1
|
Lips W, Sie CS, Freeman LM. Urinary retention during and after labor with programmed intermittent epidural bolus (PIEB) analgesia: a prospective observational study. Int J Obstet Anesth 2025; 61:104326. [PMID: 39827663 DOI: 10.1016/j.ijoa.2024.104326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2024] [Revised: 12/26/2024] [Accepted: 12/31/2024] [Indexed: 01/22/2025]
Abstract
BACKGROUND This study investigates the incidence and risk factors for urinary retention during and after labor in women receiving programmed intermittent epidural bolus (PIEB) analgesia and evaluates the optimal bladder management strategy. METHODS This prospective observational study assessed urinary retention during voiding attempts every two to three hours during labor and postpartum, among women with labor epidural analgesia using PIEB. Urinary retention was defined as a post-void residual volume >150 mL, determined by catheterization after spontaneous voiding. RESULTS Among 137 women included, with 277 voiding attempts during labor, the urinary retention rate was 20.6%, occurring in 48 women (35%). When the spontaneously voided volume was >50 mL, urinary retention was observed in less than 10% of attempts. Postpartum urinary retention occurred in nine women (6.7%) with a mean post-void residual volume of 1133 ± 447 mL; all were nulliparous, seven had induced labor, and five had an episiotomy. CONCLUSIONS Women who are able to successfully void during labor have a low risk of intrapartum urinary retention. We would recommend considering catheterization every 3 to 4 hours for women who are unable to urinate spontaneously, void less than 50 ml, or experience complete motor blockade during labor.
Collapse
Affiliation(s)
- Willemijn Lips
- Department of Obstetrics and Gynecology, Erasmus Medical Center, the Netherlands.
| | - Corina S Sie
- Department of Anesthesiology, Ikazia Hospital, the Netherlands.
| | - Liv M Freeman
- Department of Obstetrics and Gynecology, Ikazia Hospital, the Netherlands.
| |
Collapse
|
2
|
Ou CH, Chen WT. Programmed Intermittent Epidural Bolus Reduces Workloads in Labor Analgesia: A Single Center's Experience. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:993. [PMID: 38929610 PMCID: PMC11205856 DOI: 10.3390/medicina60060993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Revised: 05/30/2024] [Accepted: 06/14/2024] [Indexed: 06/28/2024]
Abstract
Background and Objectives: Labor epidural analgesia can be maintained through programmed intermittent epidural bolus (PIEB), continuous epidural infusion (CEI), or patient-controlled epidural analgesia (PCEA). Our department changed from CEI+PCEA to PIEB+PCEA as the maintenance method. The higher hourly dose setting in the current regimen brought to our concern that side effects would increase with proportional staff workloads. This study aimed to investigate the validity of our proposal that PIEB+PCEA may function as a feasible tool in reducing the amount of work in the obstetrics anesthesia units. Materials and methods: This 2-year retrospective review included parturients with vaginal deliveries under epidural analgesia. We compared the staff burden before and after the switch from CEI (6 mL/h, PCEA 6 mL lockout 15 min, group A) to PIEB (8 mL/h, PCEA 8 mL lockout 10 min, group B). The primary outcome was the difference of proportion of parturients requiring unscheduled visits between groups. Side effects and labor and neonatal outcomes were compared. Results: Of the 694 parturients analyzed, the proportion of those requiring unscheduled visits were significantly reduced in group B (20.8% vs. 27.7%, chi-square test, p = 0.033). The multivariate logistic regression showed that PIEB was associated with fewer unscheduled visits than CEI (OR = 0.53, 95% CI [0.36-0.80], p < 0.01). Group B exhibited a significantly lower incidence of asymmetric blockade, as well as motor blockade. In nulliparous subjects, obstetric anal sphincter injury occurred less frequently when PIEB+PCEA was used. Significantly more multiparous women experienced vacuum extraction delivery in group B than in group A, and they had a longer second stage of labor. Conclusions: The PIEB+PCEA protocol in our study reduced workloads in labor epidural analgesia as compared to CEI+PCEA, despite that a higher dose of analgesics was administered. Future studies are warranted to investigate the effect of manipulating the PIEB settings on the labor outcomes.
Collapse
Affiliation(s)
| | - Wei-Ting Chen
- Department of Anesthesiology, Shin Kong Memorial Wu Ho-Su Hospital, No. 95, Wen Chang Road, Shih Lin District, Taipei 111, Taiwan;
| |
Collapse
|
3
|
Howle R, Ragbourne S, Zolger D, Owolabi A, Onwochei D, Desai N. Influence of different volumes and frequency of programmed intermittent epidural bolus in labor on maternal and neonatal outcomes: A systematic review and network meta-analysis. J Clin Anesth 2024; 93:111364. [PMID: 38176084 DOI: 10.1016/j.jclinane.2023.111364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 12/11/2023] [Accepted: 12/14/2023] [Indexed: 01/06/2024]
Abstract
STUDY OBJECTIVE In labor, programmed intermittent epidural bolus (PIEB) can be defined as the bolus administration of epidural solution at scheduled time intervals. Compared to continuous epidural infusion (CEI) with or without patient controlled epidural analgesia (PCEA), PIEB has been associated with decreased pain scores and need for rescue analgesia and increased maternal satisfaction. The optimal volume and dosing interval of PIEB, however, has still not been determined. DESIGN Systematic review and network meta-analysis registered with PROSPERO (CRD42022362708). SETTINGS Labor. PATIENTS Pregnant patients. INTERVENTIONS Central, CINAHL, Global Health, Ovid Embase, Ovid Medline and Web of Science were searched for randomized controlled trials that examined pregnant patients in labor who received CEI or PIEB with or without a PCEA component. Network meta-analysis was performed with a frequentist method, facilitating the indirect comparison of PIEB with different volumes and dosing intervals through the common comparator of CEI and substituting or supplementing direct comparisons with these indirect ones. Continuous and dichotomous outcomes were presented as mean differences and odds ratios, respectively, with 95% confidence intervals. The risk of bias was evaluated using the Cochrane risk of bias 2 tool. MAIN RESULTS Overall, 30 trials were included. For the first primary endpoint, need for rescue analgesia, PIEB delivered at a volume of 4 ml and frequency of 45 min (4/45) was inferior to PIEB 8/45 (OR 3.55; 95% CI 1.12-11.33), PIEB 10/60 was superior to PIEB 2.5/15 (OR 0.36; 95% CI 0.16-0.82), PIEB 4/45 (OR 0.14; 95% CI 0.03-0.71) and PIEB 5/60 (OR 0.23; 95% CI 0.08-0.70), and PIEB 5/30 was not inferior to PIEB 10/60 (OR 0.61; 95% CI 0.31-1.19). For the second primary endpoint, maternal satisfaction, no differences were present between the various PIEB regimens. The quality of evidence for these multiple primary endpoints was low owing to the presence of serious limitations and imprecision. Importantly, PIEB 5/30 decreased the pain score at 4 h compared to PIEB 2.5/15 (MD 2.45; 95% CI 0.13-4.76), PIEB 5/60 (MD -2.28; 95% CI -4.18--0.38) and PIEB 10/60 (MD 1.73; 95% CI 0.31-3.16). Mean ranking of interventions demonstrated PIEB 10/60 followed by PIEB 5/30 to be best placed to reduce the cumulative dose of local anesthetic, and this resulted in an improved incidence of lower limb motor blockade for PIEB 10/60 in comparison to CEI (OR 0.30; 95% CI 0.14-0.67). No differences in neonatal outcomes were found. Some concerns were present for the risk of bias in two thirds of trials and the risk of bias was shown to be high in the remaining one third of trials. CONCLUSIONS Future research should focus on PIEB 5/30 and PIEB 10/60 and how the method of analgesia initiation, nature and concentration of local anesthetic, design of epidural catheter and rate of administration might influence outcomes related to the mother and neonate.
Collapse
Affiliation(s)
- Ryan Howle
- Department of Anaesthesia, Rotunda Hospital, Dublin, Ireland; Department of Anaesthesia, Mater Misericordiae University Hospital, Dublin, Ireland
| | - Sophie Ragbourne
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Danaja Zolger
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Adetokunbo Owolabi
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Desire Onwochei
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; King's College London, London, United Kingdom
| | - Neel Desai
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; King's College London, London, United Kingdom.
| |
Collapse
|
4
|
Ni F, Wu Z, Zhao P. Programmed intermittent epidural bolus in maintenance of epidural labor analgesia: a literature review. J Anesth 2023; 37:945-960. [PMID: 37733073 DOI: 10.1007/s00540-023-03253-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 08/29/2023] [Indexed: 09/22/2023]
Abstract
Programmed intermittent epidural bolus (PIEB), administered by the infusion pump programmed to deliver boluses of epidural solution at certain intervals, is gradually gaining more attention as a technique to maintain the labor analgesia in recent years. Many studies find that it may have some advantages when compared with other methods. However, its exact effectiveness and optimal regimen are still unclear. We conducted a literature search in PubMed, Web of Science, and Cochrane Database of Systematic Reviews for studies published between January 2010 and June 2022. Of the 263 publications identified, 27 studies were included. The purpose of this review is to discuss the effects of PIEB with continuous epidural infusion (CEI) and patient-controlled epidural analgesia (PCEA) in maintenance of epidural labor analgesia on labor outcomes and elucidate the latest research progress of implementation strategies.
Collapse
Affiliation(s)
- Fanshu Ni
- Department of Anesthesiology, Shengjing Hospital of China Medical University, No. 36 Sanhao Street Heping District, Shenyang, CN 110004, Liaoning Province, China
| | - Ziyi Wu
- Department of Anesthesiology, Shengjing Hospital of China Medical University, No. 36 Sanhao Street Heping District, Shenyang, CN 110004, Liaoning Province, China
| | - Ping Zhao
- Department of Anesthesiology, Shengjing Hospital of China Medical University, No. 36 Sanhao Street Heping District, Shenyang, CN 110004, Liaoning Province, China.
| |
Collapse
|
5
|
Tan HS, Zeng Y, Qi Y, Sultana R, Tan CW, Sia AT, Sng BL, Siddiqui FJ. Automated mandatory bolus versus basal infusion for maintenance of epidural analgesia in labour. Cochrane Database Syst Rev 2023; 6:CD011344. [PMID: 37276327 PMCID: PMC10240562 DOI: 10.1002/14651858.cd011344.pub3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
BACKGROUND Epidural analgesia is often used for pain relief during labour and childbirth, and involves administration of local anaesthetics (LA) into the epidural space resulting in sensory blockade of the abdomen, pelvis, and perineum. Epidural opioids are often co-administered to improve analgesia. Administration of epidural medications can be accomplished by basal infusion (BI) or automated mandatory bolus (AMB). With BI, medications are administered continuously, while AMB involves injecting medications at set time intervals. Patient-controlled epidural analgesia (PCEA) on top of AMB or BI enables patients to initiate additional boluses of epidural medications. The superior method of delivering epidural medications would result in lower incidence of pain requiring anaesthesiologist intervention (breakthrough pain). Also, it should be associated with lower incidence of epidural-related adverse effects including caesarean delivery, instrumental delivery (use of forceps or vacuum devices), prolonged duration of labour analgesia, and LA consumption. However, clear evidence of the superiority of one technique over the other is lacking. Also, differences in the initiation of epidural analgesia such as combined spinal-epidural (CSE) (medications given into the intrathecal space in addition to the epidural space) compared to epidural only, and medications used (types and doses of LA or opioids) may not have been accounted for in previous reviews. Our prior systematic review suggested that AMB reduces the incidence of breakthrough pain compared to BI with no significant difference in the incidence of caesarean delivery or instrumental delivery, duration of labour analgesia, and LA consumption. However, several studies comparing AMB and BI have been performed since then, and inclusion of their data may improve the precision of our effect estimates. OBJECTIVES To assess the benefits and harms of AMB versus BI for maintaining labour epidural analgesia in women at term. SEARCH METHODS We searched CENTRAL, Wiley Cochrane Library), MEDLINE, (National Library of Medicine), Embase(Elseiver), Web of Science (Clarivate), the WHO-ICTRP (World Health Organization) and ClinicalTrials.gov (National Library of Medicine) on 31 December 2022. Additionally, we screened the reference lists of relevant trials and reviews for eligible citations, and we contacted authors of included studies to identify unpublished research and ongoing trials. SELECTION CRITERIA We included all randomised controlled studies that compared bolus dosing AMB with continuous BI during epidural analgesia. We excluded studies of women in preterm labour, with multiple pregnancies, with fetal malposition, intrathecal catheters, those that did not use automated delivery of medications, and those where AMB and BI were combined. DATA COLLECTION AND ANALYSIS We used standard methodology for systematic review and meta-analysis described by Cochrane. Primary outcomes included: incidence of breakthrough pain requiring anaesthesiologist intervention; incidence of caesarean delivery; and incidence of instrumental delivery. Secondly, we assessed the duration of labour; hourly LA consumption in bupivacaine equivalents, maternal satisfaction after fetal delivery, and neonatal Apgar scores. The following subgroup analyses were chosen a priori: epidural alone versus CSE technique; regimens that used PCEA versus those that did not; and nulliparous versus combination of nulli- and multi-parous women. We used the GRADE system to assess the certainty of evidence associated with our outcome measures. MAIN RESULTS We included 18 studies of 4590 women, of which 13 enrolled healthy nulliparous women and five included healthy nulli- and multiparous women. All studies excluded women with preterm or complicated pregnancies. Techniques used to initiate epidural analgesia differed between the studies: seven used combined spinal epidural, 10 used epidural, and one used dural puncture epidural (DPE). There was also variation in analgesics used. Eight studies utilised ropivacaine with fentanyl, three used ropivacaine with sufentanil, two utilised levobupivacaine with sufentanil, one used levobupivacaine with fentanyl, and four utilised bupivacaine with fentanyl. Most of the studies were assessed to have low risk of randomisation, blinding, attrition, and reporting biases, except for allocation concealment where eight studies were assessed to have uncertain risk and three with high risk. Our results showed that AMB was associated with lower incidence of breakthrough pain compared to BI (risk ratio (RR) 0.71; 95% confidence interval (CI) 0.55 to 0.91; I2 = 57%) (16 studies, 1528 participants), and lower hourly LA consumption in bupivacaine equivalents (mean difference (MD) -0.84 mg/h; 95% CI -1.29 to -0.38, I2 = 87%) (16 studies, 1642 participants), both with moderate certainty. AMB was associated with an estimated reduction in breakthrough pain incidence of 29.1% (incidence 202 per 1000, 95% CI 157 to 259), and was therefore considered clinically significant. The incidence of caesarean delivery (RR 0.85; 95% CI 0.69 to 1.06; I2 = 0%) (16 studies, 1735 participants) and instrumental delivery (RR 0.85; 95% CI 0.71 to 1.01; I2 = 0%) (17 studies, 4550 participants) were not significantly, both with moderate certainty. There was no significant difference in duration of labour analgesia (MD -8.81 min; 95% CI -19.38 to 1.77; I2 = 50%) (17 studies, 4544 participants) with moderate certainty. Due to differences in the methods and timing of outcome measurements, we did not pool data for maternal satisfaction and Apgar scores. Results reported narratively suggest AMB may be associated with increased maternal satisfaction (eight studies reported increased satisfaction and six reported no difference), and all studies showed no difference in Apgar scores. WIth the exception of epidural alone versus CSE which found significant subgroup differences in LA consumption between AMB and BI, no significant differences were detected in the remaining subgroup analyses. AUTHORS' CONCLUSIONS Overall, AMB is associated with lower incidence of breakthrough pain, reduced LA consumption, and may improve maternal satisfaction. There were no significant differences between AMB and BI in the incidence of caesarean delivery, instrumental delivery, duration of labour analgesia, and Apgar scores. Larger studies assessing the incidence of caesarean and instrumental delivery are required.
Collapse
Affiliation(s)
- Hon Sen Tan
- Department of Women's Anaesthesia, KK Women's and Children's Hospital, Singapore, Singapore
| | - Yanzhi Zeng
- Department of Anaesthesiology, Singapore Health Services, Singapore, Singapore
| | - Yueyue Qi
- Duke-NUS Medical School, Singapore, Singapore
| | | | - Chin Wen Tan
- Department of Women's Anaesthesia, KK Women's and Children's Hospital, Singapore, Singapore
| | - Alex T Sia
- Department of Women's Anaesthesia, KK Women's and Children's Hospital, Singapore, Singapore
| | - Ban Leong Sng
- Department of Women's Anaesthesia, KK Women's and Children's Hospital, Singapore, Singapore
| | - Fahad J Siddiqui
- Duke-NUS Medical School, National University Singapore, Singapore, Singapore
| |
Collapse
|
6
|
Wydall S, Zolger D, Owolabi A, Nzekwu B, Onwochei D, Desai N. Comparison of different delivery modalities of epidural analgesia and intravenous analgesia in labour: a systematic review and network meta-analysis. Can J Anaesth 2023; 70:406-442. [PMID: 36720838 DOI: 10.1007/s12630-022-02389-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2022] [Revised: 09/15/2022] [Accepted: 09/16/2022] [Indexed: 02/02/2023] Open
Abstract
PURPOSE In labour, neuraxial analgesia is the standard in the provision of pain relief. However, the optimal mode of delivering epidural solution has not been determined, and some parturients may need an alternative to epidural analgesia. We sought to conduct a systematic review and network meta-analysis to compare continuous epidural infusion (CEI), programmed intermittent epidural bolus (PIEB), computer-integrated CEI, computer-integrated PIEB, patient-controlled epidural bolus (PCEA), fentanyl patient-controlled analgesia (PCA), and remifentanil PCA, either alone or in combination. METHODS We searched CENTRAL, CINAHL, Ovid Embase, Ovid Medline, and Web of Science for randomized controlled trials that included nulliparous and/or multiparous parturients in spontaneous or induced labour. The maintenance epidural solution had to include a low concentration local anesthetic and an opioid. Specific subgroups in the obstetric population such as preeclampsia were excluded. Network meta-analysis was performed with a frequentist method, and continuous and dichotomous outcomes are presented as mean differences and odds ratios, respectively, with 95% confidence intervals. RESULTS Overall, 73 trials were included. For the first coprimary outcome, the need for rescue analgesia, CEI was inferior to PIEB and PIEB + PCEA was superior to PCEA alone, with a low certainty of evidence given the presence of serious limitations and imprecision. The second coprimary outcome, the maternal satisfaction, was improved by PIEB + PCEA compared with CEI + PCEA and PCEA alone, with a low quality of evidence in view of the presence of serious limitations and imprecision. Fentanyl PCA increased the requirement for rescue analgesia and decreased maternal satisfaction relative to many methods of delivering epidural solution. In terms of secondary outcomes, PIEB increased analgesic efficacy compared with CEI, and PCEA reduced local anesthetic consumption at the expense of inferior analgesia relative to CEI and PIEB. PIEB + PCEA was superior to CEI + PCEA in regard to the pain score at 2 h and 4 h, consumption of local anesthetic, incidence of lower lower limb motor blockade and the rate of spontaneous vaginal delivery. Fentanyl and remifentanil PCA did not provide the same level of analgesia as all epidural methods, resulted in increasing analgesic ineffectiveness with time spent in labour, and predisposed to a higher incidence of side effects such as nausea and/or vomiting and sedation. Remifentanil PCA was superior to fentanyl PCA for analgesia at an early time point, and it increased the incidence of oxygen desaturation relative to other strategies of delivering epidural solution. CONCLUSIONS Opioid PCA did not provide the same level of analgesia as epidural methods with a higher incidence of side effects. We interpret the findings of our systematic review and network meta-analysis as suggesting PIEB + PCEA to be the optimal delivery mode of epidural solution. Nevertheless, the potential differing importance of the various maternal, fetal, and neonatal outcomes in determining which is optimal has not, to our knowledge, been elucidated yet. STUDY REGISTRATION PROSPERO (CRD42021254978); registered 27 May 2021.
Collapse
Affiliation(s)
- Simon Wydall
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, St Thomas' Hospital, Westminster Bridge Road, London, SE1 7EH, UK.
| | - Danaja Zolger
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, London, UK
| | - Adetokunbo Owolabi
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, London, UK
| | - Bernadette Nzekwu
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, London, UK
| | - Desire Onwochei
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, London, UK
- King's College London, London, UK
| | - Neel Desai
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, London, UK
- King's College London, London, UK
| |
Collapse
|
7
|
Optimum programmed intermittent epidural bolus interval time between 8 mL boluses of Ropivacaine 0.1% with sufentanil 0.3 μg/mL with dural puncture epidural technique for labor analgesia: A biased-coin up-and-down sequential allocation trial. J Clin Anesth 2022; 79:110698. [DOI: 10.1016/j.jclinane.2022.110698] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Revised: 02/20/2022] [Accepted: 02/22/2022] [Indexed: 11/21/2022]
|
8
|
Wang L, Liu H, Duan Y, Cheng Q, Feng S. Analgesic Effects of Epidural Labor Analgesia at Different Periods and Its Effects on Maternal and Infant Outcomes and MiRNA-146b Level. JOURNAL OF HEALTHCARE ENGINEERING 2021; 2021:2879678. [PMID: 34868513 PMCID: PMC8639244 DOI: 10.1155/2021/2879678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Revised: 11/08/2021] [Accepted: 11/09/2021] [Indexed: 11/17/2022]
Abstract
This paper aimed to analyze the analgesic effects of continuous epidural labor analgesia (ELA) at different periods and its effects on postpartum depression, maternal and infant outcomes, and maternal blood pressure. Giving birth in our hospital from September 2017 to August 2019, 119 primiparas with spontaneous delivery were enrolled and divided into an observation group (65 cases) and a control group (54 cases). Patients in the observation group received epidural block analgesia in advance, whereas those in the control group received epidural block analgesia routinely. At 25 days after delivery, breast milk samples were collected, in which miRNA-146b level was detected by PCR. The patients were compared between the two groups with respect to progress of labor, analgesic effects during 3 stages of labor, labor outcomes, adverse reactions, and levels of NO, ANP, and ET-1 in the parturients' umbilical artery blood. Compared with those in the control group, patients in the observation group had a remarkably higher miRNA-146b level in the breast milk (P < 0.05), remarkably lower average Visual Analogue Scale (VAS) scores during the active phase and the second stage of labor (P < 0.05), and remarkably higher levels of NO, ANP, and ET-1 (P < 0.05). There were no statistically significant differences in adverse reactions and modes of delivery between the two groups (P < 0.05). ELA starting from the latent phase can improve the miRNA-146b level in maternal breast milk, alleviate labor pain of parturients, and shorten stages of labor. Therefore, our study is worthy of clinical promotion. We still need to do more experiments and use more data to conclude more scientific results in future research work.
Collapse
Affiliation(s)
- Lihong Wang
- Department of Anesthesiology, Chifeng Obstetrics and Gynecology Hospital, Chifeng 024000, Inner Mongolia, China
| | - Hui Liu
- Department of Anesthesiology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot 010010, Inner Mongolia, China
| | - Ye Duan
- Department of Anesthesiology, Chifeng Obstetrics and Gynecology Hospital, Chifeng 024000, Inner Mongolia, China
| | - Qingyu Cheng
- Department of Anesthesiology, Chifeng Obstetrics and Gynecology Hospital, Chifeng 024000, Inner Mongolia, China
| | - Suhua Feng
- Department of Anesthesiology, Chifeng Obstetrics and Gynecology Hospital, Chifeng 024000, Inner Mongolia, China
| |
Collapse
|
9
|
Rinaldi L, Ghirardini AM, Troglio R, Bellini V, Donno L, Biondini S, Biagioni E, Baciarello M, Bignami E, Girardis M. Pain management during labor: use of intermittent drug delivery devices for improvement of obstetric and neonatal outcome and reduction of healthcare burden: A large non-inferiority randomized clinical trial. JOURNAL OF ANESTHESIA, ANALGESIA AND CRITICAL CARE (ONLINE) 2021; 1:2. [PMID: 37386624 DOI: 10.1186/s44158-021-00003-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/01/2023]
Abstract
BACKGROUND Automated continuous epidural administration of local anesthetics provides a more stable analgesic block with decreasing of healthcare staff compared to manual boluses administration (TOP-UP) but is associated to high rate of operative vaginal delivery. We hypothesized that the use of programmed intermittent automated boluses (PIEB) is able to provide a good quality of analgesia and decreasing of anesthesiologic workload without increasing the rate of instrumental vaginal birth in comparison with TOP-UP technique. Laboring nulliparous woman aged between 18 and 46 years were randomized to epidural analgesia with 0.0625% levobupivacaine and sufentanil administered by PIEB or by TOP-UP techniques. Primary outcome was instrumental vaginal delivery rate and secondary outcomes were quality of analgesia, total and time-related drugs doses used, motor block, newborn outcome, and anesthesiologic workload. RESULTS Six hundred twenty-nine were randomized, and 628 were included in the intention-to-treat analysis. The rate of instrumental vaginal delivery was similar in the PIEB and TOP-UP groups (13.2% vs 9.7%, OR 1.4 95% CI 0.8 to 2.5; p 0.21). There was no difference between groups regarding mode of delivery (cesarean section vs vaginal birth), newborn outcome, and motor block. Patients in the PIEB group received more total and time-related drugs doses and a better quality of analgesia. Anesthesiological workload was significantly reduced in the PIEB group. CONCLUSIONS Our study demonstrated that epidural anesthesia with programmed intermittent epidural boluses by an automated device provides an effective and safe management of labor analgesia with improvement of pain control and sparing of man workload compared to manual top-up protocols.
Collapse
Affiliation(s)
- Laura Rinaldi
- Anesthesia and Intensive Care Unit, University Hospital of Modena, L.go del Pozzo 71, 41125, Modena, Italy.
| | - Anna Maria Ghirardini
- Anesthesia and Intensive Care Unit, University Hospital of Modena, L.go del Pozzo 71, 41125, Modena, Italy
| | - Raffaella Troglio
- Anesthesiology and Critical Care Division, Department of Medicine and Surgery, University of Parma, Viale Gramsci 14, 43126, Parma, Italy
| | - Valentina Bellini
- Anesthesiology and Critical Care Division, Department of Medicine and Surgery, University of Parma, Viale Gramsci 14, 43126, Parma, Italy
| | - Lara Donno
- Anesthesia and Intensive Care Unit, University Hospital of Modena, L.go del Pozzo 71, 41125, Modena, Italy
| | - Susanna Biondini
- Anesthesiology and Critical Care Division, Department of Medicine and Surgery, University of Parma, Viale Gramsci 14, 43126, Parma, Italy
| | - Emanuela Biagioni
- Anesthesia and Intensive Care Unit, University Hospital of Modena, L.go del Pozzo 71, 41125, Modena, Italy
| | - Marco Baciarello
- Anesthesiology and Critical Care Division, Department of Medicine and Surgery, University of Parma, Viale Gramsci 14, 43126, Parma, Italy
| | - Elena Bignami
- Anesthesiology and Critical Care Division, Department of Medicine and Surgery, University of Parma, Viale Gramsci 14, 43126, Parma, Italy
| | - Massimo Girardis
- Anesthesia and Intensive Care Unit, University Hospital of Modena, L.go del Pozzo 71, 41125, Modena, Italy
| |
Collapse
|
10
|
Song Y, Du W, Zhou S, Zhou Y, Yu Y, Xu Z, Liu Z. Effect of Dural Puncture Epidural Technique Combined With Programmed Intermittent Epidural Bolus on Labor Analgesia Onset and Maintenance: A Randomized Controlled Trial. Anesth Analg 2021; 132:971-978. [PMID: 32282386 DOI: 10.1213/ane.0000000000004768] [Citation(s) in RCA: 56] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
BACKGROUND The dural puncture epidural (DPE) technique is associated with faster onset than the conventional epidural (EP) technique for labor analgesia. The programmed intermittent epidural bolus (PIEB) mode for maintaining labor analgesia allows for lower anesthetic drug consumption than the continuous epidural infusion (CEI) mode. Whether DPE technique with PIEB mode offers additional benefits for analgesia onset, local anesthetic drug consumption, and side effects versus EP or DPE techniques with CEI mode remains unclear. METHODS Nulliparous women with a visual analog scale (VAS) pain score >50 mm and cervical dilation <5 cm were randomly assigned to receive EP + CEI, DPE + CEI, or DPE + PIEB for labor analgesia. A 25-gauge needle was used for dural puncture. Analgesia was initiated with 10 mL of 0.1% ropivacaine with 0.3 µg/mL of sufentanil and maintained with the same solution at 8 mL/h in all groups. A 5-mL patient-controlled epidural analgesia (PCEA) bolus was programmed with a 20-minute lockout. Breakthrough pain not amendable by PCEA was treated with provider boluses of 5 mL of 0.125% ropivacaine. The primary outcome was "time to adequate analgesia," defined as a VAS pain score ≤30 mm during 2 consecutive contractions, and was analyzed using Kaplan-Meier curves and a Cox proportional hazard model. Secondary outcomes included the VAS scores, ropivacaine consumption, sensory block level to ice, PCEA and provider boluses intervention, mode of delivery, duration of labor, Bromage scores, Apgar scores, occurrence of side effects, and maternal satisfaction with the anesthesia. RESULTS A total of 116 women were included (38 in the EP + CEI group, 40 in the DPE + CEI group, and 38 in the DPE + PIEB group). Adequate anesthesia was achieved faster in the DPE + CEI and DPE + PIEB groups than in the EP + CEI group (hazard ratio = 1.705; 95% confidence interval [CI], 1.039-2.800; P = .015; and hazard ratio = 1.774; 95% CI, 1.070-2.941; P = .012, respectively). DPE technique with PIEB mode was associated with the fewest PCEA boluses and the lowest hourly ropivacaine consumption (both P < .001). There were no differences in the duration of labor, mode of delivery, Bromage scores, newborn Apgar scores, incidence of side effects, and maternal satisfaction scores among the groups. CONCLUSIONS The use of DPE technique for neuraxial analgesia was associated with faster onset than the use of the EP technique. DPE technique with PIEB mode achieved the greatest drug-sparing effect without increasing maternal or neonatal side effects.
Collapse
Affiliation(s)
- Yujie Song
- From the Department of Anesthesiology, Shanghai First Maternity and Infant Hospital, Tongji University School of Medicine, Shanghai, China
| | | | | | | | | | | | | |
Collapse
|
11
|
Holgado CM, Girones A, Tapia N, De Molina-Fernandez MI, Anez C. Labor outcomes with epidural analgesia: an observational before-and-after cohort study comparing continuous infusion versus programmed intermittent bolus plus patient-controlled analgesia. Minerva Anestesiol 2020; 86:1277-1286. [PMID: 33174403 DOI: 10.23736/s0375-9393.20.14516-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Scientific evidence shows that programmed intermittent epidural bolus (PIEB) for labor analgesia achieves good obstetric outcomes. After implementing our institutional standard for epidural analgesia, we compared PIEB + patient-controlled epidural analgesia (PCEA) versus continuous epidural infusion (CEI). METHODS In an observational cohort study, we compared CEI with 0.2% ropivacaine + 100-μg fentanyl initial bolus versus PIEB+PCEA with 0.1% ropivacaine + 2 μg mL-1 fentanyl in primiparous women. The primary outcome was mode of delivery. Secondary outcomes were duration of the second stage of labor and total ropivacaine and fentanyl doses. Other outcomes, in the PIEB+PCEA group only, were motor block, use of PCEA and rescue bolus, maternal mobility and maternal satisfaction. Univariate statistical analysis was performed using the χ2 Test, analysis of variance or nonparametric Kruskal-Wallis Test. Multivariate analysis was performed using multiple logistic regression analysis. RESULTS The study included 221 patients (CEI 116; PIEB+PCEA 105). Multiple logistic regression showed that the PIEB+PCEA group had significantly fewer caesarean sections (CEI [14%] vs. PIEB+PCEA [5%], P=0.015) and instrumental deliveries, after correcting for confounders (OR=0.49; 95% CI: 0.27-0.89). The second stage of labor did not significantly differ between groups. Total ropivacaine dose was significantly lower with PIEB+PCEA. There was no relationship between mild motor block and increased use of PCEA in the PIEB+PCEA group. Mode of delivery and duration of the second stage of labor were not influenced by motor block either. Maternal satisfaction was high. CONCLUSIONS PIEB+PCEA offers obstetric and analgesic advantages over CEI in daily clinical practice.
Collapse
Affiliation(s)
- Carmen M Holgado
- Department of Anesthesia, Critical Care and Pain Medicine, Joan XXIII University Hospital, Tarragona, Spain - .,Department of Medicine and Surgery, ANESTARRACO (IISPV) Research Group, Rovira i Virgili University, Tarragona, Spain -
| | - Aitana Girones
- Department of Anesthesia, Critical Care and Pain Medicine, Joan XXIII University Hospital, Tarragona, Spain
| | - Nuria Tapia
- Department of Anesthesia, Critical Care and Pain Medicine, Sant Pau i Santa Tecla Hospital, Terragona, Spain
| | | | - Cristobal Anez
- Department of Anesthesia, Critical Care and Pain Medicine, Joan XXIII University Hospital, Tarragona, Spain.,Department of Medicine and Surgery, ANESTARRACO (IISPV) Research Group, Rovira i Virgili University, Tarragona, Spain
| |
Collapse
|
12
|
Hussain N, Lagnese CM, Hayes B, Kumar N, Weaver TE, Essandoh MK, Reno J, Small RH, Abdallah FW. Comparative analgesic efficacy and safety of intermittent local anaesthetic epidural bolus for labour: a systematic review and meta-analysis. Br J Anaesth 2020; 125:560-579. [PMID: 32703549 DOI: 10.1016/j.bja.2020.05.060] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2020] [Revised: 04/14/2020] [Accepted: 05/08/2020] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND Continuous epidural infusion (CEI) is commonly used for labour analgesia, but concerns over potential motor block, second-stage labour complications, and ineffective analgesia in late labour have prompted examining intermittent epidural bolus (IEB) as an alternative. However, evidence comparing these modalities is conflicting. The meta-analysis evaluates the analgesic efficacy of CEI vs IEB. METHODS Databases were searched for trials comparing CEI to IEB for labour analgesia. The two co-primary outcomes were risk of breakthrough pain and difference in area under the curve (AUC) for pain scores during the first 4 h post-epidural initiation. Local anaesthetic consumption, maternal outcomes (i.e. delivery mode, labour duration, and maternal satisfaction), and side-effects of epidural analgesia were also evaluated. Results were pooled using random-effects modelling. Trial sequential analysis (TSA) was used to evaluate evidence reliability. RESULTS Twenty-seven studies (3133 patients) were analysed. Compared with CEI, IEB decreased risk of breakthrough pain by 38% (risk ratio [95% confidence interval {CI}] of 0.62 [0.48, 0.81]; P=0.0004; I2=47%; 1164 patients) and reduced AUC of pain during the 4 h interval by 32.9% (mean difference [95% CI] of -16.7 mm h-1 [-18.9, -14.4]; P<0.0001; 1638 patients). Intermittent epidural bolus enhanced maternal satisfaction, shortened labour duration, decreased motor block, and reduced local anaesthetic consumption. The difference between the two groups was not statistically significant for epidural side-effects or mode of delivery. The TSA indicated adequate power for reliable inferences. CONCLUSIONS Intermittent epidural bolus provides improved labour pain control during the first 4 h after epidural initiation with less breakthrough pain. Moderate- to high-quality evidence of intermittent epidural bolus superiority support its use as a safe and effective continuous epidural infusion alternative for labour analgesia.
Collapse
Affiliation(s)
- Nasir Hussain
- Department of Anesthesiology, Ohio State University, Wexner Medical Center, Columbus, OH, USA
| | - Christopher M Lagnese
- Department of Anesthesiology, Ohio State University, Wexner Medical Center, Columbus, OH, USA
| | - Blair Hayes
- Department of Anesthesiology, Ohio State University, Wexner Medical Center, Columbus, OH, USA
| | - Nicolas Kumar
- Department of Anesthesiology, Ohio State University, Wexner Medical Center, Columbus, OH, USA
| | - Tristan E Weaver
- Department of Anesthesiology, Ohio State University, Wexner Medical Center, Columbus, OH, USA
| | - Michael K Essandoh
- Department of Anesthesiology, Ohio State University, Wexner Medical Center, Columbus, OH, USA
| | - Joseph Reno
- Department of Anesthesiology, Ohio State University, Wexner Medical Center, Columbus, OH, USA
| | - Robert H Small
- Department of Anesthesiology, Ohio State University, Wexner Medical Center, Columbus, OH, USA
| | - Faraj W Abdallah
- Department of Anesthesiology and Pain Medicine, University of Ottawa, Ottawa, ON, Canada; The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON, Canada; The Li Ka Shing Knowledge Institute, St Michael's Hospital, University of Toronto, Toronto, ON, Canada; Department of Anesthesiology and Pain Medicine, North York General Hospital, University of Toronto, ON, Canada.
| |
Collapse
|
13
|
Does programmed intermittent epidural bolus improve childbirth conditions of nulliparous women compared with patient-controlled epidural analgesia?: A multicentre, randomised, controlled, triple-blind study. Eur J Anaesthesiol 2020; 36:755-762. [PMID: 31335447 DOI: 10.1097/eja.0000000000001053] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Epidural analgesia may change the mechanics of childbirth. These changes are related to the concentration of the local anaesthetic used epidurally but probably also to its mode of delivery into the epidural space. OBJECTIVE To determine whether the administration of programmed intermittent epidural boluses (PIEB) improves the mechanics of second-stage labour compared with patient-controlled epidural analgesia (PCEA) with a background infusion. DESIGN A randomised, controlled, triple-blind study. SETTING Multicentre study including four level III maternity units, January 2014 until June 2016. PATIENTS A total of 298 nulliparous patients in spontaneous labour were randomised to a PIEB or PCEA group. INTERVENTION After epidural initiation with 15 ml of 0.1% levobupivacaine containing 10 μg of sufentanil, patients received either an hourly bolus of 8 ml (PIEB) or a continuous rate infusion of 8 ml h (PCEA): the drug mixture used was levobupivacaine 0.1% and sufentanil 0.36 μg ml. MAIN OUTCOME MEASURES The primary outcome was a composite endpoint of objective labour events: a posterior occiput position in the second stage, an occiput position at birth, waiting time at full cervical dilatation before active maternal pushing more than 3 h, maternal active pushing duration more than 40 min, and foetal heart rate alterations. Vaginal instrumental delivery rates, analgesia and motor blockade scores were also recorded. RESULTS From the 298 patients randomised, data from 249 (124 PIEB, 125 PCEA) were analysed. No difference was found in the primary outcome: 48.0% (PIEB) and 45.5% (PCEA) of patients, P = 0.70. In addition, no difference was observed between the groups for each of the individual events of the composite endpoint, nor in the instrumental vaginal delivery rate, nor in the degree of motor blockade. Despite an equivalent volume of medication in the groups, a significantly higher analgesia score at full dilatation was observed in the PIEB group, odds-ratio = 1.9 (95% confidence interval, 1.0 to 3.5), P = 0.04. CONCLUSION The mechanics of the second stage did not differ whether PIEB or PCEA was used. Analgesic conditions appeared to be superior with PIEB, especially at full dilation. TRIAL REGISTRATION NCT01856166.
Collapse
|
14
|
Ojo OA, Mehdiratta JE, Gamez BH, Hunting J, Habib AS. Comparison of Programmed Intermittent Epidural Boluses With Continuous Epidural Infusion for the Maintenance of Labor Analgesia: A Randomized, Controlled, Double-Blind Study. Anesth Analg 2020; 130:426-435. [PMID: 30882524 DOI: 10.1213/ane.0000000000004104] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND Programmed intermittent epidural boluses may improve the spread of local anesthetics compared to continuous epidural infusion, improving labor analgesia and obstetric outcomes. However, there are limited data from studies using commercially available pumps capable of coadministering programmed intermittent epidural boluses or continuous epidural infusion with patient-controlled epidural analgesia. Therefore, we performed this prospective, randomized, double-blind study to compare the impact of programmed intermittent epidural boluses versus continuous epidural infusion on labor analgesia and maternal/neonatal outcomes. We hypothesized that programmed intermittent epidural boluses will result in lower patient-controlled epidural analgesia consumption compared to that with continuous epidural infusion. METHODS Following standardized initiation of epidural labor analgesia, women were randomized to receive 0.1% ropivacaine with 2 µg/mL fentanyl as 6-mL programmed intermittent epidural boluses every 45 minutes or continuous epidural infusion at 8 mL/h in a double-blind fashion with similar patient-controlled epidural analgesia settings in both groups. The primary outcome was patient-controlled epidural analgesia consumption per hour. Secondary outcomes included a need for physician interventions, patterns of patient-controlled epidural analgesia use, motor blockade, number of patients who developed hypotension, pain scores, duration of second stage of labor, mode of delivery, and maternal satisfaction. RESULTS We included 120 patients (61 in programmed intermittent epidural boluses group and 59 in continuous epidural infusion group) in the analysis. The median (interquartile range) patient-controlled epidural analgesia volume consumed per hour was not significantly different between the groups: 4.5 mL/h (3.0-8.6 mL/h) for the continuous epidural infusion group and 4.0 mL/h (2.2-7.1 mL/h) for the programmed intermittent epidural boluses group (P = .17). The Hodges-Lehmann location shift estimate of the difference (95% CI) from the continuous epidural infusion to the programmed intermittent epidural boluses group is 0.9 mL/h (-0.4 to 2.2 mL/h). There were also no significant differences between the groups in any of the secondary outcomes except for higher median (interquartile range) patient-controlled epidural analgesia attempts per given ratio per hour in the programmed intermittent epidural bolus group (0.17 [0.10-0.30] vs 0.12 [0.08-0.18]; P = .03) and more motor block in the continuous epidural infusion group (those with Bromage score <5, 27.5% vs 50.0%; P = .03). CONCLUSIONS Under the conditions of our study, we did not find improved outcomes with programmed intermittent epidural boluses compared to continuous epidural infusion except for less motor block with programmed intermittent epidural boluses. Future studies should assess whether smaller but clinically important differences exist and evaluate different parameters of programmed intermittent epidural boluses to optimize analgesia and outcomes with this mode of analgesia.
Collapse
Affiliation(s)
- Oluremi A Ojo
- From the Department of Anesthesiology, Duke University, Durham, North Carolina
| | | | | | | | | |
Collapse
|
15
|
Lee B, Lee JH, Kim MS, Kim SJ, Song J, Kim DH, Choi YS. Epidural bolus versus continuous epidural infusion analgesia on optic nerve sheath diameter in paediatric patients: A prospective, double-blind, randomised trial. Sci Rep 2020; 10:5477. [PMID: 32214139 PMCID: PMC7096447 DOI: 10.1038/s41598-020-62273-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Accepted: 03/11/2020] [Indexed: 11/24/2022] Open
Abstract
The use of programmed intermittent epidural bolus for postoperative analgesia may have greater analgesic efficacy than continuous epidural infusion. However, the rapid delivery speed used with an epidural bolus is more likely to increase intracranial pressure. We compared the effects of lumbar epidural bolus versus continuous infusion epidural analgesia on intracranial pressure in children using optic nerve sheath diameter as a marker. We randomly assigned 40 paediatric patients to bolus or infusion groups. Epidural analgesia (0.15% ropivacaine 0.3 ml·kg−1) was administered via bolus or infusion. Ultrasonography was used to measure the optic nerve sheath diameter before (T0), at 3 min (T1), 10 min (T2), and 70 min (T3) after starting the pump. There were statistically significant between-group differences in optic nerve sheath diameter over time (PGroup x Time = 0.045). From T0–T3, the area under the curve values were similar between the two groups. Although there were differences in the patterns of optic nerve sheath diameter change according to the delivery mode, the use of lumbar epidural bolus did not increase the risk of intracranial pressure increase over that of continuous infusion. Further research is needed to investigate intracranial pressure changes after continuous application of each delivery mode.
Collapse
Affiliation(s)
- Bora Lee
- Department of Anaesthesiology and Pain Medicine, Severance Hospital and Anaesthesia and Pain Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-Gu, Seoul, 03722, Republic of Korea
| | - Jae Hoon Lee
- Department of Anaesthesiology and Pain Medicine, Severance Hospital and Anaesthesia and Pain Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-Gu, Seoul, 03722, Republic of Korea
| | - Min-Soo Kim
- Department of Anaesthesiology and Pain Medicine, Severance Hospital and Anaesthesia and Pain Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-Gu, Seoul, 03722, Republic of Korea
| | - Seon Ju Kim
- Department of Anaesthesiology and Pain Medicine, Severance Hospital and Anaesthesia and Pain Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-Gu, Seoul, 03722, Republic of Korea
| | - Jeehyun Song
- Department of Anaesthesiology and Pain Medicine, Severance Hospital and Anaesthesia and Pain Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-Gu, Seoul, 03722, Republic of Korea
| | - Do-Hyeong Kim
- Department of Anaesthesiology and Pain Medicine, Anaesthesia and Pain Research Institute, Gangnam Severance Hospital, Yonsei University College of Medicine, 211 Eonju-ro, Gangnam-gu, Seoul, 06273, Republic of Korea
| | - Yong Seon Choi
- Department of Anaesthesiology and Pain Medicine, Severance Hospital and Anaesthesia and Pain Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-Gu, Seoul, 03722, Republic of Korea.
| |
Collapse
|
16
|
Optimum interval time of programmed intermittent epidural bolus of ropivacaine 0.08% with sufentanyl 0.3 μg/mL for labor analgesia: a biased-coin up-and-down sequential allocation trial. Chin Med J (Engl) 2020; 133:517-522. [PMID: 32142491 PMCID: PMC7065850 DOI: 10.1097/cm9.0000000000000669] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
BACKGROUND The programmed intermittent epidural bolus (PIEB) technique is widely used in labor analgesia, but the parameter settings of PIEB have not yet been standardized. We designed a study to identify the optimal interval duration for PIEB using 10 mL of ropivacaine 0.08% and sufentanyl 0.3 μg/mL, a regimen commonly used to control labor pain in China, to provide effective analgesia in 90% of women during the first stage of labor without breakthrough pain. METHODS We conducted a double-blind sequential allocation trial to obtain the effective interval 90% (EI90%) during the first stage of labor between April 2019 and May 2019. This study included the American Society of Anesthesiologists physical status II-III nulliparous parturients at term, who requested epidural analgesia. The bolus volume was fixed at 10 mL of ropivacaine 0.08% with sufentanyl 0.3 μg/mL. Participants were divided into four groups (groups 60, 50, 40, and 30) according to the PIEB intervals (60, 50, 40, and 30 min, respectively). The interval duration of the first parturient was set at 60 min and that of subsequent parturients varied according to a biased-coin design. The truncated Dixon and Mood method and the isotonic regression analysis method were used to estimate the EI90% and its 95% confidence intervals (CIs). RESULTS Forty-four women were enrolled in this study. The estimated optimal interval was 44.1 min (95% CI 41.7-46.5 min) and 39.5 min (95% CI 32.5-50.0 min), using the truncated Dixon and Mood method and isotonic regression analysis, respectively. The maximum sensory block level above T6 was in nearly 20% of parturients in group 30; however, 5.3%, 0%, and 0% of the parturients presented with sensory block level above T6 in groups 40, 50, and 60, respectively. There were no cases of hypotension and only one parturient complained of motor block. CONCLUSION With a fixed 10 mL dose of ropivacaine 0.08% with sufentanyl 0.3 μg/mL, the optimal PIEB interval is about 42 min. Further studies are warranted to define the efficacy of this regimen throughout all stages of labor. TRIAL REGISTRATION Chinese Clinical Trial Registry, ChiCTR1900022199; http://www.chictr.org.cn/com/25/historyversionpuben.aspx?regno=ChiCTR1900022199.
Collapse
|
17
|
Diez-Picazo LD, Guasch E, Brogly N, Gilsanz F. Is breakthrough pain better managed by adding programmed intermittent epidural bolus to a background infusion during labor epidural analgesia? A randomized controlled trial. Minerva Anestesiol 2019; 85:1097-1104. [PMID: 31213040 DOI: 10.23736/s0375-9393.19.13470-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Breakthrough pain (BTP) is a common problem during labor analgesia. Programmed intermittent epidural bolus (PIEB) has demonstrated superior to background epidural infusion (BEI) concerning BTP, but the effect of combining both modes remains unknown. We hypothesized that this combination could reduce BTP incidence. METHODS Nulliparous parturients with early cervical dilation were randomized to receive 5 mL/h BEI of levobupivacaine 0.125% plus fentanyl 1.45 µg/mL (standard group) or 5 mL/h BEI + 10 mL/h PIEB (PIEB group). In case of BTP, patient-controlled epidural analgesia (PCEA) boluses of 10 mL (20-min lockout interval) were administered. If PCEA was insufficient, a 10-mL clinician bolus was delivered. The primary endpoint was the percentage of parturients who required supplementary epidural boluses. RESULTS One hundred and twenty women were recruited. Eighty-nine percent of parturients required supplementary boluses in standard group versus 30% in PIEB group (RR=3.07; 95% CI: 1.99-4.76; P<0.001). Adding PIEB prevented BTP in 70% of cases. Duration of effective analgesia was longer in PIEB than in standard group (P=0.003). Supplementary boluses were decreased (P<0.001), while local anesthetic consumption increased (P<0.001) by PIEB addition. Sensory-motor block, mode of delivery, maternal satisfaction and neonatal outcomes were equally distributed in both groups. CONCLUSIONS Adding PIEB to BEI+PCEA improved labor analgesia by significantly reducing the needs of rescue analgesia and prolonging the duration of effective analgesia. This combination provoked a higher consumption of local anesthetic with no detected clinical consequences.
Collapse
Affiliation(s)
- Luis D Diez-Picazo
- Department of Anesthesia, Critical Care and Pain Treatment, La Paz University Hospital, Madrid, Spain -
| | - Emilia Guasch
- Department of Anesthesia, Critical Care and Pain Treatment, La Paz University Hospital, Madrid, Spain
| | - Nicolas Brogly
- Department of Anesthesia, Critical Care and Pain Treatment, La Paz University Hospital, Madrid, Spain
| | - Fernando Gilsanz
- Department of Anesthesia, Critical Care and Pain Treatment, La Paz University Hospital, Madrid, Spain
| |
Collapse
|
18
|
Kendall MC. Efficacy of aromatherapy to reduce labor pain. Arch Gynecol Obstet 2018; 298:453. [PMID: 29938345 DOI: 10.1007/s00404-018-4831-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2018] [Accepted: 06/18/2018] [Indexed: 12/01/2022]
Affiliation(s)
- Mark C Kendall
- Department of Anesthesiology, Rhode Island Hospital, Warren Alpert Medical School of Brown University, 593 Eddy Street, Providence, RI, 02903, USA.
| |
Collapse
|
19
|
|
20
|
Sng BL, Zeng Y, de Souza NNA, Leong WL, Oh TT, Siddiqui FJ, Assam PN, Han NR, Chan ESY, Sia AT, Cochrane Anaesthesia Group. Automated mandatory bolus versus basal infusion for maintenance of epidural analgesia in labour. Cochrane Database Syst Rev 2018; 5:CD011344. [PMID: 29770432 PMCID: PMC6494589 DOI: 10.1002/14651858.cd011344.pub2] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
BACKGROUND Childbirth may cause the most severe pain some women experience in their lifetime. Epidural analgesia is an effective form of pain relief during labour and is considered to be the reference standard. Traditionally epidural analgesia has been delivered as a continuous infusion via a catheter in the epidural space, with or without the ability for the patient to supplement the analgesia received by activating a programmable pump to deliver additional top-up doses, known as patient-controlled epidural analgesia (PCEA). There has been interest in delivering maintenance analgesic medication via bolus dosing (automated mandatory bolus - AMB) instead of the traditional continuous basal infusion (BI); recent randomized controlled trials (RCTs) have shown that the AMB technique leads to improved analgesia and maternal satisfaction. OBJECTIVES To assess the effects of automated mandatory bolus versus basal infusion for maintaining epidural analgesia in labour. SEARCH METHODS We searched CENTRAL, MEDLINE, Embase, the World Health Organization International Clinial Trials Registry Platform (WHO-ICTRP) and ClinicalTrials.gov on 16 January 2018. We screened the reference lists of all eligible trials and reviews. We also contacted authors of included studies in this field in order to identify unpublished research and trials still underway, and we screened the reference lists of the included articles for potentially relevant articles. SELECTION CRITERIA We included all RCTs that compared the use of bolus dosing AMB with continuous BI for providing pain relief during epidural analgesia for labour in women. DATA COLLECTION AND ANALYSIS We used the standard methodological procedures expected by Cochrane. Our primary outcomes were: risk of breakthrough pain with the need for anaesthetic intervention; risk of caesarean delivery; risk of instrumental delivery. Secondary outcomes included: duration of labour; local anaesthetic consumption. We used GRADE to assess the certainty of evidence for each outcome. MAIN RESULTS We included 12 studies with a total of 1121 women. Ten studies enrolled healthy nulliparous women only and two studies enrolled healthy parous women at term as well. All studies excluded women with complicated pregnancies. There were variations in the technique of initiation of epidural analgesia. Seven studies utilized the combined spinal epidural (CSE) technique, and the other five studies only placed an epidural catheter without any intrathecal injection. Seven studies utilized ropivacaine: six with fentanyl and one with sufentanil. Two studies used levobupivacaine: one with sufentanil and one with fentanyl. Three used bupivacaine with or without fentanyl. The overall risk of bias of the studies was low.AMB probably reduces the risk of breakthrough pain compared with BI for maintaining epidural analgesia for labour (from 33% to 20%; risk ratio (RR) 0.60; 95% confidence interval (CI) 0.39 to 0.92, 10 studies, 797 women, moderate-certainty evidence). AMB may make little or no difference to the risk of caesarean delivery compared to BI (15% and 16% respectively; RR 0.92; 95% CI 0.70 to 1.21, 11 studies, 1079 women, low-certainty evidence).AMB may make little or no difference in the risk of instrumental delivery compared to BI (12% and 9% respectively; RR 0.75; 95% CI 0.54 to 1.06, 11 studies, 1079 women, low-certainty evidence). There is probably little or no difference in the mean duration of labour with AMB compared to BI (mean difference (MD) -10.38 min; 95% CI -26.73 to 5.96, 11 studies, 1079 women, moderate-certainty evidence). There is probably a reduction in the hourly consumption of local anaesthetic with AMB compared to BI for maintaining epidural analgesia during labour (MD -1.08 mg/h; 95% CI -1.78 to -0.38, 12 studies, 1121 women, moderate-certainty evidence). Five out of seven studies reported an increase in maternal satisfaction with AMB compared to BI for maintaining epidural analgesia for labour; however, we did not pool these data due to their ordinal nature. Seven studies reported Apgar scores, though there was significant heterogeneity in reporting. None of the studies showed any significant difference between Apgar scores between groups. AUTHORS' CONCLUSIONS There is predominantly moderate-certainty evidence that AMB is similar to BI for maintaining epidural analgesia for labour for all measured outcomes and may have the benefit of decreasing the risk of breakthrough pain and improving maternal satisfaction while decreasing the amount of local anaesthetic needed.
Collapse
Affiliation(s)
- Ban Leong Sng
- KK Women's and Children's HospitalDepartment of Women's Anaesthesia100 Bukit Timah RoadSingaporeSingapore229899
| | - Yanzhi Zeng
- Singapore Health ServicesDepartment of AnaesthesiologyOutram RoadSingaporeSingapore169608
| | - Nurun Nisa A de Souza
- Singapore Clinical Research Institute Pte LtdEpidemiologyNanos #02‐0131, Biopolis WaySingaporeSingaporeSingapore138669
| | - Wan Ling Leong
- KK Women's and Children's HospitalDepartment of Women's Anaesthesia100 Bukit Timah RoadSingaporeSingapore229899
| | - Ting Ting Oh
- KK Women's and Children's HospitalDepartment of Women's Anaesthesia100 Bukit Timah RoadSingaporeSingapore229899
| | - Fahad Javaid Siddiqui
- The Hospital for Sick Children (SickKids)Centre for Global Child Health686 Bay StTorontoOntarioCanadaM5G 1X8
| | - Pryseley N Assam
- Duke‐NUS Graduate Medical SchoolCentre for Quantitative Medicine, Office of Clinical SciencesSingaporeSingapore138669
| | - Nian‐Lin R Han
- KK Women’s and Children’s HospitalDivision of Clinical Support Services100 Bukit Timah RoadSingaporeSingapore229899
| | - Edwin SY Chan
- Singapore Clinical Research InstituteDepartment of EpidemiologyNanos Building #02‐0131 Biopolis WaySingaporeSingapore138669
| | - Alex T Sia
- KK Women's and Children's HospitalDepartment of Women's Anaesthesia100 Bukit Timah RoadSingaporeSingapore229899
| | | |
Collapse
|