1
|
Peeters MTJ, Postma AA, van Oostenbrugge RJ, Henneman WJP, Staals J. Dual-energy CT angiography in detecting underlying causes of intracerebral hemorrhage: an observational cohort study. Neuroradiology 2025; 67:331-338. [PMID: 39453445 PMCID: PMC11893716 DOI: 10.1007/s00234-024-03473-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Accepted: 09/25/2024] [Indexed: 10/26/2024]
Abstract
BACKGROUND CT angiography (CTA) is often used to detect underlying causes of acute intracerebral hemorrhage (ICH). Dual-energy CT (DECT) is able to distinguish materials with similar attenuation but different compositions, such as hemorrhage and contrast. We aimed to evaluate the diagnostic yield of DECT angiography (DECTA), compared to conventional CTA in detecting underlying ICH causes. METHODS All non-traumatic ICH patients who underwent DECTA (both arterial as well as delayed venous phase) at our center between January 2014 and February 2020 were analyzed. Conventional CTA acquisitions were reconstructed ('merged') from DECTA data. Structural ICH causes were assessed on both reconstructed conventional CTA and DECTA. The final diagnosis was based on all available diagnostic and clinical findings during one-year follow up. RESULTS Of 206 included ICH patients, 30 (14.6%) had an underlying cause as final diagnosis. Conventional CTA showed a cause in 24 patients (11.7%), DECTA in 32 (15.5%). Both false positive and false negative findings occurred more frequently on conventional CTA. DECTA detected neoplastic ICH in all seven patients with a definite neoplastic ICH diagnosis, whereas conventional CTA only detected four of these cases. Both developmental venous anomalies (DVA) and cerebral venous sinus thrombosis (CVST) were more frequently seen on DECTA. Arteriovenous malformations and aneurysms were detected equally on both imaging modalities. CONCLUSIONS Performing DECTA at clinical presentation of ICH may be of additional diagnostic value in the early detection of underlying causes, especially neoplasms, CVST and DVAs.
Collapse
Affiliation(s)
- Michaël T J Peeters
- Department of Neurology, School for Cardiovascular Diseases Maastricht (CARIM), Maastricht University Medical Center, P. Debyelaan 25, Maastricht, 6229 HX, The Netherlands.
| | - Alida A Postma
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, Netherlands
- Mental Health and Neuroscience research institute (MHeNs), Faculty of Health, Medicine and Life Sciences, Maastricht University, Maastricht, Netherlands
| | - Robert J van Oostenbrugge
- Department of Neurology, School for Cardiovascular Diseases Maastricht (CARIM), Maastricht University Medical Center, P. Debyelaan 25, Maastricht, 6229 HX, The Netherlands
| | - Wouter J P Henneman
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, Netherlands
| | - Julie Staals
- Department of Neurology, School for Cardiovascular Diseases Maastricht (CARIM), Maastricht University Medical Center, P. Debyelaan 25, Maastricht, 6229 HX, The Netherlands
| |
Collapse
|
2
|
Rajendran K, Bruesewitz M, Swicklik J, Ferrero A, Thorne J, Yu L, McCollough C, Leng S. Task-based automatic keV selection: leveraging routine virtual monoenergetic imaging for dose reduction on clinical photon-counting detector CT . Phys Med Biol 2024; 69:10.1088/1361-6560/ad41b3. [PMID: 38648795 PMCID: PMC11108732 DOI: 10.1088/1361-6560/ad41b3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Accepted: 04/22/2024] [Indexed: 04/25/2024]
Abstract
Objective. Photon-counting detector (PCD) CT enables routine virtual-monoenergetic image (VMI) reconstruction. We evaluated the performance of an automatic VMI energy level (keV) selection tool on a clinical PCD-CT system in comparison to an automatic tube potential (kV) selection tool from an energy-integrating-detector (EID) CT system from the same manufacturer.Approach.Four torso-shaped phantoms (20-50 cm width) containing iodine (2, 5, and 10 mg cc-1) and calcium (100 mg cc-1) were scanned on PCD-CT and EID-CT. Dose optimization techniques, task-based VMI energy level and tube-potential selection on PCD-CT (CARE keV) and task-based tube potential selection on EID-CT (CARE kV), were enabled. CT numbers, image noise, and dose-normalized contrast-to-noise ratio (CNRd) were compared.Main results. PCD-CT produced task-specific VMIs at 70, 65, 60, and 55 keV for non-contrast, bone, soft tissue with contrast, and vascular settings, respectively. A 120 kV tube potential was automatically selected on PCD-CT for all scans. In comparison, EID-CT used x-ray tube potentials from 80 to 150 kV based on imaging task and phantom size. PCD-CT achieved consistent dose reduction at 9%, 21% and 39% for bone, soft tissue with contrast, and vascular tasks relative to the non-contrast task, independent of phantom size. On EID-CT, dose reduction factor for contrast tasks relative to the non-contrast task ranged from a 65% decrease (vascular task, 70 kV, 20 cm phantom) to a 21% increase (soft tissue with contrast task, 150 kV, 50 cm phantom) due to size-specific tube potential adaptation. PCD-CT CNRdwas equivalent to or higher than those of EID-CT for all tasks and phantom sizes, except for the vascular task with 20 cm phantom, where 70 kV EID-CT CNRdoutperformed 55 keV PCD-CT images.Significance. PCD-CT produced more consistent CT numbers compared to EID-CT due to standardized VMI output, which greatly benefits standardization efforts and facilitates radiation dose reduction.
Collapse
Affiliation(s)
| | | | | | - Andrea Ferrero
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Jamison Thorne
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Lifeng Yu
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | | | - Shuai Leng
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
3
|
Abu-Omar A, Murray N, Ali IT, Khosa F, Barrett S, Sheikh A, Nicolaou S, Tamburrini S, Iacobellis F, Sica G, Granata V, Saba L, Masala S, Scaglione M. Utility of Dual-Energy Computed Tomography in Clinical Conundra. Diagnostics (Basel) 2024; 14:775. [PMID: 38611688 PMCID: PMC11012177 DOI: 10.3390/diagnostics14070775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 03/25/2024] [Accepted: 03/27/2024] [Indexed: 04/14/2024] Open
Abstract
Advancing medical technology revolutionizes our ability to diagnose various disease processes. Conventional Single-Energy Computed Tomography (SECT) has multiple inherent limitations for providing definite diagnoses in certain clinical contexts. Dual-Energy Computed Tomography (DECT) has been in use since 2006 and has constantly evolved providing various applications to assist radiologists in reaching certain diagnoses SECT is rather unable to identify. DECT may also complement the role of SECT by supporting radiologists to confidently make diagnoses in certain clinically challenging scenarios. In this review article, we briefly describe the principles of X-ray attenuation. We detail principles for DECT and describe multiple systems associated with this technology. We describe various DECT techniques and algorithms including virtual monoenergetic imaging (VMI), virtual non-contrast (VNC) imaging, Iodine quantification techniques including Iodine overlay map (IOM), and two- and three-material decomposition algorithms that can be utilized to demonstrate a multitude of pathologies. Lastly, we provide our readers commentary on examples pertaining to the practical implementation of DECT's diverse techniques in the Gastrointestinal, Genitourinary, Biliary, Musculoskeletal, and Neuroradiology systems.
Collapse
Affiliation(s)
- Ahmad Abu-Omar
- Department of Emergency Radiology, University of British Columbia, Vancouver General Hospital, Vancouver, BC V5Z 1M9, Canada (I.T.A.)
| | - Nicolas Murray
- Department of Emergency Radiology, University of British Columbia, Vancouver General Hospital, Vancouver, BC V5Z 1M9, Canada (I.T.A.)
| | - Ismail T. Ali
- Department of Emergency Radiology, University of British Columbia, Vancouver General Hospital, Vancouver, BC V5Z 1M9, Canada (I.T.A.)
| | - Faisal Khosa
- Department of Emergency Radiology, University of British Columbia, Vancouver General Hospital, Vancouver, BC V5Z 1M9, Canada (I.T.A.)
| | - Sarah Barrett
- Department of Emergency Radiology, University of British Columbia, Vancouver General Hospital, Vancouver, BC V5Z 1M9, Canada (I.T.A.)
| | - Adnan Sheikh
- Department of Emergency Radiology, University of British Columbia, Vancouver General Hospital, Vancouver, BC V5Z 1M9, Canada (I.T.A.)
| | - Savvas Nicolaou
- Department of Emergency Radiology, University of British Columbia, Vancouver General Hospital, Vancouver, BC V5Z 1M9, Canada (I.T.A.)
| | - Stefania Tamburrini
- Department of Radiology, Ospedale del Mare-ASL NA1 Centro, Via Enrico Russo 11, 80147 Naples, Italy
| | - Francesca Iacobellis
- Department of General and Emergency Radiology, A. Cardarelli Hospital, Via A. Cardarelli 9, 80131 Naples, Italy;
| | - Giacomo Sica
- Department of Radiology, Monaldi Hospital, Azienda Ospedaliera dei Colli, 80131 Naples, Italy;
| | - Vincenza Granata
- Division of Radiology, Istituto Nazionale Tumori IRCCS Fondazione Pascale—IRCCS Di Napoli, 80131 Naples, Italy
| | - Luca Saba
- Medical Oncology Department, AOU Cagliari, Policlinico Di Monserrato (CA), 09042 Monserrato, Italy
| | - Salvatore Masala
- Department of Medicine, Surgery and Pharmacy, University of Sassari, Viale S. Pietro, 07100 Sassari, Italy; (S.M.)
| | - Mariano Scaglione
- Department of Medicine, Surgery and Pharmacy, University of Sassari, Viale S. Pietro, 07100 Sassari, Italy; (S.M.)
- Department of Radiology, Pineta Grande Hospital, 81030 Castel Volturno, Italy
- Department of Radiology, James Cook University Hospital, Marton Road, Middlesbrough TS4 3BW, UK
| |
Collapse
|
4
|
Srinivas-Rao S, Cao J, Marin D, Kambadakone A. Dual-Energy Computed Tomography to Photon Counting Computed Tomography: Emerging Technological Innovations. Radiol Clin North Am 2023; 61:933-944. [PMID: 37758361 DOI: 10.1016/j.rcl.2023.06.015] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/03/2023]
Abstract
Computed tomography (CT) has seen remarkable developments in the past several decades, radically transforming the role of imaging in day-to-day clinical practice. Dual-energy CT (DECT), an exciting innovation introduced in the early part of this century, has widened the scope of CT, opening new opportunities due to its ability to provide superior tissue characterization. The introduction of photon-counting CT (PCCT) heralds a paradigm shift in CT scanner technology representing another significant milestone in CT innovation. PCCT offers several advantages over DECT, such as improved spectral resolution, enhanced tissue characterization, reduced image artifacts, and improved image quality.
Collapse
Affiliation(s)
- Shravya Srinivas-Rao
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA 02114-2696, USA
| | - Jinjin Cao
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA 02114-2696, USA
| | - Daniele Marin
- Department of Radiology, Duke University Medical Center, Box 3808 Erwin Road, Durham, NC 27710, USA
| | - Avinash Kambadakone
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA 02114-2696, USA.
| |
Collapse
|
5
|
Cigarrán Sexto H, Calvo Blanco J, Fernández Suárez G. Spectral CT in Emergency. RADIOLOGIA 2023; 65 Suppl 1:S109-S119. [PMID: 37024225 DOI: 10.1016/j.rxeng.2022.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 11/09/2022] [Indexed: 04/08/2023]
Abstract
Spectral CT technology is based on the acquisition of CT images with X-ray at 2 different energy levels which makes possible to distinguish between materials with different atomic numbers using their energy-dependent attenuation, even if those materials have similar density at conventional CT. This kind of technology has gained wide application due to the innumerable uses of their post-processing techniques, including virtual non-contrast images, iodine maps, virtual mono-chromatic images or mixed images without increasing radiation dose. There are several applications of spectral CT in Emergency Radiology that help in the detection, diagnosis and management of various pathologies such as differentiate haemorrhage from the underlaying causative lesion, diagnosis of pulmonary embolisms, demarcation of abscess, characterization of renal stones or reduction of artifacts. The purpose of this review is to provide the emergency radiologist a brief description of the main indications for spectral CT.
Collapse
|
6
|
Diagnostic Effectiveness of Dual Source Dual Energy Computed Tomography for Benign and Malignant Thyroid Nodules. EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE 2022; 2022:2257304. [PMID: 36034942 PMCID: PMC9402342 DOI: 10.1155/2022/2257304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Revised: 07/08/2022] [Accepted: 07/08/2022] [Indexed: 11/25/2022]
Abstract
Objective To evaluate the diagnostic effectiveness of dual source dual energy computed tomography (DS-DECT) for benign and malignant thyroid nodules. Methods Between January 2019 and December 2021, 60 patients with surgically and pathologically verified thyroid nodules treated at our institution were recruited. DS-DECT was administered to all patients. The iodine content of lesioned and normal tissues, the normalized iodine concentration (NIC) and standardized CT values of benign and malignant nodules, the consistency of examination results and pathological findings, and diagnostic effectiveness were all investigated. Results The diagnosis accuracy was the same as that of surgical pathology, producing a 100% accuracy for the 60 patients with thyroid nodules (42 were benign and 18 were malignant). The iodine content of lesioned solid tissue differed significantly from that of normal tissue, as did the iodine content of malignant and benign nodules (P < 0.05). In the arterial phase, no significant difference was found in NIC and standardized CT values between benign and malignant nodules (P > 0.05). The optimal critical NIC for differentiating benign and malignant nodules in the venous phase was 0.74 and the standardized CT value was 0.79 HU according to the receiver operating characteristics (ROC) curve. Malignant nodules were diagnosed when the NIC was <0.74 and the standardized CT value was <0.79 HU, with AUC values of 0.89 and 0.93, respectively, where the sensitivity and specificity of the differential diagnosis of NIC were 90.48% (38/42) and 88.89% (16/18), respectively, and those of the differential diagnosis of standardized CT value were 92.86% (39/ 42) and 94.44% (17/18), respectively. The diagnosis accuracy of DS-DECT was 100%, and the diagnostic results of morphological characteristics and pathological testing were consistent. The sensitivity and specificity of the NIC values and standardized CT values in the venous phase differential diagnosis of benign and malignant nodules were compatible with the morphological differential diagnosis. Conclusion DS-DECT is highly accurate in determining the benignity and malignancy of thyroid nodules and has a strong potential for clinical promotion to allow for prompt treatment.
Collapse
|
7
|
Hamid S, Nasir MU, So A, Andrews G, Nicolaou S, Qamar SR. Clinical Applications of Dual-Energy CT. Korean J Radiol 2021; 22:970-982. [PMID: 33856133 PMCID: PMC8154785 DOI: 10.3348/kjr.2020.0996] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Revised: 11/16/2020] [Accepted: 11/22/2020] [Indexed: 01/05/2023] Open
Abstract
Dual-energy CT (DECT) provides insights into the material properties of tissues and can differentiate between tissues with similar attenuation on conventional single-energy imaging. In the conventional CT scanner, differences in the X-ray attenuation between adjacent structures are dependent on the atomic number of the materials involved, whereas in DECT, the difference in the attenuation is dependent on both the atomic number and electron density. The basic principle of DECT is to obtain two datasets with different X-ray energy levels from the same anatomic region and material decomposition based on attenuation differences at different energy levels. In this article, we discuss the clinical applications of DECT and its potential robust improvements in performance and postprocessing capabilities.
Collapse
Affiliation(s)
- Saira Hamid
- Department of Radiology, University of British Columbia Hospital, University of British Columbia, Vancouver, Canada.
| | - Muhammad Umer Nasir
- Department of Medical Imaging, Vancouver General Hospital, University of British Columbia, Vancouver, Canada
| | - Aaron So
- Department of Medical Biophyics, Schulich School of Medicine and Dentistry Western University London, Ontario, Canada
| | - Gordon Andrews
- Department of Radiology, University of British Columbia Hospital, University of British Columbia, Vancouver, Canada
| | - Savvas Nicolaou
- Department of Medical Imaging, Vancouver General Hospital, University of British Columbia, Vancouver, Canada
| | - Sadia Raheez Qamar
- Department of Medical Imaging, Sunnybrook Hospital, University of Toronto, Toronto, Canada
| |
Collapse
|
8
|
Gibney B, Redmond CE, Byrne D, Mathur S, Murray N. A Review of the Applications of Dual-Energy CT in Acute Neuroimaging. Can Assoc Radiol J 2020; 71:253-265. [PMID: 32106693 DOI: 10.1177/0846537120904347] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Dual-energy computed tomography (CT) is a promising tool with increasing availability and multiple emerging and established clinical applications in neuroradiology. With its ability to allow characterization of materials based on their differential attenuation when imaged at two different energy levels, dual-energy CT can help identify the composition of brain, neck, and spinal components. Virtual monoenergetic imaging allows a range of simulated single energy-level reconstructions to be created with postprocessing. Low-energy reconstructions can aid identification of edema, ischemia, and subtle lesions due to increased soft tissue contrast as well as increasing contrast-to-noise ratios on angiographic imaging. Higher energy reconstructions can reduce image artifact from dental amalgam, aneurysm clips and coils, spinal hardware, dense contrast, and dense bones. Differentiating iodine from hemorrhage may help guide management of patients after thrombectomy and aid diagnosis of enhancing tumors within parenchymal hemorrhages. Iodine quantification may predict hematoma expansion in aneurysmal bleeds and outcomes in traumatic brain injury. Calcium and bone subtraction can be used to distinguish hemorrhage from brain parenchymal mineralization as well as improving visualization of extra-axial lesions and vessels adjacent to dense plaque or skull. This article reviews the basics of dual-energy CT and highlights many of its clinical applications in the evaluation of acute neurological presentations.
Collapse
Affiliation(s)
- Brian Gibney
- Division of Emergency Radiology, Vancouver General Hospital, Vancouver, British Columbia, Canada
| | - Ciaran E Redmond
- Division of Emergency Radiology, Vancouver General Hospital, Vancouver, British Columbia, Canada
| | - Danielle Byrne
- Division of Neuroradiology, Vancouver General Hospital, Vancouver, British Columbia, Canada
| | - Shobhit Mathur
- Department of Medical Imaging, St Michael's Hospital, University of Toronto, Toronto, Ontario, Canada
| | - Nicolas Murray
- Division of Emergency Radiology, Vancouver General Hospital, Vancouver, British Columbia, Canada
| |
Collapse
|
9
|
Albrecht MH, Vogl TJ, Martin SS, Nance JW, Duguay TM, Wichmann JL, De Cecco CN, Varga-Szemes A, van Assen M, Tesche C, Schoepf UJ. Review of Clinical Applications for Virtual Monoenergetic Dual-Energy CT. Radiology 2019; 293:260-271. [DOI: 10.1148/radiol.2019182297] [Citation(s) in RCA: 71] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
10
|
D'Angelo T, Cicero G, Mazziotti S, Ascenti G, Albrecht MH, Martin SS, Othman AE, Vogl TJ, Wichmann JL. Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications. Br J Radiol 2019; 92:20180546. [PMID: 30919651 DOI: 10.1259/bjr.20180546] [Citation(s) in RCA: 85] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Dual energy CT (DECT) has evolved into a commonly applied imaging technique in clinical routine due to its unique post-processing opportunities for improved evaluation of all body areas. Reconstruction of virtual monoenergetic imaging (VMI) series has shown beneficial effects for both non-contrast and contrast-enhanced DECT due to the flexibility to calculate low-keV VMI reconstructions to increase contrast and iodine attenuation, or to compute high-keV VMI reconstructions to reduce beam-hardening artefacts. The goal of this review article is to explain the technical background of VMI and noise-optimized VMI+ algorithms and to give an overview of useful clinical applications of the VMI technique in DECT of various body regions.
Collapse
Affiliation(s)
- Tommaso D'Angelo
- 1 Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina , Messina , Italy.,2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| | - Giuseppe Cicero
- 1 Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina , Messina , Italy
| | - Silvio Mazziotti
- 1 Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina , Messina , Italy
| | - Giorgio Ascenti
- 1 Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina , Messina , Italy
| | - Moritz H Albrecht
- 2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| | - Simon S Martin
- 2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| | - Ahmed E Othman
- 3 Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tübingen , Tübingen , Germany
| | - Thomas J Vogl
- 2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| | - Julian L Wichmann
- 2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| |
Collapse
|