1
|
Wilkins RC, Beaton-Green LA. Development of high-throughput systems for biodosimetry. RADIATION PROTECTION DOSIMETRY 2023; 199:1477-1484. [PMID: 37721060 PMCID: PMC10720693 DOI: 10.1093/rpd/ncad060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 01/24/2023] [Accepted: 02/08/2023] [Indexed: 09/19/2023]
Abstract
Biomarkers for ionising radiation exposure have great utility in scenarios where there has been a potential exposure and physical dosimetry is missing or in dispute, such as for occupational and accidental exposures. Biomarkers that respond as a function of dose are particularly useful as biodosemeters to determine the dose of radiation to which an individual has been exposed. These dose measurements can also be used in medical scenarios to track doses from medical exposures and even have the potential to identify an individual's response to radiation exposure that could help tailor treatments. The measurement of biomarkers of exposure in medicine and for accidents, where a larger number of samples would be required, is limited by the throughput of analysis (i.e. the number of samples that could be processed and analysed), particularly for microscope-based methods, which tend to be labour-intensive. Rapid analysis in an emergency scenario, such as a large-scale accident, would provide dose estimates to medical practitioners, allowing timely administration of the appropriate medical countermeasures to help mitigate the effects of radiation exposure. In order to improve sample throughput for biomarker analysis, much effort has been devoted to automating the process from sample preparation through automated image analysis. This paper will focus mainly on biological endpoints traditionally analysed by microscopy, specifically dicentric chromosomes, micronuclei and gamma-H2AX. These endpoints provide examples where sample throughput has been improved through automated image acquisition, analysis of images acquired by microscopy, as well as methods that have been developed for analysis using imaging flow cytometry.
Collapse
Affiliation(s)
- Ruth C Wilkins
- Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa K1A 1C1, Canada
| | - Lindsay A Beaton-Green
- Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa K1A 1C1, Canada
| |
Collapse
|
2
|
Wang T, Tu Y, Wang K, Gong S, Zhang G, Zhang Y, Meng Y, Wang T, Li A, Cui J, Liu H, Tang W, Xi J, Cao Y, Luan Y, Christiani DC, Au W, Xia ZL. Associations of blood lead levels with multiple genotoxic biomarkers among workers in China: A population-based study. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2020; 273:116181. [PMID: 33508628 DOI: 10.1016/j.envpol.2020.116181] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 11/16/2020] [Accepted: 11/27/2020] [Indexed: 06/12/2023]
Abstract
Carcinogenic effects from low doses of lead (Pb) exposure to populations have been suspected but not concluded. Therefore, a large-scale cross-sectional study was conducted by us to investigate genotoxic effects from Pb exposure during 2016-2018 in North China. Blood lead levels (BLLs) and cumulative blood lead levels (CBLLs) were measured. Multiple relevant biomarkers were used to assess genotoxicity of Pb: mitochondrial DNA copy number (mtDNAcn, n = 871), Comet Tail Intensity (n = 872), γ-H2AX (n = 345), relative telomere length (rTL, n = 757), micronuclei (MN, n = 934) and phosphatidylinositol glycan class A mutation (PIG-A, n = 362). The BLL data show right-skewed distribution, with increase of the median (P25, P75) from 17.4 (8.9, 26.4) μg/dl in 2016 to 18.5 (10.5, 27.2) μg/dl in 2017, and to 20.8 (11.3, 31.0) μg/dl in 2018. Multivariate regression analyses show that mtDNAcn was non-linearly associated with BLLs or CBLLs, i.e. decreased at low levels but increased at the higher levels. Comet and Micronuclei data show positive dose-response relationships with BLLs as well as CBLLs. γ-H2AX data show an overall increased trend with BLLs while rTL data show a shortening trend. No associations were found for PIG-A mutation with Pb exposure. Our findings indicate that current low dose exposure to Pb can still cause health hazards to occupational populations, and the mechanism may be via the induction of DNA & chromosome damage rather than via the mutagenesis pathway.
Collapse
Affiliation(s)
- Tuanwei Wang
- Department of Occupational Health & Toxicology, School of Public Health, Shanghai Medical College of Fudan University, 130 Dongan Road, Shanghai 200032, China
| | - Yuting Tu
- Department of Occupational Health & Toxicology, School of Public Health, Shanghai Medical College of Fudan University, 130 Dongan Road, Shanghai 200032, China
| | - Kan Wang
- Department of Occupational Health & Toxicology, School of Public Health, Shanghai Medical College of Fudan University, 130 Dongan Road, Shanghai 200032, China
| | - Shiyang Gong
- Department of Occupational Health & Toxicology, School of Public Health, Shanghai Medical College of Fudan University, 130 Dongan Road, Shanghai 200032, China
| | - Guanghui Zhang
- Department of Occupational & Environmental Health, School of Public Health, Xinxiang Medical University, 601 Jinsui Road, Xinxiang 453003, Henan Province, China
| | - Yunxia Zhang
- Department of Occupational Health & Toxicology, School of Public Health, Shanghai Medical College of Fudan University, 130 Dongan Road, Shanghai 200032, China
| | - Yu Meng
- Department of Occupational Health & Toxicology, School of Public Health, Shanghai Medical College of Fudan University, 130 Dongan Road, Shanghai 200032, China
| | - Tongshuai Wang
- Department of Occupational Health & Toxicology, School of Public Health, Shanghai Medical College of Fudan University, 130 Dongan Road, Shanghai 200032, China
| | - Anqi Li
- Department of Occupational Health & Toxicology, School of Public Health, Shanghai Medical College of Fudan University, 130 Dongan Road, Shanghai 200032, China
| | - Junpeng Cui
- Department of Occupational & Environmental Health, School of Public Health, Xinxiang Medical University, 601 Jinsui Road, Xinxiang 453003, Henan Province, China
| | - Huan Liu
- Department of Occupational & Environmental Health, School of Public Health, Xinxiang Medical University, 601 Jinsui Road, Xinxiang 453003, Henan Province, China
| | - Weifeng Tang
- School of Public Health, Hongqiao International Institute of Medicine, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
| | - Jing Xi
- School of Public Health, Hongqiao International Institute of Medicine, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
| | - Yiyi Cao
- School of Public Health, Hongqiao International Institute of Medicine, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
| | - Yang Luan
- School of Public Health, Hongqiao International Institute of Medicine, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
| | - David C Christiani
- Environmental Medicine and Epidemiology Program, Department of Environmental Health, Harvard University TH Chan School of Public Health, Boston, MA, USA
| | - William Au
- George Emil Palade University of Medicine, Pharmacy, Science and Technology, Targu Mures, Romania, And University of Texas Medical Branch, Galveston, TX, USA
| | - Zhao-Lin Xia
- Department of Occupational Health & Toxicology, School of Public Health, Shanghai Medical College of Fudan University, 130 Dongan Road, Shanghai 200032, China.
| |
Collapse
|
3
|
Manivannan B, Kuppusamy T, Venkatesan S, Perumal V. A comparison of estimates of doses to radiotherapy patients obtained with the dicentric chromosome analysis and the γ-H2AX assay: Relevance to radiation triage. Appl Radiat Isot 2017; 131:1-7. [PMID: 29080427 DOI: 10.1016/j.apradiso.2017.10.031] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2017] [Revised: 10/14/2017] [Accepted: 10/14/2017] [Indexed: 11/18/2022]
Abstract
The γ-H2AX assay was investigated as an alternative to the time-consuming dicentric chromosome assay (DCA). Radiation doses to 25 radiotherapy patients were estimated in parallel by DCA and the γ-H2AX assay. The γ-H2AX assay yielded doses in line with the calculated equivalent whole body doses in 92% of the patients, whereas the success rate of DCA was only 76%. The result shows that the γ-H2AX assay can be effectively used as a rapid and more precise alternative to DCA.
Collapse
Affiliation(s)
- Bhavani Manivannan
- Department of Human Genetics, College of Biomedical Sciences, Technology and Research, Sri Ramachandra University, Porur, Chennai 600116, Tamil Nadu, India.
| | - Thayalan Kuppusamy
- Dr. Kamakshi Memorial Hospital Pvt. Ltd., Pallikaranai, Chennai 600100, Tamil Nadu, India.
| | - Srinivasan Venkatesan
- Dr. Kamakshi Memorial Hospital Pvt. Ltd., Pallikaranai, Chennai 600100, Tamil Nadu, India.
| | - Venkatachalam Perumal
- Department of Human Genetics, College of Biomedical Sciences, Technology and Research, Sri Ramachandra University, Porur, Chennai 600116, Tamil Nadu, India.
| |
Collapse
|