1
|
Rey Gomez LM, Hirani R, Care A, Inglis DW, Wang Y. Emerging Microfluidic Devices for Sample Preparation of Undiluted Whole Blood to Enable the Detection of Biomarkers. ACS Sens 2023; 8:1404-1421. [PMID: 37011238 DOI: 10.1021/acssensors.2c02696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2023]
Abstract
Blood testing allows for diagnosis and monitoring of numerous conditions and illnesses; it forms an essential pillar of the health industry that continues to grow in market value. Due to the complex physical and biological nature of blood, samples must be carefully collected and prepared to obtain accurate and reliable analysis results with minimal background signal. Examples of common sample preparation steps include dilutions, plasma separation, cell lysis, and nucleic acid extraction and isolation, which are time-consuming and can introduce risks of sample cross-contamination or pathogen exposure to laboratory staff. Moreover, the reagents and equipment needed can be costly and difficult to obtain in point-of-care or resource-limited settings. Microfluidic devices can perform sample preparation steps in a simpler, faster, and more affordable manner. Devices can be carried to areas that are difficult to access or that do not have the resources necessary. Although many microfluidic devices have been developed in the last 5 years, few were designed for the use of undiluted whole blood as a starting point, which eliminates the need for blood dilution and minimizes blood sample preparation. This review will first provide a short summary on blood properties and blood samples typically used for analysis, before delving into innovative advances in microfluidic devices over the last 5 years that address the hurdles of blood sample preparation. The devices will be categorized by application and the type of blood sample used. The final section focuses on devices for the detection of intracellular nucleic acids, because these require more extensive sample preparation steps, and the challenges involved in adapting this technology and potential improvements are discussed.
Collapse
Affiliation(s)
| | - Rena Hirani
- Australian Red Cross Lifeblood, Sydney, New South Wales 2015, Australia
| | - Andrew Care
- School of Life Sciences, University of Technology Sydney, Ultimo, New South Wales 2007, Australia
| | - David W Inglis
- School of Engineering, Faculty of Science and Engineering and △School of Natural Sciences, Faculty of Science and Engineering, Macquarie University, Sydney, New South Wales 2109, Australia
| | | |
Collapse
|
2
|
Biggin MR, Albrecht I, Novroski NM. Assessing DNA recovery and profile determination from bloody snow. Sci Justice 2022; 62:152-155. [DOI: 10.1016/j.scijus.2022.01.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Revised: 01/01/2022] [Accepted: 01/12/2022] [Indexed: 11/16/2022]
|
4
|
Analytical validation of an RI sample cartridge with the RapidHIT® ID system. Int J Legal Med 2021; 135:1257-1265. [PMID: 33754178 DOI: 10.1007/s00414-021-02553-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Accepted: 02/24/2021] [Indexed: 10/21/2022]
Abstract
Evaluating the short tandem repeat (STR) in the field is important for the timely identification of a suspect. Several lines showed that the RapidHIT® ID system is reliable for DNA genotyping with buccal swabs and naked DNA. However, the application of this approach with blood samples has been poorly investigated. Because blood samples are among the most common forensic samples in our laboratory, further studies should be conducted. Here, we assessed the analytical performance of 19 STR loci with a newly developed RapidINTEL (RI) Sample Cartridge Kit by using the blood samples with known genotypes. Several commonly used substrates were included in the sensitivity study, and FTA cards proved to be the most promising sample carrier for blood storage and later identification. There was superior sensitivity and specificity with a 100% concordance rate for 0.5 μL of blood or 7 ng of genomic DNA. The performance for blood samples was comparable with that for the standard protocol. High success rate (90.57%) and high-concordance (100%) genotyping were automatically achieved over a wide range of operating conditions except for TH01. No contamination was observed throughout the study. Hematin, indigo, and humic acid had limited influence on the instrument system, while urea and melanin dramatically affected the genotyping results. Generally, the newly developed RI sample cartridge provided an alternative method for the STR genotyping of single-source blood samples over a wide range of operating conditions.
Collapse
|
5
|
Moretti M, Manfredi A, Freni F, Previderé C, Osculati AMM, Grignani P, Tronconi L, Carelli C, Vignali C, Morini L. A comparison between two different dried blood substrates in determination of psychoactive substances in postmortem samples. Forensic Toxicol 2021; 39:385-393. [PMID: 33488834 PMCID: PMC7812343 DOI: 10.1007/s11419-020-00567-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 11/20/2020] [Indexed: 11/01/2022]
Abstract
Purpose Whatman™ 903 cards represent a valid type of support for collection, storage, and analysis of dried blood spots (DBS). Whatman™ FTA (Flinders Technology Associates) are a type of cards soaked in chemicals that cause denaturation of proteins, while preserving DNA and ensuring the safe handling of DBS; to date, these cards are still rarely employed in forensic toxicology. The aim of this study was to analyze several psychoactive substances on not-dried blood on the two different cards and to compare the qualitative and quantitative results. Methods Twenty cardiac postmortem blood samples were collected and deposed on Whatman™ 903 and Whatman™ FTA cards. Spots and not-dried blood were analyzed following our validated and previously published liquid chromatography-mass spectrometry methods. Results We were able to identify: eight drugs of abuse and their metabolites (15 cases), five benzodiazepines and their metabolites (3 cases), six antidepressants (6 cases) and two antipsychotics (3 cases). We observed a perfect qualitative correspondence and a general good quantitative correlation between data obtained from not-dried blood and the two different DBS cards, except for alprazolam, diazepam, desmethyldiazepam, fluoxetine and sertraline, that showed a lower concentration on FTA. Additional experiments suggest that the chemicals, adsorbed on FTA, are not the cause of the loss of signal observed for the substances previously mentioned and that methanol should be preferred as extraction solvent. Conclusions This study proved that FTA cards are a good and a hazard-free alternative sample storage method for analysis of several psychoactive substances in postmortem blood. Supplementary Information The online version contains supplementary material available at 10.1007/s11419-020-00567-2.
Collapse
Affiliation(s)
- Matteo Moretti
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, via Forlanini 12, Pavia, Italy
| | - Alessandro Manfredi
- Department of Medicine, Surgery and Health, University of Trieste, Piazzale Europa 1, Trieste, Italy
| | - Francesca Freni
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, via Forlanini 12, Pavia, Italy
| | - Carlo Previderé
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, via Forlanini 12, Pavia, Italy
| | - Antonio Marco Maria Osculati
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, via Forlanini 12, Pavia, Italy.,Legal Medicine Operative Unit, IRCCS Fondazione Mondino, Pavia, Via Mondino 2, 27100 Pavia, PV Italy
| | - Pierangela Grignani
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, via Forlanini 12, Pavia, Italy
| | - Livio Tronconi
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, via Forlanini 12, Pavia, Italy.,Legal Medicine Operative Unit, IRCCS Fondazione Mondino, Pavia, Via Mondino 2, 27100 Pavia, PV Italy
| | - Claudia Carelli
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, via Forlanini 12, Pavia, Italy
| | - Claudia Vignali
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, via Forlanini 12, Pavia, Italy
| | - Luca Morini
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, via Forlanini 12, Pavia, Italy
| |
Collapse
|
6
|
Quantifying visible absorbance changes and DNA degradation in aging bloodstains under extreme temperatures. Forensic Sci Int 2020; 318:110627. [PMID: 33296804 DOI: 10.1016/j.forsciint.2020.110627] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Revised: 11/19/2020] [Accepted: 11/23/2020] [Indexed: 01/28/2023]
Abstract
Physicochemical property changes observed in a degrading bloodstain can be used to estimate its time since deposition (TSD) and provide a timestamp to the sample's age. Many of the time-dependent processes that occur as a bloodstain degrades, such as DNA fragmentation and changes in hemoglobin structure, also exhibit temperature-dependent behaviours. Previous studies have demonstrated that pairing high-resolution automated gel electrophoresis and visible absorbance spectroscopy could be used to quantify the rate of degradation of a bloodstain in relation to time and storage substrate. Our study investigates such trends with an added factor, extreme temperatures. Passive drip stains were stored in either microcentrifuge tubes or on FTA cards at either -20°C, 21°C or 40°C and tested over 11 time points spanning 15 days. For both storage substrates, the wavelength at maximum absorbance for the Soret band and the maximum absorbance of the Alpha band showed a negative trend over time suggesting that spectral shifts are informative for TSD estimates. The ratio of the maximum peak height for DNA fragments lengths of 500-1000 base pairs to 1000-5000 base pairs was the most informative DNA variable in relation to time for both substrates. Cross-validation suggested the appropriate fit of the models with the data and reasonable predictive ability. We integrated both DNA concentration and hemoglobin visible absorbance metrics using principal component analysis (PCA) into a single model. Adding the random effect of the donor to the PCA model accounted for a large portion of the variation as did storage method and temperature. Additionally, canonical correspondence showed that temperature corresponded differently to the response variables for FTA card and microcentrifuge tube samples, suggesting a substrate specific effect. This study confirms that pairing DNA concentration and hemoglobin's visible absorbance can provide insight on the effect of different environmental and storage conditions on bloodstain degradation. While the level of uncertainty surrounding TSD estimates still precludes its use in the field, this study provides a valuable framework that improves our understanding of variation surrounding TSD estimates, which will be critical to any eventual application.
Collapse
|
7
|
Shalaby AG, Bakry NR, Mohamed AAE, Khalil AA. Evaluating Flinders Technology Associates card for transporting bacterial isolates and retrieval of bacterial DNA after various storage conditions. Vet World 2020; 13:2243-2251. [PMID: 33281363 PMCID: PMC7704315 DOI: 10.14202/vetworld.2020.2243-2251] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2020] [Accepted: 09/21/2020] [Indexed: 11/16/2022] Open
Abstract
Background and Aim: Flinders Technology Associates (FTA) cards simplify sample storage, transport, and extraction by reducing cost and time for diagnosis. This study evaluated the FTA suitability for safe transport and storage of Gram-positive and Gram-negative bacterial cells of animal origin on its liquid culture form and from organ impression smears (tissues) under the same routine condition of microbiological laboratory along with detecting their nucleic acid over different storage conditions. Materials and Methods: Increase in bacterial count from 104 to 107 (colony-forming units/mL) of 78 isolates representing seven bacterial species was applied onto cards. FTA cards were grouped and inoculated by these bacteria and then stored at different conditions of 24-27°C, 4°C, and −20°C for 24 h, for 2 weeks, for 1 and 3 month storage, respectively. Bacteriological examination was done, after which bacterial DNA was identified using specific primers for each bacterial type and detected by polymerase chain reaction (PCR). Results: The total percentage of recovered bacteria from FTA cards was 66.7% at 24-27°C for 24 h, the detection limit was 100% in Gram-positive species, while it was 57.4% in Gram-negative ones. Regarding viable cell detection from organ impression smears, it was successful under the previous conditions. No live bacterial cells were observed by bacteriological isolation rather than only at 24-27°C for 24 h storage. All bacterial DNA were sufficiently confirmed by the PCR technique at different conditions. Conclusion: Overall, the FTA card method was observed to be a valid tool for nucleic acid purification for bacteria of animal origin in the form of culture or organ smears regardless of its Gram type and is used for a short time only 24 h for storage and transport of live bacteria specifically Gram-positive type. Moreover, the bacterial nucleic acid was intact after storage in −20°C for 3 months and was PCR amplifiable.
Collapse
Affiliation(s)
- Azhar G Shalaby
- Department of Biotechnology Unit, Reference Laboratory for Veterinary Quality Control on Poultry Production, Animal Health Research Institute, Agricultural Research Centre, Dokki, Giza, Egypt
| | - Neveen R Bakry
- Department of Epidemiology Unit, Reference Laboratory for Veterinary Quality Control on Poultry Production, Animal Health Research Institute, Agricultural Research Centre, Dokki, Giza, Egypt
| | - Abeer A E Mohamed
- Department of Buffalo Diseases, Animal Health Research Institute, Dokki, Giza, Egypt
| | - Ashraf A Khalil
- Institute of Biotechnology and Genetic Engineering, City of Scientific Research and Technology Applications, Borg Elarab, Alexandria, Egypt
| |
Collapse
|
8
|
The importance of forensic storage support: DNA quality from 11-year-old saliva on FTA cards. Int J Legal Med 2019; 133:1743-1750. [PMID: 31463575 DOI: 10.1007/s00414-019-02146-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Accepted: 08/14/2019] [Indexed: 10/26/2022]
Abstract
Storage conditions influence the integrity of the recoverable DNA from forensic evidence in terms of yield and quality. FTA cards are widely used in the forensic practice as their chemically treated matrix provides protection from the moment of collection to the point of analysis with current STR typing technology. In this study, we assess the recoverability and the integrity of DNA from 11-year-old saliva on FTA cards using a forensic quantitative real-time polymerase chain reaction (qPCR) commercial assay. The quality after long-term storage was investigated in order to evaluate if the FTA device could assure enough stability over time, applying some internally validated quality criteria of the STR profile. Furthermore, we used a 3D interpolation model to combine the quantitative and qualitative data from qPCR to calculate the minimum optimal DNA input (MODI) to add to the downstream PCR reaction based on the quantitative and qualitative data of a sample. According to our results, when saliva sample is properly transferred onto FTA cards and then correctly stored according to the manufacturer's instructions, it is possible to recover sufficient amounts of DNA for human identification even after more than a decade of storage at ambient temperature. Degradation affected the quality of results especially when the Degradation Index exceeds the value of 2.12, requiring modifications of the standard internal workflow to improve the genotyping quality. Above this value, the application of a "corrective factor" to the PCR normalization process was necessary in order to adjust the recommended manufacturer's PCR DNA input taking into account the degradation level. Our results demonstrated the importance to consider in predictive terms the parameters obtained with the real-time quantification assay, both in terms of quantity (DNA concentration) and of quality (DI, inhibition). Informatics predictive tools including qPCR data together with the variables of storage duration and conditions should be developed in order to optimize the DNA analysis process.
Collapse
|