1
|
Ece E, Tasdemir HU, Biyik R, Ozmen A, Sayin U. Paramagnetic characterization and dosimetric properties of Airfix drug and its ingredients (Montelukast sodium, Sorbitol): An EPR and DFT study. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110082] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
2
|
Gallo S, Iacoviello G, Panzeca S, Veronese I, Bartolotta A, Dondi D, Gueli AM, Loi G, Longo A, Mones E, Marrale M. Characterization of phenolic pellets for ESR dosimetry in photon beam radiotherapy. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2017; 56:471-480. [PMID: 28929295 DOI: 10.1007/s00411-017-0716-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2017] [Accepted: 09/09/2017] [Indexed: 06/07/2023]
Abstract
This work deals with the dosimetric features of a particular phenolic compound (IRGANOX 1076®) for dosimetry of clinical photon beams by using electron spin resonance (ESR) spectroscopy. After the optimization of the ESR readout parameters (namely modulation amplitude and microwave power) to maximise the signal without excessive spectrum distortions, basic dosimetric properties of laboratory-made phenolic dosimeters in pellet form, such as reproducibility, dose-response, sensitivity, linearity and dose rate dependence were investigated. The dosimeters were tested by measuring the depth dose profile of a 6 MV photon beam. A satisfactory intra-batch reproducibility of the ESR signal of the manufactured dosimeters was obtained. The ESR signal proved to increase linearly with increasing dose in the investigated dose range 1-13 Gy. The presence of an intrinsic background signal limits the minimum detectable dose to a value of approximately 0.6 Gy. Reliable and accurate assessment of the dose was achieved, independently of the dose rate. Such characteristics, together with the fact that IRGANOX 1076® is almost tissue-equivalent, and the stability of the ESR signal, make these dosimeters promising materials for ESR dosimetric applications in radiotherapy.
Collapse
Affiliation(s)
- Salvatore Gallo
- Department of Physics, Università degli Studi di Milano and Istituto Nazionale di Fisica Nucleare-Sezione di Milano, Milan, Italy.
| | | | - Salvatore Panzeca
- Department of Physics and Chemistry, Università degli Studi di Palermo, Palermo, Italy
- Istituto Nazionale di Fisica Nucleare-Sezione di Catania, Catania, Italy
| | - Ivan Veronese
- Department of Physics, Università degli Studi di Milano and Istituto Nazionale di Fisica Nucleare-Sezione di Milano, Milan, Italy
| | - Antonio Bartolotta
- Department of Physics and Chemistry, Università degli Studi di Palermo, Palermo, Italy
| | - Daniele Dondi
- Department of Chemistry, Università degli Studi di Pavia and Istituto Nazionale di Fisica Nucleare-Sezione di Pavia, Pavia, Italy
| | - Anna Maria Gueli
- Istituto Nazionale di Fisica Nucleare-Sezione di Catania, Catania, Italy
- Department of Physics and Astronomy, PH3DRA Laboratories, Università degli Studi di Catania, Catania, Italy
| | - Gianfranco Loi
- Medical Physics Department, Azienda Ospedaliero Universitaria Maggiore della Carità, Novara, Italy
| | - Anna Longo
- Department of Physics and Chemistry, Università degli Studi di Palermo, Palermo, Italy
| | - Eleonora Mones
- Medical Physics Department, Azienda Ospedaliero Universitaria Maggiore della Carità, Novara, Italy
| | - Maurizio Marrale
- Department of Physics and Chemistry, Università degli Studi di Palermo, Palermo, Italy
- Istituto Nazionale di Fisica Nucleare-Sezione di Catania, Catania, Italy
- Advanced Technologies Network Center (ATeN Center), Università degli Studi di Palermo, Palermo, Italy
| |
Collapse
|