1
|
Jung JW, Shin JB, Choi HJ, Pak S, Yang H, Yoon BI. Optimal dual-energy computed tomography scan parameters to detect small-sized urinary stones and their composition. Urolithiasis 2023; 51:54. [PMID: 36933126 DOI: 10.1007/s00240-023-01419-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Accepted: 02/24/2023] [Indexed: 03/19/2023]
Abstract
To investigate the optimal scanning parameters of dual-energy computed tomography (DECT), which can accurately determine sensitivity (the detectability of urinary stones) and accuracy (the composition matching of urinary stones), and to apply them to clinical trials. Fifteen urinary stones were chemically analyzed, and their chemical compositions were considered a reference standard with which we compared the uric acid (UA) and non-UA compositions determined using DECT. The urinary stones were placed inside a bolus and scanned with a dual-source CT scanner under various selected dual-energy conditions (A to X) using various solid water phantom thicknesses. These datasets were analyzed using the Siemens syngo.via software tool (integrated into the CT system) for matching the sensitivity and accuracy assessments. This study showed that 80% of the highest sensitivity (detection of urinary stones) and 92% of the highest accuracy (composition matching of urinary stones) were achieved under condition A (a collimation beam width setting of 2 × 32 × 0.6 mm, an automatic exposure control setting of 80/sn140 peak kilovoltage, and a slice thickness of 0.5/0.5 mm) (P < 0.05). Application of the DECT energy parameters presented in the study will help identify the sensitivity and accuracy of UA and non-UA stone analysis, even in patients with small-sized urinary stones and in conditions difficult for analysis.
Collapse
Affiliation(s)
- Jin-Woo Jung
- Department of Urology, International St. Mary's Hospital, Catholic Kwandong University College of Medicine, 22711 Simgokro 100Gil 25 Seo-Gu, Incheon, South Korea
| | - Jun-Bong Shin
- Department of Radiation Oncology, Kangwon National University Hospital, Chuncheon, South Korea
| | - Hyo-Jun Choi
- Department of Diagnostic Radiology, International St. Mary's Hospital, Catholic Kwandong, Incheon, South Korea
| | | | - Hyungjin Yang
- Department of Physics, Korea University Sejong Campus, Sejong, South Korea
| | - Byung Il Yoon
- Department of Urology, International St. Mary's Hospital, Catholic Kwandong University College of Medicine, 22711 Simgokro 100Gil 25 Seo-Gu, Incheon, South Korea.
| |
Collapse
|
2
|
Steuwe A, Valentin B, Bethge OT, Ljimani A, Niegisch G, Antoch G, Aissa J. Influence of a Deep Learning Noise Reduction on the CT Values, Image Noise and Characterization of Kidney and Ureter Stones. Diagnostics (Basel) 2022; 12:diagnostics12071627. [PMID: 35885532 PMCID: PMC9317055 DOI: 10.3390/diagnostics12071627] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 06/20/2022] [Accepted: 07/01/2022] [Indexed: 12/25/2022] Open
Abstract
Deep-learning (DL) noise reduction techniques in computed tomography (CT) are expected to reduce the image noise while maintaining the clinically relevant information in reduced dose acquisitions. This study aimed to assess the size, attenuation, and objective image quality of reno-ureteric stones denoised using DL-software in comparison to traditionally reconstructed low-dose abdominal CT-images and evaluated its clinical impact. In this institutional review-board-approved retrospective study, 45 patients with renal and/or ureteral stones were included. All patients had undergone abdominal CT between August 2019 and October 2019. CT-images were reconstructed using the following three methods: filtered back-projection, iterative reconstruction, and PixelShine (DL-software) with both sharp and soft kernels. Stone size, CT attenuation, and objective image quality (signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)) were evaluated and compared using Bonferroni-corrected Friedman tests. Objective image quality was measured in six regions-of-interest. Stone size ranged between 4.4 × 3.1−4.4 × 3.2 mm (sharp kernel) and 5.1 × 3.8−5.6 × 4.2 mm (soft kernel). Mean attenuation ranged between 704−717 Hounsfield Units (HU) (soft kernel) and 915−1047 HU (sharp kernel). Differences in measured stone sizes were ≤1.3 mm. DL-processed images resulted in significantly higher CNR and SNR values (p < 0.001) by decreasing image noise significantly (p < 0.001). DL-software significantly improved objective image quality while maintaining both correct stone size and CT-attenuation values. Therefore, the clinical impact of stone assessment in denoised image data sets remains unchanged. Through the relevant noise suppression, the software additionally offers the potential to further reduce radiation exposure.
Collapse
Affiliation(s)
- Andrea Steuwe
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University Dusseldorf, D-40225 Dusseldorf, Germany; (B.V.); (O.T.B.); (A.L.); (G.A.); (J.A.)
- Correspondence: ; Tel.: +49-(0)-211-81-18897
| | - Birte Valentin
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University Dusseldorf, D-40225 Dusseldorf, Germany; (B.V.); (O.T.B.); (A.L.); (G.A.); (J.A.)
| | - Oliver T. Bethge
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University Dusseldorf, D-40225 Dusseldorf, Germany; (B.V.); (O.T.B.); (A.L.); (G.A.); (J.A.)
| | - Alexandra Ljimani
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University Dusseldorf, D-40225 Dusseldorf, Germany; (B.V.); (O.T.B.); (A.L.); (G.A.); (J.A.)
| | - Günter Niegisch
- Department of Urology, Medical Faculty, University Dusseldorf, D-40225 Dusseldorf, Germany;
| | - Gerald Antoch
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University Dusseldorf, D-40225 Dusseldorf, Germany; (B.V.); (O.T.B.); (A.L.); (G.A.); (J.A.)
| | - Joel Aissa
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University Dusseldorf, D-40225 Dusseldorf, Germany; (B.V.); (O.T.B.); (A.L.); (G.A.); (J.A.)
| |
Collapse
|
3
|
Abstract
PURPOSE OF REVIEW Radiological imaging techniques and applications are constantly advancing. This review will examine modern imaging techniques in the diagnosis of urolithiasis and applications for surgical planning. RECENT FINDINGS The diagnosis of urolithiasis may be done via plain film X-ray, ultrasound (US), or contrast tomography (CT) scan. US should be applied in the workup of flank pain in emergency rooms and may reduce unnecessary radiation exposure. Low dose and ultra-low-dose CT remain the diagnostic standard for most populations but remain underutilized. Single and dual-energy CT provide three-dimensional imaging that can predict stone-specific parameters that help clinicians predict stone passage likelihood, identify ideal management techniques, and possibly reduce complications. Machine learning has been increasingly applied to 3-D imaging to support clinicians in these prognostications and treatment selection. SUMMARY The diagnosis and management of urolithiasis are increasingly personalized. Patient and stone characteristics will support clinicians in treatment decision, surgical planning, and counseling.
Collapse
|
4
|
Niehoff JH, Carmichael AF, Woeltjen MM, Boriesosdick J, Lopez Schmidt I, Michael AE, Große Hokamp N, Piechota H, Borggrefe J, Kroeger JR. Clinical Low Dose Photon Counting CT for the Detection of Urolithiasis: Evaluation of Image Quality and Radiation Dose. Tomography 2022; 8:1666-1675. [PMID: 35894003 PMCID: PMC9326560 DOI: 10.3390/tomography8040138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 06/17/2022] [Accepted: 06/20/2022] [Indexed: 11/18/2022] Open
Abstract
The purpose of this study was the evaluation of image quality and radiation dose parameters of the novel photon counting CT (PCCT, Naeotom Alpha, Siemens Healthineers) using low-dose scan protocols for the detection of urolithiasis. Standard CT scans were used as a reference (S40, Somatom Sensation 40, Siemens Healthineers). Sixty-three patients, who underwent CT scans between August and December 2021, were retrospectively enrolled. Thirty-one patients were examined with the PCCT and 32 patients were examined with the S40. Radiation dose parameters, as well as quantitative and qualitative image parameters, were analyzed. The presence of urolithiasis, image quality, and diagnostic certainty were rated on a 5-point-scale by 3 blinded readers. Both patient groups (PCCT and S40) did not differ significantly in terms of body mass index. Radiation dose was significantly lower for examinations with the PCCT compared to the S40 (2.4 ± 1.0 mSv vs. 3.4 ± 1.0 mSv; p < 0.001). The SNR was significantly better on images acquired with the PCCT (13.3 ± 3.3 vs. 8.2 ± 1.9; p < 0.001). The image quality of the PCCT was rated significantly better (4.3 ± 0.7 vs. 2.8 ± 0.6; p < 0.001). The detection rate of kidney or ureter calculi was excellent with both CT scanners (PCCT 97.8% and S40 99%, p = 0.611). In high contrast imaging, such as the depiction of stones of the kidney and the ureter, PCCT allows a significant reduction of radiation dose, while maintaining excellent diagnostic confidence and image quality. Given this image quality with our current protocol, further adjustments towards ultra-low-dose CT scans appear feasible.
Collapse
Affiliation(s)
- Julius Henning Niehoff
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 44801 Bochum, Germany; (M.M.W.); (J.B.); (I.L.S.); (A.E.M.); (J.B.); (J.R.K.)
- Correspondence: ; Tel.: +49-571-790-4601
| | - Alexandra Fiona Carmichael
- Department of Urology, Johannes Wesling University Hospital, Ruhr University Bochum, 44801 Bochum, Germany; (A.F.C.); (H.P.)
| | - Matthias Michael Woeltjen
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 44801 Bochum, Germany; (M.M.W.); (J.B.); (I.L.S.); (A.E.M.); (J.B.); (J.R.K.)
| | - Jan Boriesosdick
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 44801 Bochum, Germany; (M.M.W.); (J.B.); (I.L.S.); (A.E.M.); (J.B.); (J.R.K.)
| | - Ingo Lopez Schmidt
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 44801 Bochum, Germany; (M.M.W.); (J.B.); (I.L.S.); (A.E.M.); (J.B.); (J.R.K.)
| | - Arwed Elias Michael
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 44801 Bochum, Germany; (M.M.W.); (J.B.); (I.L.S.); (A.E.M.); (J.B.); (J.R.K.)
| | - Nils Große Hokamp
- Faculty of Medicine and University Hospital Cologne, Institute for Diagnostic and Interventional Radiology, University of Cologne, 50937 Cologne, Germany;
| | - Hansjuergen Piechota
- Department of Urology, Johannes Wesling University Hospital, Ruhr University Bochum, 44801 Bochum, Germany; (A.F.C.); (H.P.)
| | - Jan Borggrefe
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 44801 Bochum, Germany; (M.M.W.); (J.B.); (I.L.S.); (A.E.M.); (J.B.); (J.R.K.)
| | - Jan Robert Kroeger
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 44801 Bochum, Germany; (M.M.W.); (J.B.); (I.L.S.); (A.E.M.); (J.B.); (J.R.K.)
| |
Collapse
|
5
|
Ringl H, Apfaltrer P. Comparison of Four Dual-Energy CT Scanner Technologies for Determining Renal Stone Composition Using a Phantom Approach. Radiology 2022; 304:590-592. [PMID: 35638932 DOI: 10.1148/radiol.220728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Helmut Ringl
- From the Department of Radiology, Klinik Donaustadt, Langobardenstrasse 122, 1220 Vienna, Austria (H.R.); Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria (H.R.); and Division of General Radiology, Department of Radiology, Medical University of Graz, Graz, Austria (P.A.)
| | - Paul Apfaltrer
- From the Department of Radiology, Klinik Donaustadt, Langobardenstrasse 122, 1220 Vienna, Austria (H.R.); Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria (H.R.); and Division of General Radiology, Department of Radiology, Medical University of Graz, Graz, Austria (P.A.)
| |
Collapse
|
6
|
Gassenmaier S, Winkelmann MT, Magnus JP, Brendlin AS, Walter SS, Afat S, Artzner C, Nikolaou K, Bongers MN. Low-Dose CT for Renal Calculi Detection Using Spectral Shaping of High Tube Voltage. ROFO-FORTSCHR RONTG 2022; 194:1012-1019. [PMID: 35272363 DOI: 10.1055/a-1752-0472] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
PURPOSE To investigate reduction of radiation exposure in unenhanced CT in suspicion of renal calculi using a tin-filtered high tube voltage protocol compared to a standard low-dose protocol without spectral shaping. MATERIALS AND METHODS A phantom study using 7 human renal calculi was performed to test both protocols. 120 consecutive unenhanced CT examinations performed due to suspicion of renal calculi were included in this retrospective, monocentric study. 60 examinations were included with the standard-dose protocol (SP) (100 kV/130 mAs), whereas another 60 studies were included using a low-dose protocol (LD) applying spectral shaping with tin filtration of high tube voltages (Sn150 kV/80 mAs). Image quality was assessed by two radiologists in consensus blinded to technical parameters using an equidistant Likert scale ranging from 1-5 with 5 being the highest score. Quantitative image quality was assessed using regions of interest in abdominal organs, muscles, and adipose tissue to analyze image noise and signal-to-noise ratios (SNR). Commercially available dosimetry software was used to determine and compare effective dose (ED) and size-specific dose estimates (SSDEmean). RESULTS All seven renal calculi of the phantom could be detected with both protocols. There was no difference regarding calcluli size between the two protocols except for the smallest one. The smallest concretion measured 1.5 mm in LD and 1.0 mm in SP (ground truth 1.5 mm). CTDIvol was 3.36 mGy in LD (DLP: 119.3 mGycm) and 8.27 mGy in SP (DLP: 293.6 mGycm). The mean patient age in SP was 47 ± 17 years and in LD 49 ± 13 years. Ureterolithiasis was found in 33 cases in SP and 32 cases in LD. The median concretion size was 3 mm in SP and 4 mm in LD. The median ED in LD was 1.3 mSv (interquartile range (IQR) 0.3 mSv) compared to 2.3 mSv (IQR 0.9 mSv) in SP (p < 0.001). The SSDEmean of LD was also significantly lower compared to SP with 2.4 mGy (IQR 0.4 mGy) vs. 4.8 mGy (IQR 2.3 mGy) (p < 0.001). The SNR was significantly lower in LD compared to SP (p < 0.001). However, there was no significant difference between SP and LD regarding the qualitative assessment of image quality with a median of 4 (IQR 1) for both groups (p = 0.648). CONCLUSION Tin-filtered unenhanced abdominal CT for the detection of renal calculi using high tube voltages leads to a significant reduction of radiation exposure and yields high diagnostic image quality without a significant difference compared to the institution's standard of care low-dose protocol without tin filtration. KEY POINTS · Tin-filtered CT for the detection of renal calculi significantly reduces radiation dose.. · The application of tin filtration provides comparable diagnostic image quality to that of SP protocols.. · An increase in image noise does not hamper diagnostic image quality.. CITATION FORMAT · Gassenmaier S, Winkelmann MT, Magnus J et al. Low-Dose CT for Renal Calculi Detection Using Spectral Shaping of High Tube Voltage. Fortschr Röntgenstr 2022; DOI: 10.1055/a-1752-0472.
Collapse
Affiliation(s)
- Sebastian Gassenmaier
- Department of Diagnostic and Interventional Radiology, Eberhard Karls Universität Tübingen, Germany
| | - Moritz T Winkelmann
- Department of Diagnostic and Interventional Radiology, Eberhard Karls Universität Tübingen, Germany
| | - Jan-Philipp Magnus
- Department of Diagnostic and Interventional Radiology, Eberhard Karls Universität Tübingen, Germany
| | - Andreas Stefan Brendlin
- Department of Diagnostic and Interventional Radiology, Eberhard Karls Universität Tübingen, Germany
| | - Sven S Walter
- Department of Diagnostic and Interventional Radiology, Eberhard Karls Universität Tübingen, Germany.,Department of Radiology, Division of Musculoskeletal Radiology, NYU Grossman School of Medicine, New York
| | - Saif Afat
- Department of Diagnostic and Interventional Radiology, Eberhard Karls Universität Tübingen, Germany
| | - Christoph Artzner
- Department of Diagnostic and Interventional Radiology, Eberhard Karls Universität Tübingen, Germany
| | - Konstantin Nikolaou
- Department of Diagnostic and Interventional Radiology, Eberhard Karls Universität Tübingen, Germany
| | - Malte Niklas Bongers
- Department of Diagnostic and Interventional Radiology, Eberhard Karls Universität Tübingen, Germany
| |
Collapse
|
7
|
Low-dose dual-energy CT for stone characterization: a systematic comparison of two generations of split-filter single-source and dual-source dual-energy CT. Abdom Radiol (NY) 2021; 46:2079-2089. [PMID: 33159558 DOI: 10.1007/s00261-020-02852-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2020] [Revised: 10/28/2020] [Accepted: 10/30/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE To compare noise texture and accuracy to differentiate uric acid from non-uric acid urinary stones among four different single-source and dual-source DECT approaches in an ex vivo phantom study. METHODS Thirty-two urinary stones embedded in gelatin were mounted on a Styrofoam disk and placed into a water-filled phantom. The phantom was imaged using four different DECT approaches: (A) dual-source DECT (DS-DE); (B) 1st generation split-filter single-source DECT (SF1-TB); (C) 2nd generation split-filter single-source DECT (SF2-TB) and (D) 2nd generation split-filter single-source DECT using serial acquisitions (SF2-TS). Two different radiation doses (3 mGy and 6 mGy) were used. Noise texture was compared by assessing the average spatial frequency (fav) of the normalized noise power spectrum (nNPS). ROC curves for stone classification were computed and the accuracy for different dual-energy ratio cutoffs was derived. RESULTS NNPS demonstrated comparable noise texture among A, C, and D (fav-range 0.18-0.19) but finer noise texture for B (fav = 0.27). Stone classification showed an accuracy of 96.9%, 96.9%, 93.8%, 93.8% for A, B, C, D for low-dose, respectively, and 100%, 96.9%, 96.9%, 100% for routine dose. The vendor-specified cutoff for the dual-energy ratio was optimal except for the low-dose scan in D for which the accuracy was improved from 93.8 to 100% using an optimized cutoff. CONCLUSION Accuracy to differentiate uric acid from non-uric acid stones was high among four single-source and dual-source DECT approaches for low- and routine dose DECT scans. Noise texture differed only slightly for the first-generation split-filter approach.
Collapse
|
8
|
Single-energy CT predicts uric acid stones with accuracy comparable to dual-energy CT-prospective validation of a quantitative method. Eur Radiol 2021; 31:5980-5989. [PMID: 33635394 PMCID: PMC8270827 DOI: 10.1007/s00330-021-07713-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Revised: 12/10/2020] [Accepted: 01/21/2021] [Indexed: 12/26/2022]
Abstract
OBJECTIVES To prospectively validate three quantitative single-energy CT (SE-CT) methods for classifying uric acid (UA) and non-uric acid (non-UA) stones. METHODS Between September 2018 and September 2019, 116 study participants were prospectively included in the study if they had at least one 3-20-mm urinary stone on an initial urinary tract SE-CT scan. An additional dual-energy CT (DE-CT) scan was performed, limited to the stone of interest. Additionally, to include a sufficient number of UA stones, eight participants with confirmed UA stone on DE-CT were retrospectively included. The SE-CT stone features used in the prediction models were (1) maximum attenuation (maxHU) and (2) the peak point Laplacian (ppLapl) calculated at the position in the stone with maxHU. Two prediction models were previously published methods (ppLapl-maxHU and maxHU) and the third was derived from the previous results based on the k-nearest neighbors (kNN) algorithm (kNN-ppLapl-maxHU). The three methods were evaluated on this new independent stone dataset. The reference standard was the CT vendor's DE-CT application for kidney stones. RESULTS Altogether 124 participants (59 ± 14 years, 91 men) with 106 non-UA and 37 UA stones were evaluated. For classification of UA and non-UA stones, the sensitivity, specificity, and accuracy were 100% (37/37), 97% (103/106), and 98% (140/143), respectively, for kNN-ppLapl-maxHU; 95% (35/37), 98% (104/106), and 97% (139/143) for ppLapl-maxHU; and 92% (34/37), 94% (100/106), and 94% (134/143) for maxHU. CONCLUSION A quantitative SE-CT method (kNN-ppLapl-maxHU) can classify UA stones with accuracy comparable to DE-CT. KEY POINTS • Single-energy CT is the first-line diagnostic tool for suspected renal colic. • A single-energy CT method based on the internal urinary stone attenuation distribution can classify urinary stones into uric acid and non-uric acid stones with high accuracy. • This immensely increases the availability of in vivo stone analysis.
Collapse
|
9
|
Abstract
PURPOSE OF REVIEW Conventional CT imaging is an excellent tool for the diagnosis of nephrolithiasis however is limited in its ability to detect stone composition. Dual-energy CT (DECT) scans have demonstrated promise in overcoming this limitation. We review the current utility of DECT in nephrolithiasis. RECENT FINDINGS DECT is superior to conventional CT in differentiating uric acid stones from non-uric acid stones, with numerous studies reporting sensitivities and specificities approaching > 95%. Dose reduction protocols incorporating low-dose CT scans are commonly used, providing significantly lower effective radiation doses compared to conventional CT. DECT remains an effective diagnostic tool in patients with large body habitus. DECT can accurately detect uric acid stones, which can help guide which stones may be suitable to medical dissolution. Further studies evaluating the effectiveness of DECT in guiding management of patients with nephrolithiasis can help to promote its widespread use.
Collapse
|