1
|
Park J, Jung JI, Han K, Chang S. Deep Learning-Based Contrast Boosting in Low-Contrast Media Pre-TAVR CT Imaging. Can Assoc Radiol J 2025:8465371251322054. [PMID: 40071690 DOI: 10.1177/08465371251322054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/18/2025] Open
Abstract
Purpose: This study investigates the impact of deep learning-based contrast boosting (DL-CB) on image quality and measurement reliability in low-contrast media (low-CM) CT for pre-transcatheter aortic valve replacement (TAVR) assessment. Methods: This retrospective study included TAVR candidates with renal dysfunction who underwent low-CM (30-mL: 15-mL bolus of contrast followed by 50-mL of 30% iomeprol solution) pre-TAVR CT between April and December 2023, along with matched standard-CM controls (n = 68). Low-CM images were reconstructed as conventional, 50-keV, and DL-CB images. Qualitative and quantitative image quality were compared among image sets. The aortic annulus was measured by 2 independent readers on low-CM CT images, and interobserver reliability was assessed. Results: DL-CB significantly improved contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) compared to conventional and 50-keV images (CNR: 12.5-13.4, 18-19.8, and 21.9-24; SNR: 10.8-15.5, 10.7-15.5, and 16.8-26.7 on conventional, 50-keV, and DL-CB images, respectively; P < .001). DL-CB achieved comparable CNR (21.9-24 vs 27-27.7, P = .39-.61) and comparable to slightly higher SNR (16.8-26.7 vs 15.7-20.2, P = .003-.80) to standard-CM images. For aortic annular measurement, DL-CB demonstrated high interobserver reliability, with an intraclass correlation coefficient (ICC) of .96 and small mean differences (area: 0.01 cm², limits of agreement [LoA]: -0.52 to 0.55 cm²; perimeter: 0.02 mm, LoA: -4.49 to 4.53 mm). Conclusions: DL-CB improves image quality and provides high measurement reliability in low-CM CT for pre-TAVR assessment in patients with renal dysfunction, without requiring dual-energy CT.
Collapse
Affiliation(s)
- Jeaneun Park
- Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Jung Im Jung
- Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Kyunghwa Han
- Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Suyon Chang
- Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| |
Collapse
|
2
|
Imrek AK, Hızal M, Yılmazsoy Y, Coşgun Z. The use of dual and triple rule-out computerized tomography angiography by using diagnostic low-dose contrast material and radiation in acute chest pain. Acta Radiol 2025; 66:125-133. [PMID: 39726166 DOI: 10.1177/02841851241298900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2024]
Abstract
BACKGROUND Triple rule-out computed tomography angiography (CTA) provides imaging of the coronary arteries, pulmonary arteries, and thoracic aorta filled with contrast material (CM) to exclude or diagnose the pathologies of these three systems. Although dual rule-out adapted to exclude aortic and pulmonary pathologies. Iodinated CM may result in contrast-induced nephropathy, which lengthens hospital stay. PURPOSE To compare image quality of dual/triple rule-out CTA by reducing the radiation dose by using relatively high mAs with less contrast material and low kilovoltage without affecting the diagnostic value. METHODS We acquired standard dual/triple rule-out CTA 120 kilovoltage peak (kVp) with 95 mL contrast material. The low-dose group acquired 80 Kvp with total 60 contrast material. There were 91 patients in the standard-dose group and 88 patients in the low-dose group. RESULTS Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated separately. There was no significant difference in CNR values between the two groups in the aorta and pulmonary and coronary arteries; however, a significant difference was found in SNR values. In subjective image quality evaluation, no significant difference was found between the standard- and low-dose patients. The radiation dose was reduced by 63.80% and the contrast material by 31.5% in the low-dose group in comparison to the standard dose. CONCLUSION Our study showed that dual/triple rule-out CTA can be performed with low-dose radiation and low-volume contrast material. Low-dose CTA may be preferred in emergencies situations that patients with borderline renal function tests or the risk group.
Collapse
Affiliation(s)
- Ahmet Kerem Imrek
- Department of Radiology, Bolu Abant Izzet Baysal University Faculty of Medicine Hospital, Bolu, Turkey
| | - Mustafa Hızal
- Department of Radiology, Bolu Abant Izzet Baysal University Faculty of Medicine Hospital, Bolu, Turkey
| | - Yunus Yılmazsoy
- Department of Radiology, Bolu Abant Izzet Baysal University Faculty of Medicine Hospital, Bolu, Turkey
| | - Zeliha Coşgun
- Department of Radiology, Bolu Abant Izzet Baysal University Faculty of Medicine Hospital, Bolu, Turkey
| |
Collapse
|
3
|
Masuda T, Nakaura T, Higaki T, Funama Y, Matsumoto Y, Sato T, Okimoto T, Arao K, Imaizumi H, Arao S, Ono A, Hiratsuka J, Awai K. Using Patient-Specific Contrast Enhancement Optimizer Simulation Software During the Transcatheter Aortic Valve Implantation-Computed Tomography Angiography in Patients With Aortic Stenosis. J Comput Assist Tomogr 2024; 48:759-762. [PMID: 38595080 DOI: 10.1097/rct.0000000000001603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/11/2024]
Abstract
OBJECTIVES This study assessed whether patient-specific contrast enhancement optimizer simulation software (p-COP) can reduce the contrast material (CM) dose compared with the conventional body weight (BW)-tailored scan protocol during transcatheter aortic valve implantation-computed tomography angiography (TAVI-CTA) in patients with aortic stenosis. METHODS We used the CM injection protocol selected by the p-COP in group A (n = 30). p-COP uses an algorithm that concerns data on an individual patient's cardiac output. Group B (n = 30) was assigned to the conventional BW-tailored CM injection protocol group. We compared the CM dose, CM amount, injection rate, and computed tomography (CT) values in the abdominal aorta between the 2 groups and classified them as acceptable (>280 Hounsfield units (HU)) or unacceptable (<279 HU) based on the optimal CT value and visualization scores for TAVI-CTA. We used the Mann-Whitney U test to compare patient characteristics and assess the interpatient variability of subjects in both groups. RESULTS Group A received 56.2 mL CM and 2.6 mL/s of injection, whereas group B received 76.9 mL CM and 3.4 mL/s of injection ( P < 0.01). The CT value for the abdominal aorta at the celiac level was 287.0 HU in group A and 301.7HU in group B ( P = 0.46). The acceptable (>280 HU) and unacceptable (<280 HU) CT value rates were 22 and 8 patients in group A and 24 and 6 patients in group B, respectively ( P = 0.76). We observed no significant differences in the visualization scores between groups A and B (visualization score = 3, P = 0.71). CONCLUSION The utilization of p-COP may decrease the CM dosage and injection rate by approximately 30% in individuals with aortic stenosis compared with the body-weight-tailored scan protocol during TAVI-CTA.
Collapse
Affiliation(s)
- Takanori Masuda
- From the Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan
| | - Toru Higaki
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan
| | - Yoshinori Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - Yoriaki Matsumoto
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan
| | - Tomoyasu Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Naka-ku, Hiroshima, Japan
| | - Tomokazu Okimoto
- Department of Cardiovascular Internal Medicine, Edogawa Hospital, Tokyo, Japan
| | - Keiko Arao
- From the Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan
| | - Hiromasa Imaizumi
- From the Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan
| | - Shinichi Arao
- From the Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan
| | - Atsushi Ono
- From the Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan
| | - Junichi Hiratsuka
- From the Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan
| | - Kazuo Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
4
|
Chang S, Jung JI, Beck KS, Chang K, Kim Y, Han K. Diagnostic Efficacy and Safety of Low-Contrast-Dose Dual-Energy CT in Patients With Renal Impairment Undergoing Transcatheter Aortic Valve Replacement. Korean J Radiol 2024; 25:634-643. [PMID: 38942457 PMCID: PMC11214918 DOI: 10.3348/kjr.2023.1207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2023] [Revised: 05/09/2024] [Accepted: 05/10/2024] [Indexed: 06/30/2024] Open
Abstract
OBJECTIVE This study aimed to evaluate the diagnostic efficacy and safety of low-contrast-dose, dual-source dual-energy CT before transcatheter aortic valve replacement (TAVR) in patients with compromised renal function. MATERIALS AND METHODS A total of 54 consecutive patients (female:male, 26:38; 81.9 ± 7.3 years) with reduced renal function underwent pre-TAVR dual-energy CT with a 30-mL contrast agent between June 2022 and March 2023. Monochromatic (40- and 50-keV) and conventional (120-kVp) images were reconstructed and analyzed. The subjective quality score, vascular attenuation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were compared among the imaging techniques using the Friedman test and post-hoc analysis. Interobserver reliability for aortic annular measurement was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. The procedural outcomes and incidence of post-contrast acute kidney injury (AKI) were assessed. RESULTS Monochromatic images achieved diagnostic quality in all patients. The 50-keV images achieved superior vascular attenuation and CNR (P < 0.001 in all) while maintaining a similar SNR compared to conventional CT. For aortic annular measurement, the 50-keV images showed higher interobserver reliability compared to conventional CT: ICC, 0.98 vs. 0.90 for area and 0.97 vs. 0.95 for perimeter; 95% limits of agreement width, 0.63 cm² vs. 0.92 cm² for area and 5.78 mm vs. 8.50 mm for perimeter. The size of the implanted device matched CT-measured values in all patients, achieving a procedural success rate of 92.6%. No patient experienced a serum creatinine increase of ≥ 1.5 times baseline in the 48-72 hours following CT. However, one patient had a procedural delay due to gradual renal function deterioration. CONCLUSION Low-contrast-dose imaging with 50-keV reconstruction enables precise pre-TAVR evaluation with improved image quality and minimal risk of post-contrast AKI. This approach may be an effective and safe option for pre-TAVR evaluation in patients with compromised renal function.
Collapse
Affiliation(s)
- Suyon Chang
- Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Jung Im Jung
- Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
| | - Kyongmin Sarah Beck
- Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Kiyuk Chang
- Division of Cardiology, Department of Internal Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Yaeni Kim
- Division of Nephrology, Department of Internal Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Kyunghwa Han
- Department of Radiology, Research Institute of Radiological Science, and Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
5
|
Langenbach IL, Langenbach MC, Mayrhofer T, Foldyna B, Maintz D, Klein K, Wienemann H, Krug KB, Hellmich M, Adam M, Naehle CP. Reduction of contrast medium for transcatheter aortic valve replacement planning using a spectral detector CT: a prospective clinical trial. Eur Radiol 2024; 34:4089-4099. [PMID: 37979008 PMCID: PMC11166752 DOI: 10.1007/s00330-023-10403-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Revised: 08/25/2023] [Accepted: 09/17/2023] [Indexed: 11/19/2023]
Abstract
INTRODUCTION This study investigated the use of dual-energy spectral detector computed tomography (CT) and virtual monoenergetic imaging (VMI) reconstructions in pre-interventional transcatheter aortic valve replacement (TAVR) planning. We aimed to determine the minimum required contrast medium (CM) amount to maintain diagnostic CT imaging quality for TAVR planning. METHODS In this prospective clinical trial, TAVR candidates received a standardized dual-layer spectral detector CT protocol. The CM amount (Iohexol 350 mg iodine/mL, standardized flow rate 3 mL/s) was reduced systematically after 15 patients by 10 mL, starting at 60 mL (institutional standard). We evaluated standard, and 40- and 60-keV VMI reconstructions. For image quality, we measured signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and diameters in multiple vessel sections (i.e., aortic annulus: diameter, perimeter, area; aorta/arteries: minimal diameter). Mixed regression models (MRM), including interaction terms and clinical characteristics, were used for comparison. RESULTS Sixty consecutive patients (mean age, 79.4 ± 7.5 years; 28 females, 46.7%) were included. In pre-TAVR CT, the CM reduction to 40 mL is possible without affecting the image quality (MRM: SNR: -1.1, p = 0.726; CNR: 0.0, p = 0.999). VMI 40-keV reconstructions showed better results than standard reconstructions with significantly higher SNR (+ 6.04, p < 0.001). Reduction to 30 mL CM resulted in a significant loss of quality (MRM: SNR: -12.9, p < 0.001; CNR: -13.9, p < 0.001), regardless of the reconstruction. Across the reconstructions, we observed no differences in the metric evaluation (p > 0.914). CONCLUSION Among TAVR candidates undergoing pre-interventional CT at a dual-layer spectral detector system, applying 40 mL CM is sufficient to maintain diagnostic image quality. VMI 40-keV reconstructions improve the vessel attenuation and are recommended for evaluation. CLINICAL RELEVANCE STATEMENT Contrast medium reduction to 40 mL in pre-interventional transcatheter aortic valve replacement CT using dual-energy CT maintains image quality, while 40-keV virtual monoenergetic imaging reconstructions enhance vessel attenuation. These results offer valuable recommendations for interventional transcatheter aortic valve replacement evaluation and potentially improve nephroprotection in patients with compromised renal function. KEY POINTS • Patients undergoing transcatheter aortic valve replacement (TAVR), requiring pre-interventional CT, are often multimorbid with impaired renal function. • Using a spectral detector dual-layer CT, contrast medium reduction to 40 mL is feasible, maintaining diagnostic image quality. • The additional application of virtual monoenergetic image reconstructions with 40 keV improves vessel attenuation significantly in clinical practice.
Collapse
Affiliation(s)
- Isabel L Langenbach
- Cardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA, 02114, USA.
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany.
| | - Marcel C Langenbach
- Cardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA, 02114, USA
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany
| | - Thomas Mayrhofer
- Cardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA, 02114, USA
- School of Business Studies, Stralsund University of Applied Sciences, Stralsund, Germany
| | - Borek Foldyna
- Cardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA, 02114, USA
| | - David Maintz
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany
| | - Konstantin Klein
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany
| | - Hendrik Wienemann
- Clinic III for Internal Medicine, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany
| | - Kathrin B Krug
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany
| | - Martin Hellmich
- Institute of Medical Statistics and Computational Biology, Medical Faculty, University of Cologne, Cologne, Germany
| | - Matti Adam
- Clinic III for Internal Medicine, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany
| | | |
Collapse
|
6
|
Schuppert C, Salatzki J, André F, Riffel J, Mangold DL, Melzig C, Hagar MT, Kauczor HU, Weber TF, Rengier F, Do TD. Feasibility of Reduced Iodine Loads for Vascular Assessment Prior to Transcatheter Aortic Valve Implantation (TAVI) Using Spectral Detector CT. Diagnostics (Basel) 2024; 14:879. [PMID: 38732294 PMCID: PMC11082960 DOI: 10.3390/diagnostics14090879] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 03/31/2024] [Accepted: 04/11/2024] [Indexed: 05/13/2024] Open
Abstract
Reduced iodine loads for computed tomography (CT)-based vascular assessment prior to transcatheter aortic valve implantation (TAVI) may be feasible in conjunction with a spectral detector CT scanner. This prospective single-center study considered 100 consecutive patients clinically referred for pre-TAVI CT. They were examined on a dual-layer detector CT scanner to obtain an ECG-gated cardiac scan and a non-ECG-gated aortoiliofemoral scan. Either a standard contrast media (SCM) protocol using 80 mL Iohexol 350 mgI/mL (iodine load: 28 gI) or a body-mass-index adjusted reduced contrast media (RCM) protocol using 40-70 mL Iohexol 350 mgI/mL (iodine load: 14-24.5 gI) were employed. Conventional images and virtual monoenergetic images at 40-80 keV were reconstructed. A threshold of 250 HU was set for sufficient attenuation along the arterial access pathway. A qualitative assessment used a five-point Likert scale. Sufficient attenuation in the thoracic aorta was observed for all patients in both groups using conventional images. In the abdominal, iliac, and femoral segments, sufficient attenuation was observed for the majority of patients when using virtual monoenergetic images (SCM: 96-100% of patients, RCM: 88-94%) without statistical difference between both groups. Segments with attenuation measurements below the threshold remained qualitatively assessable as well. Likert scores were 'excellent' for virtual monoenergetic images 50 keV and 55 keV in both groups (RCM: 1.2-1.4, SCM: 1.2-1.3). With diagnostic image quality maintained, it can be concluded that reduced iodine loads of 14-24.5 gI are feasible for pre-TAVI vascular assessment on a spectral detector CT scanner.
Collapse
Affiliation(s)
- Christopher Schuppert
- Department of Diagnostic and Interventional Radiology, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg, 79106 Freiburg im Breisgau, Germany
- Clinic of Diagnostic and Interventional Radiology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Janek Salatzki
- Clinic of Cardiology, Angiology and Pneumology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Florian André
- Clinic of Cardiology, Angiology and Pneumology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Johannes Riffel
- Department of Cardiology and Angiology, Robert Bosch Hospital, 70376 Stuttgart, Germany
| | - David L. Mangold
- Clinic of Diagnostic and Interventional Radiology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Claudius Melzig
- Clinic of Diagnostic and Interventional Radiology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Muhammad Taha Hagar
- Department of Diagnostic and Interventional Radiology, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg, 79106 Freiburg im Breisgau, Germany
| | - Hans-Ulrich Kauczor
- Clinic of Diagnostic and Interventional Radiology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Tim F. Weber
- Clinic of Diagnostic and Interventional Radiology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Fabian Rengier
- Clinic of Diagnostic and Interventional Radiology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Thuy D. Do
- Clinic of Diagnostic and Interventional Radiology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| |
Collapse
|
7
|
D'Angelo T, Lanzafame LRM, Liguori C, Mantini C, Russo V, Palumbo P, Scalera GB, Iozzelli A, Borghesi A, Matta G, Greco F, Garretto V, Danti M, Iezzi R, Francone M. Pre-TAVI imaging: an Italian survey by the CT PRotocol optimization (CT-PRO) group. Int J Cardiovasc Imaging 2024; 40:831-839. [PMID: 38263535 PMCID: PMC11052815 DOI: 10.1007/s10554-024-03052-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2023] [Accepted: 01/07/2024] [Indexed: 01/25/2024]
Abstract
PURPOSE The purpose of this survey was to evaluate the current state-of-art of pre-TAVI imaging in a large radiological professional community. METHODS Between December 2022 and January 2023 all members of the Italian Society of Medical and Interventional Radiology (SIRM) were invited by the CT PRotocol Optimization group (CT-PRO group) to complete an online 24-item questionnaire about pre-TAVI imaging. RESULTS 557 SIRM members participated in the survey. The greatest part of respondents were consultant radiologists employed in public hospitals and 84% claimed to routinely perform pre-TAVI imaging at their institutions. The most widespread acquisition protocol consisted of an ECG-gated CT angiography (CTA) scan of the aortic root and heart followed by a non-ECG-synchronized CTA of the thorax, abdomen, and pelvis. Contrast agent administration was generally tailored on the patient's body weight with a preference for using high concentration contrast media. The reports were commonly written by radiologists with expertise in cardiovascular imaging, and included all the measurements suggested by current guidelines for adequate pre-procedural planning. About 60% of the subjects affirmed that the Heart Team is present at their institutions, however only 7% of the respondents regularly attended the multidisciplinary meetings. CONCLUSIONS This survey defines the current pre-TAVI imaging practice in a large radiological professional community. Interestingly, despite the majority of radiologists follow the current guidelines regarding acquisition and reporting of pre-TAVI imaging studies, there is still a noteworthy absence from multidisciplinary meetings and from the Heart Team.
Collapse
Affiliation(s)
- Tommaso D'Angelo
- Unit of Diagnostic and Interventional Imaging, Department BIOMORF, University of Messina, Via Consolare Valeria 1, Messina, 98100, Italy.
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands.
| | - Ludovica R M Lanzafame
- Unit of Diagnostic and Interventional Imaging, Department BIOMORF, University of Messina, Via Consolare Valeria 1, Messina, 98100, Italy
| | - Carlo Liguori
- Radiology Unit, Ospedale del Mare, ASL NA1 Centro, Napoli, Italy
| | - Cesare Mantini
- Department of Neuroscience, Imaging and Clinical Sciences, "Gabriele D'Annunzio" University of Chieti-Pescara, Chieti, Italy
| | - Vincenzo Russo
- Pediatric and Adult CardioThoracic and Vascular, Oncohematologic and Emergency Radiology Unit, Radiology Department IRCCS, Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Pierpaolo Palumbo
- Department of Diagnostic Imaging, Area of Cardiovascular and Interventional Imaging, Abruzzo Health Unit 1, L'Aquila, Italy
| | - Giovanni B Scalera
- Unit of Diagnostic Imaging, Department of Medicine and Surgery, Santa Maria della Misericordia Hospital, University of Perugia, Perugia, Italy
| | | | - Andrea Borghesi
- Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, ASST Spedali Civili of Brescia, Piazzale Spedali Civili, 1, Brescia, I - 25123, Italy
| | - Gildo Matta
- Department of Radiology, Azienda Ospedaliera "G. Brotzu", Cagliari, Italy
| | - Fabio Greco
- Department of Radiology, "University Hospitals Bristol and Weston Foundation Trust", Bristol, UK
| | - Valeria Garretto
- Diagnostic Radiology Unit Department, CAST - Policlinico - San Marco Hospital University, Catania, Italy
| | | | - Roberto Iezzi
- Unit of Diagnostic and Interventional Imaging, Department of Diagnostic Imaging, Radiation Therapy and Hematology, IRCCS Policlinico "A. Gemelli", Roma, Italy
- Unit of Radiology, Università Cattolica del Sacro Cuore, Roma, Italy
| | - Marco Francone
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy
- IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy
| |
Collapse
|
8
|
Kitahara H, Kumamaru H, Kohsaka S, Yamashita D, Kanda T, Matsuura K, Shimamura K, Matsumiya G, Kobayashi Y. Clinical Outcomes of Urgent or Emergency Transcatheter Aortic Valve Implantation - Insights From the Nationwide Registry of Japan Transcatheter Valve Therapies. Circ J 2024; 88:439-447. [PMID: 36575039 DOI: 10.1253/circj.cj-22-0536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
BACKGROUND Limited data are available for clinical outcomes in patients who underwent urgent or emergency transcatheter aortic valve implantation (TAVI). This study investigated in-hospital and 1-year outcomes and explored prognostic covariates in urgent/emergency TAVI using nationwide registry data. METHODS AND RESULTS Among 26,775 patients who underwent TAVI between August 2013 and December 2019, 25,495 with 1-year follow-up information were analyzed in this study. Baseline and procedural characteristics, as well as clinical adverse events, were compared between the urgent/emergency and elective TAVI groups. The primary outcome was all-cause mortality within 1 year after TAVI. Multivariable Cox regression models were constructed to identify independent predictors after urgent or emergency TAVI. Urgent or emergency TAVI was performed in 578 (2.3%) patients. The Society of Thoracic Surgeons score was significantly higher in the urgent/emergency than elective TAVI group (13.3% vs. 6.0%; P<0.001). Device success rate was comparable between the 2 groups. All-cause death-free survival within 1 year was lower in the urgent/emergency than elective TAVI group (77.2% vs. 92.2%; log rank P<0.001). Malignancy, albumin and creatinine concentrations, ejection fraction, and mean pressure gradient were associated with 1-year mortality in the urgent/emergency TAVI group. CONCLUSIONS Despite higher surgical risk and more comorbidities, the procedure was successfully performed in patients undergoing urgent/emergency TAVI, although it should be noted that prognosis was worse than for elective TAVI.
Collapse
Affiliation(s)
- Hideki Kitahara
- Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine
| | - Hiraku Kumamaru
- Department of Healthcare Quality Assessment, Graduate School of Medicine, The University of Tokyo
| | - Shun Kohsaka
- Department of Cardiology, Keio University School of Medicine
| | - Daichi Yamashita
- Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine
| | - Tomoyoshi Kanda
- Department of Cardiovascular Surgery, Chiba University Graduate School of Medicine
| | - Kaoru Matsuura
- Department of Cardiovascular Surgery, Chiba University Graduate School of Medicine
| | - Kazuo Shimamura
- Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine
| | - Goro Matsumiya
- Department of Cardiovascular Surgery, Chiba University Graduate School of Medicine
| | - Yoshio Kobayashi
- Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine
| |
Collapse
|
9
|
Intravenous Contrast Material for Cardiac Computed Tomography: Results From the Open-label Multicenter, Multivendor Italian Registry of Contrast Material Use in Cardiac Computed Tomography. J Thorac Imaging 2023; 38:128-135. [PMID: 36821381 DOI: 10.1097/rti.0000000000000644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE The Italian Registry of Contrast Material use in Cardiac Computed Tomography (iRCM-CCT) is a multicenter, multivendor, observational study on the use of contrast media (CM) in patients undergoing cardiac computed tomography (CCT). The aim of iRCM-CCT is to assess image quality and safety profile of intravenous CM compounds. MATERIALS AND METHODS iRCM-CCT enrolled 1842 consecutive patients undergoing CCT (≥50 per site) at 20 cluster sites with the indication of suspected coronary artery disease. Demographic characteristics, CCT, and CM protocols, clinical indications, safety markers, radiation dose reports, qualitative (ie, poor vascular enhancement) and quantitative (ie, HU attenuation values) image parameters were recorded. A centralized coordinating center collected and assessed all image parameters. RESULTS The cohort included 891 men and 951 women (age: 63±14 y, body mass index: 26±4 kg/m2) studied with ≥64 detector rows computed tomography scanners and different iodinated intravenous CM protocols and compounds (iodixanol, iopamidol, iohexol, iobitridol, iopromide, and iomeprol). The following vascular attenuation was reported: 504±147 HU in the aorta, 451±146 HU in the right coronary artery, 474±146 HU in the left main, 451±146 HU in the left anterior descending artery, and 441±149 HU in the circumflex artery. In 4% of cases the image quality was not satisfactory due to poor enhancement. The following adverse reactions to CM were recorded: 6 (0.3%) extravasations and 17 (0.9%) reactions (11 mild, 4 moderate, 2 severe). CONCLUSIONS In a multicenter registry on CM use during CCT the prevalence of CM-related adverse reactions was very low. The appropriate use of CM is a major determinant of image quality.
Collapse
|
10
|
Gallo GS, Caruso C, Iannazzo E, Cannataci C, Gerasia R, Tafaro C, Gentile G, Mamone G, Caruso S, Marrone G, Gandolfo C, Miraglia R. Feasibility of Ultra-Low Volume Contrast-Saline Mixture Injection With Dual-Flow Technique in a Pre-TAVI Computed Tomography Angiography. Heart Lung Circ 2023; 32:525-534. [PMID: 36804708 DOI: 10.1016/j.hlc.2022.12.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Revised: 12/10/2022] [Accepted: 12/16/2022] [Indexed: 02/19/2023]
Abstract
BACKGROUND To explore the feasibility and image quality of ultra-low volume contrast-saline mixture injection with dual-flow injection technique in a computed tomography angiography (CTA) protocol in patients scheduled for transcatheter aortic valve implantation (TAVI). METHODS Forty (40) TAVI candidates underwent investigation with CTA using a third-generation dual-source CT scanner between September and November 2020. Different volumes of a monophasic contrast-saline mixture at an 80:20 ratio were administered at an infusion rate of 3 mL/s in 20 patients (group A). The injected volume was based on patient body mass index (BMI): 50 mL if BMI <29 kg/m2 and 63 mL if BMI >29 kg/m2. The other 20 patients (group B)-the control cases-received a total of 65 mL of contrast medium (CM), in multiphasic injections at different flow rates, followed by 10 mL of saline. The images that were obtained were prospectively evaluated for image quality, vessel attenuation (HU), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and estimated radiation dose. RESULTS Image quality of the aortic root and ilio-femoral vessels was diagnostic in all patients. Vascular attenuation was >200 HU and CNR >3 at any vessel level. CONCLUSIONS Data from this study suggest that a monophasic ultra-low volume contrast-saline mixture injection with a dual-flow technique can provide clear visualisation of the aortic root and ilio-femoral vessels in pre-TAVI CTA, which is comparable with a standard multiphasic volume injection protocol.
Collapse
Affiliation(s)
- Giuseppe S Gallo
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy.
| | - Calogero Caruso
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| | - Erica Iannazzo
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| | | | - Roberta Gerasia
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| | - Corrado Tafaro
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| | - Giovanni Gentile
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| | - Giuseppe Mamone
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| | - Settimo Caruso
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| | - Gianluca Marrone
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| | - Caterina Gandolfo
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| | - Roberto Miraglia
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| |
Collapse
|
11
|
Heinrich A, Yücel S, Böttcher B, Öner A, Manzke M, Klemenz AC, Weber MA, Meinel FG. Improved image quality in transcatheter aortic valve implantation planning CT using deep learning-based image reconstruction. Quant Imaging Med Surg 2023; 13:970-981. [PMID: 36819291 PMCID: PMC9929406 DOI: 10.21037/qims-22-639] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Accepted: 11/10/2022] [Indexed: 12/24/2022]
Abstract
Background This study aims to evaluate the impact of a novel deep learning-based image reconstruction (DLIR) algorithm on the image quality in computed tomographic angiography (CTA) for pre-interventional planning of transcatheter aortic valve implantation (TAVI). Methods We analyzed 50 consecutive patients (median age 80 years, 25 men) who underwent TAVI planning CT on a 256-dectector-row CT. Images were reconstructed with adaptive statistical iterative reconstruction V (ASIR-V) and DLIR. Intravascular image noise, edge sharpness, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were quantified for ascending aorta, descending aorta, abdominal aorta and iliac arteries. Two readers (one radiologist and one interventional cardiologist) scored task-specific subjective image quality on a five-point scale. Results DLIR significantly reduced median image noise by 29-57% at all anatomical locations (all P<0.001). Accordingly, median SNR improved by 44-133% (all P<0.001) and median CNR improved by 44-125% (all P<0.001). DLIR significantly improved subjective image quality for all four pre-specified TAVI-specific tasks (measuring the annulus, assessing valve morphology and calcifications, the coronary ostia, and the suitability of the aorto-iliac access route) for both the radiologist and the interventional cardiologist (P≤0.001). Measurements of the aortic annulus circumference, area and diameter did not differ between ASIR-V and DLIR reconstructions (all P>0.05). Conclusions DLIR significantly improves objective and subjective image quality in TAVI planning CT compared to a state-of-the-art iterative reconstruction without affecting measurements of the aortic annulus. This may provide an opportunity for further reductions in contrast medium volume in this population.
Collapse
Affiliation(s)
- Andra Heinrich
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Rostock, Germany
| | - Seyrani Yücel
- Department of Internal Medicine, Division of Cardiology, University Medical Centre Rostock, Rostock, Germany
| | - Benjamin Böttcher
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Rostock, Germany
| | - Alper Öner
- Department of Internal Medicine, Division of Cardiology, University Medical Centre Rostock, Rostock, Germany
| | - Mathias Manzke
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Rostock, Germany
| | - Ann-Christin Klemenz
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Rostock, Germany
| | - Marc-André Weber
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Rostock, Germany
| | - Felix G. Meinel
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Rostock, Germany
| |
Collapse
|
12
|
Lacy SC, Benjamin MM, Osman M, Syed MA, Kinno M. Low Contrast and Low kV CTA Before Transcatheter Aortic Valve Replacement: A Systematic Review. J Cardiovasc Imaging 2023; 31:108-115. [PMID: 37096677 PMCID: PMC10133812 DOI: 10.4250/jcvi.2022.0108] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Revised: 12/23/2022] [Accepted: 01/03/2023] [Indexed: 02/22/2023] Open
Abstract
BACKGROUND Minimizing contrast dose and radiation exposure while maintaining image quality during computed tomography angiography (CTA) for transcatheter aortic valve replacement (TAVR) is desirable, but not well established. This systematic review compares image quality for low contrast and low kV CTA versus conventional CTA in patients with aortic stenosis undergoing TAVR planning. METHODS We performed a systematic literature review to identify clinical studies comparing imaging strategies for patients with aortic stenosis undergoing TAVR planning. The primary outcomes of image quality as assessed by the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were reported as random effects mean difference with 95% confidence interval (CI). RESULTS We included 6 studies reporting on 353 patients. There was no difference in cardiac SNR (mean difference, -1.42; 95% CI, -5.71 to 2.88; p = 0.52), cardiac CNR (mean difference, -3.83; 95% CI, -9.98 to 2.32; p = 0.22), aortic SNR (mean difference, -0.23; 95% CI, -7.83 to 7.37; p = 0.95), aortic CNR (mean difference, -3.95; 95% CI, -12.03 to 4.13; p = 0.34), and ileofemoral SNR (mean difference, -6.09; 95% CI, -13.80 to 1.62; p = 0.12) between the low dose and conventional protocols. There was a difference in ileofemoral CNR between the low dose and conventional protocols with a mean difference of -9.26 (95% CI, -15.06 to -3.46; p = 0.002). Overall, subjective image quality was similar between the 2 protocols. CONCLUSIONS This systematic review suggests that low contrast and low kV CTA for TAVR planning provides similar image quality to conventional CTA.
Collapse
Affiliation(s)
- Spencer C. Lacy
- Department of Internal Medicine, Loyola University Medical Center, Maywood, IL, USA
| | - Mina M. Benjamin
- Division of Cardiovascular Medicine, Loyola University Medical Center, Maywood, IL, USA
| | - Mohammed Osman
- Knight & Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA
| | - Mushabbar A. Syed
- Division of Cardiovascular Medicine, Loyola University Medical Center, Maywood, IL, USA
| | - Menhel Kinno
- Division of Cardiovascular Medicine, Loyola University Medical Center, Maywood, IL, USA
| |
Collapse
|
13
|
Komber HMEI, Neumann S, Paull J, Andrade MG, Lyen SM, Manghat NE, Hamilton MCK. A quality-improvement project to enhance systemic arterial contrast opacification in CT for trans-catheter aortic valve implantation. Clin Radiol 2022; 77:e697-e704. [PMID: 35717408 DOI: 10.1016/j.crad.2022.05.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Revised: 05/13/2022] [Accepted: 05/17/2022] [Indexed: 11/03/2022]
Abstract
AIM To assess improvement in arterial opacification by optimising the contrast medium dosing protocol for computed tomography (CT) prior to trans-catheter aortic valve implantation (TAVI). MATERIALS AND METHODS A wide variation in arterial opacification was observed in the initial CT TAVI protocol (standard protocol). The practice was optimised by considering the time required for the examination and optimising contrast medium flux. This became the optimised protocol with a 30-second contrast medium bolus of iodine flux 15-19 mg iodine/kg body weight/second (mg/kg/s). Attenuation (mean HU) in (a) the ascending aorta (gated systolic acquisition) and (b) the ascending, descending thoracic (at carina), infra-renal abdominal aorta, and right common iliac artery (non-gated acquisition) was measured. Thirty-one sequential optimised examinations were compared to 31 prior standard protocol examinations. RESULTS There was no difference between the standard and optimised groups regarding age, sex, weight, body mass index (BMI), or voltage. The mean bolus durations were 24.9±4.4 seconds for the standard and 30±0.3 seconds for the optimised protocols (p<0.001). Although there was no difference in the attenuation in the gated ascending aorta (p>0.99), there was improvement at all other anatomical points in the non-gated examinations of the optimised protocol (p<0.002). CONCLUSION Optimising contrast medium flux and matching bolus duration to the CT technology dramatically improves the vascular access component of TAVI planning and provides a reliable method to achieve objectively enhanced arterial opacification. This work highlights how to obtain good arterial contrast medium opacification in haemodynamically fragile patients without excessive contrast medium volumes.
Collapse
Affiliation(s)
- H M E I Komber
- Department of Radiology, University Hospitals Bristol and Weston NHS Foundation Trust, Upper Maudlin Street, Bristol BS2 8HW, UK.
| | - S Neumann
- Faculty of Life Sciences, School of Physiology, Pharmacology and Neuroscience, University of Bristol, Senate House, Tyndall Ave, Bristol BS8 1TH, UK
| | - J Paull
- Department of Radiology, University Hospitals Bristol and Weston NHS Foundation Trust, Upper Maudlin Street, Bristol BS2 8HW, UK
| | - M Gesteira Andrade
- Department of Radiology, University Hospitals Bristol and Weston NHS Foundation Trust, Upper Maudlin Street, Bristol BS2 8HW, UK
| | - S M Lyen
- Department of Radiology, University Hospitals Bristol and Weston NHS Foundation Trust, Upper Maudlin Street, Bristol BS2 8HW, UK
| | - N E Manghat
- Department of Radiology, University Hospitals Bristol and Weston NHS Foundation Trust, Upper Maudlin Street, Bristol BS2 8HW, UK
| | - M C K Hamilton
- Department of Radiology, University Hospitals Bristol and Weston NHS Foundation Trust, Upper Maudlin Street, Bristol BS2 8HW, UK
| |
Collapse
|
14
|
Bhatia M, Kumar P, Maity P, Arora N. Computed Tomographic Assessment before Transcatheter Aortic and Mitral Valve Replacement. JOURNAL OF THE INDIAN ACADEMY OF ECHOCARDIOGRAPHY & CARDIOVASCULAR IMAGING 2022. [DOI: 10.4103/jiae.jiae_38_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|
15
|
Raby J, Newton JD, Dawkins S, Lewis AJM. Cardiovascular magnetic resonance facilitates entirely contrast-free transcatheter aortic valve implantation: case report. Eur Heart J Case Rep 2021; 5:ytab378. [PMID: 34909569 PMCID: PMC8664762 DOI: 10.1093/ehjcr/ytab378] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 05/25/2021] [Accepted: 09/14/2021] [Indexed: 11/12/2022]
Abstract
Abstract
Background
Transcatheter aortic valve implantation (TAVI) is usually planned using contrast-enhanced computed tomography (CT) to determine the suitability of cardiovascular anatomy. Computed tomography for TAVI planning requires the administration of intravenous contrast, which may not be desirable in patients with severely reduced renal function.
Case summary
We present an unusual case of an 89-year-old patient with an urgent need for treatment of critical, symptomatic aortic stenosis who also had severe chronic kidney disease. We judged that this posed a relative contraindication to the use of intravenous contrast. We designed and implemented a novel, contrast-free cardiovascular magnetic resonance (CMR) protocol and used this to plan all aspects of the procedure. Transcatheter aortic valve implantation was conducted successfully with zero contrast medium administration leading to an excellent clinical result and recovery of renal function.
Conclusion
Contrast-free CMR appears to be a viable alternative to CT for planning structural aortic valve intervention in the rare cases where intravenous contrast is relatively contraindicated.
Collapse
Affiliation(s)
- Jonathan Raby
- Department of Cardiology, John Radcliffe Hospital, Headley Way, Oxford OX3 9DU, UK
| | - James D Newton
- Department of Cardiology, John Radcliffe Hospital, Headley Way, Oxford OX3 9DU, UK
| | - Sam Dawkins
- Department of Cardiology, John Radcliffe Hospital, Headley Way, Oxford OX3 9DU, UK
| | - Andrew J M Lewis
- Department of Cardiology, John Radcliffe Hospital, Headley Way, Oxford OX3 9DU, UK
- Centre for Clinical Magnetic Resonance Research, Radcliffe Department of Medicine, University of Oxford, Headley Way, Oxford OX3 9DU, UK
| |
Collapse
|
16
|
Feasibility of Aortic Annular Measurements Using Noncontrast-Enhanced Cardiac Computed Tomography in Preprocedural Evaluation of Transcatheter Aortic Valve Replacement. J Comput Assist Tomogr 2021; 46:50-55. [DOI: 10.1097/rct.0000000000001238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
17
|
Chatzaraki V, Kubik-Huch RA, Thali M, Niemann T. Quantifying image quality in chest computed tomography angiography: Evaluation of different contrast-to-noise ratio measurement methods. Acta Radiol 2021; 63:1353-1362. [PMID: 34647842 DOI: 10.1177/02841851211041813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND Contrast-to-noise ratio is used to objectively evaluate image quality in chest computed tomography angiography (CTA). Different authors define and measure contrast-to-noise ratio using different methods. PURPOSE To summarize and evaluate the different contrast-to-noise ratio calculation formulas in the current literature. MATERIAL AND METHODS A systematic review of the recent literature for studies using contrast-to-noise ratio was performed. Contrast-to-noise ratio measurement methods reported by the different authors were recorded and reproduced in three patients who underwent chest CTA in our department for exploring variations among the different measurement methods. RESULTS The search resulted in 109 articles, of which 26 were included. The studies involved 69 different measurements and overall, three different formula patterns. In all three, aorta and pulmonary arteries comprised the objects of interest in the numerator. In the denominator, standard deviation of the attenuation of the object of interest itself or of another background were used to reflect image noise. Some authors averaged the ratio values at different levels to obtain global ratio values. Using the object of interest itself for image noise calculation in the denominator compared to the usage of another background caused the most prominent variances of contrast-to-noise ratio between the two different protocols used for the reproduction of the measurements. CONCLUSION We recommend using the standard deviation of the attenuation of a background indicator as image noise rather than the object of interest itself for more reliable and comparative values. Global contrast-to-noise ratios based on averaging the values of different measurement levels should be avoided.
Collapse
Affiliation(s)
- Vasiliki Chatzaraki
- Institute of Radiology, Kantonsspital Baden, Baden, Switzerland
- Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland
| | | | - Michael Thali
- Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland
| | - Tilo Niemann
- Institute of Radiology, Kantonsspital Baden, Baden, Switzerland
| |
Collapse
|
18
|
Euler A, Taslimi T, Eberhard M, Kobe A, Reeve K, Zimmermann A, Krauss A, Gutjahr R, Schmidt B, Alkadhi H. Computed Tomography Angiography of the Aorta-Optimization of Automatic Tube Voltage Selection Settings to Reduce Radiation Dose or Contrast Medium in a Prospective Randomized Trial. Invest Radiol 2021; 56:283-291. [PMID: 33226202 DOI: 10.1097/rli.0000000000000740] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The aim of this study was to compare the image quality of low-kV protocols with optimized automatic tube voltage selection (ATVS) settings to reduce either radiation dose or contrast medium (CM) with that of a reference protocol for computed tomography angiography (CTA) of the thoracoabdominal aorta. MATERIALS AND METHODS In this institutional review board-approved, single-center, prospective randomized controlled trial, 126 patients receiving CTA of the aorta were allocated to one of three computed tomography protocols: (A) reference protocol at 120 kVp and standard weight-adapted CM dose; (B) protocol at 90 kVp, reduced radiation and standard CM dose; and (C) protocol at 90 kVp, standard radiation and reduced CM dose. All three protocols were performed on a third-generation dual-source computed tomography scanner using the semimode of the ATVS system. The image-task-dependent optimization settings of the ATVS (slider level) were adjusted to level 11 (high-contrast task) for protocols A and B and level 3 (low-contrast task) for protocol C. Radiation dose parameters were assessed. The contrast-to-noise ratios (CNRs) of protocols B and C were tested for noninferiority compared with A. Subjective image quality was assessed using a 5-point Likert scale. RESULTS Size-specific dose estimate was 34.3% lower for protocol B compared with A (P < 0.0001). Contrast medium was 20.2% lower for protocol C compared with A (P < 0.0001). Mean CNR in B and C was noninferior to protocol A (CNR of 30.2 ± 7, 33.4 ± 6.7, and 30.5 ± 8.9 for protocols A, B, and C, respectively). There was no significant difference in overall subjective image quality among protocols (4.09 ± 0.21, 4.03 ± 0.19, and 4.08 ± 0.17 for protocols A, B, and C, respectively; P = 0.4). CONCLUSIONS The slider settings of an ATVS system can be adjusted to optimize either radiation dose or CM at noninferior image quality in low-kV CTA of the aorta. This optimization could be used to extend future ATVS algorithms to take clinical risk factors like kidney function of individual patients into account.
Collapse
Affiliation(s)
- André Euler
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Tilo Taslimi
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Matthias Eberhard
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Adrian Kobe
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Kelly Reeve
- Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Zurich, Switzerland
| | - Alexander Zimmermann
- Department of Vascular Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | | | | | | | - Hatem Alkadhi
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
19
|
de Jong DJ, Veldhuis WB, Wessels FJ, de Vos B, Moeskops P, Kok M. Towards Personalised Contrast Injection: Artificial-Intelligence-Derived Body Composition and Liver Enhancement in Computed Tomography. J Pers Med 2021; 11:jpm11030159. [PMID: 33668286 PMCID: PMC7996171 DOI: 10.3390/jpm11030159] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2020] [Revised: 02/15/2021] [Accepted: 02/18/2021] [Indexed: 12/11/2022] Open
Abstract
In contrast-enhanced computed tomography, total body weight adapted contrast injection protocols have proven successful in achieving a homogeneous enhancement of vascular structures and liver parenchyma. However, because solid organs have greater perfusion than adipose tissue, the lean body weight (fat-free mass) rather than the total body weight is theorised to cause even more homogeneous enhancement. We included 102 consecutive patients who underwent a multiphase abdominal computed tomography between March 2016 and October 2019. Patients received contrast media (300 mgI/mL) according to bodyweight categories. Using regions of interest, we measured the Hounsfield unit (HU) increase in liver attenuation from unenhanced to contrast-enhanced computed tomography. Furthermore, subjective image quality was graded using a four-point Likert scale. An artificial intelligence algorithm automatically segmented and determined the body compositions and calculated the percentages of lean body weight. The hepatic enhancements were adjusted for iodine dose and iodine dose per total body weight, as well as percentage lean body weight. The associations between enhancement and total body weight, body mass index, and lean body weight were analysed using linear regression. Patients had a median age of 68 years (IQR: 58–74), a total body weight of 81 kg (IQR: 73–90), a body mass index of 26 kg/m2 (SD: ±4.2), and a lean body weight percentage of 50% (IQR: 36–55). Mean liver enhancements in the portal venous phase were 61 ± 12 HU (≤70 kg), 53 ± 10 HU (70–90 kg), and 53 ± 7 HU (≥90 kg). The majority (93%) of scans were rated as good or excellent. Regression analysis showed significant correlations between liver enhancement corrected for injected total iodine and total body weight (r = 0.53; p < 0.001) and between liver enhancement corrected for lean body weight and the percentage of lean body weight (r = 0.73; p < 0.001). Most benefits from personalising iodine injection using %LBW additive to total body weight would be achieved in patients under 90 kg. Liver enhancement is more strongly associated with the percentage of lean body weight than with the total body weight or body mass index. The observed variation in liver enhancement might be reduced by a personalised injection based on the artificial-intelligence-determined percentage of lean body weight.
Collapse
Affiliation(s)
- Daan J. de Jong
- Department of Radiology, University Medical Center Utrecht, Heilberglaan 100, 3584 CX Utrecht, The Netherlands; (D.J.d.J.); (W.B.V.); (F.J.W.)
| | - Wouter B. Veldhuis
- Department of Radiology, University Medical Center Utrecht, Heilberglaan 100, 3584 CX Utrecht, The Netherlands; (D.J.d.J.); (W.B.V.); (F.J.W.)
| | - Frank J. Wessels
- Department of Radiology, University Medical Center Utrecht, Heilberglaan 100, 3584 CX Utrecht, The Netherlands; (D.J.d.J.); (W.B.V.); (F.J.W.)
| | - Bob de Vos
- Quantib-U, Padualaan 8, 3584 CH Utrecht, The Netherlands; (B.d.V.); (P.M.)
| | - Pim Moeskops
- Quantib-U, Padualaan 8, 3584 CH Utrecht, The Netherlands; (B.d.V.); (P.M.)
| | - Madeleine Kok
- Department of Radiology, University Medical Center Utrecht, Heilberglaan 100, 3584 CX Utrecht, The Netherlands; (D.J.d.J.); (W.B.V.); (F.J.W.)
- Correspondence: ; Tel.: +31-88-75555-55
| |
Collapse
|
20
|
Choe YH, Kim SM, Park SJ. Computed tomography and magnetic resonance imaging assessment of aortic valve stenosis: an update. PRECISION AND FUTURE MEDICINE 2020. [DOI: 10.23838/pfm.2020.00093] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
|
21
|
Abd Alamir M, Nazir S, Alani A, Golub I, Gilchrist IC, Aslam F, Dhawan P, Changal K, Ostra C, Soni R, Elzanaty A, Budoff M. Multidetector computed tomography in transcatheter aortic valve replacement: an update on technological developments and clinical applications. Expert Rev Cardiovasc Ther 2020; 18:709-722. [PMID: 33063552 DOI: 10.1080/14779072.2020.1837624] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
INTRODUCTION Transcatheter aortic valve replacement (TAVR) has revolutionized the treatment of patients with underlying sever aortic valve stenosis across all spectrum of the disease. CT imaging is so crucial to the pre procedural planning, to incorporate the information from the CT imaging in the decision making intraprocedurally and to predict and identity the post procedural complications.Areas covered: In this article, we review available studies on CT role in TAVR procedure and provide update on the technological developments and clinical applications.Expert opinion: CT imaging, with its high resolution, and in particular its utilization in aortic annular measurements, bicuspid aortic valve assessment, hypoattenuated leaflet thickening and valve in valve therapy proved to be the ideal approach to study the mechanisms of aortic stenosis, detection of high-risk anatomy, more accurate risk stratification and thus to allow a personalized catheter based intervention of the affected patients.
Collapse
Affiliation(s)
- Moshrik Abd Alamir
- Department of Cardiology, Stony Brook University Hospital, Health Sciences Tower , Stony Brook, NY, USA
| | - Salik Nazir
- Department of Cardiology, University of Toledo , Toledo, OH, USA
| | - Anas Alani
- Loma Linda University , Loma Linda, CA, USA
| | - Ilana Golub
- Department of Cardiology, Lundquist Institute , Torrance, CA, USA
| | - Ian C Gilchrist
- Department of Cardiology, Stony Brook University Hospital, Health Sciences Tower , Stony Brook, NY, USA
| | - Faisal Aslam
- Department of Cardiology, Stony Brook University Hospital, Health Sciences Tower , Stony Brook, NY, USA
| | - Puneet Dhawan
- David Geffen School of Medicine at UCLA, Department of Surgery, Los Angeles County Harbor-UCLA Medical Center , Torrance, CA, USA
| | - Khalid Changal
- Department of Cardiology, University of Toledo , Toledo, OH, USA
| | - Carson Ostra
- Department of Cardiology, University of Toledo , Toledo, OH, USA
| | - Ronak Soni
- Department of Cardiology, University of Toledo , Toledo, OH, USA
| | - Ahmad Elzanaty
- Department of Cardiology, University of Toledo , Toledo, OH, USA
| | - Matthew Budoff
- Department of Cardiology, Lundquist Institute , Torrance, CA, USA
| |
Collapse
|
22
|
Gallo GS, Gerasia R, Caruso C, Tafaro C, Iannazzo E, Cannataci C, Gentile G, Mamone G, Gandolfo C, Miraglia R. Feasibility of combined ECG-Gated and Helical acquisition mode in a pre-TAVI computed tomography angiography protocol using a fixed low-volume contrast medium injection. Eur J Radiol 2020; 131:109239. [PMID: 32911128 DOI: 10.1016/j.ejrad.2020.109239] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 08/10/2020] [Accepted: 08/17/2020] [Indexed: 10/23/2022]
Abstract
BACKGROUND To investigate the feasibility, image quality, and clinical implications of a combined ECG-gated and helical acquisition mode in a computed tomography angiography (CTA) protocol in patients scheduled for transcatheter aortic valve implantation (TAVI) using a fixed, low-volume, contrast medium injection. METHODS Between July and October 2019, 43 TAVI candidates underwent investigation with CTA using a 64-slice CT scanner. Images obtained were prospectively evaluated. 65 mL of low iodine dose contrast medium (CM), followed by 25 mL of saline, were administered using a fixed multiphasic injection protocol in all patients. Patients were divided into three groups based on BMI: Group 1 (n = 9) with BMI < 22 kg/m2; Group 2 (n = 22) with BMI 22-29 kg/m2; Group 3 (n = 12) with BMI > 29 kg/m2. Images were evaluated for image quality, vessel attenuation (HU), Signal-to-Noise Ratio (SNR), Contrast-to-Noise Ratio (CNR) and estimated radiation dose. Image quality of the aortic root and iliac-femoral vessels was diagnostic in all patients. RESULTS Vascular attenuation was > 200 HU and CNR > 3 at all vessel levels. CONCLUSION Data from our study suggest that it is possible to image the aortic annulus and aorto-iliac anatomy and obtain high image quality in all patients by using a combined ECG-gated and helical acquisition mode in a computed tomography angiography (CTA) protocol with a fixed low-volume contrast medium injection (65 mL). This allows for accurate CT measurements of the aortic annulus, recruitment of patients for TAVI and facilitates pre-procedural planning in these high surgical risk patients.
Collapse
Affiliation(s)
- Giuseppe S Gallo
- Radiology Unit, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Via Ernesto Tricomi 5, 90127 Palermo, Italy.
| | - Roberta Gerasia
- Radiology Unit, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Via Ernesto Tricomi 5, 90127 Palermo, Italy.
| | - Calogero Caruso
- Radiology Unit, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Via Ernesto Tricomi 5, 90127 Palermo, Italy.
| | - Corrado Tafaro
- Radiology Unit, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Via Ernesto Tricomi 5, 90127 Palermo, Italy.
| | - Erica Iannazzo
- Radiology Unit, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Via Ernesto Tricomi 5, 90127 Palermo, Italy.
| | - Christine Cannataci
- Medical Imaging Department, Mater Dei Hospital, Triq Dun Karm, MSD9032 L-Imsida, Malta.
| | - Giovanni Gentile
- Radiology Unit, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Via Ernesto Tricomi 5, 90127 Palermo, Italy.
| | - Giuseppe Mamone
- Radiology Unit, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Via Ernesto Tricomi 5, 90127 Palermo, Italy.
| | - Caterina Gandolfo
- Interventional Cardiology Unit, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Via Ernesto Tricomi 5, 90127 Palermo, Italy.
| | - Roberto Miraglia
- Radiology Unit, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Via Ernesto Tricomi 5, 90127 Palermo, Italy.
| |
Collapse
|
23
|
Maffeo D, Bettari L, Latib A, Maiandi C, Villa E, Messina A, Saccocci M, Arneri A, Cuccia C, Troise G. Transfemoral transcatheter aortic valve replacement without contrast medium using the Medtronic CoreValve system: a single center experience. THE JOURNAL OF CARDIOVASCULAR SURGERY 2020; 61:489-495. [DOI: 10.23736/s0021-9509.20.11083-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
24
|
Horehledova B, Mihl C, Boswijk E, Crombag GAJC, Nijssen EC, Nelemans PJ, Veenstra LF, Wildberger JE, Das M. Retrospectively ECG-gated helical vs. non-ECG-synchronized high-pitch CTA of the aortic root for TAVI planning. PLoS One 2020; 15:e0232673. [PMID: 32396570 PMCID: PMC7217477 DOI: 10.1371/journal.pone.0232673] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2019] [Accepted: 04/19/2020] [Indexed: 11/24/2022] Open
Abstract
Background Multidetector computed tomography (MDCT) plays a key role in patient assessment prior to transcatheter aortic valve implantation (TAVI). However, to date no consensus has been established on what is the optimal pre-procedural imaging protocol. Variability in pre-TAVI acquisition protocols may lead to discrepancies in aortic annulus measurements and may potentially influence prosthesis size selection. Purpose The current study evaluates the magnitude of differences in aortic annulus measurements using max-systolic, end-diastolic, and non-ECG-synchronized imaging, as well as the impact of method on prosthesis size selection. Material and methods Fifty consecutive TAVI-candidates, who underwent retrospectively-ECG-gated CT angiography (CTA) of the aortic root, directly followed by non-ECG-synchronized high-pitch CT of the entire aorta, were retrospectively included. Aortic root dimensions were assessed at each 10% increment of the R-R interval (0–100%) and on the non-ECG-synchronized scan. Dimensional changes within the cardiac cycle were evaluated using a 1-way repeated ANOVA. Agreement in measurements between max-systole, end-diastole and non-ECG-synchronized scans was assessed with Bland-Altman analysis. Results Maximal dimensions of the aortic root structures and minimum annulus-coronary ostia distances were measured during systole. Max-systolic measurements were significantly and substantially larger than end-diastolic (p<0.001) and non-ECG-synchronized measurements (p<0.001). Due to these discrepancies, the three methods resulted in the same prosthesis size selection in only 48–62% of patients. Conclusions The systematic differences between max-systolic, end-diastolic and non-ECG-synchronized measurements for relevant aortic annular dimensions are both statistically significant and clinically relevant. Imaging strategy impacts prosthesis size selection in nearly half the TAVI-candidates. End-diastolic and non-ECG-synchronized imaging does not provide optimal information for prosthesis size selection. Systolic image acquisition is necessary for assessment of maximal annular dimensions and minimum annulus-coronary ostia distances.
Collapse
Affiliation(s)
- Barbora Horehledova
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands
- * E-mail:
| | - Casper Mihl
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Ellen Boswijk
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Genevieve A. J. C. Crombag
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Estelle C. Nijssen
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Patty J. Nelemans
- Department of Epidemiology, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Leo F. Veenstra
- Department of Cardiology, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Joachim E. Wildberger
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Marco Das
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands
| |
Collapse
|
25
|
Shnayien S, Bressem KK, Beetz NL, Asbach P, Hamm B, Niehues SM. Radiation Dose Reduction in Preprocedural CT Imaging for TAVI/TAVR Using a Novel 3-Phase Protocol: A Single Institution's Experience. ROFO-FORTSCHR RONTG 2020; 192:1174-1182. [PMID: 32299112 DOI: 10.1055/a-1150-7646] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
PURPOSE To retrospectively investigate the effectiveness of a novel 3-phase protocol for computed tomography (CT) before transcatheter aortic valve implantation/transcatheter aortic valve replacement (TAVI/TAVR) in terms of radiation dose and image quality. MATERIALS AND METHODS A total of 107 nonrandomized patients (81 ± 7.4 years) scheduled for TAVI/TAVR underwent preprocedural CT on an 80-row CT scanner. 55 patients underwent a combined ECG-synchronized spiral scan of the chest and non-ECG-synchronized spiral scan of the abdomen/pelvis as recommended by the Society of Cardiovascular Computed Tomography (SCCT). 52 patients underwent an updated 3-phase variable helical pitch (vHP3) protocol combining a non-ECG-synchronized spiral scan of the upper thoracic aperture, followed by a prospective ECG-synchronized spiral scan of the heart, and a non-ECG-synchronized abdominal/pelvic spiral scan. The radiation dose was determined from an automatically generated protocol based on the CT dose index (CTDI). Objective image quality in terms of vessel attenuation and image noise was measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Subjective image quality was evaluated using a 4-point scale and compared for interrater agreement using Cohen's weighted kappa coefficient (κw). All data were compared and statistically analyzed. RESULTS Use of the novel 3-phase vHP3 protocol reduced the dose-length product (DLP) from 1256.58 ± 619.05 mGy*cm to 790.90 ± 238.15 mGy*cm, reducing the effective dose (E) from 21.36 ± 10.52 mSv to 13.44 ± 4.05 mSv and size-specific dose estimates (SSDE) from 20.85 ± 7.29 mGy to 13.84 ± 2.94 mGy (p < 0.001). There were no significant differences in objective and subjective image quality between the two protocols and between the two readers. CONCLUSION The novel 3-phase vHP3 protocol significantly reduces the radiation dose of preprocedural TAVI/TAVR CT without a loss of image quality. KEY POINTS · The use of a novel 3-phase protocol for preprocedural TAVI/TAVR CT reduces radiation dose by 37 % compared to a combined ECG-synchronized and non-ECG-synchronized spiral CT protocol.. · Objective image quality remains unaffected as image noise, SNR, and CNR did not differ significantly between the two protocols. The average attenuation of the aortic root and abdominal aorta exceeded 450 HU in both protocols.. · The average subjective image quality ratings were good to excellent for both protocols with almost perfect to substantial interrater agreement.. CITATION FORMAT · Shnayien S, Bressem KK, Beetz NL et al. Radiation Dose Reduction in Preprocedural CT Imaging for TAVI/TAVR Using a Novel 3-Phase Protocol: A Single Institution's Experience. Fortschr Röntgenstr 2020; 192: 1174 - 1182.
Collapse
Affiliation(s)
- Seyd Shnayien
- Radiology, Charité-Universitätsmedizin Berlin, Germany
| | | | | | | | - Bernd Hamm
- Radiology, Charité-Universitätsmedizin Berlin, Germany
| | | |
Collapse
|
26
|
Suchá D, Kino A, Bogart K, Molvin L, Cheng X, Fearon W, Fischbein M, Fleischmann D. Effect of low contrast medium-dose CTA on device sizing and access vessel assessment for TAVR. Eur J Radiol 2020; 124:108826. [DOI: 10.1016/j.ejrad.2020.108826] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Revised: 12/09/2019] [Accepted: 01/06/2020] [Indexed: 01/22/2023]
|
27
|
Onoda H, Ueno H, Hashimoto M, Kuwahara H, Sobajima M, Kinugawa K. Clinical Advantages of Using Low Tube Voltage in Third-Generation 192-Slice Dual-Source Computed Tomographic Angiography Before Transcatheter Aortic Valve Implantation. Int Heart J 2019; 60:1091-1097. [PMID: 31484865 DOI: 10.1536/ihj.18-693] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Low-voltage computed tomographic angiography (CTA) is a highly effective technique to reduce contrast media volume. We sought to examine the suitability of low tube voltage CTA with a reduced contrast media volume protocol using third-generation 192-slice dual-source CT in patients undergoing transcatheter aortic valve implantation (TAVI). CTA was performed to aid TAVI planning for 40 consecutive patients with severe aortic stenosis. For the first 10 patients (120/100 kV group), we used a conventional tube voltage combined CTA protocol (an ECG-gated helical scan; 120 kV, non-gated helical scan; 100 kV). For the subsequent 30 patients (70-kV group), we adopted a low tube voltage CTA protocol. We evaluated vascular attenuation, image noise, contrast-to-noise ratio (CNR), and renal function. The mean contrast media (CM) volume was 77.7 ± 17.7 mL in the 120/100-kV group and 30.9 ± 6.3 mL in the 70-kV group (P < 0.001). In the images of the aortic valve complex, the mean attenuation was not significant difference for both groups. In the images of the aorto-femoral arteries, mean attenuation was > 250 Hounsfield Units and CNR was > 10 in all vascular segments for both groups. There was no significant difference in the change of renal function in the 70-kV group, but renal function in the 120/100-kV group decreased within 1-3 months after CTA. Low tube voltage CTA using third-generation dual-source CT is suitable to assess procedural planning for TAVI. This approach maintains image quality and reduces the required CM volume.
Collapse
Affiliation(s)
- Hiroshi Onoda
- Second Department of Internal Medicine, University of Toyama
| | - Hiroshi Ueno
- Second Department of Internal Medicine, University of Toyama
| | | | | | - Mitsuo Sobajima
- Second Department of Internal Medicine, University of Toyama
| | | |
Collapse
|
28
|
Francone M, Budde RPJ, Bremerich J, Dacher JN, Loewe C, Wolf F, Natale L, Pontone G, Redheuil A, Vliegenthart R, Nikolaou K, Gutberlet M, Salgado R. CT and MR imaging prior to transcatheter aortic valve implantation: standardisation of scanning protocols, measurements and reporting-a consensus document by the European Society of Cardiovascular Radiology (ESCR). Eur Radiol 2019; 30:2627-2650. [PMID: 31489471 PMCID: PMC7160220 DOI: 10.1007/s00330-019-06357-8] [Citation(s) in RCA: 146] [Impact Index Per Article: 24.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Revised: 05/29/2019] [Accepted: 07/03/2019] [Indexed: 01/04/2023]
Abstract
Abstract Transcatheter aortic valve replacement (TAVR) is a minimally invasive alternative to conventional aortic valve replacement in symptomatic patients with severe aortic stenosis and contraindications to surgery. The procedure has shown to improve patient’s quality of life and prolong short- and mid-term survival in high-risk individuals, becoming a widely accepted therapeutic option which has been integrated into current clinical guidelines for the management of valvular heart disease. Nevertheless, not every patient at high-risk for surgery is a good candidate for TAVR. Besides clinical selection, which is usually established by the Heart Team, certain technical and anatomic criteria must be met as, unlike in surgical valve replacement, annular sizing is not performed under direct surgical evaluation but on the basis of non-invasive imaging findings. Present consensus document was outlined by a working group of researchers from the European Society of Cardiovascular Radiology (ESCR) and aims to provide guidance on the utilisation of CT and MR imaging prior to TAVR. Particular relevance is given to the technical requirements and standardisation of the scanning protocols which have to be tailored to the remarkable variability of the scanners currently utilised in clinical practice; recommendations regarding all required pre-procedural measurements and medical reporting standardisation have been also outlined, in order to ensure quality and consistency of reported data and terminology. Key Points • To provide a reference document for CT and MR acquisition techniques, taking into account the significant technological variation of available scanners. • To review all relevant measurements that are required and define a step-by-step guided approach for the measurements of different structures implicated in the procedure. • To propose a CT/MR reporting template to assist in consistent communication between various sites and specialists involved in the procedural planning. Electronic supplementary material The online version of this article (10.1007/s00330-019-06357-8) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Marco Francone
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University, Policlinico Umberto I, V.le Regina Elena 324, 00161, Rome, Italy.
| | - Ricardo P J Budde
- Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Jens Bremerich
- Department of Radiology, University of Basel Hospital, Basel, Switzerland
| | - Jean Nicolas Dacher
- Department of Radiology, Normandie University, UNIROUEN, INSERM U1096 - Rouen University Hospital, F 76000, Rouen, France
| | - Christian Loewe
- Division of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Florian Wolf
- Division of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Luigi Natale
- Department of Radiological Sciences - Institute of Radiology, Catholic University of Rome, "A. Gemelli" University Hospital, Rome, Italy
| | | | - Alban Redheuil
- Institute of Cardiometabolism and Nutrition (ICAN), Paris, France
- Department of Cardiovascular and Thoracic, Imaging and Interventional Radiology, Institute of Cardiology, APHP, Pitié-Salpêtrière University Hospital, Paris, France
- Laboratoire d'Imagerie Biomédicale, Sorbonne Universités, UPMC Univ Paris 06, INSERM 1146, CNRS 7371, Paris, France
| | - Rozemarijn Vliegenthart
- Department of Radiology, University of Groningen, University Medical Center Groningen, Groningen, Netherlands
| | - Kostantin Nikolaou
- Department of Diagnostic and Interventional Radiology, University of Tuebingen, Tübingen, Germany
| | - Matthias Gutberlet
- Diagnostic and Interventional Radiology, University of Leipzig-Heart Center, Leipzig, Germany
| | - Rodrigo Salgado
- Department of Radiology, Antwerp University Hospital, Antwerp, Belgium
- Department of Radiology, Holy Heart Hospital, Lier, Belgium
| |
Collapse
|
29
|
Hachulla AL, Noble S, Ronot M, Guglielmi G, de Perrot T, Montet X, Vallée JP. Low Iodine Contrast Injection for CT Acquisition Prior to Transcatheter Aortic Valve Replacement: Aorta Assessment and Screening for Coronary Artery Disease. Acad Radiol 2019; 26:e150-e160. [PMID: 30076081 DOI: 10.1016/j.acra.2018.06.016] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2018] [Revised: 06/17/2018] [Accepted: 06/18/2018] [Indexed: 10/28/2022]
Abstract
RATIONALE AND OBJECTIVES To assess both the complete aorta and coronary artery disease (CAD) using low iodine contrast computed-tomography angiography before transcatheter aortic valve replacement. MATERIALS AND METHODS 84 patients underwent computed-tomography angiography before transcatheter aortic valve replacement: 42 with standard iodine injection protocol (P1:120 mL); 42 with a low dose iodine injection protocol (P2:60 mL). Mean attenuation and subjective image quality were rated at different levels of the aorta, iliac and coronary arteries. Sensitivity, specificity, negative and positive predictive values for depiction of CAD were calculated according to the coronary angiography. RESULTS Mean attenuation was significantly higher in P1 for the ascending aorta (p < 0.001). No significant difference was observed regarding image quality of the aortic valve (p = 0.876), the ascending aorta (p = 0.306), or the abdominal aorta (p = 1.0). Diagnostic image quality of coronary arteries was excellent for P1 and P2 (94.6% vs 96.5%, p = 0.08). Sensitivity, specificity, negative and positive predictive values, and accuracy for depiction of CAD were excellent for P1 and P2 (100% vs 100%; 79% vs 86%, 70% vs 87%, 100% vs 100% and 86% vs 93%) without significant differences (p = 0.93; p = 0.58; p = 0.90; p = 1.0; p = 0.74), respectively. CONCLUSION Despite a difference in aortic mean attenuation, a reduced iodine injection protocol showed similar image quality and detection of CAD in comparison with a standard injection protocol.
Collapse
|
30
|
Abstract
Due to its high temporal and isotropic spatial resolution, CT has become firmly established for pre-procedural imaging in the context of structural heart disease interventions. CT allows to very exactly measure dimensions of the target structure, CT can provide information regarding the access route and, as a very valuable addition, volumetric CT data sets can be used to identify fluoroscopic projection angulations to optimally visualize the target structure and place devices. This review provides an overview of current methods and applications of pre-interventional CT to support adult cardiac interventions including transcatheter aortic valve implantation, percutaneous mitral valve intervention, left atrial appendage occlusion and paravalvular leak closure.
Collapse
Affiliation(s)
- Michaela M Hell
- Department of Cardiology, Faculty of Medicine, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU) , Erlangen , Germany
| | - Stephan Achenbach
- Department of Cardiology, Faculty of Medicine, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU) , Erlangen , Germany
| |
Collapse
|
31
|
Chiocchi M, Forcina M, Morosetti D, Pugliese L, Cavallo AU, Citraro D, De Stasio V, Presicce M, Floris R, Romeo F. The role of computed tomography in the planning of transcatheter aortic valve implantation: a retrospective analysis in 200 procedures. J Cardiovasc Med (Hagerstown) 2019; 19:571-578. [PMID: 30015782 DOI: 10.2459/jcm.0000000000000695] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
AIM The aim of our study is to show the importance of multislice computed tomography (CT) assessment in the overall management and diagnostic framework of transcatheter aortic valve replacement (TAVI) procedure candidates. METHODS Between June 2015 and April 2017, 200 patients with severe aortic stenosis, not eligible for surgery, were enrolled, as defined by EuroSCORE; they were submitted to TAVI at the interventional cardiology department of the Tor Vergata Polyclinic. CT studies were performed using a 64-slice scanner. RESULTS The reports and datasets produced during the pre-TAVI CT evaluation were retrospectively evaluated. DISCUSSION In TAVI candidates, accurate aortic valve shape and dimensions evaluation is crucial for the proper deployment of the prosthetic valve and in order to reduce postprocedural complications. ECG retrospective gated cardiac CT gives the clinician three-dimensional images of the heart, with high spatial resolution and multiplanar reconstructions allowing accurate visualization of the aortic annulus and coronary ostia to be obtained, and the evaluation of arterial calcifications. Furthermore, CT can provide data on the suitability of peripheral vascular accesses. Moreover, this technique can point out the presence of clinically relevant extracardiac findings. Therefore, CT evaluation assures a safe, reliable and prognostically relevant method for TAVI preprocedural planning. CONCLUSION Our study remarks the importance of CT assessment in the overall management and diagnostic framework of TAVI candidates; the information provided is essential in order to minimize possible complications and to improve the quality of the therapeutic planning.
Collapse
Affiliation(s)
- Marcello Chiocchi
- Fondazione PTV Policlinico Tor Vergata, Dipartimento di Diagnostica per Immagini, Imaging Molecolare, Radiologia Interventistica e Radioterapia, Rome, Italy
| | | | | | | | | | | | | | | | | | | |
Collapse
|
32
|
|
33
|
Higuchi R, Tobaru T, Hagiya K, Saji M, Takamisawa I, Shimizu J, Iguchi N, Takanashi S, Takayama M. Renoprotective Transcatheter Aortic Valve Implantation Without Contrast Media. Int Heart J 2018; 59:1469-1472. [PMID: 30249922 DOI: 10.1536/ihj.17-588] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The therapeutic role of transcatheter aortic valve implantation (TAVI) in high surgical risk or inoperable cases has been established. Most of the candidates for TAVI are elderly and have multiple comorbidities including chronic kidney disease. However, contrast-enhanced computed tomography and coronary angiography, both of which require iodine contrast media, are essential for pre-procedural planning. In addition, TAVI could have adverse effects on kidney function including contrast media-induced nephrotoxicity. Acute kidney injury following TAVI has been reported to be related to poor prognosis. In a case with advanced renal dysfunction, we successfully avoided post-procedural acute kidney injury by performing pre-procedural evaluation using minimal contrast and TAVI without contrast media. If anatomical conditions and experiences of the heart team are adequate, renoprotective TAVI should be a favorable therapy for patients with aortic stenosis complicated by renal dysfunction.
Collapse
Affiliation(s)
| | | | | | - Mike Saji
- Department of Cardiology, Sakakibara Heart Institute
| | | | - Jun Shimizu
- Department of Anesthesiology, Sakakibara Heart Institute
| | - Nobuo Iguchi
- Department of Cardiology, Sakakibara Heart Institute
| | | | | |
Collapse
|
34
|
Annoni AD, Andreini D, Pontone G, Mancini ME, Formenti A, Mushtaq S, Baggiano A, Conte E, Guglielmo M, Muscogiuri G, Muratori M, Fusini L, Trabattoni D, Teruzzi G, Coutinho Santos AI, Agrifoglio M, Pepi M. CT angiography prior to TAVI procedure using third-generation scanner with wide volume coverage: feasibility, renal safety and diagnostic accuracy for coronary tree. Br J Radiol 2018; 91:20180196. [PMID: 30004788 DOI: 10.1259/bjr.20180196] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Abstract
OBJECTIVE: To evaluate feasibility, image quality and accuracy of a reduced contrast volume protocol for pre-procedural CT imaging in transcatheter aortic valve implantation (TAVI) using a third generation wide array CT scanner. METHODS: 115 consecutive patients (51F, mean age 82.5 ± 6.2 y, mean BMI 26.7 ± 3.6) referred for TAVI were examined with wide-array CT scanner with a combined scan protocol and a total amount of 50 ml contrast agent. A 4-point visual scale (4-1) was used to assess image quality . Contrast attenuation values (HU) and contrast-to-noise ratio (CNR) were measured at the level of the aortic root, ascending/descending aorta, subrenal aorta and at the level of right and left common femoral arteries. Coronary tree was assessed and compared with invasive coronary angiography (ICA). Aortic annulus measurements were compared with final procedural results. Patients creatinine was monitored at the baseline and 72 h after procedure. RESULTS: Median quality score value was >3. Mean CNR at the level of the aortic root, ascending/descending aorta, subrenal aorta and at the level of right and left common femoral arteries were 14.8 ± 2.3, 15.7 ± 1.7, 14.9 ± 3.1, 15.8 ± 4.7, 20.3 ± 9.9, 20.8 ± 6.9 respectively. Only 1 patient had moderate paravalvular regurgitation. In comparison with ICA for coronary assessment CTA showed in a segment based analysis sensitivity, specificity, negative predictive value, positive predictive value and accuracy of 97, 85, 99,62 and 88% respectively. Mean creatinine before CT and 72 h after procedure were 1.21 ± 0.52 and1.22 ± 0.49 mg dl-1. Mean DLP was 442.4 ± 21.2 mGy/cm. CONCLUSION: CT with low contrast volume is feasible and clinically useful, allowing precise pre-procedural TAVI planning with accurate assessment of coronary tree. ADVANCES IN KNOWLEDGE: third generation CT scanner with whole heart coverage allows examinations for assessment of aorta and coronary arteries in TAVI planning using low dose of contrast medium maintaining good quality and high diagnostic accuracy.
Collapse
Affiliation(s)
- Andrea D Annoni
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Daniele Andreini
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Gianluca Pontone
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | | | - Alberto Formenti
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Saima Mushtaq
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | | | - Edoardo Conte
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Marco Guglielmo
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Giuseppe Muscogiuri
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Manuela Muratori
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Laura Fusini
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Daniela Trabattoni
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Giovanni Teruzzi
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Ana I Coutinho Santos
- 2 Imaging Department, Centro Hospitalar de Lisboa Ocidental, E.P.E , Lisboa , Portugal
| | - Marco Agrifoglio
- 3 Department of Clinical Sciences and Community Health, University of Milan , Milan , Italy.,4 Cardiac Surgery Department, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Mauro Pepi
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| |
Collapse
|
35
|
Foley TR, Stinis CT. Imaging Evaluation and Interpretation for Vascular Access for Transcatheter Aortic Valve Replacement. Interv Cardiol Clin 2018; 7:285-291. [PMID: 29983141 DOI: 10.1016/j.iccl.2018.03.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Transcatheter aortic valve replacement (TAVR) has emerged as an effective therapy for aortic stenosis in patients who are at intermediate and high surgical risk. Vascular access remains critical to the success of the TAVR procedure. This article reviews the use of imaging in planning and executing TAVR access.
Collapse
Affiliation(s)
- T Raymond Foley
- Division of Interventional Cardiology, Scripps Clinic, 9898 Genessee Avenue, La Jolla, CA 92037, USA
| | - Curtiss T Stinis
- Division of Interventional Cardiology, Scripps Clinic, 9898 Genessee Avenue, La Jolla, CA 92037, USA.
| |
Collapse
|
36
|
Chaikriangkrai K, Jhun HY, Shantha GPS, Abdulhak AB, Tandon R, Alqasrawi M, Klappa A, Pancholy S, Deshmukh A, Bhama J, Sigurdsson G. Diagnostic Accuracy of Coronary Computed Tomography Before Aortic Valve Replacement: Systematic Review and Meta-Analysis. J Thorac Imaging 2018; 33:207-216. [PMID: 29389809 DOI: 10.1097/rti.0000000000000322] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
PURPOSE In aortic stenosis patients referred for surgical and transcatheter aortic valve replacement (AVR), the evidence of diagnostic accuracy of coronary computed tomography angiography (CCTA) has been limited. The objective of this study was to investigate the diagnostic accuracy of CCTA for significant coronary artery disease (CAD) in patients referred for AVR using invasive coronary angiography (ICA) as the gold standard. MATERIALS AND METHODS We searched databases for all diagnostic studies of CCTA in patients referred for AVR, which reported diagnostic testing characteristics on patient-based analysis required to pool summary sensitivity, specificity, positive-likelihood ratio, and negative-likelihood ratio. Significant CAD in both CCTA and ICA was defined by >50% stenosis in any coronary artery, coronary stent, or bypass graft. RESULTS Thirteen studies evaluated 1498 patients (mean age, 74 y; 47% men; 76% transcatheter AVR). The pooled prevalence of significant stenosis determined by ICA was 43%. Hierarchical summary receiver-operating characteristic analysis demonstrated a summary area under curve of 0.96. The pooled sensitivity, specificity, and positive-likelihood and negative-likelihood ratios of CCTA in identifying significant stenosis determined by ICA were 95%, 79%, 4.48, and 0.06, respectively. In subgroup analysis, the diagnostic profiles of CCTA were comparable between surgical and transcatheter AVR. CONCLUSIONS Despite the higher prevalence of significant CAD in patients with aortic stenosis than with other valvular heart diseases, our meta-analysis has shown that CCTA has a suitable diagnostic accuracy profile as a gatekeeper test for ICA. Our study illustrates a need for further study of the potential role of CCTA in preoperative planning for AVR.
Collapse
Affiliation(s)
| | - Hye Yeon Jhun
- Department of Medicine, University of Kansas Medical Center, Kansas City, KS
| | | | - Aref Bin Abdulhak
- Heart and Vascular Center, University of Iowa Hospitals and Clinics, Iowa City, IA
| | - Rudhir Tandon
- Heart and Vascular Center, University of Iowa Hospitals and Clinics, Iowa City, IA
| | - Musab Alqasrawi
- Heart and Vascular Center, University of Iowa Hospitals and Clinics, Iowa City, IA
| | - Anthony Klappa
- Heart and Vascular Center, University of Iowa Hospitals and Clinics, Iowa City, IA
| | - Samir Pancholy
- The Wright Center for Graduate Medical Education, Scranton, PA
| | | | - Jay Bhama
- Heart and Vascular Center, University of Iowa Hospitals and Clinics, Iowa City, IA
| | - Gardar Sigurdsson
- Heart and Vascular Center, University of Iowa Hospitals and Clinics, Iowa City, IA
| |
Collapse
|
37
|
Horehledova B, Mihl C, Schwemmer C, Hendriks BMF, Eijsvoogel NG, Kietselaer BLJH, Wildberger JE, Das M. Aortic root evaluation prior to transcatheter aortic valve implantation-Correlation of manual and semi-automatic measurements. PLoS One 2018; 13:e0199732. [PMID: 29953507 PMCID: PMC6023104 DOI: 10.1371/journal.pone.0199732] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Accepted: 06/13/2018] [Indexed: 12/21/2022] Open
Abstract
Background Pre-procedural TAVI planning requires highly sophisticated and time-consuming manual measurements performed by experienced readers. Semi-automatic software may assist with partial automation of assessment of multiple parameters. The aim of this study was to evaluate differences between manual and semi-automatic measurements in terms of agreement and time. Methods One hundred and twenty TAVI candidates referred for the retrospectively ECG-gated CTA (2nd and 3rd generation dual source CT) were evaluated. Fully manual and semi-automatic measurements of fourteen aortic root parameters were assessed in the 20% phase of the R-R interval. Reading time was compared using paired samples t-test. Inter-software agreement was calculated using the Intraclass correlation coefficient (ICC) in a 2-way mixed effects model. Differences between manual and semi-automatic measurements were evaluated using Bland-Altman analysis. Results The time needed for evaluation using semi-automatic assessment (3 min 24 s ± 1 min 7 s) was significantly lower (p<0.001) compared to a fully manual approach (6 min 31 sec ± 1 min 1 sec). Excellent inter-software agreement was found (ICC = 0.93 ± 0.0; range:0.90–0.95). The same prosthesis size from manual and semi-automatic measurements was selected in 92% of cases, when sizing was based on annular area. Prosthesis sizing based on annular short diameter and perimeter agreed in 99% and 96% cases, respectively. Conclusion Use of semi-automatic software in pre-TAVI evaluation results in comparable results in respect of measurements and selected valve prosthesis size, while necessary reading time is significantly lower.
Collapse
Affiliation(s)
- Barbora Horehledova
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands
- * E-mail:
| | - Casper Mihl
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Chris Schwemmer
- Computed Tomography Research & Development, Siemens Healthcare GmbH, Forchheim, Germany
| | - Babs M. F. Hendriks
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Nienke G. Eijsvoogel
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Bastiaan L. J. H. Kietselaer
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands
- Department of Cardiology, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Joachim E. Wildberger
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Marco Das
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands
| |
Collapse
|
38
|
Horehledova B, Mihl C, Milanese G, Brans R, Eijsvoogel NG, Hendriks BMF, Wildberger JE, Das M. CT Angiography in the Lower Extremity Peripheral Artery Disease Feasibility of an Ultra-Low Volume Contrast Media Protocol. Cardiovasc Intervent Radiol 2018; 41:1751-1764. [PMID: 29789875 PMCID: PMC6182764 DOI: 10.1007/s00270-018-1979-z] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2018] [Accepted: 04/30/2018] [Indexed: 12/17/2022]
Abstract
Purpose The ALARA principle is not only relevant for effective dose (ED) reduction, but also applicable for contrast media (CM) management. Therefore, the aim was to evaluate the feasibility of an ultra-low CM protocol in the assessment of peripheral artery disease (PAD).
Materials and methods Fifty PAD patients were scanned on third-generation dual-source computed tomography, from diaphragm to the forefoot, as follows: tube voltage: 70 kV, reference effective tube current: 90 mAs, collimation: 192 × 2 × 0.6 mm, with individualized acquisition timing. The protocol ED (mSv) was quantified with dedicated software. CM protocol consisted of 15 ml test bolus and 30 ml main bolus (300 mgI/ml) injected at 5 ml/s, followed by a 40 ml saline chaser at the same flow rate. Aorto-popliteal bolus transit time was used to calculate the overall acquisition time and delay. Objective (hounsfield units—HU; contrast-to-noise ratio—CNR) and subjective image quality (four-point Likert score) were assessed at different anatomical regions from the aorta down to the forefoot. Results Mean attenuation values were exceeding 250 HU from aorta down to the anterior tibial artery with CNR < 13. However, decline in attenuation was observed in more distal region with mean values of 165 and 199 HU, in left and right dorsalis pedis artery, respectively. Mode subjective image quality from the level of aorta down to the popliteal segment was excellent; below the knee mode score was good. The mean ED per protocol was 1.1 ± 0.5 mSv. Conclusion Use of an ultra-low CM volume protocol at 70 kV is feasible in the evaluation of PAD, resulting in good to excellent image quality with mean ED of 1.1 ± 0.5 mSv. Level of evidence Level 3, Local non-random sample
Collapse
Affiliation(s)
- Barbora Horehledova
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, P. Debyelaan 25, PO Box 5800, 6202 AZ, Maastricht, The Netherlands.
- CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands.
| | - Casper Mihl
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, P. Debyelaan 25, PO Box 5800, 6202 AZ, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands
| | - Gianluca Milanese
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, P. Debyelaan 25, PO Box 5800, 6202 AZ, Maastricht, The Netherlands
- Division of Radiology, Department of Medicine and Surgery, University of Parma, Parma, Italy
| | - Rutger Brans
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, P. Debyelaan 25, PO Box 5800, 6202 AZ, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands
| | - Nienke G Eijsvoogel
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, P. Debyelaan 25, PO Box 5800, 6202 AZ, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands
| | - Babs M F Hendriks
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, P. Debyelaan 25, PO Box 5800, 6202 AZ, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands
| | - Joachim E Wildberger
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, P. Debyelaan 25, PO Box 5800, 6202 AZ, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands
| | - Marco Das
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, P. Debyelaan 25, PO Box 5800, 6202 AZ, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands
- Department of Diagnostic and Interventional Radiology, Helios Kliniken Duisburg GmbH, Duisburg, Germany
| |
Collapse
|
39
|
Impact of Contrast Media Concentration on Low-Kilovolt Computed Tomography Angiography. Invest Radiol 2018; 53:264-270. [DOI: 10.1097/rli.0000000000000437] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
40
|
Nagayama Y, Tanoue S, Tsuji A, Urata J, Furusawa M, Oda S, Nakaura T, Utsunomiya D, Yoshida E, Yoshida M, Kidoh M, Tateishi M, Yamashita Y. Application of 80-kVp scan and raw data-based iterative reconstruction for reduced iodine load abdominal-pelvic CT in patients at risk of contrast-induced nephropathy referred for oncological assessment: effects on radiation dose, image quality and renal function. Br J Radiol 2018; 91:20170632. [PMID: 29470108 DOI: 10.1259/bjr.20170632] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
OBJECTIVE To evaluate the image quality, radiation dose, and renal safety of contrast medium (CM)-reduced abdominal-pelvic CT combining 80-kVp and sinogram-affirmed iterative reconstruction (SAFIRE) in patients with renal dysfunction for oncological assessment. METHODS We included 45 patients with renal dysfunction (estimated glomerular filtration rate <45 ml per min per 1.73 m2) who underwent reduced-CM abdominal-pelvic CT (360 mgI kg-1, 80-kVp, SAFIRE) for oncological assessment. Another 45 patients without renal dysfunction (estimated glomerular filtration rate >60 ml per lmin per 1.73 m2) who underwent standard oncological abdominal-pelvic CT (600 mgI kg-1, 120-kVp, filtered-back projection) were included as controls. CT attenuation, image noise, and contrast-to-noise ratio (CNR) were compared. Two observers performed subjective image analysis on a 4-point scale. Size-specific dose estimate and renal function 1-3 months after CT were measured. RESULTS The size-specific dose estimate and iodine load of 80-kVp protocol were 32 and 41%,, respectively, lower than of 120-kVp protocol (p < 0.01). CT attenuation and contrast-to-noise ratio of parenchymal organs and vessels in 80-kVp images were significantly better than those of 120-kVp images (p < 0.05). There were no significant differences in quantitative or qualitative image noise or subjective overall quality (p > 0.05). No significant kidney injury associated with CM administration was observed. CONCLUSION 80-kVp abdominal-pelvic CT with SAFIRE yields diagnostic image quality in oncology patients with renal dysfunction under substantially reduced iodine and radiation dose without renal safety concerns. Advances in knowledge: Using 80-kVp and SAFIRE allows for 40% iodine load and 32% radiation dose reduction for abdominal-pelvic CT without compromising image quality and renal function in oncology patients at risk of contrast-induced nephropathy.
Collapse
Affiliation(s)
- Yasunori Nagayama
- 1 Department of Radiology, Kumamoto City Hospital , Kumamoto , Japan.,2 Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University , Kumamoto , Japan
| | - Shota Tanoue
- 1 Department of Radiology, Kumamoto City Hospital , Kumamoto , Japan.,2 Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University , Kumamoto , Japan
| | - Akinori Tsuji
- 1 Department of Radiology, Kumamoto City Hospital , Kumamoto , Japan
| | - Joji Urata
- 1 Department of Radiology, Kumamoto City Hospital , Kumamoto , Japan
| | | | - Seitaro Oda
- 2 Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University , Kumamoto , Japan
| | - Takeshi Nakaura
- 2 Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University , Kumamoto , Japan
| | - Daisuke Utsunomiya
- 2 Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University , Kumamoto , Japan
| | - Eri Yoshida
- 1 Department of Radiology, Kumamoto City Hospital , Kumamoto , Japan.,2 Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University , Kumamoto , Japan
| | - Morikatsu Yoshida
- 2 Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University , Kumamoto , Japan
| | - Masafumi Kidoh
- 2 Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University , Kumamoto , Japan
| | - Machiko Tateishi
- 1 Department of Radiology, Kumamoto City Hospital , Kumamoto , Japan.,2 Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University , Kumamoto , Japan
| | - Yasuyuki Yamashita
- 2 Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University , Kumamoto , Japan
| |
Collapse
|
41
|
Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning. Eur Radiol 2016; 27:1944-1953. [PMID: 27553939 DOI: 10.1007/s00330-016-4537-6] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2015] [Revised: 06/13/2016] [Accepted: 08/01/2016] [Indexed: 10/21/2022]
Abstract
PURPOSE To investigate feasibility, image quality and safety of low-tube-voltage, low-contrast-volume comprehensive cardiac and aortoiliac CT angiography (CTA) for planning transcatheter aortic valve replacement (TAVR). MATERIALS AND METHODS Forty consecutive TAVR candidates prospectively underwent combined CTA of the aortic root and vascular access route (270 mgI/ml iodixanol). Patients were assigned to group A (second-generation dual-source CT [DSCT], 100 kV, 60 ml contrast, 4.0 ml/s flow rate) or group B (third-generation DSCT, 70 kV, 40 ml contrast, 2.5 ml/s flow rate). Vascular attenuation, noise, signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were compared. Subjective image quality was assessed by two observers. Estimated glomerular filtration (eGFR) at CTA and follow-up were measured. RESULTS Besides a higher body-mass-index in group B (24.8±3.8 kg/m2 vs. 28.1±5.4 kg/m2, P=0.0339), patient characteristics between groups were similar (P≥0.0922). Aortoiliac SNR (P=0.0003) was higher in group B. Cardiac SNR (P=0.0003) and CNR (P=0.0181) were higher in group A. Subjective image quality was similar (P≥0.213) except for aortoiliac image noise (4.42 vs. 4.12, P=0.0374). TAVR-planning measurements were successfully obtained in all patients. There were no significant changes in eGFR among and between groups during follow-up (P≥0.302). CONCLUSION TAVR candidates can be safely and effectively evaluated by a comprehensive CTA protocol with low contrast volume using low-tube-voltage acquisition. KEY POINTS • Third-generation dual-source CT facilitates low-tube-voltage acquisition. • TAVR planning can be performed with reduced contrast volume and radiation dose. • TAVR-planning CT did not result in changes in creatinine levels at follow-up. • TAVR candidates can be safely evaluated by comprehensive low-tube-voltage CT angiography.
Collapse
|
42
|
Kok M, de Haan MW, Mihl C, Eijsvoogel NG, Hendriks BM, Sailer AM, Derks K, Schnerr RS, Schurink GWH, Wildberger JE, Das M. Individualized CT Angiography Protocols for the Evaluation of the Aorta: A Feasibility Study. J Vasc Interv Radiol 2016; 27:531-8. [DOI: 10.1016/j.jvir.2016.01.009] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2015] [Revised: 01/02/2016] [Accepted: 01/02/2016] [Indexed: 01/16/2023] Open
|
43
|
Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy. Eur Radiol 2016; 26:3802-3810. [DOI: 10.1007/s00330-016-4275-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2015] [Revised: 12/28/2015] [Accepted: 02/05/2016] [Indexed: 10/22/2022]
|