Jordan JF, Dietlein TS, Dinslage S, Lüke C, Konen W, Krieglstein GK. Cyclodialysis ab interno as a surgical approach to intractable glaucoma.
Graefes Arch Clin Exp Ophthalmol 2007;
245:1071-6. [PMID:
17219126 DOI:
10.1007/s00417-006-0400-9]
[Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2006] [Revised: 05/23/2006] [Accepted: 06/25/2006] [Indexed: 10/23/2022] Open
Abstract
PURPOSE
In glaucoma filtration surgery, the problem of subconjunctival scarring has still not been satisfactorily solved. Suprachoroidal drainage of aqueous humour offers a promising, alternative option for intractable glaucoma. We here present a clinical study on the surgical approach of gonioscopic cyclodialysis ab interno.
PATIENTS AND METHODS
Twenty-eight eyes of 20 patients with intractable glaucoma were included in this prospective, consecutive, case-control study. The eyes had had a mean of 4.4 +/- 2.4 previous antiglaucomatous interventions. Baseline intraocular pressure (IOP) was 34.3 +/- 10.5 mmHg despite maximum therapy. Under gonioscopic control, cyclodialysis ab interno was performed over two clock times to gain access to the suprachoroidal space. No additional trabecular meshwork surgery was performed. Success was defined as a lowering of IOP to below 21 mmHg without the need for further medication or intervention.
RESULTS
Mean postoperative IOP was 14.6 +/- 12.4 mmHg. Mean follow-up (FU) for all eyes was 121.8 days. After a mean of 60 days, 21 eyes (75%) needed further surgical intervention. Qualified success was seen in four eyes (14.3%), with a mean FU of 383.6 days. Three eyes (10.7%) showed absolute success after a mean FU period of 202.7 days. In our series, we obtained the best results for phakic eyes, followed by pseudophakic and aphakic eyes.
CONCLUSION
The results of this study do not provide convincing evidence of the functional efficacy of cyclodialysis ab interno. Nevertheless, the technique is easy to perform and offers safe and atraumatic access to the resorptive capability of the choroid. Conjunctival manipulation is avoided. Contrary to reports in the current literature, in our series, the best results were obtained for phakic eyes, though the small number of eyes included does not allow reliable statistics. Further studies will need to focus on the use of different space-retaining substances or a widening of the cyclodialysis cleft to improve surgical outcome.
Collapse