1
|
Burati M, Tagliabue F, Lomonaco A, Chiarelli M, Zago M, Cioffi G, Cioffi U. Artificial intelligence as a future in cancer surgery. Artif Intell Cancer 2022; 3:11-16. [DOI: 10.35713/aic.v3.i1.11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Revised: 12/24/2021] [Accepted: 01/17/2022] [Indexed: 02/06/2023] Open
Affiliation(s)
- Morena Burati
- Department of Robotic and Emergency Surgery, Ospedale A Manzoni, ASST Lecco, Lecco 23900, Italy
| | - Fulvio Tagliabue
- Department of Robotic and Emergency Surgery, Ospedale A Manzoni, ASST Lecco, Lecco 23900, Italy
| | - Adriana Lomonaco
- Department of Robotic and Emergency Surgery, Ospedale A Manzoni, ASST Lecco, Lecco 23900, Italy
| | - Marco Chiarelli
- Department of Robotic and Emergency Surgery, Ospedale A Manzoni, ASST Lecco, Lecco 23900, Italy
| | - Mauro Zago
- Department of Robotic and Emergency Surgery, Ospedale A Manzoni, ASST Lecco, Lecco 23900, Italy
| | - Gerardo Cioffi
- Department of Sciences and Technologies, Unisannio, Benevento 82100, Italy
| | - Ugo Cioffi
- Department of Surgery, University of Milan, Milano 20122, Italy
| |
Collapse
|
2
|
Solanki SL, Pandrowala S, Nayak A, Bhandare M, Ambulkar RP, Shrikhande SV. Artificial intelligence in perioperative management of major gastrointestinal surgeries. World J Gastroenterol 2021; 27:2758-2770. [PMID: 34135552 PMCID: PMC8173379 DOI: 10.3748/wjg.v27.i21.2758] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2021] [Revised: 04/06/2021] [Accepted: 04/28/2021] [Indexed: 02/06/2023] Open
Abstract
Artificial intelligence (AI) demonstrated by machines is based on reinforcement learning and revolves around the usage of algorithms. The purpose of this review was to summarize concepts, the scope, applications, and limitations in major gastrointestinal surgery. This is a narrative review of the available literature on the key capabilities of AI to help anesthesiologists, surgeons, and other physicians to understand and critically evaluate ongoing and new AI applications in perioperative management. AI uses available databases called "big data" to formulate an algorithm. Analysis of other data based on these algorithms can help in early diagnosis, accurate risk assessment, intraoperative management, automated drug delivery, predicting anesthesia and surgical complications and postoperative outcomes and can thus lead to effective perioperative management as well as to reduce the cost of treatment. Perioperative physicians, anesthesiologists, and surgeons are well-positioned to help integrate AI into modern surgical practice. We all need to partner and collaborate with data scientists to collect and analyze data across all phases of perioperative care to provide clinical scenarios and context. Careful implementation and use of AI along with real-time human interpretation will revolutionize perioperative care, and is the way forward in future perioperative management of major surgery.
Collapse
Affiliation(s)
- Sohan Lal Solanki
- Department of Anesthesiology, Critical Care and Pain, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai 400012, Maharashtra, India
| | - Saneya Pandrowala
- Gastro-Intestinal Services, Department of Surgical Oncology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai 400012, Maharashtra, India
| | - Abhirup Nayak
- Department of Anesthesiology, Critical Care and Pain, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai 400012, Maharashtra, India
| | - Manish Bhandare
- Gastro-Intestinal Services, Department of Surgical Oncology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai 400012, Maharashtra, India
| | - Reshma P Ambulkar
- Department of Anesthesiology, Critical Care and Pain, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai 400012, Maharashtra, India
| | - Shailesh V Shrikhande
- Gastro-Intestinal Services, Department of Surgical Oncology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai 400012, Maharashtra, India
| |
Collapse
|
3
|
Rotter N, Schmitz B, Sommer F, Röhrer S, Schuler PJ, Bischof F, Scheithauer MO, Hoffmann TK. First use of flat-panel computed tomography during cochlear implant surgery : Perspectives for the use of advanced therapies in cochlear implantation. HNO 2017; 65:61-65. [PMID: 27534759 DOI: 10.1007/s00106-016-0213-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
BACKGROUND Cochlear implantation in routine cases with normal anatomy is commonly performed without intraoperative image guidance. Revision cochlear implantation as well as surgery in malformations require not only a precise understanding of the underlying complex anatomy, but surgeons need to transform two-dimensional computed tomography (2D CT) scans into the surgical field and use this information for intraoperative surgical navigation. So far, information about the exact position of the electrode during insertion cannot be provided to the surgeon. Here, we present our first operative experience with cochlear implant surgery supported by intraoperative Dyna-CT technology, providing the surgeon with detailed views of the electrode location. METHODS To prove the feasibility of the procedure, two cases of cochlear implantation were performed with intraoperative application of cone-beam CT acquired by a C-arm Dyna-CT system (Artis Zeego, Siemens Healthcare, Erlangen, Germany). Image reconstruction was performed intraoperatively in order to assess the correct positioning of the electrodes. RESULTS Intraoperative Dyna-CT enabled clear visualization of the surgical anatomy and intracochlear electrode position. Dyna-CT technology can be applied with acceptable additional time requirements without adding too much complexity to the surgical procedure. CONCLUSION Intraoperative data acquisition by Dyna-CT represents a suitable option for online surgical navigation during cochlear implant surgery. This imaging technology will push further advances in cochlear implant surgery and lateral skull base surgery, particularly if linked to intraoperative navigation.
Collapse
Affiliation(s)
- N Rotter
- Department of Otorhinolaryngology, Head and Neck Surgery, Ulm University Medical Center, Frauensteige 12, 89075, Ulm, Germany.
| | - B Schmitz
- Department of Diagnostic and Interventional Radiology, Ulm University Medical Center, Ulm, Germany
| | - F Sommer
- Department of Otorhinolaryngology, Head and Neck Surgery, Ulm University Medical Center, Frauensteige 12, 89075, Ulm, Germany
| | - S Röhrer
- Department of Neurosurgery, Ulm University Medical Center, Ulm, Germany
| | - P J Schuler
- Department of Otorhinolaryngology, Head and Neck Surgery, Ulm University Medical Center, Frauensteige 12, 89075, Ulm, Germany
| | - F Bischof
- Department of Otorhinolaryngology, Head and Neck Surgery, Ulm University Medical Center, Frauensteige 12, 89075, Ulm, Germany
| | - M O Scheithauer
- Department of Otorhinolaryngology, Head and Neck Surgery, Ulm University Medical Center, Frauensteige 12, 89075, Ulm, Germany
| | - T K Hoffmann
- Department of Otorhinolaryngology, Head and Neck Surgery, Ulm University Medical Center, Frauensteige 12, 89075, Ulm, Germany
| |
Collapse
|
4
|
Cui L, Gu G, Ye L, Liu B, Shao J, Liu C, Zheng Y. An evaluation on novel application of cone-beam CT imaging with multi-volume technique in carotid body tumor. Eur Arch Otorhinolaryngol 2016; 274:1713-1720. [DOI: 10.1007/s00405-016-4405-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Accepted: 11/23/2016] [Indexed: 10/20/2022]
|
5
|
[Intraoperative multidimensional visualization]. Chirurg 2016; 87:1015-1024. [PMID: 27796416 DOI: 10.1007/s00104-016-0314-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Modern intraoperative techniques of visualization are increasingly being applied in general and visceral surgery. The combination of diverse techniques provides the possibility of multidimensional intraoperative visualization of specific anatomical structures. Thus, it is possible to differentiate between normal tissue and tumor tissue and therefore exactly define tumor margins. The aim of intraoperative visualization of tissue that is to be resected and tissue that should be spared is to lead to a rational balance between oncological and functional results. Moreover, these techniques help to analyze the physiology and integrity of tissues. Using these methods surgeons are able to analyze tissue perfusion and oxygenation. However, to date it is not clear to what extent these imaging techniques are relevant in the clinical routine. The present manuscript reviews the relevant modern visualization techniques focusing on intraoperative computed tomography and magnetic resonance imaging as well as augmented reality, fluorescence imaging and optoacoustic imaging.
Collapse
|
6
|
Kenngott HG, Wagner M, Nickel F, Wekerle AL, Preukschas A, Apitz M, Schulte T, Rempel R, Mietkowski P, Wagner F, Termer A, Müller-Stich BP. Computer-assisted abdominal surgery: new technologies. Langenbecks Arch Surg 2015; 400:273-81. [PMID: 25701196 DOI: 10.1007/s00423-015-1289-8] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2015] [Accepted: 02/09/2015] [Indexed: 12/16/2022]
Abstract
BACKGROUND Computer-assisted surgery is a wide field of technologies with the potential to enable the surgeon to improve efficiency and efficacy of diagnosis, treatment, and clinical management. PURPOSE This review provides an overview of the most important new technologies and their applications. METHODS A MEDLINE database search was performed revealing a total of 1702 references. All references were considered for information on six main topics, namely image guidance and navigation, robot-assisted surgery, human-machine interface, surgical processes and clinical pathways, computer-assisted surgical training, and clinical decision support. Further references were obtained through cross-referencing the bibliography cited in each work. Based on their respective field of expertise, the authors chose 64 publications relevant for the purpose of this review. CONCLUSION Computer-assisted systems are increasingly used not only in experimental studies but also in clinical studies. Although computer-assisted abdominal surgery is still in its infancy, the number of studies is constantly increasing, and clinical studies start showing the benefits of computers used not only as tools of documentation and accounting but also for directly assisting surgeons during diagnosis and treatment of patients. Further developments in the field of clinical decision support even have the potential of causing a paradigm shift in how patients are diagnosed and treated.
Collapse
Affiliation(s)
- H G Kenngott
- Department of General, Abdominal and Transplant Surgery, Ruprecht-Karls-University, Heidelberg, Germany
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Hohenforst-Schmidt W, Banckwitz R, Zarogoulidis P, Vogl T, Darwiche K, Goldberg E, Huang H, Simoff M, Li Q, Browning R, Freitag L, Turner JF, Pivert PL, Yarmus L, Zarogoulidis K, Brachmann J. Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study. J Cancer 2014; 5:192-202. [PMID: 24563674 PMCID: PMC3931267 DOI: 10.7150/jca.8395] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2013] [Accepted: 01/23/2014] [Indexed: 11/18/2022] Open
Abstract
Rationale: Cone Beam Computed Tomography imaging has become increasingly important in many fields of interventional therapies. Objective: Lung navigation study which is an uncommon soft tissue approach. Methods: As no effective organ radiation dose levels were available for this kind of Cone Beam Computed Tomography application we simulated in our DynaCT (Siemens AG, Forchheim, Germany) suite 2 measurements including 3D acquisition and again for 3D acquisition and 4 endobronchial navigation maneuvers under fluoroscopy towards a nodule after the 8th segmentation in the right upper lobe over a total period of 20 minutes (min). These figures reflect the average complexity and time in our experience. We hereby describe the first time the exact protocol of lung navigation by a Cone Beam Computed Tomography approach. Measurement: The hereby first time measured body radiation doses in that approach showed very promising numbers between 0,98-1,15mSv giving specific lung radiation doses of 0,42-0,38 mSv. Main results: These figures are comparable or even better to other lung navigation systems. Cone Beam Computed Tomography offers some unique features for lung interventionists as a realtime 1-step navigation system in an open structure feasible for endobronchial and transcutaneous approach. Conclusions: Due to this low level of radiation exposure Cone Beam Computed Tomography is expected to attract interventionists interested in using and guiding endobronchial or transcutaneous ablative procedures to peripheral endobronchial and other lung lesions.
Collapse
Affiliation(s)
| | | | - Paul Zarogoulidis
- 3. Pulmonary Department-Oncology Unit, G Papanikolaou General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece; ; 4. Department of Interventional Pneumology, Ruhrlandklinik, West German Lung Center, University Hospital, University Duisburg-Essen, Essen, Germany
| | - Thomas Vogl
- 5. Department of Diagnostic and Interventional Radiology, Goethe University of Frankfurt, Frankfurt, Germany
| | - Kaid Darwiche
- 4. Department of Interventional Pneumology, Ruhrlandklinik, West German Lung Center, University Hospital, University Duisburg-Essen, Essen, Germany
| | - Eugene Goldberg
- 6. Biomaterials Science and Engineering, Department of Materials Science and Engineering, University of Florida, FL, USA
| | - Haidong Huang
- 7. Department of Respiratory Diseases, Changhai Hospital/First Affiliated Hospital of the Second Military Medical University, Shanghai, People's Republic of China; ; 8. Bronchoscopy and Interventional Pulmonology, Pulmonary and Critical Care Medicine, Henry Ford Hospital, Wayne State University, School of Medicine, MI, USA
| | - Michael Simoff
- 8. Bronchoscopy and Interventional Pulmonology, Pulmonary and Critical Care Medicine, Henry Ford Hospital, Wayne State University, School of Medicine, MI, USA
| | - Qiang Li
- 7. Department of Respiratory Diseases, Changhai Hospital/First Affiliated Hospital of the Second Military Medical University, Shanghai, People's Republic of China
| | - Robert Browning
- 9. Pulmonary and Critical Care Medicine, Interventional Pulmonology, National Naval Medical Center, Walter Reed Army Medical Center, Bethesda, MD, USA
| | - Lutz Freitag
- 4. Department of Interventional Pneumology, Ruhrlandklinik, West German Lung Center, University Hospital, University Duisburg-Essen, Essen, Germany
| | - J Francis Turner
- 10. Pulmonary Medicine, University of Nevada School of Medicine, National Supercomputing Center for Energy and the Environment University of Nevada, Las Vegas, NV, USA
| | - Patrick Le Pivert
- 11. Interventional Drug Delivery Systems and Strategies (ID2S2), Medical Cryogenics, Jupiter, FL, USA
| | - Lonny Yarmus
- 12. Division of Pulmonary and Critical Care Medicine, Sheikh Zayed Cardiovascular & Critical Care Tower, Johns Hopkins University, Baltimore, U.S.A
| | - Konstantinos Zarogoulidis
- 3. Pulmonary Department-Oncology Unit, G Papanikolaou General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Johannes Brachmann
- 1. II Medical Clinic, Coburg Hospital, University of Wuerzburg, Coburg, Germany
| |
Collapse
|
8
|
|
9
|
Real-time image guidance in laparoscopic liver surgery: first clinical experience with a guidance system based on intraoperative CT imaging. Surg Endosc 2013; 28:933-40. [PMID: 24178862 DOI: 10.1007/s00464-013-3249-0] [Citation(s) in RCA: 73] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2013] [Accepted: 10/04/2013] [Indexed: 01/11/2023]
Abstract
BACKGROUND Laparoscopic liver surgery is particularly challenging owing to restricted access, risk of bleeding, and lack of haptic feedback. Navigation systems have the potential to improve information on the exact position of intrahepatic tumors, and thus facilitate oncological resection. This study aims to evaluate the feasibility of a commercially available augmented reality (AR) guidance system employing intraoperative robotic C-arm cone-beam computed tomography (CBCT) for laparoscopic liver surgery. METHODS A human liver-like phantom with 16 target fiducials was used to evaluate the Syngo iPilot(®) AR system. Subsequently, the system was used for the laparoscopic resection of a hepatocellular carcinoma in segment 7 of a 50-year-old male patient. RESULTS In the phantom experiment, the AR system showed a mean target registration error of 0.96 ± 0.52 mm, with a maximum error of 2.49 mm. The patient successfully underwent the operation and showed no postoperative complications. CONCLUSION The use of intraoperative CBCT and AR for laparoscopic liver resection is feasible and could be considered an option for future liver surgery in complex cases.
Collapse
|
10
|
Rassweiler MC, Banckwitz R, Koehler C, Mueller-Allissat B, Michel MS, Häcker A, Ritter M. New developed urological protocols for the Uro Dyna-CT reduce radiation exposure of endourological patients below the levels of the low dose standard CT scans. World J Urol 2013; 32:1213-8. [DOI: 10.1007/s00345-013-1195-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2013] [Accepted: 10/15/2013] [Indexed: 01/10/2023] Open
|
11
|
Leßmann N, Drömann D, Schlaefer A. Feasibility of respiratory motion-compensated stereoscopic X-ray tracking for bronchoscopy. Int J Comput Assist Radiol Surg 2013; 9:199-209. [PMID: 23888315 DOI: 10.1007/s11548-013-0920-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2013] [Accepted: 07/03/2013] [Indexed: 12/01/2022]
Abstract
PURPOSE Precise localization in bronchoscopy is challenging, particularly for peripheral lesions that cannot be reached by conventional bronchoscopes with a large working channel. Existing navigation methods are hampered by respiratory motion, e.g., in the lower lobes. We present an image-guided approach that considers respiratory motion and can localize instruments. METHODS We developed a rigid chest marker containing steel balls visible in X-ray images and a pattern for passive tracking with an optical camera system. An experimental setup to evaluate stereoscopic localization and to mimic chest motion was established in our interventional suite. The marker motion was recorded, and X-ray images were acquired from different angles using a standard C-arm. All coordinates were expressed with respect to the stationary tracking camera. The feasibility of motion-compensated stereoscopic localization was assessed. RESULTS The orientation of the C-arm could be established with a mean error of less than 1°. Triangulation based on two different X-ray images from different angles resulted in a mean error of 1.8 (±0.7) mm. A similar result was obtained when the marker was moved between X-ray acquisitions, and the mean error was 1.6 (±1.4) mm. The latencies were approximately 80 and 380 ms for tracking camera and X-ray imaging, respectively. Stereoscopic localization of a moving target was feasible. CONCLUSIONS The system presents a flexible alternative for precise stereoscopic localization of a bronchoscope or instruments using a standard C-arm. We demonstrated the ability to track multiple moving markers and to compensate for respiratory motion.
Collapse
Affiliation(s)
- Nikolas Leßmann
- Medical Robotics Group, Institute for Robotics and Cognitive Systems, University of Lübeck, Lübeck, Germany
| | | | | |
Collapse
|