1
|
Chang S, Jung JI, Beck KS, Chang K, Kim Y, Han K. Diagnostic Efficacy and Safety of Low-Contrast-Dose Dual-Energy CT in Patients With Renal Impairment Undergoing Transcatheter Aortic Valve Replacement. Korean J Radiol 2024; 25:634-643. [PMID: 38942457 PMCID: PMC11214918 DOI: 10.3348/kjr.2023.1207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2023] [Revised: 05/09/2024] [Accepted: 05/10/2024] [Indexed: 06/30/2024] Open
Abstract
OBJECTIVE This study aimed to evaluate the diagnostic efficacy and safety of low-contrast-dose, dual-source dual-energy CT before transcatheter aortic valve replacement (TAVR) in patients with compromised renal function. MATERIALS AND METHODS A total of 54 consecutive patients (female:male, 26:38; 81.9 ± 7.3 years) with reduced renal function underwent pre-TAVR dual-energy CT with a 30-mL contrast agent between June 2022 and March 2023. Monochromatic (40- and 50-keV) and conventional (120-kVp) images were reconstructed and analyzed. The subjective quality score, vascular attenuation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were compared among the imaging techniques using the Friedman test and post-hoc analysis. Interobserver reliability for aortic annular measurement was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. The procedural outcomes and incidence of post-contrast acute kidney injury (AKI) were assessed. RESULTS Monochromatic images achieved diagnostic quality in all patients. The 50-keV images achieved superior vascular attenuation and CNR (P < 0.001 in all) while maintaining a similar SNR compared to conventional CT. For aortic annular measurement, the 50-keV images showed higher interobserver reliability compared to conventional CT: ICC, 0.98 vs. 0.90 for area and 0.97 vs. 0.95 for perimeter; 95% limits of agreement width, 0.63 cm² vs. 0.92 cm² for area and 5.78 mm vs. 8.50 mm for perimeter. The size of the implanted device matched CT-measured values in all patients, achieving a procedural success rate of 92.6%. No patient experienced a serum creatinine increase of ≥ 1.5 times baseline in the 48-72 hours following CT. However, one patient had a procedural delay due to gradual renal function deterioration. CONCLUSION Low-contrast-dose imaging with 50-keV reconstruction enables precise pre-TAVR evaluation with improved image quality and minimal risk of post-contrast AKI. This approach may be an effective and safe option for pre-TAVR evaluation in patients with compromised renal function.
Collapse
Affiliation(s)
- Suyon Chang
- Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Jung Im Jung
- Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
| | - Kyongmin Sarah Beck
- Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Kiyuk Chang
- Division of Cardiology, Department of Internal Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Yaeni Kim
- Division of Nephrology, Department of Internal Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Kyunghwa Han
- Department of Radiology, Research Institute of Radiological Science, and Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
2
|
Langenbach IL, Langenbach MC, Mayrhofer T, Foldyna B, Maintz D, Klein K, Wienemann H, Krug KB, Hellmich M, Adam M, Naehle CP. Reduction of contrast medium for transcatheter aortic valve replacement planning using a spectral detector CT: a prospective clinical trial. Eur Radiol 2024; 34:4089-4099. [PMID: 37979008 PMCID: PMC11166752 DOI: 10.1007/s00330-023-10403-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Revised: 08/25/2023] [Accepted: 09/17/2023] [Indexed: 11/19/2023]
Abstract
INTRODUCTION This study investigated the use of dual-energy spectral detector computed tomography (CT) and virtual monoenergetic imaging (VMI) reconstructions in pre-interventional transcatheter aortic valve replacement (TAVR) planning. We aimed to determine the minimum required contrast medium (CM) amount to maintain diagnostic CT imaging quality for TAVR planning. METHODS In this prospective clinical trial, TAVR candidates received a standardized dual-layer spectral detector CT protocol. The CM amount (Iohexol 350 mg iodine/mL, standardized flow rate 3 mL/s) was reduced systematically after 15 patients by 10 mL, starting at 60 mL (institutional standard). We evaluated standard, and 40- and 60-keV VMI reconstructions. For image quality, we measured signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and diameters in multiple vessel sections (i.e., aortic annulus: diameter, perimeter, area; aorta/arteries: minimal diameter). Mixed regression models (MRM), including interaction terms and clinical characteristics, were used for comparison. RESULTS Sixty consecutive patients (mean age, 79.4 ± 7.5 years; 28 females, 46.7%) were included. In pre-TAVR CT, the CM reduction to 40 mL is possible without affecting the image quality (MRM: SNR: -1.1, p = 0.726; CNR: 0.0, p = 0.999). VMI 40-keV reconstructions showed better results than standard reconstructions with significantly higher SNR (+ 6.04, p < 0.001). Reduction to 30 mL CM resulted in a significant loss of quality (MRM: SNR: -12.9, p < 0.001; CNR: -13.9, p < 0.001), regardless of the reconstruction. Across the reconstructions, we observed no differences in the metric evaluation (p > 0.914). CONCLUSION Among TAVR candidates undergoing pre-interventional CT at a dual-layer spectral detector system, applying 40 mL CM is sufficient to maintain diagnostic image quality. VMI 40-keV reconstructions improve the vessel attenuation and are recommended for evaluation. CLINICAL RELEVANCE STATEMENT Contrast medium reduction to 40 mL in pre-interventional transcatheter aortic valve replacement CT using dual-energy CT maintains image quality, while 40-keV virtual monoenergetic imaging reconstructions enhance vessel attenuation. These results offer valuable recommendations for interventional transcatheter aortic valve replacement evaluation and potentially improve nephroprotection in patients with compromised renal function. KEY POINTS • Patients undergoing transcatheter aortic valve replacement (TAVR), requiring pre-interventional CT, are often multimorbid with impaired renal function. • Using a spectral detector dual-layer CT, contrast medium reduction to 40 mL is feasible, maintaining diagnostic image quality. • The additional application of virtual monoenergetic image reconstructions with 40 keV improves vessel attenuation significantly in clinical practice.
Collapse
Affiliation(s)
- Isabel L Langenbach
- Cardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA, 02114, USA.
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany.
| | - Marcel C Langenbach
- Cardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA, 02114, USA
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany
| | - Thomas Mayrhofer
- Cardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA, 02114, USA
- School of Business Studies, Stralsund University of Applied Sciences, Stralsund, Germany
| | - Borek Foldyna
- Cardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA, 02114, USA
| | - David Maintz
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany
| | - Konstantin Klein
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany
| | - Hendrik Wienemann
- Clinic III for Internal Medicine, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany
| | - Kathrin B Krug
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany
| | - Martin Hellmich
- Institute of Medical Statistics and Computational Biology, Medical Faculty, University of Cologne, Cologne, Germany
| | - Matti Adam
- Clinic III for Internal Medicine, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany
| | | |
Collapse
|
3
|
Fontana F, Piacentino F, Gnesutta A, Macchi E, Coppola A, Saccomanno A, Gatta T, Recaldini C, Minenna M, Tamborini C, Dossi F, Ascenti V, Barbera S, Cicero G, Carcano G, Ascenti G, Castiglioni B, Venturini M. Transcatheter Aortic Valve Implantation (TAVI) Planning with Dual-Layer Spectral CT Using Virtual Monoenergetic Image (VMI) Reconstructions and 20 mL of Contrast Media. J Clin Med 2024; 13:524. [PMID: 38256659 PMCID: PMC10816911 DOI: 10.3390/jcm13020524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 01/13/2024] [Accepted: 01/15/2024] [Indexed: 01/24/2024] Open
Abstract
Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to surgical implantation and its implementation is progressively increasing worldwide. We routinely perform pre-procedural aortic angiography CT to assess aortic dimensions and vascular anatomy. This study aims to evaluate the image quality of CTA for TAVI planning using dual-layer spectral CT, with virtual monoenergetic image reconstructions at 40 keV. Thirty-one patients underwent a CTA protocol with the injection of 20 mL of contrast media. Image quality was assessed by measuring the mean density in Hounsfield Units (HU), the signal-to-noise ratio, and the contrast-to-noise ratio in VMI reconstructions. Additionally, a blinded subjective analysis was conducted by two observers. The results showed significant enhancement at all sampled vascular levels with a gradual decrease in HU from proximal to distal regions. Favourable subjective ratings were given for all parameters, with greater variability in the evaluation of iliac axes. A significant negative correlation (p < 0.05) was observed between BMI and CA at all vascular levels, indicating reduced contrast enhancement with increasing BMI. Spectral CT, along with reducing iodine load, allows for obtaining high-quality images without a significant increase in noise. The reduction in iodine load can have positive implications in clinical practice, improving patient safety and resource efficiency.
Collapse
Affiliation(s)
- Federico Fontana
- Diagnostic and Interventional Radiology Unit, Circolo Hospital, ASST Sette Laghi, 21100 Varese, Italy; (F.F.); (A.G.); (E.M.); (A.S.); (T.G.); (C.R.); (M.V.)
- Postgraduate School of Radiology Technician, Insubria University, 21100 Varese, Italy;
| | - Filippo Piacentino
- Diagnostic and Interventional Radiology Unit, Circolo Hospital, ASST Sette Laghi, 21100 Varese, Italy; (F.F.); (A.G.); (E.M.); (A.S.); (T.G.); (C.R.); (M.V.)
| | - Aroa Gnesutta
- Diagnostic and Interventional Radiology Unit, Circolo Hospital, ASST Sette Laghi, 21100 Varese, Italy; (F.F.); (A.G.); (E.M.); (A.S.); (T.G.); (C.R.); (M.V.)
| | - Edoardo Macchi
- Diagnostic and Interventional Radiology Unit, Circolo Hospital, ASST Sette Laghi, 21100 Varese, Italy; (F.F.); (A.G.); (E.M.); (A.S.); (T.G.); (C.R.); (M.V.)
| | - Andrea Coppola
- Diagnostic and Interventional Radiology Unit, Circolo Hospital, ASST Sette Laghi, 21100 Varese, Italy; (F.F.); (A.G.); (E.M.); (A.S.); (T.G.); (C.R.); (M.V.)
| | - Angiola Saccomanno
- Diagnostic and Interventional Radiology Unit, Circolo Hospital, ASST Sette Laghi, 21100 Varese, Italy; (F.F.); (A.G.); (E.M.); (A.S.); (T.G.); (C.R.); (M.V.)
| | - Tonia Gatta
- Diagnostic and Interventional Radiology Unit, Circolo Hospital, ASST Sette Laghi, 21100 Varese, Italy; (F.F.); (A.G.); (E.M.); (A.S.); (T.G.); (C.R.); (M.V.)
| | - Chiara Recaldini
- Diagnostic and Interventional Radiology Unit, Circolo Hospital, ASST Sette Laghi, 21100 Varese, Italy; (F.F.); (A.G.); (E.M.); (A.S.); (T.G.); (C.R.); (M.V.)
| | - Manuela Minenna
- Postgraduate School of Radiology Technician, Insubria University, 21100 Varese, Italy;
| | - Claudio Tamborini
- Department of Cardiovascular Diseases, ASST Settelaghi, 21100 Varese, Italy; (C.T.); (F.D.); (B.C.)
| | - Filippo Dossi
- Department of Cardiovascular Diseases, ASST Settelaghi, 21100 Varese, Italy; (C.T.); (F.D.); (B.C.)
| | - Velio Ascenti
- Postgraduate School of Radiodiagnostics, Policlinico Universitario, University of Milan, 20133 Milano, Italy;
| | - Simone Barbera
- Diagnostic and Interventional Radiology Unit, Biomorf Department, University Hospital Messina, 98124 Messina, Italy; (S.B.); (G.C.); (G.A.)
| | - Giuseppe Cicero
- Diagnostic and Interventional Radiology Unit, Biomorf Department, University Hospital Messina, 98124 Messina, Italy; (S.B.); (G.C.); (G.A.)
| | - Giulio Carcano
- Department of Medicine and Technological Innovation, Insubria University, 21100 Varese, Italy;
| | - Giorgio Ascenti
- Diagnostic and Interventional Radiology Unit, Biomorf Department, University Hospital Messina, 98124 Messina, Italy; (S.B.); (G.C.); (G.A.)
| | - Battistina Castiglioni
- Department of Cardiovascular Diseases, ASST Settelaghi, 21100 Varese, Italy; (C.T.); (F.D.); (B.C.)
| | - Massimo Venturini
- Diagnostic and Interventional Radiology Unit, Circolo Hospital, ASST Sette Laghi, 21100 Varese, Italy; (F.F.); (A.G.); (E.M.); (A.S.); (T.G.); (C.R.); (M.V.)
- Department of Medicine and Technological Innovation, Insubria University, 21100 Varese, Italy;
| |
Collapse
|
4
|
Kazimierczak W, Kazimierczak N, Serafin Z. Review of Clinical Applications of Dual-Energy CT in Patients after Endovascular Aortic Repair. J Clin Med 2023; 12:7766. [PMID: 38137834 PMCID: PMC10743598 DOI: 10.3390/jcm12247766] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Revised: 12/08/2023] [Accepted: 12/16/2023] [Indexed: 12/24/2023] Open
Abstract
Abdominal aortic aneurysms (AAAs) are a significant cause of mortality in developed countries. Endovascular aneurysm repair (EVAR) is currently the leading treatment method for AAAs. Due to the high sensitivity and specificity of post-EVAR complication detection, CT angiography (CTA) is the reference method for imaging surveillance in patients after EVAR. Many studies have shown the advantages of dual-energy CT (DECT) over standard polyenergetic CTA in vascular applications. In this article, the authors briefly discuss the technical principles and summarize the current body of literature regarding dual-energy computed tomography angiography (DECTA) in patients after EVAR. The authors point out the most useful applications of DECTA in this group of patients and its advantages over conventional CTA. To conduct this review, a search was performed using the PubMed, Google Scholar, and Web of Science databases.
Collapse
Affiliation(s)
- Wojciech Kazimierczak
- Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067 Bydgoszcz, Poland
- Kazimierczak Private Medical Practice, Dworcowa 13/u6a, 85-009 Bydgoszcz, Poland
| | - Natalia Kazimierczak
- Kazimierczak Private Medical Practice, Dworcowa 13/u6a, 85-009 Bydgoszcz, Poland
| | - Zbigniew Serafin
- Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067 Bydgoszcz, Poland
| |
Collapse
|
5
|
Rajiah PS, Kambadakone A, Ananthakrishnan L, Sutphin P, Kalva SP. Vascular Applications of Dual-Energy Computed Tomography. Radiol Clin North Am 2023; 61:1011-1029. [PMID: 37758354 DOI: 10.1016/j.rcl.2023.05.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/03/2023]
Abstract
Dual- or multi-energy CT imaging provides several advantages over conventional CT in the context of vascular imaging. Specific advantages include the use of low-energy virtual monoenergetic images (VMIs) to boost iodine attenuation to salvage suboptimal enhanced studies, perform low-contrast material dose studies, and increase conspicuity of small vessels and lesions. Alternatively, high-energy VMIs reduce artifacts caused by some metals, endoprosthesis, calcium blooming, and beam hardening. Virtual non-contrast (VNC) images reduce radiation dose by eliminating the need for a true non-contrast acquisition in multiphasic CT studies. Iodine maps can be used to evaluate perfusion of tissues and lesions.
Collapse
Affiliation(s)
- Prabhakar S Rajiah
- Department of Radiology, Mayo Clinic, 200 1st Street Southwest, Rochester, MN 55905, USA.
| | | | | | - Patrick Sutphin
- Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
| | - Sanjeeva P Kalva
- Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
| |
Collapse
|
6
|
Fahrni G, Mingas T, Deliessche A, Hraichi S, Rotzinger DC, Si-Mohamed SA, Boccalini S, Douek P. Low-iodine 40-keV virtual monoenergetic CT angiography of the lower extremities. Front Cardiovasc Med 2023; 10:1276738. [PMID: 37942065 PMCID: PMC10629994 DOI: 10.3389/fcvm.2023.1276738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2023] [Accepted: 09/25/2023] [Indexed: 11/10/2023] Open
Abstract
Introduction To evaluate a reduced iodine volume protocol for lower extremity CT angiography (CTA) using dual-energy CT (DECT). Methods This retrospective study included consecutive patients who underwent lower extremity CTA from June to December 2022. A 10 ml 1:1 mixed test bolus was performed, followed by a 40 ml full bolus at a 2.5/s injection rate, using 400 mg/ml iodine contrast media. Conventional and 40 keV virtual monoenergetic images (VMI) were reconstructed. For both reconstructions, five main artery segments were assessed with a 3-point image quality score as well as quantitative attenuation, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements with diagnostic quality thresholds (respectively >150 HU and >3). Results Forty patients were included in the study (mean age 68 ± 12 yo). 200 artery segments were assessed. Median qualitative image scores were 3 [IQR, 3, 3] for both reconstructions. 40 keV VMI upgraded qualitative scores for 51 (26%) of patients, including 9 (5%) from nondiagnostic to diagnostic quality. 40 keV VMI obtained attenuation and CNR diagnostic quality for respectively 100% and 100% of segments, compared with 96% and 98% for conventional images (p < 0.001). Distal artery segments showed the most differences between 40 keV VMI and conventional images. Conclusion A low-iodine lower extremity CTA protocol is feasible, with 40 keV virtual monoenergetic spectral reconstruction enabling maintained diagnostic image quality at the distal artery segments.
Collapse
Affiliation(s)
- Guillaume Fahrni
- Department of Diagnostic and Interventional Radiology, Cardiothoracic and Vascular Division, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, Villeurbanne, France
- Department of Radiology, Hôpital Louis Pradel, Hospices Civils de Lyon, Bron, France
| | - Thomas Mingas
- University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, Villeurbanne, France
- Department of Radiology, Hôpital Louis Pradel, Hospices Civils de Lyon, Bron, France
| | - Arthur Deliessche
- University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, Villeurbanne, France
- Department of Radiology, Hôpital Louis Pradel, Hospices Civils de Lyon, Bron, France
| | - Smail Hraichi
- University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, Villeurbanne, France
- Department of Radiology, Hôpital Louis Pradel, Hospices Civils de Lyon, Bron, France
| | - David C. Rotzinger
- Department of Diagnostic and Interventional Radiology, Cardiothoracic and Vascular Division, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Salim A. Si-Mohamed
- University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, Villeurbanne, France
- Department of Radiology, Hôpital Louis Pradel, Hospices Civils de Lyon, Bron, France
| | - Sara Boccalini
- University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, Villeurbanne, France
- Department of Radiology, Hôpital Louis Pradel, Hospices Civils de Lyon, Bron, France
| | - Philippe Douek
- University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, Villeurbanne, France
- Department of Radiology, Hôpital Louis Pradel, Hospices Civils de Lyon, Bron, France
| |
Collapse
|
7
|
Higashigaito K, Mergen V, Eberhard M, Jungblut L, Hebeisen M, Rätzer S, Zanini B, Kobe A, Martini K, Euler A, Alkadhi H. CT Angiography of the Aorta Using Photon-counting Detector CT with Reduced Contrast Media Volume. Radiol Cardiothorac Imaging 2023; 5:e220140. [PMID: 36860835 PMCID: PMC9969214 DOI: 10.1148/ryct.220140] [Citation(s) in RCA: 54] [Impact Index Per Article: 27.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2022] [Revised: 12/04/2022] [Accepted: 12/14/2022] [Indexed: 01/27/2023]
Abstract
Purpose To develop and evaluate a low-volume contrast media protocol for thoracoabdominal CT angiography (CTA) with photon-counting detector (PCD) CT. Materials and Methods This prospective study included consecutive participants (April-September 2021) who underwent CTA with PCD CT of the thoracoabdominal aorta and previous CTA with energy-integrating detector (EID) CT at equal radiation doses. In PCD CT, virtual monoenergetic images (VMI) were reconstructed in 5-keV intervals from 40 to 60 keV. Attenuation of the aorta, image noise, and contrast-to-noise ratio (CNR) were measured, and subjective image quality was rated by two independent readers. In the first group of participants, the same contrast media protocol was used for both scans. CNR gain in PCD CT compared with EID CT served as the reference for contrast media volume reduction in the second group. Noninferiority analysis was used to test noninferior image quality of the low-volume contrast media protocol with PCD CT. Results The study included 100 participants (mean age, 75 years ± 8 [SD]; 83 men). In the first group (n = 40), VMI at 50 keV provided the best trade-off between objective and subjective image quality, achieving 25% higher CNR compared with EID CT. Contrast media volume in the second group (n = 60) was reduced by 25% (52.5 mL). Mean differences in CNR and subjective image quality between EID CT and PCD CT at 50 keV were above the predefined boundaries of noninferiority (-0.54 [95% CI: -1.71, 0.62] and -0.36 [95% CI: -0.41, -0.31], respectively). Conclusion CTA of the aorta with PCD CT was associated with higher CNR, which was translated into a low-volume contrast media protocol demonstrating noninferior image quality compared with EID CT at the same radiation dose.Keywords: CT Angiography, CT-Spectral, Vascular, Aorta, Contrast Agents-Intravenous, Technology Assessment© RSNA, 2023See also the commentary by Dundas and Leipsic in this issue.
Collapse
Affiliation(s)
- Kai Higashigaito
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zürich, Switzerland (K.H., V.M., M.E., L.J., S.R., B.Z., A.K., K.M., A.E., H.A.); and Department of Biostatistics at Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Switzerland (M.H.)
| | - Victor Mergen
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zürich, Switzerland (K.H., V.M., M.E., L.J., S.R., B.Z., A.K., K.M., A.E., H.A.); and Department of Biostatistics at Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Switzerland (M.H.)
| | - Matthias Eberhard
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zürich, Switzerland (K.H., V.M., M.E., L.J., S.R., B.Z., A.K., K.M., A.E., H.A.); and Department of Biostatistics at Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Switzerland (M.H.)
| | - Lisa Jungblut
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zürich, Switzerland (K.H., V.M., M.E., L.J., S.R., B.Z., A.K., K.M., A.E., H.A.); and Department of Biostatistics at Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Switzerland (M.H.)
| | - Monika Hebeisen
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zürich, Switzerland (K.H., V.M., M.E., L.J., S.R., B.Z., A.K., K.M., A.E., H.A.); and Department of Biostatistics at Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Switzerland (M.H.)
| | - Susan Rätzer
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zürich, Switzerland (K.H., V.M., M.E., L.J., S.R., B.Z., A.K., K.M., A.E., H.A.); and Department of Biostatistics at Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Switzerland (M.H.)
| | - Bettina Zanini
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zürich, Switzerland (K.H., V.M., M.E., L.J., S.R., B.Z., A.K., K.M., A.E., H.A.); and Department of Biostatistics at Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Switzerland (M.H.)
| | - Adrian Kobe
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zürich, Switzerland (K.H., V.M., M.E., L.J., S.R., B.Z., A.K., K.M., A.E., H.A.); and Department of Biostatistics at Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Switzerland (M.H.)
| | - Katharina Martini
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zürich, Switzerland (K.H., V.M., M.E., L.J., S.R., B.Z., A.K., K.M., A.E., H.A.); and Department of Biostatistics at Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Switzerland (M.H.)
| | - André Euler
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zürich, Switzerland (K.H., V.M., M.E., L.J., S.R., B.Z., A.K., K.M., A.E., H.A.); and Department of Biostatistics at Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Switzerland (M.H.)
| | - Hatem Alkadhi
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zürich, Switzerland (K.H., V.M., M.E., L.J., S.R., B.Z., A.K., K.M., A.E., H.A.); and Department of Biostatistics at Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Switzerland (M.H.)
| |
Collapse
|
8
|
Kaproth-Joslin K, Hobbs S, Rajiah P, Chaturvedi A, Chaturvedi A. Optimizing low contrast volume thoracic CT angiography: From the basics to the advanced. J Clin Imaging Sci 2022; 12:41. [PMID: 36128360 PMCID: PMC9479554 DOI: 10.25259/jcis_51_2022] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Accepted: 06/30/2022] [Indexed: 11/04/2022] Open
Abstract
Contrast-enhanced CT angiography (CTA) is a widely used, noninvasive imaging technique for evaluating cardiovascular structures. Contrast-induced nephrotoxicity is a concern in renal disease; however, the true nephrotoxic potential of iodinated contrast media (CM) is unknown. If a renal impaired patient requires CTA, it is important to protect the kidneys from further harm by reducing total iodinated CM volume while still obtaining diagnostic quality imaging. These same reduced volume CM techniques can also be applied to nonrenal impaired patients in times of CM shortage. This educational review discusses several modifications to CTA that can be adapted to both conventional 64-slice and the newer generation CT scanners which enable subsecond acquisition with a reduced CM volume technique. Such modifications include hardware and software adjustments and changes to both the volume and flow rate of administered CM, with the goal to reduce the dose of CM without compromising diagnostic yield.
Collapse
Affiliation(s)
| | - Susan Hobbs
- Department of Imaging Sciences, University of Rochester, Rochester, New York, United States
| | - Prabhakar Rajiah
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, United States
| | - Apeksha Chaturvedi
- Department of Imaging Sciences, University of Rochester, Rochester, New York, United States
| | - Abhishek Chaturvedi
- Department of Imaging Sciences, University of Rochester, Rochester, New York, United States
| |
Collapse
|
9
|
Euler A, Higashigaito K, Mergen V, Sartoretti T, Zanini B, Schmidt B, Flohr TG, Ulzheimer S, Eberhard M, Alkadhi H. High-Pitch Photon-Counting Detector Computed Tomography Angiography of the Aorta: Intraindividual Comparison to Energy-Integrating Detector Computed Tomography at Equal Radiation Dose. Invest Radiol 2022; 57:115-121. [PMID: 34352805 DOI: 10.1097/rli.0000000000000816] [Citation(s) in RCA: 106] [Impact Index Per Article: 35.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE The aims of this study were to determine the objective and subjective image quality of high-pitch computed tomography (CT) angiography of the aorta in clinical dual-source photon-counting detector CT (PCD-CT) and to compare the image quality to conventional dual-source energy-integrating detector CT (EID-CT) in the same patients at equal radiation dose. MATERIALS AND METHODS Patients with prior CT angiography of the thoracoabdominal aorta acquired on third-generation dual-source EID-CT in the high-pitch mode and with automatic tube voltage selection (ATVS, reference tube voltage 100 kV) were included. Follow-up imaging was performed on a first-generation, clinical dual-source PCD-CT scanner in the high-pitch and multienergy (QuantumPlus) mode at 120 kV using the same contrast media protocol as with EID-CT. Radiation doses between scans were matched by adapting the tube current of PCD-CT. Polychromatic images for both EID-CT and PCD-CT (called T3D) and virtual monoenergetic images at 40, 45, 50, and 55 keV for PCD-CT were reconstructed. Computed tomography attenuation was measured in the aorta; noise was defined as the standard deviation of attenuation; contrast-to-noise ratio (CNR) was calculated. Subjective image quality (noise, vessel attenuation, vessel sharpness, and overall quality) was rated by 2 blinded, independent radiologists. RESULTS Forty patients were included (mean age, 63 years; 8 women; mean body mass index [BMI], 26 kg/m2). There was no significant difference in BMI, effective diameter, or radiation dose between scans (all P's > 0.05). The ATVS in EID-CT selected 70, 80, 90, 100, 110, and 120 kV in 2, 14, 14, 7, 2, and 1 patients, respectively. Mean CNR was 17 ± 8 for EID-CT and 22 ± 7, 20 ± 6, 18 ± 5, 16 ± 5, and 12 ± 4 for PCD-CT at 40, 45, 50, 55 keV, and T3D, respectively. Contrast-to-noise ratio was significantly higher for 40 and 45 keV of PCD-CT as compared with EID-CT (both P's < 0.05). The linear regression model (adjusted R2, 0.38; P < 0.001) revealed that PCD-CT reconstruction (P < 0.001), BMI group (P = 0.007), and kV of the EID-CT scan (P = 0.01) were significantly associated with CNR difference, with an increase by 34% with PCD-CT for overweight as compared with normal weight patients. Subjective image quality reading revealed slight differences between readers for subjective vessel attenuation and sharpness, whereas subjective noise was rated significantly higher for 40 and 45 keV (P < 0.001) and overall quality similar (P > 0.05) between scans. CONCLUSIONS High-pitch PCD-CT angiography of the aorta with VMI at 40 and 45 keV resulted in significantly increased CNR compared with EID-CT with ATVS at matched radiation dose. The CNR gain of PCD-CT increased in overweight patients. Taking into account the subjective analysis, VMI at 45 to 50 keV is proposed as the best trade-off between objective and subjective image quality.
Collapse
Affiliation(s)
- André Euler
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich, Zurich, Switzerland
| | - Kai Higashigaito
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich, Zurich, Switzerland
| | - Victor Mergen
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich, Zurich, Switzerland
| | | | - Bettina Zanini
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich, Zurich, Switzerland
| | | | | | | | - Matthias Eberhard
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich, Zurich, Switzerland
| | - Hatem Alkadhi
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
10
|
Zeng Y, Geng D, Zhang J. Noise-optimized virtual monoenergetic imaging technology of the third-generation dual-source computed tomography and its clinical applications. Quant Imaging Med Surg 2021; 11:4627-4643. [PMID: 34737929 DOI: 10.21037/qims-20-1196] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2020] [Accepted: 06/02/2021] [Indexed: 02/05/2023]
Abstract
The third-generation dual-source computed tomography (DSCT) is among the most advanced imaging methods. It employs noise-optimized virtual monoenergetic imaging (VMI+) technology. It uses the frequency-split method to extract high-contrast image information from low-energy images and low-noise information from images reconstructed at an optimal energy level, combining them to obtain the final image with improved quality. This review is the first to summarize the results of clinical studies that primarily and recently evaluated the VMI+ technique based on tumor, blood vessel, and other lesion classification. We aim to assist radiologists in quickly selecting the appropriate energy level when performing image reconstruction for superior image quality in clinical work and providing several ideas for future scientific research of the VMI+ technique. Presently, VMI+ reconstruction is mostly used for images of various tumors or blood vessels, including coronary plaques, coronary stents, deep vein thromboses, pulmonary embolisms (PEs), active arterial hemorrhages, and endoleaks after endovascular aneurysm repair. In addition, VMI+ has been used for imaging children's heads, liver lesions, pancreatic lacerations, and reducing metal artifacts. Regarding the reconstruction at the optimal energy level, the VMI+ technique yielded a higher image quality than the pre-optimized virtual monoenergetic imaging (VMI) technique and single-energy CT. Moreover, either low concentrations of contrast medium or low iodine injection rates can be applied before VMI+ reconstruction at a low-energy level to reduce contrast agent-related kidney injury risk. After reconstructing an image at the optimal energy level, both the image's window width and level can also be adjusted to improve the image effect's reach and diagnosis suitability. To improve image quality and lesion-imaging clarity and reduce the use of contrast agents, VMI+ reconstruction technology has been applied clinically, in which the selection of energy level is the key to the whole reconstruction process. Our review summarizes these optimal levels for radiologists' reference and suggests new ideas for the direction of future VMI+ research.
Collapse
Affiliation(s)
- Yanwei Zeng
- Department of Radiology, Huashan Hospital, Fudan University, Shanghai, China.,Institute of Functional and Molecular Medical Imaging, Fudan University, Shanghai, China.,Center for Shanghai Intelligent Imaging for Critical Brain Diseases Engineering and Technology Research, Shanghai, China
| | - Daoying Geng
- Department of Radiology, Huashan Hospital, Fudan University, Shanghai, China.,Institute of Functional and Molecular Medical Imaging, Fudan University, Shanghai, China.,Center for Shanghai Intelligent Imaging for Critical Brain Diseases Engineering and Technology Research, Shanghai, China
| | - Jun Zhang
- Department of Radiology, Huashan Hospital, Fudan University, Shanghai, China.,Institute of Functional and Molecular Medical Imaging, Fudan University, Shanghai, China.,Center for Shanghai Intelligent Imaging for Critical Brain Diseases Engineering and Technology Research, Shanghai, China
| |
Collapse
|
11
|
Shen H, Yuan X, Liu D, Tu C, Wang X, Liu R, Wang X, Lan X, Fu K, Zhang J. Multiparametric dual-energy CT to differentiate stage T1 nasopharyngeal carcinoma from benign hyperplasia. Quant Imaging Med Surg 2021; 11:4004-4015. [PMID: 34476185 DOI: 10.21037/qims-20-1269] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Accepted: 04/19/2021] [Indexed: 12/30/2022]
Abstract
Background Stage T1 nasopharyngeal carcinoma (NPCT1) and benign hyperplasia (BH) are 2 common causes of nasopharyngeal mucosa/submucosa thickening without specific clinical symptoms. The treatment management of these 2 entities is significantly different. Reliable differentiation between the 2 entities is critical for the treatment decision and prognosis of patients. Therefore, our study aims to explore the optimal energy level of noise-optimized virtual monoenergetic images [VMI (+)] derived from dual-energy computed tomography (DECT) to display NPCT1 and BH and to explore the clinical value of DECT for differentiating these 2 diseases. Methods A total of 91 patients (44 NPCT1, 47 BH) were enrolled. The demarcation of the lesion margins and overall image quality, noise, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were evaluated for 40-80 kiloelectron volts (keV) VMIs (+) and polyenergetic images in the contrast-enhanced phase. Image features were assessed in the contrast-enhanced images with optimal visualization of NPCT1 and BH. The demarcation of NPCT1 and BH in iodine-water maps was also assessed. The contrast-enhanced images were used to calculate the slope of the spectral Hounsfield unit curve (λHU) and normalized iodine concentration (NIC). The nonenhanced phase images were used to calculate the normalized effective atomic number (NZeff). The attenuation values on 40-80 keV VMIs (+) in the contrast-enhanced phase were recorded. The diagnostic performance was assessed using receiver operating characteristic (ROC) curve analysis. Results The 40 keV VMI (+) in the enhanced phase yielded higher demarcation of the lesion margins scores, overall image quality scores, noise, SNR, and CNR values than 50-80 keV VMIs (+) and polyenergetic images. NPCT1 yielded higher attenuation values on VMI (+) at 40 keV (A40), NIC, λHU, and NZeff values than BH. The multivariate logistic regression model combining image features (tumor symmetry) with quantitative parameters (A40, NIC, λHU, and NZeff) yielded the best performance for differentiating the 2 diseases (AUC: 0.963, sensitivity: 89.4%, specificity: 93.2%). Conclusions The combination of DECT-derived image features and quantitative parameters contributed to the differentiation between NPCT1 and BH.
Collapse
Affiliation(s)
- Hesong Shen
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing, China
| | - Xiaoqian Yuan
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing, China
| | - Daihong Liu
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing, China
| | - Chunrong Tu
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing, China
| | - Xing Wang
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing, China
| | - Renwei Liu
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing, China
| | - Xiaoxia Wang
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing, China
| | - Xiaosong Lan
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing, China
| | - Kaiwen Fu
- Department of Pathology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing, China
| | - Jiuquan Zhang
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing, China
| |
Collapse
|
12
|
Shen H, Yuan X, Liu D, Huang Y, Wang Y, Jiang S, Zhang J. Multiparametric dual-energy CT for distinguishing nasopharyngeal carcinoma from nasopharyngeal lymphoma. Eur J Radiol 2021; 136:109532. [PMID: 33450663 DOI: 10.1016/j.ejrad.2021.109532] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Revised: 12/09/2020] [Accepted: 01/05/2021] [Indexed: 01/30/2023]
Abstract
OBJECTIVES To determine the optimal kiloelectron volt of noise-optimized virtual monoenergetic images [VMI (+)] for visualization of nasopharyngeal carcinoma (NPC) and nasopharyngeal lymphoma (NPL), and to explore the clinical value of quantitative parameters derived from dual-energy computed tomography (DECT) for distinguishing the two entities. MATERIALS AND METHODS Eighty patients including 51 with NPC and 29 with NPL were enrolled. The VMIs (+) at 40-80 keV with an interval of 10 keV were reconstructed by contrast enhanced images. The overall image quality and demarcation of lesion margins, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were assessed in VMIs (+) and polyenergetic images (PEI). Normalized iodine concentration (NIC), slope of the spectral Hounsfield unit curve (λHU) and effective atomic number (Zeff) were calculated. Diagnostic performance was assessed by receiver operating characteristic (ROC) curve. RESULTS The 40 keV VMI (+) yielded highest overall image quality scores, demarcation of lesion margins scores, SNR and CNR. The values of NIC, λHU and Zeff in NPL were higher than those in NPC (P < 0.001). Multivariate logistic regression model combining NIC, λHU and Zeff showed the best performance for distinguishing NPC from NPL (AUC: 0.947, sensitivity: 93.1 % and specificity: 92.2 %). CONCLUSION VMI (+) reconstruction at 40 keV was optimal for visualizing NPC and NPL. Quantitative parameters derived from DECT were helpful for differentiating NPC from NPL.
Collapse
Affiliation(s)
- Hesong Shen
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, No. 181 Hanyu Road, Shapingba District, Chongqing, 400030, PR China
| | - Xiaoqian Yuan
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, No. 181 Hanyu Road, Shapingba District, Chongqing, 400030, PR China
| | - Daihong Liu
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, No. 181 Hanyu Road, Shapingba District, Chongqing, 400030, PR China
| | - Yuanying Huang
- Department of Oncology and Hematology, Chongqing General Hospital, No. 104 Pipashan Street, Yuzhong District, Chongqing, 400014, PR China
| | - Yu Wang
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, No. 181 Hanyu Road, Shapingba District, Chongqing, 400030, PR China
| | - Shixi Jiang
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, No. 181 Hanyu Road, Shapingba District, Chongqing, 400030, PR China
| | - Jiuquan Zhang
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, No. 181 Hanyu Road, Shapingba District, Chongqing, 400030, PR China.
| |
Collapse
|
13
|
D'Angelo T, Lenga L, Arendt CT, Bucher AM, Peterke JL, Caruso D, Mazziotti S, Ascenti G, Blandino A, Othman AE, Martin SS, Albrecht MH, Bodelle B, Vogl TJ, Wichmann JL. Carotid and cerebrovascular dual-energy computed tomography angiography: Optimization of window settings for virtual monoenergetic imaging reconstruction. Eur J Radiol 2020; 130:109166. [PMID: 32693314 DOI: 10.1016/j.ejrad.2020.109166] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2019] [Revised: 04/25/2020] [Accepted: 07/05/2020] [Indexed: 02/08/2023]
Abstract
PURPOSE Dedicated post-processing of dual-energy computed tomography angiography (DE-CTA) datasets has been shown to allow for increased vascular contrast. The goal of our study was to define optimal window settings for displaying virtual monoenergetic images (VMI) reconstructed from dual-energy carotid and cerebrovascular DE-CTA. METHODS Fifty-seven patients who underwent clinically-indicated carotid and cerebrovascular third-generation dual-source DE-CTA were retrospectively evaluated. Standard linearly-blended (M_0.6), 70-keV traditional VMI (M70), and 40-keV noise-optimized VMI (M40+) reconstructions were analyzed. For M70 and M40+ datasets, the subjectively best window setting (width and level, B-W/L) was independently determined by two observers and subsequently related with aortic arch attenuation to calculate optimized values (O-W/L) using linear regression. Subjective evaluation of image quality (IQ) between W/L settings were assessed by two additional readers. Repeated measures analysis of variance were performed to compare W/L settings and IQ indices between M_0.6, M70, and M40 + . RESULTS B-W/L and O-W/L for M70 were 580/210 and 560/200, and for M40+ were 1630/570 and 1560/550, respectively, higher than standard DE-CTA W/L settings (450/100). Highest subjective scores were observed for M40+ regarding overall IQ (all p < 0.001). CONCLUSION Application of O-W/L settings is mandatory to optimize subjective IQ of VMI reconstructions of DE-CTA.
Collapse
Affiliation(s)
- Tommaso D'Angelo
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany; Department of Biomedical Sciences and Morphological and Functional Imaging, "G. Martino" University Hospital Messina, Via Consolare Valeria 1, 98100, Messina, Italy
| | - Lukas Lenga
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Christophe T Arendt
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Andreas M Bucher
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Julia L Peterke
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Damiano Caruso
- Department of Radiological Sciences, Oncological and Pathological Sciences, "La Sapienza'' University Hospital, Latina, Italy
| | - Silvio Mazziotti
- Department of Biomedical Sciences and Morphological and Functional Imaging, "G. Martino" University Hospital Messina, Via Consolare Valeria 1, 98100, Messina, Italy
| | - Giorgio Ascenti
- Department of Biomedical Sciences and Morphological and Functional Imaging, "G. Martino" University Hospital Messina, Via Consolare Valeria 1, 98100, Messina, Italy
| | - Alfredo Blandino
- Department of Biomedical Sciences and Morphological and Functional Imaging, "G. Martino" University Hospital Messina, Via Consolare Valeria 1, 98100, Messina, Italy
| | - Ahmed E Othman
- Department for Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, University Hospital Tübingen, Tübingen, Germany
| | - Simon S Martin
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Moritz H Albrecht
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Boris Bodelle
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Thomas J Vogl
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Julian L Wichmann
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany.
| |
Collapse
|
14
|
Schwartz FR, Tailor T, Gaca JG, Kiefer T, Harrison K, Hughes GC, Ramirez-Giraldo JC, Marin D, Hurwitz LM. Impact of dual energy cardiac CT for metal artefact reduction post aortic valve replacement. Eur J Radiol 2020; 129:109135. [PMID: 32590257 DOI: 10.1016/j.ejrad.2020.109135] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2019] [Revised: 06/12/2020] [Accepted: 06/15/2020] [Indexed: 11/28/2022]
Abstract
PURPOSE Assess image quality of dual-energy (DE) and single-energy (SE) cardiac multi-detector computed tomographic (MDCT) post aortic valve replacement (AVR) on a dual source MDCT scanner. METHODS Eighty patients with cardiac MDCT acquisitions (ECG gated, dual-source) post-surgical and transcatheter AVR were retrospectively identified. Forty DE (cohort 1) and 40 SE acquisitions (cohort 2; 100 or 120 kVp) were reviewed. Metal artefact at valve coaptation (VC) and valve insertion site (VIS), and contrast enhancement were assessed. Valve leaflet edge definition was graded on a 4-point scale by three radiologists. RESULTS The mean percentage valve area obscured by metal artifact differed between the cohorts; cohort 1 DE blended, high keV and low keV: 14.8 %, 11.1 % and 17.8 % at VC and 16.4 %, 13 %, 20.4 % at VIS respectively. Cohort 2: 25.8 % and 33.6 % (VC and VIS); each DE reconstruction vs SE: P < 0.0001. Average contrast opacification and coefficient of variance for cohort 1: 562.9 ± 144.7, 281.1 ± 60.3 and 1132.7 ± 300.8 Hounsfield Units (HU) and 9.6 %, 10 % and 8.9 %. For cohort 2: 437.2 ± 119.2 HU and 10.8 % (P < 0.01). Average leaflet edge definition cohort 1: 2.3 ± 0.4, 2.7 ± 0.2 and 2.3 ± 0.2, and cohort 2: 2.9 ± 0.2. CONCLUSION DE high keV renderings can result in up to 17.2 % less metal artefact compared to standard SE acquisition for cardiac CT. Contrast opacification and homogeneity is higher for DE blended and low keV renderings compared to SE acquisition with leaflet visibility preferred for low keV and blended DE renderings.
Collapse
Affiliation(s)
- Fides Regina Schwartz
- Department of Radiology, Duke University Medical Center, Durham, NC 27705, United States.
| | - Tina Tailor
- Department of Radiology, Duke University Medical Center, Durham, NC 27705, United States
| | - Jeffrey G Gaca
- Department of Cardiothoracic Surgery, Duke University Medical Center, Durham, NC 27705, United States
| | - Todd Kiefer
- Department of Cardiology, Duke University Medical Center, Durham, NC 27705, United States
| | - Kevin Harrison
- Department of Cardiology, Duke University Medical Center, Durham, NC 27705, United States
| | - G Chad Hughes
- Department of Cardiothoracic Surgery, Duke University Medical Center, Durham, NC 27705, United States
| | | | - Daniele Marin
- Department of Radiology, Duke University Medical Center, Durham, NC 27705, United States
| | - Lynne M Hurwitz
- Department of Radiology, Duke University Medical Center, Durham, NC 27705, United States
| |
Collapse
|
15
|
Yucel-Finn A, Nicol E, Leipsic JA, Weir-McCall JR. CT in planning transcatheter aortic valve implantation procedures and risk assessment. Clin Radiol 2019; 76:73.e1-73.e19. [PMID: 31883615 DOI: 10.1016/j.crad.2019.11.015] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2019] [Accepted: 11/13/2019] [Indexed: 12/31/2022]
Abstract
For surgical aortic valve replacement, the Society of Thoracic Surgeons score (STSS) is the reference standard for the prediction of operative risk. In transcatheter aortic valve implantation (TAVI) though, where the procedure itself is minimally invasive, the traditional risk assessment is supplemented by CTA. Through a consistent approach to the acquisition of high-quality images and the standardised reporting of annular measurements and adverse root and vascular features, patients at risk of complications can be identified. In turn, this may allow for a personalised procedural approach and treatment strategies devised to potentially reduce or mitigate this risk. This article provides a systematic and standardised approach to pre-procedural work-up with computed tomography angiography (CTA) and explores the current state of evidence and future areas of development in this rapidly developing field.
Collapse
Affiliation(s)
| | - E Nicol
- Royal Brompton Hospital, London, UK
| | - J A Leipsic
- St Paul's Hospital, Vancouver, British Columbia, Canada
| | - J R Weir-McCall
- Royal Papworth Hospital, Cambridge, UK; University of Cambridge School of Clinical Medicine, Cambridge, UK.
| |
Collapse
|
16
|
Dual-energy computed tomography for evaluation of breast cancer: value of virtual monoenergetic images reconstructed with a noise-reduced monoenergetic reconstruction algorithm. Jpn J Radiol 2019; 38:154-164. [PMID: 31686294 DOI: 10.1007/s11604-019-00897-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2019] [Accepted: 10/24/2019] [Indexed: 01/11/2023]
Abstract
PURPOSE To evaluate the image quality and lesion visibility of virtual monoenergetic images (VMIs) reconstructed using a new monoenergetic reconstruction algorithm (nMERA) for evaluation of breast cancer. MATERIALS AND METHODS Forty-two patients with 46 breast cancers who underwent 4-phasic breast contrast-enhanced computed tomography (CT) using dual-energy CT (DECT) were enrolled. We selected the peak enhancement phase of the lesion in each patient. The selected phase images were generated by 120-kVp-equivalent linear blended (M120) and monoenergetic reconstructions from 40 to 80 keV using the standard reconstruction algorithm (sMERA: 40, 50, 60, 70, 80) and nMERA (40 +, 50 +, 60 +, 70 +, 80 +). The contrast-to-noise ratio (CNR) was calculated and objectively analyzed. Two independent readers subjectively scored tumor visibility and image quality each on a 5-point scale. RESULTS The CNR at 40 + and tumor visibility scores at 40 + and 50 + were significantly higher than those on M120. The CNR at 50 + was not significantly different from that on M120. However, the overall image quality score at 40 + was significantly lower than that at 50 + and on M120 (40 + vs M120, P < 0.0001 and 40 + vs 50 +, P = 0.0001). CONCLUSIONS VMI reconstructed with nMERA at 50 keV is preferable for evaluation of patients with breast cancer.
Collapse
|
17
|
Albrecht MH, Vogl TJ, Martin SS, Nance JW, Duguay TM, Wichmann JL, De Cecco CN, Varga-Szemes A, van Assen M, Tesche C, Schoepf UJ. Review of Clinical Applications for Virtual Monoenergetic Dual-Energy CT. Radiology 2019; 293:260-271. [DOI: 10.1148/radiol.2019182297] [Citation(s) in RCA: 71] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
18
|
Arendt CT, Czwikla R, Lenga L, Wichmann JL, Albrecht MH, Booz C, Martin SS, Leithner D, Tischendorf P, Blandino A, Vogl TJ, D'Angelo T. Improved coronary artery contrast enhancement using noise-optimised virtual monoenergetic imaging from dual-source dual-energy computed tomography. Eur J Radiol 2019; 122:108666. [PMID: 31786506 DOI: 10.1016/j.ejrad.2019.108666] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2019] [Revised: 09/04/2019] [Accepted: 09/12/2019] [Indexed: 01/15/2023]
Abstract
PURPOSE To define optimal kiloelectron volt (keV) settings for virtual monoenergetic imaging (VMI) reconstruction at dual-energy coronary computed tomography angiography (DE-CCTA). METHOD Fifty-one DE-CCTA data sets (33 men; mean age, 63.9 ± 13.2 years) were reconstructed as standard linearly-blended images (F_0.6; 60% of 90 kVp, 40% of 150 kVpSn), and with traditional (VMI) and noise-optimised (VMI+) algorithms from 40 to 100 keV in 10-keV intervals. Objective image quality was assessed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements. Three observers subjectively evaluated vascular contrast, image sharpness, noise and delineation of coronary plaques. RESULTS Median values for objective image analysis were highest in VMI + series at 40 keV (SNR, 44.5; CNR: 33.5), significantly superior (allp < 0.001) to the best VMI series at 70 keV (SNR, 28.1; CNR, 18.4) and standard F_0.6 images (SNR, 23.2; CNR, 15.6). Overall subjective metrics achieved higher scores at 40-keV VMI+ series in comparison to 70-keV VMI series and F_0.6 images (all p < 0.001), with optimal vascular contrast (5; ICC, 0.90), good image sharpness (4; 0.88), low noise (4; 0.82), and optimal plaque delineation (5; 0.89). CONCLUSIONS DE-CCTA image reconstruction with 40-keV VMI + allows for significant improvement of both objective and subjective image quality.
Collapse
Affiliation(s)
- Christophe T Arendt
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Rouben Czwikla
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Lukas Lenga
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Julian L Wichmann
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Moritz H Albrecht
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany.
| | - Christian Booz
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Simon S Martin
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany; Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA
| | - Doris Leithner
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Patricia Tischendorf
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Alfredo Blandino
- Section of Radiological Sciences, Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina, Messina, Italy
| | - Thomas J Vogl
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Tommaso D'Angelo
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany; Section of Radiological Sciences, Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina, Messina, Italy
| |
Collapse
|
19
|
Iuga AI, Doerner J, Siedek F, Haneder S, Byrtus J, Luetkens JA, Maintz D, Hickethier T. Computed tomography pulmonary angiograms using a novel dual-layer spectral detector: Adjusted window settings are essential for diagnostic image quality. Medicine (Baltimore) 2019; 98:e16606. [PMID: 31415352 PMCID: PMC6831234 DOI: 10.1097/md.0000000000016606] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
OBJECTIVE The aim of this study was to determine optimal window settings for conventional polyenergetic and virtual monoenergetic images derived from computed tomography pulmonary angiogram (CTPA) examinations of a novel dual-layer spectral detector computed tomography system (DLCT). METHODS Monoenergetic (40 keV) and polyenergetic images of 50 CTPA examinations were calculated and the best individual window width and level (W/L) values were manually assessed. Optimized values were obtained afterwards based on regression analysis. Diameters of standardized pulmonary artery segments and subjective image quality parameters were evaluated and compared. RESULTS Attenuation and contrast-to-noise values were higher in monoenergetic than in polyenergetic images (P≤.001). Averaged best individual W/L for polyenergetic and monoenergetic were 1020/170 and 2070/480 HU, respectively.All adjusted W/L-settings varied significantly compared to standard settings (700/100 HU) and obtained higher subjective image quality scores. A systematic overestimation of artery diameters for standard window settings in monoenergetic images was observed. CONCLUSIONS Appropriate W/L-settings are required to assess polyenergetic and monoenergetic CTPA images of a novel DLCT. W/L-settings of 1020/170 HU and 2070/480 HU were found to be the best averaged values for polyenergetic and monoenergetic CTPA images, respectively.
Collapse
Affiliation(s)
- Andra-Iza Iuga
- Institute of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne
| | - Jonas Doerner
- Institute of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne
| | - Florian Siedek
- Institute of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne
| | - Stefan Haneder
- Institute of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne
| | - Jonathan Byrtus
- Institute of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne
| | - Julian A. Luetkens
- Institute of Diagnostic and Interventional Radiology, University of Bonn, Bonn, Germany
| | - David Maintz
- Institute of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne
| | - Tilman Hickethier
- Institute of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne
| |
Collapse
|
20
|
Suntharalingam S, Stenzel E, Wetter A, Guberina N, Umutlu L, Schlosser T, Nassenstein K. Third generation dual-energy CT with 80/150 Sn kV for head and neck tumor imaging. Acta Radiol 2019; 60:586-592. [PMID: 30089396 DOI: 10.1177/0284185118788896] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Dual-energy CT (DECT) provides additional image datasets which enable improved tumor delineation or reduction of beam hardening artifacts in patients with head and neck squamous cell carcinoma (SCC). PURPOSE To assess radiation dose and image quality of third-generation DECT of the head and neck in comparison to single-energy CT (SECT). MATERIAL AND METHODS Thirty patients with SCC who underwent both SECT (reference tube voltage 120 kVp) and DECT (80/150 Sn kVp) of the head and neck region for staging were retrospectively selected. Attenuation measurements of the sternomastoid muscle, internal jugular vein, submandibular gland and tongue were compared. Image noise was assessed at five anatomic levels. Subjective image quality was evaluated by two radiologists in consensus. RESULTS CTDIvol was 55% lower with DECT (4.2 vs. 9.3 mGy; P = 0.002). Median image noise was equal or lower in DECT at all levels (nasopharynx: 3.9 vs. 5.8, P < 0.0001; floor of mouth: 3.6 vs. 4.5, P = 0.0002; arytenoids: 3.6 vs. 3.1, P = 0.096; lower thyroid: 4.4 vs. 5.7, P = 0.002; arch of aorta: 5.6 vs. 6.5, P = 0.001). Attenuation was significantly lower in DECT ( P < 0.05). Subjective image analysis revealed that DECT is equal or superior to SECT with regard to overall image quality (nasopharynx: 5 vs. 5, P = 1; floor of mouth: 5 vs. 5, P = 0.0041; arytenoids: 5 vs. 5, P = 0.6; lower thyroid: 5 vs. 3, P < 0.0001; arch of aorta: 5 vs. 4, P < 0.0001). CONCLUSION Head and neck imaging with third-generation DECT can reduce radiation dose by half compared to SECT, while maintaining excellent image quality.
Collapse
Affiliation(s)
- Saravanabavaan Suntharalingam
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Elena Stenzel
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Axel Wetter
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Nika Guberina
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Lale Umutlu
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Thomas Schlosser
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Kai Nassenstein
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| |
Collapse
|
21
|
Zeng Y, Deng K, Yang H, Tan Y, Liu J, Geng D, Zhang J. Noise-optimised virtual monoenergetic imaging of dual-energy CT: effect on metal artefact reduction in patients with lumbar internal fixation. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2019; 28:1783-1792. [PMID: 31041597 DOI: 10.1007/s00586-019-05984-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Revised: 04/09/2019] [Accepted: 04/19/2019] [Indexed: 10/26/2022]
Abstract
PURPOSE The purpose of this study was to evaluate the effects of noise-optimised virtual monoenergetic imaging (VMI+) reconstructions on reducing metal artefacts compared to traditional virtual monoenergetic imaging (VMI) and linearly blended (M_0.6) reconstructions in patients with lumbar metal internal fixation in dual-energy CT (DECT). METHODS Forty patients who underwent DECT were evaluated in this retrospective study. Images were reconstructed with M_0.6 and with VMI+ and VMI at 10-keV intervals from 40 keV to 190 keV. Attenuation and noise were measured in the hyperdense artefacts, hypodense artefacts, spinal canal, abdominal aorta (AA), and inferior vena cava (IVC). An artefact index (AI) was calculated. A subjective evaluation of the metal-bone interface, surrounding soft tissue, spinal canal, AA, and IVC was conducted. RESULTS The AI values for the hypodense artefacts, spinal canal, and IVC were lowest in the 130 keV VMI+ series, for the hyperdense artefacts in the 120 keV VMI+ series, and for the AA in the 190 keV VMI+ series. Except for the hypodense artefacts, the AI values were lower compared to the M_0.6 images and all the VMI series (all p < 0.05). The subjective image quality was highest at 130 keV VMI+ for the metal-bone interface, surrounding soft tissue, AA, and IVC, and at 120 keV VMI+ for the spinal canal. Except for the AA, these rating scores were higher compared to the M_0.6 images and the entire VMI series (all p < 0.05). CONCLUSIONS DECT with high-keV VMI+ efficiently reduces metal artefacts and shows superior image quality in patients with lumbar internal fixation. These slides can be retrieved from Electronic Supplementary Material.
Collapse
Affiliation(s)
- Yanwei Zeng
- Department of Radiology, Huashan Hospital, Fudan University, No.12 Wulumuqi Road (Middle), Shanghai, 200040, China
- Institute of Functional and Molecular Medical Imaging, Fudan University, No.12 Wulumuqi Road (Middle), Shanghai, 200040, China
| | - Kai Deng
- Department of Radiology, Second Xiangya Hospital, Central South University, Changsha, 410011, China
| | - Haitao Yang
- Department of Radiology, Second Xiangya Hospital, Central South University, Changsha, 410011, China
| | - Yi Tan
- Department of Radiology, Second Xiangya Hospital, Central South University, Changsha, 410011, China
| | - Jun Liu
- Department of Radiology, Second Xiangya Hospital, Central South University, Changsha, 410011, China.
| | - Daoying Geng
- Department of Radiology, Huashan Hospital, Fudan University, No.12 Wulumuqi Road (Middle), Shanghai, 200040, China
- Institute of Functional and Molecular Medical Imaging, Fudan University, No.12 Wulumuqi Road (Middle), Shanghai, 200040, China
| | - Jun Zhang
- Department of Radiology, Huashan Hospital, Fudan University, No.12 Wulumuqi Road (Middle), Shanghai, 200040, China.
- Institute of Functional and Molecular Medical Imaging, Fudan University, No.12 Wulumuqi Road (Middle), Shanghai, 200040, China.
| |
Collapse
|
22
|
D'Angelo T, Cicero G, Mazziotti S, Ascenti G, Albrecht MH, Martin SS, Othman AE, Vogl TJ, Wichmann JL. Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications. Br J Radiol 2019; 92:20180546. [PMID: 30919651 DOI: 10.1259/bjr.20180546] [Citation(s) in RCA: 85] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Dual energy CT (DECT) has evolved into a commonly applied imaging technique in clinical routine due to its unique post-processing opportunities for improved evaluation of all body areas. Reconstruction of virtual monoenergetic imaging (VMI) series has shown beneficial effects for both non-contrast and contrast-enhanced DECT due to the flexibility to calculate low-keV VMI reconstructions to increase contrast and iodine attenuation, or to compute high-keV VMI reconstructions to reduce beam-hardening artefacts. The goal of this review article is to explain the technical background of VMI and noise-optimized VMI+ algorithms and to give an overview of useful clinical applications of the VMI technique in DECT of various body regions.
Collapse
Affiliation(s)
- Tommaso D'Angelo
- 1 Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina , Messina , Italy.,2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| | - Giuseppe Cicero
- 1 Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina , Messina , Italy
| | - Silvio Mazziotti
- 1 Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina , Messina , Italy
| | - Giorgio Ascenti
- 1 Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina , Messina , Italy
| | - Moritz H Albrecht
- 2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| | - Simon S Martin
- 2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| | - Ahmed E Othman
- 3 Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tübingen , Tübingen , Germany
| | - Thomas J Vogl
- 2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| | - Julian L Wichmann
- 2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| |
Collapse
|
23
|
De Santis D, De Cecco CN, Schoepf UJ, Nance JW, Yamada RT, Thomas BA, Otani K, Jacobs BE, Turner DA, Wichmann JL, Eid M, Varga-Szemes A, Caruso D, Grant KL, Schmidt B, Vogl TJ, Laghi A, Albrecht MH. Modified calcium subtraction in dual-energy CT angiography of the lower extremity runoff: impact on diagnostic accuracy for stenosis detection. Eur Radiol 2019; 29:4783-4793. [PMID: 30805703 DOI: 10.1007/s00330-019-06032-y] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Revised: 12/21/2018] [Accepted: 01/22/2019] [Indexed: 01/18/2023]
Abstract
OBJECTIVES To investigate the diagnostic accuracy of a modified three-material decomposition calcium subtraction (CS) algorithm for the detection of arterial stenosis in dual-energy CT angiography (DE-CTA) of the lower extremity runoff compared to standard image reconstruction, using digital subtraction angiography (DSA) as the reference standard. METHODS Eighty-eight patients (53 males; mean age, 65.9 ± 11 years) with suspected peripheral arterial disease (PAD) who had undergone a DE-CTA examination of the lower extremity runoff between May 2014 and May 2015 were included in this IRB-approved, HIPAA-compliant retrospective study. Standard linearly blended and CS images were reconstructed and vascular contrast-to-noise ratios (CNR) were calculated. Two independent observers assessed subjective image quality using a 5-point Likert scale. Diagnostic accuracy for ≥ 50% stenosis detection was analyzed in a subgroup of 45 patients who had undergone additional DSA. Diagnostic accuracy parameters were estimated with a random-effects logistic regression analysis and compared using generalized estimating equations. RESULTS CS datasets showed higher CNR (15.3 ± 7.3) compared to standard reconstructions (13.5 ± 6.5, p < 0.001). Both reconstructions showed comparable qualitative image quality scores (CS, 4.64; standard, 4.57; p = 0.220). Diagnostic accuracy (sensitivity, specificity, positive and negative predictive values) for CS reconstructions was 96.5% (97.5%, 95.6%, 90.9%, 98.1) and 93.1% (98.8%, 90.4%, 82.3%, 99.1%) for standard images. CONCLUSIONS A modified three-material decomposition CS algorithm provides increased vascular CNR, equivalent qualitative image quality, and greater diagnostic accuracy for the detection of significant arterial stenosis of the lower extremity runoff on DE-CTA compared with standard image reconstruction. KEY POINTS • Calcified plaques may lead to overestimation of stenosis severity and false positive results, requiring additional invasive digital subtraction angiography (DSA). • A modified three-material decomposition algorithm for calcium subtraction provides greater diagnostic accuracy for the detection of significant arterial stenosis of the lower extremity runoff compared with standard image reconstruction. • The application of this algorithm in patients with heavily calcified vessels may be helpful to potentially reduce inconclusive CT angiography examinations and the need for subsequent invasive DSA.
Collapse
Affiliation(s)
- Domenico De Santis
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Department of Radiological Sciences, Oncology and Pathology, Sant'Andrea University Hospital, "Sapienza" - University of Rome, Rome, Italy
| | - Carlo N De Cecco
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA
| | - U Joseph Schoepf
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.
| | - John W Nance
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA
| | - Ricardo T Yamada
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA
| | - Brooke A Thomas
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA
| | - Katharina Otani
- Imaging and Therapy Systems Division, Healthcare Sector, Siemens Japan K.K., Tokyo, Japan
| | - Brian E Jacobs
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA
| | - D Alan Turner
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA
| | - Julian L Wichmann
- Division of Experimental and Translational Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Marwen Eid
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA
| | - Akos Varga-Szemes
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA
| | - Damiano Caruso
- Department of Radiological Sciences, Oncology and Pathology, Sant'Andrea University Hospital, "Sapienza" - University of Rome, Rome, Italy
| | | | - Bernhard Schmidt
- Division of Computed Tomography, Siemens Healthineers, Forchheim, Germany
| | - Thomas J Vogl
- Division of Experimental and Translational Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Andrea Laghi
- Department of Radiological Sciences, Oncology and Pathology, Sant'Andrea University Hospital, "Sapienza" - University of Rome, Rome, Italy
| | - Moritz H Albrecht
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Division of Experimental and Translational Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| |
Collapse
|
24
|
The Optimal Energy Level of Virtual Monochromatic Images From Spectral CT for Reducing Beam-Hardening Artifacts Due to Contrast Media in the Thorax. AJR Am J Roentgenol 2018; 211:557-563. [DOI: 10.2214/ajr.17.19377] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
25
|
Dane B, Patel H, O'Donnell T, Girvin F, Brusca-Augello G, Alpert JB, Niu B, Attia M, Babb J, Ko JP. Image Quality on Dual-energy CTPA Virtual Monoenergetic Images: Quantitative and Qualitative Assessment. Acad Radiol 2018; 25:1075-1086. [PMID: 29398436 DOI: 10.1016/j.acra.2017.12.012] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2017] [Revised: 12/08/2017] [Accepted: 12/17/2017] [Indexed: 01/14/2023]
Abstract
RATIONALE AND OBJECTIVES This study aims to determine the optimal photon energy for image quality of the pulmonary arteries (PAs) on dual-energy computed tomography (CT) pulmonary angiography (CTPA) utilizing low volumes of iodinated contrast. MATERIALS AND METHODS The study received institutional review board exemption and was Health Insurance Portability and Accountability Act compliant. Adults (n = 56) who underwent dual-energy CTPA with 50-60 cc of iodinated contrast on a third-generation dual-source multidetector CT were retrospectively and consecutively identified. Twelve virtual monoenergetic kiloelectron volt (keV) image data sets (40-150 keV, 10-keV increments) were generated with a second-generation noise-reducing algorithm. Standard regions of interest were placed on main, right, left, and right interlobar pulmonary arteries; pectoralis muscle; and extrathoracic air. Attenuation [mean CT number (Hounsfield unit, HU)], noise [standard deviation (HU)], signal to noise (SNR), and contrast to noise ratio were evaluated. Three blinded chest radiologists rated (from 1 to 5, with 5 being the best) randomized monoenergetic and weighted-average images for attenuation and noise. P <.05 was considered significant. RESULTS Region of interest mean CT number increased as keV decreased, with 40 keV having the highest value (P < .001). Mean SNR was highest for 40-60 keV (P <.05) (14.5-14.7) and was higher (P <.05) than all remaining energies (90-150 keV) for all vessel regions combined. Contrast to noise ratio was highest for 40 keV (P <.001) and decreased as keV increased. SNR was highest at 60 and 70 keV, only slightly higher than 40-50 keV (P <.05). Reader scores for 40-50 keV were greater than other energies and weighted-average images (P <.05). CONCLUSIONS Kiloelectron volt images of 40-50 keV from the second-generation algorithm optimize attenuation on dual-energy CTPA and can potentially aid in interpretation and avoiding nondiagnostic examinations.
Collapse
Affiliation(s)
- Bari Dane
- Department of Radiology, NYU Langone Health, 660 First Avenue, New York, NY 10016.
| | - Hersh Patel
- Department of Radiology, NYU Langone Health, 660 First Avenue, New York, NY 10016
| | | | - Francis Girvin
- Department of Radiology, NYU Langone Health, 660 First Avenue, New York, NY 10016
| | | | - Jeffrey B Alpert
- Department of Radiology, NYU Langone Health, 660 First Avenue, New York, NY 10016
| | - Bowen Niu
- Department of Radiology, NYU Langone Health, 660 First Avenue, New York, NY 10016
| | | | - James Babb
- Department of Radiology, NYU Langone Health, 660 First Avenue, New York, NY 10016
| | - Jane P Ko
- Department of Radiology, NYU Langone Health, 660 First Avenue, New York, NY 10016
| |
Collapse
|
26
|
De Santis D, Eid M, De Cecco CN, Jacobs BE, Albrecht MH, Varga-Szemes A, Tesche C, Caruso D, Laghi A, Schoepf UJ. Dual-Energy Computed Tomography in Cardiothoracic Vascular Imaging. Radiol Clin North Am 2018; 56:521-534. [PMID: 29936945 DOI: 10.1016/j.rcl.2018.03.010] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Dual energy computed tomography is becoming increasingly widespread in clinical practice. It can expand on the traditional density-based data achievable with single energy computed tomography by adding novel applications to help reach a more accurate diagnosis. The implementation of this technology in cardiothoracic vascular imaging allows for improved image contrast, metal artifact reduction, generation of virtual unenhanced images, virtual calcium subtraction techniques, cardiac and pulmonary perfusion evaluation, and plaque characterization. The improved diagnostic performance afforded by dual energy computed tomography is not associated with an increased radiation dose. This review provides an overview of dual energy computed tomography cardiothoracic vascular applications.
Collapse
Affiliation(s)
- Domenico De Santis
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, USA; Department of Radiological Sciences, Oncology and Pathology, University of Rome "Sapienza", Piazzale Aldo Moro 5, Rome 00185, Italy
| | - Marwen Eid
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, USA
| | - Carlo N De Cecco
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, USA
| | - Brian E Jacobs
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, USA
| | - Moritz H Albrecht
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, USA; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, Frankfurt am Main 60590, Germany
| | - Akos Varga-Szemes
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, USA
| | - Christian Tesche
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, USA; Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Lazarettstraße 36, Munich 80636, Germany
| | - Damiano Caruso
- Department of Radiological Sciences, Oncology and Pathology, University of Rome "Sapienza", Piazzale Aldo Moro 5, Rome 00185, Italy
| | - Andrea Laghi
- Department of Radiological Sciences, Oncology and Pathology, University of Rome "Sapienza", Piazzale Aldo Moro 5, Rome 00185, Italy
| | - Uwe Joseph Schoepf
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, USA.
| |
Collapse
|
27
|
Albrecht MH, De Cecco CN, Schoepf UJ, Spandorfer A, Eid M, De Santis D, Varga-Szemes A, van Assen M, von Knebel-Doeberitz PL, Tesche C, Puntmann VO, Nagel E, Vogl TJ, Nance JW. Dual-energy CT of the heart current and future status. Eur J Radiol 2018; 105:110-118. [PMID: 30017266 DOI: 10.1016/j.ejrad.2018.05.028] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Revised: 05/17/2018] [Accepted: 05/29/2018] [Indexed: 11/19/2022]
Abstract
Several applications utilizing dual-energy cardiac CT (DECT) have recently transitioned from the realm of research into clinical workflows. DECT acquisition techniques and subsequent post-processing can provide improved qualitative analysis, allow quantitative imaging, and have the potential to decrease requisite radiation and contrast material doses. Additionally, several experimental DECT techniques are pending further investigation and may improve the diagnostic accuracy of cardiac CT and/or provide evaluation of emerging imaging biomarkers in the future. This review article will summarize the major applications utilizing DECT in diagnosis of cardiovascular disease, including both the clinically used and investigational techniques examined to date.
Collapse
Affiliation(s)
- Moritz H Albrecht
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States; University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt, Germany.
| | - Carlo N De Cecco
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States.
| | - U Joseph Schoepf
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States.
| | - Adam Spandorfer
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States.
| | - Marwen Eid
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States.
| | - Domenico De Santis
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States; University of Rome "Sapienza", Department of Radiological Sciences, Oncological and Pathological Sciences, Latina, Italy.
| | - Akos Varga-Szemes
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States.
| | - Marly van Assen
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States; University Medical Center Groningen, Center for Medical Imaging, Department of Radiology, Groningen, The Netherlands.
| | - Philipp L von Knebel-Doeberitz
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States.
| | - Christian Tesche
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States; Heart Center Munich-Bogenhausen, Department of Cardiology and Intensive Care Medicine, Munich, Germany.
| | - Valentina O Puntmann
- University Hospital Frankfurt, Institute of Experimental and Translational Cardiovascular Imaging, DZHK Centre for Cardiovascular Imaging, Frankfurt, Germany.
| | - Eike Nagel
- University Hospital Frankfurt, Institute of Experimental and Translational Cardiovascular Imaging, DZHK Centre for Cardiovascular Imaging, Frankfurt, Germany.
| | - Thomas J Vogl
- University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt, Germany.
| | - John W Nance
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States.
| |
Collapse
|
28
|
Virtual Monoenergetic Images From a Novel Dual-Layer Spectral Detector Computed Tomography Scanner in Portal Venous Phase: Adjusted Window Settings Depending on Assessment Focus Are Essential for Image Interpretation. J Comput Assist Tomogr 2018; 42:350-356. [PMID: 29369944 DOI: 10.1097/rct.0000000000000711] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE We aimed to determine optimal window settings for conventional polyenergetic (PolyE) and virtual monoenergetic images (MonoE) derived from abdominal portal venous phase computed tomography (CT) examinations on a novel dual-layer spectral-detector CT (SDCT). METHODS From 50 patients, SDCT data sets MonoE at 40 kiloelectron volt as well as PolyE were reconstructed and best individual window width and level values manually were assessed separately for evaluation of abdominal arteries as well as for liver lesions. Via regression analysis, optimized individual values were mathematically calculated. Subjective image quality parameters, vessel, and liver lesion diameters were measured to determine influences of different W/L settings. RESULTS Attenuation and contrast-to-noise values were significantly higher in MonoE compared with PolyE. Compared with standard settings, almost all adjusted W/L settings varied significantly and yielded higher subjective scoring. No differences were found between manually adjusted and mathematically calculated W/L settings. CONCLUSIONS PolyE and MonoE from abdominal portal venous phase SDCT examinations require appropriate W/L settings depending on reconstruction technique and assessment focus.
Collapse
|
29
|
Zhao L, Li F, Zhang Z, Zhang Z, Jiang Y, Wang X, Gu J, Li D. Assessment of an advanced virtual monoenergetic reconstruction technique in cerebral and cervical angiography with third-generation dual-source CT: Feasibility of using low-concentration contrast medium. Eur Radiol 2018; 28:4379-4388. [PMID: 29654560 DOI: 10.1007/s00330-018-5407-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2017] [Revised: 02/13/2018] [Accepted: 02/22/2018] [Indexed: 12/26/2022]
Abstract
OBJECTIVES To investigate the feasibility of low-concentration contrast media (LC-CM) in cerebral and cervical dual-energy CT angiography (DE-CTA) using an advanced monoenergetic (Mono+) reconstruction technique. METHODS Sixty-five consecutive patients prospectively selected to undergo cerebral and cervical DE-CTA were randomised into two groups: 32 patients (63.7 ± 9.7 years) in the high-concentration contrast medium (HC-CM) group with iopromide 370 and 33 patients (60.7 ± 10.8 years) in the low-concentration contrast medium (LC-CM) group with iodixanol 270. Traditional monoenergetic (Mono) and Mono+ images from 40 to 100 keV levels (at 10-keV intervals) and the standard mixed (Mixed, 120 kVp equivalent) images were reconstructed. Subjective image quality parameters included the contrast-to-noise ratio (CNR) and objective image quality parameters were evaluated and compared between the two groups. RESULTS The 40-keV Mono+ images in the LC-CM group showed comparable objective CNR (common carotid arteries: 83.7 ± 24.5 vs. 78.1 ± 23.2; internal carotid arteries: 82.2 ± 26.8 vs. 76.8 ± 24.1; middle cerebral arteries: 72.5 ± 24.6 vs. 70.6 ± 19.2; all p > 0.05) and subjective image scores (3.95 ± 0.19 vs. 3.83 ± 0.35; p > 0.05) compared with Mixed images in the HC-CM group. CONCLUSION The Mono+ reconstruction technique could reduce the concentration of iodinated CM in the diagnosis of cerebral and cervical angiography. KEY POINTS • Mono+ shows decreased noise and superior CNR compared with Mono. • The 40-keV Mono+ images show the highest CNR in the LC-CM group. • The Mono+ reconstruction technique could reduce the concentration of iodinated CM.
Collapse
Affiliation(s)
- Lu Zhao
- Department of Radiology, Tianjin Medical University General Hospital, Tianjin, 300052, China
| | - Fengtan Li
- Department of Radiology, Tianjin Medical University General Hospital, Tianjin, 300052, China
| | - Zewei Zhang
- Department of Radiology, Tianjin Medical University General Hospital, Tianjin, 300052, China
| | - Zhang Zhang
- Department of Radiology, Tianjin Medical University General Hospital, Tianjin, 300052, China
| | - Yingjian Jiang
- Department of Radiology, Tianjin Medical University General Hospital, Tianjin, 300052, China
| | - Xinyu Wang
- Department of Radiology, Tianjin Medical University General Hospital, Tianjin, 300052, China
| | - Jun Gu
- Siemens Healthineers, Beijing, 100102, China
| | - Dong Li
- Department of Radiology, Tianjin Medical University General Hospital, Tianjin, 300052, China.
| |
Collapse
|
30
|
Contrast media injection protocol optimization for dual-energy coronary CT angiography: results from a circulation phantom. Eur Radiol 2018; 28:3473-3481. [PMID: 29488083 DOI: 10.1007/s00330-018-5308-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2017] [Revised: 12/20/2017] [Accepted: 01/03/2018] [Indexed: 12/12/2022]
Abstract
OBJECTIVES To investigate the minimum iodine delivery rate (IDR) required to achieve diagnostic coronary attenuation (300 HU) with dual-energy coronary CTA. METHODS Acquisitions were performed on a circulation phantom with a third- generation dual-source CT scanner. Contrast media was injected for a fixed time whilst IDRs varied from 1.0 to 0.3 gI/s in 0.1-gI/s intervals. Noise-optimized virtual monoenergetic imaging (VMI+) reconstructions from 40 to 90 keV in 5 keV increments were generated. Contrast-to-noise ratio (CNR) and coronary HU were measured for each injection. RESULTS VMI+ from 40-70 keV reached diagnostic attenuation with at least one IDR. The minimum IDR achieving a diagnostic attenuation ranged from 0.4 gI/s at 40 keV (312.8 HU) to 1.0 gI/s at 70 keV (334.1 HU). Attenuation values reached with IDR of 1.0 gI/s were significantly higher at each keV level (p<0.001). CNR showed a near perfect correlation with the IDR (ρ≥0.962; p<0.001), the IDR of 1.0 gI/s provided the highest CNR at each keV level, achieving the highest overall value at 40 keV (54.0±3.1). CONCLUSIONS IDRs from 0.4-1.0 gI/s associated with VMI+ from 40-70 keV provide diagnostic coronary attenuation with dual-energy coronary CTA. KEY POINTS • Iodine delivery rate (IDR) is a major determinant of contrast enhancement. • Low-keV noise-optimized monoenergetic images (VMI+) maximize iodine attenuation. • Low-keV VMI+ allows for lower IDRs while maintaining adequate coronary attenuation. • Lowest IDR to reach 300 HU was 0.4 gI/s, 40 keV VMI+.
Collapse
|
31
|
Leithner D, Mahmoudi S, Wichmann JL, Martin SS, Lenga L, Albrecht MH, Booz C, Arendt CT, Beeres M, D'Angelo T, Bodelle B, Vogl TJ, Scholtz JE. Evaluation of virtual monoenergetic imaging algorithms for dual-energy carotid and intracerebral CT angiography: Effects on image quality, artefacts and diagnostic performance for the detection of stenosis. Eur J Radiol 2018; 99:111-117. [DOI: 10.1016/j.ejrad.2017.12.024] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2017] [Revised: 12/01/2017] [Accepted: 12/29/2017] [Indexed: 10/18/2022]
|
32
|
Impact of noise-optimized virtual monoenergetic dual-energy computed tomography on image quality in patients with renal cell carcinoma. Eur J Radiol 2017; 97:1-7. [DOI: 10.1016/j.ejrad.2017.10.008] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2017] [Revised: 10/01/2017] [Accepted: 10/05/2017] [Indexed: 01/14/2023]
|
33
|
D’Angelo T, Bucher AM, Lenga L, Arendt CT, Peterke JL, Caruso D, Mazziotti S, Blandino A, Ascenti G, Othman AE, Martin SS, Leithner D, Vogl TJ, Wichmann JL. Optimisation of window settings for traditional and noise-optimised virtual monoenergetic imaging in dual-energy computed tomography pulmonary angiography. Eur Radiol 2017; 28:1393-1401. [DOI: 10.1007/s00330-017-5059-6] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2017] [Revised: 08/16/2017] [Accepted: 09/05/2017] [Indexed: 12/30/2022]
|
34
|
Scholtz JE, Ghoshhajra B. Advances in cardiac CT contrast injection and acquisition protocols. Cardiovasc Diagn Ther 2017; 7:439-451. [PMID: 29255688 PMCID: PMC5716940 DOI: 10.21037/cdt.2017.06.07] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2016] [Accepted: 05/25/2017] [Indexed: 01/27/2023]
Abstract
Cardiac computed tomography (CT) imaging has become an important part of modern cardiovascular care. Coronary CT angiography (CTA) is the first choice imaging modality for non-invasive visualization of coronary artery stenosis. In addition, cardiac CT does not only provide anatomical evaluation, but also functional and valvular assessment, and myocardial perfusion evaluation. In this article we outline the factors which influence contrast enhancement, give an overview of current contrast injection and acquisition protocols, with focus on current emerging topics such as pre-transcatheter aortic valve replacement (TAVR) planning, cardiac CT for congenital heart disease (CHD) patients, and myocardial CT perfusion (CTP). Further, we point out areas where we see potential for future improvements in cardiac CT imaging based on a closer interaction between CT scanner settings and contrast injection protocols to tailor injections to patient- and exam-specific factors.
Collapse
Affiliation(s)
- Jan-Erik Scholtz
- Cardiac MR PET CT Program, Department of Radiology (Cardiovascular Imaging) and Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Brian Ghoshhajra
- Cardiac MR PET CT Program, Department of Radiology (Cardiovascular Imaging) and Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| |
Collapse
|
35
|
Dual-energy computed tomography in patients with cutaneous malignant melanoma: Comparison of noise-optimized and traditional virtual monoenergetic imaging. Eur J Radiol 2017; 95:1-8. [DOI: 10.1016/j.ejrad.2017.07.017] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2017] [Revised: 06/27/2017] [Accepted: 07/19/2017] [Indexed: 02/06/2023]
|
36
|
Cardiac Dual-Energy CT Applications and Clinical Impact. CURRENT RADIOLOGY REPORTS 2017. [DOI: 10.1007/s40134-017-0237-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
37
|
Martin SS, Pfeifer S, Wichmann JL, Albrecht MH, Leithner D, Lenga L, Scholtz JE, Vogl TJ, Bodelle B. Noise-optimized virtual monoenergetic dual-energy computed tomography: optimization of kiloelectron volt settings in patients with gastrointestinal stromal tumors. Abdom Radiol (NY) 2017; 42:718-726. [PMID: 27999889 DOI: 10.1007/s00261-016-1011-5] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
PURPOSE The aim of this study was to evaluate the impact of a noise-optimized virtual monoenergetic imaging (VMI+) reconstruction technique on quantitative and qualitative image analysis in patients with gastrointestinal stromal tumors (GISTs) at dual-energy computed tomography (DECT) of the abdomen. METHODS Forty-five DECT datasets of 21 patients (14 men; 63.7 ± 9.2 years) with GISTs were reconstructed with the standard linearly blended (M_0.6) and VMI+ and traditional virtual monoenergetic (VMI) algorithm in 10-keV increments from 40 to 100 keV. Attenuation measurements were performed in GIST lesions and abdominal metastases to calculate objective signal-to-noise (SNR) and contrast-to-noise ratios (CNR). Five-point scales were used to evaluate overall image quality, lesion delineation, image sharpness, and image noise. RESULTS Quantitative image parameters peaked at 40-keV VMI+ series (SNR 27.8 ± 13.0; CNR 26.3 ± 12.7), significantly superior to linearly blended (SNR 16.8 ± 7.3; CNR 13.6 ± 6.9) and all VMI series (all P < 0.001). Qualitative image parameters were highest for 60-keV VMI+ reconstructions regarding overall image quality and image sharpness (median 5, respectively; P ≤ 0.023). Qualitative assessment of lesion delineation peaked in 40 and 50-keV VMI+ series (median 5, respectively). Image noise was superior in 90 and 100-keV VMI and VMI+ reconstructions (all medians 5). CONCLUSIONS Low-keV VMI+ reconstructions significantly increase SNR and CNR of GISTs and improve quantitative and qualitative image quality of abdominal DECT datasets compared to traditional VMI and standard linearly blended image series.
Collapse
Affiliation(s)
- Simon S Martin
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Sophia Pfeifer
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Julian L Wichmann
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany.
| | - Moritz H Albrecht
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
- Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA
| | - Doris Leithner
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Lukas Lenga
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Jan-Erik Scholtz
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
- Cardiac MR PET CT Program, Harvard Medical School, Massachusetts General Hospital, Boston, MA, USA
| | - Thomas J Vogl
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Boris Bodelle
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| |
Collapse
|
38
|
Sandfort V, Palanisamy S, Symons R, Pourmorteza A, Ahlman MA, Rice K, Thomas T, Davies-Venn C, Krauss B, Kwan A, Pandey A, Zimmerman SL, Bluemke DA. Optimized energy of spectral CT for infarct imaging: Experimental validation with human validation. J Cardiovasc Comput Tomogr 2017; 11:171-178. [PMID: 28229910 DOI: 10.1016/j.jcct.2017.02.003] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2017] [Revised: 02/03/2017] [Accepted: 02/07/2017] [Indexed: 10/20/2022]
Abstract
OBJECTIVES Late contrast enhancement visualizes myocardial infarction, but the contrast to noise ratio (CNR) is low using conventional CT. The aim of this study was to determine if spectral CT can improve imaging of myocardial infarction. MATERIALS AND METHODS A canine model of myocardial infarction was produced in 8 animals (90-min occlusion, reperfusion). Later, imaging was performed after contrast injection using CT at 90 kVp/150 kVpSn. The following reconstructions were evaluated: Single energy 90 kVp, mixed, iodine map, multiple monoenergetic conventional and monoenergetic noise optimized reconstructions. Regions of interest were measured in infarct and remote regions to calculate contrast to noise ratio (CNR) and Bhattacharya distance (a metric of the differentiation between regions). Blinded assessment of image quality was performed. The same reconstruction methods were applied to CT scans of four patients with known infarcts. RESULTS For animal studies, the highest CNR for infarct vs. myocardium was achieved in the lowest keV (40 keV) VMo images (CNR 4.42, IQR 3.64-5.53), which was superior to 90 kVp, mixed and iodine map (p = 0.008, p = 0.002, p < 0.001, respectively). Compared to 90 kVp and iodine map, the 40 keV VMo reconstructions showed significantly higher histogram separation (p = 0.042 and p < 0.0001, respectively). The VMo reconstructions showed the highest rate of excellent quality scores. A similar pattern was seen in human studies, with CNRs for infarct maximized at the lowest keV optimized reconstruction (CNR 4.44, IQR 2.86-5.94). CONCLUSIONS Dual energy in conjunction with noise-optimized monoenergetic post-processing improves CNR of myocardial infarct delineation by approximately 20-25%.
Collapse
Affiliation(s)
- Veit Sandfort
- Radiology and Imaging Sciences - National Institutes of Health Clinical Center, Bethesda, MD, USA
| | - Srikanth Palanisamy
- Radiology and Imaging Sciences - National Institutes of Health Clinical Center, Bethesda, MD, USA
| | - Rolf Symons
- Radiology and Imaging Sciences - National Institutes of Health Clinical Center, Bethesda, MD, USA
| | - Amir Pourmorteza
- Radiology and Imaging Sciences - National Institutes of Health Clinical Center, Bethesda, MD, USA
| | - Mark A Ahlman
- Radiology and Imaging Sciences - National Institutes of Health Clinical Center, Bethesda, MD, USA
| | - Kelly Rice
- ORS Division of Veterinary Resources, National Institutes of Health, Bethesda, MD, USA
| | - Tom Thomas
- ORS Division of Veterinary Resources, National Institutes of Health, Bethesda, MD, USA
| | - Cynthia Davies-Venn
- Radiology and Imaging Sciences - National Institutes of Health Clinical Center, Bethesda, MD, USA
| | | | - Alan Kwan
- Johns Hopkins University, Baltimore, MD, USA
| | | | | | - David A Bluemke
- Radiology and Imaging Sciences - National Institutes of Health Clinical Center, Bethesda, MD, USA.
| |
Collapse
|