1
|
Jawaid S, Aboelezz AF, Daba G, Khalaf M, Ayoub F, Zabad N, Mercado M, Keihanian T, Othman M. Prospective feasibility study of a novel rigidizing stabilizing overtube in the resection of complex gastrointestinal polyps. Endoscopy 2025; 57:68-73. [PMID: 38991535 DOI: 10.1055/a-2350-4059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 07/13/2024]
Abstract
BACKGROUND A novel rigidizing overtube (ROT) was developed to facilitate endoscopic removal of complex gastrointestinal polyps. We aimed to prospectively evaluate the efficacy and safety of the device in the management of large gastrointestinal polyps. METHODS A prospective, single-center study, conducted between May 2021 and April 2023, enrolled patients undergoing endoscopic resection of colon/duodenal polyps ≥25 mm. Primary outcomes were safety, technical success, and clinical success defined as the ability of ROT to facilitate endoscopic polyp removal without changing the initial resection method. RESULTS 97 patients (98 polyps), with a mean polyp size of 33.2 mm (median 31.1), were evaluated. Technical and clinical success rates were 100% and 84%, respectively. Ileocecal valve location was the only predictor of clinical failure (P = 0.02). The mean time to reach the lesion was 7.2 minutes (95%CI 5-8), with overall resection and procedure times of 53.6 minutes (95%CI 48-61) and 88.9 minutes (95%CI 79-95), respectively. No device-related adverse events occurred. Lower technical (67%) and clinical (67%) success rates were seen for duodenal polyps (n = 6). CONCLUSION The novel ROT was safe, with high technical and clinical success during resection of complex colon polyps. Future studies will determine timing of implementation during routine endoscopic resection.
Collapse
Affiliation(s)
- Salmaan Jawaid
- Division of Gastroenterology, Hepatology and Nutrition, Baylor College of Medicine, Houston, United States
| | - Ahmed F Aboelezz
- Department of Internal Medicine, Gastroenterology and Hepatology Unit, Tanta University, Tanta, Egypt
| | - Gehad Daba
- Division of Gastroenterology, Hepatology and Nutrition, Baylor College of Medicine, Houston, United States
| | - Mai Khalaf
- Division of Gastroenterology, Hepatology and Nutrition, Baylor College of Medicine, Houston, United States
| | - Fares Ayoub
- Division of Gastroenterology, Hepatology and Nutrition, Baylor College of Medicine, Houston, United States
| | - Noor Zabad
- Division of Gastroenterology, Hepatology and Nutrition, Baylor College of Medicine, Houston, United States
| | - Michael Mercado
- Division of Gastroenterology, Hepatology and Nutrition, Baylor College of Medicine, Houston, United States
| | - Tara Keihanian
- Division of Gastroenterology, Hepatology and Nutrition, Baylor College of Medicine, Houston, United States
| | - Mohamed Othman
- Division of Gastroenterology, Hepatology and Nutrition, Baylor College of Medicine, Houston, United States
| |
Collapse
|
2
|
Aihara H, Othman MO, Jawaid SA, Gorgun E, Sharma NR, Siddiqui UD, Peetermans JA, Rousseau MJ, Nishimura M. A multicenter, retrospective study of a through-the-needle injection-capable electrosurgical knife for endoscopic submucosal dissection. Gastrointest Endosc 2024; 100:1034-1042. [PMID: 38879045 DOI: 10.1016/j.gie.2024.06.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 05/01/2024] [Accepted: 06/05/2024] [Indexed: 09/05/2024]
Abstract
BACKGROUND AND AIMS Endoscopic submucosal dissection (ESD) is a technically challenging resection technique for en bloc removal of dysplastic and early cancerous GI lesions. We conducted a single-arm retrospective study evaluating the safety and efficacy of a new through-the-needle injection-capable electrosurgical knife used in upper and lower ESD procedures performed at 6 U.S. academic centers. METHODS Data were retrospectively collected on consecutive cases in which the new ESD knife was used. The primary efficacy endpoint was successful ESD (en bloc resection with negative margins). Secondary efficacy endpoints included en bloc resection rate, curative resection rate, median ESD time, and median dissection speed. The safety endpoint was device- or procedure-related serious adverse events. RESULTS ESD procedures of 581 lesions in 579 patients were reviewed, including 187 (32.2%) upper GI and 394 (67.8%) lower GI lesions. Prior treatment was reported in 283 (48.9%) patients. Successful ESD was achieved in 477 (82.1% of 581) lesions-lower for patients with versus without submucosal fibrosis (73.6% vs 87.0%, respectively; P < .001) but similar for those with versus without previous treatment (81.7% vs 82.3%, respectively; P = .848). A total of 443 (76.2% of 581) lesions met criteria for curative resection. Median ESD time was 1.0 (range, 0.1-4.5) hour. Median dissection speed was 17.1 (interquartile range, 5.3-29.8) cm2/h. Related serious adverse events were reported in 15 (2.6%) patients, including delayed hemorrhage (1.9%), perforation (0.5%), or postpolypectomy syndrome (0.2%). CONCLUSION A newly developed through-the-needle injection-capable ESD knife showed a good success rate and excellent safety at U.S. CENTERS (Clinical trial registration number: NCT04580940.).
Collapse
Affiliation(s)
- Hiroyuki Aihara
- Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
| | - Mohamed O Othman
- Department of Gastroenterology, Baylor College of Medicine, Houston, Texas, USA
| | - Salmaan A Jawaid
- Department of Gastroenterology, Baylor College of Medicine, Houston, Texas, USA
| | - Emre Gorgun
- Department of Colorectal Surgery, Cleveland Clinic Foundation, Cleveland, Ohio, USA
| | - Neil R Sharma
- Interventional Oncology and Surgical Endoscopy Program, Gastro Care Partners, Denver, Colorado USA; Peak Gastroenterology Associates, Denver, Colorado, USA
| | - Uzma D Siddiqui
- University of Chicago, Center for Endoscopic Research and Therapeutics, Chicago, Illinois, Chicago, USA
| | - Joyce A Peetermans
- Endoscopy Division, Boston Scientific Corporation, Marlborough, Massachusetts, USA
| | - Matthew J Rousseau
- Endoscopy Division, Boston Scientific Corporation, Marlborough, Massachusetts, USA
| | - Makoto Nishimura
- Department of Gastroenterology, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| |
Collapse
|
3
|
Wei MT, Hwang JH, Watson RR, Park W, Friedland S. Novel rigidizing overtube for colonoscope stabilization and loop prevention (with video). Gastrointest Endosc 2021; 93:740-749. [PMID: 32739483 DOI: 10.1016/j.gie.2020.07.054] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Accepted: 07/24/2020] [Indexed: 12/11/2022]
Abstract
BACKGROUND AND AIMS Loop formation can impede endoscope advancement, destabilize the tip, and cause pain. Strategies to mitigate looping include torque-based reduction maneuvers, variable stiffness shafts, and abdominal splinting. In some cases, these strategies are insufficient, and there is need for novel instruments. Loop formation is of particular concern in colonoscopy, but it can also impact performance of other endoscopic procedures such as enteroscopy and altered-anatomy ERCP. In this case series we demonstrate the utility of a novel rigidizing overtube (Pathfinder; Neptune Medical, Burlingame, Calif, USA) in colonoscopy and other endoscopic procedures where loop management is critical. METHODS We describe our initial experience with the Pathfinder overtube in 29 patients. The overtube is 85 cm long and can accommodate a pediatric colonoscope. In its native state, the overtube is extremely flexible. Once the overtube is advanced to the desired location, application of a vacuum to the device causes the device to become 15 times stiffer. The endoscope can then be advanced through the overtube without loop formation in the region that the overtube traverses. RESULTS The overtube was used in 29 patients to assist with difficult procedures. Patients were predominantly men (n = 18; 62.1%), with a median age of 66 years (interquartile range, 57-72). One patient received an upper endoscopy (3.4%), 24 received colonoscopy (82.8%), and 4 received enteroscopy (13.8%). The overtube was used in 12 procedures for incomplete colonoscopy (41.4%), 6 for depth (20.7%), and 11 for stability (37.9%). Colonoscopy was performed in the setting of screening (n = 3), surveillance given polyp history (n = 7), referrals for polyp removal (n = 10), workup of iron deficiency anemia (n = 2), and incomplete colonoscopy (n = 1). The lower endoscopy cases had a median cecal intubation time of 5 minutes (interquartile range, 4.25-7). Enteroscopy was performed in 4 patients: In one patient the distal 60 cm of the ileum was examined with a pediatric colonoscope to exclude ileitis, in another the overtube was used to stabilize a 6-mm endoscope to traverse a tight Crohn's ileocolonic stricture, in a third patient altered-anatomy ERCP was performed using an enteroscope through the overtube to reach a hepaticojejunostomy, and in the final patient upper enteroscopy was performed and the mid-jejunum was reached. We present 4 cases that demonstrate the use of the overtube. There were no adverse events. CONCLUSIONS Initial experience with a novel rigidizing overtube suggests that this tool can be useful in colonoscopy and other endoscopic procedures affected by looping.
Collapse
Affiliation(s)
- Mike Tzuhen Wei
- Division of Gastroenterology and Hepatology, Department of Medicine, Stanford University School of Medicine, Stanford, California, USA; Department of Gastroenterology and Hepatology, Veterans Affairs Palo Alto Health Care System, Palo Alto, California, USA
| | - Joo Ha Hwang
- Division of Gastroenterology and Hepatology, Department of Medicine, Stanford University School of Medicine, Stanford, California, USA
| | - Rabindra R Watson
- Interventional Endoscopy Services, California Pacific Medical Center, San Francisco, California, USA
| | - Walter Park
- Division of Gastroenterology and Hepatology, Department of Medicine, Stanford University School of Medicine, Stanford, California, USA
| | - Shai Friedland
- Division of Gastroenterology and Hepatology, Department of Medicine, Stanford University School of Medicine, Stanford, California, USA; Department of Gastroenterology and Hepatology, Veterans Affairs Palo Alto Health Care System, Palo Alto, California, USA
| |
Collapse
|
4
|
Yang D, Draganov PV. Expanding Role of Third Space Endoscopy in the Management of Esophageal Diseases. ACTA ACUST UNITED AC 2018; 16:41-57. [PMID: 29435819 DOI: 10.1007/s11938-018-0169-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
OPINION STATEMENT: "Third space" endoscopy, also commonly referred as submucosal endoscopy, is founded on the principle that the deeper layers of the gastrointestinal (GI) tract can be accessed by tunneling in the submucosal space without compromising the integrity of the overlying mucosa. Peroral endoscopic myotomy (POEM), endoscopic submucosal dissection (ESD), and submucosal tunneling endoscopic resection (STER) are innovative techniques within the field of third space endoscopy in the management of esophageal disorders. POEM has become an accepted minimally invasive therapy for achalasia and related motility disorders with excellent short-term results, with early studies yielding similar efficacy to surgical myotomy and increased durability when compared to pneumatic balloon dilation (PBD). Data are needed to establish long-term outcomes with POEM, with particular interest on the incidence of gastroesophageal reflux, which appears to be higher than initially anticipated. ESD, a mature endoscopic resection technique in Asia, has recently gained traction in the West as a viable option for the management of early Barrett's esophagus (BE) neoplasia. Compared to standard endoscopic mucosal resection (EMR), ESD allows the en bloc resection of lesions irrespective of size, which may facilitate histological interpretation and reduce recurrence rates. Large prospective randomized controlled trials are needed to validate the efficacy and safety of this technique and to further define its role in the endoscopic armamentarium in early BE neoplasia. STER is an attractive technique that theoretically permits the resection of subepithelial esophageal tumors (SETs) arising from the deeper GI layers. Initial studies from highly experienced endoscopic centers support its technical feasibility and safety, although these results should be interpreted with caution due to variability arising from small numbers and heterogeneity among studies. Overall, third space endoscopy is an expanding field within endoscopic therapeutics for the treatment of esophageal diseases. While initial results have been very promising, large prospective studies, long-term data, and structured training programs with the establishment of competency parameters are needed before third space endoscopy can be advocated outside of highly specialized centers.
Collapse
Affiliation(s)
- Dennis Yang
- Division of Gastroenterology, Hepatology and Nutrition, University of Florida, 1329 SW 16th Street Suite 5262, Gainesville, FL, 32608, USA
| | - Peter V Draganov
- Division of Gastroenterology, Hepatology and Nutrition, University of Florida, 1329 SW 16th Street Suite 5262, Gainesville, FL, 32608, USA.
| |
Collapse
|