1
|
Seifalian A, Digesu A, Khullar V. The use of animal models in preclinical investigations for the development of a surgical mesh for pelvic organ prolapse. Int Urogynecol J 2024; 35:741-758. [PMID: 38358519 PMCID: PMC11052796 DOI: 10.1007/s00192-024-05741-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Accepted: 01/20/2024] [Indexed: 02/16/2024]
Abstract
INTRODUCTION AND HYPOTHESIS Polypropylene (PP) mesh for the treatment of pelvic organ prolapse (POP) has raised substantial concerns over long-term complications, leading to its ban in multiple countries. In response, emerging materials are being explored as alternatives for prolapse surgery. Preclinical animal models have historically played a pivotal role in validating medical devices, prior to clinical trials. Successful translation of these materials necessitates the identification of suitable animal models that replicate the female human pelvis and its biomechanical properties. Preclinical in vivo testing assesses the safety of surgical mesh and treatment efficacy in preventing POP recurrence. METHODS The research critically reviews animal models used for preclinical pelvic mesh testing over the last decade and proposes a promising model for future preclinical studies. RESULTS Rats were the most common mammal used for toxicity and biocompatibility investigations through abdominal implantation. Although non-human primates serve as a gold standard for efficacy testing, ethical considerations limit their use owing to their close biological and cognitive resemblance to humans. Consequently, sheep were the most preferred large animal model owing to their reproductive system similarities and propensity for spontaneous POP following parity. CONCLUSION The study contributes valuable insights into the selection of appropriate animal models for preclinical pelvic mesh testing, offering guidance that is crucial for enhancing the safety and efficacy of novel surgical interventions in the treatment of POP.
Collapse
Affiliation(s)
- Amelia Seifalian
- Department of Urogynaecology, Imperial College London, London, UK.
| | - Alex Digesu
- Department of Urogynaecology, Imperial College London, London, UK
| | - Vikram Khullar
- Department of Urogynaecology, Imperial College London, London, UK
| |
Collapse
|
2
|
Ding X, Zhu J, Liu A, Guo Q, Cao Q, Xu Y, Hua Y, Yang Y, Li P. Preparation and Biocompatibility Study of Contrast-Enhanced Hernia Mesh Material. Tissue Eng Regen Med 2022; 19:703-715. [PMID: 35612710 DOI: 10.1007/s13770-022-00460-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Revised: 04/09/2022] [Accepted: 04/11/2022] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND Meshes play a crucial role in hernia repair. However, the displacement of mesh inevitably leads to various associated complications. This process is difficult to be traced by conventional imaging means. The purpose of this study is to create a contrast-enhanced material with high-density property that can be detected by computed tomography (CT). METHODS The contrast-enhanced monofilament was manufactured from barium sulfate nanoparticles and medical polypropylene (PP/Ba). To characterize the composite, stress tensile tests and scanning electron microscopy (SEM) was performed. Toxicity and biocompatibility of PP/Ba materials was verified by in vitro cellular assays. Meanwhile, the inflammatory response was tested by protein adsorption assay. In addition, an animal model was established to demonstrate the long-term radiographic effect of the composite material in vivo. Subsequent pathological tests confirmed its in vivo compatibility. RESULTS The SEM revealed that the main component of the monofilament is carbon. In vitro cell experiments demonstrated that novel material does not affect cell activity and proliferation. Protein adsorption assays indicated that the contrast-enhanced material does not cause additional inflammatory responses. In addition, in vivo experiments illustrated that PP/Ba mesh can be detected by CT and has good in vivo compatibility. CONCLUSION These results highlight the excellent biocompatibility of the contrast-enhanced material, which is suitable for human abdominal wall tissue engineering.
Collapse
Affiliation(s)
- Xuzhong Ding
- Department of Gastrointestinal Surgery, Affiliated Hospital of Nantong University, No. 20 Xisi Road, Chongchuan District, Nantong, 226000, China
| | - Jiachen Zhu
- Key Laboratory of Neuroregeneration of Jiangsu and Ministry of Education, Co-Innovation Center of Neuroregeneration, Nantong University, No. 19, Qixiu Road, Chongchuan District, Nantong, Jiangsu, China
| | - Anning Liu
- Department of Gastrointestinal Surgery, Affiliated Hospital of Nantong University, No. 20 Xisi Road, Chongchuan District, Nantong, 226000, China
| | - Qiyang Guo
- Chemistry and Chemical Engineering, Nantong University, Nantong, China
| | - Qing Cao
- Department of Gastrointestinal Surgery, Affiliated Hospital of Nantong University, No. 20 Xisi Road, Chongchuan District, Nantong, 226000, China
| | - Yu Xu
- Department of Gastrointestinal Surgery, Affiliated Hospital of Nantong University, No. 20 Xisi Road, Chongchuan District, Nantong, 226000, China
| | - Ye Hua
- Department of Imaging, Affiliated Hospital of Nantong University, Nantong, China
| | - Yumin Yang
- Key Laboratory of Neuroregeneration of Jiangsu and Ministry of Education, Co-Innovation Center of Neuroregeneration, Nantong University, No. 19, Qixiu Road, Chongchuan District, Nantong, Jiangsu, China.
| | - Peng Li
- Department of Gastrointestinal Surgery, Affiliated Hospital of Nantong University, No. 20 Xisi Road, Chongchuan District, Nantong, 226000, China.
| |
Collapse
|