1
|
García-Santamaría A, Abelairas-Gómez C, Carrera S, Padrón-Cabo A, Rey E. Effects of maturation on myotonometric parameters and their predictors of athletic performance in elite youth soccer players. Sci Rep 2024; 14:12287. [PMID: 38811805 PMCID: PMC11137063 DOI: 10.1038/s41598-024-63224-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Accepted: 05/27/2024] [Indexed: 05/31/2024] Open
Abstract
The aim of the present study was to investigate the variations in individual muscle stiffness across different maturation stages (i.e., peak height velocity [PHV]) in elite youth soccer players and to explore the associations between lower limb muscle stiffness and performance in sprinting (10, 20, and 40 m sprint), maneuverability (9-3-6-3-9 m sprint test), and jumping (countermovement jump [CMJ]). A total of 131 elite youth soccer players aged 12-18 years, volunteered to participate in the study and were divided into pre-PHV (n = 21), mid-PHV (n = 33), and post-PHV (n = 80). Muscle stiffness of the rectus femoris (RF) and biceps femoris (BF) muscles was assessed using a MyotonPRO. Results showed that players in the pre-PHV stage had lower stiffness in the BF and RF muscles compared to mid-PHV (p < 0.001; effect size [ES] = moderate to large) and post-PHV players (p < 0.001; ES = moderate to large). It was also observed that the mid-PHV group had lower stiffness levels in their RF muscle compared to the post-PHV group (p < 0.001; ES = small). Significant correlations were found between BF and RF stiffness and sprint (p < 0.001) and maneuverability (p < 0.001) performance. RF stiffness showed a significant positive correlation with CMJ (p < 0.05), suggesting that greater lower body stiffness is beneficial for athletic performance in youth soccer players. The findings highlighting the importance of considering training methods that increase muscular stiffness, particularly in relation to the RF muscle, to optimize athletic performance.
Collapse
Affiliation(s)
| | - Cristian Abelairas-Gómez
- Faculty of Education Sciences, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
| | - Samuel Carrera
- Faculty of Education and Sport Sciences, University of Vigo, Pontevedra, Spain
| | - Alexis Padrón-Cabo
- Faculty of Education and Sport Sciences, University of Vigo, Pontevedra, Spain
| | - Ezequiel Rey
- Faculty of Education and Sport Sciences, University of Vigo, Pontevedra, Spain.
| |
Collapse
|
2
|
Garzón-Alfaro MT, Cruz-Medel I, Alcaraz-Clariana S, García-Luque L, Carmona-Pérez MC, Garrido-Castro JL, Alburquerque-Sendín F, Rodrigues-de-Souza DP. Influence of vaginal birth on lumbopelvic muscle mechanical properties on urinary incontinence. Clin Rehabil 2024; 38:558-568. [PMID: 38295335 DOI: 10.1177/02692155231224058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2024]
Abstract
OBJECTIVE To identify differences in the muscle mechanical properties of the pelvic floor (PF) and lumbar paravertebral (LP) muscles between young nulliparous and uni/multiparous women. Secondarily, specific behaviors, depending on the presence or absence or urinary incontinence (UI), were also researched. DESIGN Case-control study. SETTING Higher education institution. PARTICIPANTS One hundred young women participated, divided into two groups depending on whether they had vaginal birth (nulliparous or uni/multiparous). Each group included women with and without UI. MAIN MEASURES A muscle mechanical properties (tone, stiffness, decrement-inverse of elasticity-, and viscoelastic properties: relaxation and creep) assessment of the PF and LP muscles were performed with a hand-held tonometer. RESULTS Tone and stiffness of both sides of the PF presented group by UI interaction (p < 0.05), with uni/multiparous women with UI showing higher tone and stiffness compared to multiparous women without UI. In LP muscles, uni/multiparous women showed greater tone and stiffness on the right and left sides [-2.57 Hz (95% confidence interval -4.42,-0.72) and -79.74 N/m (-143.52,-15.97); -2.20 Hz (-3.82,-0.58) and -81.30 N/m (-140.66-,21.95), respectively], as well as a decrease in viscoelastic properties compared to nulliparous women [relaxation: 2.88 ms (0.31,5.44); creep: 0.15 (0.01,0.30); relaxation: 2.69 ms (0.13,5.25); creep: 0.14 (0,0.28), respectively]. CONCLUSIONS Vaginal birth and UI have a differential influence on the muscle mechanical properties of the PF and LP muscles. The determination of muscle mechanical properties by externally applied hand-held tonometry improves the knowledge of the lumbopelvic status, with applicability in clinical and research fields.
Collapse
Affiliation(s)
- María Teresa Garzón-Alfaro
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, Córdoba, Spain
| | - Inés Cruz-Medel
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, Córdoba, Spain
| | - Sandra Alcaraz-Clariana
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, Córdoba, Spain
| | - Lourdes García-Luque
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, Córdoba, Spain
| | - María Cristina Carmona-Pérez
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, Córdoba, Spain
| | - Juan Luis Garrido-Castro
- Department of Computer Science and Numerical Analysis, Rabanales Campus, University of Córdoba, Córdoba, Spain
- GC05 Systemic and chronic inflammatory autoimmune diseases of the locomotor system and connective tissue, Maimonides Biomedical Research Institute of Cordoba (IMIBIC), Córdoba, Spain
| | - Francisco Alburquerque-Sendín
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, Córdoba, Spain
- GC05 Systemic and chronic inflammatory autoimmune diseases of the locomotor system and connective tissue, Maimonides Biomedical Research Institute of Cordoba (IMIBIC), Córdoba, Spain
| | - Daiana Priscila Rodrigues-de-Souza
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, Córdoba, Spain
- GC05 Systemic and chronic inflammatory autoimmune diseases of the locomotor system and connective tissue, Maimonides Biomedical Research Institute of Cordoba (IMIBIC), Córdoba, Spain
| |
Collapse
|
3
|
Brandl A, Acikalin E, Bartsch K, Wilke J, Schleip R. Reliability and validity of an app-assisted tissue compliance meter in measuring tissue stiffness on a phantom model. PeerJ 2024; 12:e17122. [PMID: 38464760 PMCID: PMC10924762 DOI: 10.7717/peerj.17122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Accepted: 02/26/2024] [Indexed: 03/12/2024] Open
Abstract
Background Most methods for soft tissue stiffness assessment require high financial resources, significant technical effort, or extensive therapist training. The PACT Sense device was developed to be used in a wide range of applications and user groups. However, to date, there are no data on its validity and reliability. The aim of this study was to investigate the validity and reliability of the PACT device. Methods A polyurethane phantom tissue model (PTM) mimicking the mechanical properties of the fascia profunda and the erector spinae muscle was used. Stiffness measurements with PACT were conducted by two independent investigators. For construct validity, correlations were calculated between the known stiffness of the PTM and values obtained with PACT. For concurrent validity, we determined the association between the PACT values and additional measurements with the established MyotonPRO device. To estimate interrater and intrarater (two measurements with an interval of 7 days) reliability, we used the intraclass correlation coefficient (ICC). Results Correlation analysis (PTM/PACT) revealed very high concurrent validity (r = 0.99; p < 0.001), construct validity (PACT/MyotonPRO) was 0.87, p < 0.001. Both, interrater reliability (ICC = 0.85; p = 0.036) and intrarater reliability were good (ICC = 0.89; p < 0.001). Conclusions The PACT provides valid and reliable stiffness measurements in tissue phantoms. Further studies in humans are needed to confirm its physiometric properties under in vivo conditions.
Collapse
Affiliation(s)
- Andreas Brandl
- Department of Sports Medicine, Institute for Human Movement Science, Faculty for Psychology and Human Movement Science, University of Hamburg, Hamburg, Germany
- Department of Sport and Health Sciences, Conservative and Rehabilitative Orthopedics, Technical University of Munich, Munich, Germany
- Department for Medical Professions, Diploma Hochschule, Bad Sooden-Allendorf, Germany
| | - Eda Acikalin
- Department of Sport and Health Sciences, Conservative and Rehabilitative Orthopedics, Technical University of Munich, Munich, Germany
- Faculty of Physical Therapy and Rehabilitation, Hacettepe University, Ankara, Turkey
| | - Katja Bartsch
- Department of Sport and Health Sciences, Conservative and Rehabilitative Orthopedics, Technical University of Munich, Munich, Germany
- Department of Sport Science and Sport, Friedrich-Alexander Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Jan Wilke
- Department of Movement Sciences, University of Klagenfurt, Klagenfurt, Austria
| | - Robert Schleip
- Department of Sport and Health Sciences, Conservative and Rehabilitative Orthopedics, Technical University of Munich, Munich, Germany
- Department for Medical Professions, Diploma Hochschule, Bad Sooden-Allendorf, Germany
| |
Collapse
|
4
|
McGowen JM, Hoppes CW, Forsse JS, Albin SR, Abt J, Koppenhaver SL. Myotonometry is Capable of Reliably Obtaining Trunk and Thigh Muscle Stiffness Measures in Military Cadets During Standing and Squatting Postures. Mil Med 2024; 189:e213-e219. [PMID: 37208314 DOI: 10.1093/milmed/usad179] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 04/19/2023] [Accepted: 05/04/2023] [Indexed: 05/21/2023] Open
Abstract
INTRODUCTION Low back and lower extremity injuries are responsible for the highest percentage of musculoskeletal injuries in U.S. Army soldiers. Execution of common soldier tasks as well as army combat fitness test events such as the three-repetition maximum deadlift depends on healthy functioning trunk and lower extremity musculature to minimize the risk of injury. To assist with appropriate return to duty decisions following an injury, reliable and valid tests and measures must be applied by military health care providers. Myotonometry is a noninvasive method to assess muscle stiffness, which has demonstrated significant associations with physical performance and musculoskeletal injury. The aim of this study is to determine the test-retest reliability of myotonometry in lumbar spine and thigh musculature across postures (standing and squatting) that are relevant to common soldier tasks and the maximum deadlift. MATERIALS AND METHODS Repeat muscle stiffness measures were collected in 30 Baylor University Army Cadets with 1 week between each measurement. Measures were collected in the vastus lateralis (VL), biceps femoris (BF), lumbar multifidus (LM), and longissimus thoracis (LT) muscles with participants in standing and squatting positions. Intraclass correlation coefficients (ICCs3,2) were estimated, and their 95% CIs were calculated based on a mean rating, mixed-effects model. RESULTS The test-retest reliability (ICC3,2) of the stiffness measures was good to excellent in all muscles across the standing position (ICCs: VL = 0.94 [0.87-0.97], BF = 0.97 [0.93-0.98], LM = 0.96 [0.91-0.98], LT = 0.81 [0.59-0.91]) and was excellent in all muscles across the squatting position (ICCs: VL = 0.95 [0.89-0.98], BF = 0.94 [0.87-0.97], LM = 0.96 [0.92-0.98], LT = 0.93 [0.86-0.97]). CONCLUSION Myotonometry can reliably acquire stiffness measures in trunk and lower extremity muscles of healthy individuals in standing and squatting postures. These results may expand the research and clinical applications of myotonometry to identify muscular deficits and track intervention effectiveness. Myotonometry should be used in future studies to investigate muscle stiffness in these body positions in populations with musculoskeletal injuries and in research investigating the performance and rehabilitative intervention effectiveness.
Collapse
Affiliation(s)
- Jared M McGowen
- Department of Health, Human Performance, and Recreation, Baylor University, One Bear Place, Waco, TX 76798, USA
| | - Carrie W Hoppes
- Doctoral Program in Physical Therapy, Army-Baylor University, Joint Base San Antonio, Fort Sam Houston, TX 78234, USA
| | - Jeff S Forsse
- Department of Health, Human Performance, and Recreation, Baylor University, One Bear Place, Waco, TX 76798, USA
| | | | - John Abt
- Children's Health Andrews Institute for Orthopaedics and Sports Medicine, Plano, TX 75024, USA
| | - Shane L Koppenhaver
- Department of Health, Human Performance, and Recreation, Baylor University, One Bear Place, Waco, TX 76798, USA
- Doctoral Program in Physical Therapy, Baylor University, One Bear Place, Waco, TX 76798, USA
| |
Collapse
|
5
|
Rodrigues-de-Souza DP, Casas-Castro A, Carmona-Pérez MC, García-Luque L, Alcaraz-Clariana S, Garrido-Castro JL, Alburquerque-Sendín F. Between-sexes differences in lumbopelvic muscle mechanical properties of non-climacteric adults: a cross-sectional design. Sci Rep 2023; 13:21612. [PMID: 38062151 PMCID: PMC10703780 DOI: 10.1038/s41598-023-48984-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Accepted: 12/02/2023] [Indexed: 12/18/2023] Open
Abstract
The lumbopelvic muscle mechanical properties (MMPs) are clinically relevant, but their dependence on sex remains unknown. Therefore, this study aimed to identify if lumbopelvic MMPs depend on the sex in a young adult population. Thirty-five healthy nulliparous women and 35 healthy men were analyzed (age range: 18-50). Lumbopelvic MMPs, that is, tone, stiffness, elasticity, relaxation and creep, assessed with MyotonPRO®, and pelvic floor (PF) health questionnaires were compared between-sexes. Intra-group correlations between sociodemographic and clinical data, and MMPs were also determined. The MMPs of PF were different between healthy non-climacteric adults of both sexes, with women showing higher values of tone and stiffness and lower values of elasticity and viscoelastic properties than men (in all cases, p < 0.03). At lumbar level, tone and stiffness were higher for men at both sides (in all cases, p < 0.04), and relaxation was lower at left side (p = 0.02). The MMPs showed few correlations with sociodemographic data within women. However, within males, there were positive correlations for PF stiffness and viscoelastic parameters with age, BMI and function (0.334 < r < 0.591) and, at lumbar level, negative correlations for tone and stiffness ( - 0.385 < r < -0.590) and positive correlations for viscoelastic properties (0.564 < r < 0.719), with BMI. This indicated that between-sexes differences of lumbopelvic MMPs depend on the specific location of assessment in healthy non-obese young individuals. Women show higher tone and stiffness and lower elasticity and viscoelasticity than men, at PF level.
Collapse
Affiliation(s)
- Daiana Priscila Rodrigues-de-Souza
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004, Córdoba, Spain
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004, Córdoba, Spain
| | - Azahara Casas-Castro
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004, Córdoba, Spain
| | - María Cristina Carmona-Pérez
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004, Córdoba, Spain
| | - Lourdes García-Luque
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004, Córdoba, Spain
| | - Sandra Alcaraz-Clariana
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004, Córdoba, Spain
| | - Juan Luis Garrido-Castro
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004, Córdoba, Spain
- Department of Computer Science and Numerical Analysis, Rabanales Campus, University of Córdoba, 14071, Córdoba, Spain
| | - Francisco Alburquerque-Sendín
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004, Córdoba, Spain.
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004, Córdoba, Spain.
| |
Collapse
|
6
|
Mesquita RNO, Latella C, Ruas CV, Nosaka K, Taylor JL. Contraction Velocity of the Elbow Flexors Assessed by Tensiomyography: A Comparison Between Formulas. J Strength Cond Res 2023; 37:1969-1977. [PMID: 36946988 DOI: 10.1519/jsc.0000000000004495] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 12/15/2022] [Indexed: 03/23/2023]
Abstract
ABSTRACT Mesquita, RNO, Latella, C, Ruas, CV, Nosaka, K, and Taylor, JL. Contraction velocity of the elbow flexors assessed by tensiomyography: A comparison between formulas. J Strength Cond Res 37(10): 1969-1977, 2023-Muscle contraction velocity ( Vc ) assessed by tensiomyography is a promising measure for athlete profiling. Multiple formulas are used to estimate Vc , but the most suitable method is yet to be established. Fifteen adults (2 female subjects) underwent tensiomyography assessment of biceps brachii muscle at 10, 45 and 90° of elbow flexion on 2 separate days. Vc was calculated using 6 formulas. Formulas 1 and 2 are measures of the early phase of the twitch; Formulas 3-5 are measures over a wider time-window, with Formula 5 normalizing Vc to maximal displacement ( D m); and we proposed Formula 6 as a measure of peak Vc . Test-retest reliability, the required minimum number of trials, proportional bias, and effects of joint angle were investigated. Higher reliability (coefficient of variation: 2.8-6.9%) was found for Formula 1 (0-2 mm of displacement) and Formula 5 (normalized 10-90% of D m). Overall, a minimum of 6-7 trials was required to obtain reliable estimates. For 10° only, significant positive proportional bias ( r = 0.563-0.670) was found for all formulas except Formula 5. Vc was faster ( p < 0.001) at shorter muscle lengths for all formulas except Formula 5 ( p = 0.06). Vc in the early phase of the twitch was more reliable when calculated using absolute displacement (Formula 1) than a relative threshold (Formula 2). Over a larger time-window, Formulas 3 and 4 were similarly reliable. Because they are derived from different components of the twitch and different parameters, the different formulas should not be used interchangeably. Additionally, more precise nomenclature is required to describe the information obtained from each formula.
Collapse
Affiliation(s)
- Ricardo N O Mesquita
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden
- School of Medical and Health Sciences, Centre for Human Performance, Edith Cowan University, Perth, Australia
- Neuroscience Research Australia, Sydney, Australia; and
| | - Christopher Latella
- School of Medical and Health Sciences, Centre for Human Performance, Edith Cowan University, Perth, Australia
| | - Cassio V Ruas
- School of Medical and Health Sciences, Centre for Human Performance, Edith Cowan University, Perth, Australia
- Brazilian Institute of Neuroscience and Neurotechnology-Institute of Physics Gleb Wataghin, University of Campinas, São Paulo, Brazil
| | - Kazunori Nosaka
- School of Medical and Health Sciences, Centre for Human Performance, Edith Cowan University, Perth, Australia
| | - Janet L Taylor
- School of Medical and Health Sciences, Centre for Human Performance, Edith Cowan University, Perth, Australia
- Neuroscience Research Australia, Sydney, Australia; and
| |
Collapse
|
7
|
Deodato M, Saponaro S, Šimunič B, Martini M, Murena L, Buoite Stella A. Trunk muscles' characteristics in adolescent gymnasts with low back pain: a pilot study on the effects of a physiotherapy intervention including a postural reeducation program. J Man Manip Ther 2023:1-15. [PMID: 37649443 DOI: 10.1080/10669817.2023.2252202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Accepted: 08/20/2023] [Indexed: 09/01/2023] Open
Abstract
BACKGROUND Trunk muscles' function and characteristics are of great importance for both static and dynamic tasks in different sports, and abnormalities of trunk flexors and extensors might be associated with low back pain (LBP). The aim of this study was to provide a comprehensive evaluation of the functional, morphological and contractile properties in trunk flexors and extensors of young gymnasts with and without LBP. METHODS Young gymnasts (14/25 females, 14-18 y) were screened for the presence of chronic LBP. Abdominal and lumbar muscles were tested for function (McGill's endurance tests), thickness (ultrasound), and contractile responses (tensiomyography). An 8-sessions physiotherapy intervention including postural reeducation was performed by a subsample of 10 subjects with LBP. RESULTS LBP was found to be associated to higher flexors-to-extensors endurance ratio (OR 11.250, 95% CI: 1.647-76.849, p = 0.014), reduced mean lumbar multifidus thickness (OR 16.500, 95% CI: 2.246-121.228, p = 0.006), and reduced mean erector spinae radial displacement (OR 16.500, 95% CI: 2.246-121.228, p = 0.006). The physiotherapy intervention was found to reduce LBP symptoms and it was associated with a significant improvement in the flexors-to-extensors ratio (p < 0.001). CONCLUSIONS This study provides preliminary evidence of functional, morphological, and contractile trunk muscles' alterations associated with chronic LBP in young gymnasts, and presents the effects of a postural reeducation program on symptoms and muscles' functional properties.
Collapse
Affiliation(s)
- Manuela Deodato
- School of Physiotherapy, Department of Medicine, Surgery and Health Sciences, University of Trieste, Trieste, Italy
- PhD Program in Neural and Cognitive Sciences, Department of Life Sciences, University of Trieste, Trieste, Italy
| | - Serena Saponaro
- School of Physiotherapy, Department of Medicine, Surgery and Health Sciences, University of Trieste, Trieste, Italy
| | - Boštjan Šimunič
- Institute for Kinesiology Research, Science and Research Center of Koper, Koper, Slovenia
| | - Miriam Martini
- School of Physiotherapy, Department of Medicine, Surgery and Health Sciences, University of Trieste, Trieste, Italy
| | - Luigi Murena
- School of Physiotherapy, Department of Medicine, Surgery and Health Sciences, University of Trieste, Trieste, Italy
- Orthopaedics and Traumatology Unit, Cattinara Hospital - ASUGI, Department of Medicine, Surgery and Health Sciences, University of Trieste, Trieste, Italy
| | - Alex Buoite Stella
- School of Physiotherapy, Department of Medicine, Surgery and Health Sciences, University of Trieste, Trieste, Italy
| |
Collapse
|
8
|
Kopecká B, Ravnik D, Jelen K, Bittner V. Objective Methods of Muscle Tone Diagnosis and Their Application-A Critical Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:7189. [PMID: 37631726 PMCID: PMC10458714 DOI: 10.3390/s23167189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2023] [Revised: 08/09/2023] [Accepted: 08/10/2023] [Indexed: 08/27/2023]
Abstract
"Muscle tone" is a clinically important and widely used term and palpation is a crucial skill for its diagnosis. However, the term is defined rather vaguely, and palpation is not measurable objectively. Therefore, several methods have been developed to measure muscle tone objectively, in terms of biomechanical properties of the muscle. This article aims to summarize these approaches. Through database searches, we identified those studies related to objective muscle tone measurement in vivo, in situ. Based on them, we described existing methods and devices and compared their reliability. Furthermore, we presented an extensive list of the use of these methods in different fields of research. Although it is believed by some authors that palpation cannot be replaced by a mechanical device, several methods have already proved their utility in muscle biomechanical property diagnosis. There appear to be two issues preventing wider usage of these objective methods in clinical practice. Firstly, a high variability of their reliability, and secondly, a lack of valid mathematical models that would provide the observed mechanical characteristics with a clear physical significance and allow the results to be compared with each other.
Collapse
Affiliation(s)
- Barbora Kopecká
- Faculty of Physical Education and Sport, Charles University, 162 52 Prague, Czech Republic
| | - David Ravnik
- Faculty of Health Sciences, University of Primorska, 6310 Izola, Slovenia
| | - Karel Jelen
- Faculty of Physical Education and Sport, Charles University, 162 52 Prague, Czech Republic
| | - Václav Bittner
- Faculty of Science, Humanities and Education, Technical University of Liberec, 461 17 Liberec, Czech Republic
| |
Collapse
|
9
|
Langen G, Lohr C, Ueberschär O, Behringer M. Reproducibility of knee extensor and flexor contraction velocity in healthy men and women assessed using tensiomyography: A registered report. PLoS One 2023; 18:e0288806. [PMID: 37531344 PMCID: PMC10395843 DOI: 10.1371/journal.pone.0288806] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2023] [Accepted: 06/28/2023] [Indexed: 08/04/2023] Open
Abstract
BACKGROUND Tensiomyography measures the radial displacement of a muscle during an electrically evoked twitch contraction. Different concepts to determine the rate of displacement (Vc) from the maximum twitch exist, but information on their reproducibility is scarce. Further, different inter-stimuli intervals during progressive stimulation are used, but the effect of different intervals on Vc is unclear. OBJECTIVES The first aim of this study was to investigate the within and between-day reliability of the five most frequently used Vc concepts. The second aim was to investigate the effect of different inter-stimuli intervals on Vc. METHODS On two consecutive days, we determined Vc of the biceps femoris long head and rectus femoris of twenty-four healthy subjects. The maximum displacement was determined twice within three minutes on day one and a third time 24 h later. Also, on day two, we applied three blocks of ten consecutive stimuli at a constant intensity of 50 mA, separated by 3 min each. Inter-stimuli intervals in randomly ordered blocks were 10 s, 20 s or 30 s, respectively. RESULTS All Vc concepts displayed good to excellent relative (ICC 0.87-0.99) and generally good absolute within- and between-day reliability for both muscles. Across Vc-concepts, absolute reliability was higher for the rectus femoris (CV% 1.3-7.95%) compared to the biceps femoris (CV% 6.06-15.30%). In both muscles, Vc was generally not affected by different inter-stimuli intervals. For most Vc concepts, repeated stimulation induced an increase regardless of the inter-stimuli interval, but this effect was mainly trivial and small at most. CONCLUSIONS The reproducibility of Vc concepts was generally good but varies between different muscles. A rest interval of 10 s seems preferable to longer intervals for less time required per measurement. Following this initial study, the effect of different inter-stimuli intervals on Vc should be further investigated.
Collapse
Affiliation(s)
- Georg Langen
- Department of Sports Sciences, Goethe University Frankfurt, Frankfurt am Main, Germany
- Department of Strength, Power and Technical Sports, Institute for Applied Training Science, Leipzig, Germany
| | | | - Olaf Ueberschär
- Department of Engineering and Industrial Design, Magdeburg-Stendal University of Applied Sciences, Magdeburg, Germany
- Department of Biomechanics and Sport Technology, Institute for Applied Training Science, Leipzig, Germany
| | - Michael Behringer
- Department of Sports Sciences, Goethe University Frankfurt, Frankfurt am Main, Germany
| |
Collapse
|
10
|
McGowen JM, Hoppes CW, Forsse JS, Albin SR, Abt J, Koppenhaver SL. The Utility of Myotonometry in Musculoskeletal Rehabilitation and Human Performance Programming. J Athl Train 2023; 58:305-318. [PMID: 37418563 DOI: 10.4085/616.21] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/09/2023]
Abstract
Myotonometry is a relatively novel method used to quantify the biomechanical and viscoelastic properties (stiffness, compliance, tone, elasticity, creep, and mechanical relaxation) of palpable musculotendinous structures with portable mechanical devices called myotonometers. Myotonometers obtain these measures by recording the magnitude of radial tissue deformation that occurs in response to the amount of force that is perpendicularly applied to the tissue through a device's probe. Myotonometric parameters such as stiffness and compliance have repeatedly demonstrated strong correlations with force production and muscle activation. Paradoxically, individual muscle stiffness measures have been associated with both superior athletic performance and a higher incidence of injury. This indicates optimal stiffness levels may promote athletic performance, whereas too much or too little may lead to an increased risk of injury. Authors of numerous studies suggested that myotonometry may assist practitioners in the development of performance and rehabilitation programs that improve athletic performance, mitigate injury risk, guide therapeutic interventions, and optimize return-to-activity decision-making. Thus, the purpose of our narrative review was to summarize the potential utility of myotonometry as a clinical tool that assists musculoskeletal clinicians with the diagnosis, rehabilitation, and prevention of athletic injuries.
Collapse
Affiliation(s)
- Jared M McGowen
- Department of Health, Human Performance, and Recreation, Baylor University, Waco, TX
- US Army Medical Professional Training Brigade, San Antonio, TX
| | - Carrie W Hoppes
- Army-Baylor University Doctoral Program in Physical Therapy, San Antonio, TX
| | - Jeff S Forsse
- Department of Health, Human Performance, and Recreation, Baylor University, Waco, TX
| | | | - John Abt
- Children's Health Andrews Institute for Orthopaedics and Sports Medicine, Plano, TX
| | - Shane L Koppenhaver
- Department of Health, Human Performance, and Recreation, Baylor University, Waco, TX
- Doctoral Program in Physical Therapy, Baylor University, Waco, TX
| |
Collapse
|
11
|
Wojdała G, Krzysztofik M. The Effects of the "Sling Shot" Device on Bench Press Performance, Mechanical Properties of Muscle, and Movement Kinematics. J Strength Cond Res 2023; 37:780-786. [PMID: 36399664 DOI: 10.1519/jsc.0000000000004349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
ABSTRACT Wojdała, G and Krzysztofik, M. The effects of the "sling shot" device on bench press performance, mechanical properties of muscle, and movement kinematics. J Strength Cond Res 37(4): 780-786, 2023-This study aimed to evaluate the influence of the sling shot support device at various external loads and intensities of effort, taking into account acute changes in power performance, mechanical muscle properties, and bench press kinematics. For this purpose, 12 resistance-trained men (age: 27.1 ± 4.2 years, body mass: 90.3 ± 16.9 kg, bench press [BP] 1 repetition maximum [1RM]: 112.7 ± 23.1 kg) (resistance training experience: 6.9 ± 3.8 years) participated in the study. Each subject completed 2 experimental sessions that differed in the use of the sling shot (SS) or nonuse (CONT) of the SS and an appropriate external load. The 2 experimental sessions consisted of the 1RM test, 3 sets of 2 repetitions of BP with the load increased in each set (50-70-90% 1RM), and a fourth set of the BP efforts to muscle failure with a 70% 1RM load. Before and after each set, the changes in triceps brachii oscillation frequency and stiffness were assessed by means of myotonometry. Results indicated a significant main effect of the SS to increase peak power ( p < 0.0001, η 2 = 0.733). Furthermore, a significantly higher 1RM (129 ± 26 vs. 113 ± 23 kg, p < 0.001, effect size [ES]: 0.63), number of repetitions (15 ± 3 vs. 13 ± 2, p = 0.013, ES: 0.76), and time under tension (34 ± 10 vs. 29 ± 6 seconds, p = 0.017, ES: 0.59) were found during the set to failure for SS in comparison to the CONT condition. Moreover, there was a significant main effect of time to increase oscillation frequency ( p = 0.001; η 2 = 0.666) and stiffness ( p = 0.002; η 2 = 0.613) from pre- to postset measure. In addition, the main effect of the side ( p = 0.034; η 2 = 0.348) was reported to show higher stiffness on the dominant than on the nondominant side in the CONT condition. The results suggest that an independent 1RM measurement and a correspondingly higher workload are required to take full advantage of the SS device. Moreover, the SS can also be used successfully to increase training volume and the involvement of nondominant limbs during a bench press.
Collapse
Affiliation(s)
- Grzegorz Wojdała
- Institute of Sport Sciences, The Jerzy Kukuczka Academy of Physical Education in Katowice, Katowice, Poland
| | | |
Collapse
|
12
|
Yeom S, Jeong H, Lee H, Jeon K. Effects of Lumbar Stabilization Exercises on Isokinetic Strength and Muscle Tension in Sedentary Men. Bioengineering (Basel) 2023; 10:bioengineering10030342. [PMID: 36978733 PMCID: PMC10045455 DOI: 10.3390/bioengineering10030342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 02/25/2023] [Accepted: 03/03/2023] [Indexed: 03/11/2023] Open
Abstract
Lumbar stabilization exercises (LSE) lead to high levels of erector spinae muscle (ESM) activation, which has a positive effect on improving physical function. The purpose of this study is to identify factors explaining changes in muscle strength after 7 weeks of LSE and to evaluate changes in stiffness and contraction of the ESM. All participants (male: n = 42, age = 28.26 ± 10.97) were assessed for 60°/s isokinetic extensor muscle strength and tension using a tensiomyography (TMG) and isokinetic device before and after LSE. Maximum displacement (Dm) and average velocity up to 90% Dm (Vc 90) were significantly different before and after LSE. Additionally, participants’ 60°/s isokinetic extensor strength was significantly higher after exercise. A regression analysis was conducted to test the explanatory power of the variables, and positive results were obtained in the increase in extensor strength before and after Vc 90 and LSE. Furthermore, statistical significance was set at p < 0.05. After LSE, the increase in 60°/s isokinetic extensor strength and ESM’s Dm and Vc 90 can be interpreted as positive changes post-exercise in endurance muscles with a higher percentage of type I fibers. Our results can contribute to predicting the long-term exercise effect in sedentary workers and developing an individualized strategic exercise program.
Collapse
Affiliation(s)
- Seunghyeok Yeom
- Division of Sport Science, Incheon National University, 119 Academy-ro, Yeonsu-gu, Incheon 22012, Republic of Korea
- Functional Rehabilitation Biomechanics Laboratory, Incheon National University, 119 Academy-ro, Yeonsu-gu, Incheon 22012, Republic of Korea
| | - Hyeongdo Jeong
- Functional Rehabilitation Biomechanics Laboratory, Incheon National University, 119 Academy-ro, Yeonsu-gu, Incheon 22012, Republic of Korea
| | - Hyungwoo Lee
- Division of Sport Science, Incheon National University, 119 Academy-ro, Yeonsu-gu, Incheon 22012, Republic of Korea
- Functional Rehabilitation Biomechanics Laboratory, Incheon National University, 119 Academy-ro, Yeonsu-gu, Incheon 22012, Republic of Korea
- Department of Human Movement Science, Incheon National University, 119 Academy-ro, Yeonsu-gu, Incheon 22012, Republic of Korea
| | - Kyoungkyu Jeon
- Division of Sport Science, Incheon National University, 119 Academy-ro, Yeonsu-gu, Incheon 22012, Republic of Korea
- Functional Rehabilitation Biomechanics Laboratory, Incheon National University, 119 Academy-ro, Yeonsu-gu, Incheon 22012, Republic of Korea
- Department of Human Movement Science, Incheon National University, 119 Academy-ro, Yeonsu-gu, Incheon 22012, Republic of Korea
- Sport Science Institute, Incheon National University, 119 Academy-ro, Yeonsu-gu, Incheon 22012, Republic of Korea
- Health Promotion Center, Incheon National University, 119 Academy-ro, Yeonsu-gu, Incheon 22012, Republic of Korea
- Correspondence: ; Tel.: +82-32-835-8578
| |
Collapse
|
13
|
Assessing reliability and validity of different stiffness measurement tools on a multi-layered phantom tissue model. Sci Rep 2023; 13:815. [PMID: 36646734 PMCID: PMC9842673 DOI: 10.1038/s41598-023-27742-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Accepted: 01/06/2023] [Indexed: 01/18/2023] Open
Abstract
Changes in the mechanical properties (i.e., stiffness) of soft tissues have been linked to musculoskeletal disorders, pain conditions, and cancer biology, leading to a rising demand for diagnostic methods. Despite the general availability of different stiffness measurement tools, it is unclear as to which are best suited for different tissue types and the related measurement depths. The study aimed to compare different stiffness measurement tools' (SMT) reliability on a multi-layered phantom tissue model (MPTM). A polyurethane MPTM simulated the four layers of the thoracolumbar region: cutis (CUT), subcutaneous connective tissue (SCT), fascia profunda (FPR), and erector spinae (ERS), with varying stiffness parameters. Evaluated stiffness measurement tools included Shore Durometer, Semi-Electronic Tissue Compliance Meter (STCM), IndentoPRO, MyotonPRO, and ultrasound imaging. Measurements were made by two independent, blinded examiners. Shore Durometer, STCM, IndentoPRO, and MyotonPRO reliably detected stiffness changes in three of the four MPTM layers, but not in the thin (1 mm thick) layer simulating FPR. With ultrasound imaging, only stiffness changes in layers thicker than 3 mm could be measured reliably. Significant correlations ranging from 0.70 to 0.98 (all p < 0.01) were found. The interrater reliability ranged from good to excellent (ICC(2,2) = 0.75-0.98). The results are encouraging for researchers and clinical practitioners as the investigated stiffness measurement tools are easy-to-use and comparatively affordable.
Collapse
|
14
|
Labata-Lezaun N, Canet-Vintró M, López-de-Celis C, Rodríguez-Sanz J, Aiguadé R, Cuadra-Llopart L, Jovell-Fernández E, Bosch J, Pérez-Bellmunt A. Effectiveness of a Multicomponent Training Program on Physical Performance and Muscle Quality in Older Adults: A Quasi-Experimental Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 20:222. [PMID: 36612544 PMCID: PMC9819718 DOI: 10.3390/ijerph20010222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 12/15/2022] [Accepted: 12/20/2022] [Indexed: 06/17/2023]
Abstract
Aging is associated with a decrease in functional capacity, manifested by a loss of strength, physical performance and muscle quality. Multicomponent training (MCT), characterized by the combination of at least three types of training, could be a good strategy to counteract these changes. To date there are no studies evaluating the effectiveness of MCT in improving both physical performance and muscle quality simultaneously. The aim of this study is to evaluate the changes produced by an MCT program on both physical performance and muscle quality in a population of healthy older adults. Sixteen healthy older adults were recruited to perform a 15-session multicomponent training intervention. Physical performance was assessed by different functional tests, and muscle quality was assessed by tensiomyography and myotonometry. The main results of this study show some improvement in functional tests, but not in muscle quality parameters, except for vastus lateralis stiffness. MCT is able to generate improvements in the physical performance of older adults, but these improvements are not reflected in muscle quality parameters measured by tensiomyography and myotonometry.
Collapse
Affiliation(s)
- Noé Labata-Lezaun
- Faculty of Medicine and Health Sciences, Universitat International de Catalunya, 08195 Barcelona, Spain
- ACTIUM Functional Anatomy Group, 08195 Barcelona, Spain
| | - Max Canet-Vintró
- Faculty of Medicine and Health Sciences, Universitat International de Catalunya, 08195 Barcelona, Spain
- ACTIUM Functional Anatomy Group, 08195 Barcelona, Spain
| | - Carlos López-de-Celis
- Faculty of Medicine and Health Sciences, Universitat International de Catalunya, 08195 Barcelona, Spain
- ACTIUM Functional Anatomy Group, 08195 Barcelona, Spain
- Fundació Institut Universitari per a la Recerca a l’Atenció Primària de Salut Jordi Gol i Gurina (IDIAPJGol), 08007 Barcelona, Spain
| | - Jacobo Rodríguez-Sanz
- Faculty of Medicine and Health Sciences, Universitat International de Catalunya, 08195 Barcelona, Spain
- ACTIUM Functional Anatomy Group, 08195 Barcelona, Spain
| | - Ramón Aiguadé
- Nursing and Physiotherapy Department, Universitat de Lleida, 25198 Lleida, Spain
| | - Leonor Cuadra-Llopart
- Department of Geriatric Medicine, Consorci Sanitari de Terrassa, 08227 Terrassa, Spain
| | | | - Joan Bosch
- Faculty of Medicine and Health Sciences, Universitat International de Catalunya, 08195 Barcelona, Spain
| | - Albert Pérez-Bellmunt
- Faculty of Medicine and Health Sciences, Universitat International de Catalunya, 08195 Barcelona, Spain
- ACTIUM Functional Anatomy Group, 08195 Barcelona, Spain
| |
Collapse
|
15
|
Langen G, Sandau I, Ueberschär O, Nosaka K, Behringer M. Methodical approaches to determine the rate of radial muscle displacement using tensiomyography: A scoping review and new reporting guideline. J Electromyogr Kinesiol 2022; 67:102702. [PMID: 36183503 DOI: 10.1016/j.jelekin.2022.102702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 07/30/2022] [Accepted: 08/31/2022] [Indexed: 12/14/2022] Open
Abstract
Tensiomyography is a non-invasive method to assess skeletal muscle contractile properties from the stimulated radial displacement. Many studies have used the rate of displacement (Vc) as an indirect measure of muscle contraction velocity. However, no standardised methodical approach exists to measure displacement and determine Vc. This review aimed to provide an overview of concepts to determine Vc and measurement protocols to foster the development of a standardised methodical approach. This review followed the Preferred Reporting Items for Systematic Reviews and meta-Analyses extension for Scoping Reviews (PRISMA-ScR) guideline. Systematic searches were performed within five electronic databases and additional sources. The included 62 studies reported 10 different concepts to determine Vc, which we summarised in three groups. The determination concepts differed mainly regarding time intervals during the contraction phase considered and criteria used to define these intervals. Essential information on the equipment and raters, measurement setup, electrical stimulation procedure, and data analysis were frequently not reported. In conclusion, no consensus on how to determine Vc existed. Incomplete reporting of measurement protocols hindered study comparison, which obstructs developing a standardised approach. Therefore, we propose a new guideline for reporting measurement protocols, which covers the 1) equipment and rater, 2) measurement setup, including positioning of the subject, sensor and electrodes, 3) electrical stimulation, including initial stimulation amplitude, increment, and endpoint, and 4) data analysis, including selection criteria and number of analysed signals and a definition of derived parameters.
Collapse
Affiliation(s)
- G Langen
- Department of Sports Medicine and Performance Physiology, Goethe University Frankfurt, Frankfurt, Germany; Department of Strength Power and Technical Sports, Institute for Applied Training Science, Leipzig, Germany.
| | - I Sandau
- Department of Strength Power and Technical Sports, Institute for Applied Training Science, Leipzig, Germany
| | - O Ueberschär
- Department of Engineering and Industrial Design, Magdeburg-Stendal University of Applied Sciences, Magdeburg, Germany; Department of Biomechanics, Institute for Applied Training Science, Leipzig, Germany
| | - K Nosaka
- Centre for Human Performance, School of Medical and Health Sciences, Edith Cowan University, Joondalup, WA, Australia
| | - M Behringer
- Department of Sports Medicine and Performance Physiology, Goethe University Frankfurt, Frankfurt, Germany
| |
Collapse
|
16
|
Buoite Stella A, Galimi A, Martini M, Di Lenarda L, Murena L, Deodato M. Muscle Asymmetries in the Lower Limbs of Male Soccer Players: Preliminary Findings on the Association between Countermovement Jump and Tensiomyography. Sports (Basel) 2022; 10:177. [PMID: 36422945 PMCID: PMC9694285 DOI: 10.3390/sports10110177] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Revised: 11/08/2022] [Accepted: 11/11/2022] [Indexed: 09/01/2023] Open
Abstract
Strength and power asymmetries have been observed in different sports, including soccer. Such asymmetries, as well as the bilateral deficit (BLD), can be assessed during different tasks, static or dynamic, and with different methods and devices, in order to detect the possible different aspects, as well as the association with physical performance and injuries. The aim of this study was to investigate the association between muscle asymmetries and BLD during a countermovement jump (CMJ), and tensiomyography (TMG) parameters and asymmetries, in the lower limbs of male soccer players. A total of 23 male soccer players (18 ± 4 years) were recruited. Bilateral and unilateral CMJs were performed, and peak power (W) and height (cm) were obtained. TMG was performed on different muscles of the lower limbs, and lateral and functional symmetries were obtained. Playing position and history of injuries were collected. CMJ inter-limb symmetry was found to significantly correlate with biceps femoris (r = 0.574, p = 0.004) and soleus (r = 0.437, p = 0.037) lateral symmetry. Players in central roles presented significantly worse functional symmetry scores of the knee than defense players (-17.5%, 95% CI -31.2--3.9; p = 0.10). Participants reporting a history of injury at the ankle were characterized by significantly lower functional symmetry in both the dominant (43%, 39.5-48.0 vs. 74.5%, 46.5-89.3, p = 0.019) and non-dominant (45%, 42.5-46.0 vs. 81.0%, 45.8-90.3, p = 0.024) ankle. Findings from this preliminary study suggest an association between lower-limb muscle asymmetries during a dynamic task, such as jumping, and muscle contractile properties evaluated with TMG; moreover, functional asymmetries may be present after ankle injuries. Future studies in larger samples should evaluate the presence of such asymmetries as predictors or characteristics of different muscular and joint injuries.
Collapse
Affiliation(s)
- Alex Buoite Stella
- School of Physiotherapy, Department of Medicine, Surgery and Health Sciences, University of Trieste, Via Pascoli 31, 34100 Trieste, Italy
- Clinical, Integrative and Translational Physiology, Department of Medicine, Surgery and Health Sciences, University of Trieste, Strada di Fiume 447, 34149 Trieste, Italy
| | - Annalisa Galimi
- School of Physiotherapy, Department of Medicine, Surgery and Health Sciences, University of Trieste, Via Pascoli 31, 34100 Trieste, Italy
| | - Miriam Martini
- School of Physiotherapy, Department of Medicine, Surgery and Health Sciences, University of Trieste, Via Pascoli 31, 34100 Trieste, Italy
| | - Luca Di Lenarda
- Orthopaedics and Traumatology Unit, Cattinara Hospital-ASUGI, Department of Medicine, Surgery and Health Sciences, University of Trieste, Strada di Fiume 447, 34149 Trieste, Italy
| | - Luigi Murena
- School of Physiotherapy, Department of Medicine, Surgery and Health Sciences, University of Trieste, Via Pascoli 31, 34100 Trieste, Italy
- Orthopaedics and Traumatology Unit, Cattinara Hospital-ASUGI, Department of Medicine, Surgery and Health Sciences, University of Trieste, Strada di Fiume 447, 34149 Trieste, Italy
| | - Manuela Deodato
- School of Physiotherapy, Department of Medicine, Surgery and Health Sciences, University of Trieste, Via Pascoli 31, 34100 Trieste, Italy
- Ph.D. Program in Neural and Cognitive Sciences, Department of Life Sciences, University of Trieste, Via Weiss 2, 34100 Trieste, Italy
| |
Collapse
|
17
|
Li Y, Yu J, Zhang J, Zhang Z, Wang X. Quantifying the stiffness of lumbar erector spinae during different positions among participants with chronic low back pain. PLoS One 2022; 17:e0270286. [PMID: 35749429 PMCID: PMC9231815 DOI: 10.1371/journal.pone.0270286] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Accepted: 06/07/2022] [Indexed: 11/19/2022] Open
Abstract
Objective The purposes of this study were to (1) detect the intra- and inter-reliabilities of the lumbar erector spinae stiffness by MyotonPRO among participants with chronic lower back pain (CLBP); (2) compare the muscle stiffness between pain and non-pain sides during different positions; (3) explore the correlation between intensity of pain and muscle stiffness. Design Twenty participants with CLBP were recruited and the stiffness measurements were carried out by two experienced physiotherapists (operators Ⅰ and Ⅱ). Each participant was evaluated by the operatorⅠ in different postures (static prone and sitting). After a 5-day interval, the same participant was reassessed by the operatorⅠ in the static prone posture. For the inter-rater reliability test, each participant was quantified by both operators once, with 30 minutes between the measurements on the same day. The intensity of pain was evaluated using a 0–10 visual analog scale (VAS). Results The intra- and inter-rater reliabilities were excellent (ICC = 0.88–0.99). The MDC values ranged from 25.03 to 86.26 N/m. Examples of Bland-Altman plots showed good agreement. The erector spinae stiffness on the painful sides was higher with a marked increase in the sitting position (P < .05) when compared with the non-painful side. However, there was no significant difference in the prone position (P > .05). The intensity of pain among adults with CLBP was not associated with muscle stiffness of the lumbar erector spinae muscle. Conclusions Our findings indicated that the MyotonPRO is a feasible device in quantifying the stiffness of the lumbar erector spinae muscle in patients with CLBP. Meanwhile, the erector spinae stiffness on the painful sides was higher in the sitting when compared with the non-painful side.
Collapse
Affiliation(s)
- Yapeng Li
- Rehabilitation Therapy Center, Luoyang Orthopedic Hospital of Henan Province, Orthopedic Hospital of Henan Province, Luoyang, China
| | - Jiafeng Yu
- Department of Rehabilitation Medicine, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Jun Zhang
- Department of Rehabilitation, Institute of Rehabilitation and Health Care, Hunan Traditional Chinese Medical College, Hunan, China
| | - Zhijie Zhang
- Rehabilitation Therapy Center, Luoyang Orthopedic Hospital of Henan Province, Orthopedic Hospital of Henan Province, Luoyang, China
- * E-mail:
| | - Xueqiang Wang
- Department of Sport Rehabilitation, Shanghai University of Sport, Shanghai, China
| |
Collapse
|
18
|
Khiyami A, Nuhmani S, Joseph R, Abualait TS, Muaidi Q. Efficacy of Core Training in Swimming Performance and Neuromuscular Parameters of Young Swimmers: A Randomised Control Trial. J Clin Med 2022; 11:jcm11113198. [PMID: 35683586 PMCID: PMC9181058 DOI: 10.3390/jcm11113198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 05/25/2022] [Accepted: 06/02/2022] [Indexed: 11/16/2022] Open
Abstract
Background: This study aimed to investigate the efficacy of core training in the swimming performance and neuromuscular properties of young swimmers. Methods: Eighteen healthy male swimmers (age: 13 ± 2 years, height: 159.6 ± 14.5 cm, weight: 48.7 ± 12.4 kg) were recruited from the Public Authority for Sports swimming pool in Dammam and randomly assigned to the experimental and control groups. The experimental group performed a six-week core-training program consisting of seven exercises (three times/week) with regular swimming training. The control group maintained its regular training. Swimming performance and neuromuscular parameters were measured pre- and post-interventions. Results: The experimental group benefitted from the intervention in terms of the 50 m swim time (−1.4 s; 95% confidence interval −2.4 to −0.5) compared with the control group. The experimental group also showed improved swimming velocity (+0.1 m.s−1), stroke rate (−2.8 cycle.min−1), stroke length (+0.2 m.cycle−1), stroke index (+0.4 m2·s−1), total strokes (−2.9 strokes), and contraction time for erector spinae (ES; −1.5 ms), latissimus dorsi (LD; −7 ms), and external obliques (EO; −1.9 ms). Maximal displacement ES (DM-ES) (+3.3 mm), LD (0.5 mm), and EO (+2.2 mm) were compared with the baseline values for the experimental group, and TC-ES (5.8 ms), LD (3.7 ms), EO (2.5 ms), DM-ES (0.2 mm), LD (−4.1 mm), and EO (−1.0 mm) were compared with the baseline values for the control group. The intergroup comparison was statistically significant (p < 0.05; DM-ES p > 0.05). Conclusion: The results indicate that a six-week core-training program with regular swimming training improved the neuromuscular properties and the 50 m freestyle swim performance of the experimental group compared with the control group.
Collapse
Affiliation(s)
- Ahmad Khiyami
- Department of Physical Therapy, College of Applied Medical Sciences, Imam Abdulrahman Bin Faisal University, Dammam 31451, Saudi Arabia; (A.K.); (T.S.A.); (Q.M.)
| | - Shibili Nuhmani
- Department of Physical Therapy, College of Applied Medical Sciences, Imam Abdulrahman Bin Faisal University, Dammam 31451, Saudi Arabia; (A.K.); (T.S.A.); (Q.M.)
- Correspondence: ; Tel.: +966-554270531
| | - Royes Joseph
- Department of Pharmacy Practice, College of Clinical Pharmacy, Imam Abdulrahman Bin Faisal University, Dammam 31451, Saudi Arabia;
| | - Turki Saeed Abualait
- Department of Physical Therapy, College of Applied Medical Sciences, Imam Abdulrahman Bin Faisal University, Dammam 31451, Saudi Arabia; (A.K.); (T.S.A.); (Q.M.)
| | - Qassim Muaidi
- Department of Physical Therapy, College of Applied Medical Sciences, Imam Abdulrahman Bin Faisal University, Dammam 31451, Saudi Arabia; (A.K.); (T.S.A.); (Q.M.)
| |
Collapse
|
19
|
Iglesias-Caamaño M, Álvarez-Yates T, Carballo-López J, Cuba-Dorado A, García-García O. Interday Reliability of a Testing Battery to Assess Lateral Symmetry and Performance in Well-Trained Volleyball Players. J Strength Cond Res 2022; 36:895-901. [PMID: 35318998 DOI: 10.1519/jsc.0000000000003630] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
ABSTRACT Iglesias-Caamaño, M, Álvarez-Yates, T, Carballo-López, J, Cuba-Dorado, A, and García-García, O. Interday reliability of a testing battery to assess lateral symmetry and performance in well-trained volleyball players. J Strength Cond Res 36(4): 895-901, 2022-This study aimed to determine the relative and absolute interday reliability of a testing battery for lateral asymmetry detection and performance in well-trained volleyball players and to determine whether retaining for analysis the best or the average value of 3 attempts would modulate the interday reliability and the magnitude of asymmetry. Thirteen Superleague-2 male volleyball players performed on 3 different days a 5-test battery composed of 4 tests for assessing muscle asymmetries: active knee extension, Y-balance test (YBT), modified 20-yard shuttle run (M-20Y), and single-leg countermovement jump; and one for volleyball sports performance: attack jump (AJ). The intraclass correlation index and coefficient of variation (CV) together with the standard error of measurement (SEM, %SEM) and the minimum detectable change (MDC, %MDC) were taken to calculate relative and absolute reliability. Two-way repeated-measures analysis of variance was used to establish the differences between the best value and the average value in each session. The low %MDC (<10%) suggests that all the tests that make up the testing battery would have good sensitivity to detect possible asymmetries. All tests have shown an excellent interday absolute reliability (CV <4.5%; %SEM < 5%), both when retaining the best value and the average value of the 3 attempts. In addition, AJ and YBT (on both legs) obtained a good-excellent relative reliability, whereas the M-20Y test seems to show a lower relative reliability. Retaining the best value or the average value to determine the magnitude and direction of asymmetry seems to be equally reliable with no differences between both values.
Collapse
Affiliation(s)
- Mario Iglesias-Caamaño
- Laboratory of Sports Performance, Physical Condition and Wellness, Faculty of Education and Sport Sciences, University of Vigo, Pontevedra, Spain
| | | | | | | | | |
Collapse
|
20
|
Acute Effects of Different Intensities during Bench Press Exercise on the Mechanical Properties of Triceps Brachii Long Head. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12063197] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
This study aimed to analyze acute changes in the muscle mechanical properties of the triceps brachii long head after bench press exercise performed at different external loads and with different intensities of effort along with power performance. Ten resistance-trained males (age: 27.7 ± 3.7 yr, body mass: 90.1 ± 17.1 kg, height: 184 ± 4 cm; experience in resistance training: 5.8 ± 2.6 yr, relative one-repetition maximum (1RM) in the bench press: 1.23 ± 0.22 kg/body mass) performed two different testing conditions in a randomized order. During the experimental session, participants performed four successive sets of two repetitions of the bench press exercise at: 50, 70, and 90% 1RM, respectively, followed by a set at 70% 1RM performed until failure, with a 4 min rest interval between each set. Immediately before and after each set, muscle mechanical properties of the dominant limb triceps brachii long head were assessed via a Myoton device. To determine fatigue, peak and average barbell velocity were measured at 70% 1RM and at 70% 1RM until failure (only first and second repetition). In the control condition, only muscle mechanical properties at the same time points after the warm-up were assessed. The intraclass correlation coefficients indicated “poor” to “excellent” reliability for decrement, relaxation time, and creep. Therefore, these variables were excluded from further analysis. Three-way ANOVAs (2 groups × 2 times × 4 loads) indicated a statistically significant group × time interaction for muscle tone (p = 0.008). Post hoc tests revealed a statistically significant increase in muscle tone after 70% 1RM (p = 0.034; ES = 0.32) and 90% 1RM (p = 0.011; ES = 0.56). No significant changes were found for stiffness. The t-tests indicated a significant decrease in peak (p = 0.001; ES = 1.02) and average barbell velocity (p = 0.008; ES = 0.8) during the first two repetitions of a set at 70% 1RM until failure in comparison to the set at 70% 1RM. The results indicate that low-volume, high-load resistance exercise immediately increases muscle tone but not stiffness. Despite no significant changes in the mechanical properties of the muscle being registered simultaneously with a decrease in barbell velocity, there was a trend of increased muscle tone. Therefore, further studies with larger samples are required to verify whether muscle tone could be a sensitive marker to detect acute muscle fatigue.
Collapse
|
21
|
Effects of Core Stabilization Exercise Programs on Changes in Erector Spinae Contractile Properties and Isokinetic Muscle Function of Adult Females with a Sedentary Lifestyle. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12052501] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
This study aimed to investigate the effect of core stabilization exercises on the contractile properties and isokinetic muscle function of adult females with a sedentary lifestyle. We enrolled 105 adult females. Tensiomyography was performed on the erector spinae, and the isokinetic muscular functional test was performed on the trunk at an angular velocity of 60°/s and 90°/s. All participants performed the exercise for 60 min per day, 3 times a week, for 7 weeks. A Wilcoxon signed-rank test was performed at a significance level of 0.05. Tensiomyography (TMG) of the erector spinae revealed no significant post-exercise change in the contraction time; however, there was a significant post-exercise increase in the maximum radial displacement and mean velocity until 90% of the TMG was displaced. Additionally, the isokinetic muscular functional test of the trunk revealed a significant post-exercise increase in almost all variables. Our findings demonstrated that the core stabilization exercise reduced stiffness in the erector spinae, increased the velocity of erector spinae contraction, and effectively improved the isokinetic muscular function of the trunk.
Collapse
|
22
|
Nguyen AP, Detrembleur C, Fisette P, Selves C, Mahaudens P. MyotonPro Is a Valid Device for Assessing Wrist Biomechanical Stiffness in Healthy Young Adults. Front Sports Act Living 2022; 4:797975. [PMID: 35265831 PMCID: PMC8899712 DOI: 10.3389/fspor.2022.797975] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Accepted: 01/26/2022] [Indexed: 12/03/2022] Open
Abstract
Background The MyotonPro is a portable device for measuring biomechanical and viscoelastic properties in superficial soft tissues. The aims of this study are firstly to validate the MyotonPro compared to a reliable gold-standard frame and secondly to observe the influence of MyotonPro measurement on the total wrist viscoelasticity. Methods Three silicone polymers with different elastic properties were assessed with the MyotonPro and with a reference rheometer (Universal Tribometer Mod). Then, a free oscillations method was used to measure the passive elastic and viscous stiffness of the wrist and compared to MyotonPro forearm measurements. Results A one-way ANOVA demonstrated the validity of the MyotonPro's stiffness (p = 0.001), decrement (p < 0.001), and relaxation (p = 0.008) parameters for measuring the elastic stiffness (k) of the three polymers. The MyotonPro parameters demonstrated excellent reliability on the forearm. Proximal and distal anterior myofascial measurements of the MyotonPro were moderately correlated to the elastic stiffness (p = 0.0027-0.0275, absolute r = from 0.270 to 0.375) of the wrist while the postero-distal myofascial tissues of the forearm demonstrated a moderate correlation with the viscous stiffness of the wrist (p = 0.0096-0.0433, absolute r = from 0.257 to 0.326). Discussion The MyotonPro is a valid device for measuring elastic stiffness as well as a portable, affordable, and easy-to-use tool for quantifying the biomechanical properties and viscoelasticity of myofascial tissue in healthy subjects.
Collapse
Affiliation(s)
- Anh Phong Nguyen
- Neuromusculoskeletal Laboratory, Institut de Recherche Expérimentale et Clinique, Catholic University of Louvain, Louvain-la-Neuve, Belgium
| | - Christine Detrembleur
- Neuromusculoskeletal Laboratory, Institut de Recherche Expérimentale et Clinique, Catholic University of Louvain, Louvain-la-Neuve, Belgium
| | - Paul Fisette
- Institute of Mechanics, Materials and Civil Engineering, Mechatronic, Electrical Energy and Dynamic Systems, Catholic University of Louvain, Louvain-la-Neuve, Belgium
| | - Clara Selves
- Neuromusculoskeletal Laboratory, Institut de Recherche Expérimentale et Clinique, Catholic University of Louvain, Louvain-la-Neuve, Belgium
- Service de Médecine Physique et Réadaptation, Cliniques Universitaires Saint-Luc, Woluwe-Saint-Lambert, Belgium
| | - Philippe Mahaudens
- Neuromusculoskeletal Laboratory, Institut de Recherche Expérimentale et Clinique, Catholic University of Louvain, Louvain-la-Neuve, Belgium
- Service de Médecine Physique et Réadaptation, Cliniques Universitaires Saint-Luc, Woluwe-Saint-Lambert, Belgium
| |
Collapse
|
23
|
Myotonometric Evaluation of Latent Myofascial Trigger Points and Taut Band in Elite Athletes. JOURNAL OF BASIC AND CLINICAL HEALTH SCIENCES 2022. [DOI: 10.30621/jbachs.959275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
24
|
Wu Z, Ye X, Ye Z, Hong K, Chen Z, Wang Y, Li C, Li J, Huang J, Zhu Y, Lu Y, Liu W, Xu X. Asymmetric Biomechanical Properties of the Paravertebral Muscle in Elderly Patients With Unilateral Chronic Low Back Pain: A Preliminary Study. Front Bioeng Biotechnol 2022; 10:814099. [PMID: 35223786 PMCID: PMC8866935 DOI: 10.3389/fbioe.2022.814099] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 01/17/2022] [Indexed: 11/13/2022] Open
Abstract
Background: Clinical incidences of chronic low back pain among the elderly are increasing. However, studies have not fully elucidated on changes in biomechanical properties of paravertebral muscles in patients with unilateral chronic low back pain. We evaluated the changes in biomechanical properties of painful and non-painful paravertebral muscles in elderly patients with unilateral chronic low back pain.Methods: Biomechanical properties of paravertebral muscles, including muscle tone and stiffness, in elderly patients with unilateral chronic low back pain were measured using MyotonPRO. Lumbar Lordosis and Sacral Slope were measured by magnetic resonance imaging. Cross-sectional areas of paravertebral muscles were evaluated using ImageJ software version 1.53. Chronic low back pain severity was assessed by Visual Analogue Scale (VAS) and Oswestry Disability Index (ODI) scores. The correlations between VAS scores, ODI scores, Lumbar Lordosis, Sacral Slope, cross-sectional areas (painful side), disease duration, and biomechanical properties of paravertebral muscles in the painful side were analyzed.Results: A total of 60 elderly patients with unilateral chronic low back pain were enrolled in this study. The muscle tone and stiffness of paravertebral muscles on the painful side were significantly higher than those on the non-painful side (p < .05). Cross-sectional areas of paravertebral muscles on the painful side at the L3 level were smaller than those of the non-painful side (p < .05). The VAS scores and ODI scores were significantly positively correlated with muscle tone and stiffness of paravertebral muscles on the painful side (p < .05 and p < .01, respectively). There were no significant correlations between disease duration, cross-sectional areas (painful side), Lumbar Lordosis, or Sacral Slope and muscle tone and stiffness of paravertebral muscles on the painful side (p > .05).Conclusion: In elderly patients with unilateral chronic low back pain, muscle tone and stiffness of paravertebral muscles on the painful side are higher than for those on the non-painful side. The asymmetry of biomechanical properties of paravertebral muscles is associated with severity of chronic low back pain.
Collapse
Affiliation(s)
- Zugui Wu
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Xiangling Ye
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Zixuan Ye
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Kunhao Hong
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
- Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, China
| | - Zehua Chen
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Yi Wang
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Congcong Li
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Junyi Li
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Jinyou Huang
- Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, China
| | - Yue Zhu
- Baishui Health Center, Qujing, China
| | - Yanyan Lu
- Luoyang Orthopedic Hospital Of Henan Province (Orthopedic Hospital of Henan Province), Zhengzhou, China
- *Correspondence: Xuemeng Xu, ; Wengang Liu, ; Yanyan Lu,
| | - Wengang Liu
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
- Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, China
- *Correspondence: Xuemeng Xu, ; Wengang Liu, ; Yanyan Lu,
| | - Xuemeng Xu
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
- Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, China
- *Correspondence: Xuemeng Xu, ; Wengang Liu, ; Yanyan Lu,
| |
Collapse
|
25
|
Alcaraz-Clariana S, García-Luque L, Garrido-Castro JL, Carmona-Pérez C, Rodrigues-de-Souza DP, Fernández-de-las-Peñas C, Alburquerque-Sendín F. Influence of Spinal Movements Associated with Physical Evaluation on Muscle Mechanical Properties of the Lumbar Paraspinal in Subjects with Acute Low Back Pain. Diagnostics (Basel) 2022; 12:diagnostics12020302. [PMID: 35204392 PMCID: PMC8870934 DOI: 10.3390/diagnostics12020302] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 01/11/2022] [Accepted: 01/24/2022] [Indexed: 12/29/2022] Open
Abstract
This research aimed to identify changes in muscle mechanical properties (MMPs) when a standardized sequence of movements is performed and to determine the influence of acute low back pain (LBP) and age on the MMPs. Socio-demographic, clinical variables and MMPs were collected in 33 patients with LBP and 33 healthy controls. A 2 × 2 × 2 (group × age × time) analysis of variance (ANOVA) mixed model was used to determine the effect of the study factors on the different MMPs. There were no significant triple interactions. After the movements, tone and stiffness increased 0.37 Hz and 22.75 N/m, respectively, in subjects <35 years, independent of their clinical status. Relaxation showed differences by age in healthy subjects and creep in LBP subjects. Furthermore, elasticity was higher in <35 years (p < 0.001) without the influence of any other factor. In conclusion, sequenced movements can modify tone and stiffness as a function of age, while age-associated changes in viscoelastic characteristics depends on pain but not on movements. The MMPs should be assessed, not only at the beginning of the physical examination at rest, but also along the patient’s follow-up, depending on their pain and age, in a clinical setting.
Collapse
Affiliation(s)
- Sandra Alcaraz-Clariana
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004 Córdoba, Spain; (S.A.-C.); (L.G.-L.); (C.C.-P.); (D.P.R.-d.-S.); (F.A.-S.)
| | - Lourdes García-Luque
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004 Córdoba, Spain; (S.A.-C.); (L.G.-L.); (C.C.-P.); (D.P.R.-d.-S.); (F.A.-S.)
| | - Juan Luis Garrido-Castro
- Department of Computer Science and Numerical Analysis, Rabanales Campus, University of Córdoba, 14071 Córdoba, Spain;
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004 Córdoba, Spain
| | - Cristina Carmona-Pérez
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004 Córdoba, Spain; (S.A.-C.); (L.G.-L.); (C.C.-P.); (D.P.R.-d.-S.); (F.A.-S.)
| | - Daiana Priscila Rodrigues-de-Souza
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004 Córdoba, Spain; (S.A.-C.); (L.G.-L.); (C.C.-P.); (D.P.R.-d.-S.); (F.A.-S.)
| | - César Fernández-de-las-Peñas
- Department of Physical Therapy, Occupational Therapy, Rehabilitation and Physical Medicine, Universidad Rey Juan Carlos, Alcorcón, 28922 Madrid, Spain
- Cátedra Institucional en Docencia, Clínica e Investigación en Fisioterapia: Terapia Manual, Punción Seca y Ejercicio Terapéutico, Universidad Rey Juan Carlos, Alcorcón, 28922 Madrid, Spain
- Correspondence: ; Tel.: +34-914-888-884; Fax: +34-914-888-957
| | - Francisco Alburquerque-Sendín
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004 Córdoba, Spain; (S.A.-C.); (L.G.-L.); (C.C.-P.); (D.P.R.-d.-S.); (F.A.-S.)
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004 Córdoba, Spain
| |
Collapse
|
26
|
Langen G, Lohr C, Ueberschär O, Behringer M. Reproducibility of knee extensor and flexor contraction velocity in healthy men and women assessed using tensiomyography: A study protocol. PLoS One 2022; 17:e0262156. [PMID: 34990494 PMCID: PMC8735606 DOI: 10.1371/journal.pone.0262156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Accepted: 12/17/2021] [Indexed: 11/19/2022] Open
Abstract
Tensiomyography measures the radial displacement of a muscle during an electrically evoked twitch contraction. The rate of muscle displacement is increasingly reported to assess contractile properties. Several formulas currently exist to calculate the rate of displacement during the contraction phase of the maximal twitch response. However, information on the reproducibility of these formulas is scarce. Further, different rest intervals ranging from 10 s to 30 s are applied between consecutive stimuli during progressive electrical stimulation until the maximum twitch response. The effect of different rest intervals on the rate of displacement has not been investigated so far. The first aim of this study is to investigate the within and between-day reliability of the most frequently used formulas to calculate the rate of displacement. The second aim is to investigate the effect of changing the inter-stimulus interval on the rate of displacement. We will determine the rectus femoris and biceps femoris rate of displacement of twenty-four healthy subjects’ dominant leg on two consecutive days. The maximum displacement curve will be determined two times within three minutes on the first day and a third time 24 h later. On day two, we will also apply three blocks of ten consecutive stimuli at a constant intensity of 50 mA. Inter-stimuli intervals will be 10 s, 20 s or 30 s in each block, respectively, and three minutes between blocks. The order of inter-stimulus intervals will be randomized. This study will allow a direct comparison between the five most frequently used formulas to calculate the rate of displacement in terms of their reproducibility. Our data will also inform on the effect of different inter-stimulus intervals on the rate of displacement. These results will provide helpful information on methodical considerations to determine the rate of displacement and may thus contribute to a standardized approach.
Collapse
Affiliation(s)
- Georg Langen
- Department of Sports Medicine and Performance Physiology, Goethe University Frankfurt, Frankfurt, Germany
- Department of Technical-Tactical Sports, Institute for Applied Training Science, Leipzig, Germany
- * E-mail:
| | | | - Olaf Ueberschär
- Department of Engineering and Industrial Design, Magdeburg-Stendal University of Applied Sciences, Magdeburg, Germany
- Department of Biomechanics, Institute for Applied Training Science, Leipzig, Germany
| | - Michael Behringer
- Department of Sports Medicine and Performance Physiology, Goethe University Frankfurt, Frankfurt, Germany
| |
Collapse
|
27
|
Effects of Kinesio Taping on Muscle Contractile Properties: Assessment Using Tensiomyography. J Sport Rehabil 2021; 31:263-270. [PMID: 34731832 DOI: 10.1123/jsr.2020-0495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 06/25/2021] [Accepted: 08/31/2021] [Indexed: 11/18/2022]
Abstract
CONTEXT Although functional effects of kinesio taping (KT) have been widely studied, its effects on contractile properties of the target muscle remain unclear. Tensiomyography is suitable for quantifying muscle stiffness and rate of force development upon imposed twitch contraction. OBJECTIVE To test the hypothesis that KT has effects on contractile properties of targeted muscle using tensiomyography. DESIGN Prospective cohort study. SETTINGS Performance laboratory of a sports rehabilitation center. PARTICIPANTS A total of 11 healthy volunteers. INTERVENTIONS Tensiomyography measurements before KT facilitation technique applied (pre-KT), 45 minutes, and 24 hours after KT (post-KT1 and post-KT2, respectively) without removing the tape. MAIN OUTCOME MEASURES Maximal radial displacement, contraction time, delay time, sustain time, relaxation time, and velocity of contraction. RESULTS Significant effects were shown for maximal radial displacement (P = .004), contraction time (P = .013), relaxation time (P = .035), and velocity of contraction (P = .0033), but not for delay time (P = .060) and sustain time (P = .078). Post hoc testing indicated a significant decrease in maximal radial displacement for post-KT1 only (from 6.33 [1.46] to 4.87 [2.14] mm), and a significant increase in contraction time for both post-KT1 and post-KT2 (from 30.87 [11.39] to 39.71 [13.49] ms, and 37.41 [14.73] ms, respectively). Post hoc testing also showed a significant decrease in relaxation time for post-KT2 (from 65.97 [53.43] to 47.45 [38.12] ms), and a significant decrease in velocity of contraction for both post-KT1 and post-KT2 (from 0.22 [0.08] to 0.15 [0.09] mm/s, and 0.16 [0.07] mm/s), respectively. CONCLUSION The findings indicate that KT leads to an increased muscle stiffness and a reduced muscle rate of force production despite the facilitation technique applied.
Collapse
|
28
|
Alcaraz-Clariana S, García-Luque L, Garrido-Castro JL, Aranda-Valera IC, Ladehesa-Pineda L, Puche-Larrubia MÁ, Carmona-Pérez C, Rodrigues-de-Souza DP, Alburquerque-Sendín F. Paravertebral Muscle Mechanical Properties in Patients with Axial Spondyloarthritis or Low Back Pain: A Case-Control Study. Diagnostics (Basel) 2021; 11:1898. [PMID: 34679595 PMCID: PMC8535094 DOI: 10.3390/diagnostics11101898] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 10/06/2021] [Accepted: 10/12/2021] [Indexed: 12/29/2022] Open
Abstract
Different musculoskeletal disorders are a source of pain in the spinal region; most of them can be divided into mechanical, such as low back pain (LBP), or inflammatory origins, as is the case of axial spondyloarthritis (axSpA). Nevertheless, insufficient information is available about the muscle negative consequences of these conditions. Thus, the objective of this study was to identify whether mechanical muscle properties (MMPs) of cervical and lumbar muscles are different between patients with axSpA, subacute LBP (sLBP), and healthy controls. Furthermore, we aimed identify whether MMPs were related to sociodemographic and clinical variables in various study groups. The MMPs, sociodemographic, and clinical variables were obtained in 43 patients with axSpA, 43 subjects with sLBP, and 43 healthy controls. One-way ANOVAs and ROC curves were applied to identify whether the MMPs could differentiate between the study groups. Intra-group Pearson r coefficients to test the associations between MMPs and the rest of the variables were calculated. The results showed that axSpA subjects have a higher tone and stiffness and a lower relaxation and creep than sLBP and healthy ones (p < 0.05). All lumbar and cervical MMPs, except for decrement, could correctly classify axSpA and healthy subjects and axSpA and sLBP patients (in both cases, Area Under the Curve > 0.8). However, no MMP could differentiate between sLBP and healthy subjects. Each group had a different pattern of bivariate correlations between MMPs and sociodemographic and clinical data, with a worse state and progression of the axSpA group associated with a higher tone and stiffness in both spinal regions. This study supports that MMPs are different and show different patterns of correlations depending on the type of spinal pain.
Collapse
Affiliation(s)
- Sandra Alcaraz-Clariana
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Cordoba, 14004 Cordoba, Spain; (S.A.-C.); (L.G.-L.); (C.C.-P.); (F.A.-S.)
| | - Lourdes García-Luque
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Cordoba, 14004 Cordoba, Spain; (S.A.-C.); (L.G.-L.); (C.C.-P.); (F.A.-S.)
| | - Juan Luis Garrido-Castro
- Department of Computer Science and Numerical Analysis, Rabanales Campus, University of Cordoba, 14071 Cordoba, Spain;
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004 Cordoba, Spain; (I.C.A.-V.); (L.L.-P.); (M.Á.P.-L.)
| | - I. Concepción Aranda-Valera
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004 Cordoba, Spain; (I.C.A.-V.); (L.L.-P.); (M.Á.P.-L.)
- Department of Rheumatology, University Hospital Reina Sofía, 14004 Cordoba, Spain
- Department of Medical and Surgical Sciences, University of Cordoba, 14004 Cordoba, Spain
| | - Lourdes Ladehesa-Pineda
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004 Cordoba, Spain; (I.C.A.-V.); (L.L.-P.); (M.Á.P.-L.)
- Department of Rheumatology, University Hospital Reina Sofía, 14004 Cordoba, Spain
- Department of Medical and Surgical Sciences, University of Cordoba, 14004 Cordoba, Spain
| | - María Ángeles Puche-Larrubia
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004 Cordoba, Spain; (I.C.A.-V.); (L.L.-P.); (M.Á.P.-L.)
- Department of Rheumatology, University Hospital Reina Sofía, 14004 Cordoba, Spain
- Department of Medical and Surgical Sciences, University of Cordoba, 14004 Cordoba, Spain
| | - Cristina Carmona-Pérez
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Cordoba, 14004 Cordoba, Spain; (S.A.-C.); (L.G.-L.); (C.C.-P.); (F.A.-S.)
| | - Daiana Priscila Rodrigues-de-Souza
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Cordoba, 14004 Cordoba, Spain; (S.A.-C.); (L.G.-L.); (C.C.-P.); (F.A.-S.)
| | - Francisco Alburquerque-Sendín
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Cordoba, 14004 Cordoba, Spain; (S.A.-C.); (L.G.-L.); (C.C.-P.); (F.A.-S.)
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004 Cordoba, Spain; (I.C.A.-V.); (L.L.-P.); (M.Á.P.-L.)
| |
Collapse
|
29
|
Garrido-Castro JL, Aranda-Valera IC, Peña-Amaro J, Martínez-Galisteo A, González-Navas C, Rodrigues-de-Souza DP, Alcaraz-Clariana S, García-Luque L, Sánchez IRM, López-Medina C, Collantes-Estévez E, Alburquerque-Sendín F. Mechanical Properties of Lumbar and Cervical Paravertebral Muscles in Patients with Axial Spondyloarthritis: A Case-Control Study. Diagnostics (Basel) 2021; 11:diagnostics11091662. [PMID: 34574003 PMCID: PMC8472659 DOI: 10.3390/diagnostics11091662] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Revised: 08/31/2021] [Accepted: 09/08/2021] [Indexed: 02/06/2023] Open
Abstract
Background: Axial spondyloarthritis (axSpA) affects spinal muscles, due to inflammation and structural damage. The mechanical properties of the muscles, such as tone or stiffness, could be altered in axSpA. The aim of this work is to analyze the mechanical properties of cervical and lumbar spine muscles in axSpA patients and their relationship with metrology measures, function, disease activity, structural damage and quality of life. Methods: axSpA patients and age/gender/BMI matched healthy controls were recruited. The muscle mechanical properties (MMPs), such as tone or frequency, stiffness, decrement (linear elastic properties), relaxation and creep (viscoelastic properties), of cervical (semispinalis capitis) and lumbar (erector spinae) muscles were bilaterally measured at rest using myotonometry. Additionally, conventional metrology, BASMI (metrology index), BASDAI (disease activity index), mSASSS (radiological structural damage index) and SF-12 (health-related quality of life questionnaire) were used in the axSpA group. Between-groups comparison, intra-group correlations and multivariable regression analyses were performed to achieve the study aims. Results: Thirty-four axSpA patients (mean age: 46.21 ± 8.53 y) and 34 healthy volunteers (mean age: 43.97 ± 8.49 y) were recruited. Both in cervical and lumbar spine, linear elastic parameters were significantly higher in axSpA patients in comparison with controls, while viscoelastic parameters were significantly lower. Lumbar muscle frequency, stiffness, relaxation, creep and cervical muscle elasticity were fair to strongly correlated (|0.346| < r < |0.774|) with age, functional status, activity of disease, structural damage and quality of life in axSpA patients. Furthermore, moderate to good fitted multivariate models (0.328 < R2 < 0.697) were obtained combining age, conventional metrology, activity of the disease and function for the estimation of cervical and lumbar MMPs. Conclusion: Mechanical properties of spinal muscles of axSpA patients differ from controls. Lumbar and cervical muscles exhibit greater linear elastic properties and lower viscoelastic properties, which are related with age, clinical and psychophysiological features of axSpA.
Collapse
Affiliation(s)
- Juan L. Garrido-Castro
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004 Cordoba, Spain; (J.L.G.-C.); (I.C.A.-V.); (J.P.-A.); (C.G.-N.); (C.L.-M.); (E.C.-E.); (F.A.-S.)
| | - I. Concepción Aranda-Valera
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004 Cordoba, Spain; (J.L.G.-C.); (I.C.A.-V.); (J.P.-A.); (C.G.-N.); (C.L.-M.); (E.C.-E.); (F.A.-S.)
- Department of Rheumatology, University Hospital Reina Sofía, 14004 Cordoba, Spain
- Department of Medical and Surgical Sciences, University of Cordoba, 14004 Cordoba, Spain
| | - José Peña-Amaro
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004 Cordoba, Spain; (J.L.G.-C.); (I.C.A.-V.); (J.P.-A.); (C.G.-N.); (C.L.-M.); (E.C.-E.); (F.A.-S.)
- Department of Morphological and Social Health Sciences, University of Cordoba, 14004 Cordoba, Spain
| | | | - Cristina González-Navas
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004 Cordoba, Spain; (J.L.G.-C.); (I.C.A.-V.); (J.P.-A.); (C.G.-N.); (C.L.-M.); (E.C.-E.); (F.A.-S.)
| | - Daiana P. Rodrigues-de-Souza
- Department of Nursing, Pharmacology and Physical Therapy, University of Cordoba, 14004 Cordoba, Spain; (S.A.-C.); (L.G.-L.)
- Correspondence: ; Tel.: +34-957-218-241
| | - Sandra Alcaraz-Clariana
- Department of Nursing, Pharmacology and Physical Therapy, University of Cordoba, 14004 Cordoba, Spain; (S.A.-C.); (L.G.-L.)
| | - Lourdes García-Luque
- Department of Nursing, Pharmacology and Physical Therapy, University of Cordoba, 14004 Cordoba, Spain; (S.A.-C.); (L.G.-L.)
| | - Iago R. Martínez Sánchez
- Advanced Informatics Research Group (GIIA) TIC-252, University of Cordoba, 14014 Cordoba, Spain;
| | - Clementina López-Medina
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004 Cordoba, Spain; (J.L.G.-C.); (I.C.A.-V.); (J.P.-A.); (C.G.-N.); (C.L.-M.); (E.C.-E.); (F.A.-S.)
- Department of Rheumatology, University Hospital Reina Sofía, 14004 Cordoba, Spain
- Department of Medical and Surgical Sciences, University of Cordoba, 14004 Cordoba, Spain
| | - Eduardo Collantes-Estévez
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004 Cordoba, Spain; (J.L.G.-C.); (I.C.A.-V.); (J.P.-A.); (C.G.-N.); (C.L.-M.); (E.C.-E.); (F.A.-S.)
- Department of Rheumatology, University Hospital Reina Sofía, 14004 Cordoba, Spain
- Department of Medical and Surgical Sciences, University of Cordoba, 14004 Cordoba, Spain
| | - Francisco Alburquerque-Sendín
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004 Cordoba, Spain; (J.L.G.-C.); (I.C.A.-V.); (J.P.-A.); (C.G.-N.); (C.L.-M.); (E.C.-E.); (F.A.-S.)
- Department of Nursing, Pharmacology and Physical Therapy, University of Cordoba, 14004 Cordoba, Spain; (S.A.-C.); (L.G.-L.)
| |
Collapse
|
30
|
Hodgkinson D, Prasad S, Antoun JS, Mei L, Farella M. Biomechanical properties of the lips in a pre-orthodontic sample of adolescents and young adults. Eur J Orthod 2021; 44:232-239. [PMID: 34401897 DOI: 10.1093/ejo/cjab053] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVES To assess biomechanical properties of the lip muscles and to investigate their relationship with sex, age, body mass index (BMI), and cephalometric variables. MATERIALS AND METHODS Demographic information and BMI were collected from 83 study participants seeking orthodontic treatment at the University of Otago. Tone, stiffness, and elasticity of the lip muscles were measured thrice at four different anatomical sites using a digital palpation device. To estimate method error, a duplicate set of measurements in a subsample of 20 participants was taken a week later. Sagittal and vertical cephalometric classifications were based on ANB and FMPA angles, respectively. Data were analysed using mixed models. RESULTS Biomechanical properties of lip muscles were remarkably consistent both within and between different recording sessions. The lower lip had higher tone and stiffness than the upper lip. Both the upper and lower lip stiffness and tone were higher in females than in males, whereas upper lip elasticity was higher in males. Thinner upper lips had higher tone and were stiffer than thicker upper lips, whereas thinner lower lips were less elastic than thicker lower lips. Muscle tone and stiffness of both the upper and lower lips were lower in Class III than in Class I and Class II individuals. The upper lip of hyperdivergent individuals was less elastic than that of normodivergent and hypodivergent individuals, and stiffer than that of hypodivergent individuals. CONCLUSIONS The biomechanical properties of perioral soft tissues can be reliably measured and vary with anatomical site, sex, and cephalometric measurements.
Collapse
Affiliation(s)
- Danielle Hodgkinson
- Discipline of Orthodontics, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Sabarinath Prasad
- Discipline of Orthodontics, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Joseph S Antoun
- Discipline of Orthodontics, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Li Mei
- Discipline of Orthodontics, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Mauro Farella
- Discipline of Orthodontics, Faculty of Dentistry, University of Otago, Dunedin, New Zealand.,Department of Surgical Science, University of Cagliari, Italy
| |
Collapse
|
31
|
Jiménez-Sánchez C, Gómez-Soriano J, Bravo-Esteban E, Mayoral-Del Moral O, Herrero-Gállego P, Serrano-Muñoz D, Ortiz-Lucas M. Effects of Dry Needling on Biomechanical Properties of the Myofascial Trigger Points Measured by Myotonometry: A Randomized Controlled Trial. J Manipulative Physiol Ther 2021; 44:467-474. [PMID: 34376319 DOI: 10.1016/j.jmpt.2021.06.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2019] [Revised: 09/02/2020] [Accepted: 06/15/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVE The purpose of the present study was to examine the effect of dry needling (DN) on the biomechanical properties of a latent medial myofascial trigger point (MTrP) of the soleus muscle compared with an adjacent point within the taut band (TB) measured by myotonometry. METHODS Fifty asymptomatic volunteers were randomly assigned to an intervention group (n = 26) or control group (n = 24). One session of DN was performed in every group as follows: 10 needle insertions into the MTrP area (intervention group) or TB area (control group). Myotonometric measurements (frequency, decrement, and stiffness) were performed at baseline (pre-intervention) and after the intervention (post-intervention) in both locations (MTrP and TB areas). RESULTS The results showed that stiffness outcome significantly decreased with a large effect size after DN in the MTrP when measured in the MTrP location (P = .002; d = 0.928) but not when measured in the TB location. In contrast, no significant changes were observed in any location when the TB was needled (P > .05). CONCLUSIONS The findings suggest that only DN into the MTrP area was effective in decreasing stiffness outcome, therefore a specific puncture was needed to modify myofascial muscle stiffness.
Collapse
Affiliation(s)
| | - Julio Gómez-Soriano
- Toledo Physiotherapy Research Group, Facultad de Fisioterapia de Toledo, Universidad Castilla La Mancha, Toledo, Castilla La Mancha, Spain; Sensorimotor Function Group, Hospital Nacional de Parapléjicos, Toledo, Castilla La Mancha, Spain.
| | - Elisabeth Bravo-Esteban
- Toledo Physiotherapy Research Group, Facultad de Fisioterapia de Toledo, Universidad Castilla La Mancha, Toledo, Castilla La Mancha, Spain
| | | | | | - Diego Serrano-Muñoz
- Toledo Physiotherapy Research Group, Facultad de Fisioterapia de Toledo, Universidad Castilla La Mancha, Toledo, Castilla La Mancha, Spain; Sensorimotor Function Group, Hospital Nacional de Parapléjicos, Toledo, Castilla La Mancha, Spain
| | | |
Collapse
|
32
|
Roth C, Rettenmaier L, Behringer M. High-Protein Energy-Restriction: Effects on Body Composition, Contractile Properties, Mood, and Sleep in Active Young College Students. Front Sports Act Living 2021; 3:683327. [PMID: 34212136 PMCID: PMC8239143 DOI: 10.3389/fspor.2021.683327] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2021] [Accepted: 05/18/2021] [Indexed: 12/15/2022] Open
Abstract
Background: It is often advised to ensure a high-protein intake during energy-restricted diets. However, it is unclear whether a high-protein intake is able to maintain muscle mass and contractility in the absence of resistance training. Materials and Methods: After 1 week of body mass maintenance (45 kcal/kg), 28 male college students not performing resistance training were randomized to either the energy-restricted (ER, 30 kcal/kg, n = 14) or the eucaloric control group (CG, 45 kcal/kg, n = 14) for 6 weeks. Both groups had their protein intake matched at 2.8 g/kg fat-free-mass and continued their habitual training throughout the study. Body composition was assessed weekly using multifrequency bioelectrical impedance analysis. Contractile properties of the m. rectus femoris were examined with Tensiomyography and MyotonPRO at weeks 1, 3, and 5 along with sleep (PSQI) and mood (POMS). Results: The ER group revealed greater reductions in body mass (Δ -3.22 kg vs. Δ 1.90 kg, p < 0.001, partial η 2 = 0.360), lean body mass (Δ -1.49 kg vs. Δ 0.68 kg, p < 0.001, partial η 2 = 0.152), body cell mass (Δ -0.85 kg vs. Δ 0.59 kg, p < 0.001, partial η 2 = 0.181), intracellular water (Δ -0.58 l vs. Δ 0.55 l, p < 0.001, partial η 2 = 0.445) and body fat percentage (Δ -1.74% vs. Δ 1.22%, p < 0.001, partial η 2 = 433) compared to the CG. Contractile properties, sleep onset, sleep duration as well as depression, fatigue and hostility did not change (p > 0.05). The PSQI score (Δ -1.43 vs. Δ -0.64, p = 0.006, partial η 2 = 0.176) and vigor (Δ -2.79 vs. Δ -4.71, p = 0.040, partial η 2 = 0.116) decreased significantly in the ER group and the CG, respectively. Discussion: The present data show that a high-protein intake alone was not able to prevent lean mass loss associated with a 6-week moderate energy restriction in college students. Notably, it is unknown whether protein intake at 2.8 g/kg fat-free-mass prevented larger decreases in lean body mass. Muscle contractility was not negatively altered by this form of energy restriction. Sleep quality improved in both groups. Whether these advantages are due to the high-protein intake cannot be clarified and warrants further study. Although vigor was negatively affected in both groups, other mood parameters did not change.
Collapse
Affiliation(s)
- Christian Roth
- Department of Sports Medicine and Exercise Physiology, Institute of Sport Sciences, Goethe University Frankfurt, Frankfurt, Germany
| | - Lukas Rettenmaier
- Department of Sports Medicine and Exercise Physiology, Institute of Sport Sciences, Goethe University Frankfurt, Frankfurt, Germany
| | - Michael Behringer
- Department of Sports Medicine and Exercise Physiology, Institute of Sport Sciences, Goethe University Frankfurt, Frankfurt, Germany
| |
Collapse
|
33
|
Bravo-Sánchez A, Abián P, Sánchez-Infante J, Esteban-Gacía P, Jiménez F, Abián-Vicén J. Objective Assessment of Regional Stiffness in Vastus Lateralis with Different Measurement Methods: A Reliability Study. SENSORS 2021; 21:s21093213. [PMID: 34066343 PMCID: PMC8125613 DOI: 10.3390/s21093213] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 05/01/2021] [Accepted: 05/03/2021] [Indexed: 12/16/2022]
Abstract
The objective of this study was to evaluate the reliability of four methods of assessing vastus lateralis (VL) stiffness, and to describe the influence of structural characteristics on them. The stiffness of the dominant lower-limb’s VL was evaluated in 53 healthy participants (28.4 ± 9.1 years) with shear wave elastography (SWE), strain elastography (SE), myotonometry and tensiomyography (TMG). The SWE, SE and myotonometry were performed at 50%, and TMG was assessed at 30%, of the length from the upper pole of the patella to the greater trochanter. The thickness of the VL, adipose tissue and superficial connective tissue was also measured with ultrasound. Three repeated measurements were acquired to assess reliability, using intraclass correlation coefficients (ICC). Pearson’s correlation coefficients were calculated to determine the relationships between methodologic assessments and between structural characteristics and stiffness assessments of the VL. Myotonometry (ICC = 0.93; 95%-CI = 0.89,0.96) and TMG (ICC = 0.89; 95%-CI = 0.82,0.94) showed excellent inter-day reliability whereas with SWE (ICC = 0.62; 95%-CI = 0.41,0.77) and SE (ICC = 0.71; 95%-CI = 0.57,0.81) reliability was moderate. Significant correlations were found between myotonometry and VL thickness (r = 0.361; p = 0.008), adipose tissue thickness (r = −0.459; p = 0.001) and superficial connective tissue thickness (r = 0.340; p = 0.013). Myotonometry and TMG showed the best reliability values, although myotonometry stiffness values were influenced by the structural variables of the supra-adjacent tissue.
Collapse
Affiliation(s)
- Alfredo Bravo-Sánchez
- Performance and Sport Rehabilitation Laboratory, Faculty of Sport Sciences, University of Castilla-La Mancha, 45071 Toledo, Spain; (A.B.-S.); (J.S.-I.); (P.E.-G.); (F.J.)
| | - Pablo Abián
- Faculty of Humanities and Social Sciences, Comillas Pontifical University, 28049 Madrid, Spain;
| | - Jorge Sánchez-Infante
- Performance and Sport Rehabilitation Laboratory, Faculty of Sport Sciences, University of Castilla-La Mancha, 45071 Toledo, Spain; (A.B.-S.); (J.S.-I.); (P.E.-G.); (F.J.)
| | - Paula Esteban-Gacía
- Performance and Sport Rehabilitation Laboratory, Faculty of Sport Sciences, University of Castilla-La Mancha, 45071 Toledo, Spain; (A.B.-S.); (J.S.-I.); (P.E.-G.); (F.J.)
| | - Fernando Jiménez
- Performance and Sport Rehabilitation Laboratory, Faculty of Sport Sciences, University of Castilla-La Mancha, 45071 Toledo, Spain; (A.B.-S.); (J.S.-I.); (P.E.-G.); (F.J.)
| | - Javier Abián-Vicén
- Performance and Sport Rehabilitation Laboratory, Faculty of Sport Sciences, University of Castilla-La Mancha, 45071 Toledo, Spain; (A.B.-S.); (J.S.-I.); (P.E.-G.); (F.J.)
- Correspondence: ; Tel.: +34-925268800 (ext. 5522)
| |
Collapse
|
34
|
Effects of a Massage Protocol in Tensiomyographic and Myotonometric Proprieties. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18083891. [PMID: 33917668 PMCID: PMC8067956 DOI: 10.3390/ijerph18083891] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 03/30/2021] [Accepted: 04/03/2021] [Indexed: 12/15/2022]
Abstract
Background: Pre-competition massage is usually used to improve athletic performance and reduce risk of injury. Despite its usual use, the effects of pre-competition massage on neuromuscular function have barely been studied. The aim of this study is to evaluate the effects of the pre-competition massage over the gastrocnemius neuromuscular function. Method: The study is a quasi-experimental clinical trial thirty healthy athletes were enrolled in the study. Subjects received an intervention in one leg (experimental), consisting of a massage, and no intervention in the opposite leg (control). From all values of neuromuscular function, the following were analyzed: contraction time (Tc) and maximal displacement (Dm) by tensiomyography, and stiffness and tone by myotonometry. Results: Main effects of pre-competition massage on neuromuscular function include a significant (p < 0.05) increase in Tc and Dm variables, as well as a reduction in stiffness and tone. Conclusion: Data shows an increase in Tc and maximal radial displacement (Dm) variables, as well as a reduction in stiffness and tone. More quality studies are needed to draw clear conclusions about the effects of pre-competition massage.
Collapse
|
35
|
Lohr C, Medina-Porqueres I. Immediate effects of myofascial release on neuromechanical characteristics in female and male patients with low back pain and healthy controls as assessed by tensiomyography. A controlled matched-pair study. Clin Biomech (Bristol, Avon) 2021; 84:105351. [PMID: 33848704 DOI: 10.1016/j.clinbiomech.2021.105351] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 03/04/2021] [Accepted: 04/01/2021] [Indexed: 02/07/2023]
Abstract
BACKGROUND Low back pain (LBP) is a major health issue in most industrialised countries. Lumbodorsal fascia has been advocated as a potential source of pain in the lumbopelvic region. Myofascial release constitutes a manual therapeutic approach focussing on the restoration of altered soft tissue function. No previous study has focused on quantifying neuromechanical effects of myofascial release on LBP patients through tensiomyography. The purpose of this study was to quantify immediate neuromechanical alterations of myofascial release on patients with LBP and healthy controls through tensiomyography parameters. METHODS The participants' (n = 30) bilateral lumbar erector spinae muscles were assessed via tensiomyography before and after a 6-min myofascial release treatment of the lumbodorsal fascia to evaluate the muscles' mechanical characteristics. Subjects with LBP (n = 15) were eligible to partake if they reported having had LBP for most days in the past 12 weeks. Muscle displacement (Dm [mm]), velocity of contraction (Vc [mm/s]), and lateral symmetry (Ls [%]) were assessed through tensiomyography testing. FINDINGS Statistical analyses revealed a significant increase for velocity of contraction in the right (p = .021) and left (p = .041) lumbar erector spinae for the subjects with LBP but not for the healthy controls (both p > .14). INTERPRETATION We suggested that myofascial release alters neuromechanical characteristics in subjects with LBP. Tensiomyography may be implemented in clinical settings to monitor intervention effects of the myofascial system, especially the tensiomyography parameter velocity of contraction.
Collapse
Affiliation(s)
- Christine Lohr
- Department of Sports and Exercise Medicine, Institute for Human Movement Science, Faculty for Psychology and Human Movement Science, University of Hamburg, Hamburg, Germany.
| | - Ivan Medina-Porqueres
- Department of Physical Therapy, Faculty of Health Sciences, University of Malaga, Malaga, Spain.
| |
Collapse
|
36
|
Labata-Lezaun N, López-de-Celis C, Llurda-Almuzara L, González-Rueda V, Cadellans-Arróniz A, Pérez-Bellmunt A. Correlation between maximal radial muscle displacement and stiffness in gastrocnemius muscle. Physiol Meas 2020; 41:125013. [PMID: 33238250 DOI: 10.1088/1361-6579/abcdf4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
OBJECTIVE Tensiomyography (TMG) and myotonometry (MMT) are two novel technologies that measure neuromuscular properties. These two devices measure the stiffness of the soft tissue as well as other variables. The aim of this study is to analyze if there is any correlation between maximal radial displacement (Dm) and Stiffness in the medial and lateral gastrocnemius muscles. APPROACH An observational study was carried out in both of the limbs of 154 young adults (n = 154). The TMG and MMT neuromuscular response was measured in gastrocnemius medial and lateral muscles. Correlation coefficients were calculated to observe if there were any relationships between Dm and Stiffness. Differences between the dominant and the non-dominant sides and gender were assessed. MAIN RESULTS Negative correlations between Dm versus Stiffness were found for the lateral (r = -0.278 and rho = -0.248) and medial gastrocnemius (r = -0.207 and rho = -0.163) in both dominant and non-dominant limbs respectively. SIGNIFICANCE A weak correlation between Dm and Stiffness may indicate that they assess different aspects of neuromuscular function. The MMT and TMG are independent tools, and their values cannot be extrapolated when assessing muscular stiffness. There might be some other factors that influence in this relationship; therefore, more studies are needed in order to better understand the correlation.
Collapse
Affiliation(s)
- Noé Labata-Lezaun
- Anatomy Unit. Basic Sciences department. Universitat Internacional de Catalunya, Spain
| | | | | | | | | | | |
Collapse
|
37
|
López-de-Celis C, Pérez-Bellmunt A, Bueno-Gracia E, Fanlo-Mazas P, Zárate-Tejero CA, Llurda-Almuzara L, Cadellans Arróniz A, Rodriguez-Rubio PR. Effect of diacutaneous fibrolysis on the muscular properties of gastrocnemius muscle. PLoS One 2020; 15:e0243225. [PMID: 33296423 PMCID: PMC7725309 DOI: 10.1371/journal.pone.0243225] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Accepted: 11/17/2020] [Indexed: 01/01/2023] Open
Abstract
Diacutaneous fibrolysis is a noninvasive technique that has been shown to be effective in the treatment of musculoskeletal disorders such as shoulder pain, lateral epicondylalgia, patellofemoral pain syndrome and carpal tunnel syndrome. However, while diacutaneous fibrolysis is applied to soft tissue, its effects on muscular properties are unknown. The purpose of the present study was to evaluate the effects of diacutaneous fibrolysis on muscle properties as measured by tensiomyography and myotonometry in asymptomatic subjects. An analytical descriptive study was performed. A single session of diacutaneous fibrolysis on the gastrocnemius muscle was applied to one limb (treated limb group) and the other limb was the control (control limb group). Subjects were assessed with tensiomyography and myotonometry before treatment (T0), after treatment (T1) and 30 minutes later (T2). The primary outcomes were tensiomyography and myotonometry variables. The treated limb group showed a statistically significant increase (p<0.05) in tensiomyography parameters. A decrease in rigidity and increase in relaxation was also observed on myotonometry at T1, with some of the effects being maintained at T2. Rigidity and relaxation at T1 were statistically significant between groups (p<0.05). A single session of diacutaneous fibrolysis to the gastrocnemius muscle of asymptomatic subjects produced immediate changes in muscle properties. These changes were maintained 30 minutes after the application of the technique.
Collapse
Affiliation(s)
- Carlos López-de-Celis
- Departamento de Fisioterapia, Universitat Internacional de Catalunya, Barcelona, Spain
- Institut Universitari de Investigació en Atenció Primària (IDIAP Jordi Gol), Barcelona, Spain
| | - Albert Pérez-Bellmunt
- Departamento de Fisioterapia, Universitat Internacional de Catalunya, Barcelona, Spain
| | - Elena Bueno-Gracia
- Departamento de Fisiatría y Enfermería, Universidad de Zaragoza, Zaragoza, Spain
- * E-mail:
| | - Pablo Fanlo-Mazas
- Departamento de Fisiatría y Enfermería, Universidad de Zaragoza, Zaragoza, Spain
| | | | - Luis Llurda-Almuzara
- Departamento de Fisioterapia, Universitat Internacional de Catalunya, Barcelona, Spain
| | | | | |
Collapse
|
38
|
Normative data and correlation between dynamic knee valgus and neuromuscular response among healthy active males: a cross-sectional study. Sci Rep 2020; 10:17206. [PMID: 33268811 PMCID: PMC7710730 DOI: 10.1038/s41598-020-74177-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2020] [Accepted: 09/28/2020] [Indexed: 02/07/2023] Open
Abstract
The dynamic knee valgus (DKV) during different sport maneuvers has been widely described as risk factor to develop an anterior cruciate ligament injury. Hip and knee muscles seem to have a crucial role to prevent the dynamic knee valgus. This study aimed to give normative and correlational data about DKV and hip and knee neuromuscular response (NMR) among healthy active males. The hypothesis is that DKV could be correlated with hip NMR. A cross-sectional correlational study. Research Anatomy Laboratory. The study was carried out among 50 active, non-injured males. Dynamic Knee-Valgus angle and lower limb posterior chain muscles Neuromuscular Response. DKV was measured using Kinovea software during a Single-Legged Drop Jump test and NMR was measured using tensiomyography and myotonometry for gluteus maximum, biceps femoris, semitendinosus, lateral and medial gastrocnemius. Right and left limbs were both performed and analyzed independently. No significant correlation was observed between DKV and hip and knee muscles NMR. This study shows normative and correlational data about dynamic knee valgus, tensiomyography and myotonometry for healthy and active males. The DKV control seems to be non-correlated with isolated hip and knee muscles NMR so this suggests it is more about Central Nervous System activity than about isolated muscles NMR.
Collapse
|
39
|
Tennant LM, Nelson-Wong E, Kuest J, Lawrence G, Levesque K, Owens D, Prisby J, Spivey S, Albin SR, Jagger K, Barrett JM, Wong JD, Callaghan JP. A Comparison of Clinical Spinal Mobility Measures to Experimentally Derived Lumbar Spine Passive Stiffness. J Appl Biomech 2020; 36:397-407. [PMID: 33049702 DOI: 10.1123/jab.2020-0030] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Revised: 05/12/2020] [Accepted: 06/17/2020] [Indexed: 11/18/2022]
Abstract
Spinal stiffness and mobility assessments vary between clinical and research settings, potentially hindering the understanding and treatment of low back pain. A total of 71 healthy participants were evaluated using 2 clinical assessments (posteroanterior spring and passive intervertebral motion) and 2 quantitative measures: lumped mechanical stiffness of the lumbar spine and local tissue stiffness (lumbar erector spinae and supraspinous ligament) measured via myotonometry. The authors hypothesized that clinical, mechanical, and local tissue measures would be correlated, that clinical tests would not alter mechanical stiffness, and that males would demonstrate greater lumbar stiffness than females. Clinical, lumped mechanical, and tissue stiffness were not correlated; however, gradings from the posteroanterior spring and passive intervertebral motion tests were positively correlated with each other. Clinical assessments had no effect on lumped mechanical stiffness. The males had greater lumped mechanical and lumbar erector spinae stiffness compared with the females. The lack of correlation between clinical, tissue, and lumped mechanical measures of spinal stiffness indicates that the use of the term "stiffness" by clinicians may require reevaluation; clinicians should be confident that they are not altering mechanical stiffness of the spine through segmental mobility assessments; and greater resting lumbar erector stiffness in males suggests that sex should be considered in the assessment and treatment of the low back.
Collapse
|
40
|
Muscle excitation, force response, and efficiency during explosive force production after diacutaneous fibrolysis on lateral gastrocnemius of recreational athletes. J Bodyw Mov Ther 2020; 24:554-560. [PMID: 33218560 DOI: 10.1016/j.jbmt.2020.08.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Revised: 07/20/2020] [Accepted: 08/08/2020] [Indexed: 11/23/2022]
Abstract
OBJECTIVE Fibrous adhesions impair normal muscle mechanics. The present study aimed to assess lateral gastrocnemius muscle excitation, isometric force response, and neuromuscular efficiency during explosive force in plantarflexion before and after diacutaneous fibrolysis. METHODS Thirty-five recreational athletes were allocated in the intervention group (n = 20) treated with diacutaneous fibrolysis, while the sham group (n = 15) was treated with placebo diacutaneous fibrolysis. Force response synchronized with surface electromyography during a plantarflexion task was collected. RESULTS Differences between Pre- and Post-diacutaneous fibrolysis were observed for all variables, except for the placebo group. CONCLUSIONS Diacutaneous fibrolysis was effective to increase force, muscle excitation, and neuromuscular efficiency on lateral gastrocnemius.
Collapse
|
41
|
Lohr C, Schmidt T, Braumann KM, Reer R, Medina-Porqueres I. Sex-Based Differences in Tensiomyography as Assessed in the Lower Erector Spinae of Healthy Participants: An Observational Study. Sports Health 2020; 12:341-346. [PMID: 32511080 DOI: 10.1177/1941738120917932] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Although there is mounting evidence on sex-linked differences in paraspinal muscle function, it is unknown whether sex-based variations in mechanical and contractile characteristics of the lumbar erector spinae (LES) can be monitored noninvasively in healthy participants at rest using tensiomyography (TMG). HYPOTHESIS Sex-specific effects in muscle displacement (Dm) and velocity of muscle deformation (Vd) will be observed via TMG assessed in the LES. STUDY DESIGN Observational study. LEVEL OF EVIDENCE Level 3. METHODS LES response was measured in a relaxed state in 40 healthy adults (20 females). Possible differences between the conditions were investigated using mixed-model analyses of variance. Two-stage hierarchical linear regression analyses were performed to predict the outcome of TMG Dm and Vd based on participant sex. RESULTS There were significant main effects of sex with large effect sizes for both TMG parameters, resulting from lower mean values in women compared with men (Dm, P < 0.01; Vd, P < 0.01). In contrast, neither the main effect of side (left vs right LES) nor the interaction between the side and sex reached significance (all P > 0.3). Introducing the sex variable in stage 2 of the regression analyses significantly improved the prediction of the TMG parameters (all ∆R2 ≥ 0.18; all P < 0.01; all f2 ≥ 0.29). CONCLUSION Sex-based differences in muscle stiffness and contractile characteristics could be observed by TMG on LES muscles in healthy individuals at rest. The data suggest that these disparities are not exclusively attributable to anthropometric measures but may be linked to intrinsic sex-based differences in skeletal muscle characteristics. CLINICAL RELEVANCE We recommend implementing TMG in a clinical setting using the obtained results as a basis to factor for the patient's biological sex when assessing effects of therapeutic/exercise regimens aiming at the optimization of myofascial tissue regeneration and performance.
Collapse
Affiliation(s)
- Christine Lohr
- Department of Sports Medicine, Institute for Human Movement Science, Faculty for Psychology and Human Movement Science, University of Hamburg, Hamburg, Germany
| | - Tobias Schmidt
- Department of Sports Medicine, Institute for Human Movement Science, Faculty for Psychology and Human Movement Science, University of Hamburg, Hamburg, Germany.,Department of General Practice, University Medical Center Göttingen, Göttingen, Germany.,Osteopathie Schule Deutschland (OSD) Hamburg, Hamburg, Germany
| | - Klaus-Michael Braumann
- Department of Sports Medicine, Institute for Human Movement Science, Faculty for Psychology and Human Movement Science, University of Hamburg, Hamburg, Germany
| | - Rüdiger Reer
- Department of Sports Medicine, Institute for Human Movement Science, Faculty for Psychology and Human Movement Science, University of Hamburg, Hamburg, Germany
| | - Ivan Medina-Porqueres
- Department of Physical Therapy, Faculty of Health Sciences, University of Malaga, Malaga, Spain
| |
Collapse
|
42
|
Piqueras-Sanchiz F, Martín-Rodríguez S, Pareja-Blanco F, Baraja-Vegas L, Blázquez-Fernández J, Bautista IJ, García-García Ó. Mechanomyographic Measures of Muscle Contractile Properties are Influenced by Electrode Size and Stimulation Pulse Duration. Sci Rep 2020; 10:8192. [PMID: 32424300 PMCID: PMC7235246 DOI: 10.1038/s41598-020-65111-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2019] [Accepted: 04/27/2020] [Indexed: 11/22/2022] Open
Abstract
The aim was to determine the effects of changing pulse duration and electrode size on muscle contractile properties. Thirty-six healthy young male participated in the study (age 24.8 ± 5.8 years; height 178.2 ± 0.6 cm; body mass 71.8 ± 7.3 kg; self-reported weekly moderate intensity activity 3.5 ± 1.2 h·week−1). Tensiomyography was used to assess rectus femoris (RF) and vastus medialis (VM) muscles neuromuscular properties of the dominant leg according to the electrode size (3.2–5 cm) and the stimulus length (0.2, 0.5, and 1 ms). Maximal radial displacement (Dm); Contraction time (Tc); Delay time (Td); Sustained time (Ts) and Half relaxation time (Tr) were measured. Relative and absolute reliability was quantified. To analyze the effects of the electrode and the stimulus length, a repeated-measures analysis of variance was used. Dm and Tc parameters showed for both muscles an excellent relative (0.95–0.99) and absolute reliability (1.6–4.2%). However, Ts and Tr showed low values of absolute reliability (4.4–40.9%). The duration of the stimulus length applied to the RF and VM and electrode size significantly influences muscle’s contractile properties (p < 0.05; η2p = 0.09–0.60). The Dm increases substantially as the duration of the stimulus increases and with the use of the larger electrode in both muscles. However, Tc and Td are less affected by both conditions and not entirely clear. Practically, our study suggests that a stimulus pulse duration of 1 ms together with a 5 × 5 cm electrode is necessary to reach a reliable and reproducible assessment of both RF and VM muscles contractile properties.
Collapse
Affiliation(s)
| | - Saúl Martín-Rodríguez
- Department of Physical Education, University of Las Palmas de Gran Canaria, Las Palmas de Gran Canaria, Spain
| | - Fernando Pareja-Blanco
- Physical Performance & Sports Research Center, Universidad Pablo de Olavide, Seville, Spain
| | - Luis Baraja-Vegas
- Department of Physiotherapy, Catholic University of Valencia, Valencia, Spain
| | | | - Iker J Bautista
- Faculty of Physiotherapy and Podology, Catholic University of Valencia, Valencia, Spain
| | - Óscar García-García
- Laboratory of Sports Performance, Physical Condition and Wellness, Faculty of Education and Sport Sciences, Universidade de Vigo, Pontevedra, Spain.
| |
Collapse
|
43
|
Quantified biomechanical properties of lower lumbar myofascia in younger adults with chronic idiopathic low back pain and matched healthy controls. Clin Biomech (Bristol, Avon) 2020; 73:78-85. [PMID: 31954272 DOI: 10.1016/j.clinbiomech.2019.12.026] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Revised: 11/08/2019] [Accepted: 12/27/2019] [Indexed: 02/07/2023]
Abstract
BACKGROUND Non-specific chronic low back pain (LBP) is a prevalent condition that is poorly understood with respect to possible altered physical properties. Five biomechanical properties of stiffness, frequency, decrement, creep, and stress relaxation time of the L3-L4 myofascial tissue were quantified using the MyotonPro® in chronic idiopathic LBP and matched normal control subjects. METHODS Measurements were obtained in the resting prone position on the left and right sides (initially and after 10 min rest) in 25 chronic LBP participants (16 female, 9 male) and 25 age- and sex-matched control subjects. Surface electromyography measurements were simultaneously conducted to ensure a resting state. FINDINGS Female LBP had significantly greater median decrement (p < 0.001) and stiffness (p < 0.010) than female controls. In female LBP patients, BMI correlated with decrement (p < 0.010) and creep (p < 0.050); creep also correlated with decrement (p < 0.050). Significant male versus female differences were found in all five properties in both LBP and control subgroups, except decrement in control males versus females. INTERPRETATION This study showed that greater median decrement was found in LBP female subjects suggesting decrease in elasticity in the lumbar myofascia. Most of the biomechanical properties differed significantly by gender. This study further documented that right-handed dominance might correlate with greater right-sided lumbar myofascial stiffness.
Collapse
|
44
|
Martín-San Agustín R, Medina-Mirapeix F, Casaña-Granell J, García-Vidal JA, Lillo-Navarro C, Benítez-Martínez JC. Tensiomyographical responsiveness to peripheral fatigue in quadriceps femoris. PeerJ 2020; 8:e8674. [PMID: 32161690 PMCID: PMC7050546 DOI: 10.7717/peerj.8674] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Accepted: 01/31/2020] [Indexed: 12/27/2022] Open
Abstract
Background Fatigue influences athletic performance and can also increase the risk of injury in sports, and most of the methods to evaluate it require an additional voluntary effort. Tensiomyography (TMG), which uses electrical stimulation and a displacement sensor to evaluate muscle contraction properties of one or more muscle bellies, has emerged as a technique that can assess the presence of peripheral and central fatigue without requiring additional voluntary efforts. However, the evaluation of the TMG’s ability to detect fatigue is limited, both at the level of muscle bellies and statistical methods. Thus, the aim of the present study was twofold: (i) to examine and compare the tensiomyographical responsiveness to quadriceps femoris (QF) fatigue by multiple statistical methods and (ii) to analyze sex differences in the variation produced by fatigue in TMG parameters. Methods Thirty-nine recreational athletes participated (19 males/20 females; aged 22 ± 2 years). TMG parameters of QF bellies and maximal voluntary isometric contraction (MVIC) were measured before and after a fatigue protocol. TMG parameters used were maximum radial deformation (Dm), contraction time between 10–90% of the Dm (Tc), contraction velocity between 10–90% (Vc) and of the first 10% (V10) of the Dm. Internal responsiveness of TMG to fatigue was analyzed by paired t-test and standardized response mean (SRM). External responsiveness was examined by correlations, regression models, and receiver operating characteristic (ROC) curves. Results All TMG parameters, except for Tc of rectus femoris and vastus medialis, showed large internal responsiveness. In adjusted regression models by sex, only Dm and V10 of rectus femoris were statistically associated (p < 0.05) with b coefficients of 0.40 and 0.43, respectively. r2 explained the 22% of the total variance. In addition, these parameters could discriminate between QF with and without fatigue. Conclusion Since the QF is the main strength contributor during multiple physical activities, clinicians and trainers will be able to discriminate the presence of fatigue and the magnitude of changes in the QF strength by TMG evaluation.
Collapse
Affiliation(s)
| | | | | | | | - Carmen Lillo-Navarro
- Department of Pathology and Surgery, University Miguel Hernández, San Joan, Spain
| | | |
Collapse
|
45
|
Wu Z, Zhu Y, Xu W, Liang J, Guan Y, Xu X. Analysis of Biomechanical Properties of the Lumbar Extensor Myofascia in Elderly Patients with Chronic Low Back Pain and That in Healthy People. BIOMED RESEARCH INTERNATIONAL 2020; 2020:7649157. [PMID: 32149135 PMCID: PMC7049445 DOI: 10.1155/2020/7649157] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/21/2019] [Revised: 10/04/2019] [Accepted: 01/09/2020] [Indexed: 11/17/2022]
Abstract
There is limited research on the changes of biomechanical characteristics of the lumbar extensor myofascia in elderly patients with chronic low back pain. This study aimed to compare the biomechanical properties of the lumbar extensor myofascia in elderly patients with chronic low back pain and healthy people when resting and to analyze the relationship between the Japanese Orthopedic Association (JOA) score, visual analog scale (VAS) score, Cobb angle, and disease course and the biomechanical characteristics of the lumbar extensor myofascia. This case-control study included 40 elderly patients with chronic low back pain and 40 healthy volunteers. MyotonPRO was used to measure the biomechanical properties of the bilateral lumbar extensor myofascia (at L3/L4 level) in all participants, and the reliability of the MyotonPRO test was measured. Cobb angle was measured from lumbar computed tomography or magnetic resonance imaging data. JOA and VAS scores were used to evaluate lumbar function and pain. We found that muscle tone, stiffness, and elasticity of the left and right lumbar extensor myofascia in patients with chronic low back pain were very reliable among different operators. The average lumbar extensor muscle tone and stiffness were significantly higher in patients with chronic low back pain than those in healthy controls. The average elasticity of the lumbar extensor myofascia of patients with chronic low back pain was significantly lower than that of the healthy controls. The JOA score was negatively correlated, while the VAS score was positively correlated with the mean values of tone, stiffness, and elasticity of the bilateral lumbar extensor myofascia (logarithmic decrement). Disease course had no significant correlation with muscle tone, stiffness, and elasticity of the lumbar extensor myofascia. No significant correlation was found between Cobb angle and muscle tone, stiffness, and elasticity of the lumbar extensor myofascia in either group.
Collapse
Affiliation(s)
- Zugui Wu
- The Fifth Clinical College of Guangzhou University of Chinese Medicine, Guangzhou 510000, China
| | - Yue Zhu
- Baishui Town Health Center, Zhanyi District, Qujing 655000, China
| | - Wu Xu
- Guangdong Provincial Second Hospital of Traditional Chinese Medicine, Guangzhou 510000, China
| | - Junquan Liang
- Guangzhou University of Chinese Medicine, Guangzhou 510000, China
| | - Yingxin Guan
- The Fifth Clinical College of Guangzhou University of Chinese Medicine, Guangzhou 510000, China
| | - Xuemeng Xu
- Guangdong Provincial Second Hospital of Traditional Chinese Medicine, Guangzhou 510000, China
| |
Collapse
|
46
|
Timanin EM, Potekhina YP, Mokhov DE. Studies of the Viscoelastic Characteristics of the Muscles of the Neck and Upper Thorax by the Method of Vibrational Viscoelastometry. BIOMEDICAL ENGINEERING 2020. [DOI: 10.1007/s10527-020-09937-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
47
|
An investigation of the sex-related differences in the stiffness of the Achilles tendon and gastrocnemius muscle: Inter-observer reliability and inter-day repeatability and the effect of ankle joint motion. Foot (Edinb) 2019; 41:44-50. [PMID: 31704588 DOI: 10.1016/j.foot.2019.09.003] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Revised: 09/02/2019] [Accepted: 09/25/2019] [Indexed: 02/04/2023]
Abstract
PURPOSE The purpose of the present study was to investigate sex-related differences in the stiffness of the Achilles tendon and gastrocnemius muscle at rest and tensioned state. Another purpose of the study was to investigate the inter-observer reliability and inter-day repeatability of MyotonPRO, a portable myotonometer, in measuring tendon and muscle stiffness. METHODS The study included 73 healthy participants (19 males for the reliability and repeatability study; 24 males and 30 females for the experimental study) with an age range of 19-27 years. The stiffness of the Achilles tendon and medial gastrocnemius muscle was measured with a portable myotonometer (MyotonPRO). The stiffness measurements of the Achilles tendon and medial gastrocnemius muscle were performed at 0° and 10° of ankle joint dorsiflexion. The stiffness measurements were performed by two physiotherapists to determine the inter-observer reliability of the device. For the inter-day repeatability (or between-day precision), the same individuals were reassessed by the same examiner after a 3-day interval. RESULTS It was found that MyotonPRO has excellent inter-observer reliability and inter-day repeatability in measuring the stiffness of the Achilles tendon and medial gastrocnemius muscle (ICC=0.83-0.98). The stiffness of the Achilles tendon and gastrocnemius muscle at neutral and 10° joint dorsiflexion was higher in males compared to females (p<0.05); however, the stiffness value of difference between neutral and 10° joint dorsiflexion for the Achilles tendon and gastrocnemius muscle was similar in both groups (p>0.05). DISCUSSION The obtained results suggest that MyotonPRO is a reliable and repeatable device in measuring the stiffness of the Achilles tendon and gastrocnemius muscle. Furthermore, males have stiffer Achilles tendon and gastrocnemius muscle, compared to females; however, the change in the stiffness of the assessed tissues caused by joint motion was similar in both sexes.
Collapse
|
48
|
Lohr C, Schmidt T, Medina-Porqueres I, Braumann KM, Reer R, Porthun J. Diagnostic accuracy, validity, and reliability of Tensiomyography to assess muscle function and exercise-induced fatigue in healthy participants. A systematic review with meta-analysis. J Electromyogr Kinesiol 2019; 47:65-87. [DOI: 10.1016/j.jelekin.2019.05.005] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2018] [Revised: 03/16/2019] [Accepted: 05/03/2019] [Indexed: 02/04/2023] Open
|
49
|
Test-retest reliability of elbow flexor contraction characteristics with tensiomyography for different elbow joint angles. J Electromyogr Kinesiol 2019; 45:26-32. [PMID: 30776725 DOI: 10.1016/j.jelekin.2019.02.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2018] [Revised: 01/24/2019] [Accepted: 02/08/2019] [Indexed: 12/22/2022] Open
Abstract
Tensiomyography (TMG) has gained popularity as a tool to quantify muscle contractile properties. However, it is unclear whether joint angle and inter-stimulus interval influence the test-retest reliability of TMG. Fifteen participants (13M/2F; 29.5 ± 7.4 y) underwent TMG recording of the biceps brachii (BB) at 10°, 45° and 90° of elbow flexion with 10 and 20 s inter-stimulus rest intervals in a randomised order on two separate days. The intra-class correlation coefficient (ICC2,1) and 95% confidence interval (95%CI) were calculated for delay time (Td), contraction time (Tc), sustain time (Ts), relaxation time (Tr) and maximal displacement (Dm). Additionally, the standard error of measurement (SEM), coefficient of variation (CV) and minimal detectable change (MDC) were obtained. Across conditions the ICC2,1 varied for each parameter (Td:0.465-0.947, Tc:0.452-0.831, Ts:0.717-0.918, Tr:0.841-0.935, Dm:0.646-0.900). CV was low for Td (2.1-3.0%), Tc (4.4-7.7%) and Ts (5.5-6.9%) but greater for Tr (10.0-15.3%) and Dm (5.8-13.1%) across conditions. Ts (∼210 ms, P < 0.001) and Dm (∼17 mm, P < 0.001) were greatest at 10° and 90°, respectively, while Td was shortest (∼22.9 ms, P = 0.002) at 10° compared to other angles. No differences were observed between inter-stimulus intervals or day. The findings are expected to help shape best practice methods for TMG use in field and research based settings.
Collapse
|
50
|
Jiménez-Sánchez C, Ortiz-Lucas M, Bravo-Esteban E, Mayoral-del Moral O, Herrero-Gállego P, Gómez-Soriano J. Myotonometry as a measure to detect myofascial trigger points: an inter-rater reliability study. Physiol Meas 2018; 39:115004. [DOI: 10.1088/1361-6579/aae9aa] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|