Koike Y, Ohira S, Kihara S, Anetai Y, Takegawa H, Nakamura S, Miyazaki M, Konishi K, Tanigawa N. Synthetic Low-Energy Monochromatic Image Generation in Single-Energy Computed Tomography System Using a Transformer-Based Deep Learning Model. JOURNAL OF IMAGING INFORMATICS IN MEDICINE 2024; 37:2688-2697. [PMID: 38637424 PMCID: PMC11522201 DOI: 10.1007/s10278-024-01111-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Revised: 03/31/2024] [Accepted: 04/03/2024] [Indexed: 04/20/2024]
Abstract
While dual-energy computed tomography (DECT) technology introduces energy-specific information in clinical practice, single-energy CT (SECT) is predominantly used, limiting the number of people who can benefit from DECT. This study proposed a novel method to generate synthetic low-energy virtual monochromatic images at 50 keV (sVMI50keV) from SECT images using a transformer-based deep learning model, SwinUNETR. Data were obtained from 85 patients who underwent head and neck radiotherapy. Among these, the model was built using data from 70 patients for whom only DECT images were available. The remaining 15 patients, for whom both DECT and SECT images were available, were used to predict from the actual SECT images. We used the SwinUNETR model to generate sVMI50keV. The image quality was evaluated, and the results were compared with those of the convolutional neural network-based model, Unet. The mean absolute errors from the true VMI50keV were 36.5 ± 4.9 and 33.0 ± 4.4 Hounsfield units for Unet and SwinUNETR, respectively. SwinUNETR yielded smaller errors in tissue attenuation values compared with those of Unet. The contrast changes in sVMI50keV generated by SwinUNETR from SECT were closer to those of DECT-derived VMI50keV than the contrast changes in Unet-generated sVMI50keV. This study demonstrated the potential of transformer-based models for generating synthetic low-energy VMIs from SECT images, thereby improving the image quality of head and neck cancer imaging. It provides a practical and feasible solution to obtain low-energy VMIs from SECT data that can benefit a large number of facilities and patients without access to DECT technology.
Collapse
Affiliation(s)
- Yuhei Koike
- Department of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
| | - Shingo Ohira
- Department of Comprehensive Radiation Oncology, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, 537-8567, Japan
| | - Sayaka Kihara
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, 537-8567, Japan
| | - Yusuke Anetai
- Department of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan
| | - Hideki Takegawa
- Department of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan
| | - Satoaki Nakamura
- Department of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, 537-8567, Japan
| | - Koji Konishi
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, 537-8567, Japan
| | - Noboru Tanigawa
- Department of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan
| |
Collapse
|
2
|
Noble DJ, Ramaesh R, Brothwell M, Elumalai T, Barrett T, Stillie A, Paterson C, Ajithkumar T. The Evolving Role of Novel Imaging Techniques for Radiotherapy Planning. Clin Oncol (R Coll Radiol) 2024; 36:514-526. [PMID: 38937188 DOI: 10.1016/j.clon.2024.05.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2024] [Revised: 05/20/2024] [Accepted: 05/30/2024] [Indexed: 06/29/2024]
Abstract
The ability to visualise cancer with imaging has been crucial to the evolution of modern radiotherapy (RT) planning and delivery. And as evolving RT technologies deliver increasingly precise treatment, the importance of accurate identification and delineation of disease assumes ever greater significance. However, innovation in imaging technology has matched that seen with RT delivery platforms, and novel imaging techniques are a focus of much research activity. How these imaging modalities may alter and improve the diagnosis and staging of cancer is an important question, but already well served by the literature. What is less clear is how novel imaging techniques may influence and improve practical and technical aspects of RT planning and delivery. In this review, current gold standard approaches to integration of imaging, and potential future applications of bleeding-edge imaging technology into RT planning pathways are explored.
Collapse
Affiliation(s)
- D J Noble
- Department of Clinical Oncology, Edinburgh Cancer Centre, Western General Hospital, Crewe Road South, Edinburgh EH4 2XU, UK; Edinburgh Cancer Research Centre, Institute of Genetics and Cancer, The University of Edinburgh, Edinburgh, UK.
| | - R Ramaesh
- Department of Radiology, Western General Hospital, Edinburgh, UK
| | - M Brothwell
- Department of Clinical Oncology, University College London Hospitals, London, UK
| | - T Elumalai
- Department of Oncology, Cambridge University Hospitals NHS Foundation Trust, Addenbrooke's Hospital, Cambridge, UK
| | - T Barrett
- Department of Radiology, Cambridge University Hospitals NHS Foundation Trust, Addenbrooke's Hospital, Cambridge, UK
| | - A Stillie
- Department of Clinical Oncology, Edinburgh Cancer Centre, Western General Hospital, Crewe Road South, Edinburgh EH4 2XU, UK
| | - C Paterson
- Beatson West of Scotland Cancer Centre, Great Western Road, Glasgow G12 0YN, UK
| | - T Ajithkumar
- Department of Oncology, Cambridge University Hospitals NHS Foundation Trust, Addenbrooke's Hospital, Cambridge, UK
| |
Collapse
|
3
|
Salazar E, Liu LP, Perkins AE, Halliburton SS, Shapira N, Litt HI, Noël PB. Impact of scatter radiation on spectral quantification performance of first- and second-generation dual-layer spectral computed tomography. J Appl Clin Med Phys 2024; 25:e14383. [PMID: 38801204 PMCID: PMC11244683 DOI: 10.1002/acm2.14383] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Revised: 04/02/2024] [Accepted: 04/13/2024] [Indexed: 05/29/2024] Open
Abstract
OBJECTIVE To assess the impact of scatter radiation on quantitative performance of first and second-generation dual-layer spectral computed tomography (DLCT) systems. METHOD A phantom with two iodine inserts (1 and 2 mg/mL) configured to intentionally introduce high scattering conditions was scanned with a first- and second-generation DLCT. Collimation widths (maximum of 4 cm for first generation and 8 cm for second generation) and radiation dose levels were varied. To evaluate the performance of both systems, the mean CT numbers of virtual monoenergetic images (MonoEs) at different energies were calculated and compared to expected values. MonoEs at 50 versus 150 keV were plotted to assess material characterization of both DLCTs. Additionally, iodine concentrations were determined, plotted, and compared against expected values. For each experimental scenario, absolute errors were reported. RESULTS An experimental setup, including a phantom design, was successfully implemented to simulate high scatter radiation imaging conditions. Both CT scanners illustrated high spectral accuracy for small collimation widths (1 and 2 cm). With increased collimation (4 cm), the second-generation DLCT outperformed the earlier DLCT system. Further, the spectral performance of the second-generation DLCT at an 8 cm collimation width was comparable to a 4 cm collimation on the first-generation DLCT. A comparison of the absolute errors between both systems at lower energy MonoEs illustrates that, for the same acquisition parameters, the second-generation DLCT generated results with decreased errors. Similarly, the maximum error in iodine quantification was less with second-generation DLCT (0.45 and 0.33 mg/mL for the first and second-generation DLCT, respectively). CONCLUSION The implementation of a two-dimensional anti-scatter grid in the second-generation DLCT improves the spectral quantification performance. In the clinical routine, this improvement may enable additional clinical benefits, for example, in lung imaging.
Collapse
Affiliation(s)
- Edgar Salazar
- Department of RadiologyUniversity of PennsylvaniaPhiladelphiaPennsylvaniaUSA
- Department of Engineering and ArchitectureUniversidad Privada BolivianaLa PazBolivia
| | - Leening P. Liu
- Department of RadiologyUniversity of PennsylvaniaPhiladelphiaPennsylvaniaUSA
| | | | | | - Nadav Shapira
- Department of RadiologyUniversity of PennsylvaniaPhiladelphiaPennsylvaniaUSA
| | - Harold I. Litt
- Department of RadiologyUniversity of PennsylvaniaPhiladelphiaPennsylvaniaUSA
| | - Peter B. Noël
- Department of RadiologyUniversity of PennsylvaniaPhiladelphiaPennsylvaniaUSA
| |
Collapse
|
4
|
Liu LP, Shapira N, Halliburton SS, Meyer S, Perkins A, Litt HI, Kauczor HU, Leiner T, Stiller W, Noël PB. Spectral performance evaluation of a second-generation spectral detector CT. J Appl Clin Med Phys 2024; 25:e14300. [PMID: 38386967 PMCID: PMC11005977 DOI: 10.1002/acm2.14300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 01/10/2024] [Accepted: 01/23/2024] [Indexed: 02/24/2024] Open
Abstract
PURPOSE The aim of this study was to characterize a second-generation wide-detector dual-layer spectral computed tomography (CT) system for material quantification accuracy, acquisition parameter and patient size dependencies, and tissue characterization capabilities. METHODS A phantom with multiple tissue-mimicking and material-specific inserts was scanned with a dual-layer spectral detector CT using different tube voltages, collimation widths, radiation dose levels, and size configurations. Accuracy of iodine density maps and virtual monoenergetic images (MonoE) were investigated. Additionally, differences between conventional and MonoE 70 keV images were calculated to evaluate acquisition parameter and patient size dependencies. To demonstrate material quantification and differentiation, liver-mimicking inserts with adipose and iron were analyzed with a two-base decomposition utilizing MonoE 50 and 150 keV, and root mean square error (RMSE) for adipose and iron content was reported. RESULTS Measured inserts exhibited quantitative accuracy across a wide range of MonoE levels. MonoE 70 keV images demonstrated reduced dependence compared to conventional images for phantom size (1 vs. 27 HU) and acquisition parameters, particularly tube voltage (4 vs. 37 HU). Iodine density quantification was successful with errors ranging from -0.58 to 0.44 mg/mL. Similarly, inserts with different amounts of adipose and iron were differentiated, and the small deviation in values within inserts corresponded to a RMSE of 3.49 ± 1.76% and 1.67 ± 0.84 mg/mL for adipose and iron content, respectively. CONCLUSION The second-generation dual-layer CT enables acquisition of quantitatively accurate spectral data without compromises from differences in patient size and acquisition parameters.
Collapse
Affiliation(s)
- Leening P. Liu
- Department of RadiologyPerelman School of MedicineUniversity of PennsylvaniaPhiladelphiaPennsylvaniaUSA
- Department of BioengineeringUniversity of PennsylvaniaPhiladelphiaPennsylvaniaUSA
| | - Nadav Shapira
- Department of RadiologyPerelman School of MedicineUniversity of PennsylvaniaPhiladelphiaPennsylvaniaUSA
| | | | - Sebastian Meyer
- Department of RadiologyPerelman School of MedicineUniversity of PennsylvaniaPhiladelphiaPennsylvaniaUSA
| | | | - Harold I. Litt
- Department of RadiologyPerelman School of MedicineUniversity of PennsylvaniaPhiladelphiaPennsylvaniaUSA
| | - Hans Ulrich Kauczor
- Diagnostic and Interventional Radiology (DIR)Heidelberg University HospitalHeidelbergGermany
| | - Tim Leiner
- Department of RadiologyMayo ClinicRochesterMinnesotaUSA
| | - Wolfram Stiller
- Diagnostic and Interventional Radiology (DIR)Heidelberg University HospitalHeidelbergGermany
| | - Peter B. Noël
- Department of RadiologyPerelman School of MedicineUniversity of PennsylvaniaPhiladelphiaPennsylvaniaUSA
| |
Collapse
|
5
|
Zheng T, Xiao Y, Yang F, Dai G, Wang F, Chen G. The value of dual-layer spectral detector CT in preoperative T staging of laryngeal and hypopharyngeal squamous cell carcinoma. Eur J Radiol 2024; 171:111287. [PMID: 38176085 DOI: 10.1016/j.ejrad.2024.111287] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 11/29/2023] [Accepted: 01/01/2024] [Indexed: 01/06/2024]
Abstract
PURPOSE To explore the optimal kiloelectron voltage (keV) of virtual monochromatic images (VMIs) of dual-layer spectral detector computed tomography (DLSCT) to display laryngeal and hypopharyngeal squamous cell carcinoma (LHSCC) and its diagnostic performance for preoperative T staging of LHSCC. METHODS A total of 67 LHSCC patients were included, and the contrast between the tumor and sternocleidomastoid muscle (SM), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image noise of 40-100 keV VMIs and conventional polyenergetic images (CIs) were evaluated. The image quality of the CI and 40-100 keV VMI was evaluated by a five-point method. The VMI with the best image quality was screened out, and the accuracy of the optimal keV VMI and CI for T staging was assessed using clinical T staging as the reference standard. RESULTS The contrast between the tumor and SM, SNR, CNR and subjective image quality scores of LHSCC on 40-50 keV VMIs were higher than those on CIs (P < 0.05); the image noises of 40-100 keV VMIs were lower than those of CIs (P < 0.05). The 40 keV VMI had the highest SNR, CNR and subjective score of image quality. The accuracy rates of the 40 keV VMI and CI for T staging of LHSCC were 0.86 and 0.63 (P < 0.001), respectively. CONCLUSION The image quality of 40-50 keV VMI is higher than that of CI, and the diagnostic accuracy of 40 keV VMI is better than that of CI, which is most suitable for preoperative T staging of LHSCC.
Collapse
Affiliation(s)
- Ting Zheng
- Department of Radiology, The Affiliated Hospital of Southwest Medical University, Luzhou 646000, Sichuan, China
| | - Yan Xiao
- Department of Radiology, The Affiliated Hospital of Southwest Medical University, Luzhou 646000, Sichuan, China; Department of Radiology, Luzhou Longmatan District People's Hospital, Luzhou 646000, Sichuan, China
| | - Fan Yang
- Department of Radiology, The Affiliated Hospital of Southwest Medical University, Luzhou 646000, Sichuan, China
| | - Guidong Dai
- Department of Radiology, The Affiliated Hospital of Southwest Medical University, Luzhou 646000, Sichuan, China
| | - Fang Wang
- Department of Radiology, The Affiliated Hospital of Southwest Medical University, Luzhou 646000, Sichuan, China
| | - Guangxiang Chen
- Department of Radiology, The Affiliated Hospital of Southwest Medical University, Luzhou 646000, Sichuan, China.
| |
Collapse
|
6
|
Wang Y, Tian W, Tian S, He L, Xia J, Zhang J. Spectral CT - a new supplementary method for preoperative assessment of pathological grades of esophageal squamous cell carcinoma. BMC Med Imaging 2023; 23:110. [PMID: 37612644 PMCID: PMC10464448 DOI: 10.1186/s12880-023-01068-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Accepted: 07/31/2023] [Indexed: 08/25/2023] Open
Abstract
BACKGROUND Spectral CT imaging parameters have been reported to be useful in the differentiation of pathological grades in different malignancies. This study aims to investigate the value of spectral CT in the quantitative assessment of esophageal squamous cell carcinoma (ESCC) with different degrees of differentiation. METHODS There were 191 patients with proven ESCC who underwent enhanced spectral CT from June 2018 to March 2020 retrospectively enrolled. These patients were divided into three groups based on pathological results: well differentiated ESCC, moderately differentiated ESCC, and poorly differentiated ESCC. Virtual monoenergetic 40 keV-equivalent image (VMI40keV), iodine concentration (IC), water concentration (WC), effective atomic number (Eff-Z), and the slope of the spectral curve(λHU) of the arterial phase (AP) and venous phase (VP) were measured or calculated. The quantitative parameters of the three groups were compared by using one-way ANOVA and pairwise comparisons were performed with LSD. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic performance of these parameters in poorly differentiated groups and non-poorly differentiated groups. RESULTS There were significant differences in VMI40keV, IC, Eff-Z, and λHU in AP and VP among the three groups (all p < 0.05) except for WC (p > 0.05). The VMI40keV, IC, Eff-Z, and λHU in the poorly differentiated group were significantly higher than those in the other groups both in AP and VP (all p < 0.05). In the ROC analysis, IC performed the best in the identification of the poorly differentiated group and non-poorly differentiated group in VP (AUC = 0.729, Sensitivity = 0.829, and Specificity = 0.569 under the threshold of 21.08 mg/ml). CONCLUSIONS Quantitative parameters of spectral CT could offer supplemental information for the preoperative differential diagnosis of ESCC with different degrees of differentiation.
Collapse
Affiliation(s)
- Yi Wang
- Department of Radiology, Taizhou People's Hospital, NO.366 Taihu Road, Yiyaogaoxin District, Taizhou, 225300, Jiangsu, China
| | - Weizhong Tian
- Department of Radiology, Taizhou People's Hospital, NO.366 Taihu Road, Yiyaogaoxin District, Taizhou, 225300, Jiangsu, China
| | - Shuangfeng Tian
- Department of Radiology, Taizhou People's Hospital, NO.366 Taihu Road, Yiyaogaoxin District, Taizhou, 225300, Jiangsu, China
| | - Liang He
- Department of Radiology, Taizhou People's Hospital, NO.366 Taihu Road, Yiyaogaoxin District, Taizhou, 225300, Jiangsu, China
| | - Jianguo Xia
- Department of Radiology, Taizhou People's Hospital, NO.366 Taihu Road, Yiyaogaoxin District, Taizhou, 225300, Jiangsu, China.
| | - Ji Zhang
- Department of Radiology, Taizhou People's Hospital, NO.366 Taihu Road, Yiyaogaoxin District, Taizhou, 225300, Jiangsu, China.
| |
Collapse
|
7
|
Mellander H, Bengtsson P, Fransson V, Ramgren B, Undrén P, Drake M, Ydström K, Lätt J, Hilal A, Wassélius J, Ullberg T. Virtual monoenergetic images by spectral detector computed tomography may improve image quality and diagnostic ability for ischemic lesions in acute ischemic stroke. Acta Radiol 2023; 64:1631-1640. [PMID: 36255120 PMCID: PMC10588276 DOI: 10.1177/02841851221130612] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Accepted: 09/08/2022] [Indexed: 11/15/2022]
Abstract
BACKGROUND Acute ischemic lesions are challenging to detect by conventional computed tomography (CT). Virtual monoenergetic images may improve detection rates by increased tissue contrast. PURPOSE To compare the ability to detect ischemic lesions of virtual monoenergetic with conventional images in patients with acute stroke. MATERIAL AND METHODS We included consecutive patients at our center that underwent brain CT in a spectral scanner for suspicion of acute stroke, onset <12 h, with or without (negative controls) a confirmed cortical ischemic lesion in the initial scan or a follow-up CT or magnetic resonance imaging. Attenuation was measured in predefined areas in ischemic gray (guided by follow-up exams), normal gray, and white matter in conventional images and retrieved in spectral diagrams for the same locations in monoenergetic series at 40-200 keV. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Visual assessment of diagnostic measures was performed by independent review by two neuroradiologists blinded to reconstruction details. RESULTS In total, 29 patients were included (January 2018 to July 2019). SNR was higher in virtual monoenergetic compared to conventional images, significantly at 60-150 keV. CNR between ischemic gray and normal white matter was higher in monoenergetic images at 40-70 keV compared to conventional images. Virtual monoenergetic images received higher scores in overall image quality. The sensitivity for diagnosing acute ischemia was 93% and 97%, respectively, for the reviewers, compared to 55% of the original report based on conventional images. CONCLUSION Virtual monoenergetic reconstructions of spectral CIs may improve image quality and diagnostic ability in stroke assessment.
Collapse
Affiliation(s)
- Helena Mellander
- Department of Neuroradiology and Odontology, Center for Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden
- Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Pär Bengtsson
- Department of Neuroradiology and Odontology, Center for Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden
- Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Veronica Fransson
- Department of Translational Medicine, Medical Radiation Physics, Lund University, Malmö, Sweden
- Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | - Birgitta Ramgren
- Department of Neuroradiology and Odontology, Center for Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden
- Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Per Undrén
- Department of Neuroradiology and Odontology, Center for Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden
- Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Mattias Drake
- Department of Neuroradiology and Odontology, Center for Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden
- Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Kristina Ydström
- Department of Clinical Sciences, Lund University, Lund, Sweden
- Department of Translational Medicine, Medical Radiation Physics, Lund University, Malmö, Sweden
| | - Jimmy Lätt
- Center for Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden
| | - Amir Hilal
- Department of Neuroradiology and Odontology, Center for Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden
- Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Johan Wassélius
- Department of Neuroradiology and Odontology, Center for Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden
- Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Teresa Ullberg
- Department of Neuroradiology and Odontology, Center for Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden
- Department of Clinical Sciences, Lund University, Lund, Sweden
| |
Collapse
|
8
|
Head and neck squamous cell carcinoma: evaluation of iodine overlay maps and low-energy virtual mono-energetic images acquired with spectral detector CT. Clin Radiol 2022; 77:e425-e433. [DOI: 10.1016/j.crad.2022.02.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2021] [Accepted: 02/16/2022] [Indexed: 12/24/2022]
|
9
|
Kruis MF. Improving radiation physics, tumor visualisation, and treatment quantification in radiotherapy with spectral or dual-energy CT. J Appl Clin Med Phys 2021; 23:e13468. [PMID: 34743405 PMCID: PMC8803285 DOI: 10.1002/acm2.13468] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Revised: 10/13/2021] [Accepted: 10/19/2021] [Indexed: 12/11/2022] Open
Abstract
Over the past decade, spectral or dual‐energy CT has gained relevancy, especially in oncological radiology. Nonetheless, its use in the radiotherapy (RT) clinic remains limited. This review article aims to give an overview of the current state of spectral CT and to explore opportunities for applications in RT. In this article, three groups of benefits of spectral CT over conventional CT in RT are recognized. Firstly, spectral CT provides more information of physical properties of the body, which can improve dose calculation. Furthermore, it improves the visibility of tumors, for a wide variety of malignancies as well as organs‐at‐risk OARs, which could reduce treatment uncertainty. And finally, spectral CT provides quantitative physiological information, which can be used to personalize and quantify treatment.
Collapse
|
10
|
Hsu CCT, Jeavon C, Fomin I, Du L, Buchan C, Watkins TW, Nae Y, Parry NM, Aviv RI. Dual-Layer Spectral CT Imaging of Upper Aerodigestive Tract Cancer: Analysis of Spectral Imaging Parameters and Impact on Tumor Staging. AJNR Am J Neuroradiol 2021; 42:1683-1689. [PMID: 34326102 DOI: 10.3174/ajnr.a7239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Accepted: 04/20/2021] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Dual-layer spectral CT is a novel technology that utilized conventional single-tube CT acquisition with a dual-layer detector for the separation of high and low-energy photons to create spectral data for material decomposition. We evaluated the spectral parameters of iodine density and Z-effective values in primary head and neck squamous cell carcinoma and determined its impact on local tumor staging. MATERIALS AND METHODS Twenty-one patients with primary head and neck squamous cell carcinoma and 15 healthy controls were retrospectively evaluated. Iodine density (milligram/milliliter) and Z-effective values were compared quantitatively between head and neck squamous cell carcinoma and normal neck mucosa. The receiver operating characteristic area under the curve determined the diagnostic performance of the spectral data for local staging. We compared conventional CT images without and with iodine density and Z-effective images to determine its impact on local tumor staging. RESULTS Primary head and neck squamous cell carcinoma showed higher mean iodine density (2.01 [SD, 0.26] mg/mL, P < .001) and Z-effective values (8.21 [SD, 0.36], P < .001). A high interobserver correlation was demonstrated for ROI measurements for both the control group (iodine density, κ = 0.71, and Z-effective values, κ = 0.78) and head and neck squamous cell carcinoma (iodine density, κ = 0.84, and Z-effective values, κ = 0.75) group. The area under the curve for iodine density and Z-effective values was 0.98 and 0.93, respectively. Optimal thresholds were identified as 1.58 mg/mL (95% CI, 1.45-1.71 mg/mL; P < .001; sensitivity = 1.0; specificity = .0.93) for iodine density and 8.08 (95% CI, 7.96-8.19; P < .001; sensitivity = 0.86; specificity = 0.93) for Z-effective values. Conventional CT with the addition of dual-layer spectral data (iodine density and Z-effective values) improved the accuracy of local tumor staging in 3 of 21 patients (14%) with head and neck squamous cell carcinoma compared with the criterion standard surgical staging/histopathology. CONCLUSIONS Dual-layer spectral iodine density and Z-effective values provided increased quantitative and qualitative differentiation between upper aerodigestive head and neck squamous cell carcinoma and normal mucosa. Increased tissue differentiation improved the local tumor staging accuracy.
Collapse
Affiliation(s)
- C C-T Hsu
- From the Division of Neuroradiology (C.C.-T.H., C.J., I.F., C.B., N.M.P.)
| | - C Jeavon
- From the Division of Neuroradiology (C.C.-T.H., C.J., I.F., C.B., N.M.P.)
| | - I Fomin
- From the Division of Neuroradiology (C.C.-T.H., C.J., I.F., C.B., N.M.P.)
| | - L Du
- Department of Medical Imaging and Division of Nuclear Medicine (L.D.), and Department of Medical Imaging, Gold Coast University Hospital, Queensland, Australia
| | - C Buchan
- From the Division of Neuroradiology (C.C.-T.H., C.J., I.F., C.B., N.M.P.)
| | - T W Watkins
- Department of Medical Imaging (T.W.W.), Princess Alexandra Hospital, Queensland, Australia
| | - Y Nae
- Philips Healthcare (Y.N.), Haifa, Israel
| | - N M Parry
- From the Division of Neuroradiology (C.C.-T.H., C.J., I.F., C.B., N.M.P.)
| | - R I Aviv
- Division of Neuroradiology (R.I.A.), Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, Ontario, Canada
| |
Collapse
|
11
|
Dual-Energy Computed Tomography for the Diagnosis of Mediastinal Lymph Node Metastasis in Lung Cancer Patients: A Preliminary Study. J Comput Assist Tomogr 2021; 45:490-494. [PMID: 34297519 DOI: 10.1097/rct.0000000000001157] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE This study explored the feasibility of dual-energy computed tomography (DECT) for the diagnosis of mediastinal lymph node (LN) metastasis in patients with lung cancer. METHODS Forty-two consecutive patients with lung cancer, who underwent DECT, were included in this retrospective study. The attenuation value (Hounsfield unit) in virtual monochromatic images and the iodine concentration in the iodine map were measured at mediastinal LNs. The slope of the spectral attenuation curve (K) and normalized iodine concentration (in thoracic aorta) were calculated. The measurement results were statistically compared using 2 independent samples t test. Receiver operating characteristic curve analysis, net reclassification improvement, and integrated discrimination improvement were used to evaluate the diagnostic performance of DECT for mediastinal LN metastasis. RESULTS A total of 74 mediastinal LNs were obtained, including 33 metastatic LNs and 41 nonmetastatic LNs. The attenuation value at the lower energy levels of virtual monochromatic images (40-90 keV), K, and normalized iodine concentration demonstrated a significant difference between metastatic LNs and nonmetastatic LNs. The attenuation value at 40 keV was the most favorable biomarker for the diagnosis of mediastinal LN metastasis (area under curve, 0.91; sensitivity, 0.94; specificity, 0.81), which showed a much better performance than the LN diameter-based evaluation method (area under curve, 0.72; sensitivity, 0.66; specificity, 0.82; net reclassification improvement, 0.359; integrated discrimination improvement, 0.330). CONCLUSIONS Dual-energy computed tomography is a promising diagnostic approach for the diagnosis of mediastinal LN metastasis in patients with lung cancer, which may help clinicians implement personalized treatment strategies.
Collapse
|
12
|
Prediction of Tumor Cellularity in Resectable PDAC from Preoperative Computed Tomography Imaging. Cancers (Basel) 2021; 13:cancers13092069. [PMID: 33922981 PMCID: PMC8123300 DOI: 10.3390/cancers13092069] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 03/17/2021] [Accepted: 04/21/2021] [Indexed: 12/19/2022] Open
Abstract
Simple Summary Pancreatic ductal adenocarcinoma (PDAC) remains a devastating disease. However, variations in tumor biology influence individual patient outcomes greatly. We previously showed a strong association between magnetic resonance imaging-based tumor cell estimates and patient survival. In this study we aimed to transfer this finding to more broadly applied computed tomography (CT) imaging for non-invasive risk stratification. We correlated in vivo CT imaging with histopathological analyses and could show a strong association between regional Hounsfield Units (HU) and tumor cellularity. In conclusion, our study suggests CT-based tumor cell estimates as a widely applicable way of non-invasive tumor cellularity characterization in PDAC. Abstract Background: PDAC remains a tumor entity with poor prognosis and a 5-year survival rate below 10%. Recent research has revealed invasive biomarkers, such as distinct molecular subtypes, predictive for therapy response and patient survival. Non-invasive prediction of individual patient outcome however remains an unresolved task. Methods: Discrete cellularity regions of PDAC resection specimen (n = 43) were analyzed by routine histopathological work up. Regional tumor cellularity and CT-derived Hounsfield Units (HU, n = 66) as well as iodine concentrations were regionally matched. One-way ANOVA and pairwise t-tests were performed to assess the relationship between different cellularity level in conventional, virtual monoenergetic 40 keV (monoE 40 keV) and iodine map reconstructions. Results: A statistically significant negative correlation between regional tumor cellularity in histopathology and CT-derived HU from corresponding image regions was identified. Radiological differentiation was best possible in monoE 40 keV CT images. However, HU values differed significantly in conventional reconstructions as well, indicating the possibility of a broad clinical application of this finding. Conclusion: In this study we establish a novel method for CT-based prediction of tumor cellularity for in-vivo tumor characterization in PDAC patients.
Collapse
|
13
|
Takumi K, Hakamada H, Nagano H, Fukukura Y, Kumagae Y, Sakai O, Yoshiura T. Usefulness of dual-layer spectral CT in follow-up examinations: diagnosing recurrent squamous cell carcinomas in the head and neck. Jpn J Radiol 2020; 39:324-332. [PMID: 33215300 DOI: 10.1007/s11604-020-01071-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Accepted: 11/01/2020] [Indexed: 12/01/2022]
Abstract
PURPOSE To evaluate the usefulness of dual-energy analyses using dual-layer spectral CT (DLSCT) for diagnosing recurrent lesions of head and neck squamous cell carcinoma (HNSCC). MATERIALS AND METHODS The study population comprised 62 patients with a history of HNSCC. Attenuation values on conventional 120-kVp images and 40-keV virtual monochromatic images (VMIs) and iodine concentration (IC) were compared between recurrent lesions and post-treatment changes or non-recurrent nodes using the Mann-Whitney U test. Receiver-operating characteristic (ROC) analysis was used to assess the ability of attenuation values and IC to diagnose recurrent lesions. RESULTS Attenuation values for 120-kVp and 40-keV images and IC of local recurrent lesions were significantly higher than those of post-treatment changes (p < 0.001), whereas recurrent nodes showed significantly lower attenuation values for both 120 kVp and 40 keV and IC than non-recurrent nodes (p < 0.001). Area under the ROC curves for 120-kVp images, 40-keV images, and IC to diagnose local recurrences were 0.912, 0.992, and 0.984, respectively, and those to diagnose recurrent nodes were 0.819, 0.922, and 0.934, respectively. CONCLUSIONS Dual-energy images using DLSCT, particularly 40-keV VMIs and IC, may help in diagnosing recurrent lesions of HNSCC.
Collapse
Affiliation(s)
- Koji Takumi
- Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima, 890-8544, Japan.
| | - Hiroto Hakamada
- Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima, 890-8544, Japan
| | - Hiroaki Nagano
- Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima, 890-8544, Japan
| | - Yoshihiko Fukukura
- Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima, 890-8544, Japan
| | - Yuichi Kumagae
- Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima, 890-8544, Japan
| | - Osamu Sakai
- Departments of Radiology, Radiation Oncology, Otolaryngology-Head and Neck Surgery, Boston Medical Center, Boston University School of Medicine, Boston, MA, 02118, USA
| | - Takashi Yoshiura
- Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima, 890-8544, Japan
| |
Collapse
|
14
|
Garnett R. A comprehensive review of dual-energy and multi-spectral computed tomography. Clin Imaging 2020; 67:160-169. [PMID: 32795784 DOI: 10.1016/j.clinimag.2020.07.030] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Revised: 06/19/2020] [Accepted: 07/27/2020] [Indexed: 01/21/2023]
Abstract
This review will provide a brief introduction to the development of the first Computed Tomography (CT) scan, from the beginnings of x-ray imaging to the first functional CT system introduced by Godfrey Houndsfield. The principles behind photon interactions and the methods by which they can be leveraged to generate dual-energy or multi-spectral CT images are discussed. The clinical applications of these methodologies are investigated, showing the immense potential for dual-energy or multi-spectral CT to change the fields of in-vivo and non-destructive imaging for quantitative analysis of tissues and materials. Lastly the current trends of research for dual-energy and multi-spectral CT are covered, showing that the majority of instrument development is focused on photon counting detectors for mutli-spectral CT and that clinical research is dominated by validation studies for the implementation of dual-energy and multi-spectral CT.
Collapse
Affiliation(s)
- Richard Garnett
- McMaster University, TAB 202, 1280 Main St. W., Hamilton, Ontario L8S 4L8, Canada.
| |
Collapse
|
15
|
Nagayama Y, Inoue T, Oda S, Tanoue S, Nakaura T, Ikeda O, Yamashita Y. Adrenal Adenomas versus Metastases: Diagnostic Performance of Dual-Energy Spectral CT Virtual Noncontrast Imaging and Iodine Maps. Radiology 2020; 296:324-332. [PMID: 32452733 DOI: 10.1148/radiol.2020192227] [Citation(s) in RCA: 61] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Background Dual-energy CT allows virtual noncontrast (VNC) attenuation and iodine density measurements from contrast material-enhanced examination, potentially enabling adrenal lesion characterization. However, data regarding diagnostic performance remain limited, and combined diagnostic values have never been investigated. Purpose To determine whether VNC attenuation, iodine density, and combination of the two allow reliable differentiation between adrenal adenomas and metastases. Materials and Methods This retrospective study included patients with adrenal lesions who underwent unenhanced and portal venous phase dual-energy CT between January 2017 and December 2018. Unenhanced, contrast-enhanced, and VNC attenuation, as well as iodine density, were measured for each lesion. Agreement between unenhanced and VNC attenuation was assessed by using Wilcoxon rank-sum test, Pearson correlation coefficient, and Bland-Altman plot. The ratio of iodine density to VNC attenuation was calculated for lesions with positive VNC attenuation. Each parameter was compared between adenomas and metastases; diagnostic performance was evaluated by using the area under the receiver operating characteristic curve (AUC) with sensitivity and specificity. Results A total of 149 patients (mean age, 65 years ± 13 [standard deviation]; 89 men; 98 patients with 104 adenomas; 51 patients with 56 metastases) were evaluated. VNC attenuation showed strong positive correlation with unenhanced attenuation (r = 0.92) but resulted in overestimates of adenoma attenuation (mean bias, +11 HU; P < .001) and was less sensitive (P = .03) in the diagnosis of adenomas compared with unenhanced attenuation (sensitivity of 79% [81 of 102] [95% confidence interval {CI}: 70%, 87%] and specificity of 95% [53 of 56] [95% CI: 85%, 99%] versus sensitivity of 85% [87 of 102] [95% CI: 77%, 92%] and specificity of 96% [54 of 56] [95% CI: 88%, 100%], with thresholds of ≤29 HU and ≤22 HU, respectively). Contrast-enhanced attenuation had no discriminatory ability (AUC, 0.54; 95% CI: 0.45, 0.62). Iodine density yielded moderate performance (sensitivity of 78% [80 of 102] [95% CI: 69%, 86%] and specificity of 71% [40 of 56] [95% CI: 58%, 83%], with a threshold of ≥1.82 mg/mL). The iodine-to-VNC ratio was higher in adenomas than in metastases (mean, 14.5 vs 4.6; P < .001), with sensitivity of 95% (97 of 102; 95% CI: 89%, 98%) and specificity of 95% (53 of 56; 95% CI: 85%, 99%), with a threshold of 6.7 or greater. Conclusion Contrast-enhanced dual-energy CT during the portal venous phase enabled accurate differentiation between adrenal adenomas and metastases by combining virtual noncontrast attenuation and iodine density. Virtual noncontrast imaging alone led to overestimates of adenoma attenuation, and iodine density alone had limited discriminatory utility. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Hindman and Megibow in this issue.
Collapse
Affiliation(s)
- Yasunori Nagayama
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Chuo-ku, Kumamoto 860-8556, Japan
| | - Taihei Inoue
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Chuo-ku, Kumamoto 860-8556, Japan
| | - Seitaro Oda
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Chuo-ku, Kumamoto 860-8556, Japan
| | - Shota Tanoue
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Chuo-ku, Kumamoto 860-8556, Japan
| | - Takeshi Nakaura
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Chuo-ku, Kumamoto 860-8556, Japan
| | - Osamu Ikeda
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Chuo-ku, Kumamoto 860-8556, Japan
| | - Yasuyuki Yamashita
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Chuo-ku, Kumamoto 860-8556, Japan
| |
Collapse
|
16
|
Hsu JC, Nieves LM, Betzer O, Sadan T, Noël PB, Popovtzer R, Cormode DP. Nanoparticle contrast agents for X-ray imaging applications. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY 2020; 12:e1642. [PMID: 32441050 DOI: 10.1002/wnan.1642] [Citation(s) in RCA: 58] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Revised: 04/13/2020] [Accepted: 04/14/2020] [Indexed: 12/12/2022]
Abstract
X-ray imaging is the most widely used diagnostic imaging method in modern medicine and several advanced forms of this technology have recently emerged. Iodinated molecules and barium sulfate suspensions are clinically approved X-ray contrast agents and are widely used. However, these existing contrast agents provide limited information, are suboptimal for new X-ray imaging techniques and are developing safety concerns. Thus, over the past 15 years, there has been a rapid growth in the development of nanoparticles as X-ray contrast agents. Nanoparticles have several desirable features such as high contrast payloads, the potential for long circulation times, and tunable physicochemical properties. Nanoparticles have also been used in a range of biomedical applications such as disease treatment, targeted imaging, and cell tracking. In this review, we discuss the principles behind X-ray contrast generation and introduce new types of X-ray imaging modalities, as well as potential elements and chemical compositions that are suitable for novel contrast agent development. We focus on the progress in nanoparticle X-ray contrast agents developed to be renally clearable, long circulating, theranostic, targeted, or for cell tracking. We feature agents that are used in conjunction with the newly developed multi-energy computed tomography and mammographic imaging technologies. Finally, we offer perspectives on current limitations and emerging research topics as well as expectations for the future development of the field. This article is categorized under: Diagnostic Tools > in vivo Nanodiagnostics and Imaging Nanotechnology Approaches to Biology > Nanoscale Systems in Biology.
Collapse
Affiliation(s)
- Jessica C Hsu
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.,Department of Bioengineering, School of Engineering and Applied Science of the University of Pennsylvania, Pennsylvania, USA
| | - Lenitza M Nieves
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.,Department of Biochemistry and Molecular Biophysics, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Oshra Betzer
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan, Israel
| | - Tamar Sadan
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan, Israel
| | - Peter B Noël
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Rachela Popovtzer
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan, Israel
| | - David P Cormode
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.,Department of Bioengineering, School of Engineering and Applied Science of the University of Pennsylvania, Pennsylvania, USA.,Department of Biochemistry and Molecular Biophysics, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
17
|
Sauter AP, Shapira N, Kopp FK, Aichele J, Bodden J, Knipfer A, Rummeny EJ, Noël PB. CTPA with a conventional CT at 100 kVp vs. a spectral-detector CT at 120 kVp: Comparison of radiation exposure, diagnostic performance and image quality. Eur J Radiol Open 2020; 7:100234. [PMID: 32420413 PMCID: PMC7215101 DOI: 10.1016/j.ejro.2020.100234] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Revised: 04/10/2020] [Accepted: 04/18/2020] [Indexed: 12/15/2022] Open
Abstract
With SD-CT, increased radiation exposure is not present. In the current study, CTDIvol was lower with SD-CT than with C-CT, even when 100 kVp was used for the latter. With SD-CT, higher levels of diagnostic performance and image quality can be achieved. SD-CT may be the system of choice due to the availability of spectral data and thus additional image information.
Purpose To compare CT pulmonary angiographies (CTPAs) as well as phantom scans obtained at 100 kVp with a conventional CT (C-CT) to virtual monochromatic images (VMI) obtained with a spectral detector CT (SD-CT) at equivalent dose levels as well as to compare the radiation exposure of both systems. Material and Methods In total, 2110 patients with suspected pulmonary embolism (PE) were examined with both systems. For each system (C-CT and SD-CT), imaging data of 30 patients with the same mean CT dose index (4.85 mGy) was used for the reader study. C-CT was performed with 100 kVp and SD-CT was performed with 120 kVp; for SD-CT, virtual monochromatic images (VMI) with 40, 60 and 70 keV were calculated. All datasets were evaluated by three blinded radiologists regarding image quality, diagnostic confidence and diagnostic performance (sensitivity, specificity). Contrast-to-noise ratio (CNR) for different iodine concentrations was evaluated in a phantom study. Results CNR was significantly higher with VMI at 40 keV compared to all other datasets. Subjective image quality as well as sensitivity and specificity showed the highest values with VMI at 60 keV and 70 keV. Hereby, a significant difference to 100 kVp (C-CT) was found for image quality. The highest sensitivity was found using VMI at 60 keV with a sensitivity of more than 97 % for all localizations of PE. For diagnostic confidence and subjective contrast, highest values were found with VMI at 40 keV. Conclusion Higher levels of diagnostic performance and image quality were achieved for CPTAs with SD-CT compared to C-CT given similar dose levels. In the clinical setting SD-CT may be the modality of choice as additional spectral information can be obtained.
Collapse
Key Words
- BMI, body mass index
- C-CT, conventional spiral CT
- CNR, contrast-to-noise ratio
- CT, computed tomography
- CTDIVOL, volume-weighted CT dose index
- CTPA, CT pulmonary angiography
- Computed tomography angiography
- DE-CT, dual-Energy CT
- DLP, dose length product
- DS-CT, dual-Source CT
- ED, effective dose
- HU, Hounsfield Units
- IQ, image quality
- PE, pulmonary embolism
- Patient safety
- Pulmonary embolism
- ROI, region of interest
- Radiation exposure
- Radiologic
- SD-CT, spectral-detector CT
- Technology
- VMI, virtual monochromatic images
- kVp, peak kilovoltage
- keV, kilo-electronvolt
Collapse
Affiliation(s)
- Andreas P Sauter
- Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Department of Diagnostic and Interventional Radiology, Munich, Germany
| | - Nadav Shapira
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, USA.,Philips Healthcare, Haifa, Israel
| | - Felix K Kopp
- Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Department of Diagnostic and Interventional Radiology, Munich, Germany
| | - Juliane Aichele
- Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Department of Diagnostic and Interventional Radiology, Munich, Germany
| | - Jannis Bodden
- Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Department of Diagnostic and Interventional Radiology, Munich, Germany
| | - Andreas Knipfer
- Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Department of Diagnostic and Interventional Radiology, Munich, Germany
| | - Ernst J Rummeny
- Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Department of Diagnostic and Interventional Radiology, Munich, Germany
| | - Peter B Noël
- Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Department of Diagnostic and Interventional Radiology, Munich, Germany.,Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, USA
| |
Collapse
|
18
|
Nagayama Y, Tanoue S, Inoue T, Oda S, Nakaura T, Utsunomiya D, Yamashita Y. Dual-layer spectral CT improves image quality of multiphasic pancreas CT in patients with pancreatic ductal adenocarcinoma. Eur Radiol 2019; 30:394-403. [DOI: 10.1007/s00330-019-06337-y] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Revised: 05/30/2019] [Accepted: 06/21/2019] [Indexed: 12/19/2022]
|