1
|
Saini R, Railton P, Boyd J, Sadrzadeh H, Powell JN. Concordance between laboratories in metal ion testing in patients with metal-on-metal hip implants. Can J Surg 2019; 62:9-13. [PMID: 30265641 DOI: 10.1503/cjs.015717] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Testing of whole blood or serum metal ion levels has become an important part of assessing and monitoring the performance of metal-on-metal bearings, both in hip resurfacing arthroplasty and in total hip replacement. The aim of this study was to determine the concordance between 2 laboratories testing cobalt and chromium ion levels in patients with metal-on-metal bearings. METHODS Serum and whole blood samples from patients who had undergone metal-on-metal resurfacing or large-diameter total hip arthroplasty were tested for cobalt and chromium ions in laboratory A (a recognized laboratory) and laboratory B (tasked with testing clinical specimens). Laboratory A performed cobalt and chromium testing on whole blood, and laboratory B performed cobalt testing on whole blood and chromium testing on serum. RESULTS Samples from 104 patients were tested. Laboratory B reported lower whole blood cobalt levels than laboratory A. Furthermore, laboratory A reported that all patients had elevated whole blood cobalt ion levels compared to the normal reference values for the laboratory, whereas laboratory B reported that 46 patients (44.2%) had whole blood cobalt ion levels within the normal reference range for the laboratory. CONCLUSION This comparative study highlights the importance of using a single laboratory for metal ion testing, as values generated from different laboratories may not be directly comparable. With recent literature suggesting that whole blood cobalt levels as low as 1 ppb may be a predictor of adverse reactions to metal debris, accurate clinical measurement needs to be increasingly exact.
Collapse
Affiliation(s)
- Raghav Saini
- From the Cumming School of Medicine, University of Calgary, Calgary, Alta. (Powell, Saini, Boyd, Railton); and Calgary Laboratory Services, Calgary, Alta. (Sadrzadeh)
| | - Pam Railton
- From the Cumming School of Medicine, University of Calgary, Calgary, Alta. (Powell, Saini, Boyd, Railton); and Calgary Laboratory Services, Calgary, Alta. (Sadrzadeh)
| | - Jessica Boyd
- From the Cumming School of Medicine, University of Calgary, Calgary, Alta. (Powell, Saini, Boyd, Railton); and Calgary Laboratory Services, Calgary, Alta. (Sadrzadeh)
| | - Hossein Sadrzadeh
- From the Cumming School of Medicine, University of Calgary, Calgary, Alta. (Powell, Saini, Boyd, Railton); and Calgary Laboratory Services, Calgary, Alta. (Sadrzadeh)
| | - James N Powell
- From the Cumming School of Medicine, University of Calgary, Calgary, Alta. (Powell, Saini, Boyd, Railton); and Calgary Laboratory Services, Calgary, Alta. (Sadrzadeh)
| |
Collapse
|
2
|
The value of serial metal ion levels in following up patients with metal-on-metal hip arthroplasty. Hip Int 2017; 27:14-20. [PMID: 28106230 DOI: 10.5301/hipint.5000432] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 06/17/2016] [Indexed: 02/04/2023]
Abstract
BACKGROUND The sensitivity of cobalt (Co) and chromium (Cr) ion-levels in detecting poorly performing metal-on-metal hip implants is low. This study proposes that serial changes in ion-levels are a more accurate marker of arthroplasties at risk. METHODS Serial metal ion-levels and implant data of 285 patients with ASR resurfacing or replacement were studied. Patient and implant characteristics were analysed using univariate and multivariate analyses. RESULTS 111 (39%) had revision surgery. Time since index surgery (p<0.001), acetabular inclination (p<0.001), their interaction (p<0.001) and femoral head size (p = 0.01) were significant variables. Head size (≤51 mm) had lower Co and Cr levels (p = 0.01). Cr/Co showed marginal decrease over time in the unrevised group and no decrease prerevision. CONCLUSIONS Repeated measurement of ion-levels were higher in the revision group suggesting that serial measurements rather than absolute values may have a role to play in predicting implant failure.
Collapse
|
3
|
The Prevalence of Positive Findings on Metal Artifact Reduction Sequence Magnetic Resonance Imaging in Metal-on-Metal Total Hip Arthroplasty. J Arthroplasty 2016; 31:1519-23. [PMID: 26876943 DOI: 10.1016/j.arth.2016.01.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2015] [Revised: 12/28/2015] [Accepted: 01/13/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND We sought to assess the prevalence of soft tissue changes seen on magnetic resonance imaging (MRI) after metal-on-metal (MOM) total hip arthroplasty (THA) and determine if the presence of pseudotumors was associated with metal ion levels, acetabular cup position, outcomes scores, and femoral head size. METHODS After receiving an institutional review board exemption for secondary data analysis, we performed a cross-sectional study identifying 55 patients (55 hips) that underwent primary THA with a MOM articulation and had subsequent MRI imaging between February 2013 and February 2014 at a single academic medical center. RESULTS Twenty-four patients (44%) had no evidence of pseudotumors, 27 (49%) had type I pseudotumors, and 4 (7%) were classified as having type II pseudotumors. The presence and severity of pseudotumors were associated with higher serum chromium levels (P = .043). Neither acetabular inclination nor acetabular version was associated with the presence of pseudotumors, the severity of pseudotumors, or elevated serum metal ion levels (all P > .05). Increased metal ion levels were associated with lower Harris Hip Score and higher Harris Hip Score pain subscores (all P < .05). CONCLUSION In conclusion, pseudotumors on metal artifact reduction sequencing MRI may be present in both symptomatic and asymptomatic MOM THAs. Surgeons should therefore exercise caution in placing too much emphasis on isolated studies such as cross-sectional imaging. Instead, a structured approach to evaluation of MOM arthroplasty should be followed.
Collapse
|
4
|
Lainiala O, Eskelinen A, Elo P, Puolakka T, Korhonen J, Moilanen T. Adverse reaction to metal debris is more common in patients following MoM total hip replacement with a 36 mm femoral head than previously thought. Bone Joint J 2014; 96-B:1610-7. [DOI: 10.1302/0301-620x.96b12.33742] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
We conducted a retrospective study to assess the prevalence of adverse reactions to metal debris (ARMD) in patients operated on at our institution with metal-on-metal (MoM) total hip replacements with 36 mm heads using a Pinnacle acetabular shell. A total of 326 patients (150 males, 175 hips; 176 females, 203 hips) with a mean age of 62.7 years (28 to 85) and mean follow-up of 7.5 years (0.1 to 10.8) participating in our in-depth modern MoM follow-up programme were included in the study, which involved recording whole blood cobalt and chromium ion measurements, Oxford hip scores (OHS) and plain radiographs of the hip and targeted cross-sectional imaging. Elevated blood metal ion levels (> 5 parts per billion) were seen in 32 (16.1%) of the 199 patients who underwent unilateral replacement. At 23 months after the start of our modern MoM follow-up programme, 29 new cases of ARMD had been revealed. Hence, the nine-year survival of this cohort declined from 96% (95% CI 95 to 98) with the old surveillance routine to 86% (95% CI 82 to 90) following the new protocol. Although ARMD may not be as common in 36 mm MoM THRs as in those with larger heads, these results support the Medicines and Healthcare Products Regulatory Agency guidelines on regular reviews and further investigations, and emphasise the need for specific a follow-up programme for patients with MoM THRs. Cite this article: Bone Joint J 2014; 96-B:1610–17.
Collapse
Affiliation(s)
- O. Lainiala
- Coxa Hospital for Joint Replacement, Biokatu
6, 33520 Tampere, Finland
| | - A. Eskelinen
- Coxa Hospital for Joint Replacement, Biokatu
6, 33520 Tampere, Finland
| | - P. Elo
- Coxa Hospital for Joint Replacement, Biokatu
6, 33520 Tampere, Finland
| | - T. Puolakka
- Coxa Hospital for Joint Replacement, Biokatu
6, 33520 Tampere, Finland
| | - J. Korhonen
- Coxa Hospital for Joint Replacement, Biokatu
6, 33520 Tampere, Finland
| | - T. Moilanen
- Coxa Hospital for Joint Replacement, Biokatu
6, 33520 Tampere, Finland
| |
Collapse
|
5
|
Büttner-Janz K, Guyer RD, Ohnmeiss DD. Indications for lumbar total disc replacement: selecting the right patient with the right indication for the right total disc. Int J Spine Surg 2014; 8:14444-1012. [PMID: 25694946 PMCID: PMC4325514 DOI: 10.14444/1012] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023] Open
Abstract
Summary of Background Data As with any surgery, care should be taken to determine patient selection criteria for lumbar TDR based on safety and optimizing outcome. These goals may initially be addressed by analyzing biomechanical implant function and early clinical experience, ongoing evaluation is needed to refine indications. Objective The purpose of this work was to synthesize information published on general indications for lumbar TDR. A secondary objective was to determine if indications vary for different TDR designs. Methods A comprehensive literature search was conducted to identify lumbar TDR articles. Articles were reviewed and patient selection criteria and indications were synthesized. Results With respect to safety, there was good agreement in the literature to exclude patients with osteopenia/osteoporosis or fracture. Risk of injury to vascular structures due to the anterior approach was often addressed by excluding patients with previous abdominal surgery in the area of disc pathology or increased age. The literature was very consistent on the primary indication for TDR being painful disc degeneration unresponsive to at least 6 months of nonoperative care. Literature investigating the impact of previous spine surgery was mixed; however, prior surgery was not necessarily a contra-indication, provided the patient otherwise met selection criteria. The literature was mixed on setting a minimum preoperative disc height as a selection criterion. There were no publications investigating whether some patients are better/worse candidates for specific TDR designs. Based on the literature a proposal for patient selection criteria is offered. Conclusions Several TDR indications and contra-indications are widely accepted. No literature addresses particular TDR design being preferable for some patients. As with any spine surgery, ongoing evaluation of TDR outcomes will likely lead to more detailed general and device design specific indications.
Collapse
|
6
|
Serum metal ion concentrations in paediatric patients following total knee arthroplasty using megaprostheses. BIOMED RESEARCH INTERNATIONAL 2014; 2014:817257. [PMID: 25276819 PMCID: PMC4172978 DOI: 10.1155/2014/817257] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/18/2014] [Revised: 07/17/2014] [Accepted: 08/11/2014] [Indexed: 11/18/2022]
Abstract
The purpose of this study was to determine the concentrations of cobalt, chromium, and molybdenum in the serum of paediatric tumour patients after fixed hinge total knee arthroplasty. Further, these metal ion levels were compared with serum metal ion levels of patients with other orthopaedic devices such as hip and knee prostheses with metal-on-metal or metal-on-polyethylene articulation to find differences between anatomical locations, abrasion characteristics, and bearing surfaces. After an average follow-up of 108 months (range: 67 to 163) of 11 paediatric patients with fixed hinge total knee arthroplasty, the mean concentrations for Co and Cr were significantly increased while Mo was within the limits compared to the upper values from the reference laboratory. Furthermore, these serum concentrations were significantly higher compared to patients with a standard rotating hinge device (P = 0.002 and P < 0.001) and preoperative controls (P < 0.001). On the other hand, the serum levels of patients following MoM THA or rotating hinge arthroplasty using megaprostheses were higher. Therefore, periodic long-term follow-ups are recommended due to the rising concerns about systemic metal ion exposure in the literature. Upon the occurrence of adverse reactions to metal debris the revision of the fixed hinge implant should be considered.
Collapse
|
7
|
Lass R, Grübl A, Kolb A, Stelzeneder D, Pilger A, Kubista B, Giurea A, Windhager R. Comparison of synovial fluid, urine, and serum ion levels in metal-on-metal total hip arthroplasty at a minimum follow-up of 18 years. J Orthop Res 2014; 32:1234-1240. [PMID: 24841922 DOI: 10.1002/jor.22652] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2014] [Accepted: 05/02/2014] [Indexed: 02/04/2023]
Abstract
Diagnosis of adverse reactions to metal debris in metal-on-metal hip arthroplasty is a multifactorial process. Systemic ion levels are just one factor in the evaluation and should not be relied upon solely to determine the need for revision surgery. Furthermore, the correlation between cobalt or chromium serum, urine, or synovial fluid levels and adverse local tissue reactions is still incompletely understood. The hypothesis was that elevated serum and urine metal-ion concentrations are associated with elevated local metal-ion concentrations in primary total hip arthroplasties (THA) and with failure of metal-on-metal articulations in the long-term. In our present study, we evaluated these concentrations in 105 cementless THA with metal-on-metal articulating surfaces with small head diameter at a minimum of 18 years postoperatively. Spearman correlation showed a high correlation between the joint fluid aspirate concentration of cobalt and chromium with the serum cobalt (r = 0.81) and chromium level (r = 0.77) in patients with the THA as the only source of metal-ions. In these patients serum metal-ion analysis is a valuable method for screening. In patients with more than one source of metal or renal insufficiency additional investigations, like joint aspirations are an important tool for evaluation of wear and adverse tissue reactions in metal-on-metal THA.
Collapse
Affiliation(s)
- Richard Lass
- Department of Orthopaedics, Medical University of Vienna, Währinger Gürtel 18-20, A-1090, Vienna, Austria
| | | | | | | | | | | | | | | |
Collapse
|
8
|
Matusiewicz H. Potential release of in vivo trace metals from metallic medical implants in the human body: from ions to nanoparticles--a systematic analytical review. Acta Biomater 2014; 10:2379-403. [PMID: 24565531 DOI: 10.1016/j.actbio.2014.02.027] [Citation(s) in RCA: 124] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2013] [Revised: 12/04/2013] [Accepted: 02/13/2014] [Indexed: 02/06/2023]
Abstract
Metal ion release from metallic materials, e.g. metallic alloys and pure metals, implanted into the human body in dental and orthopedic surgery is becoming a major cause for concern. This review briefly provides an overview of both metallic alloys and pure metals used in implant materials in dental and orthopedic surgery. Additionally, a short section is dedicated to important biomaterials and their corrosive behavior in both real solutions and various types of media that model human biological fluids and tissues. The present review gives an overview of analytical methods, techniques and different approaches applied to the measurement of in vivo trace metals released into body fluids and tissues from patients carrying metal-on-metal prostheses and metal dental implants. Reference levels of ion concentrations in body fluids and tissues that have been determined by a host of studies are compiled, reviewed and presented in this paper. Finally, a collection of published clinical data on in vivo released trace metals from metallic medical implants is included.
Collapse
|
9
|
Lass R, Grübl A, Kolb A, Domayer S, Csuk C, Kubista B, Giurea A, Windhager R. Primary cementless total hip arthroplasty with second-generation metal-on-metal bearings: a concise follow-up, at a minimum of seventeen years, of a previous report. J Bone Joint Surg Am 2014; 96:e37. [PMID: 24599209 DOI: 10.2106/jbjs.m.00748] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Second-generation, metal-on-metal bearings were introduced in 1988, to reduce wear and avoid polyethylene particle-induced osteolysis from total hip arthroplasty. In 2007, we reported the long-term results of ninety-eight patients (105 hips) who underwent primary cementless total hip arthroplasty involving the use of a prosthesis with a high-carbide-concentration, metal-on-metal articulating surface between November 1992 and May 1994. The present study gives an update on this patient cohort. METHODS At a minimum of seventeen years postoperatively, forty-nine patients (fifty-two hips) were available for follow-up examination. We retrospectively evaluated clinical and radiographic results as well as serum metal concentration. The mean patient age at the time of the index arthroplasty was fifty-six years. RESULTS Three cups (6% of the hips) and one stem (2% of the hips) were revised because of aseptic loosening of the implants combined with focal osteolysis. At the time of the latest follow-up evaluation, the mean Harris hip score was 88.8 points, and the mean University of California Los Angeles (UCLA) activity score was 6.7 points. The cumulative rate of implant survival, with aseptic failure as the end point, was 93.0% at 18.8 years. The median serum cobalt concentration in patients whose hip implant was the only source of cobalt was 0.70 μg/L (range, 0.4 to 5.1 μg/L), showing no increase in the value as noted at a minimum of ten years of follow-up. CONCLUSIONS The clinical and radiographic results of our study, which, to our knowledge, represent the longest duration of follow-up for a series of cementless total hip arthroplasties with use of a 28-mm metal-on-metal bearing, continue to be comparable with the results observed for other hard-on-hard bearings.
Collapse
Affiliation(s)
- R Lass
- Department of Orthopedics, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria. E-mail address for R. Lass:
| | - A Grübl
- Sanatorium Hera, Löblichgasse 14, A-1090 Vienna, Austria
| | - A Kolb
- Department of Orthopedics, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria. E-mail address for R. Lass:
| | - S Domayer
- Department of Orthopedics, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria. E-mail address for R. Lass:
| | - C Csuk
- Department of Orthopedics, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria. E-mail address for R. Lass:
| | - B Kubista
- Department of Orthopedics, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria. E-mail address for R. Lass:
| | - A Giurea
- Department of Orthopedics, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria. E-mail address for R. Lass:
| | - R Windhager
- Department of Orthopedics, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria. E-mail address for R. Lass:
| |
Collapse
|
10
|
Hartmann A, Hannemann F, Lützner J, Seidler A, Drexler H, Günther KP, Schmitt J. Metal ion concentrations in body fluids after implantation of hip replacements with metal-on-metal bearing--systematic review of clinical and epidemiological studies. PLoS One 2013; 8:e70359. [PMID: 23950923 PMCID: PMC3737219 DOI: 10.1371/journal.pone.0070359] [Citation(s) in RCA: 75] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2013] [Accepted: 06/16/2013] [Indexed: 01/02/2023] Open
Abstract
INTRODUCTION The use of metal-on-metal (MoM) total hip arthroplasty (THA) increased in the last decades. A release of metal products (i.e. particles, ions, metallo-organic compounds) in these implants may cause local and/or systemic adverse reactions. Metal ion concentrations in body fluids are surrogate measures of metal exposure. OBJECTIVE To systematically summarize and critically appraise published studies concerning metal ion concentrations after MoM THA. METHODS Systematic review of clinical trials (RCTs) and epidemiological studies with assessment of metal ion levels (cobalt, chromium, titanium, nickel, molybdenum) in body fluids after implantation of metalliferous hip replacements. Systematic search in PubMed and Embase in January 2012 supplemented by hand search. Standardized abstraction of pre- and postoperative metal ion concentrations stratified by type of bearing (primary explanatory factor), patient characteristics as well as study quality characteristics (secondary explanatory factors). RESULTS Overall, 104 studies (11 RCTs, 93 epidemiological studies) totaling 9.957 patients with measurement of metal ions in body fluids were identified and analyzed. Consistently, median metal ion concentrations were persistently elevated after implantation of MoM-bearings in all investigated mediums (whole blood, serum, plasma, erythrocytes, urine) irrespective of patient characteristics and study characteristics. In several studies very high serum cobalt concentrations above 50 µg/L were measured (detection limit typically 0.3 µg/L). Highest metal ion concentrations were observed after treatment with stemmed large-head MoM-implants and hip resurfacing arthroplasty. DISCUSSION Due to the risk of local and systemic accumulation of metallic products after treatment with MoM-bearing, risk and benefits should be carefully balanced preoperatively. The authors support a proposed "time out" for stemmed large-head MoM-THA and recommend a restricted indication for hip resurfacing arthroplasty. Patients with implanted MoM-bearing should receive regular and standardized monitoring of metal ion concentrations. Further research is indicated especially with regard to potential systemic reactions due to accumulation of metal products.
Collapse
Affiliation(s)
- Albrecht Hartmann
- University Hospital Carl Gustav Carus Dresden, University Centre for Orthopaedics and Trauma Surgery, Dresden, Germany
| | - Franziska Hannemann
- University Hospital Carl Gustav Carus Dresden, University Centre for Orthopaedics and Trauma Surgery, Dresden, Germany
- University Hospital Carl Gustav Carus Dresden, Centre for Evidence-Based Health Care, Dresden, Germany
| | - Jörg Lützner
- University Hospital Carl Gustav Carus Dresden, University Centre for Orthopaedics and Trauma Surgery, Dresden, Germany
| | - Andreas Seidler
- Dresden University of Technology, Occupational and Social Medicine, Dresden, Germany
| | - Hans Drexler
- University Erlangen-Nuremberg, Occupational, Social and Environmental Medicine, Erlangen, Germany
| | - Klaus-Peter Günther
- University Hospital Carl Gustav Carus Dresden, University Centre for Orthopaedics and Trauma Surgery, Dresden, Germany
| | - Jochen Schmitt
- University Hospital Carl Gustav Carus Dresden, Centre for Evidence-Based Health Care, Dresden, Germany
- Dresden University of Technology, Occupational and Social Medicine, Dresden, Germany
| |
Collapse
|
11
|
Jantzen C, Jørgensen HL, Duus BR, Sporring SL, Lauritzen JB. Chromium and cobalt ion concentrations in blood and serum following various types of metal-on-metal hip arthroplasties: a literature overview. Acta Orthop 2013; 84:229-36. [PMID: 23594249 PMCID: PMC3715816 DOI: 10.3109/17453674.2013.792034] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Widely different metal ion concentrations in blood and serum have been reported with metal-on-metal (MoM) implants. We reviewed the literature on blood and serum ion concentrations of chromium (Cr) and cobalt (Co) following various MoM hip arthroplasties. METHODS Studies were searched for in the Medline database, Embase, and the Cochrane Database of Systematic Reviews. Highest mean or median ion concentrations of Cr and Co after a minimum of 1 year of follow-up were extracted and grouped according to sample- and articulation type, and average values were calculated. RESULTS 43 studies were included and 16 different MoM implants were identified. For the different types of bearings, average ion concentrations and range were calculated from the mean or median ion concentration. The average Cr concentration ranged between 0.5 and 2.5 μg/L in blood and between 0.8 and 5.1 μg/L in serum. For Co, the range was 0.7-3.4 μg/L in blood and 0.3-7.5 μg/L in serum. INTERPRETATION When the average blood ion concentrations calculated for the different implants, together with the concentrations measured in the individual studies, were compared with the upper acceptable limit for Cr and Co in blood, no clear pattern was recognized. Furthermore, we were unable to detect any clear difference in ion concentrations between different types of implants (THA and resurfacing).
Collapse
Affiliation(s)
| | - Henrik L Jørgensen
- Clinical Biochemistry, Bispebjerg Hospital, University of Copenhagen, Copenhagen, Denmark
| | | | | | | |
Collapse
|
12
|
Cai G, Zhu J, Shen C, Cui Y, Du J, Chen X. The effects of cobalt on the development, oxidative stress, and apoptosis in zebrafish embryos. Biol Trace Elem Res 2012; 150:200-7. [PMID: 22983774 DOI: 10.1007/s12011-012-9506-6] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2012] [Accepted: 09/04/2012] [Indexed: 11/29/2022]
Abstract
Metal-on-metal hip arthroplasty has been performed with increasing frequency throughout the world, particularly in younger and more active patients, including women of childbearing age. The potential toxicity of cobalt exposure on fetus is concerned since cobalt ions generated by metal-on-metal bearings can traverse the placenta and be detected in fetal blood and amniotic fluid. This study examined the effects of cobalt exposure on early embryonic development and the mechanisms underlying its toxicity. Zebrafish embryos were exposed to a range of cobalt concentrations (0-100 mg/L) between 1 and 144 h postfertilization. The survival and early development of embryos were not significantly affected by cobalt at concentrations <100 μg/L. However, embryos exposed to higher concentrations (>100 μg/L) displayed reduced survival rates and abnormal development, including delayed hatching, aberrant morphology, retarded growth, and bradycardia. Furthermore, this study examined oxidative stress and apoptosis in embryos exposed to cobalt at concentrations of 0-500 μg/L. Lipid peroxidation levels were increased in cobalt-treated embryos at concentrations of 100 and 500 μg/L. The mRNA levels of catalase, superoxide dismutase 2, p53, caspase-3, and caspase-9 genes were upregulated in a dose-dependent manner. Terminal deoxynucleotidyl transferase-mediated dUTP nick end labeling assays also revealed abnormal apoptotic signals in the brain, trunk, and tail when treated with 500 μg/L cobalt. These data suggest that oxidative stress and apoptosis are associated with cobalt toxicity in zebrafish embryos.
Collapse
Affiliation(s)
- Guiquan Cai
- Department of Orthopaedics, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, 1665 Kong-Jiang Road, Shanghai, 200092, China
| | | | | | | | | | | |
Collapse
|
13
|
Liu F, Chen Z, Gu Y, Wang Q, Cui W, Fan W. Deformation of the Durom acetabular component and its impact on tribology in a cadaveric model--a simulator study. PLoS One 2012; 7:e45786. [PMID: 23144694 PMCID: PMC3483233 DOI: 10.1371/journal.pone.0045786] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2012] [Accepted: 08/22/2012] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Recent studies have shown that the acetabular component frequently becomes deformed during press-fit insertion. The aim of this study was to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the Durom large head metal-on-metal (MOM) total hips in simulators. METHODS Six Durom cups impacted into reamed acetabula of fresh cadavers were used as the experimental group and another 6 size-paired intact Durom cups constituted the control group. All 12 Durom MOM total hips were put through a 3 million cycle (MC) wear test in simulators. RESULTS The 6 cups in the experimental group were all deformed, with a mean deformation of 41.78 ± 8.86 µm. The average volumetric wear rate in the experimental group and in the control group in the first million cycle was 6.65 ± 0.29 mm(3)/MC and 0.89 ± 0.04 mm(3)/MC (t = 48.43, p = 0.000). The ion levels of Cr and Co in the experimental group were also higher than those in the control group before 2.0 MC. However there was no difference in the ion levels between 2.0 and 3.0 MC. CONCLUSIONS This finding implies that the non-modular acetabular component of Durom total hip prosthesis is likely to become deformed during press-fit insertion, and that the deformation will result in increased volumetric wear and increased ion release. CLINICAL RELEVANCE This study was determined to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the prosthesis. Deformation of the cup after implantation increases the wear of MOM bearings and the resulting ion levels. The clinical use of the Durom large head prosthesis should be with great care.
Collapse
Affiliation(s)
- Feng Liu
- Department of Orthopedics, the First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | | | | | | | | | | |
Collapse
|
14
|
Fritzsche J, Borisch C, Schaefer C. Case report: High chromium and cobalt levels in a pregnant patient with bilateral metal-on-metal hip arthroplasties. Clin Orthop Relat Res 2012; 470:2325-31. [PMID: 22692823 PMCID: PMC3392404 DOI: 10.1007/s11999-012-2398-0] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2012] [Accepted: 05/10/2012] [Indexed: 01/31/2023]
Abstract
BACKGROUND Metal-on-metal bearings frequently are used in young patients leading to the concern that disseminated metals such as chromium (Cr) and cobalt (Co) as the main constituents could affect pregnancies. CASE DESCRIPTION We describe a 41-year-old patient with bilateral metal-on-metal hip arthroplasties, a recurrent pseudotumor, and extremely high blood levels (Cr 39 μg/L, Co 138 μg/L) at 12 gestational weeks. At different gestational weeks, maternal blood, aspirate of the pseudotumor, and amniotic fluid were analyzed for Cr and Co. Therapy with chelating agents was not recommended because the mother showed no symptoms of toxicity and the safety of chelating therapy during pregnancy is not established. At 38 weeks of gestation, a healthy male infant was delivered with elevated Cr and Co cord blood levels. At the age of 8 weeks, the infant's Cr was comparable to the cord blood level, whereas the Co decreased considerably without treatment. At the age of 14 weeks, the infant's development was seemingly uneventful and no signs of toxicity were obvious. LITERATURE REVIEW Carcinogenic, mutagenic, and teratogenic potentials of these metals have been suggested. However, we found no published clinical observations in context with pregnancies of women with hip arthroplasties using metal-on-metal implants. To our knowledge, this is the first report of such high levels of Cr and Co in a human pregnancy. PURPOSES AND CLINICAL RELEVANCE Although we cannot generalize from one case, the seemingly uneventful outcome of this pregnancy may reassure colleagues when counseling patients with high ion levels whether to carry a pregnancy to term.
Collapse
Affiliation(s)
- Juliane Fritzsche
- Pharmakovigilanz- und Beratungszentrum für Embryonaltoxikologie (Institute for Clinical Teratology and Drug Risk Assessment in Pregnancy), Institut für Klinische Pharmakologie und Toxikologie, Charité Universitätsmedizin Berlin, Spandauer Damm 130, Haus 10, D-14050 Berlin, Germany
| | - Cornelia Borisch
- Pharmakovigilanz- und Beratungszentrum für Embryonaltoxikologie (Institute for Clinical Teratology and Drug Risk Assessment in Pregnancy), Institut für Klinische Pharmakologie und Toxikologie, Charité Universitätsmedizin Berlin, Spandauer Damm 130, Haus 10, D-14050 Berlin, Germany
| | - Christof Schaefer
- Pharmakovigilanz- und Beratungszentrum für Embryonaltoxikologie (Institute for Clinical Teratology and Drug Risk Assessment in Pregnancy), Institut für Klinische Pharmakologie und Toxikologie, Charité Universitätsmedizin Berlin, Spandauer Damm 130, Haus 10, D-14050 Berlin, Germany
| |
Collapse
|
15
|
Hasegawa M, Yoshida K, Wakabayashi H, Sudo A. Cobalt and chromium ion release after large-diameter metal-on-metal total hip arthroplasty. J Arthroplasty 2012; 27:990-6. [PMID: 22325959 DOI: 10.1016/j.arth.2011.12.016] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2011] [Accepted: 12/12/2011] [Indexed: 02/01/2023] Open
Abstract
Seventy-five patients underwent unilateral metal-on-metal total hip arthroplasty using a large-diameter head. Serum levels of cobalt and chromium were determined. Significant increases in both cobalt and chromium were observed at 3 months (cobalt, 1.4 μg/L; chromium, 1.4 μg/L) compared with preoperative values (P < .001). At 1 year, the median cobalt and chromium levels were 2.3 and 2.1 μg/L, respectively, and the levels had increased significantly compared with 3 months (P < .001). There were no significant differences between levels of either metal at 1 or 2 years (cobalt, 2.3 μg/L; chromium, 1.6 μg/L). Pseudotumor occurred in 2 hips. Patients with large-diameter metal-on-metal total hip arthroplasty had higher circulating metal ion levels at 3 months and 1 year, with no additional significant increases at 2 years.
Collapse
Affiliation(s)
- Masahiro Hasegawa
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Tsu City, Mie, Japan
| | | | | | | |
Collapse
|
16
|
Maurer-Ertl W, Friesenbichler J, Sadoghi P, Pechmann M, Trennheuser M, Leithner A. Metal ion levels in large-diameter total hip and resurfacing hip arthroplasty--preliminary results of a prospective five year study after two years of follow-up. BMC Musculoskelet Disord 2012; 13:56. [PMID: 22494794 PMCID: PMC3490776 DOI: 10.1186/1471-2474-13-56] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/03/2011] [Accepted: 03/27/2012] [Indexed: 01/15/2023] Open
Abstract
Background Metal-on-metal hip resurfacing is an alternative to metal-on-metal total hip arthroplasty, especially for young and physically active patients. However, wear which might be detected by increased serum ion levels is a matter of concern. Methods The aims of this preliminary study were to determine the raise of metal ion levels at 2-years follow-up in a prospective setting and to evaluate differences between patients with either resurfacing or total hip arthroplasty. Furthermore we investigated if the inclination of the acetabular component and the arc of cover would influence these findings. Therefore, 36 patients were followed prospectively. Results The results showed increments for Co and Cr in both implant groups. Patients treated with large-diameter total hip arthroplasty showed fourfold and threefold, respectively, higher levels for Co and Cr compared to the resurfacing group (Co: p < 0,001 and Cr: p = 0,005). Nevertheless, we observed no significant correlation between serum ion levels, inclination and arc of cover. Discussion In order to clarify the biologic effects of ion dissemination and to identify risks concerning long-term toxicity of metals, the exposure should be monitored carefully. Therefore, long-term studies have to be done to determine adverse effects of Co and Cr following metal-on-metal hip replacement.
Collapse
Affiliation(s)
- W Maurer-Ertl
- Department of Orthopaedic Surgery, Medical University of Graz, Graz, Austria
| | | | | | | | | | | |
Collapse
|
17
|
Neuerburg C, Impellizzeri F, Goldhahn J, Frey P, Naal FD, von Knoch M, Leunig M, von Knoch F. Survivorship of second-generation metal-on-metal primary total hip replacement. Arch Orthop Trauma Surg 2012; 132:527-33. [PMID: 22094796 DOI: 10.1007/s00402-011-1427-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2011] [Indexed: 01/12/2023]
Abstract
BACKGROUND Second generation metal-on-metal total hip replacements (THR) were introduced in the late 1980s and various studies reported conflicting data on their outcome. METHODS Implant survival of 1,270 second-generation 28 mm metal-on-metal primary THR in 1,121 patients followed prospectively at a mean of 6.8 years postoperatively was evaluated retrospectively. The probability of survival at 10 years was estimated using the method of Kaplan and Meier, and relative risk factors including age, gender, BMI, type of implant fixation and component size were calculated using the Cox proportional-hazards model. RESULTS Sixty-three (5%) THRs were revised, these being 28 hips for aseptic loosening and 35 for reasons other than aseptic loosening. The probability of survival at 10 years, with revision for any reason as the endpoint, was 0.90 (95% confidence interval (CI) 0.86-0.94) for the THR as a whole, 0.91 (95% CI 0.87-0.95) for the cup, and 0.96 (95% CI 0.94-0.98) for the stem. No demographic factors or covariates were found to significantly affect the implant survivorship. DISCUSSION As there was no superior probability of survival, and there have been concerns on putative local and systemic toxicity of metal debris, the use of second-generation metal-on-metal articulations for primary THR remains moot.
Collapse
|
18
|
Pei KL, Kinniburgh DW, Butlin L, Faris P, Lee D, Marshall DA, Oliver MC, Parker R, Powell JN, Railton P, Smith J. An ORS-ICP-MS method for monitoring trace levels of cobalt and chromium in whole blood samples from hip arthroplasty patients with metal-on-metal prostheses. Clin Biochem 2012; 45:806-10. [PMID: 22484458 DOI: 10.1016/j.clinbiochem.2012.03.025] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2011] [Revised: 03/14/2012] [Accepted: 03/21/2012] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To develop a rapid and reliable method, using an octopole reaction system (ORS) ICP-MS, capable of monitoring trace levels of Co and Cr in whole blood samples from hip arthroplasty patients with metal-on-metal prostheses. DESIGN AND METHOD Whole blood is diluted 10-fold with an alkaline diluent and analyzed using an Agilent 7500 CE ORS-ICP-MS. RESULTS Limit of quantification of 0.03 μg/L Co and 0.20 μg/L Cr in patient samples. <6% covariance obtained for quality control materials analyzed over 10 runs. CONCLUSION This method is capable of monitoring trace levels of Co and Cr in diluted whole blood samples with a vial to vial run time of approximately 2 min. Results are comparable to those obtained using high resolution (HR) ICP-MS with sample digestion.
Collapse
Affiliation(s)
- K L Pei
- Alberta Centre for Toxicology, University of Calgary, Calgary, AB, Canada
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Mansfield LE, Urrea L, Hutteman HR. Tolerance to cobalt after immunotherapy for cobalt hypersensitivity. Ann Allergy Asthma Immunol 2012; 108:382-3. [PMID: 22541415 DOI: 10.1016/j.anai.2012.02.020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2012] [Revised: 02/14/2012] [Accepted: 02/22/2012] [Indexed: 11/26/2022]
|
20
|
Serum metal ion concentrations after unilateral vs bilateral large-head metal-on-metal primary total hip arthroplasty. J Arthroplasty 2011; 26:1494-500. [PMID: 21570800 DOI: 10.1016/j.arth.2011.03.037] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2011] [Accepted: 03/24/2011] [Indexed: 02/01/2023] Open
Abstract
It is unknown if the presence of bilateral well-functioning large-head metal-on-metal (MOM) total hip arthroplasties (THAs) leads to higher serum metal ion concentrations than unilateral MOM THA. Elevated levels (chromium, 17 μg/L; cobalt, 19 μg/L) have been associated with poorly functioning MOM THA with metallosis. Fourteen patients having undergone bilateral and 25 patients having undergone unilateral large-head primary MOM THA were compared. Harris Hip Scores, University of California Los Angeles activity scores, radiographs, serum creatinine, and serum cobalt and chromium levels were obtained. Only cobalt ion levels were significantly higher in the bilateral group than in the unilateral group (1.8 μg/L vs 1.0 μg/L, P = .029). Comparatively, this magnitude is clinically rather low because ion levels did not approach those associated with metallosis in either group. We conclude that although patients with well-functioning bilateral MOM THA may have slightly higher cobalt levels, neither cobalt nor chromium levels approach those seen in poorly functioning MOM THA with metallosis.
Collapse
|
21
|
Qu X, Huang X, Dai K. Metal-on-metal or metal-on-polyethylene for total hip arthroplasty: a meta-analysis of prospective randomized studies. Arch Orthop Trauma Surg 2011; 131:1573-83. [PMID: 21643799 DOI: 10.1007/s00402-011-1325-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2011] [Indexed: 11/29/2022]
Abstract
BACKGROUND There has been recent concern regarding the increased use of metal-on-metal total hip arthroplasty (MOM-THA) as an alternative to contemporary metal-on-polyethylene total hip arthroplasty (MOP-THA), and the choice remains controversial. We performed a meta-analysis to evaluate and compare metal ion concentrations, complications, reoperation rates, clinical outcomes and radiographic outcomes of MOM-THA and MOP-THA. METHODS We performed a systematic review of English and non-English articles identified from MEDLINE, Embase, the Cochrane Central Register of Controlled Trials, PreMEDLINE and HealthSTAR. Metal ion concentrations, complications, reoperation rates and other outcomes of MOM bearings were compared with MOP bearings in THA based on relative risks, mean differences and standardized mean difference statistics. RESULTS Eight prospective randomized trials were identified from 1,075 citations. Our results demonstrated significantly elevated erythrocyte, serum and urine levels of metal ions (cobalt and chromium) among patients who received MOM-THA. No significant differences in titanium concentrations or total complication or reoperation rates were found between MOM-THA and MOP-THA. Clinical function scores and radiographic evaluations were similar between the two groups. CONCLUSIONS This analysis found insufficient evidence to identify any clinical advantage of MOM-THA compared with MOP-THA. Although cobalt and chromium concentrations were elevated after MOM-THA, there were no significant differences in total complication rates (including all-case mortality) between the two groups in the short- to mid-term follow-up period. The MOM bearing option for THA should be used with caution.
Collapse
Affiliation(s)
- Xinhua Qu
- Shanghai Key Laboratory of Orthopaedic Implant, Department of Orthopaedics, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai 200011, People's Republic of China
| | | | | |
Collapse
|
22
|
Cousen PJ, Gawkrodger DJ. Metal allergy and second-generation metal-on-metal arthroplasties. Contact Dermatitis 2011; 66:55-62. [DOI: 10.1111/j.1600-0536.2011.01970.x] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
23
|
Serum metal ion levels after rotating-hinge knee arthroplasty: comparison between a standard device and a megaprosthesis. INTERNATIONAL ORTHOPAEDICS 2011; 36:539-44. [PMID: 21755331 DOI: 10.1007/s00264-011-1317-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2011] [Accepted: 06/24/2011] [Indexed: 01/08/2023]
Abstract
PURPOSE The effects of systemic metal ion exposure in patients with implants made of common prosthetic alloys continue to be a matter of concern. The aim of the study was to determine the measurement values of cobalt (Co), chromium (Cr) and molybdenum (Mo) in serum following rotating-hinge knee arthroplasty. METHODS Blood was taken from 25 patients [mean follow-up 35 (range nine to 67) months] treated with megaprostheses (n=17) or standard rotating-hinge devices (n=8) and analysed using electrothermal graphite furnace atomic absorption spectrometry (ET-ASS). RESULTS Determining the concentrations of metal ions following rotating-hinge knee arthroplasty revealed increments for Co and Cr but not Mo. Metal ion release was significantly higher in patients with megaprostheses compared to a standard rotating-hinge knee device (Co p=0,024; Cr p=0.025). CONCLUSION The authors believe there might be an additional metal ion release from the surface of the prosthesis and not only from the articulating surfaces because, in cases of rotating-hinge knee prosthesis, there is a metal-on-polyethylene articulation and not a direct metal-on-metal junction. Nevertheless, long-term studies are required to determine adverse effects of Co, Cr and Mo following total hip replacement and total knee arthroplasty.
Collapse
|
24
|
Kim PR, Beaulé PE, Dunbar M, Lee JKL, Birkett N, Turner MC, Yenugadhati N, Armstrong V, Krewski D. Cobalt and chromium levels in blood and urine following hip resurfacing arthroplasty with the Conserve Plus implant. J Bone Joint Surg Am 2011; 93 Suppl 2:107-17. [PMID: 21543699 DOI: 10.2106/jbjs.j.01721] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The purpose of the present study was to determine cobalt and chromium ion levels in the blood and urine of patients in whom a modern-generation metal-on-metal hip resurfacing device had been implanted. METHODS A total of ninety-seven patients with a Conserve Plus metal-on-metal hip resurfacing implant were followed prospectively for two years. Cobalt and chromium levels in erythrocytes, serum, and urine were measured preoperatively as well as three, six, twelve, and twenty-four months postoperatively. RESULTS The median serum cobalt and chromium ion levels were 1.04 μg/L (range, 0.31 to 7.42 μg/L) and 2.00 μg/L (range, 0.28 to 10.49 μg/L), respectively, at one year after surgery and 1.08 μg/L (range, 0.44 to 7.13 μg/L) and 1.64 μg/L (range, 0.47 to 10.95 μg/L), respectively, at two years after surgery. The corresponding mean levels (and standard deviations) of serum cobalt and chromium were 1.68 ± 1.66 μg/L and 2.70 ± 2.22 μg/L, respectively, at one year after surgery and 1.79 ± 1.66 μg/L and 2.70 ± 2.37 μg/L, respectively, at two years after surgery. CONCLUSIONS These levels compare favorably with other published ion results for metal-on-metal hip resurfacing and replacement implants. No pseudotumors or other adverse soft-tissue reactions were encountered in our study population. Further research is needed to determine the clinical importance of increased cobalt and chromium ion levels in serum and urine following metal-on-metal hip resurfacing.
Collapse
Affiliation(s)
- Paul R Kim
- Division of Orthopedics, The Ottawa Hospital-General Campus, Room W1650, 501 Smyth Road, Ottawa, ON K1H 8L6, Canada.
| | | | | | | | | | | | | | | | | |
Collapse
|