1
|
Lear CA, Dhillon SK, Nakao M, Lear BA, Georgieva A, Ugwumadu A, Stone PR, Bennet L, Gunn AJ. The peripheral chemoreflex and fetal defenses against intrapartum hypoxic-ischemic brain injury at term gestation. Semin Fetal Neonatal Med 2024; 29:101543. [PMID: 39455374 DOI: 10.1016/j.siny.2024.101543] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2024]
Abstract
Fetal hypoxemia is ubiquitous during labor and, when severe, is associated with perinatal death and long-term neurodevelopmental disability. Adverse outcomes are highly associated with barriers to care, such that developing countries have a disproportionate burden of perinatal injury. The prevalence of hypoxemia and its link to injury can be obscure, simply because the healthy fetus has robust coordinated defense mechanisms, spearheaded by the peripheral chemoreflex, such that hypoxemia only becomes apparent in the minority of cases associated with stillbirth, severe metabolic acidemia or adverse neurodevelopmental outcomes. This represents only the extreme end of the spectrum, when defense mechanisms have failed due to severe/prolonged hypoxemia, or the fetal defenses are compromised by additional risk factors. Understanding the fetal defenses to hypoxemia and when the fetus begins to decompensate is crucial to understanding perinatal health and disease, by linking antenatal health, intrapartum events, the neonatal trajectory and ultimately life-long neurodevelopmental health.
Collapse
Affiliation(s)
- Christopher A Lear
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand; Auckland City Hospital, Auckland, New Zealand.
| | - Simerdeep K Dhillon
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand
| | - Masahiro Nakao
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand; Department of Obstetrics and Gynecology, Mie University Graduate School of Medicine, Mie, Japan
| | - Benjamin A Lear
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand
| | - Antoniya Georgieva
- Nuffield Department of Women's and Reproductive Health, The John Radcliffe Hospital, University of Oxford, Oxford, United Kingdom
| | - Austin Ugwumadu
- Department of Obstetrics and Gynaecology, St George's Hospital, London, United Kingdom
| | - Peter R Stone
- Department of Obstetrics and Gynaecology, The University of Auckland, Auckland, New Zealand
| | - Laura Bennet
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand
| | - Alistair J Gunn
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand; Starship Children's Hospital, Auckland, New Zealand
| |
Collapse
|
2
|
Hussain NM, O'Halloran M, McDermott B, Elahi MA. Fetal monitoring technologies for the detection of intrapartum hypoxia - challenges and opportunities. Biomed Phys Eng Express 2024; 10:022002. [PMID: 38118183 DOI: 10.1088/2057-1976/ad17a6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Accepted: 12/20/2023] [Indexed: 12/22/2023]
Abstract
Intrapartum fetal hypoxia is related to long-term morbidity and mortality of the fetus and the mother. Fetal surveillance is extremely important to minimize the adverse outcomes arising from fetal hypoxia during labour. Several methods have been used in current clinical practice to monitor fetal well-being. For instance, biophysical technologies including cardiotocography, ST-analysis adjunct to cardiotocography, and Doppler ultrasound are used for intrapartum fetal monitoring. However, these technologies result in a high false-positive rate and increased obstetric interventions during labour. Alternatively, biochemical-based technologies including fetal scalp blood sampling and fetal pulse oximetry are used to identify metabolic acidosis and oxygen deprivation resulting from fetal hypoxia. These technologies neither improve clinical outcomes nor reduce unnecessary interventions during labour. Also, there is a need to link the physiological changes during fetal hypoxia to fetal monitoring technologies. The objective of this article is to assess the clinical background of fetal hypoxia and to review existing monitoring technologies for the detection and monitoring of fetal hypoxia. A comprehensive review has been made to predict fetal hypoxia using computational and machine-learning algorithms. The detection of more specific biomarkers or new sensing technologies is also reviewed which may help in the enhancement of the reliability of continuous fetal monitoring and may result in the accurate detection of intrapartum fetal hypoxia.
Collapse
Affiliation(s)
- Nadia Muhammad Hussain
- Discipline of Electrical & Electronic Engineering, University of Galway, Ireland
- Translational Medical Device Lab, Lambe Institute for Translational Research, University Hospital Galway, Ireland
| | - Martin O'Halloran
- Discipline of Electrical & Electronic Engineering, University of Galway, Ireland
- Translational Medical Device Lab, Lambe Institute for Translational Research, University Hospital Galway, Ireland
| | - Barry McDermott
- Translational Medical Device Lab, Lambe Institute for Translational Research, University Hospital Galway, Ireland
- College of Medicine, Nursing & Health Sciences, University of Galway, Ireland
| | - Muhammad Adnan Elahi
- Discipline of Electrical & Electronic Engineering, University of Galway, Ireland
- Translational Medical Device Lab, Lambe Institute for Translational Research, University Hospital Galway, Ireland
| |
Collapse
|
3
|
Liu B, Thilaganathan B, Bhide A. Phase-rectified signal averaging: correlation between two monitors and relationship with short-term variation of fetal heart rate. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2023; 61:765-772. [PMID: 36864541 DOI: 10.1002/uog.26192] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 02/10/2023] [Accepted: 02/14/2023] [Indexed: 06/03/2023]
Abstract
OBJECTIVES To establish the correlation between phase-rectified signal averaging (PRSA) outputs obtained from a novel self-applicable non-invasive fetal electrocardiography (NIFECG) monitor with those from computerized cardiotocography (cCTG). A secondary objective was to evaluate the potential for remote assessment of fetal wellbeing by determining the relationship between PRSA and short-term variation (STV). METHODS This was a prospective observational study of women with a singleton pregnancy over 28 + 0 weeks' gestation attending a London teaching hospital for cCTG assessment. Participants underwent concurrent cCTG and NIFECG monitoring for up to 60 min. Averaged accelerative (AAC) and decelerative (ADC) capacities and STV were derived by postprocessing and filtration of signals, generating fully (F) and partially (P) filtered results. Linear correlation and accuracy and precision analysis were performed to assess the relationship between PRSA outputs from cCTG and NIFECG, using varying anchor thresholds, and their association with STV. RESULTS A total of 306 concurrent cCTG and NIFECG traces were collected from 285 women. F-filtered NIFECG PRSA (eAAC/eADC) results were generated from 65% of traces, whereas cCTG PRSA (cAAC/cADC) outputs were generated from all. Strong correlations were observed between cAAC and F-filtered eAAC (r = 0.879, P < 0.001) and between cADC and F-filtered eADC (r = 0.895, P < 0.001). NIFECG anchor detection decreased significantly with increasing signal loss, and NIFECG PRSA indices showed considerable deviation from those of cCTG when derived from traces in which fewer than 100 anchors were detected. Removing anchor filters from NIFECG traces to generate P-filtered PRSA outputs weakened the correlation (AAC: r = 0.505, P < 0.001; ADC: r = 0.560, P < 0.001). Lowering the anchor threshold to 100 increased the yield of eAAC and eADC outputs to approximately 74%, whilst maintaining strong correlation with cAAC (r = 0.839, P < 0.001) and cADC (r = 0.815, P < 0.001), respectively. Both cAAC and cADC showed a very strong linear relationship with cCTG STV (r = 0.928, P < 0.001 and r = 0.911, P < 0.001, respectively). Similar findings were observed with eAAC (r = 0.825, P < 0.001) and eADC (r = 0.827, P < 0.001). CONCLUSIONS PRSA appears to be a method of fetal assessment equivalent to STV, but, due to its innate ability to eliminate artifacts, it generates interpretable NIFECG traces with high accuracy at a higher rate. These findings raise the possibility of self-applied at-home or remote fetal heart-rate monitoring with automated reporting, thus enabling increased surveillance in high-risk women without impacting on service demand. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
Affiliation(s)
- B Liu
- Fetal Medicine Unit, St George's University Hospitals NHS Foundation Trust, London, UK
- Vascular Biology Research Centre, Molecular and Clinical Sciences Research Institute, St George's University of London, London, UK
| | - B Thilaganathan
- Fetal Medicine Unit, St George's University Hospitals NHS Foundation Trust, London, UK
- Vascular Biology Research Centre, Molecular and Clinical Sciences Research Institute, St George's University of London, London, UK
| | - A Bhide
- Fetal Medicine Unit, St George's University Hospitals NHS Foundation Trust, London, UK
- Vascular Biology Research Centre, Molecular and Clinical Sciences Research Institute, St George's University of London, London, UK
| |
Collapse
|
4
|
Lear CA, Georgieva A, Beacom MJ, Wassink G, Dhillon SK, Lear BA, Mills OJ, Westgate JA, Bennet L, Gunn AJ. Fetal heart rate responses in chronic hypoxaemia with superimposed repeated hypoxaemia consistent with early labour: a controlled study in fetal sheep. BJOG 2023. [PMID: 36808862 DOI: 10.1111/1471-0528.17425] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2022] [Revised: 01/30/2023] [Accepted: 02/09/2023] [Indexed: 02/20/2023]
Abstract
OBJECTIVE Deceleration area (DA) and capacity (DC) of the fetal heart rate can help predict risk of intrapartum fetal compromise. However, their predictive value in higher risk pregnancies is unclear. We investigated whether they can predict the onset of hypotension during brief hypoxaemia repeated at a rate consistent with early labour in fetal sheep with pre-existing hypoxaemia. DESIGN Prospective, controlled study. SETTING Laboratory. SAMPLE Chronically instrumented, unanaesthetised near-term fetal sheep. METHODS One-minute complete umbilical cord occlusions (UCOs) were performed every 5 minutes in fetal sheep with baseline pa O2 <17 mmHg (hypoxaemic, n = 8) and >17 mmHg (normoxic, n = 11) for 4 hours or until arterial pressure fell <20 mmHg. MAIN OUTCOME MEASURES DA, DC and arterial pressure. RESULTS Normoxic fetuses showed effective cardiovascular adaptation without hypotension and mild acidaemia (lowest arterial pressure 40.7 ± 2.8 mmHg, pH 7.35 ± 0.03). Hypoxaemic fetuses developed hypotension (lowest arterial pressure 20.8 ± 1.9 mmHg, P < 0.001) and acidaemia (final pH 7.07 ± 0.05). In hypoxaemic fetuses, decelerations showed faster falls in FHR over the first 40 seconds of UCOs but the final deceleration depth was not different to normoxic fetuses. DC was modestly higher in hypoxaemic fetuses during the penultimate (P = 0.04) and final (P = 0.012) 20 minutes of UCOs. DA was not different between groups. CONCLUSION Chronically hypoxaemic fetuses had early onset of cardiovascular compromise during labour-like brief repeated UCOs. DA was unable to identify developing hypotension in this setting, while DC only showed modest differences between groups. These findings highlight that DA and DC thresholds need to be adjusted for antenatal risk factors, potentially limiting their clinical utility.
Collapse
Affiliation(s)
- C A Lear
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand
| | - A Georgieva
- Nuffield Department of Women's and Reproductive Health, The John Radcliffe Hospital, University of Oxford, Oxford, UK
| | - M J Beacom
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand
| | - G Wassink
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand
| | - S K Dhillon
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand
| | - B A Lear
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand
| | - O J Mills
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand
| | - J A Westgate
- Department of Obstetrics and Gynaecology, The University of Auckland, Auckland, New Zealand
| | - L Bennet
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand
| | - A J Gunn
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand.,Starship Children's Hospital, Auckland, New Zealand
| |
Collapse
|
5
|
Ghesquière L, Ternynck C, Sharma D, Hamoud Y, Vanspranghels R, Storme L, Houfflin-Debarge V, De Jonckheere J, Garabedian C. Heart rate markers for prediction of fetal acidosis in an experimental study on fetal sheep. Sci Rep 2022; 12:10615. [PMID: 35739219 PMCID: PMC9226053 DOI: 10.1038/s41598-022-14727-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Accepted: 06/10/2022] [Indexed: 11/09/2022] Open
Abstract
To overcome the difficulties in interpreting fetal heart rate (FHR), several tools based on the autonomic nervous system and heart rate variability (HRV) have been developed. The objective of this study was to use FHR and HRV parameters for the prediction of fetal hypoxia. It was an experimental study in the instrumented fetal sheep. Repeated umbilical cord occlusions were performed to achieve severe acidosis. Hemodynamic parameters, ECG, and blood gases were analyzed. The variables used were heart rate baseline, HRV analysis (RMSSD, SDNN, LF, HF, HFnu, Fetal Stress Index (FSI), …), and morphological analysis of decelerations. The gold standard used to classify hypoxia was the fetal arterial pH (pH < 7.10). Different multivariable statistical methods (logistic regression and decision trees) were applied for the detection of acidosis. 21 lambs were instrumented. A total of 130 pairs of FHR/fetal pH analysis were obtained of which 29 in the acidosis group and 101 in the non-acidosis group. After logistic regression model with bootstrap resampling and stepwise backward selection, only one variable was selected, FSI. The AUC of FSI alone in this model was 0.81 with a sensitivity of 0.66, specificity of 0.88, PPV of 0.61, and NPV of 0.90 considering a threshold of 68. Decision trees with CHAID and CART algorithms showed a sensitivity of 0.48 and 0.59, respectively, and a specificity of 0.94 for both. All employed methods identified HRV variables as the most predictive of acidosis. The primary variables selected automatically were those from the HRV. Supporting the use of FHRV measures for the screening of fetal acidosis during labour is interesting.
Collapse
Affiliation(s)
- Louise Ghesquière
- Univ. Lille, CHU Lille, ULR 2694-METRICS-Evaluation des technologies de santé et des pratiques médicales, 59000, Lille, France.
- Department of Obstetrics, CHU Lille, 59000, Lille, France.
- Department of Obstetrics, CHU Lille, Avenue Eugène Avinée, 59037, Lille Cedex, France.
| | - C Ternynck
- Univ. Lille, CHU Lille, ULR 2694-METRICS-Evaluation des technologies de santé et des pratiques médicales, 59000, Lille, France
- Department of Biostatistics, CHU Lille, 59000, Lille, France
| | - D Sharma
- Univ. Lille, CHU Lille, ULR 2694-METRICS-Evaluation des technologies de santé et des pratiques médicales, 59000, Lille, France
- Department of Pediatric Surgery, CHU Lille, 59000, Lille, France
| | - Y Hamoud
- Univ. Lille, CHU Lille, ULR 2694-METRICS-Evaluation des technologies de santé et des pratiques médicales, 59000, Lille, France
- Department of Obstetrics, CHU Lille, 59000, Lille, France
| | - R Vanspranghels
- Univ. Lille, CHU Lille, ULR 2694-METRICS-Evaluation des technologies de santé et des pratiques médicales, 59000, Lille, France
- Department of Obstetrics, CHU Lille, 59000, Lille, France
| | - L Storme
- Univ. Lille, CHU Lille, ULR 2694-METRICS-Evaluation des technologies de santé et des pratiques médicales, 59000, Lille, France
- Department of Neonatology, CHU Lille, 59000, Lille, France
| | - V Houfflin-Debarge
- Univ. Lille, CHU Lille, ULR 2694-METRICS-Evaluation des technologies de santé et des pratiques médicales, 59000, Lille, France
- Department of Obstetrics, CHU Lille, 59000, Lille, France
| | - J De Jonckheere
- Univ. Lille, CHU Lille, ULR 2694-METRICS-Evaluation des technologies de santé et des pratiques médicales, 59000, Lille, France
- CHU Lille, CIC-IT 1403, 59000, Lille, France
| | - C Garabedian
- Univ. Lille, CHU Lille, ULR 2694-METRICS-Evaluation des technologies de santé et des pratiques médicales, 59000, Lille, France
- Department of Obstetrics, CHU Lille, 59000, Lille, France
| |
Collapse
|
6
|
López-Justo C, Pliego-Carrillo AC, Ledesma-Ramírez CI, Mendieta-Zerón H, Peña-Castillo MÁ, Echeverría JC, Rodríguez-Arce J, Reyes-Lagos JJ. Differences in the Asymmetry of Beat-to-Beat Fetal Heart Rate Accelerations and Decelerations at Preterm and Term Active Labor. SENSORS 2021; 21:s21248249. [PMID: 34960343 PMCID: PMC8704786 DOI: 10.3390/s21248249] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Revised: 11/30/2021] [Accepted: 12/06/2021] [Indexed: 11/29/2022]
Abstract
The fetal autonomic nervous system responds to uterine contractions during active labor as identified by changes in the accelerations and decelerations of fetal heart rate (FHR). Thus, this exploratory study aimed to characterize the asymmetry differences of beat-to-beat FHR accelerations and decelerations in preterm and term fetuses during active labor. In an observational study, we analyzed 10 min of fetal R-R series collected from women during active preterm labor (32–36 weeks of pregnancy, n = 17) and active term labor (38–40 weeks of pregnancy, n = 27). These data were used to calculate the Deceleration Reserve (DR), which is a novel parameter that quantifies the asymmetry of the average acceleration and deceleration capacity of the heart. In addition, relevant multiscale asymmetric indices of FHR were also computed. Lower values of DR, calculated with the input parameters of T = 50 and s = 10, were associated with labor occurring at the preterm condition (p = 0.0131). Multiscale asymmetry indices also confirmed significant (p < 0.05) differences in the asymmetry of FHR. Fetuses during moderate premature labor may experience more decaying R-R trends and a lower magnitude of decelerations compared to term fetuses. These differences of FHR dynamics might be related to the immaturity of the fetal cardiac autonomic nervous system as identified by this system response to the intense uterine activity at active labor.
Collapse
Affiliation(s)
- Carolina López-Justo
- Facultad de Medicina (School of Medicine), Universidad Autónoma del Estado de México (Autonomous University of Mexico State), Toluca de Lerdo 50180, Mexico; (C.L.-J.); (A.C.P.-C.); (C.I.L.-R.); (H.M.-Z.)
| | - Adriana Cristina Pliego-Carrillo
- Facultad de Medicina (School of Medicine), Universidad Autónoma del Estado de México (Autonomous University of Mexico State), Toluca de Lerdo 50180, Mexico; (C.L.-J.); (A.C.P.-C.); (C.I.L.-R.); (H.M.-Z.)
| | - Claudia Ivette Ledesma-Ramírez
- Facultad de Medicina (School of Medicine), Universidad Autónoma del Estado de México (Autonomous University of Mexico State), Toluca de Lerdo 50180, Mexico; (C.L.-J.); (A.C.P.-C.); (C.I.L.-R.); (H.M.-Z.)
| | - Hugo Mendieta-Zerón
- Facultad de Medicina (School of Medicine), Universidad Autónoma del Estado de México (Autonomous University of Mexico State), Toluca de Lerdo 50180, Mexico; (C.L.-J.); (A.C.P.-C.); (C.I.L.-R.); (H.M.-Z.)
- Hospital Materno Perinatal Mónica Pretelini Sáenz, Instituto de Salud del Estado de México (Health Institute of Mexico State), Toluca de Lerdo 50010, Mexico
| | - Miguel Ángel Peña-Castillo
- División de Ciencias Básicas e Ingeniería (Basic Science and Engineering Division), Universidad Autónoma Metropolitana Unidad Iztapalapa (Metropolitan Autonomous University Campus Iztapalapa), Iztapalapa 09340, Mexico; (M.Á.P.-C.); (J.C.E.)
| | - Juan Carlos Echeverría
- División de Ciencias Básicas e Ingeniería (Basic Science and Engineering Division), Universidad Autónoma Metropolitana Unidad Iztapalapa (Metropolitan Autonomous University Campus Iztapalapa), Iztapalapa 09340, Mexico; (M.Á.P.-C.); (J.C.E.)
| | - Jorge Rodríguez-Arce
- Facultad de Ingeniería (School of Engineering), Universidad Autónoma del Estado de México (Autonomous University of Mexico State), Toluca de Lerdo 50100, Mexico;
| | - José Javier Reyes-Lagos
- Facultad de Medicina (School of Medicine), Universidad Autónoma del Estado de México (Autonomous University of Mexico State), Toluca de Lerdo 50180, Mexico; (C.L.-J.); (A.C.P.-C.); (C.I.L.-R.); (H.M.-Z.)
- Correspondence:
| |
Collapse
|
7
|
Zamora Del Pozo C, Chóliz Ezquerro M, Mejía I, Díaz de Terán Martínez-Berganza E, Esteban LM, Rivero Alonso A, Castán Larraz B, Andeyro García M, Savirón Cornudella R. Diagnostic capacity and interobserver variability in FIGO, ACOG, NICE and Chandraharan cardiotocographic guidelines to predict neonatal acidemia. J Matern Fetal Neonatal Med 2021; 35:8498-8506. [PMID: 34652249 DOI: 10.1080/14767058.2021.1986479] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
OBJECTIVE Despite its routine use in intrapartum care, the technique of fetal cardiotocography has some limitations. The aim of this study is to analyze the predictive capacity and interobserver agreement in the latest versions of four international cardiotocography guidelines: Federation of Gynecology and Obstetrics (FIGO), American College of Obstetrics and Gynecology (ACOG), the National Institute for Health and Care Excellence (NICE) and Chandraharan, used to predict neonatal acidemia. STUDY DESIGN The last 30 min of 150 cardiotocographic records were analyzed over all the pH ranges and were blindly evaluated by three independent reviewers. The sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve (AUC) were calculated to assess the predictive capacity of each fetal cardiotocographic guideline. The degree of interobserver agreement was evaluated with the Fleiss Kappa coefficient. RESULTS Observers found fetal cardiotocography guidelines to have a variable sensitivity and specificity. The Chandraharan classification reached the highest sensitivity (78.79%), while ACOG had the highest specificity (95.73%). On average for the three observers, Chandraharan had the highest discrimination capacity for neonatal acidemia, although this was only moderate (AUC 0.66; 95%CI, 0.55-0.77) and did not differ significantly from the remaining guidelines. The degree of agreement among the three observers, assessed according to the Fleiss Kappa coefficient, was generally acceptable or moderate for all items and classifications, being highest with the FIGO classification (ĸ = 0.35; 95%CI, 0.28-0.41) and lowest with the ACOG (ĸ = 0.23; 95%CI, 0.16-0.30). CONCLUSION Although all the guidelines have a moderate capacity to predict neonatal acidemia, the Chandraharan guideline has the highest capacity. This follows a different approach from the others in that it relies on interpretations of cardiotocographic traces based on fetal physiology. The degree of interobserver agreement is, in general, acceptable for the four guidelines, and is the highest for FIGO.
Collapse
Affiliation(s)
| | | | - Inmaculada Mejía
- Department of Obstetrics and Gynecology, Hospital Universitario 12 de Octubre, Madrid, Spain
| | | | - Luis Mariano Esteban
- Universidad de Zaragoza, Escuela Universitaria Politécnica de la Almunia, C/Mayor s/n, La Almunia de Doña Godina, Spain
| | | | | | | | | |
Collapse
|
8
|
Sholapurkar SL. The present and future of intrapartum computerized cardiotocography: role of pattern recognition incorporating single vs. multiple parameters. J Matern Fetal Neonatal Med 2021; 35:7452-7458. [PMID: 34402369 DOI: 10.1080/14767058.2021.1949453] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Computer assisted cardiotocography holds a great promise in minimizing human errors thereby improving perinatal outcome. Despite exponential growth (Moore's law) in computing power for decades, this promise remains unrealized. The systematic analyses of studies on computerized cardiotocography offer little guide to future. This analytical review presents a more qualitative discussion of available evidence as well as concepts regarding the development and acceptance of computerized cardiotocography. To begin with, a workable approach would be for computer algorithms to follow the most scientific visual cardiotocography interpretation frameworks incorporating multiple fetal heart rate parameters and uterine contractions. This ability could be studied and form the basis for regulation of computer algorithms. Addition of background risk factors would be another step. This may take form of familiar multi-tier systems or new alternative strategies like the fetal reserve index. "Machine learning" will remain challenging because of complex variability in fetal-maternal conditions, labor characteristics and clinical intervention changing the outcomes. Randomized controlled trials of adequate size may remain very rare. However, prospective and retrospective testing of computer algorithms with careful qualitative and comparative approach would help clinicians and hospital managers in their decisions. Singular parameters like the popular "deceleration area" and "deceleration capacity" have poor predictive value for fetal acidemia or hypoxic injury. Scientific pattern-recognition of important fetal heart rate parameters like decelerations seems crucial for visual as well as computerized cardiotocography. Success of computerizedcardiotocography depends on team effort by the obstetricians with in-depth practical knowledge/experience and skilled artificial intelligence (AI) specialists.
Collapse
|
9
|
Sholapurkar SL. Deceleration area and deceleration capacity: deficient predictors of fetal acidaemia in human labour. Visual versus computerised cardiotocography. BJOG 2021; 128:2054-2055. [PMID: 34342133 DOI: 10.1111/1471-0528.16824] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/05/2021] [Indexed: 11/29/2022]
|
10
|
Gragnano E, Saccone G, Tagliaferri S, Esposito G, Paino JA, Campanile M, Maruotti GM, Guida M. Computerized cardiotocography in singleton gestations with diabetes mellitus: a retrospective study. Minerva Obstet Gynecol 2021; 74:161-164. [PMID: 34096692 DOI: 10.23736/s2724-606x.21.04786-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE To evaluate the use of computerized cardiotocography (C-CTG) in women with diabetes mellitus. METHODS This was a retrospective cohort study of women with diabetes mellitus referred to University of Naples Federico II from January 2018 to January 2020 for antenatal monitoring. Only women who underwent antenatal monitoring with C-CTG were included in the study. For the purpose of this study only the C-CTG recorded at the time of outpatient admission were analysed. Women were divided into four groups: 1. Women with diabetes mellitus type 1; 2. Women with diabetes mellitus type 2; 3. Women with gestational diabetes mellitus (GDM); 4. Control group without diabetes mellitus. The primary outcome of the study was the C-CTG short term variability (STV). RESULTS A total of 298 patients were included in the study, 89 with type 1 diabetes (group 1), 27 with type 2 diabetes (group 2), 77 with GDM (group 3) and 105 controls (group 4). Fetal heart rate was statistically higher in pregnant women with pre-pregnancy diabetes both Type 1 and 2 compared to gestational diabetes and physiological pregnancies. The parameters of STV, APRS and DPRS were statistically lower in the pregnant group with pre-pregnancy type 1 diabetes than in type 2 and compared to group 3 and 4. CONCLUSIONS Fetal heart rate was statistically higher in pregnant women with pre-pregnancy diabetes, both Type 1 and 2, compared to gestational diabetes and controls. STV, APRS and DPRS were statistically lower in the pregnant group with pre-pregnancy type 1 diabetes than in type 2 and compared to group 3 and 4.
Collapse
Affiliation(s)
- Elisabetta Gragnano
- Department of Neuroscience, Reproductive Sciences and Dentistry, School of Medicine, University of Naples Federico II, Naples, Italy -
| | - Gabriele Saccone
- Department of Neuroscience, Reproductive Sciences and Dentistry, School of Medicine, University of Naples Federico II, Naples, Italy
| | - Salvatore Tagliaferri
- Department of Neuroscience, Reproductive Sciences and Dentistry, School of Medicine, University of Naples Federico II, Naples, Italy
| | - Giuseppina Esposito
- Department of Neuroscience, Reproductive Sciences and Dentistry, School of Medicine, University of Naples Federico II, Naples, Italy
| | - Jessica A Paino
- Department of Neuroscience, Reproductive Sciences and Dentistry, School of Medicine, University of Naples Federico II, Naples, Italy
| | - Marta Campanile
- Department of Neuroscience, Reproductive Sciences and Dentistry, School of Medicine, University of Naples Federico II, Naples, Italy
| | - Giuseppe M Maruotti
- Department of Neuroscience, Reproductive Sciences and Dentistry, School of Medicine, University of Naples Federico II, Naples, Italy
| | - Maurizio Guida
- Department of Neuroscience, Reproductive Sciences and Dentistry, School of Medicine, University of Naples Federico II, Naples, Italy
| |
Collapse
|
11
|
Georgieva A, Lear CA, Westgate JA, Kasai M, Miyagi E, Ikeda T, Gunn AJ, Bennet L. Deceleration area and capacity during labour-like umbilical cord occlusions identify evolving hypotension: a controlled study in fetal sheep. BJOG 2021; 128:1433-1442. [PMID: 33369871 DOI: 10.1111/1471-0528.16638] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/18/2020] [Indexed: 12/20/2022]
Abstract
OBJECTIVE Cardiotocography is widely used to assess fetal well-being during labour. The positive predictive value of current clinical algorithms to identify hypoxia-ischaemia is poor. In experimental studies, fetal hypotension is the strongest predictor of hypoxic-ischaemic injury. Cohort studies suggest that deceleration area and deceleration capacity of the fetal heart rate trace correlate with fetal acidaemia, but it is not known whether they are indices of fetal arterial hypotension. DESIGN Prospective, controlled study. SETTING Laboratory. SAMPLE Near-term fetal sheep. METHODS One minute of complete umbilical cord occlusions (UCOs) every 5 minutes (1:5 min, n = 6) or every 2.5 minutes (1:2.5 min, n = 12) for 4 hours or until fetal mean arterial blood pressure fell <20 mmHg. MAIN OUTCOME MEASURES Deceleration area and capacity during the UCO series were related to evolving hypotension. RESULTS The 1:5 min group developed only mild metabolic acidaemia, without hypotension. By contrast, 10/12 fetuses in the 1:2.5-min group progressively developed severe metabolic acidaemia and hypotension, reaching 16.8 ± 0.9 mmHg after 71.2 ± 6.7 UCOs. Deceleration area and capacity remained unchanged throughout the UCO series in the 1:5-min group, but progressively increased in the 1:2.5-min group. The severity of hypotension was closely correlated with both deceleration area (P < 0.001, R2 = 0.66, n = 18) and capacity (P < 0.001, R2 = 0.67, n = 18). Deceleration area and capacity predicted development of hypotension at a median of 103 and 123 minutes before the final occlusion, respectively. CONCLUSIONS Both deceleration area and capacity were strongly associated with developing fetal hypotension, supporting their potential to improve identification of fetuses at risk of hypotension leading to hypoxic-ischaemic injury during labour. TWEETABLE ABSTRACT Deceleration area and capacity of fetal heart rate identify developing hypotension during labour-like hypoxia.
Collapse
Affiliation(s)
- A Georgieva
- Nuffield Department of Women's and Reproductive Health, The John Radcliffe Hospital, University of Oxford, Oxford, UK
| | - C A Lear
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand
| | - J A Westgate
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand
| | - M Kasai
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand.,The Department of Obstetrics and Gynecology, Yokohama City University, Yokohama, Japan
| | - E Miyagi
- The Department of Obstetrics and Gynecology, Yokohama City University, Yokohama, Japan
| | - T Ikeda
- Department of Obstetrics and Gynecology, Mie University, Mie, Japan
| | - A J Gunn
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand
| | - L Bennet
- Fetal Physiology and Neuroscience Group, Department of Physiology, The University of Auckland, Auckland, New Zealand
| |
Collapse
|
12
|
Antonelli MC, Frasch MG, Rumi M, Sharma R, Zimmermann P, Molinet MS, Lobmaier SM. Early Biomarkers and Intervention Programs for the Infant Exposed to Prenatal Stress. Curr Neuropharmacol 2021; 20:94-106. [PMID: 33550974 PMCID: PMC9199558 DOI: 10.2174/1570159x19666210125150955] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 11/06/2020] [Accepted: 01/16/2021] [Indexed: 11/22/2022] Open
Abstract
Functional development of affective and reward circuits, cognition and response inhibition later in life exhibits vulnerability periods during gestation and early childhood. Extensive evidence supports the model that exposure to stressors in the gestational period and early postnatal life increases an individual's susceptibility to future impairments of functional development. Recent versions of this model integrate epigenetic mechanisms of the developmental response. Their understanding will guide the future treatment of the associated neuropsychiatric disorders. A combination of non-invasively obtainable physiological signals and epigenetic biomarkers related to the principal systems of the stress response, the Hypothalamic-Pituitary axis (HPA) and the Autonomic Nervous System (ANS), are emerging as the key predictors of neurodevelopmental outcomes. Such electrophysiological and epigenetic biomarkers can prove to timely identify children benefiting most from early intervention programs. Such programs should ameliorate future disorders in otherwise healthy children. The recently developed Early Family-Centered Intervention Programs aim to influence the care and stimuli provided daily by the family and improving parent/child attachment, a key element for healthy socio-emotional adult life. Although frequently underestimated, such biomarker-guided early intervention strategy represents a crucial first step in the prevention of future neuropsychiatric problems and in reducing their personal and societal impact.
Collapse
Affiliation(s)
- Marta C Antonelli
- Instituto de Biología Celular y Neurociencia "Prof. E. De Robertis", Facultad de Medicina, UBA, Buenos Aires. Argentina
| | - Martin G Frasch
- Department of Obstetrics and Gynecology, University of Washington, Seattle, WA. United States
| | - Mercedes Rumi
- Instituto de Biología Celular y Neurociencia "Prof. E. De Robertis", Facultad de Medicina, UBA, Buenos Aires. Argentina
| | - Ritika Sharma
- Department of Obstetrics and Gynecology, Klinikum rechts der Isar, Technical University of Munich. Germany
| | - Peter Zimmermann
- Department of Obstetrics and Gynecology, Klinikum rechts der Isar, Technical University of Munich. Germany
| | - Maria Sol Molinet
- Department of Obstetrics and Gynecology, Klinikum rechts der Isar, Technical University of Munich. Germany
| | - Silvia M Lobmaier
- Department of Obstetrics and Gynecology, Klinikum rechts der Isar, Technical University of Munich. Germany
| |
Collapse
|
13
|
Frasch MG, Shen C, Wu HT, Mueller A, Neuhaus E, Bernier RA, Kamara D, Beauchaine TP. Brief Report: Can a Composite Heart Rate Variability Biomarker Shed New Insights About Autism Spectrum Disorder in School-Aged Children? J Autism Dev Disord 2021; 51:346-356. [PMID: 32449059 DOI: 10.1007/s10803-020-04467-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Several studies show altered heart rate variability (HRV) in autism spectrum disorder (ASD), but findings are neither universal nor specific to ASD. We apply a set of linear and nonlinear HRV measures-including phase rectified signal averaging-to segments of resting ECG data collected from school-age children with ASD, age-matched typically developing controls, and children with other psychiatric conditions characterized by altered HRV (conduct disorder, depression). We use machine learning to identify time, frequency, and geometric signal-analytical domains that are specific to ASD (receiver operating curve area = 0.89). This is the first study to differentiate children with ASD from other disorders characterized by altered HRV. Despite a small cohort and lack of external validation, results warrant larger prospective studies.
Collapse
Affiliation(s)
- Martin G Frasch
- Department of Obstetrics and Gynecology, University of Washington, Seattle, WA, USA
- Center on Human Development and Disability, University of Washington, Seattle, WA, USA
| | - Chao Shen
- Department of Mathematics, Duke University, Durham, NC, USA
| | - Hau-Tieng Wu
- Department of Mathematics, Duke University, Durham, NC, USA
- Department of Statistical Science, Duke University, Durham, NC, USA
| | - Alexander Mueller
- Innere Medizin 1, Department of Cardiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Emily Neuhaus
- Seattle Children's Research Institute, Center for Child Health, Behavior, and Development, Seattle, WA, USA.
- Seattle Children's Autism Center, Seattle, WA, USA.
| | - Raphael A Bernier
- Department of Psychiatry and Behavioral Sciences, University of Washington, Seattle, WA, USA
| | - Dana Kamara
- Department of Psychology, The Ohio State University, Columbus, OH, USA
| | | |
Collapse
|
14
|
Moors S, Joshi R, Bullens LM, van Oostrum NHM, Regis M, van den Heuvel ER, Oei SG, van Laar JOEH, van der Hout-van der Jagt MB. A randomized controlled trial studying the effect of maternal hyperoxygenation on fetal heart rate in suspected fetal distress. Physiol Meas 2020; 41:115002. [PMID: 33049730 DOI: 10.1088/1361-6579/abc0b6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE To investigate the effect of maternal hyperoxygenation on fetal heart rate (FHR) when applied for suspected fetal distress during the second stage of term labor. APPROACH A single-center randomized controlled trial was conducted in a tertiary care hospital in The Netherlands. Participants were included during the second stage of labor in case of an intermediary or abnormal FHR pattern. Patients were randomized to receive either 100% oxygen at 10 l/min until delivery, or conventional care without additional oxygen. The primary outcome was the change in FHR pattern before and after the onset of the study, measured as the change in depth and duration of FHR decelerations. Secondary outcome measures were features based on phase-rectified signal averaging (PRSA), baseline assignability, and deceleration characteristics of the FHR pattern. MAIN RESULTS Between March 2016 and April 2018, 117 women were included. The FHR pattern could be analyzed for 71 participants, the other 46 women delivered before the end of the post time-frame. A 2.3% reduction in depth and duration of FHR decelerations was found after maternal hyperoxygenation, compared to a 10% increase in the control group (p = 0.24). Maternal hyperoxygenation had a significantly positive effect on PRSA metrics, with a decrease in PRSA-acceleration capacity (p = 0.03) and PRSA-deceleration capacity (p = 0.02) in the intervention group compared to the control group. SIGNIFICANCE The difference in depth and duration of decelerations after the start of the study was not significantly different between both study groups. A statistically significant positive effect on PRSA-deceleration capacity and PRSA-acceleration capacity was found after maternal hyperoxygenation, which might be associated with a positive effect on neonatal outcome.
Collapse
Affiliation(s)
- S Moors
- Department of Obstetrics and Gynecology, Máxima Medical Center, Veldhoven, The Netherlands. Eindhoven MedTech Innovation Center (e/MTIC), Groene Loper 19, Eindhoven 5600 MB, The Netherlands. Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Kapaya H, Jacques R, Almond T, Rosser MH, Anumba D. Is short-term-variation of fetal-heart-rate a better predictor of fetal acidaemia in labour? A feasibility study. PLoS One 2020; 15:e0236982. [PMID: 32745099 PMCID: PMC7398510 DOI: 10.1371/journal.pone.0236982] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Accepted: 07/18/2020] [Indexed: 11/22/2022] Open
Abstract
Background Continuous intrapartum fetal monitoring is challenging and its clinical benefits are debated. The project evaluated whether short-term-variation (STV) and other computerised fetal heart rate (FHR) parameters (baseline FHR, long-term-variation, accelerations and decelerations) predicted acidaemia at birth. The aims of the study were to assess the changes in FHR pattern during labour and determine the feasibility of undertaking a definitive trial by reporting the practicalities of using the monitoring device, participant recruitment, data collection and staff training. Methods 200 high-risk women carrying a term singleton, non-anomalous fetus, requiring continuous FHR monitoring in labour were consented to participate from the Jessop Wing maternity unit, Sheffield, UK. The trans-abdominal fetal ECG monitor was placed as per clinical protocol. During the monitoring session, clinicians were blinded to the computerised FHR parameters. We analysed the last hour of the FHR and its ability to predict umbilical arterial blood pH <7.20 using receiver operator characteristics (ROC) curves. Results Of 200 women, 137 cases were excluded as either the monitor did not work from the onset of labour (n = 30), clinical staff did not return or used the monitor on another patient (n = 37), umbilical cord blood not obtained (n = 25), FHR data not recorded within an hour of birth (n = 34) and other reasons (n = 11). In 63 cases included in the final analysis, the computer-derived FHR parameters did not show significant correlation with umbilical artery cord pH <7.20. Labour was associated with a significant increase in short and long term variation of FHR and number of deceleration (P<0.001). However, baseline FHR decreased significantly before delivery (P<0.001). Conclusions The project encountered a number of challenges, with learning points crucial to informing the design of a large study to evaluate the potential place of intrapartum computerised FHR parameters, using abdominal fetal ECG monitor before its clinical utility and more widespread adoption can be ascertained.
Collapse
Affiliation(s)
- Habiba Kapaya
- Sheffield Teaching Hospitals, NHS Foundation Trust, Tree Root Walk, Sheffield, United Kingdom
- * E-mail:
| | - Richard Jacques
- Medical Statistics Group, School of Health and Related Research (ScHARR), University of Sheffield, United Kingdom
| | - Thomas Almond
- Obstetrics and Gynaecology, Sheffield Teaching Hospitals, NHS Foundation Trust, Tree Root Walk, Sheffield, United Kingdom
| | - Miss Hilary Rosser
- Obstetrics and Gynaecology, Sheffield Teaching Hospitals, NHS Foundation Trust, Tree Root Walk, Sheffield, United Kingdom
| | - Dilly Anumba
- Academic Unit of Reproductive and Developmental Medicine, University of Sheffield, Tree Root Walk, Sheffield, United Kingdom
| |
Collapse
|