1
|
Shanmugavel A, Rene ER, Balakrishnan SP, Krishnakumar N, Jose SP. Heavy metal ion sensing strategies using fluorophores for environmental remediation. ENVIRONMENTAL RESEARCH 2024; 260:119544. [PMID: 38969312 DOI: 10.1016/j.envres.2024.119544] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 05/27/2024] [Accepted: 07/01/2024] [Indexed: 07/07/2024]
Abstract
The main aim of this review is to provide a holistic summary of the latest advances within the research area focusing on the detection of heavy metal ion pollution, particularly the sensing strategies. The review explores various heavy metal ion detection approaches, encompassing spectrometry, electrochemical methods, and optical techniques. Numerous initiatives have been undertaken in recent times in response to the increasing demand for fast, sensitive, and selective sensors. Notably, fluorescent sensors have acquired prominence owing to the numerous advantages such as good specificity, reversibility, and sensitivity. Further, this review also explores the advantages of various nanomaterials employed in sensing heavy metal ions. In this regard, exclusive emphasis is placed on fluorescent nanomaterials based on organic dyes, quantum dots, and fluorescent aptasensors for metal ion removal from aqueous systems, and to identify the fate of heavy metal ions in the natural environment.
Collapse
Affiliation(s)
- Abinaya Shanmugavel
- School of Physics, Madurai Kamaraj University, Madurai, 625021, Tamil Nadu, India
| | - Eldon R Rene
- Department of Water Supply, Sanitation and Environmental Engineering, IHE Delft Institute for Water Education, Westvest 7, 2601DA, Delft, the Netherlands
| | | | | | - Sujin P Jose
- School of Physics, Madurai Kamaraj University, Madurai, 625021, Tamil Nadu, India.
| |
Collapse
|
2
|
Rezanejade Bardajee G, Rahimi Chahrogh A, Monfared A. Fabrication of Glucose Fluorescent Aptasensor Based on CdTe Quantum Dots. J Fluoresc 2024:10.1007/s10895-024-03885-5. [PMID: 39167342 DOI: 10.1007/s10895-024-03885-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2024] [Accepted: 07/29/2024] [Indexed: 08/23/2024]
Abstract
Diabetes is a chronic metabolic disease characterized by high blood glucose (or blood sugar) levels, which harms the heart, blood vessels, eyes, kidneys, and nerves over time. So, it is crucial to regularly control glucose concentration in biological fluids to check its targets, reduce unpleasant symptoms of high and low blood sugar, and avoid long-term diabetes complications. This study developed a simple, rapid, sensitive, and cost-effective fluorescence system for glucose determination. The fluorescent Aptasensor was fabricated using cadmium telluride quantum dots (CdTe QDs) modified with thioglycolic acid and functionalized with thiol-glucose-aptamer through ligand exchange. The thiol-glucose-aptamer interacted directly with CdTe QDs, increasing fluorescence intensity. However, it decreased when the target molecules of glucose were introduced. The structural and morphological characteristics of the Aptasensor were confirmed by various analytical methods such as UV-visible spectroscopy, Fourier-transform infrared spectroscopy (FT-IR), field emission scanning electron microscopy (FESEM), energy dispersive x-ray spectroscopy (EDX), transmission electron microscopy (TEM), atomic force microscopy (AFM), and dynamic light scattering (DLS). According to the typical Stern-Volmer equation, the relationship between fluorescent quenching and target concentration was linear with a detection limit (LOD) of 0.13 ± 1.95 × 10-11 mol L-1 and a relative standard deviation (RSD) of 1.05%. The Aptasensor demonstrated high specificity towards the target and stability over 28 days. Furthermore, it detected glucose in human serum and urine with a recovery rate of up to 99.74%. The results indicate that the fluorescent Aptasensor could be valuable in developing robust sensing technology for low-concentrated analytes.
Collapse
Affiliation(s)
- Ghasem Rezanejade Bardajee
- Department of Polymer and Materials Chemistry, Faculty of Chemistry and Petroleum Sciences, Shahid Beheshti University, Tehran, 19839-63113, Iran.
| | | | - Aazam Monfared
- Department of Chemistry, Payame Noor University, Tehran, 19395-3697, Iran
| |
Collapse
|
3
|
Ultrasensitive and rapid detection of methamphetamine in forensic biological fluids using fluorescent apta-nanobiosensors based on CdTe quantum dots. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/13/2023]
|
4
|
Hakimi F, Khoshkam M, Sadighian S, Ramazani A. A facile and high-sensitive bio-sensing of the V617F mutation in JAK2 gene by GSH-CdTe-QDs FRET-based sensor. Heliyon 2022; 8:e12545. [PMID: 36619431 PMCID: PMC9813721 DOI: 10.1016/j.heliyon.2022.e12545] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2022] [Revised: 11/07/2022] [Accepted: 12/14/2022] [Indexed: 12/24/2022] Open
Abstract
This study aimed to directly detect the V617F point mutation of the Janus kinase 2 (JAK2) gene in the target DNA using a FRET-based biosensor. The water-soluble GSH-CdTe-QDs were synthesized by a one-step process, then GSH-QD conjugated to the termini amino-modified oligonucleotides target via carboxylic groups on the QD surface. The prepared QDs-DNA biosensor was applied in the quantitative and rapid detection of V617F mutation with a detection limit of 3 × 10-9 mol L-1 based on the FRET mechanism. In other words, detecting the V617F mutation by bio-sensing technology would be much simpler, cheaper, time-saving, highly sensitive, and more convenient than molecular diagnostic tools. Furthermore, the nano-biosensor was applied to detect the V617F mutation in clinical samples compared to the common ARMS-PCR (Amplification Refractory Mutation System-Polymerase Chain Reaction) standard method. The results revealed that the GSH-capped biosensors would be effective for V617F mutation detection in samples distinguished with satisfactory analytical outcomes. Therefore, the designed fluorescence nanoprobe is suitable for the specific detection of V617F mutation of the JAK2 gene in clinical samples.
Collapse
Affiliation(s)
- Fatemeh Hakimi
- Department of Pharmaceutical Biomaterials, School of Pharmacy, Zanjan University of Medical Sciences, Zanjan, Iran
| | - Maryam Khoshkam
- Chemistry Group, Faculty of Basic Sciences, University of Mohaghegh Ardabili, Ardabil, Iran
| | - Somayeh Sadighian
- Department of Pharmaceutical Biomaterials, School of Pharmacy, Zanjan University of Medical Sciences, Zanjan, Iran,Cancer Gene Therapy Research Center, Zanjan University of Medical Sciences, Zanjan, Iran
| | - Ali Ramazani
- Cancer Gene Therapy Research Center, Zanjan University of Medical Sciences, Zanjan, Iran,Department of Pharmaceutical Biotechnology, School of Pharmacy, Zanjan University of Medical Sciences, Zanjan, Iran,Corresponding author.
| |
Collapse
|
5
|
Bardajee GR, Zamani M, Mahmoodian H, Elmizadeh H, Yari H, Jouyandeh L, Shirkavand R, Sharifi M. Capability of novel fluorescence DNA-conjugated CdTe/ZnS quantum dots nanoprobe for COVID-19 sensing. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2022; 269:120702. [PMID: 34922287 PMCID: PMC8656256 DOI: 10.1016/j.saa.2021.120702] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2021] [Revised: 11/13/2021] [Accepted: 11/30/2021] [Indexed: 05/20/2023]
Abstract
Urgent identification of COVID-19 in infected patients is highly important nowadays. Förster or fluorescence resonance energy transfer (FRET) is a powerful and sensitive method for nanosensing applications, and quantum dots are essential materials in FRET-based nanosensors. The QDs are conjugated to DNA or RNA and used in many applications. Therefore, in the present study, novel fluorescence DNA-conjugated CdTe/ZnS quantum dots nanoprobe designed for detection of Covid-19 after extracting their RNA from saliva of hesitant people. For achieving this purpose, the water-soluble CdTe/ZnS QDs-DNA prepared via replacing the thioglycolic acid (TGA) on the surface of QDs with capture DNA (thiolated DNA) throw a ligand-exchange method. Subsequently, by adding the different concentrations of complementary (target DNA) in a mixture of quencher DNA (BHQ2-labeled DNA) and the QDs-DNA conjugates at different conditions, sandwiched hybrids were formed. The results showed that the fluorescence intensity was decreased with increasing the concentration of target DNA (as a positive control). The linear equation and regression (Y = 40.302 X + 1 and R2 = 0.98) were obtained by using the Stern-Volmer relationship. The Limit of detection (LOD) was determined 0.000823 µM. The achieved results well confirm the outcomes of the RT-PCR method in real samples.
Collapse
Affiliation(s)
| | - Mohammadreza Zamani
- Department of Plant Biotechnology, National Institute for Genetic Engineering and Biotechnology (NIGEB), P.O. Box 14155-6343, Tehran, Iran
| | - Hossein Mahmoodian
- Department of Chemistry, Payame Noor University, P.O. Box 19395-3697, Tehran, Iran
| | - Hamideh Elmizadeh
- Legal Medicine Research Center, Legal Medicine Organization, Tehran, Iran
| | - Hadi Yari
- Medical Biotechnology Department, National Institute of Genetics Engineering and Biotechnology (NIGEB), Tehran, Iran
| | - Lavin Jouyandeh
- Department of Chemistry, Payame Noor University, P.O. Box 19395-3697, Tehran, Iran
| | - Razieh Shirkavand
- Department of Chemistry, Payame Noor University, P.O. Box 19395-3697, Tehran, Iran
| | - Mahdieh Sharifi
- Department of Chemistry, Payame Noor University, P.O. Box 19395-3697, Tehran, Iran
| |
Collapse
|
6
|
Biranje A, Azmi N, Tiwari A, Chaskar A. Quantum Dots Based Fluorescent Probe for the Selective Detection of Heavy Metal Ions. J Fluoresc 2021; 31:1241-1250. [PMID: 34181146 DOI: 10.1007/s10895-021-02755-8] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Accepted: 05/20/2021] [Indexed: 11/27/2022]
Abstract
Heavy metal ions are one of the primary causes of environmental pollution. A marshal effect of heavy metal ions is a paramount ultimatum to humans, aquatic animals and other organisms present in nature. Multitude arrays of materials have been proclaimed for sensing of heavy metal ions and also many methodologies are applied for heavy metal ion sensing. Due to their toxicity and non-biodegradability, it is required to be perceived immediately prior to its manifestation of harmful effects. Quantum Dots (QDs) are zero-dimensional nanomaterial particles and owing to their distinctive optical and electronic properties, they are utilized as nanosensors. QDs have enriched fluorescence properties which includes broad excitation spectrum, narrow emission spectrum and photostability. QDs offer eclectic and sensitive detection of heavy metal ions due to presence of discrete capping agents and different functional groups present on the surface of the QDs. These capping layers and functional groups attune the sensing capability of the QDs, which leverages the interactions of QDs with various analytes by different mechanisms. This review, comprising of papers from 2011 to 2020,focuses on heavy metal ions sensing potential of various quantum dots and its applicability as a nanosensor for on field heavy metal ions detection in water. Quantum Dots (QDs) based Heavy Metal Detection.
Collapse
Affiliation(s)
- Akshaya Biranje
- National Centre for Nanoscience and Nanotechnology, University of Mumbai, Vidyanagari, Kalina, Santacruz (East), Mumbai, 400098, India
| | - Namrah Azmi
- National Centre for Nanoscience and Nanotechnology, University of Mumbai, Vidyanagari, Kalina, Santacruz (East), Mumbai, 400098, India
| | - Abhishekh Tiwari
- National Centre for Nanoscience and Nanotechnology, University of Mumbai, Vidyanagari, Kalina, Santacruz (East), Mumbai, 400098, India.
| | - Atul Chaskar
- National Centre for Nanoscience and Nanotechnology, University of Mumbai, Vidyanagari, Kalina, Santacruz (East), Mumbai, 400098, India.
| |
Collapse
|
7
|
Bardajee GR, Zamani M, Sharifi M. Efficient and Versatile Application of Fluorescence DNA-Conjugated CdTe Quantum Dots Nanoprobe for Detection of a Specific Target DNA of SARS Cov-2 Virus. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2021; 37:10223-10232. [PMID: 34379978 DOI: 10.1021/acs.langmuir.1c01687] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Regarding the outbreak of the SARS Cov-2 virus pandemic worldwide, it seems necessary to provide new diagnostic methods to combat the virus. A fluorescence CdTe quantum dots-DNA (QDs-DNA) nanosensor was prepared for efficient detection of a specific target complementary DNA or RNA from the SARS Cov-2 virus using FRET experiment via forming a classic "sandwich" structure. The sequence of the complementary DNA (target DNA) is planned based on a substantial part of the SARS Cov-2 virus genome, and oligonucleotides of QDs-DNA nanoprobe are designed to complement it. The water-soluble CdTe QDs-DNA was prepared by replacing the thioglycolic acid (TGA) on the surface of QDs with capture DNA (thiolated DNA) through a ligand-exchange method. Subsequently, with the addition of complementary (target DNA) and quencher DNA (BHQ2-labeled DNA) into the QDs-DNA conjugates, sandwiched hybrids were formed. The resulting assembly brings the BHQ2-labeled DNA (as the acceptor), and the QDs (as the donor) into proximity, leading to quenching of fluorescence emission from the donor QDs through the FRET mechanism. In other words, a simple, highly sensitive, selective, and rapid approach was introduced to detect complementary DNA sequence from a specific part of the SARS Cov-2 virus genome with a detection limit of 2.52 × 10-9 mol L-1. Furthermore, the planned nanosensor was well used for the detection of RNA from SARS Cov-2 viruses in real samples with satisfactory analytical results, and the outcomes were compared with RT-PCR (Reverse Transcription Polymerase Chain Reaction) as the well-known standard method.
Collapse
Affiliation(s)
| | - Mohammadreza Zamani
- Department of Plant Biotechnology, National Institute for Genetic Engineering and Biotechnology (NIGEB), Tehran, P.O. Box 14155-6343, I.R. of Iran
| | - Mahdieh Sharifi
- Department of Chemistry, Payame Noor University, PO BOX 19395-3697, Tehran, Iran
| |
Collapse
|
8
|
Parani S, Oluwafemi OS. Selective and sensitive fluorescent nanoprobe based on AgInS 2-ZnS quantum dots for the rapid detection of Cr (III) ions in the midst of interfering ions. NANOTECHNOLOGY 2020; 31:395501. [PMID: 32531766 DOI: 10.1088/1361-6528/ab9c58] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
We herein report a novel eco-friendly method for the fluorescent sensing of Cr (III) ions using green synthesized glutathione (GSH) capped water soluble AgInS2-ZnS (AIS-ZnS) quantum dots (QDs). The as-synthesized AIS-ZnS QDs were speherical in shape with average diameter of ∼2.9 nm and exhibited bright yellow emission. The fluorimetric analyses showed that, compared to Cr (VI) ions and other 20 metal ions across the periodic table, AIS-ZnS QDs selectively detected Cr (III) ions via fluorescent quenching. In addition, AIS-ZnS QDs fluorescent nanoprobes exhibited selective detection of Cr (III) ions in the mixture of interfering divalent metal ions such as Cu (II), Pb (II), Hg (II), Ni (II). The mechanism of Cr (III) sensing investigated using HRTEM and FTIR revealed that the binding of Cr (III) ions with the GSH capping group resulted in the aggregation of QDs followed by fluorescence quenching. The limit of detection of Cr (III) ions was calculated to be 0.51 nM. The present method uses cadmium free QDs and paves a greener way for selective determination of Cr (III) ions in the midst of other ions in aqueous solutions.
Collapse
Affiliation(s)
- Sundararajan Parani
- Department of Chemical Sciences (formerly Applied Chemistry), University of Johannesburg, P.O. Box 17011, Doornfontein, 2028, Johannesburg, South Africa. Centre for Nanomaterials Science Research, University of Johannesburg, P.O. Box 17011, Doornfontein, 2028, Johannesburg, South Africa
| | | |
Collapse
|
9
|
Aggarwal R, Hooda M, Kumar P, Sumran G. Solvent-free, Silica Catalyzed Intriguing Conversion of 3-Hydrazonobutan-2-one Oxime into Biacetyl Bis-hydrazone Schiff Bases. LETT ORG CHEM 2020. [DOI: 10.2174/1570178617999200818210859] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
:
An expeditious and operationally simple reaction between 3-hydrazonobutan-2-one oxime and different substituted benzaldehydes in presence of silica afforded an unexpected product, biacetyl bis-hydrazone Schiff bases in good yield
on grinding in a mortar at room temperature, instead of expected product 3-(aryl)methylenehydrazonobutan-2-one oxime.
Mild reaction conditions involving recyclable mineral support silica, environmentally benign and good yield in short reaction time are remarkable advantages of this protocol. Products were characterized by IR, NMR (1H and 13C) and elemental
analyses.
Collapse
Affiliation(s)
- Ranjana Aggarwal
- Department of Chemistry, Kurukshetra University, Kurukshetra 136119, Haryana, India
| | - Mona Hooda
- Department of Chemistry, Kurukshetra University, Kurukshetra 136119, Haryana, India
| | - Prince Kumar
- Department of Chemistry, Kurukshetra University, Kurukshetra 136119, Haryana, India
| | - Garima Sumran
- Department of Chemistry, D. A. V. College (Lahore), Ambala City 134 003, Haryana, India
| |
Collapse
|
10
|
Gold and silver nanoparticles in resonance Rayleigh scattering techniques for chemical sensing and biosensing: a review. Mikrochim Acta 2019; 186:667. [PMID: 31485856 DOI: 10.1007/s00604-019-3755-4] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Accepted: 08/10/2019] [Indexed: 01/08/2023]
Abstract
This review (with 116 refs.) summarizes the state of the art in resonance Rayleigh scattering (RRS)-based analytical methods. Following an introduction into the fundamentals of RRS and on the preparation of metal nanoparticles, a first large section covers RRS detection methods based on the use of gold nanoparticles, with subsections on proteins (albumin, bovine serum albumin and ovalbumin, glycoproteins, folate receptors, iron binding-proteins, G-proteins-coupled receptors, transmembrane proteins, epidermal growth factor receptors), on pesticides, saccharides, vitamins, heavy metal ions (such as mercury, silver, chromium), and on cationic dyes. This is followed by a section on RRS methods based on the use of silver nanoparticles, with subsections on the detection of nucleic acids and insecticides. Several Tables are presented where an RRS method is compared to the performance of other methods. A concluding section summarizes the current status, addresses current challenges, and gives an outlook on potential future trends. Graphical Abstract Change in the resonance Rayleigh scattering (RRS) intensity when mixing the nanoparticles with the specific analyte.
Collapse
|
11
|
De Acha N, Elosúa C, Corres JM, Arregui FJ. Fluorescent Sensors for the Detection of Heavy Metal Ions in Aqueous Media. SENSORS 2019; 19:s19030599. [PMID: 30708989 PMCID: PMC6386841 DOI: 10.3390/s19030599] [Citation(s) in RCA: 117] [Impact Index Per Article: 19.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Revised: 01/17/2019] [Accepted: 01/23/2019] [Indexed: 12/17/2022]
Abstract
Due to the risks that water contamination implies for human health and environmental protection, monitoring the quality of water is a major concern of the present era. Therefore, in recent years several efforts have been dedicated to the development of fast, sensitive, and selective sensors for the detection of heavy metal ions. In particular, fluorescent sensors have gained in popularity due to their interesting features, such as high specificity, sensitivity, and reversibility. Thus, this review is devoted to the recent advances in fluorescent sensors for the monitoring of these contaminants, and special focus is placed on those devices based on fluorescent aptasensors, quantum dots, and organic dyes.
Collapse
Affiliation(s)
- Nerea De Acha
- Department of Electric, Electronic and Communications Engineering, Public University of Navarra, E-31006 Pamplona, Spain.
| | - César Elosúa
- Department of Electric, Electronic and Communications Engineering, Public University of Navarra, E-31006 Pamplona, Spain.
- Institute of Smart Cities (ISC), Public University of Navarra, E-31006 Pamplona, Spain.
| | - Jesús M Corres
- Department of Electric, Electronic and Communications Engineering, Public University of Navarra, E-31006 Pamplona, Spain.
- Institute of Smart Cities (ISC), Public University of Navarra, E-31006 Pamplona, Spain.
| | - Francisco J Arregui
- Department of Electric, Electronic and Communications Engineering, Public University of Navarra, E-31006 Pamplona, Spain.
- Institute of Smart Cities (ISC), Public University of Navarra, E-31006 Pamplona, Spain.
| |
Collapse
|
12
|
|