Yan C, Liu J, Min J, Zhou H, Gu J, Zhou G, Chen C, Yang C, Zeng M. Radiation Dose and Image quality of coronary CT angiography performed with whole-heart coverage CT scanner with 0.25s rotation time in patients with irregular heart rhythm. Heliyon 2024; 10:e25320. [PMID: 38375311 PMCID: PMC10875372 DOI: 10.1016/j.heliyon.2024.e25320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 12/25/2023] [Accepted: 01/24/2024] [Indexed: 02/21/2024] Open
Abstract
Objectives To evaluate radiation exposure, image quality, and diagnostic performance of coronary CT angiography (CCTA) using the invasive coronary angiography (ICA) as the reference standard in patients with irregular heart rhythm on a 0.25 s rotation time, 16 cm coverage, single-beat, CT scanner with AI-assisted motion correction. Methods CCTA data-sheets of 427 patients using a CT scanner with an ECG monitoring system and motion correction algorithm were collected retrospectively. All the patients were divided into two groups: regular heart rhythm (357 patients) and irregular heart rhythm (70 patients). 22 patients in irregular heart rhythm underwent ICA. Image quality and effective dose in both groups were evaluated and compared. Image quality was evaluated on 5-point scales. The diagnostic performance of CCTA in irregular heart rhythm group was compared with the results of ICA. Results The image quality in both groups was similar (4.34 ± 0.47 vs 4.37 ± 0.48, p > 0.05). No significant difference was observed in effective dose between two groups (2.7 ± 0.7 vs 2.9 ± 1.3, p > 0.05). The diagnostic accuracy was 90.91% in a patient-based analysis, 96.97% in a vessel-based analysis, and 98.61% in a segment-based analysis. In irregular heart rhythm group, gender was an important factor affecting the number of CCTA scans in a single examination and the radiation dose exposed to the patient. Conclusions For patients with irregular heart rhythm, a CT scanner with an ECG monitoring system and motion correction algorithm can not only reduce the radiation dose to the same level as patients with normal heart rhythms, but also ensure that the images with high diagnostic accuracy.
Collapse
Affiliation(s)
- Cheng Yan
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Jing Liu
- Department of Radiology, Fudan University Shanghai Cancer Center, Shanghai, 20032, China
| | - Ji Min
- Shanghai United Imaging Healthcare, Shanghai, 201800, China
| | - Heng Zhou
- University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Junying Gu
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Guofeng Zhou
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Caizhong Chen
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Chun Yang
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Mengsu Zeng
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| |
Collapse
|
2
|
Cappello IA, Pannone L, Della Rocca DG, Sorgente A, Del Monte A, Mouram S, Vetta G, Kronenberger R, Ramak R, Overeinder I, Bala G, Almorad A, Ströker E, Sieira J, La Meir M, Belsack D, Sarkozy A, Brugada P, Tanaka K, Chierchia GB, Gharaviri A, de Asmundis C. Coronary artery disease in atrial fibrillation ablation: impact on arrhythmic outcomes. Europace 2023; 25:euad328. [PMID: 38064697 PMCID: PMC10751806 DOI: 10.1093/europace/euad328] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2023] [Accepted: 10/09/2023] [Indexed: 12/18/2023] Open
Abstract
AIMS Catheter ablation (CA) is an established treatment for atrial fibrillation (AF). A computed tomography (CT) may be performed before ablation to evaluate the anatomy of pulmonary veins. The aim of this study is to investigate the prevalence of patients with coronary artery disease (CAD) detected by cardiac CT scan pre-ablation and to evaluate the impact of CAD and revascularization on outcomes after AF ablation. METHODS AND RESULTS All consecutive patients with AF diagnosis, hospitalized at Universitair Ziekenhuis Brussel, Belgium, between 2015 and 2019, were prospectively screened for enrolment in the study. Inclusion criteria were (i) AF diagnosis, (ii) first procedure of AF ablation with cryoballoon CA, and (iii) contrast CT scan performed pre-ablation. A total of 576 consecutive patients were prospectively included and analysed in this study. At CT scan, 122 patients (21.2%) were diagnosed with CAD, of whom 41 patients (7.1%) with critical CAD. At survival analysis, critical CAD at CT scan was a predictor of atrial tachyarrhythmia (AT) recurrence during the follow-up, only in Cox univariate analysis [hazard ratio (HR) = 1.79] but was not an independent predictor in Cox multivariate analysis. At Cox multivariate analysis, independent predictors of AT recurrence were as follows: persistent AF (HR = 2.93) and left atrium volume index (HR = 1.04). CONCLUSION In patients undergoing CT scan before AF ablation, critical CAD was diagnosed in 7.1% of patients. Coronary artery disease and revascularization were not independent predictors of recurrence; thus, in this patient population, AF ablation should not be denied and can be performed together with CAD treatment.
Collapse
Affiliation(s)
- Ida Anna Cappello
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Luigi Pannone
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Domenico Giovanni Della Rocca
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Antonio Sorgente
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Alvise Del Monte
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Sahar Mouram
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Giampaolo Vetta
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Rani Kronenberger
- Cardiac Surgery Department, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, Brussels, Belgium
| | - Robbert Ramak
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Ingrid Overeinder
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Gezim Bala
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Alexandre Almorad
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Erwin Ströker
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Juan Sieira
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Mark La Meir
- Cardiac Surgery Department, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, Brussels, Belgium
| | - Dries Belsack
- Department of Radiology, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, Brussels, Belgium
| | - Andrea Sarkozy
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Pedro Brugada
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Kaoru Tanaka
- Department of Radiology, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, Brussels, Belgium
| | - Gian Battista Chierchia
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Ali Gharaviri
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Carlo de Asmundis
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| |
Collapse
|
3
|
Foldyna B, Sandri M, Luecke C, Garbade J, Gohmann R, Hahn J, Fischer J, Gutberlet M, Lehmkuhl L. Quantitative coronary computed tomography angiography for the detection of cardiac allograft vasculopathy. Eur Radiol 2020; 30:4317-4326. [PMID: 32179995 PMCID: PMC7338811 DOI: 10.1007/s00330-019-06653-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Revised: 11/20/2019] [Accepted: 12/19/2019] [Indexed: 12/21/2022]
Abstract
Objectives To associate coronary wall volume and composition, derived from coronary computed tomography angiography (CTA), with cardiac allograft vasculopathy (CAV) detected on invasive coronary angiography (ICA) in heart-transplanted (HTX) patients. Methods We included consecutive adults who received ICA and coronary CTA for evaluation of CAV ≥ 10 months after HTX. In all coronary segments, we assessed lumen and wall volumes and segmental length, calculated volume-length ratio (VLR) (volumes indexed by segmental length; mm3/mm), wall burden (WB) (wall/wall + lumen volumes; %), and assessed proportions of calcified, fibrotic, fibro-fatty, and low-attenuation tissue (%) in coronary wall. We rendered independent CTA measures associated with CAV by ICA, tested their discriminatory capacity, and assessed concordance between CTA and ICA. Results Among 50 patients (84% men; 53.6 ± 11.9 years), we analyzed 632 coronary segments. Mean interval between HTX and CTA was 6.7 ± 4.7 years and between ICA and CTA 1 (0–1) day. Segmental VLR, WB, and proportion of fibrotic tissue were independently associated with CAV (OR = 1.06–1.27; p ≤ 0.002), reaching a high discriminatory capacity (combination of all three: AUC = 0.84; 95%CI, 0.75–0.90). Concordance between CTA and ICA was higher in advanced CAV (88%) compared with that in none (37%) and mild (19%) CAV. Discordance was primarily driven by a large number of segments with coronary wall changes on CTA but without luminal stenoses on ICA (177/591; 25%). Conclusion CTA-derived coronary wall VLR, WB, and the proportion of fibrotic tissue are independent markers of CAV. Combination of these three parameters may aid the detection of early CAV not detected by ICA, the current standard of care. Key Points • Coronary CTA detects CAV in HTX patients. • Coronary wall volume-length ratio, wall burden, and proportion of fibrotic tissue are independently associated with CAV. • In contrast to ICA, coronary CTA may identify the early stages of CAV. Electronic supplementary material The online version of this article (10.1007/s00330-019-06653-3) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Borek Foldyna
- Department of Interventional and Diagnostic Radiology, University of Leipzig - Heart Center, Struempellstrasse 39, 04289, Leipzig, Germany. .,Cardiovascular Imaging Research Center, Massachusetts General Hospital - Harvard Medical School, Boston, MA, USA. .,Clinic for Radiology, Cardiovascular Center Bad Neustadt, Bad Neustadt, Germany.
| | - Marcus Sandri
- Department of Cardiology, University of Leipzig - Heart Center, Leipzig, Germany
| | - Christian Luecke
- Department of Interventional and Diagnostic Radiology, University of Leipzig - Heart Center, Struempellstrasse 39, 04289, Leipzig, Germany
| | - Jens Garbade
- University Department for Cardiac Surgery, Leipzig Heart Center, Leipzig, Germany
| | - Robin Gohmann
- Department of Interventional and Diagnostic Radiology, University of Leipzig - Heart Center, Struempellstrasse 39, 04289, Leipzig, Germany
| | - Jochen Hahn
- University Department for Cardiac Surgery, Leipzig Heart Center, Leipzig, Germany
| | - Julia Fischer
- Department of Cardiology, University of Leipzig - Heart Center, Leipzig, Germany
| | - Matthias Gutberlet
- Department of Interventional and Diagnostic Radiology, University of Leipzig - Heart Center, Struempellstrasse 39, 04289, Leipzig, Germany
| | - Lukas Lehmkuhl
- Department of Interventional and Diagnostic Radiology, University of Leipzig - Heart Center, Struempellstrasse 39, 04289, Leipzig, Germany.,Clinic for Radiology, Cardiovascular Center Bad Neustadt, Bad Neustadt, Germany
| |
Collapse
|
4
|
Mushtaq S, Conte E, Melotti E, Andreini D. Coronary CT Angiography in Challenging Patients: High Heart Rate and Atrial Fibrillation. A Review. Acad Radiol 2019; 26:1544-1549. [PMID: 30745172 DOI: 10.1016/j.acra.2019.01.022] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2018] [Revised: 01/17/2019] [Accepted: 01/20/2019] [Indexed: 12/28/2022]
Abstract
Despite several strategies have been developed by different vendors to improve image quality and diagnostic accuracy of coronary CT angiography performed at high heart rate (HR) and HR variability, as in patients with atrial fibrillation (AF), some concerns and small clinical experience characterize these subsets of challenging patients. However, patients with AF have been reported to have higher risk of cardiovascular events and noninvasive evaluation of suspected coronary artery disease in this setting may be of extreme clinical interest. The goal of this review is to provide to the reader an overview on the use of cardiac CT in patients with AF and high HR and to outline the technological improvements recently introduced in the clinical field that may enable to definitively overcome the limitations of cardiac CT in this challenging scenario.
Collapse
|
5
|
Chen Y, Liu Z, Li M, Yu Y, Jia Y, Ma G, Hu Z, Wei D, Li D, He T. Reducing both radiation and contrast doses in coronary CT angiography in lean patients on a 16-cm wide-detector CT using 70 kVp and ASiR-V algorithm, in comparison with the conventional 100-kVp protocol. Eur Radiol 2018; 29:3036-3043. [PMID: 30506217 DOI: 10.1007/s00330-018-5837-9] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2018] [Revised: 09/28/2018] [Accepted: 10/17/2018] [Indexed: 01/17/2023]
Abstract
OBJECTIVE To investigate the value of prospectively ECG-triggered coronary CT angiography (CCTA) for lean patients with body mass index (BMI) ≤ 23 kg/m2 using 70 kVp and high-level volume-based adaptive statistical iterative reconstruction (ASiR-V) algorithm on a 16-cm wide-detector CT system for reducing both radiation and contrast doses in comparison with the conventional 100-kVp protocol. MATERIALS AND METHODS Thirty patients (group A) were prospectively enrolled to undergo 70-kVp CCTA on a 16-cm wide-detector CT scanner with noise index (NI) of 36 HU and at weight-dependent contrast dose rate of 16 mg I/kg/s for 9-s injection. Images were reconstructed with 80% ASiR-V. Radiation dose, contrast dose, and image quality were statistically compared with 30 patients (group B) in database with matching BMI who underwent conventional 100-kVp CCTA with NI of 25 HU, and at 25 mg I/kg/s rate for 10-s injection and reconstructed with 60% ASiR-V. RESULTS There was no significant difference in patient demographics between the two groups (all p > 0.05). The two groups also had similar mean CT values and contrast-noise ratio (CNR) and subjective image quality (all p > 0.05). However, group A with 70 kVp reduced the effective dose by 75.3% compared with group B (0.43 ± 0.20 mSv vs. 1.74 ± 1.01 mSv, p < 0.001), and required 42.4% less contrast dose than group B (22.46 ± 2.94 ml vs. 38.99 ± 5.10 ml, p < 0.001). CONCLUSIONS Prospectively ECG-triggered CCTA using 70 kVp and high-level ASiR-V on a 16-cm wide-detector CT system provides diagnostic images with substantial reduction in both radiation and contrast doses for patients with BMI ≤ 23 kg/m2 compared to the conventional 100-kVp protocol. KEY POINTS • 70-kVp CCTA produces excellent images at sub-millisievert radiation. • 70-kVp CCTA reduces both radiation and contrast doses over conventional protocol. • Achieving low-dose CCTA with combined low kVp and high-level ASIR-V.
Collapse
Affiliation(s)
- Yuhuan Chen
- Shaanxi University of Chinese Medicine, Xianyang, 712000, China
- Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang, 712000, China
| | - Zhentang Liu
- Department of Radiology, Chang'an Hospital, Xi'an, 710018, Shaanxi, China
| | | | - Yong Yu
- Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang, 712000, China
| | - Yongjun Jia
- Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang, 712000, China
| | - Guangming Ma
- Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang, 712000, China
| | - Zhijun Hu
- Department of Radiology, Chang'an Hospital, Xi'an, 710018, Shaanxi, China
| | - DongHong Wei
- Department of Radiology, Chang'an Hospital, Xi'an, 710018, Shaanxi, China
| | - Dou Li
- Department of Radiology, Chang'an Hospital, Xi'an, 710018, Shaanxi, China
| | - Taiping He
- Shaanxi University of Chinese Medicine, Xianyang, 712000, China.
- Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang, 712000, China.
| |
Collapse
|
6
|
Dai X, Yu M, Pan J, Lu Z, Shen C, Wang Y, Lu B, Zhang J. Image quality and diagnostic accuracy of coronary CT angiography derived from low-dose dynamic CT myocardial perfusion: a feasibility study with comparison to invasive coronary angiography. Eur Radiol 2018; 29:4349-4356. [DOI: 10.1007/s00330-018-5777-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2018] [Revised: 08/27/2018] [Accepted: 09/19/2018] [Indexed: 11/24/2022]
|