1
|
Razzaz D, Linder S, Waldthaler A, Holmberg M, Ghorbani P. Predictive factors for long-term patency in duodenal stenting for malignant gastric outlet obstruction. Endosc Int Open 2025; 13:a24872722. [PMID: 39958665 PMCID: PMC11827748 DOI: 10.1055/a-2487-2722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2024] [Accepted: 10/25/2024] [Indexed: 02/18/2025] Open
Abstract
Background and study aims Malignant gastric outlet obstruction (GOO) occurs often late during disseminated disease, requiring palliation. Placement of duodenal self-expandable metal stents (SEMS) is a common method for relieving malignant GOO but recurrent obstruction is common, warranting reintervention. The aim of the present study was to identify predictive factors for stent patency at 3 months and survival. Also, stent patency rate and adverse events after duodenal stenting were analyzed. Patients and methods This was a retrospective observational single-center study including all patients with malignant GOO receiving duodenal SEMS for palliation (2008-2021). Logistic regression for stent patency (3 months) and Cox regression for survival were undertaken. Results Overall, 198 patients were included. The most common malignancies were pancreatic adenocarcinoma (40%), gastric adenocarcinoma (18%), and cholangiocarcinoma (13%). Uncovered SEMS were used in 88% of patients and the reintervention rate was 44%. The stent patency rate was 63% in 188 patients with clinical success. Predictors of stent patency at 3 months were jaundice, semi- or fully-covered stents, and chemotherapy prior to stenting. Median survival was 81 days (interquartile range 40-241) after stenting. In Cox regression, predictors for overall survival at 6 months were absence of jaundice and stent patency at 3 months. Stent dysfunction was the most common cause of reintervention and was managed by repeated stent (76%) or dilation (11%). Conclusions Treatment of malignant GOO with duodenal SEMS is effective but the reintervention rate is high. Predictors of stent patency were jaundice, semi- or fully-covered SEMS, and chemotherapy. Survival was impaired by jaundice and stent dysfunction.
Collapse
Affiliation(s)
- David Razzaz
- Surgery and Oncology, Capio St Gorans Hospital, Stockholm, Sweden
| | - Stefan Linder
- Department of Clinical Science Intervention and Technology, Karolinska Institute, Stockholm, Sweden
| | | | - Marcus Holmberg
- Surgery and Oncology, Capio St Gorans Hospital, Stockholm, Sweden
| | - Poya Ghorbani
- Department of Clinical Science Intervention and Technology, Karolinska Institute, Stockholm, Sweden
| |
Collapse
|
2
|
Lim SG, Kim CG. Endoscopic stenting for malignant gastric outlet obstruction: focusing on comparison of endoscopic stenting and surgical gastrojejunostomy. Clin Endosc 2024; 57:571-580. [PMID: 38389304 PMCID: PMC11474473 DOI: 10.5946/ce.2023.160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 09/10/2023] [Accepted: 09/11/2023] [Indexed: 02/24/2024] Open
Abstract
Malignant gastric outlet obstruction (GOO) is a condition characterized by blockage or narrowing where the stomach empties its contents into the small intestine due to primary malignant tumors or metastatic diseases. This condition leads to various symptoms such as nausea, vomiting, abdominal pain, and weight loss. To manage malignant GOO, different treatment options have been employed, including surgical gastrojejunostomy (SGJ), gastroduodenal stenting (GDS) using self-expandable metallic stent (SEMS), and endoscopic ultrasound-guided gastrojejunostomy (EUS-GJ). This review focuses on comparing the clinical outcomes of endoscopic stenting (GDS and EUS-GJ) with SGJ for malignant GOO. Studies have shown that GDS with SEMS provides comparable clinical outcomes and safety for the palliation of obstructive symptoms. The choice between covered and uncovered SEMS remains controversial, as different studies have reported varying results. EUS-GJ, performed via endoscopic ultrasound guidance, has shown promising efficacy and safety in managing malignant GOO, but further studies are needed to establish it as the primary treatment option. Comparative analyses suggest that GDS has higher recurrence and reintervention rates compared to EUS-GJ and SGJ, with similar overall procedural complications. However, bleeding rates were lower with GDS than with SGJ. Randomized controlled trials are required to determine the optimal treatment approach for malignant GOO.
Collapse
Affiliation(s)
- Sun Gyo Lim
- Department of Gastroenterology, Ajou University School of Medicine, Suwon, Korea
| | - Chan Gyoo Kim
- Center for Gastric Cancer, National Cancer Center, Goyang, Korea
| |
Collapse
|
3
|
Su HJ, Chen CC, Kuo YT, Han ML, Tsai MC, Liu KL, Wang HP. Clinical outcomes of different types of metallic stents in malignant distal duodenum stenosis: A retrospective study. J Formos Med Assoc 2024; 123:854-859. [PMID: 38171957 DOI: 10.1016/j.jfma.2023.12.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2023] [Revised: 12/06/2023] [Accepted: 12/20/2023] [Indexed: 01/05/2024] Open
Abstract
BACKGROUND/PURPOSE Endoscopic stenting at malignant distal duodenum stenosis (MDDS) is challenging because of the duodenal C-loop configuration, the acute angle of the duodenojejunal junction, and the limited length of the endoscope. Few studies have investigated the clinical outcomes of stenting at the distal duodenum. Therefore, this study aimed to investigate the clinical outcomes of treating MDDS with different types of metallic stents. METHODS From January 2012 to December 2020, fifty-six patients with MDDS who underwent duodenal stenting were enrolled for analysis. Thirty-five patients received uncovered self-expandable metallic stents (UC-SEMS), and twenty-one patients received partially covered self-expandable metallic stents (PC-SEMS). All patients were followed up till death or for 18 months. The clinical success rate, stent dysfunction rate, and stent patency were compared between the groups. Multivariate analysis was conducted to identify factors related to stent dysfunction. RESULTS The clinical success rates were 85.7 % in both the UC-SEMS and PC-SEMS groups. Stent dysfunction rates (UC-SEMS: 34.3 %, PC-SEMS: 38.1 %, p = 0.773) and the average stent patency (UC-SEMS: 117.2 days, PC-SEMS: 100.0 days, p = 0.576) were not statistically different between the groups. Multivariate analysis disclosed the age ≥65 years was significantly related to stent dysfunction (odds ratio: 4.78, p = 0.031). CONCLUSION Both UC-SEMS and PC-SEMS are safe and effective treatment options for MDDS. However, stent dysfunction remains a significant issue to overcome, particularly in the elderly. Further research is needed to explore novel strategies that can improve the effectiveness of stent placement and reduce the risk of stent dysfunction.
Collapse
Affiliation(s)
- Hau-Jyun Su
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan; Division of Gastroenterology and Hepatology, Department of Internal Medicine, Chung Shan Medical University Hospital, Taichung, Taiwan; School of Medicine, Chung Shan Medical University, Taichung, Taiwan
| | - Chieh-Chang Chen
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan; Department of Internal Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan; Graduate Institute of Clinical Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan
| | - Yu-Ting Kuo
- Department of Internal Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan; Division of Endoscopy, Department of Integrated Diagnostics and Therapeutics, National Taiwan University Hospital, Taipei, Taiwan
| | - Ming-Lun Han
- Department of Internal Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan; Division of Endoscopy, Department of Integrated Diagnostics and Therapeutics, National Taiwan University Hospital, Taipei, Taiwan
| | - Ming-Chang Tsai
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Chung Shan Medical University Hospital, Taichung, Taiwan; School of Medicine, Chung Shan Medical University, Taichung, Taiwan
| | - Kao-Lang Liu
- Department of Medical Imaging, National Taiwan University Cancer Center, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei, Taiwan
| | - Hsiu-Po Wang
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan; Department of Internal Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan.
| |
Collapse
|
4
|
Tamura T, Shimokawa T, Yamashita Y, Yamao K, Kitano M. Uncovered versus covered expandable metal stents for malignant gastric outlet obstruction caused by intrinsic and extrinsic tumors: meta-analysis and meta-regression analysis. Surg Endosc 2022; 37:2496-2507. [PMID: 36513783 DOI: 10.1007/s00464-022-09774-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Accepted: 11/22/2022] [Indexed: 12/15/2022]
Abstract
BACKGROUND AND AIMS Malignant gastric outlet obstruction (GOO) can be palliated by endoscopic placement of self-expandable metal stents (SEMSs). Studies comparing uncovered (USEMSs) and covered (CSEMSs) SEMSs have yielded inconclusive results. This meta-analysis compared USEMSs with CSEMSs in patients with GOO caused by intrinsic and extrinsic tumors. METHODS Potentially relevant articles were identified by searching PubMed, the Cochrane Library, and Medline. The primary outcome was stent dysfunction. Relationships between characteristics of tumors causing GOO and the stent dysfunction rate following USEMSs and CSEMS placement were assessed. RESULTS Overall, six randomized controlled trials and 12 observational studies, including 2431 patients, were identified. Rate of stent dysfunction did not differ significantly between USEMSs and CSEMSs (odds ratio [OR], 0.95; 95% confidence interval [CI], 0.73-1.25, I2 = 44%), but there was heterogeneity. Meta-regression analysis showed that heterogeneity of stent dysfunction was caused by a difference in the ratio of intrinsic-to-extrinsic tumors causing GOO between studies (coefficient, 0.944; 95% CI, 0.30-1.58). Studies were divided into intrinsic and extrinsic tumor groups. Subgroup analysis showed that the stent dysfunction rate did not differ between USEMSs and CSEMSs in the intrinsic tumor group (OR, 1.10; 95% CI, 0.85-1.41; I2 = 32%). In the extrinsic tumor group, USEMS was associated with a lower rate of stent dysfunction than CSEMS (OR, 0.64; 95% CI, 0.47-0.87; I2 = 25%). CONCLUSION USEMS and CSEMS placement generally showed comparable outcomes among patients with GOO. USEMS was more effective than CSEMS for patients with GOO caused by extrinsic tumors.
Collapse
Affiliation(s)
- Takashi Tamura
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-8509, Japan
| | - Toshio Shimokawa
- Clinical Study Support Center, Wakayama Medical University Hospital, Wakayama, Japan
| | - Yasunobu Yamashita
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-8509, Japan
| | - Kentaro Yamao
- Department of Gastroenterology and Hepatology, Faculty of Medicine, Kindai University, Osaka, Japan
| | - Masayuki Kitano
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-8509, Japan.
| |
Collapse
|
5
|
Takamatsu Y, Fujimori N, Miyagahara T, Suehiro Y, Kaku T, Kawabe K, Ohno A, Matsumoto K, Murakami M, Teramatsu K, Takeno A, Oono T, Ogawa Y. The Glasgow Prognostic Score and stricture site can predict prognosis after endoscopic duodenal stent placement for malignant gastric outlet obstruction. Sci Rep 2022; 12:9746. [PMID: 35697819 PMCID: PMC9192609 DOI: 10.1038/s41598-022-13209-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2021] [Accepted: 05/23/2022] [Indexed: 11/24/2022] Open
Abstract
Endoscopic duodenal stent (DS) placement for malignant gastric outlet obstruction (GOO) is rapidly increasing in clinical practice; however, the most suitable patient candidates for DS placement have not been determined. One hundred and thirty-five patients with GOO who underwent DS placement in three Japanese referral centers between January 2010 and October 2019 were retrospectively evaluated. Overall survival (OS) after DS placement, technical/clinical success rates, adverse events, and predictive factors affecting OS after DS placement were also analyzed. The median OS after DS placement of all patients was 81 (7–901) days. Technical and clinical success rates were 99.3% and 83.7%, respectively. The GOO Scoring System score significantly increased before and after DS placement (0.9 vs. 2.7, P < 0.001). The procedure-related complication rate was 6.0%. All 19 patients (14.1%) with stent occlusion underwent endoscopic re-intervention successfully. Multivariate analyses revealed chemotherapy after DS placement (P = 0.01), stricture site in D3 (distal part of the papilla) (P = 0.01), and a Glasgow Prognostic Score (GPS) of 0–1 before duodenal stent placement (P < 0.001) were factors significantly associated with prolonged OS. In conclusion, patients with a GPS of 0–1 and D3 stricture who are tolerant of chemotherapy are suitable candidates for DS placement.
Collapse
Affiliation(s)
- Yu Takamatsu
- Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Nao Fujimori
- Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
| | - Tsukasa Miyagahara
- Department of Gastroenterology, Nakatsu Municipal Hospital, Nakatsu, Japan
| | - Yuta Suehiro
- Department of Gastroenterology, Nakatsu Municipal Hospital, Nakatsu, Japan
| | - Toyoma Kaku
- Department of Gastroenterology, Clinical Research Institute, National Hospital Organization Kyushu Medical Center, Fukuoka, Japan
| | - Ken Kawabe
- Department of Gastroenterology, Clinical Research Institute, National Hospital Organization Kyushu Medical Center, Fukuoka, Japan
| | - Akihisa Ohno
- Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Kazuhide Matsumoto
- Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Masatoshi Murakami
- Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Katsuhito Teramatsu
- Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Ayumu Takeno
- Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Takamasa Oono
- Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Yoshihiro Ogawa
- Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| |
Collapse
|
6
|
Krishnamoorthi R, Bomman S, Benias P, Kozarek RA, Peetermans JA, McMullen E, Gjata O, Irani SS. Efficacy and safety of endoscopic duodenal stent versus endoscopic or surgical gastrojejunostomy to treat malignant gastric outlet obstruction: systematic review and meta-analysis. Endosc Int Open 2022; 10:E874-E897. [PMID: 35692924 PMCID: PMC9187371 DOI: 10.1055/a-1794-0635] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 01/13/2022] [Indexed: 11/28/2022] Open
Abstract
Background and study aims Malignant disease accounts for up to 80 % of gastric outlet obstruction (GOO) cases, which may be treated with duodenal self-expanding metal stents (SEMS), surgical gastrojejunostomy (GJ), and more recently endoscopic-ultrasound-guided gastroenterostomy (EUS-GE). These three treatments have not been compared head-to-head in a randomized trial. Methods We searched the Embase and MEDLINE databases for studies published January 2015-February 2021 assessing treatment of malignant GOO using duodenal SEMS, endoscopic (EUS-GE) or surgical (laparoscopic or open) GJ. Efficacy outcomes assessed included technical and clinical success rates, GOO recurrence and reintervention. Safety outcomes included procedure-related bleeding or perforation, and stent-related events for the duodenal SEMS and EUS-GE arms. Results EUS-GE had a lower rate of technical success (95.3%) than duodenal SEMS (99.4 %) or surgical GJ (99.9%) ( P = 0.0048). For duodenal SEMS vs. EUS-GE vs. surgical GJ, rates of clinical success (88.9 % vs. 89.0 % vs. 92.3 % respectively, P = 0.49) were similar. EUS-GE had a lower rate of GOO recurrence based on limited data ( P = 0.0036), while duodenal SEMS had a higher rate of reintervention ( P = 0.041). Overall procedural complications were similar (duodenal SEMS 18.7 % vs. EUS-GE 21.9 % vs. surgical GJ 23.8 %, P = 0.32), but estimated bleeding rate was lowest ( P = 0.0048) and stent occlusion rate was highest ( P = 0.0002) for duodenal SEMS. Conclusions Duodenal SEMS, EUS-GE, and surgical GJ showed similar clinical efficacy for the treatment of malignant GOO. Duodenal SEMS had a lower procedure-related bleeding rate but higher rate of reintervention.
Collapse
Affiliation(s)
- Rajesh Krishnamoorthi
- Department of Gastroenterology and Hepatology, Virginia Mason Medical Center, Seattle, Washington, United States
| | - Shivanand Bomman
- Department of Gastroenterology and Hepatology, Virginia Mason Medical Center, Seattle, Washington, United States
| | - Petros Benias
- Division of Gastroenterology, Zucker School of Medicine at Hofstra/Northwell, North Shore University Hospital, Manhasset, New York, United States
| | - Richard A. Kozarek
- Department of Gastroenterology and Hepatology, Virginia Mason Medical Center, Seattle, Washington, United States
| | - Joyce A. Peetermans
- Endoscopy Division, Boston Scientific Corporation, Marlborough, Massachusetts, United States
| | - Edmund McMullen
- Endoscopy Division, Boston Scientific Corporation, Marlborough, Massachusetts, United States
| | - Ornela Gjata
- Endoscopy Division, Boston Scientific Corporation, Marlborough, Massachusetts, United States
| | - Shayan S. Irani
- Department of Gastroenterology and Hepatology, Virginia Mason Medical Center, Seattle, Washington, United States
| |
Collapse
|
7
|
Campana LG, Fish R, Dickinson OT, McNamara MG, O'Dwyer ST, Laasch HU. Distal migration of a partially covered duodenal stent requiring emergency surgical extraction. INTERNATIONAL JOURNAL OF GASTROINTESTINAL INTERVENTION 2022. [DOI: 10.18528/ijgii210044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Affiliation(s)
- Luca Giovanni Campana
- Department of Surgery, Colorectal and Peritoneal Oncology Centre (CPOC), The Christie NHS Foundation Trust, Manchester, UK
| | - Rebecca Fish
- Department of Surgery, Colorectal and Peritoneal Oncology Centre (CPOC), The Christie NHS Foundation Trust, Manchester, UK
| | | | - Mairéad Geraldine McNamara
- Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
- Department of Medical Oncology, The Christie NHS Foundation Trust, Manchester, UK
| | - Sarah Theresa O'Dwyer
- Department of Surgery, Colorectal and Peritoneal Oncology Centre (CPOC), The Christie NHS Foundation Trust, Manchester, UK
- Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| | - Hans-Ulrich Laasch
- Department of Radiology, The Christie NHS Foundation Trust, Manchester, UK
- Minnova Medical Foundation CIC, Wilmslow, UK
| |
Collapse
|
8
|
Wang C, Niu H, Yang C, Liu J, Wang Y, Ju S, Bai Y, Ren J, Xiong B. Covered vs. uncovered self-expandable metal stents for palliation of malignant afferent loop obstruction: a multicenter study. Scand J Gastroenterol 2022; 57:364-370. [PMID: 34842020 DOI: 10.1080/00365521.2021.2009023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND AND AIMS Endoscopic stent placement is a palliative therapy for malignant digestive tract obstruction. However, its use for malignant afferent loop obstruction (mALO) has not been adequately investigated. METHODS From March 2009 to December 2020, 137 patients with mALO who underwent endoscopic stent placement at three tertiary care centers were retrospectively enrolled. The primary aim of this study was to compare stent dysfunction (SD) between the covered self-expandable metal stent (CSEMS) and uncovered self-expandable metal stent (UCSEMS) groups, with subgroup analysis among patients with extrinsic and intrinsic tumors separately. RESULTS Twenty-three patients developed SD in the CSEMS group and 29 patients in the UCSEMS group (log-rank p = .974). The primary contributors to SD included a higher risk of stent migration in the CSEMS group and stent ingrowth in the UCSEMS group (p = .003; p < .001). Among patients with extrinsic tumors, the CSEMS group showed a significantly higher probability of overall SD (p = .008) and stent migration (p = .001) with a shorter time to SD (log-rank p = .006) than the UCSEMS group. Among patients with intrinsic tumors, the CSEMS group showed a significantly lower incidence of overall SD (p < .001) and stent ingrowth (p < .001) with a longer time to SD (log-rank p = .011) than the UCSEMS group. CONCLUSIONS Our results showed no significant difference in SD between the CSEMS and UCSEMS groups for palliation of mALO. Furthermore, subgroup analysis suggested using CSEMSs for patients with intrinsic tumors, and UCSEMSs for those with extrinsic tumors.
Collapse
Affiliation(s)
- Chaoyang Wang
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Huanzhang Niu
- Department of Interventional Radiology, The First Affiliated Hospital, Henan University of Science and Technology, Luoyang, China
| | - Chongtu Yang
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Jiacheng Liu
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Yingliang Wang
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Shuguang Ju
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Yaowei Bai
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Jianzhuang Ren
- Department of Interventional Radiology, The First Affiliated Hospital, Zhengzhou University, Zhengzhou, China
| | - Bin Xiong
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| |
Collapse
|
9
|
Hori Y, Hayashi K, Naitoh I, Miyabe K, Natsume M, Yoshida M, Kataoka H. A pilot study of novel duodenal covered self-expandable metal stent fixation. Sci Rep 2021; 11:19708. [PMID: 34611264 PMCID: PMC8492690 DOI: 10.1038/s41598-021-99265-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Accepted: 09/22/2021] [Indexed: 11/30/2022] Open
Abstract
Migration of duodenal covered self-expandable metal stents (C-SEMSs) is the main cause of stent dysfunction in patients with malignant gastric outlet obstruction (mGOO). Because endoscopic SEMS placement is frequently selected in patients with poor performance status, we concurrently focused on the safety of the treatment. This pilot study included 15 consecutive patients with mGOO who underwent duodenal partially covered SEMS (PC-SEMS) placement with fixation using an over-the-scope-clip (OTSC). Technical feasibility, clinical success for oral intake estimated by the Gastric Outlet Obstruction Scoring System (GOOSS) score, and adverse events including stent migration were retrospectively assessed. All procedures were successful, and clinical success was achieved in 86.7% (13/15). Mean GOOSS scores were improved from 0.07 to 2.53 after the procedure (P < 0.001). Median survival time was 84 days, and all patients were followed up until death. Stent migration occurred in one case (6.7%) at day 17, which was successfully treated by removal of the migrated PC-SEMS using an enteroscope. For fixation using an OTSC, additional time required for the procedure was 8.9 ± 4.1 min and we did not observe OTSC-associated adverse events. Poor performance status was associated with clinical success (P = 0.03), but we could provide the treatment safely and reduce mGOO symptoms even in patients with poor performance status. In conclusion, duodenal PC-SEMS fixation using an OTSC is feasible for preventing stent migration in patients with mGOO including those with poor performance status.
Collapse
Affiliation(s)
- Yasuki Hori
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan.
| | - Kazuki Hayashi
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan
| | - Itaru Naitoh
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan
| | - Katsuyuki Miyabe
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan
| | - Makoto Natsume
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan
| | - Michihiro Yoshida
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan
| | - Hiromi Kataoka
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan
| |
Collapse
|
10
|
Yamao K, Kitano M, Chiba Y, Ogura T, Eguchi T, Moriyama I, Yamashita Y, Kato H, Kayahara T, Hoki N, Okabe Y, Shiomi H, Nakai Y, Kushiyama Y, Fujimoto Y, Hayashi S, Bamba S, Kudo Y, Azemoto N, Ueki T, Uza N, Asada M, Matsumoto K, Nebiki H, Takihara H, Noguchi C, Kamada H, Nakase K, Goto D, Sanuki T, Koga T, Hashimoto S, Nishikiori H, Serikawa M, Hanada K, Hirao K, Ohana M, Kazuyuki I, Kato T, Yoshida M, Kawamoto H. Endoscopic placement of covered versus uncovered self-expandable metal stents for palliation of malignant gastric outlet obstruction. Gut 2021; 70:1244-1252. [PMID: 33223499 PMCID: PMC8223634 DOI: 10.1136/gutjnl-2020-320775] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 10/27/2020] [Accepted: 10/29/2020] [Indexed: 12/12/2022]
Abstract
OBJECTIVE Stenting is an established endoscopic therapy for malignant gastric outlet obstruction (mGOO). The choice of stent (covered vs uncovered) has been examined in prior randomised studies without clear results. DESIGN In a multicentre randomised prospective study, we compared covered (CSEMS) with uncovered self-expandable metal stents (UCSEMS) in patients with mGOO; main outcomes were stent dysfunction and patient survival, with subgroup analyses of patients with extrinsic and intrinsic tumours. RESULTS Overall survival was poor with no difference between groups (probability at 3 months 49.7% for covered vs 48.4% for uncovered stents; log-rank for overall survival p=0.26). Within that setting of short survival, the proportion of stent dysfunction was significantly higher for uncovered stents (35.2% vs 23.4%, p=0.01) with significantly shorter time to stent dysfunction. This was mainly relevant for patients with extrinsic tumours (stent dysfunction rates for uncovered stents 35.6% vs 17.5%, p<0.01). Subgrouping was also relevant with respect to tumour ingrowth (lower with covered stents for intrinsic tumours; 1.6% vs 27.7%, p<0.01) and stent migration (higher with covered stents for extrinsic tumours: 15.3% vs 2.5%, p<0.01). CONCLUSIONS Due to poor patient survival, minor differences between covered and uncovered stents may be less relevant even if statistically significant; however, subgroup analysis would suggest to use covered stents for intrinsic and uncovered stents for extrinsic malignancies.
Collapse
Affiliation(s)
- Kentaro Yamao
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine Hospital, Osakasayama, Osaka, Japan
| | - Masayuki Kitano
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine Hospital, Osakasayama, Osaka, Japan .,Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Wakayama, Japan
| | - Yasutaka Chiba
- Clinical Research Center, Kindai University Hospital, Osaka-sayama, Japan
| | - Takeshi Ogura
- Second Department of Internal Medicine, Osaka Medical College, Takatsuki, Osaka, Japan
| | - Takaaki Eguchi
- Gastroenterology and Hepatology, Osaka Saiseikai Nakatsu Hospital, Osaka, Japan
| | - Ichiro Moriyama
- Innovative Cancer Center, Shimane University Hospital, Matsue, Shimane, Japan
| | - Yukitaka Yamashita
- Department of Gastroenterology and Hepatology, Japanese Red Cross Wakayama Medical Center, Wakayama, Japan
| | - Hironari Kato
- Department of Gastroenterology and Hepatology, Okayama University, Okayama, Japan
| | - Takahisa Kayahara
- Department of Gastroenterology and Hepatology, Kurashiki Central Hospital, Kurashiki, Japan
| | - Noriyuki Hoki
- Gastroenterology, Bell Land General Hospital, Sakai, Japan
| | - Yoshinobu Okabe
- Division of Gastroenterology, Department of Medicine, Kurume University, Kurume, Japan
| | - Hideyuki Shiomi
- Division of Gastroenterology, Department of Internal Medicine, Kobe University, Kobe, Hyogo, Japan
| | - Yoshitaka Nakai
- Digestive Disease Center, Department of Gastroenterology and Hepatology, Kyoto Katsura Hospital, Kyoto, Japan
| | | | - Yoshifumi Fujimoto
- Department of Gastroenterology and Hepatology, JA Hiroshima Koseiren Hiroshima General Hospital, Hatsukaichi, Hiroshima, Japan
| | - Shiro Hayashi
- Department of Gastroenterology and Hepatology, Toyonaka Municipal Hospital, Toyonaka, Osaka, Japan
| | - Shigeki Bamba
- Division of Clinical Nutrition, Shiga University of Medical Science, Otsu, Japan
| | - Yasushi Kudo
- Digestive Disease Center, The Tazuke Kofukai Medical Research Institute, Kitano Hospital, Osaka, Japan
| | - Nobuaki Azemoto
- Department of Gastroenterology, Shikoku Cancer Center, Matuyama, Japan
| | - Toshiharu Ueki
- Department of Gastroenterology, Fukuoka University Chikushi Hospital, Chikushino, Japan
| | - Norimitsu Uza
- Department of Gastroenterology and Hepatology, Kyoto University, Kyoto, Japan
| | - Masanori Asada
- Department of Gastroenterology and Hepatology, Japanese Red Cross Society Osaka Hospital, Osaka, Osaka, Japan
| | - Kazuya Matsumoto
- Division of Medicine and Clinical Science, Tottori University, Yonago, Japan
| | - Hiroko Nebiki
- Department of Gastroenterology, Osaka City General Hospital, Osaka, Japan
| | - Hiroshi Takihara
- Department of Gastroenterology and Hepatology, Kishiwada Tokushukai Hospital, Kishiwada, Japan
| | - Chisio Noguchi
- Department of Gastroenterology, Shinbeppu Hospital, Beppu, Japan
| | - Hideki Kamada
- Gastroenterology and Neurology, Kagawa University, Kagawa, Japan
| | - Kojiro Nakase
- Department of Gastroenterology, Japanese Red Cross Kyoto Daini Hospital, Kyoto, Japan
| | - Daisuke Goto
- Department of Gastroenterology and Hepatology, Tottori Municipal Hospital, Tottori, Japan,Department of Gastroenterology and Hepatology, Tottori Red Cross Hospital, Tottori, Japan
| | - Tsuyoshi Sanuki
- Department of Gastroenterology, Kitaharima Medical Center, Ono, Japan
| | - Tetsuya Koga
- Department of Gastroenterology, Social Media Corporation Tenyoukai Central Hospital, Kagoshima, Japan
| | - Shinichi Hashimoto
- Digestive and Life-style Diseases, Kagoshima University Graduate School of Medicine and Dental Sciences, Kagoshima, Kagoshima, Japan
| | | | - Masahiro Serikawa
- Department of Gastroenterology and Metabolism, Hiroshima University Hospital, Hiroshima, Japan
| | - Keiji Hanada
- Department of Gastroenterology, Onomichi General Hospital, Onomichi, Hiroshima, Japan
| | - Ken Hirao
- Department of Internal Medicine, Hiroshima City Hiroshima Citizens Hospital, Hiroshima, Hiroshima, Japan
| | - Masaya Ohana
- Department of Gastroenterology, Tenri Hospital, Tenri, Nara, Japan
| | - Imakiire Kazuyuki
- Department of Gastroenterology, Imakiire General Hospital, Kagoshima, Japan
| | - Takao Kato
- Department of Gastroenterology, Hyogo Prefectural Awaji Medical Center, Sumoto, Japan
| | - Motoyuki Yoshida
- Third department of Internal Medicine, Nara Medical University, Kashihara, Nara, Japan
| | | |
Collapse
|
11
|
Jue TL, Storm AC, Naveed M, Fishman DS, Qumseya BJ, McRee AJ, Truty MJ, Khashab MA, Agrawal D, Al-Haddad M, Amateau SK, Buxbaum JL, Calderwood AH, DeWitt J, DiMaio CJ, Fujii-Lau LL, Gurudu SR, Jamil LH, Kwon RS, Law JK, Lee JK, Pawa S, Sawhney MS, Thosani NC, Yang J, Wani SB. ASGE guideline on the role of endoscopy in the management of benign and malignant gastroduodenal obstruction. Gastrointest Endosc 2021; 93:309-322.e4. [PMID: 33168194 DOI: 10.1016/j.gie.2020.07.063] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Accepted: 07/31/2020] [Indexed: 02/08/2023]
Abstract
This American Society for Gastrointestinal Endoscopy guideline provides evidence-based recommendations for the endoscopic management of gastric outlet obstruction (GOO). We applied the Grading of Recommendations, Assessment, Development and Evaluation methodology to address key clinical questions. These include the comparison of (1) surgical gastrojejunostomy to the placement of self-expandable metallic stents (SEMS) for malignant GOO, (2) covered versus uncovered SEMS for malignant GOO, and (3) endoscopic and surgical interventions for the management of benign GOO. Recommendations provided in this document were founded on the certainty of the evidence, balance of benefits and harms, considerations of patient and caregiver preferences, resource utilization, and cost-effectiveness.
Collapse
Affiliation(s)
- Terry L Jue
- Department of Gastroenterology, The Permanente Medical Group, San Francisco, California, USA
| | - Andrew C Storm
- Department of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, USA
| | - Mariam Naveed
- Advent Health Medical Group, Gastroenterology/Hepatology, Advent Health Hospital Altamonte Springs, Altamonte Springs, Florida, USA
| | - Douglas S Fishman
- Section of Pediatric Gastroenterology, Hepatology and Nutrition, Baylor College of Medicine, Texas Children's Hospital, Houston, Texas, USA
| | - Bashar J Qumseya
- Department of Gastroenterology, University of Florida, Gainesville, Florida, USA
| | - Autumn J McRee
- Division of Hematology/Oncology, University of North Carolina School of Medicine, Chapel Hill, North Carolina, USA
| | - Mark J Truty
- Department of Surgical Oncology, Mayo Clinic, Rochester, Minnesota, USA
| | - Mouen A Khashab
- Division of Gastroenterology and Hepatology, Johns Hopkins University, Baltimore, Maryland, USA
| | - Deepak Agrawal
- Department of Internal Medicine, Dell Medical School, University of Texas at Austin, Austin, Texas, USA
| | - Mohammed Al-Haddad
- Division of Gastroenterology and Hepatology, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Stuart K Amateau
- Division of Gastroenterology, Hepatology and Nutrition, University of Minnesota, Minneapolis, Minnesota, USA
| | - James L Buxbaum
- Division of Gastrointestinal and Liver Diseases, Keck School of Medicine of University of Southern California, Los Angeles, California, USA
| | - Audrey H Calderwood
- Department of Gastroenterology and Hepatology, Geisel School of Medicine, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire, USA
| | - John DeWitt
- Division of Gastroenterology and Hepatology, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | | | - Larissa L Fujii-Lau
- Department of Gastroenterology, The Queen's Medical Center, Honolulu, Hawaii, USA
| | - Suryakanth R Gurudu
- Department of Gastroenterology and Hepatology, Mayo Clinic Arizona, Scottsdale, Arizona, USA
| | - Laith H Jamil
- Section of Gastroenterology and Hepatology, Beaumont Health, Royal Oak, Michigan, USA
| | - Richard S Kwon
- Department of Gastroenterology, University of Michigan, Ann Arbor, Michigan, USA
| | - Joanna K Law
- Department of Gastroenterology and Hepatology, Digestive Disease Institute, Virginia Mason Medical Center, Seattle, Washington, USA
| | - Jeffrey K Lee
- Department of Gastroenterology, Kaiser Permanente San Francisco Medical Center, San Francisco, California, USA
| | - Swati Pawa
- Department of Gastroenterology, Wake Forest School of Medicine, Winston-Salem, North Carolina, USA
| | - Mandeep S Sawhney
- Division of Gastroenterology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - Nirav C Thosani
- Division of Gastroenterology, Hepatology and Nutrition, McGovern Medical School, UTHealth, Houston, Texas, USA
| | - Julie Yang
- Division of Gastroenterology, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York, USA
| | - Sachin B Wani
- Division of Gastroenterology and Hepatology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| |
Collapse
|
12
|
Tringali A, Costa D, Anderloni A, Carrara S, Repici A, Adler DG. Covered versus uncovered metal stents for malignant gastric outlet obstruction: a systematic review and meta-analysis. Gastrointest Endosc 2020; 92:1153-1163.e9. [PMID: 32565187 DOI: 10.1016/j.gie.2020.06.033] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 06/07/2020] [Indexed: 02/08/2023]
Abstract
BACKGROUND AND AIMS Self-expandable metal stents (SEMSs) are used for palliation of malignant gastric outlet obstruction (GOO). Studies comparing covered SEMSs (C-SEMSs) and uncovered SEMSs (U-SEMSs) have led to inconclusive results. We compared efficacy and safety of C-SEMSs versus U-SEMSs in patients with GOO. METHODS We searched MEDLINE, EMBASE, and Cochrane Library from 2000 to 2019 to identify available studies comparing C-SEMSs versus U-SEMSs in patients with GOO. Primary outcomes were stent survival and patient survival, whereas secondary outcomes were clinical and technical success, Gastric Outlet Obstruction Score System (GOOSS) score after the procedure, overall adverse events, reintervention rate, dysfunction rate, stent occlusion, and stent migration. RESULTS Overall, 7 randomized controlled trials and 9 observational studies were identified that included 1741 patients. C-SEMSs were associated with higher stent survival (hazard ratio, .68; 95% confidence interval [CI], .48-.96), whereas patient survival did not statistically significantly differ between C-SEMS and U-SEMS groups (hazard ratio, .96; 95% CI, .75-1.23). Clinical and technical success were not statistically different between groups (odds ratios, 1.1 [95% CI, .76-1.61] and .69 [95% CI, .21-2.3], respectively). There were no differences in terms of overall adverse events, reintervention rate, dysfunction rate, and GOOSS rate ≥2 after SEMS placement. U-SEMSs were associated with a higher rate of occlusion (odds ratio, .34; 95% CI, .21-.53) and C-SEMSs with a higher rate of migration (odds ratio, 4.28; 95% CI, 2.79-6.57). CONCLUSIONS C-SEMSs were associated with higher stent survival (time between stent deployment and stent dysfunction) compared with U-SEMSs, whereas no differences in terms of patient survival (time between stent deployment and patient's death) emerged. However, U-SEMSs were associated with higher risk of occlusion and C-SEMSs with higher risk of migration. Further studies using new C-SEMSs with an antimigration system are needed.
Collapse
Affiliation(s)
| | - Deborah Costa
- Endoscopy Unit, Conegliano Hospital Italy, Conegliano, Italy
| | | | | | | | - Douglas G Adler
- Division of Gastroenterology and Hepatology, University of Utah Hospital, Salt Lake City, Utah, USA
| |
Collapse
|
13
|
Tringali A, Costa D, Anderloni A, Carrara S, Repici A, Adler DG. Covered versus uncovered metal stents for malignant gastric outlet obstruction: a systematic review and meta-analysis. Gastrointest Endosc 2020; 92:1153-1163.e9. [DOI: 10.1016/j.gie.2020.06.033 pmid: 32565187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/16/2025]
|
14
|
Minervini A, Lauro A, Pagano N, Vaccari S, D'Andrea V, Marino IR, Cervellera M, Tonini V. The Great View Forward: The Use of a Colonoscope for Distal Duodenal Stent Placement. Dig Dis Sci 2019; 64:2445-2448. [PMID: 31410750 DOI: 10.1007/s10620-019-05768-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
INTRODUCTION Stent placement in the distal duodenum can be difficult. We describe a case report of a 94-year-old man with metastatic pancreatic head cancer compressing the third and fourth portions of the duodenum, treated by endoscopic stent placement using a colonoscope. AREAS COVERED A literature review highlighted two possible procedures for stent placement in the distal duodenum, namely forward-viewing and side-viewing endoscopies. Gastroscopes, duodenoscopes, enteroscopes, and colonoscopes have all been suggested for the purpose. For distal lesions, especially when the duodenal wall is stiffened due to compression or infiltration by neoplastic lesions, a conventional upper endoscope can be too short to reach the narrowed site in "push mode," necessitating the use of a longer endoscope. EXPERT COMMENTARY A colonoscope can be safely and effectively used to accomplish distal duodenal stent placement.
Collapse
Affiliation(s)
- A Minervini
- Department of Emergency Surgery and Gastroenterology, St. Orsola University Hospital, Bologna, Italy
| | - A Lauro
- Department of Emergency Surgery and Gastroenterology, St. Orsola University Hospital, Bologna, Italy.
| | - N Pagano
- Department of Emergency Surgery and Gastroenterology, St. Orsola University Hospital, Bologna, Italy
| | - S Vaccari
- Department of Emergency Surgery and Gastroenterology, St. Orsola University Hospital, Bologna, Italy
| | - V D'Andrea
- Department of Surgical Sciences, Umberto I Hospital, La Sapienza University, Rome, Italy
| | - I R Marino
- Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, USA
| | - M Cervellera
- Department of Emergency Surgery and Gastroenterology, St. Orsola University Hospital, Bologna, Italy
| | - V Tonini
- Department of Emergency Surgery and Gastroenterology, St. Orsola University Hospital, Bologna, Italy
| |
Collapse
|
15
|
Down CJ, Kumar L, Singh S, Veeramootoo D. A unique complication of self-expandable metal stent placement in malignant duodenal obstruction. J Surg Case Rep 2017; 2017:rjx169. [PMID: 28928926 PMCID: PMC5597866 DOI: 10.1093/jscr/rjx169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2017] [Accepted: 08/29/2017] [Indexed: 11/12/2022] Open
Abstract
Intestinal obstruction is a common complication in patients with advanced gastrointestinal malignancies. In the last two decades, endoscopic placement of duodenal stents has become a mainstay of palliative treatment in patients with unresectable obstructive duodenal pathology. Self-expandable metal stents have been reported to have excellent success rates, besides dramatically improve the patient's quality of life by reinstating the oral feeding ability. Re-intervention rates remain high, commonly as a consequence of tumour ingrowth resulting stent occlusion. We describe a unique case of duodenal stent obstruction secondary to impacted gallstones. To the best of our knowledge, this is the first case described in the literature and should alert clinicians to this unusual complication.
Collapse
Affiliation(s)
- Christopher J Down
- Department of General Surgery, Frimley Health NHS Foundation Trust, Frimley, GU16 7UJ, UK
| | - Lalit Kumar
- Department of General Surgery, Frimley Health NHS Foundation Trust, Frimley, GU16 7UJ, UK
| | - Sukhpal Singh
- Department of General Surgery, Frimley Health NHS Foundation Trust, Frimley, GU16 7UJ, UK
| | - Darmarajah Veeramootoo
- Department of General Surgery, Frimley Health NHS Foundation Trust, Frimley, GU16 7UJ, UK
| |
Collapse
|
16
|
Hamada T, Hakuta R, Takahara N, Sasaki T, Nakai Y, Isayama H, Koike K. Covered versus uncovered metal stents for malignant gastric outlet obstruction: Systematic review and meta-analysis. Dig Endosc 2017; 29:259-271. [PMID: 27997723 DOI: 10.1111/den.12786] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2016] [Accepted: 12/14/2016] [Indexed: 02/06/2023]
Abstract
BACKGROUND AND AIM Self-expandable metal stents (SEMS) are used for non-resectable malignant gastric outlet obstruction (GOO). Studies of covered versus uncovered SEMS have yielded inconsistent results as a result of heterogeneity in design and patient population. We carried out a meta-analysis to compare covered and uncovered gastroduodenal SEMS. METHODS Using MEDLINE, Embase, and the Cochrane database, we identified 1624 patients from 13 prospective and retrospective studies that evaluated covered and uncovered SEMS for malignant GOO and were published until October 2016. We pooled data on SEMS dysfunction, technical and clinical success, and adverse events using the fixed-effect or random-effects model. RESULTS Compared with uncovered SEMS, covered SEMS did not show any significant difference in stent dysfunction risk (risk ratio [RR], 1.02; 95% confidence interval [CI], 0.79-1.32). A subgroup analysis of five randomized trials suggested a trend toward a lower dysfunction risk in covered SEMS (RR, 0.63; 95% CI, 0.45-0.88). Covered SEMS were associated with a lower occlusion risk (RR, 0.44; 95% CI, 0.28-0.68), but with a higher migration risk (RR, 4.28; 95% CI, 2.89-6.34). Technical and clinical success rates were comparable between the groups. Overall adverse events tended to be more frequent in covered SEMS (RR, 1.75; 95% CI, 1.09-2.83). CONCLUSIONS Outcomes of covered and uncovered gastroduodenal SEMS were comparable, although the lower dysfunction rate of covered SEMS observed in the analysis of randomized trials needs further investigation. Antimigration mechanisms for covered SEMS and identification of patients who can achieve longer patency from uncovered SEMS would help improve the outcomes of gastroduodenal SEMS.
Collapse
Affiliation(s)
- Tsuyoshi Hamada
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokoyo, Japan.,Department of Medical Oncology, Dana-Farber Cancer Institute and Harvard Medical School, Boston, USA
| | - Ryunosuke Hakuta
- Department of Gastroenterology, Japanese Red Cross Medical Center, Tokoyo, Japan
| | - Naminatsu Takahara
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokoyo, Japan
| | - Takashi Sasaki
- Department of Hepato-Biliary-Pancreatic Medicine, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
| | - Yousuke Nakai
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokoyo, Japan
| | - Hiroyuki Isayama
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokoyo, Japan
| | - Kazuhiko Koike
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokoyo, Japan
| |
Collapse
|
17
|
Singer JL, Aryaie AH, Fayezizadeh M, Lash J, Marks JM. Predictive Factors for the Migration of Endoscopic Self-Expanding Metal Stents Placed in the Foregut. Surg Innov 2017; 24:353-357. [PMID: 28385100 DOI: 10.1177/1553350617702026] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
BACKGROUND With recent advancements in endoscopy, self-expandable metal stents (SEMS) have been used to treat gastrointestinal leaks, perforations, and strictures. Stent migration frequently complicates management and often requires additional treatments to reach resolution. Our study aimed to determine predictive factors for stent migration. METHODS Consecutive procedures involving SEMS placed with and without fixation after upper gastrointestinal surgery between 2009 and 2014 were retrospectively reviewed. Demographic, surgical history, rate of stent migration, and stent characteristic data were collected. Rates of stent migration were compared. RESULTS We reviewed 214 consecutive procedures involving stents placed in the foregut. Median duration of stent placement was 4.0 ± 10.3 weeks. Forty-three (20%) stents migrated after placement. Of those, 27 (63%) required stent replacement. Eleven (5%) procedures utilized stent fixation and 203 (95%) did not. Fixation techniques included endoscopic clips (9%), endoscopic sutures (73%), and transnasal sutures (18%). Stent migration rate was not different between those with and those without fixation ( P = .2). Rate of migration was significantly higher in procedures involving fully covered stents ( P < .001). Migration occurred after esophagectomy and gastric bypass ( P < .001 and P < .05, respectively) and in patients with diabetes ( P < .01). CONCLUSIONS A challenge with SEMS use is stent migration. Diabetes and using fully covered stents were associated with migration as were SEMS used to treat complications of esophagectomy and gastric bypass. Stent fixation was not associated with the prevention of stent migration. No pattern was found that favors an approach to reduce stent migration.
Collapse
Affiliation(s)
- Jordan L Singer
- 1 University Hospitals Case Medical Center, Cleveland, OH, USA.,2 Case Western Reserve University School of Medicine, Cleveland, OH, USA
| | - Amir H Aryaie
- 1 University Hospitals Case Medical Center, Cleveland, OH, USA
| | | | - Jon Lash
- 1 University Hospitals Case Medical Center, Cleveland, OH, USA
| | - Jeffrey M Marks
- 1 University Hospitals Case Medical Center, Cleveland, OH, USA
| |
Collapse
|
18
|
Grunwald D, Cohen J, Bartley A, Sheridan J, Chuttani R, Sawhney MS, Pleskow DK, Berzin TM, Mizrahi M. The location of obstruction predicts stent occlusion in malignant gastric outlet obstruction. Therap Adv Gastroenterol 2016; 9:815-822. [PMID: 27803736 PMCID: PMC5076776 DOI: 10.1177/1756283x16667893] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
BACKGROUND Gastric outlet obstruction (GOO) can occur with locally invasive or metastatic cancer involving the upper gastrointestinal tract at the pylorus or the duodenum. Endoscopic management with self-expanding metal stents (SEMSs) is often the preferred palliative approach. Stent occlusion is a common reason for failure and reintervention. We set out to determine whether the location of the malignant obstruction is associated with the angulation of the stent and can predict stent occlusion. METHODS We performed a retrospective review of consecutive patients who underwent successful duodenal stenting with SEMS for malignant GOO between 2006 and 2015 at a large advanced endoscopy referral center. We determined the location of obstruction, the stent angle, and the rate of technical and clinical success of stent placement. We then identified cases of subsequent stent occlusion confirmed by endoscopic evaluation. RESULTS A total of 100 consecutive patients were included in the study; 91 of these patients had enough data to evaluate SEMS occlusion. A total of 21 patients (23%) developed stent occlusion with a median time of 39 days. The risk of occlusion sequentially increased as the obstruction occurred more distally from the antrum to the third or fourth portion of the duodenum (p = 0.006). This relationship was maintained after controlling for stent angle (p = 0.05). CONCLUSIONS A distal location of malignant GOO was strongly predictive of stent occlusion, independent of stent angle. This may be due to longer and more complex distal obstructions, along with foreshortening of the stent during placement and tumor infiltration. If replicated, these results will have implications for endoscopic practice and future device development.
Collapse
Affiliation(s)
| | - Jonah Cohen
- Center for Advanced Endoscopy, Division of Gastroenterology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - Anthony Bartley
- Center for Advanced Endoscopy, Division of Gastroenterology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - Jennifer Sheridan
- Center for Advanced Endoscopy, Division of Gastroenterology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - Ram Chuttani
- Center for Advanced Endoscopy, Division of Gastroenterology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - Mandeep S. Sawhney
- Center for Advanced Endoscopy, Division of Gastroenterology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - Douglas K. Pleskow
- Center for Advanced Endoscopy, Division of Gastroenterology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - Tyler M. Berzin
- Center for Advanced Endoscopy, Division of Gastroenterology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - Meir Mizrahi
- Center for Advanced Endoscopy, Division of Gastroenterology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| |
Collapse
|
19
|
Lopera JE, Gregorio MAD, Laborda A, Casta?o R. Enteral stents: Complications and their management. INTERNATIONAL JOURNAL OF GASTROINTESTINAL INTERVENTION 2016. [DOI: 10.18528/gii160005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Affiliation(s)
- Jorge E. Lopera
- Department of Radiology, UT Health Science Center at San Antonio, San Antonio, TX, USA
| | | | - Alicia Laborda
- Minimally Invasive Techniques Research Group (GITMI), University of Zaragoza, Zaragoza, Spain
| | - Rodrigo Casta?o
- Gastrohepatology Group, Universidad de Antioquia, Medell?n, Colombia
| |
Collapse
|
20
|
Laasch HU, Edwards DW, Song HY. Enteral stent construction: Current principles. GASTROINTESTINAL INTERVENTION 2016. [DOI: 10.18528/gii160009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Hans-Ulrich Laasch
- Department of Radiology, The Christie NHS Foundation Trust, Manchester, UK
| | - Derek W. Edwards
- Department of Radiology, The Christie NHS Foundation Trust, Manchester, UK
| | - Ho-Young Song
- Department of Radiology, Asan Medical Center, Seoul, Korea
| |
Collapse
|
21
|
Lee F, Lee F, Abdul-Halim R, Abdul-Halim R, Dickinson O, Dickinson O, Maetani I. Malignant gastroduodenal obstruction: An endoscopic approach. INTERNATIONAL JOURNAL OF GASTROINTESTINAL INTERVENTION 2016. [DOI: 10.18528/gii160018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Affiliation(s)
| | - Fred Lee
- Medical Imaging and Medical Physics, Sheffield Teaching Hospitals, Sheffield, UK
| | | | - Rehan Abdul-Halim
- Medical Imaging and Medical Physics, Sheffield Teaching Hospitals, Sheffield, UK
| | | | - Owen Dickinson
- Medical Imaging and Medical Physics, Sheffield Teaching Hospitals, Sheffield, UK
| | - Iruru Maetani
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Toho University Ohashi Medical Center, Tokyo, Japan
| |
Collapse
|