT), and intravascular ultrasound (IVUS), are frequently used strategies offering critical real-time guidance. Although fluoroscopy remains the primary choice for many procedures, advancements in CBCT and IVUS have enabled the delivery of detailed volumetric and intravascular imaging while reducing radiation exposure. Aiming to enhance imaging capabilities further, image fusion and augmented reality technologies show substantial potential for integrating multiple datasets into cohesive models, improving instrument tracking and spatial orientation during interventions. Innovations in navigation systems, including electromagnetic, fiberoptic, and robotic navigation, provide additional tracking capabilities for enhanced intra-arterial navigation. This article will review the current advancements in imaging, tracking, navigation, and image fusion technologies and explore their utility in enhancing trans-arterial interventions.
Collapse
Affiliation(s)
| | | | - Merve Ozen
- Department of Radiology, Mayo Clinic, Phoenix, AZ.
| |
Collapse
|
2
|
Choi TW, Chung JW. Radiation dose during transarterial chemoembolization and associated factors. Abdom Radiol (NY) 2024; 49:3935-3942. [PMID: 38831076 DOI: 10.1007/s00261-024-04370-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Revised: 05/02/2024] [Accepted: 05/03/2024] [Indexed: 06/05/2024]
Abstract
PURPOSE To provide detailed reports on radiation doses during transarterial chemoembolization (TACE) in the cone-beam computed tomography (CBCT) era and to identify the associated factors. METHODS This retrospective study included 385 consecutive patients who underwent initial conventional TACE for hepatocellular carcinoma (HCC) between January 2016 and December 2017. In most cases, CBCT was performed at the common hepatic artery or celiac axis to confirm the location of the tumor and the three-dimensional hepatic artery anatomy. Superselective TACE was performed for all technically feasible cases. Information on total dose area product (DAP), total cumulative air kerma (CAK), fluoroscopy time, and DAP and CAK of each digital subtraction angiography (DSA) and CBCT scan was recorded. Multiple linear regression analysis was performed to identify the factors associated with increased DAP during TACE. RESULTS The mean values of total DAP and CAK were 165.2 ± 81.2 (Gy·cm²) and 837.1 ± 571.0 (mGy), respectively. The mean fluoroscopy time was 19.1 ± 10.3 min. The mean DAP caused by fluoroscopy, DSA, and CBCT was 51.8 ± 43.9, 28.0 ± 24.1, and 83.9 ± 42.1 Gy·cm², respectively. Male sex, a high body mass index, largest tumor size > 3 cm, presence of aberrant right and left hepatic arteries, and superselective TACE were identified as independent predictors of increased total DAP during TACE. CONCLUSION We were able to provide detailed reports on radiation doses during TACE and associated factors.
Collapse
Affiliation(s)
- Tae Won Choi
- Department of Radiology, Ajou University School of Medicine, Suwon, Korea
| | - Jin Wook Chung
- Department of Radiology, Seoul National University Hospital, Seoul, Korea.
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea.
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea.
| |
Collapse
|
3
|
Brunskill N, Robinson J, Nocum D, Reed W. Exploring software navigation tools for liver tumour angiography: a scoping review. J Med Radiat Sci 2024; 71:261-268. [PMID: 38305074 PMCID: PMC11177025 DOI: 10.1002/jmrs.760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Accepted: 01/19/2024] [Indexed: 02/03/2024] Open
Abstract
INTRODUCTION Liver cancer presents a growing global health concern, necessitating advanced approaches for intervention. This review investigates the use and effectiveness of software navigation in interventional radiology for liver tumour procedures. METHODS In accordance with Preferred Reporting Items for Systematic reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) guidelines, a scoping review was conducted of the literature published between 2013 and 2023 sourcing articles through MEDLINE, Scopus, CINAHL and Embase. Eligible studies focused on liver cancer, utilised cone-beam computed tomography (CBCT), and employed software for intervention. Twenty-one articles were deemed eligible for data extraction and analysis. RESULTS Categorised by type, software applications yielded diverse benefits. Feeder detection software significantly enhanced vessel identification, reducing non-target embolisation by up to 43%. Motion correction software demonstrated a 20% enhancement in image quality, effectively mitigating breathing-induced motion artefacts. Liver perfusion software facilitated efficient tumour targeting while simultaneously reducing the occurrence of side effects. Needle guide software enabled precise radiofrequency ablation needle placement. Additionally, these software applications provided detailed anatomical simulations. Overall, software integration resulted in shorter procedures, reduced radiation exposure and decreased contrast media usage. CONCLUSION This scoping review highlights the innovative yet relatively underexplored role of software navigation for liver tumour procedures. The integration of software applications not only enhances procedural efficiency but also bolsters operator confidence, and contributes to improved patient outcomes. Despite the current lack of uniformity and standardisation, these software-driven advancements hold significant promise for transforming liver tumour interventions. To realise these benefits, further research is needed to explore the clinical impact and optimal utilisation of software navigation tools in interventional radiology.
Collapse
Affiliation(s)
- Nathan Brunskill
- San Radiology & Nuclear MedicineSydney Adventist HospitalWahroongaNew South WalesAustralia
| | - John Robinson
- Sydney School of Health Sciences, Faculty of Medicine and HealthUniversity of SydneyCamperdownNew South WalesAustralia
| | - Don Nocum
- San Radiology & Nuclear MedicineSydney Adventist HospitalWahroongaNew South WalesAustralia
- Sydney School of Health Sciences, Faculty of Medicine and HealthUniversity of SydneyCamperdownNew South WalesAustralia
| | - Warren Reed
- Sydney School of Health Sciences, Faculty of Medicine and HealthUniversity of SydneyCamperdownNew South WalesAustralia
| |
Collapse
|
4
|
Buranurak S, Pong-Inwong V, Hanpanich P, Wongwiwatchai J, Ahooja A, Pungkun V. Al2O3:C optically stimulated luminescence dosimetry for evaluation of potential factors contributing to entrance skin doses received by liver cancer patients undergoing Transarterial Chemoembolization. Radiat Phys Chem Oxf Engl 1993 2023. [DOI: 10.1016/j.radphyschem.2022.110570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
5
|
Greffier J, Dabli D, Kammoun T, Goupil J, Berny L, Touimi Benjelloun G, Beregi JP, Frandon J. Retrospective Analysis of Doses Delivered during Embolization Procedures over the Last 10 Years. J Pers Med 2022; 12:jpm12101701. [PMID: 36294840 PMCID: PMC9605272 DOI: 10.3390/jpm12101701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2022] [Revised: 08/31/2022] [Accepted: 10/06/2022] [Indexed: 11/07/2022] Open
Abstract
Background: This study aimed to retrospectively analyze dosimetric indicators recorded since 2012 for thoracic, abdominal or pelvic embolizations to evaluate the contribution of new tools and technologies in dose reduction. Methods: Dosimetric indicators (dose area product (DAP) and air kerma (AK)) from 1449 embolizations were retrospectively reviewed from August 2012 to March 2022. A total of 1089 embolizations were performed in an older fixed C-Arm system (A1), 222 in a newer fixed C-Arm system (A2) and 138 in a 4DCT system (A3). The embolization procedures were gathered to compare A1, A2 and A3. Results: DAP were significantly lower with A2 compared to A1 for all procedures (median −50% ± 5%, p < 0.05), except for uterine elective embolizations and gonadal vein embolization. The DAP values were significantly lower with A3 than with A1 (p < 0.001). CT scan was used for guidance in 90% of embolization procedures. Conclusions: The last C-Arm technology allowed a median reduction of 50% of the X-ray dose. The implementation of a CT scan inside the IR room allowed for more precise 3D-guidance with no increase of the dose delivered.
Collapse
Affiliation(s)
- Joël Greffier
- IMAGINE UR UM 103, Department of Medical Imaging, Montpellier University, Nîmes University Hospital, 30029 Nîmes, France
- Department of Medical Physics, Nîmes University Hospital, 30029 Nîmes, France
- Correspondence: ; Tel.: +33-466-683-309
| | - Djamel Dabli
- IMAGINE UR UM 103, Department of Medical Imaging, Montpellier University, Nîmes University Hospital, 30029 Nîmes, France
- Department of Medical Physics, Nîmes University Hospital, 30029 Nîmes, France
| | - Tarek Kammoun
- IMAGINE UR UM 103, Department of Medical Imaging, Montpellier University, Nîmes University Hospital, 30029 Nîmes, France
| | - Jean Goupil
- IMAGINE UR UM 103, Department of Medical Imaging, Montpellier University, Nîmes University Hospital, 30029 Nîmes, France
| | - Laure Berny
- IMAGINE UR UM 103, Department of Medical Imaging, Montpellier University, Nîmes University Hospital, 30029 Nîmes, France
| | - Ghizlane Touimi Benjelloun
- IMAGINE UR UM 103, Department of Medical Imaging, Montpellier University, Nîmes University Hospital, 30029 Nîmes, France
| | - Jean-Paul Beregi
- IMAGINE UR UM 103, Department of Medical Imaging, Montpellier University, Nîmes University Hospital, 30029 Nîmes, France
| | - Julien Frandon
- IMAGINE UR UM 103, Department of Medical Imaging, Montpellier University, Nîmes University Hospital, 30029 Nîmes, France
| |
Collapse
|
6
|
Radiation dose reduction during adrenal vein sampling using a new angiographic imaging technology. Sci Rep 2022; 12:6067. [PMID: 35414704 PMCID: PMC9005500 DOI: 10.1038/s41598-022-09984-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Accepted: 03/30/2022] [Indexed: 11/29/2022] Open
Abstract
To compare the patient radiation doses during angiographic selective adrenal vein sampling (AVS) before and after an imaging technology upgrade. In this retrospective single-center-study, cumulative air kerma (AK), cumulative dose area product (DAP), fluoroscopy time and contrast agent dosage were recorded from 70 patients during AVS. 35 procedures were performed before and 35 after an imaging processing technology upgrade. Mean values were calculated and compared using an unpaired student’s t-test. DSA image quality was assessed independently by two blinded readers using a four-point Likert scale (1 = poor; 4 = excellent) and compared using Wilcoxon signed-rank test. After the technology upgrade we observed a significant reduction of 35% in AK (1.7 ± 0.7 vs. 1.1 ± 0.7 Gy, p = 0.01) and a significant reduction of 28% in DAP (235.1 ± 113 vs. 170.1 ± 94 Gy*cm2, p = 0.01) in comparison to procedures before the upgrade. There were no significant differences between the number of exposure frames (143 ± 86 vs. 132 ± 61 frames, p = 0.53), fluoroscopy time (42 ± 23 vs. 36 ± 18 min, p = 0.22), or the amount of contrast medium used (179.5 ± 84 vs. 198.1 ± 109 ml, p = 0.41). There was also no significant difference regarding image quality (3 (2–4) vs. 3 (2–4), p = 0.67). The angiographic imaging technology upgrade significantly decreases the radiation dose during adrenal vein sampling without increasing time of fluoroscopy or contrast volume and without compromising image quality.
Collapse
|
7
|
Pizano A, Khurram A, Chamseddin K, Timaran CH, Baig S, Shih M, Xi Y, Guild J, Kirkwood ML. New imaging technology system reduces patient radiation dose during peripheral arterial endovascular interventions. J Vasc Surg 2022; 76:500-504. [PMID: 35367567 DOI: 10.1016/j.jvs.2022.03.865] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Accepted: 03/23/2022] [Indexed: 11/24/2022]
Abstract
BACKGROUND Radiation exposure and imaging quality are among the main concerns in endovascular procedures. The Clear VD11 PURE platform technology system (Siemens Healthineers, Erlangen, Germany) has been reported to lower the radiation dose and improve image quality. In the present study, we evaluated whether the radiation dose during peripheral arterial endovascular procedures had decreased after implementation of this new imaging system. METHODS The patient characteristics (age, gender, body mass index [BMI]), procedure type (diagnostic, balloon angioplasty, atherectomy, stenting), body location (aortoiliac, superficial femoral artery, tibial artery), reference air kerma (RAK), kerma area product (KAP), and fluoroscopy time (FT) were recorded during peripheral artery interventions performed 1 year before (group A) and 1 year after (group B) the CLEAR system upgrade. The procedures were performed in an Artis zeego hybrid room (Siemens Healthineers) with the same providers. A general linear model was used to estimate the average difference between groups adjusted by procedure type and patient age, gender, and BMI. Additionally, to control for variations in case complexity, groups A and B were matched by age, gender, BMI, lesion location, and intervention type. Propensity score matching and a paired t test were used to compare the KAP, RAK, and FT stratified by single intervention procedures. RESULTS A total of 487 endovascular procedures were performed: 209 in group A and 278 in group B. A total of 111 single intervention procedures from each group were matched (1:1), with a mean age of 61 ± 8 years and a BMI of 26.5 ± 4 kg/m2. The median KAP, RAK, and FT for group A were 28.8 Gy · cm2 (interquartile range [IQR], 24-34 Gy · cm2), 146 mGy (IQR, 123-173 mGy), and 12 minutes (IQR, 10-14 minutes), respectively. The median KAP, RAK, and FT for group B were 18.3 Gy · cm2 (IQR, 16-22 Gy · cm2), 71.2 mGy (IQR, 60-85 mGy), and 10.4 minutes (IQR, 9-12 minutes), respectively. The KAP, RAK, and FT were significantly decreased in group B by 24% (P = .005), 41% (P < .001), and 22% (P = .002), respectively, compared with the values for group A. Stratified by single intervention procedures, the KAP and RAK had decreased significantly in group B (36% [P = .002] and 51% [P < .001], respectively) compared with group A. The FT decrease of 13% in group B was not statistically significant (P = .20). CONCLUSIONS Use of the Clear VD11 PURE platform system (Siemens Healthineers) reduced the patient radiation dose by 51% during endovascular peripheral interventions. The similar FTs for the matched single intervention procedures before and after the upgrade indicated consistent case complexity and surgeon practice. This platform appears to be an effective system for lowering the radiation dose.
Collapse
Affiliation(s)
- Alejandro Pizano
- Division of Vascular and Endovascular Surgery, Department of Surgery, University of Texas Southwestern Medical Center, Dallas, TX
| | - Ali Khurram
- Division of Vascular and Endovascular Surgery, Department of Surgery, University of Texas Southwestern Medical Center, Dallas, TX
| | - Khalil Chamseddin
- Division of Vascular and Endovascular Surgery, Department of Surgery, University of Texas Southwestern Medical Center, Dallas, TX
| | - Carlos H Timaran
- Division of Vascular and Endovascular Surgery, Department of Surgery, University of Texas Southwestern Medical Center, Dallas, TX
| | - Shadman Baig
- Division of Vascular and Endovascular Surgery, Department of Surgery, University of Texas Southwestern Medical Center, Dallas, TX
| | - Michael Shih
- Division of Vascular and Endovascular Surgery, Department of Surgery, University of Texas Southwestern Medical Center, Dallas, TX
| | - Yin Xi
- Division of Medical Physics, Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX
| | - Jeffrey Guild
- Division of Medical Physics, Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX
| | - Melissa L Kirkwood
- Division of Vascular and Endovascular Surgery, Department of Surgery, University of Texas Southwestern Medical Center, Dallas, TX.
| |
Collapse
|
8
|
McCaughey C, Healy GM, Al Balushi H, Maher P, McCavana J, Lucey J, Cantwell CP. Patient radiation dose during angiography and embolization for abdominal hemorrhage: the influence of CT angiography, fluoroscopy system, patient and procedural variables. CVIR Endovasc 2022; 5:12. [PMID: 35171363 PMCID: PMC8850522 DOI: 10.1186/s42155-022-00284-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2021] [Accepted: 01/06/2022] [Indexed: 11/19/2022] Open
Abstract
Background Angiography and embolization (AE) is a lifesaving, high radiation dose procedure for treatment of abdominal arterial hemorrhage (AAH). Interventional radiologists have utilized pre-procedure CT angiography (CTA) and newer fluoroscopic systems in an attempt to reduce radiation dose and procedure time. Purpose To study the factors contributing to the radiation dose of AE for AAH and to compare to the reference standard. Materials and methods This retrospective single-centre observational cohort study identified 154 consecutive AE procedures in 138 patients (median age 65 years; interquartile range 54–77; 103 men) performed with a C-arm fluoroscopic system (Axiom Artis DTA or Axiom Artis Q (Siemens Healthineers)), between January 2010 and December 2017. Parameters analysed included: demographics, fluoroscopy system, bleeding location, body mass index (BMI), preprocedural CT, air kerma-area product (PKA), reference air kerma (Ka,r), fluoroscopy time (FT) and the number of digital subtraction angiography (DSA) runs. Factors affecting dose were assessed using Mann–Whitney U, Kruskal–Wallis one-way ANOVA and linear regression. Results Patients treated with the new angiographic system (NS) had a median PKA, median Ka,r, Q3 PKA and Q3 Ka,r that were 74% (p < 0.0005), 66%(p < 0.0005), 55% and 52% lower respectively than those treated with the old system (OS). This dose reduction was consistent for each bleeding location (upper GI, Lower GI and extraluminal). There was no difference in PKA (p = 0.452), Ka,r (p = 0.974) or FT (p = 0.179), between those who did (n = 137) or did not (n = 17) undergo pre-procedure CTA. Other factors significantly influencing radiation dose were: patient BMI and number of DSA runs. A multivariate model containing these variables accounts for 15.2% of the variance in Ka,r (p < 0.005) and 45.9% of the variance of PKA (p < 0.005). Conclusion Radiation dose for AE in AAH is significantly reduced by new fluoroscopic technology. Higher patient body mass index is an independent key parameter affecting patient dose. Radiation dose was not influenced by haemorrhage site or performance of pre-procedure CTA.
Collapse
Affiliation(s)
| | - Gerard M Healy
- Department of Radiology, St Vincent's University Hospital, Dublin, Ireland
| | | | - Patrice Maher
- Department of Radiology, St Vincent's University Hospital, Dublin, Ireland
| | - Jackie McCavana
- Department of Medical Physics and Clinical Engineering, St Vincent's University Hospital, Dublin, Ireland
| | - Julie Lucey
- Department of Medical Physics and Clinical Engineering, St Vincent's University Hospital, Dublin, Ireland
| | - Colin P Cantwell
- Department of Radiology, St Vincent's University Hospital, Dublin, Ireland.,School of Medicine, University College Dublin, Dublin, Ireland
| |
Collapse
|
9
|
Nocum DJ, Robinson J, Halaki M, Båth M, Thompson JD, Thompson N, Moscova M, Liang E, Mekiš N, Reed W. Predictors of radiation dose for uterine artery embolisation are angiography system-dependent. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2022; 42:011502. [PMID: 34985415 DOI: 10.1088/1361-6498/ac480b] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Accepted: 01/04/2022] [Indexed: 06/14/2023]
Abstract
This study sought to achieve radiation dose reductions for patients receiving uterine artery embolisation (UAE) by evaluating radiation dose measurements for the preceding generation (Allura) and upgraded (Azurion) angiography system. Previous UAE regression models in the literature could not be applied to this centre's practice due to being based on different angiography systems and radiation dose predictor variables. The aims of this study were to establish whether radiation dose is reduced with the upgraded angiography system and to develop a regression model to determine predictors of radiation dose specific to the upgraded angiography system. A comparison between Group I (Allura,n= 95) and Group II (Azurion,n= 95) demonstrated a significant reduction in kerma-area product (KAP) and Ka, r (reference air kerma) by 63% (143.2 Gy cm2vs 52.9 Gy cm2;P< 0.001,d= 0.8) and 67% (0.6 Gy vs 0.2 Gy;P< 0.001,d= 0.8), respectively. The multivariable linear regression (MLR) model identified the UAE radiation dose predictors for KAP on the upgraded angiography system as total fluoroscopy dose, Ka, r, and total uterus volume. The predictive accuracy of the MLR model was assessed using a Bland-Altman plot. The mean difference was 0.39 Gy cm2and the limits of agreement were +28.49 and -27.71 Gy cm2, and thus illustrated no proportional bias. The resultant MLR model was considered system-dependent and validated the upgraded angiography system and its advance capabilities to significantly reduce radiation dose. Interventional radiologist and interventional radiographer familiarisation of the system's features and the implementation of the newly established MLR model would further facilitate dose optimisation for all centres performing UAE procedures using the upgraded angiography system.
Collapse
Affiliation(s)
- Don J Nocum
- SAN Radiology & Nuclear Medicine, Sydney Adventist Hospital, Wahroonga, New South Wales, Australia
- Discipline of Medical Imaging Science, Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia
| | - John Robinson
- Discipline of Medical Imaging Science, Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia
- Medical Imaging Optimisation and Perception Group (MIOPeG), Discipline of Medical Imaging Science, Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia
| | - Mark Halaki
- Discipline of Exercise and Sport Science, Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia
| | - Magnus Båth
- Department of Medical Radiation Sciences, Institute of Clinical Sciences, The Sahlgrenska Academy, University of Gothenburg, Gothenburg SE-413 45, Sweden
- Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45 Gothenburg, Sweden
| | - John D Thompson
- Department of Radiography, School of Health and Society, University of Salford, Salford M6 6PU, United Kingdom
| | - Nadine Thompson
- SAN Radiology & Nuclear Medicine, Sydney Adventist Hospital, Wahroonga, New South Wales, Australia
- School of Medicine, Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia
| | - Michelle Moscova
- Faculty of Medicine and Health, School of Medical Sciences, University of New South Wales, Sydney, New South Wales, Australia
| | - Eisen Liang
- SAN Radiology & Nuclear Medicine, Sydney Adventist Hospital, Wahroonga, New South Wales, Australia
- Sydney Fibroid Clinic, Sydney Adventist Hospital, Wahroonga, New South Wales, Australia
| | - Nejc Mekiš
- Medical Imaging and Radiotherapy Department, Faculty of Health Sciences, University of Ljubljana, Ljubljana, Slovenia
| | - Warren Reed
- Discipline of Medical Imaging Science, Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia
- Medical Imaging Optimisation and Perception Group (MIOPeG), Discipline of Medical Imaging Science, Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia
| |
Collapse
|
10
|
Yuan H, Lu H, Zeng J, Zhang Y, Shen L. Comparison of radiation doses between hepatic artery infusion chemotherapy and transarterial chemoembolization for liver cancer. J Interv Med 2021; 4:184-189. [PMID: 35586376 PMCID: PMC8947989 DOI: 10.1016/j.jimed.2021.08.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 08/06/2021] [Accepted: 08/08/2021] [Indexed: 01/12/2023] Open
Abstract
Objective To analyze the radiation dose received by patients during hepatic artery infusion chemotherapy (HAIC) and transarterial chemoembolization (TACE) procedures and the related influencing factors. Methods Data of 162 cases in the HAIC group and 230 cases in the TACE group were collected. The included covariates were Age (<45/45–59/≥60 years), BMI levels (underweight/normal weight/obesity), focus Dye of tumor (present/absent), lesion size (<5cm/≥5cm), superselection (present/absent), hepatic vascular variation (present/absent). The endpoints were postoperative dose-area product (DAP), exposure time and Air kerma (AK). Results Of all included patients, the HAIC group patients were younger than those in the TACE group (P = 0.028). The proportion of patients with large lesions in the HAIC group was higher than the TACE group (45.7% vs. 33.9%, P = 0.019). The proportion of patients who had superselection was lower in the HAIC group as compared to the TACE group (61.7% vs. 82.2%, P < 0.001). Generally, the HAIC group has lower DAP, exposure time and AK by 36.3% (P < 0.001), 38.2% (P < 0.001), and 41.3% (P < 0.001) than the TACE group, respectively. Linear regression analysis showed the procedure method (HAIC/TACE, P < 0.001), type of DSA machine (Pheno/FD20, P < 0.001), BMI levels (P < 0.001), age (P = 0.021), lesion size (<5cm/≥5 cm, P = 0.031) significantly correlated with low DAP. In the HAIC group, the type of DSA machine and BMI correlated with the radiation dose, while in the TACE group, the type of DSA machine, BMI, and lesion size correlated with the radiation dose. Conclusion Compared with TACE, HAIC enables doctors and patients to receive lower radiation doses. Obese patients in both HAIC and TACE groups increase the radiation exposure in interventional doctors and patients, but large lesions only affect the radiation dose in the TACE procedure.
Collapse
|
11
|
González-Ruíz A, Ou-Saada I, Isidro-Ortega FJ, Sánchez-Mendoza HI. Local dose reference levels during transarterial chemoembolization procedure. Appl Radiat Isot 2021; 178:109982. [PMID: 34655924 DOI: 10.1016/j.apradiso.2021.109982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 09/28/2021] [Accepted: 10/07/2021] [Indexed: 11/17/2022]
Abstract
The aim of this study was to develop local diagnostic reference levels (LDRL) during Transarterial chemoembolization (TACE). This cross-sectional study reports radiation dose indicators of 108 patients in a Mexican hospital, obtained over a period of 35 months. Kerma-area product (PKA), air-kerma at the reference point (Ka, r), and descriptive statistical analysis were examined according to sociodemographic characteristics of the sample patients. The LDRL obtained were then compared to a similar international framework. The present study contributes to the establishment of a TACE LDRL and identifies significant correlations among radiology factors and dosimetric quantities obtained.
Collapse
Affiliation(s)
- Abraham González-Ruíz
- Universidad Autónoma del Estado de México, Paseo Tollocan S/N, Toluca, Estado de México, 50180, México
| | - Imane Ou-Saada
- Laboratory of High Energy Physics, Modelling and Simulations Faculty of Sciences Rabat, Mohammed V University, 4 Avenue Ibn Battouta B.P. 1014, Rabat, Morocco
| | - Frank Jhonatan Isidro-Ortega
- División de Estudios de Posgrado e Investigación, Instituto Tecnológico de Toluca, Metepec, 52149, Estado de México, México
| | - Helen's Irais Sánchez-Mendoza
- Instituto Nacional de Salud Pública, Fray Pedro de Gante 12, Belisario Domínguez Secc 16, Tlalpan, 14080, Ciudad de México, México.
| |
Collapse
|
12
|
El-Diasty MT, Olfat AA, Mufti AS, Alqurashi AR, Alghamdi MJ. Patients' Radiation Shielding in Interventional Radiology Settings: A Systematic Review. Cureus 2021; 13:e16870. [PMID: 34513445 PMCID: PMC8412000 DOI: 10.7759/cureus.16870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/03/2021] [Indexed: 11/05/2022] Open
Abstract
As a result of the increasing risk of developing radiation-related complications, many approaches aimed at reducing this risk and enhancing the outcomes of the patient, doctor or device operator have been developed. In this systematic review, we aim to discuss previous investigations that studied patient shielding or protection within the context of selected interventional radiology procedures. We included original studies that used Ka,r, and PKA for the assessment of the outcomes of two procedures: transjugular intrahepatic portosystemic shunt creation (TIPS) and hepatic arterial chemoembolization (HAE). A thorough search strategy was conducted on relevant databases to identify all relevant studies. We included 13 investigations, including 12 cross-sectional studies and one randomized controlled trial. Significant diversity was found among all these studies in terms of the used modalities, which made them hard to compare. However, almost all studies agreed that using novel imaging and interventional modalities is useful when obtaining better outcomes and reducing patient radiation exposure. The use of ultrasound-guided procedures and providing adequate lead curtains has also been recommended by the identified studies in order to minimize the frequency of radiation exposure. The reported Ka,r, and PKA were also variable between studies and were discussed within this study. Our findings indicate that unified guidelines for patient radiation shielding should be urgently investigated.
Collapse
Affiliation(s)
| | - Ahmed A Olfat
- Department of Radiology, King Abdullah Medical City, Mecca, SAU
| | - Ahmad S Mufti
- Department of Radiology, King Abdullah Medical City, Mecca, SAU
| | - Ahmed R Alqurashi
- Department of Radiology, King Abdulaziz University Hospital, Jeddah, SAU
| | | |
Collapse
|
13
|
Javor D, Moyses J, Loewe C, Schernthaner RE. Radiation dose reduction capabilities of a new C-arm system with optimized hard- and software. Eur J Radiol 2020; 134:109367. [PMID: 33221618 DOI: 10.1016/j.ejrad.2020.109367] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2020] [Revised: 10/17/2020] [Accepted: 10/20/2020] [Indexed: 11/30/2022]
Abstract
PURPOSE To assess the radiation dose reduction capabilities and the image quality of a new C-arm system in comparison to a standard C-arm system. METHOD Prospective, randomized, IRB approved two-arm trial design. 49 consecutive patients with primary or secondary liver cancer were treated with transarterial chemoembolization (TACE) on two different angiography units. 28 patients were treated on a conventional angiography unit B, 21 patients on unit A which provides improved hardware and optimized image processing algorithms. Dose area product (DAP) and fluoroscopy time were recorded. DSA image quality of all procedures was assessed on a four-rank-scale by two independent and blinded readers. RESULTS Both cohorts showed no significant differences with regard to patient characteristics, tumor burden and fluoroscopy time. The new system resulted in a statistically significant reduction of cumulative DAP of 72% compared to the old platform (median 76 vs. 269 Gy*cm2). Individually, Fluoro-DAP and DSA-DAP decreased by 48% and 77% (p = 0.012 and p < 0.01), respectively. No statistically significant differences in DSA image quality were found between the two imaging platforms. CONCLUSIONS The new C-arm system significantly reduced radiation exposure for TACE procedures without increased radiation time or negative impact on DSA image quality. The combination of optimized hardware and software yields the highest radiation dose reduction and is of utmost importance for patients and interventionalists.
Collapse
Affiliation(s)
- Domagoj Javor
- Division of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
| | - Johanna Moyses
- Division of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria
| | - Christian Loewe
- Division of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria
| | - Ruediger E Schernthaner
- Division of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria
| |
Collapse
|
14
|
Ban J, Peng L, Li P, Liu Y, Zhou T, Xu G, Zhang X. Performance of Double-Arm Digital Subtraction Angiography (DSA)-Guided and C-Arm-Guided Percutaneous Kyphoplasty (PKP) to Treat Senile Osteoporotic Vertebral Compression Fractures. Med Sci Monit 2020; 26:e923619. [PMID: 32799216 PMCID: PMC7448688 DOI: 10.12659/msm.923619] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Background Osteoporotic vertebral compression fracture (OVCF) is a common fracture in the elderly. Conservative treatment requires prolonged bedding, which may lead to serious complications. To explore optimized use of percutaneous kyphoplasty (PKP) in the treatment of senile osteoporotic thoracolumbar vertebral compression fractures, in this study, we used C-arm-guided and double-arm digital subtraction angiography (DSA)-guided PKP to treat OVCF in elderly patients and analyzed the effective recovery. Material/Methods In all, 60 patients who presented with osteoporotic vertebral compression fractures at our hospital between July 2017 and February 2019 were analyzed. They were randomly divided into C-arm-guided group and the double-arm DSA-guided groups. Both groups were treated with percutaneous kyphoplasty. Results A pain VAS score analysis revealed that there was no significant difference between the two groups before surgery (P>0.05). After surgery, the VAS scores showed a significant difference between the C-arm-guided group and the double-arm DSA-guided PKP treatment group (P<0.01). Moreover, with respect to the bone cement dosage, vertebral correction height, operation time, cumulative radiation dose, percolation rate, and volume of bone cement, the double-arm DSA-guided PKP treatment showed significantly better results than the C-arm-guided PKP treatment (P<0.01). Conclusions Our data revealed that double-arm DSA-guided PKP was more accurate in treatment of senile osteoporotic thoracolumbar vertebral compression fractures, producing excellent performance with more accurate intraoperative evaluation, shorter operative time, lower incidence of bone cement leakage, less intraoperative radiation dose, and higher safety, and thus, could be extensively applied to clinical surgery.
Collapse
Affiliation(s)
- Jihe Ban
- Department of Orthopedics, Zhejiang Rongjun Hospital, Jiaxing, Zhejiang, China (mainland)
| | - Lilu Peng
- Department of Orthopedics, Zhejiang Rongjun Hospital, Jiaxing, Zhejiang, China (mainland)
| | - Pengpeng Li
- Department of Orthopedics, Zhejiang Rongjun Hospital, Jiaxing, Zhejiang, China (mainland)
| | - Yunhai Liu
- Department of Orthopedics, Zhejiang Rongjun Hospital, Jiaxing, Zhejiang, China (mainland)
| | - Tao Zhou
- Department of Invasive Technology, Zhejiang Rongjun Hospital, Jiaxing, Zhejiang, China (mainland)
| | - Guangtao Xu
- Forensic and Pathology Laboratory, Judicial Expertise Center, Jiaxing University Medical College, Jiaxing, Zhejiang, China (mainland)
| | - Xingen Zhang
- Department of Orthopedics, Zhejiang Rongjun Hospital, Jiaxing, Zhejiang, China (mainland)
| |
Collapse
|
15
|
Utility of 'dual phase' cone beam computed tomography during radioembolisation in patients with hepatocellular carcinoma: what is really changing in flow dynamics before and after 90Y delivery? Pol J Radiol 2020; 85:e21-e28. [PMID: 32180850 PMCID: PMC7064008 DOI: 10.5114/pjr.2020.92915] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2019] [Accepted: 12/17/2019] [Indexed: 12/24/2022] Open
Abstract
Purpose The aims of the study were: 1) to compare two phases of dual-phase cone beam computed tomography (DP-CBCT) achieved before and after Yttrium-90 (90Y) administration and to evaluate additional benefits during radioembolisation (RE) procedures; and 2) to compare DP-CBCT with pre-procedure contrast enhanced cross-sectional images in terms of tumour detection. Material and methods Twenty-three hepatocellular carcinoma patients undergoing RE treatment were scanned with DP-CBCT consisting of early arterial (EA) and late arterial (LA) phases before and after 90Y administration. The CT-like datasets were compared according to embolisation effect, enhancement patterns, lesion detectability, image quality, and artifacts by two interventional radiologists blinded to each other. The compatibility of the two radiologists was evaluated with kappa statistical analysis, and the difference between EA and LA phases was evaluated with marginal homogeneity test. Also, DP-CBCT images were compared with preprocedural cross-sectional images (CT/MRI). Results For 23 patients 92 data were acquired. Thirteen patients showed a decrease on post-embolisation images both visually and on Hounsfield unit (HU) measurements. No statistical difference was found for tumour detection between EA and LA phases (p = 1.0). Tumour enhancement was visually superior at LA phases whereas EA phases were better for arterial mapping for selective catheterisation. DP-CBCT images were not inferior to preprocedural cross-sectional imaging findings. Conclusions DP-CBCT is a promising tool for predicting tumour response to therapy and is not inferior to preprocedural cross-sectional imaging in terms of tumour detection. It allows better assessment during RE procedures because early phases provide good mapping for superselective catheterisation whereas late phases are better for visualisation of tumour enhancement.
Collapse
|
16
|
Haochen W, Yinghua Z, Jian W. Intrahepatic arterial localizer guided transjugular intrahepatic portosystemic shunt placement: Feasibility, efficacy, and technical success assessed by a case series-a STROBE- compliant article. Medicine (Baltimore) 2019; 98:e16868. [PMID: 31415422 PMCID: PMC6831380 DOI: 10.1097/md.0000000000016868] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/23/2023] Open
Abstract
Transjugular intra-hepatic portosystemic shunts (TIPS) had been considered a standard procedure in patients suffering from portal hypertension. The most challenging step in TIPS placement is blind puncture of the portal vein. We had established a localization method by introducing an Intra-Hepatic Arterial based puncture directing Localizer (IHAL) with the assistance of the enhanced computed tomography (CT) reconstruction. This study aimed to evaluate the feasibility, efficacy, and technical success of this method.From June 2018 to August 2018, 10 consecutive patients suffering from refractory ascites or esophageal gastric bleeding by liver cirrhosis were included in this retrospective study to evaluate feasibility, efficacy, and technical success of enhanced CT assisted IHAL-guided puncture of the portal vein. As a control, 10 patients receiving TIPS placement before Jun 2018 with cone beam CT (CBCT)-guided puncture were included to compare the reduction of portal-systemic pressure gradient (PSPG), portal entry time (PET), the number of puncture, dose area product (DAP) and contrast medium consumption.Technical success was 100% in the study group (IHAL-guided group) and in 90.0% of the control group (CBCT-guided group). Appropriate IHAL point could be achieved in all patients under the enhanced CT reconstruction assistance. The median number of punctures and DAP in IHAL group were significantly less than those in CBCT group. The reduction of PSPG, PET, and contrast medium consumption in IHAL group showed no significant differences than those in CBCT group.Enhanced CT reconstruction assisted IHAL-guided portal vein puncture is technically feasible and a reliable tool for TIPS placement resulting in a significant reduction of the number of punctures and DAP.
Collapse
|
17
|
Hersh-Boyle RA, Culp WTN, Brown DC, Luskin AC, Kapatkin AS, Chou PY, Agnello KA, Reetz JA, Oyama MA, Visser LC, Palm CA, Clarke DL. Radiation exposure of dogs and cats undergoing fluoroscopic procedures and for operators performing those procedures. Am J Vet Res 2019; 80:558-564. [PMID: 31140847 DOI: 10.2460/ajvr.80.6.558] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To evaluate radiation exposure of dogs and cats undergoing procedures requiring intraoperative fluoroscopy and for operators performing those procedures. SAMPLE 360 fluoroscopic procedures performed at 2 academic institutions between 2012 and 2015. PROCEDURES Fluoroscopic procedures were classified as vascular, urinary, respiratory, cardiac, gastrointestinal, and orthopedic. Fluoroscopy operators were classified as interventional radiology-trained clinicians, orthopedic surgeons, soft tissue surgeons, internists, and cardiologists. Total radiation exposure in milligrays and total fluoroscopy time in minutes were obtained from dose reports for 4 C-arm units. Kruskal-Wallis equality of populations rank tests and Dunn pairwise comparisons were used to compare differences in time and exposure among procedures and operators. RESULTS Fluoroscopy time (median, 35.80 minutes; range, 0.60 to 84.70 minutes) was significantly greater and radiation exposure (median, 137.00 mGy; range, 3.00 to 617.51 mGy) was significantly higher for vascular procedures than for other procedures. Median total radiation exposure was significantly higher for procedures performed by interventional radiology-trained clinicians (16.10 mGy; range, 0.44 to 617.50 mGy), cardiologists (25.82 mGy; range, 0.33 to 287.45 mGy), and internists (25.24 mGy; range, 3.58 to 185.79 mGy). CONCLUSIONS AND CLINICAL RELEVANCE Vascular fluoroscopic procedures were associated with significantly longer fluoroscopy time and higher radiation exposure than were other evaluated fluoroscopic procedures. Future studies should focus on quantitative radiation monitoring for patients and operators, importance of operator training, intraoperative safety measures, and protocols for postoperative monitoring of patients.
Collapse
|
18
|
Advanced Robotic Angiography Systems for Image Guidance During Conventional Transarterial Chemoembolization. Invest Radiol 2019; 54:153-159. [DOI: 10.1097/rli.0000000000000519] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
19
|
Thomaere E, Dehairs M, Laenen A, Mehrsima A, Timmerman D, Cornelissen S, Op de Beeck K, Bosmans H, Maleux G. A new imaging technology to reduce the radiation dose during uterine fibroid embolization. Acta Radiol 2018; 59:1446-1450. [PMID: 29486598 DOI: 10.1177/0284185118760064] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
BACKGROUND Uterine fibroid embolization (UFE) is a minimally invasive imaging-guided treatment using radiation exposure. PURPOSE To compare the patients' radiation exposure during UFE before and after introduction of a new X-ray imaging platform. MATERIAL AND METHODS Forty-one patients were enrolled in a prospective, comparative two-arm project before and after introduction of a new X-ray imaging platform with reduced dose settings, i.e. novel real-time image processing techniques (AlluraClarity). Demographic, pre-interventional imaging, and procedural data, including dose area product (DAP) and estimated organ dose on the ovaries and uterus, were recorded and angiographic quality of overall procedure was assessed. RESULTS There were no significant differences in demographic characteristics and preoperative fibroid and uterine volumes in the two groups. The new imaging platform led to a significant reduction in mean total DAP (102 vs. 438 Gy.cm2; P < 0.001), mean fluoroscopy DAP (32 vs. 138 Gy.cm2; P < 0.001), mean acquisition DAP (70 vs. 300 Gy.cm2; P < 0.001), and acquisition DAP estimated organ dose in ovaries (42 vs. 118 mGy; P < 0.001) and uterus (40 vs. 118 mGy, P < 0.001), without impairment of the procedure and angiographic image quality. CONCLUSION A substantial 77% reduction of DAP values and 64% and 66% reduction in organ dose on ovaries and uterus, respectively, was demonstrated with the new imaging platform, while maintaining optimal imaging quality and efficacy.
Collapse
Affiliation(s)
- Eveline Thomaere
- Department of Radiology, University Hospitals Leuven, Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
| | - Michiel Dehairs
- Department of Radiology, Section of Medical Physics, University Hospitals Leuven, Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
| | - Annouschka Laenen
- Interuniversity Centre for Biostatistics and Statistical Bioinformatics, Catholic University of Leuven and University Hasselt, Leuven, Belgium
| | | | - Dirk Timmerman
- Department of Gynecology, University Hospitals Leuven, Leuven, Belgium
| | - Sandra Cornelissen
- Department of Radiology, Section of Interventional Radiology, University Hospitals Leuven, Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
| | - Katya Op de Beeck
- Department of Radiology, University Hospitals Leuven, Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
| | - Hilde Bosmans
- Department of Radiology, Section of Medical Physics, University Hospitals Leuven, Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
| | - Geert Maleux
- Department of Radiology, Section of Interventional Radiology, University Hospitals Leuven, Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
| |
Collapse
|
20
|
Jonczyk M, Collettini F, Geisel D, Schnapauff D, Böning G, Wieners G, Gebauer G. Radiation exposure during TACE procedures using additional cone-beam CT (CBCT) for guidance: safety and precautions. Acta Radiol 2018; 59:1277-1284. [PMID: 29490465 DOI: 10.1177/0284185118761203] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Background During transarterial chemoembolization (TACE), cone-beam computed tomography (CBCT) can be used for tumor and feeding vessel detection as well as postembolization CT imaging. However, there will be additional radiation exposure from CBCT. Purpose To evaluate the additional dose raised through CBCT-assisted guidance in comparison to TACE procedures guided with pulsed digital subtraction angiography (DSA) alone. Material and Methods In 70 of 140 consecutive patients undergoing TACE for liver cancer, CBCT was used to facilitate the TACE. Cumulative dose area product (DAP), cumulative kerma(air), DAP values of DSA, total and cine specific fluoroscopy times (FT) of 1375 DSA runs, and DAP of 91 CBCTs were recorded and analyzed using Spearman's correlation, Mann-Whitney U-test, and Kruskal-Wallis test. P values < 0.05 were considered significant. Results Additional CBCT increased DAP by 2% ( P = 0.737), kerma(air) by 24.6% ( P = 0.206), and FT by 0.02% ( P = 0.453). Subgroup analysis revealed that postembolization CBCT for detection of ethiodized oil deposits added more DAP to the procedure. Performing CBCT-assisted TACE, DSA until first CBCT contributed about 38% to the total DAP. Guidance CBCT acquisitions conduced to 6% of the procedure's DAP. Additional DSA for guidance after CBCT acquisition required approximately 46% of the mean DAP. The last DSA run for documentation purposes contributed about 10% of the DAP. Conclusion CBCT adds radiation exposure in TACE. However, the capability of CBCT to detect vessels and overlay in real-time during fluoroscopy facilitates TACE with resultant reduction of DAPs up to 46%.
Collapse
Affiliation(s)
- M Jonczyk
- Department of Radiology, Charité University Medicine Berlin, Berlin, Germany
- Berlin Institute of Health (BIH), Berlin, Germany
| | - F Collettini
- Department of Radiology, Charité University Medicine Berlin, Berlin, Germany
- Berlin Institute of Health (BIH), Berlin, Germany
| | - D Geisel
- Department of Radiology, Charité University Medicine Berlin, Berlin, Germany
| | - D Schnapauff
- Department of Radiology, Charité University Medicine Berlin, Berlin, Germany
| | - G Böning
- Department of Radiology, Charité University Medicine Berlin, Berlin, Germany
| | - G Wieners
- Department of Radiology, Charité University Medicine Berlin, Berlin, Germany
| | - G Gebauer
- Department of Radiology, Charité University Medicine Berlin, Berlin, Germany
| |
Collapse
|
21
|
Jonczyk M, Collettini F, Schnapauff D, Geisel D, Böning G, Lüdemann WM, Wieners G, Hamm B, Gebauer B. Visibility of Hypovascularized Liver Tumors during Intra-Arterial Therapy Using Split-Bolus Single-Phase Cone Beam CT. Cardiovasc Intervent Radiol 2018; 42:260-267. [PMID: 30374613 DOI: 10.1007/s00270-018-2101-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2018] [Accepted: 10/19/2018] [Indexed: 01/31/2023]
Abstract
PURPOSE To validate a split-bolus contrast injection protocol for single-phase CBCT in terms of detectability of hypovascular liver tumors compared to digital subtraction angiography (DSA). MATERIALS AND METHODS In this retrospective, single-center study, 20 consecutive patients with in total 77 hypovascularized tumors referred for intra-arterial therapy received a split-bolus single-phase CBCT. Two readers rated the visibility of the target tumors scheduled for embolization in CBCT and DSA compared to the pre-interventional multiphasic CT or MRI used as reference on a 3-point scoring system (1 = optimal, 3 = not visible) and catheter-associated artifacts (1 = none, 3 = extended). SNR, CNR and contrast values were derived from 37 target tumors in CBCT and MRI. Statistical analysis included the kappa test to determine interrater reliability, the Friedman's test for the inter-modality comparison evaluating tumor visibility in DSA and CBCT as well as for quantitative assessment. Post hoc analysis included the Wilcoxon signed-rank test. p values < 0.05 were considered significant. RESULTS Ninety percentage of target tumors were rated as visible in CBCT and 37.5% in DSA (p < 0.001). 70.1% of pre-interventionally detected hypovascularized tumors were depicted with CBCT and 31.2% by DSA (p < 0.001). 7.8% of known tumors were outside the FOV. Quantitative assessment showed higher image contrasts in CBCT (1.91 ± 7.01) compared to hepatobiliary-phase MRI (0.29 ± 0.14, p = 0.003) and to portal-venous (p.v.) MRI (0.31 ± 0.13, p < 0.001), but higher CNR for MRI (1.18 ± 0.80; 13.92 ± 15.82; 13.79 ± 6.65). CONCLUSION In conclusion, the split-bolus single-phase CBCT detects significantly more hypovascularized liver tumors compared to DSA performed through the proper hepatic artery with high image contrasts. LEVEL OF EVIDENCE Level III, diagnostic study.
Collapse
Affiliation(s)
- Martin Jonczyk
- Department of Radiology, Charité - Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany. .,Berlin Institute of Health (BIH), Anna-Louisa-Karsch 2, 10178, Berlin, Germany.
| | - Federico Collettini
- Department of Radiology, Charité - Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany.,Berlin Institute of Health (BIH), Anna-Louisa-Karsch 2, 10178, Berlin, Germany
| | - Dirk Schnapauff
- Department of Radiology, Charité - Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Dominik Geisel
- Department of Radiology, Charité - Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Georg Böning
- Department of Radiology, Charité - Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Willie M Lüdemann
- Department of Radiology, Charité - Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Gero Wieners
- Department of Radiology, Charité - Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Bernd Hamm
- Department of Radiology, Charité - Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Bernhard Gebauer
- Department of Radiology, Charité - Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
| |
Collapse
|
22
|
Panick C, Wunderle K, Sands M, Martin C. Patient Radiation Dose Reduction Considerations in a Contemporary Interventional Radiology Suite. Cardiovasc Intervent Radiol 2018; 41:1925-1934. [PMID: 30132101 DOI: 10.1007/s00270-018-2052-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Accepted: 08/01/2018] [Indexed: 02/07/2023]
Abstract
PURPOSE We sought to evaluate patient radiation exposure during complex liver interventional procedures performed with newer angiography equipment. MATERIALS AND METHODS We conducted a retrospective study of transjugular intrahepatic portosystemic shunt (TIPS) creations and liver tumor embolizations performed in our new angiography suite (Discovery IGS740, GE Healthcare). T tests were used to compare air kerma-area product (PKA) and reference plane air kerma (Ka,r) in the new room versus data from historical rooms and previous studies (including the RAD IR study). Results were expressed as medians [interquartile ranges (Q1, Q3)]. RESULTS From February 2015 to June 2016, 134 complex liver interventional procedures were performed in the new room, including 14 TIPS creations, 60 hepatic tumor arterial embolizations (HAEs), 26 Y90 mappings (Y90m), and 34 Y90 radioembolizations (Y90). Ka,r (Gy) values were as follows: TIPS, 0.65 (0.24, 1.15); HAE, 0.89 (0.49, 1.49); Y90m, 0.54 (0.38, 0.94); Y90, 0.46 (0.21, 1.06). PKA (Gy·cm2) values were as follows: TIPS, 148.2 (66.7, 326.5); HAE, 142.6 (88, 217.8); Y90m, 148.3 (98.2, 247); Y90, 90.8 (43.9, 161.5). Ka,r and PKA were lower in the new room than in historical rooms [Ka,r and PKA reductions: TIPS, 58 and 49%; HAE, 31 and 39%; Y90m, 58 and 52%; Y90, 49 and 56% (p < 0.05)] and versus the RAD IR study [Ka,r and PKA reductions: TIPS, 64 and 43%; HAE, 26 and 40% (p < 0.05)]. CONCLUSIONS Using the latest technology and image processing tools enables significant reduction in radiation exposure during complex liver interventional procedures.
Collapse
Affiliation(s)
- Catherine Panick
- Case Western Reserve University School of Medicine, 10900 Euclid Avenue, Cleveland, OH, 44106, USA
| | - Kevin Wunderle
- Diagnostic Radiology, Imaging Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA
| | - Mark Sands
- Diagnostic Radiology, Imaging Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA
| | - Charles Martin
- Diagnostic Radiology, Imaging Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.
| |
Collapse
|
23
|
Abstract
Interventional radiology in veterinary medicine was adapted from techniques developed in human medicine, and has a variety of applications to treat disease in multiple body systems. Fluoroscopy is required for almost all interventional procedures, requiring knowledge of proper safety techniques for working with ionizing radiation. There are a wide variety of catheters, wires, sheaths, stents, and embolics used in veterinary medicine. Familiarity with their indications and sizing compatibility is essential for procedural success.
Collapse
|
24
|
Radiation dose reduction with frame rate conversion in X-ray fluoroscopic imaging systems with flat panel detector: basic study and clinical retrospective analysis. Eur Radiol 2018; 29:985-992. [DOI: 10.1007/s00330-018-5620-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Revised: 06/09/2018] [Accepted: 06/19/2018] [Indexed: 12/27/2022]
|
25
|
Pereira PL, Krüger K, Hohenstein E, Welke F, Sommer C, Meier F, Eigentler T, Garbe C. Intraprocedural 3D perfusion measurement during chemoembolisation with doxorubicin-eluting beads in liver metastases of malignant melanoma. Eur Radiol 2018; 28:1456-1464. [PMID: 29124381 DOI: 10.1007/s00330-017-5099-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2016] [Revised: 07/30/2017] [Accepted: 09/27/2017] [Indexed: 12/12/2022]
Abstract
OBJECTIVES To study feasibility and validity of a new software application for intraprocedural assessment of perfusion during chemoembolisation of melanoma metastases. METHODOLOGY In a prospective phase-II trial, ten melanoma patients with liver-only metastases underwent chemoembolisation with doxorubicin-eluting beads (DEBDOX-TACE). Tumour perfusion was evaluated immediately before and after treatment at cone beam computer tomography (CBCT) using a new software application. For control and comparison, patients underwent perfusion measurement via contrast-enhanced multidetector CT (MDCT) before and after treatment. RESULTS CBCT showed 94.7 % reduction in perfusion in metastases after DEBDOX-TACE, whereas MDCT showed 96.8 %. Reduction in perfusion after treatment was statistically significant (p < 0.01) for both methods. The additional time needed for data acquisition during treatment was 5 min per case or less; the post-processing data analysis was 10 min or less. Perfusion imaging was associated with additional contrast agent and patient exposure to radiation (dose-length product [DLP]): 18 ml and 394 mGy*cm in CBCT and 100 ml and 446 mGy*cm in MDCT, respectively. CONCLUSIONS Reduction in perfusion of melanoma metastases after DEBDOX-TACE can be reliably assessed during the intervention via perfusion software at CBCT. Data acquisition and analysis require additional time but can be easily performed during the treatment. KEY POINTS • Tumour perfusion of melanoma metastases can be assessed at cone beam CT. • The software shows a significant decrease of tumour perfusion after DEBDOX-TACE. • Data acquisition and analysis require an acceptable additional time during the procedure. • CBCT requires less radiation exposure and contrast for perfusion study than MSCT. • This software can monitor the course of DEBDOX-TACE in melanoma metastases.
Collapse
Affiliation(s)
- Philippe L Pereira
- Clinic for Radiology, Minimally-Invasive Therapies and Nuclearmedicine, SLK-Kliniken GmbH, Heilbronn, Am Gesundbrunnen 20-26, 74078, Heilbronn, Germany.
| | - Kristina Krüger
- Clinic for Radiology, Minimally-Invasive Therapies and Nuclearmedicine, SLK-Kliniken GmbH, Heilbronn, Am Gesundbrunnen 20-26, 74078, Heilbronn, Germany
| | - Ernst Hohenstein
- Clinic for Radiology, Minimally-Invasive Therapies and Nuclearmedicine, SLK-Kliniken GmbH, Heilbronn, Am Gesundbrunnen 20-26, 74078, Heilbronn, Germany
| | - Florian Welke
- Institute for Diagnostic and Interventional Radiology, Klinikum Ludwigsburg, Posilipostraße 4, 71640, Ludwigsburg, Germany
| | - Christof Sommer
- Clinic for Diagnostic and Interventional Radiology, Ruprecht Karls University of Heidelberg, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany
| | - Friedegund Meier
- Clinic for Dermato-Oncology, Universitätsklinikum Carl Gustav Carus, Fiedlerstraße 19, 01307, Dresden, Germany
| | - Thomas Eigentler
- Clinic für Dermato-Oncology, Eberhard-Karls University, Liebermeisterstraße 25, 72076, Tübingen, Germany
| | - Claus Garbe
- Clinic für Dermato-Oncology, Eberhard-Karls University, Liebermeisterstraße 25, 72076, Tübingen, Germany
| |
Collapse
|
26
|
Spink C, Avanesov M, Schmidt T, Grass M, Schoen G, Adam G, Koops A, Ittrich H, Bannas P. Noise reduction angiographic imaging technology reduces radiation dose during bronchial artery embolization. Eur J Radiol 2017; 97:115-118. [PMID: 29153361 DOI: 10.1016/j.ejrad.2017.10.029] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2017] [Revised: 10/25/2017] [Accepted: 10/30/2017] [Indexed: 10/18/2022]
Abstract
PURPOSE Comparison of radiation doses in patients undergoing angiographic bronchial artery embolization (BAE) before and after a noise reduction imaging technology upgrade. METHODS We performed a retrospective study of 70 patients undergoing BAE. Procedures were performed before (n=32) and after (n=38) the technology upgrade containing additional filters and improved image-processing. Cumulative air kerma (AK), cumulative dose area product (DAP), number of exposure frames, total fluoroscopy time and amount of contrast agent were recorded. Mean values were calculated and compared using two-tailed t-tests. DSA image quality was assessed independently by two blinded readers and compared using the Wilcoxon signed-rank test. RESULTS Using the new technology resulted in a significant reduction of 59% in DAP (149.2 (103.1-279.1) vs. 54.8 (38.2-100.7) Gy*cm2, p<0.001) and a significant reduction of 60% for AK (1.3 (0.6-1.9) vs. 0.5 (0.3-0.9) Gy, p<0.001) in comparison to procedures before the upgrade. There was no significant difference between the number of exposure frames in both groups (251±181 vs. 254±133 frames, p=0.07), time of fluoroscopy (28.8 (18.5-50.4) vs. 28.1 (23.3-38.7) min, p=0.73), or the amount of contrast agent used (139.5±70.8 vs. 163.1±63.1ml, p=0.11). No significant difference regarding image quality could be detected (3 (2,3) vs. 3 (2-4), p=0.64). CONCLUSIONS The new angiographic noise reduction technology significantly decreases the radiation dose during bronchial artery embolization without compromising image quality or increasing time of fluoroscopy or contrast volume.
Collapse
Affiliation(s)
- C Spink
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| | - M Avanesov
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - T Schmidt
- Philips Healthcare, Hamburg, Germany
| | - M Grass
- Philips Healthcare, Hamburg, Germany
| | - G Schoen
- Department of Medical Biometry and Epidemiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - G Adam
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - A Koops
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - H Ittrich
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - P Bannas
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
27
|
Characteristics of a New X-Ray Imaging System for Interventional Procedures: Improved Image Quality and Reduced Radiation Dose. Cardiovasc Intervent Radiol 2017; 41:502-508. [PMID: 29090348 PMCID: PMC5801377 DOI: 10.1007/s00270-017-1821-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/10/2017] [Accepted: 10/12/2017] [Indexed: 01/28/2023]
Abstract
Purpose To compare image quality and radiation exposure between a new angiographic imaging system and the preceding generation system during uterine artery embolization (UAE). Materials and Methods In this retrospective, IRB-approved two-arm study, 54 patients with symptomatic uterine fibroids were treated with UAE on two different angiographic imaging systems. The new system includes optimized acquisition parameters and real-time image processing algorithms. Air kerma (AK), dose area product (DAP) and acquisition time for digital fluoroscopy (DF) and digital subtraction angiography (DSA) were recorded. Body mass index was noted as well. DF image quality was assessed objectively by image noise measurements. DSA image quality was rated by two blinded, independent readers on a four-rank scale. Statistical differences were assessed with unpaired t tests and Wilcoxon rank-sum tests. Results There was no significant difference between the patients treated on the new (n = 36) and the old system (n = 18) regarding age (p = 0.10), BMI (p = 0.18), DF time (p = 0.35) and DSA time (p = 0.17). The new system significantly reduced the cumulative AK and DAP by 64 and 72%, respectively (median 0.58 Gy and 145.9 Gy*cm2 vs. 1.62 Gy and 526.8 Gy*cm2, p < 0.01 for both). Specifically, DAP for DF and DSA decreased by 59% (75.3 vs. 181.9 Gy*cm2, p < 0.01) and 78% (67.6 vs. 312.2 Gy*cm2, p < 0.01), respectively. The new system achieved a significant decrease in DF image noise (p < 0.01) and a significantly better DSA image quality (p < 0.01). Conclusions The new angiographic imaging system significantly improved image quality and reduced radiation exposure during UAE procedures. Electronic supplementary material The online version of this article (doi:10.1007/s00270-017-1821-z) contains supplementary material, which is available to authorized users.
Collapse
|
28
|
Studzińska E, Staniszewska MA. Impact of Allura Clarity Technology on Radiation Dose Exposure During Left Atrial Appendage Closure. Pol J Radiol 2017; 82:598-602. [PMID: 29662591 PMCID: PMC5894036 DOI: 10.12659/pjr.902350] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2016] [Accepted: 01/24/2017] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND To evaluate the impact of the Clarity IQ technology on reducing radiation risk in patients undergoing cardiac interventional radiology (IR) procedures. MATERIAL/METHODS Phantom studies were performed with two angiographic systems, FD10 Allura Xper and FD10 Allura Clarity. In the study, we performed left atrial appendage closure. Dosimetric measurements were performed with thermoluminescent dosimeters (TLD) placed inside a CIRS anthropomorphic phantom. Radiation risk was estimated based on the TLD readings and expressed as the dose absorbed by particular organs. The Mann-Whitney U test was carried out to test for significance of differences in the absorbed radiation doses between the techniques. RESULTS During left atrial appendage closure, the estimated dose absorbed by particular organs was lower in the case of the FD10 Allura Clarity system in comparison to the Allura Xper. In this procedure, dose reduction for particular organs ranged between 49-86%. CONCLUSIONS Application of the FD10 Allura Clarity system resulted in a significant dose reduction, thereby leading to a significant decrease in radiation risk for patients undergoing IR procedures.
Collapse
|
29
|
Diagnostic Accuracy of Split-Bolus Single-Phase Contrast-Enhanced Cone-Beam CT for the Detection of Liver Tumors before Transarterial Chemoembolization. J Vasc Interv Radiol 2017; 28:1378-1385. [DOI: 10.1016/j.jvir.2017.05.018] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2017] [Revised: 05/24/2017] [Accepted: 05/24/2017] [Indexed: 12/30/2022] Open
|
30
|
Abstract
The clinical management of hepatocellular carcinoma has evolved greatly in the last decade mostly through recent technical innovations. In particular, the application of cutting-edge image guidance has led to minimally invasive solutions for complex clinical problems and rapid advances in the field of interventional oncology. Many image-guided therapies, such as transarterial chemoembolization and radiofrequency ablation, have meanwhile been fully integrated into interdisciplinary clinical practice, whereas others are currently being investigated. This review summarizes and evaluates the most relevant completed and ongoing clinical trials, provides a synopsis of recent innovations in the field of intraprocedural imaging and tumor response assessment, and offers an outlook on new technologies, such as radiopaque embolic materials. In addition, combination therapies consisting of locoregional therapies and systemic molecular targeted agents (e.g., sorafenib) remain of major interest to the field and are also discussed. Finally, we address the many substantial advances in immune response pathways that have been related to the systemic effects of locoregional therapies. Knowledge of these new developments is crucial as they continue to shape the future of cancer treatment, further establishing interventional oncology along with surgical, medical, and radiation oncology as the fourth pillar of cancer care.
Collapse
|
31
|
Baumann F, Peña C, Kloeckner R, Katzen BT, Gandhi R, Benenati JB. The Effect of a New Angiographic Imaging Technology on Radiation Dose in Visceral Embolization Procedures. Vasc Endovascular Surg 2017; 51:183-187. [PMID: 28424042 DOI: 10.1177/1538574417698903] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE To evaluate the impact of a new angiographic imaging technology on radiation dose during visceral embolization procedures involving both fluoroscopy and digital subtraction angiography. MATERIAL AND METHODS A retrospective analysis from a single-center consecutive series of patients was performed comparing 2 angiographic imaging systems. The AlluraClarity (CIQ; Philips Healthcare, Best, the Netherlands) was used in 100 patients (n = 59 male, mean age: 70.6 years) from July 2013 to April 2014 and compared to the former AlluraXper (AX) technology used in 139 patients (n = 71 male, mean age: 70.1 years) from May 2011 to June 2013. Patients were categorized according to body mass index (BMI [kg/m2])-group 1: BMI <25, group 2: BMI ≥25 and <30, and group 3: BMI ≥30. Fluoroscopy time, the total dose of iodinated contrast administered, and procedural AirKerma (Ka, r [mGy]) were obtained. RESULTS Mean BMI was 26.4 ± 5.0 kg/m2 in the CIQ and 26.4 ± 7.1 kg/m2 in the AX group ( P = .93). Fluoroscopy time and the amount of contrast media were equally distributed. Ka, r was 1342.9 mGy versus 2214.8 mGy ( P < .001, t test) when comparing CIQ to AX. Comparing CIQ to AX, BMI subgroup analysis revealed a mean Ka, r of 970.1 to 1586.1 mGy ( P = .003, t test), 1484.7 to 2170.1 mGy ( P = .02, t test), and 1848.8 to 3348.9 mGy ( P = .001, t test) in BMI groups 1, 2, and 3, respectively. CONCLUSION The CIQ technology significantly reduced mean radiation dose by 39.4% for visceral embolization procedures when compared to fluoroscopy time and contrast media dose. This dose relationship was consistent across all BMI groups.
Collapse
Affiliation(s)
- Frederic Baumann
- 1 Miami Cardiac & Vascular Institute, Baptist Hospital, Miami, FL, USA.,2 Clinical and Interventional Angiology, University Hospital of Zurich, Zurich, Switzerland
| | - Constantino Peña
- 1 Miami Cardiac & Vascular Institute, Baptist Hospital, Miami, FL, USA
| | - Roman Kloeckner
- 2 Clinical and Interventional Angiology, University Hospital of Zurich, Zurich, Switzerland.,3 Clinic for Interventional Radiology, University Hospital of Mainz, Mainz, Germany
| | - Barry T Katzen
- 1 Miami Cardiac & Vascular Institute, Baptist Hospital, Miami, FL, USA
| | - Ripal Gandhi
- 1 Miami Cardiac & Vascular Institute, Baptist Hospital, Miami, FL, USA
| | - James B Benenati
- 1 Miami Cardiac & Vascular Institute, Baptist Hospital, Miami, FL, USA
| |
Collapse
|
32
|
Abstract
Hepatocellular carcinoma (HCC) is the second most common cause of cancer-related deaths worldwide with rapidly growing incidence rates in the USA and Europe. Despite improving surveillance programs, most patients are diagnosed at intermediate to advanced stages and are no longer amenable to curative therapies, such as ablation, surgical resection and liver transplantation. For such patients, catheter-based image-guided embolotherapies such as transarterial chemoembolization (TACE) represent the standard of care and mainstay therapy, as recommended and endorsed by a variety of national guidelines and staging systems. The main benefit of these therapies is explained by the preferentially arterial blood supply of liver tumors, which allows to deliver the anticancer therapy directly to the tumor-feeding artery while sparing the healthy hepatic tissue mainly supplied by the portal vein. The tool box of an interventional oncologist contains several different variants of transarterial treatment modalities. Ever since the first TACE more than 30 years ago, these techniques have been progressively refined, both with respect to drug delivery materials and with respect to angiographic micro-catheter and image-guidance technology, thus substantially improving therapeutic outcomes of HCC. This review will summarize the fundamental principles, technical and clinical data on the application of different embolotherapies, such as bland transarterial embolization, Lipiodol-based conventional transarterial chemoembolization as well as TACE with drug-eluting beads (DEB-TACE). Clinical data on 90Yttrium radioembolization as an emerging alternative, mostly applied for niche indications such as HCC with portal vein invasion, will be discussed. Furthermore, we will summarize the principle of HCC staging, patient allocation and response assessment in the setting of HCC embolotherapy. In addition, we will evaluate the role of cone-beam computed tomography as a novel intra-procedural image-guidance technology. Finally, this review will touch on new technical developments such as radiopaque, imageable DEBs and the rationale and role of combined systemic and locoregional therapies, mostly in combination with Sorafenib.
Collapse
|
33
|
Establishing Local Diagnostic Reference Levels in IR Procedures with Dose Management Software. J Vasc Interv Radiol 2017; 28:429-441. [DOI: 10.1016/j.jvir.2016.10.006] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2016] [Revised: 10/01/2016] [Accepted: 10/12/2016] [Indexed: 11/21/2022] Open
|
34
|
Spink C, Avanesov M, Schmidt T, Grass M, Schoen G, Adam G, Bannas P, Koops A. Radiation dose reduction during transjugular intrahepatic portosystemic shunt implantation using a new imaging technology. Eur J Radiol 2016; 86:284-288. [PMID: 28027761 DOI: 10.1016/j.ejrad.2016.11.028] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2016] [Revised: 11/15/2016] [Accepted: 11/23/2016] [Indexed: 02/07/2023]
Abstract
OBJECTIVE To compare patient radiation dose in patients undergoing transjugular intrahepatic portosystemic shunt (TIPS) implantation before and after an imaging-processing technology upgrade. METHODS In our retrospective single-center-study, cumulative air kerma (AK), cumulative dose area product (DAP), total fluoroscopy time and contrast agent were collected from an age- and BMI-matched collective of 108 patients undergoing TIPS implantation. 54 procedures were performed before and 54 after the technology upgrade. Mean values were calculated and compared using two-tailed t-tests. Two blinded, independent readers assessed DSA image quality using a four-rank likert scale and the Wilcoxcon test. RESULTS The new technology demonstrated a significant reduction of 57% of mean DAP (402.8 vs. 173.3Gycm2, p<0.001) and a significant reduction of 58% of mean AK (1.7 vs. 0.7Gy, p<0.001) compared to the precursor technology. Time of fluoroscopy (26.4 vs. 27.8min, p=0.45) and amount of contrast agent (109.4 vs. 114.9ml, p=0.62) did not differ significantly between the two groups. The DSA image quality of the new technology was not inferior (2.66 vs. 2.77, p=0.56). CONCLUSIONS In our study the new imaging technology halved radiation dose in patients undergoing TIPS maintaining sufficient image quality without a significant increase in radiation time or contrast consumption.
Collapse
Affiliation(s)
- C Spink
- Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| | - M Avanesov
- Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - T Schmidt
- Philips Healthcare, Hamburg, Germany
| | - M Grass
- Philips Research, Hamburg, Germany
| | - G Schoen
- Department of Medical Biometry and Epidemiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - G Adam
- Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - P Bannas
- Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - A Koops
- Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
35
|
Schernthaner RE, Haroun RR, Duran R, Lee H, Sahu S, Sohn JH, Chapiro J, Zhao Y, Gorodetski B, Fleckenstein F, Smolka S, Radaelli A, van der Bom IM, Lin M, Geschwind JF. Improved Visibility of Metastatic Disease in the Liver During Intra-Arterial Therapy Using Delayed Arterial Phase Cone-Beam CT. Cardiovasc Intervent Radiol 2016; 39:1429-37. [PMID: 27380872 PMCID: PMC5009166 DOI: 10.1007/s00270-016-1406-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2015] [Accepted: 05/31/2016] [Indexed: 12/26/2022]
Abstract
Purpose To compare the visibility of liver metastases on dual-phase cone-beam CT (DP-CBCT) and digital subtraction angiography (DSA), with reference to preinterventional contrast-enhanced magnetic resonance imaging (CE-MRI) of the liver. Methods This IRB-approved, retrospective study included 28 patients with neuroendocrine (NELM), colorectal (CRCLM), or sarcoma (SLM) liver metastases who underwent DP-CBCT during intra-arterial therapy (IAT) between 01/2010 and 10/2014. DP-CBCT was acquired after a single contrast agent injection in the tumor-feeding arteries at early and delayed arterial phases (EAP and DAP). The visibility of each lesion was graded by two radiologists in consensus on a three-rank scale (complete, partial, none) on DP-CBCT and DSA images using CE-MRI as reference. Results 47 NELM, 43 CRCLM, and 16 SLM were included. On DSA 85.1, 44.1, and 37.5 % of NELM, CRCLM, and SLM, were at least partially depicted, respectively. EAP-CBCT yielded significantly higher sensitivities of 88.3 and 87.5 % for CRCLM and SLM, respectively (p < 0.01), but not for NELM (89.4 %; p = 1.0). On DAP-CBCT all NELM, CRCLM, and SLM were visible (p < 0.001). Complete depiction was achieved on DSA for 59.6, 16.3, and 18.8 % of NELM, CRCLM, and SLM, respectively. The complete depiction rate on EAP-CBCT was significantly higher for CRCLM (46.5 %; p < 0.001), lower for NELM (40.4 %; p = 0.592), and similar for SLM (25 %, p = 0.399). On DAP-CBCT however, the highest rates of complete depiction were found—NELM (97.8 %; p = 0.008), CRCLM (95.3 %; p = 0.008), and SLM (100 %; p < 0.001). Conclusion DAP-CBCT substantially improved the visibility of liver metastases during IAT. Future studies need to evaluate the clinical impact.
Collapse
Affiliation(s)
- Ruediger E Schernthaner
- Section of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.,Department of Radiology and Biomedical Imaging, Yale University School of Medicine, 330 Cedar Street, TE 2-230, New Haven, CT, 06520, USA
| | - Reham R Haroun
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, 330 Cedar Street, TE 2-230, New Haven, CT, 06520, USA
| | - Rafael Duran
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, 330 Cedar Street, TE 2-230, New Haven, CT, 06520, USA
| | - Howard Lee
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, 330 Cedar Street, TE 2-230, New Haven, CT, 06520, USA
| | - Sonia Sahu
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, 330 Cedar Street, TE 2-230, New Haven, CT, 06520, USA
| | - Jae Ho Sohn
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, 330 Cedar Street, TE 2-230, New Haven, CT, 06520, USA
| | - Julius Chapiro
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, 330 Cedar Street, TE 2-230, New Haven, CT, 06520, USA
| | - Yan Zhao
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, 330 Cedar Street, TE 2-230, New Haven, CT, 06520, USA
| | - Boris Gorodetski
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, 330 Cedar Street, TE 2-230, New Haven, CT, 06520, USA
| | - Florian Fleckenstein
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, 330 Cedar Street, TE 2-230, New Haven, CT, 06520, USA
| | - Susanne Smolka
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, 330 Cedar Street, TE 2-230, New Haven, CT, 06520, USA
| | | | | | - MingDe Lin
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, 330 Cedar Street, TE 2-230, New Haven, CT, 06520, USA.,U/S Imaging and Interventions, Philips Research North America, Cambridge, MA, USA
| | - Jean Francois Geschwind
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, 330 Cedar Street, TE 2-230, New Haven, CT, 06520, USA.
| |
Collapse
|
36
|
Three-dimensional C-arm CT-guided transjugular intrahepatic portosystemic shunt placement: Feasibility, technical success and procedural time. Eur Radiol 2016; 26:4277-4283. [PMID: 27048535 DOI: 10.1007/s00330-016-4340-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Revised: 03/16/2016] [Accepted: 03/17/2016] [Indexed: 02/07/2023]
Abstract
OBJECTIVES Establishment of transjugular intrahepatic portosystemic shunts (TIPS) constitutes a standard procedure in patients suffering from portal hypertension. The most difficult step in TIPS placement is blind puncture of the portal vein. This study aimed to evaluate three-dimensional mapping of portal vein branches and targeted puncture of the portal vein. METHODS Twelve consecutive patients suffering from refractory ascites by liver cirrhosis were included in this retrospective study to evaluate feasibility, technical success and procedural time of C-arm CT-targeted puncture of the portal vein. As a control, 22 patients receiving TIPS placement with fluoroscopy-guided blind puncture were included to compare procedural time. RESULTS Technical success could be obtained in 100 % of the study group (targeted puncture) and in 95.5 % of the control group (blind puncture). Appropriate, three-dimensional C-arm CT-guided mapping of the portal vein branches could be achieved in all patients. The median number of punctures in the C-arm CT-guided study group was 2 ± 1.3 punctures. Procedural time was significantly lower in the study group (14.8 ± 8.2 min) compared to the control group (32.6 ± 22.7 min) (p = 0.02). CONCLUSIONS C-arm CT-guided portal vein mapping is technically feasible and a promising tool for TIPS placement resulting in a significant reduction of procedural time. KEY POINTS • C-arm CT-mapping of the portal vein for 3D TIPS guidance is feasible. • Targeted punctures of the portal vein by C-arm CT reduce procedural time. • A decreased number of punctures could improve patient safety.
Collapse
|
37
|
Reducing Patient Radiation Dose With Image Noise Reduction Technology in Transcatheter Aortic Valve Procedures. Am J Cardiol 2016; 117:834-8. [PMID: 26742472 DOI: 10.1016/j.amjcard.2015.12.016] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2015] [Revised: 12/03/2015] [Accepted: 12/03/2015] [Indexed: 12/30/2022]
Abstract
X-ray radiation exposure is of great concern for patients undergoing structural heart interventions. In addition, a larger group of medical staff is required and exposed to radiation compared with percutaneous coronary interventions. This study aimed at quantifying radiation dose reduction with implementation of specific image noise reduction technology (NRT) in transcatheter aortic valve implantation (TAVI) procedures. We retrospectively analyzed 104 consecutive patients with TAVI procedures, 52 patients before and 52 after optimization of x-ray radiation chain, and implementation of NRT. Patients with 1-step TAVI and complex coronary intervention, or complex TAVI procedures, were excluded. Before the procedure, all patients received a multislice computed tomography scan, which was used to size aortic annulus, select the optimal implantation plane, valve type and size, and guide valve implantation using a software tool. Air kerma and kerma-area product were compared in both groups to determine patient radiation dose reduction. Baseline parameters, co-morbidity, or procedural data were comparable between groups. Mean kerma-area product was significantly lower (p <0.001) in the NRT group compared with the standard group (60 ± 39 vs 203 ± 106 Gy × cm(2), p <0.001), which corresponds to a reduction of 70%. Mean air kerma was reduced by 64% (494 ± 360 vs 1,355 ± 657 mGy, p <0.001). In conclusion, using optimized x-ray chain combined with specific image noise reduction technology has the potential to significantly reduce by 2/3 radiation dose in standard TAVI procedures without worsening image quality or prolonging procedure time.
Collapse
|
38
|
van Strijen MJ. Reply to: “Comments on “Evaluation of a Noise Reduction Imaging Technology in Iliac Digital Subtraction Angiography: Noninferior Clinical Image Quality with Lower Patient and Scatter Dose”“. J Vasc Interv Radiol 2015; 26:1420-1. [DOI: 10.1016/j.jvir.2015.06.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2015] [Accepted: 06/16/2015] [Indexed: 10/23/2022] Open
|
39
|
Kohlbrenner R, Kolli KP, Taylor AG, Kohi MP, Fidelman N, LaBerge JM, Kerlan RK, Agarwal VK, Lehrman ED, Nanavati S, Avrin DE, Gould R. Patient Radiation Dose Reduction during Transarterial Chemoembolization Using a Novel X-Ray Imaging Platform. J Vasc Interv Radiol 2015. [DOI: 10.1016/j.jvir.2015.06.016] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
40
|
Schernthaner RE, Chapiro J, Sahu S, Withagen P, Duran R, Sohn JH, Radaelli A, van der Bom IM, Geschwind JFH, Lin M. Feasibility of a Modified Cone-Beam CT Rotation Trajectory to Improve Liver Periphery Visualization during Transarterial Chemoembolization. Radiology 2015; 277:833-41. [PMID: 26000642 DOI: 10.1148/radiol.2015142821] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
PURPOSE To compare liver coverage and tumor detectability by using preprocedural magnetic resonance (MR) images as a reference, as well as radiation exposure of cone-beam computed tomography (CT) with different rotational trajectories. MATERIALS AND METHODS Fifteen patients (nine men and six women; mean age ± standard deviation, 65 years ± 5) with primary or secondary liver cancer were retrospectively included in this institutional review board-approved study. A modified cone-beam CT protocol was used in which the C-arm rotates from +55° to -185° (open arc cone-beam CT) instead of -120° to +120° (closed arc cone-beam CT). Each patient underwent two sessions of transarterial chemoembolization between February 2013 and March 2014 with closed arc and open arc cone-beam CT (during the first and second transarterial chemoembolization sessions, respectively, as part of the institutional transarterial chemoembolization protocol). For each cone-beam CT examination, liver volume and tumor detectability were assessed by using MR images as the reference. Radiation exposure was compared by means of a phantom study. For statistical analysis, paired t tests and a Wilcoxon signed rank test were performed. RESULTS Mean liver volume imaged was 1695 cm(3) ± 542 and 1857 cm(3) ± 571 at closed arc and open arc cone-beam CT, respectively. The coverage of open arc cone-beam CT was significantly higher compared with closed arc cone-beam CT (97% vs 86% of the MR imaging liver volume, P = .002). In eight patients (53%), tumors were partially or completely outside the closed arc cone-beam CT field of view. All tumors were within the open arc cone-beam CT field of view. The open arc cone-beam CT radiation exposure by means of weighted CT index was slightly lower compared with that of closed arc cone-beam CT (-5.1%). CONCLUSION Open arc cone-beam CT allowed for a significantly improved intraprocedural depiction of peripheral hepatic tumors while achieving a slight radiation exposure reduction.
Collapse
Affiliation(s)
- Rüdiger E Schernthaner
- From the Russell H. Morgan Department of Radiology and Radiological Science, Division of Vascular and Interventional Radiology, The Johns Hopkins Hospital, 1800 Orleans St, Sheikh Zayed Tower, Suite 7203, Baltimore, MD 21287 (R.E.S., J.C., S.S., R.D., J.H.S., J.F.H.G.); Philips Healthcare, Best, the Netherlands (P.W., A.R., I.M.v.d.B.); and Department of Ultrasound and Interventions, Philips Research North America, Briarcliff Manor, NY (M.L.)
| | - Julius Chapiro
- From the Russell H. Morgan Department of Radiology and Radiological Science, Division of Vascular and Interventional Radiology, The Johns Hopkins Hospital, 1800 Orleans St, Sheikh Zayed Tower, Suite 7203, Baltimore, MD 21287 (R.E.S., J.C., S.S., R.D., J.H.S., J.F.H.G.); Philips Healthcare, Best, the Netherlands (P.W., A.R., I.M.v.d.B.); and Department of Ultrasound and Interventions, Philips Research North America, Briarcliff Manor, NY (M.L.)
| | - Sonia Sahu
- From the Russell H. Morgan Department of Radiology and Radiological Science, Division of Vascular and Interventional Radiology, The Johns Hopkins Hospital, 1800 Orleans St, Sheikh Zayed Tower, Suite 7203, Baltimore, MD 21287 (R.E.S., J.C., S.S., R.D., J.H.S., J.F.H.G.); Philips Healthcare, Best, the Netherlands (P.W., A.R., I.M.v.d.B.); and Department of Ultrasound and Interventions, Philips Research North America, Briarcliff Manor, NY (M.L.)
| | - Paul Withagen
- From the Russell H. Morgan Department of Radiology and Radiological Science, Division of Vascular and Interventional Radiology, The Johns Hopkins Hospital, 1800 Orleans St, Sheikh Zayed Tower, Suite 7203, Baltimore, MD 21287 (R.E.S., J.C., S.S., R.D., J.H.S., J.F.H.G.); Philips Healthcare, Best, the Netherlands (P.W., A.R., I.M.v.d.B.); and Department of Ultrasound and Interventions, Philips Research North America, Briarcliff Manor, NY (M.L.)
| | - Rafael Duran
- From the Russell H. Morgan Department of Radiology and Radiological Science, Division of Vascular and Interventional Radiology, The Johns Hopkins Hospital, 1800 Orleans St, Sheikh Zayed Tower, Suite 7203, Baltimore, MD 21287 (R.E.S., J.C., S.S., R.D., J.H.S., J.F.H.G.); Philips Healthcare, Best, the Netherlands (P.W., A.R., I.M.v.d.B.); and Department of Ultrasound and Interventions, Philips Research North America, Briarcliff Manor, NY (M.L.)
| | - Jae Ho Sohn
- From the Russell H. Morgan Department of Radiology and Radiological Science, Division of Vascular and Interventional Radiology, The Johns Hopkins Hospital, 1800 Orleans St, Sheikh Zayed Tower, Suite 7203, Baltimore, MD 21287 (R.E.S., J.C., S.S., R.D., J.H.S., J.F.H.G.); Philips Healthcare, Best, the Netherlands (P.W., A.R., I.M.v.d.B.); and Department of Ultrasound and Interventions, Philips Research North America, Briarcliff Manor, NY (M.L.)
| | - Alessandro Radaelli
- From the Russell H. Morgan Department of Radiology and Radiological Science, Division of Vascular and Interventional Radiology, The Johns Hopkins Hospital, 1800 Orleans St, Sheikh Zayed Tower, Suite 7203, Baltimore, MD 21287 (R.E.S., J.C., S.S., R.D., J.H.S., J.F.H.G.); Philips Healthcare, Best, the Netherlands (P.W., A.R., I.M.v.d.B.); and Department of Ultrasound and Interventions, Philips Research North America, Briarcliff Manor, NY (M.L.)
| | - Imramsjah Martin van der Bom
- From the Russell H. Morgan Department of Radiology and Radiological Science, Division of Vascular and Interventional Radiology, The Johns Hopkins Hospital, 1800 Orleans St, Sheikh Zayed Tower, Suite 7203, Baltimore, MD 21287 (R.E.S., J.C., S.S., R.D., J.H.S., J.F.H.G.); Philips Healthcare, Best, the Netherlands (P.W., A.R., I.M.v.d.B.); and Department of Ultrasound and Interventions, Philips Research North America, Briarcliff Manor, NY (M.L.)
| | - Jean-François H Geschwind
- From the Russell H. Morgan Department of Radiology and Radiological Science, Division of Vascular and Interventional Radiology, The Johns Hopkins Hospital, 1800 Orleans St, Sheikh Zayed Tower, Suite 7203, Baltimore, MD 21287 (R.E.S., J.C., S.S., R.D., J.H.S., J.F.H.G.); Philips Healthcare, Best, the Netherlands (P.W., A.R., I.M.v.d.B.); and Department of Ultrasound and Interventions, Philips Research North America, Briarcliff Manor, NY (M.L.)
| | - MingDe Lin
- From the Russell H. Morgan Department of Radiology and Radiological Science, Division of Vascular and Interventional Radiology, The Johns Hopkins Hospital, 1800 Orleans St, Sheikh Zayed Tower, Suite 7203, Baltimore, MD 21287 (R.E.S., J.C., S.S., R.D., J.H.S., J.F.H.G.); Philips Healthcare, Best, the Netherlands (P.W., A.R., I.M.v.d.B.); and Department of Ultrasound and Interventions, Philips Research North America, Briarcliff Manor, NY (M.L.)
| |
Collapse
|