1
|
Panda M, Joshi S, Annalakshmi O, C VS, Venkatraman B. Spectroscopic and dosimetric comparison of tooth enamel separation methods for EPR retrospective dosimetry. Heliyon 2024; 10:e30571. [PMID: 38742072 PMCID: PMC11089350 DOI: 10.1016/j.heliyon.2024.e30571] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2024] [Accepted: 04/29/2024] [Indexed: 05/16/2024] Open
Abstract
Precise estimation of individual radiation dose utilizing biomaterials (fingernail, bone, and tooth) is very challenging due to their complex sample processing. Despite, tooth enamel, the most mineralized tissue of tooth is used for this purpose due to its high radiation sensitivity and ability to produce radiation induced long lived CO2- radicals. However, human teeth are not always available, and invasive nature of sample collection adds to the complexity making dose estimation difficult. In such cases, animal teeth (goat, cow, and moose) can be used as a substitute for human teeth due to comparable enamel sensitivity. Moreover, separation of enamel from dentine is a crucial step towards accurate dose estimation from irradiated teeth. In this work, Indian goat teeth were used as it was readily available to us and the comparison of goat enamel sensitivity to radiation was found to be within ∼7.4 % that of human. The enamel samples were separated following two chemical methods; (1) density separation using sodium polytungstate, (2) alkaline denaturation using NaOH and the quality was compared based on their purity and radiation sensitivity. Combined results of spectroscopic characterization using X-ray diffraction (XRD), Fourier transform infrared (FTIR), and Raman analysis authenticated the crystallinity and purity of the separated enamel samples. The radiation sensitivity of separated enamel samples was compared by electron paramagnetic resonance (EPR) analysis as a part of dosimetric characterization. The suitability of both the samples for retrospective dosimetry and epidemiological studies was checked by validating the dose estimated from separated enamel samples with standard alanine/EPR dosimeter.
Collapse
Affiliation(s)
- Madhusmita Panda
- Safety Quality and Research Management Group, IGCAR, Kalpakkam, 603102, India
| | - Shailesh Joshi
- Safety Quality and Research Management Group, IGCAR, Kalpakkam, 603102, India
| | - O. Annalakshmi
- Safety Quality and Research Management Group, IGCAR, Kalpakkam, 603102, India
- Homi Bhabha National Institute, IGCAR, Kalpakkam, 603102, India
| | - Venkata Srinivas C
- Safety Quality and Research Management Group, IGCAR, Kalpakkam, 603102, India
- Homi Bhabha National Institute, IGCAR, Kalpakkam, 603102, India
| | - B. Venkatraman
- Safety Quality and Research Management Group, IGCAR, Kalpakkam, 603102, India
- Homi Bhabha National Institute, IGCAR, Kalpakkam, 603102, India
| |
Collapse
|
2
|
Ghimire L, Waller E. Electron Paramagnetic Resonance (EPR) Biodosimetry with Human Teeth: A Crucial Technique for Acute and Chronic Exposure Assessment. HEALTH PHYSICS 2024; 126:322-338. [PMID: 38526251 DOI: 10.1097/hp.0000000000001822] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/26/2024]
Abstract
ABSTRACT Radiation exposure is a primary concern in emergency response scenarios and long-term health assessments. Accurate quantification of radiation doses is critical for informed decision-making and patient care. This paper reviews the dose reconstruction technique using both X- and Q-bands, with tooth enamel as a reliable dosimeter. Tooth enamel, due to its exceptional resistance to alteration over time, offers a unique opportunity for assessing both acute and chronic radiation exposures. This review delves into the principles underlying enamel dosimetry, the mechanism of radiation interactions, and dose retention in tooth enamel. We explore state-of-the-art analytical methods, such as electron paramagnetic resonance (EPR) spectroscopy, that accurately estimate low and high doses in acute and chronic exposure. Furthermore, we discuss the applicability of tooth enamel dosimetry in various scenarios, ranging from historical radiological incidents to recent nuclear events or radiological incidents. The ability to reconstruct radiation doses from dental enamel provides a valuable tool for epidemiological studies, validating the assessment of health risks associated with chronic exposures and aiding in the early detection and management of acute radiation incidents. This paper underscores the significance of tooth enamel as an essential medium for radiation dose reconstruction and its broader implications for enhancing radiation protection, emergency response, and public health preparedness. Incorporating enamel EPR dosimetry into standard protocols has the potential to transform the field of radiation assessment, ensuring more accurate and timely evaluations of radiation exposure and its associated risks.
Collapse
Affiliation(s)
- Lekhnath Ghimire
- Department of Energy and Nuclear Engineering, Faculty of Engineering and Applied Science, Ontario Tech University, Oshawa, ON, L1G 0C5, Canada, or email at
| | | |
Collapse
|
3
|
Wahib NB, Abdul Sani SF, Ramli A, Ismail SS, Abdul Jabar MH, Khandaker MU, Daar E, Almugren KS, Alkallas FH, Bradley DA. Natural dead sea salt and retrospective dosimetry. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2020; 59:523-537. [PMID: 32462382 DOI: 10.1007/s00411-020-00846-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Accepted: 04/29/2020] [Indexed: 06/11/2023]
Abstract
Accidents resulting in widespread dispersal of radioactive materials have given rise to a need for materials that are convenient in allowing individual dose assessment. The present study examines natural Dead Sea salt adopted as a model thermoluminescence dosimetry system. Samples were prepared in two different forms, loose-raw and loose-ground, subsequently exposed to 60Co gamma-rays, delivering doses in the range 2-10 Gy. Key thermoluminescence (TL) properties were examined, including glow curves, dose response, sensitivity, reproducibility and fading. Glow curves shapes were found to be independent of given dose, prominent TL peaks for the raw and ground samples appearing in the temperature ranges 361-385 ºC and 366-401 ºC, respectively. The deconvolution of glow curves has been undertaken using GlowFit, resulting in ten overlapping first-order kinetic glow peaks. For both sample forms, the integrated TL yield displays linearity of response with dose, the loose-raw salt showing some 2.5 × the sensitivity of the ground salt. The samples showed similar degrees of fading, with respective residual signals 28 days post-irradiation of 66% and 62% for the ground and raw forms respectively; conversely, confronted by light-induced fading the respective signal losses were 62% and 80%. The effective atomic number of the Dead Sea salt of 16.3 is comparable to that of TLD-200 (Zeff 16.3), suitable as an environmental radiation monitor in accident situations but requiring careful calibration in the reconstruction of soft tissue dose (soft tissue Zeff 7.2). Sample luminescence studies were carried out via Raman and Photoluminescence spectroscopy as well as X-ray diffraction, ionizing radiation dependent variation in lattice structure being found to influence TL response.
Collapse
Affiliation(s)
- Norfadira Binti Wahib
- Department of Physics, University of Malaya, 50603, Kuala Lumpur, Malaysia
- Centre for Biomedical Physics, School of Healthcare and Medical Sciences, Sunway University, 47500, Bandar Sunway, Selangor, Malaysia
| | - S F Abdul Sani
- Department of Physics, University of Malaya, 50603, Kuala Lumpur, Malaysia.
| | - Ain Ramli
- Department of Physics, University of Malaya, 50603, Kuala Lumpur, Malaysia
| | - S S Ismail
- Department of Physics, University of Malaya, 50603, Kuala Lumpur, Malaysia
| | | | - M U Khandaker
- Department of Physics, University of Malaya, 50603, Kuala Lumpur, Malaysia
- Centre for Biomedical Physics, School of Healthcare and Medical Sciences, Sunway University, 47500, Bandar Sunway, Selangor, Malaysia
| | - E Daar
- Department of Physics, The University of Jordan, Amman, 11942, Jordan
| | - K S Almugren
- Department of Physics, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia
| | - F H Alkallas
- Department of Physics, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia
| | - D A Bradley
- Centre for Biomedical Physics, School of Healthcare and Medical Sciences, Sunway University, 47500, Bandar Sunway, Selangor, Malaysia
- Department of Physics, University of Surrey, Guildford, Surrey, GU2 7XH, UK
| |
Collapse
|