1
|
Li J, Zhu S, Juan J, Yi B. Preliminary exploration of robotic complete mesocolic excision for colon cancer with the domestically produced Chinese minimally invasive Micro Hand S surgical robot system. Int J Med Robot 2020; 16:1-8. [PMID: 32865308 DOI: 10.1002/rcs.2148] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 07/31/2020] [Accepted: 08/11/2020] [Indexed: 12/11/2022]
Abstract
OBJECTIVE To summarize our initial experience with robot-assisted complete mesocolic excision (R-CME) using a domestically produced Chinese surgical robot by a short-term evaluation. METHODS From March 2018 to December 2018, 25 patients with colon cancer underwent Micro Hand S R-CME. The operative findings, morbidities and oncological findings were analysed. RESULT The median operative duration was 210 (range, 180-235) min, and the median estimated blood loss volume was 55 (range, 25-125) ml. The median number of lymph nodes harvested was 42 (range, 21-77), and the median length of hospital stay after the operation was 7 (range, 5-9) days. There were no severe complications except for seven cases of grade I complications and five cases of grade II complications. The conversion rate was 0%. There were no cases of 30-day readmission or 30-day mortality. CONCLUSION R-CME using a domestically produced surgical robot for selected colon cancer patients is technically feasible and safe.
Collapse
Affiliation(s)
- Jianmin Li
- School of Mechanical Engineering, Tianjin University, Tianjin, China
| | - Shaihong Zhu
- Department of General Surgery, Third Xiangya Hospital, Central South University, Changsha, Hunan, China
| | - Jiang Juan
- Department of General Surgery, Third Xiangya Hospital, Central South University, Changsha, Hunan, China
| | - Bo Yi
- Department of General Surgery, Third Xiangya Hospital, Central South University, Changsha, Hunan, China
| |
Collapse
|
2
|
Wilhelm D, Vogel T, Neumann PA, Friess H, Kranzfelder M. Complete mesocolic excision in minimally invasive surgery of colonic cancer: do we need the robot? Eur Surg 2020. [DOI: 10.1007/s10353-020-00677-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Summary
Background
Robotic surgery offers favorable prerequisites for complex minimally invasive surgeries which are delivered by higher degrees of freedom, improved instrument stability, and a perfect visualization in 3D which is fully surgeon controlled. In this article we aim to assess its impact on complete mesocolic excision (CME) in colon cancer and to answer the question of whether the current evidence expresses a need for robotic surgery for this indication.
Methods
Retrospective analysis and review of the current literature on complete mesocolic excision for colon cancer comparing the outcome after open, laparoscopic, and robotic approaches.
Results
Complete mesocolic excision results in improved disease-free survival and reduced local recurrence, but turns out to be complex and prone to complications. Introduced in open surgery, the transfer to minimally invasive surgery resulted in comparable results, however, with high conversion rates. In comparison, robotic surgery shows a reduced conversion rate and a tendency toward higher lymph node yield. Data, however, are insufficient and no high-quality studies have been published to date. Almost no oncologic follow-up data are available in the literature.
Conclusion
The current data do not allow for a reliable conclusion on the need of robotic surgery for CME, but show results which hypothesize an equivalence if not superiority to laparoscopy. Due to recently published technical improvements for robotic CME and supplementary features of this method, we suppose that this approach will gain in importance in the future.
Collapse
|
3
|
Zeng Y, Wang G, Liu Y, Li Z, Yi B, Zhu S. The "Micro Hand S" Robot-Assisted Versus Conventional Laparoscopic Right Colectomy: Short-Term Outcomes at a Single Center. J Laparoendosc Adv Surg Tech A 2020; 30:363-368. [PMID: 32013727 DOI: 10.1089/lap.2019.0714] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
Objective: To evaluate the safety and feasibility of using the Micro Hand S surgical robot for right colectomy by comparing the short-term efficacy of robot-assisted and laparoscopic right colectomy (LRC). Methods: Data from a total of 22 patients who underwent right colectomy from January 2018 to February 2019 in the Department of Gastrointestinal Surgery, in the Third Xiangya Hospital of Central South University, were collected retrospectively. This included 10 patients who underwent robot-assisted right colectomy with the Micro Hand S surgical robot (RRC group [Shangdong Wego Surgical Robot Co., LTD, Weihai, China]) and 12 patients who underwent LRC group. The operation time, blood loss, number of lymph nodes dissected, time to first flatus, comprehensive complication index (CCI), and postoperative hospital stay were compared. Results: Compared with the LRC group, the RRC group had a lower CCI (11.7 ± 8.3 versus 19.9 ± 6.4, P < .05), shorter hospital stay (11.4 ± 3.3 versus 15.2 ± 4.7 days, P < .05). The differences were statistically significant. Conclusion: The Micro Hand S robot-assisted right colectomy is safe and feasible.
Collapse
Affiliation(s)
- Yijia Zeng
- Department of General Surgery, Third Xiangya Hospital, Central South University, Changsha, Hunan, China
| | - Guohui Wang
- Department of General Surgery, Third Xiangya Hospital, Central South University, Changsha, Hunan, China
| | - Yong Liu
- Department of General Surgery, Third Xiangya Hospital, Central South University, Changsha, Hunan, China
| | - Zheng Li
- Department of General Surgery, Third Xiangya Hospital, Central South University, Changsha, Hunan, China
| | - Bo Yi
- Department of General Surgery, Third Xiangya Hospital, Central South University, Changsha, Hunan, China
| | - Shaihong Zhu
- Department of General Surgery, Third Xiangya Hospital, Central South University, Changsha, Hunan, China
| |
Collapse
|
4
|
Young R, Rajkomar A, Smart P, Warrier S. Robotic-assisted complete mesocolic excision, central vascular ligation and para-aortic lymph node dissection in multifocal carcinoid: A case report and technical description. Int J Surg Case Rep 2020; 67:262-266. [PMID: 32092693 PMCID: PMC7036704 DOI: 10.1016/j.ijscr.2020.02.018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Accepted: 02/06/2020] [Indexed: 11/29/2022] Open
Abstract
Neuroendocrine tumours are the most common type of small bowel neoplasm. Robotic technique may be superior to open technique for lymph node dissection. Robotic-assisted complete mesocolic excision is a safe and effective technique.
Introduction Neuroendocrine tumours are the most common type of primary small bowel neoplasm. Consensus guidelines recommend a multimodal approach to treatment of such tumours, with aggressive surgical resection remaining the mainstay of management. There is evidence that complete mesocolic excision (CME) of lymph nodes is associated with superior oncological outcomes including longer disease-free survival in patients with colorectal cancer than standard lymph node dissection and there is increasing evidence to suggest that the robotic approach may be superior to laparoscopic or open CME. This report discusses a robotic-assisted approach to CME with central vessel ligation (CVL) and para-aortic lymph node dissection in a case of multifocal neuroendocrine tumour of the small bowel. Presentation of case and technical approach This report details the case of a 73-year-old male with multifocal small bowel neuroendocrine tumour. He underwent a robotic-assisted right hemicolectomy, small bowel resection, CME, CVL and para-aortic lymph node dissection. The approach described involved undertaking CME, CVL and bowel resection with a standard right hemicolectomy robotic set-up before re-docking the robot to perform the retroperitoneal para-aortic lymph node dissection. Discussion This case highlights the management of multifocal small bowel neuroendocrine tumour using a robotic approach for surgical resection and lymph node clearance. Conclusion The robotic approach provides a safe and effective technique for undertaking surgical resection of small bowel neuroendocrine tumour as well as complete mesocolic excision of lymph nodes. With a change in port positions, a robotic approach can be utilised for CME/CVL as well as retroperitoneal node dissection.
Collapse
Affiliation(s)
- R Young
- Department of Surgery, Melbourne Health, Melbourne, Victoria, Australia; Department of Cancer Surgery, Peter MacCallum Cancer Centre, Victoria, Australia.
| | - A Rajkomar
- Gastrointestinal Clinical Institute, Epworth Healthcare, Victoria, Australia
| | - P Smart
- Gastrointestinal Clinical Institute, Epworth Healthcare, Victoria, Australia; Department of Surgery, Austin Health, Victoria, Australia
| | - S Warrier
- Gastrointestinal Clinical Institute, Epworth Healthcare, Victoria, Australia; Department of Cancer Surgery, Peter MacCallum Cancer Centre, Victoria, Australia; Department of Surgery, Alfred Health, Victoria, Australia.
| |
Collapse
|
5
|
Sammour T, Malakorn S, Thampy R, Kaur H, Bednarski BK, Messick CA, Taggart M, Chang GJ, You YN. Selective central vascular ligation (D3 lymphadenectomy) in patients undergoing minimally invasive complete mesocolic excision for colon cancer: optimizing the risk-benefit equation. Colorectal Dis 2020; 22:53-61. [PMID: 31356721 DOI: 10.1111/codi.14794] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2019] [Accepted: 07/07/2019] [Indexed: 12/16/2022]
Abstract
AIM Complete mesocolic excision (CME) with central vascular ligation (CVL) has been advocated for right colon adenocarcinoma (RC), but the radicality of vascular dissection remains controversial. Our aim is to report outcomes of selective CVL (D3 lymphadenectomy) during minimally invasive CME for RC. METHOD A prospective database identified patients who were treated for RC between 2009 and 2016. Minimally invasive CME was standard. The radicality of lymphadenectomy was defined as high ligation (HL) versus CVL based on operative reports and videos. Two blinded radiologists independently evaluated the pre- and postoperative CT scans for radiographically abnormal nodes. RESULTS Of 197 patients who underwent CME, HL was performed in 56 (28%) and CVL in 141 (72%). There were no baseline differences in age, sex, body mass index, American Society of Anesthesiologists score or pathological staging, and there were no major intra-operative complications in either group (including no major vascular injuries). The median total number of nodes retrieved was 27 and 31 (P = 0.011) in HL and CVL groups, resepctively, with pathologically positive nodes identified in 33.9% and 39.8% (P = 0.704), respectively. Preoperative imaging identified abnormal cN3 nodes in 1.5% of patients; all of whom underwent CVL. No abnormal cN2 or cN3 nodes remained on postoperative imaging. The 60-day mortality was 0.5%, and major morbidity was 4%. One patient (0.5%) had an anastomotic recurrence after a median follow-up of 22 months. CONCLUSION With imperfect preoperative clinical nodal staging, and in the absence of randomized data, the low morbidity and oncological outcomes observed support the approach of CME with HL as a minimum standard, with CVL (D3 lymphadenectomy) in selected cases.
Collapse
Affiliation(s)
- T Sammour
- Department of Surgical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - S Malakorn
- Department of Surgical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - R Thampy
- Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - H Kaur
- Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - B K Bednarski
- Department of Surgical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - C A Messick
- Department of Surgical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - M Taggart
- Department of Pathology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - G J Chang
- Department of Surgical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Y N You
- Department of Surgical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| |
Collapse
|
6
|
Kudsi OY, Gokcal F. Urgent robotic mesocolic excision for obstructing proximal transverse colon cancer - a video vignette. Colorectal Dis 2019; 21:1093-1094. [PMID: 31116470 DOI: 10.1111/codi.14714] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Accepted: 05/01/2019] [Indexed: 02/08/2023]
Affiliation(s)
- O Y Kudsi
- Good Samaritan Medical Center, Tufts University School of Medicine, Brockton, Massachusetts, USA
| | - F Gokcal
- Good Samaritan Medical Center, Tufts University School of Medicine, Brockton, Massachusetts, USA
| |
Collapse
|
7
|
A standardized suprapubic bottom-to-up approach in robotic right colectomy: technical and oncological advances for complete mesocolic excision (CME). BMC Surg 2019; 19:72. [PMID: 31262302 PMCID: PMC6604440 DOI: 10.1186/s12893-019-0544-2] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Accepted: 06/24/2019] [Indexed: 02/07/2023] Open
Abstract
Backround Several studies have demonstrated a direct correlation between lymph node yield and survival after colectomy for cancer. Complete mesocolic excision (CME) in right colectomy (RC) reduces local recurrence but is technically demanding. Here we report our early single center experience with robotic right colectomy comparing our standardized bottom-to-up (BTU) approach of robotic RC with CME and central vessel ligation (CVL) facilitated by a suprapubic access with the “classical” medial-to-lateral (MTL) strategy. Methods A 4-step BTU approach of robotic RC guided by embryonal planes in the process of retrocolic mobilization with suprapubic port placement was performed in the BTU-group (n = 24; all with intention to treat cancer). In step 1 CME was initiated with caudolateral mobilization of the right colon guided by the fascia of Toldt across the duodenum and up to the Trunk of Henle. Subsequently, dissection was performed BTU right of the middle supramesenteric vessels with central ileocolic vessel ligation in step 2. Subsequent to separation of the transverse retromesenteric space and completion of mobilization the hepatic flexure in step 3, the transverse mesocolon was then transected right of the middle colic vessels in step 4. An extracorporeal side to side anastomosis was performed. We compared the outcome of the BTU-group with a MTL-group (n = 7). Results Patient characteristics like age, gender, BMI, comorbidity (ASA) and M-status were comparable among groups. There was no conversion. Overall complication rate was 35.5%. We experienced no anastomoses insufficiency, grade Dindo/Clavien III/IV complication or mortality in this study. Type I and II complications and surgical characteristics incl. OR-time, ICU- and hospital-stay were comparable between the two groups. However, the lymph node yield was superior in the BTU-group (mean 40.2 ± 17.1) when compared with the MTL-group (16,3 nodes ±8.5; p < 0,001). Conclusions Compared to the classical MTL approach, robotic suprapubic BTU RC changes from a search of the layers bordering the oncological dissection to a consequent utilization of the planes as a retro-mesocolic guide during CME. The BTU strategy could bear the potential to increase the lymph node yield. Robotic systems may provide the technical requirements to combine advantages of both open and minimally invasive RC.
Collapse
|
8
|
Huang YM, Huang YJ, Wei PL. Colorectal Cancer Surgery Using the Da Vinci Xi and Si Systems: Comparison of Perioperative Outcomes. Surg Innov 2019; 26:192-200. [PMID: 30501567 DOI: 10.1177/1553350618816788] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2025]
Abstract
PURPOSE Robotic surgery for colorectal cancer is an emerging technique. Potential benefits as compared with the conventional laparoscopic surgery have been demonstrated. However, experience with the previous da Vinci Si robotic system revealed several unsolved problems. The novel features of the new da Vinci Xi increase operational flexibility and maneuverability and are expected to facilitate the performance of multiquadrant surgery. METHODS Between December 2011 and May 2015, 120 patients with colon or rectal cancer were operated on using the Si robotic system (the Si group). Between May 2015 and October 2017, 60 more patients with colon or rectal cancer were operated on using the Xi robotic system (the Xi group). The clinicopathological characteristics and perioperative outcomes of these 2 groups of patients were compared. RESULTS The 2 groups of patients were comparable with regard to baseline clinical characteristics, types of resection performed, and the proportion of patients undergoing neoadjuvant chemoradiation therapy. The statuses of resection margin, the numbers of lymph nodes harvested, and the rates of postoperative complications were also similar between the 2 groups. Nevertheless, a lower rate of diverting ileostomy, a shorter operation time, less estimated blood loss, and a faster postoperative recovery was observed in the Xi group. CONCLUSIONS Colorectal cancer surgery using the Xi robotic system was associated with improved perioperative outcomes. These benefits may be attributed to its improved, more user-friendly design.
Collapse
Affiliation(s)
- Yu-Min Huang
- 1 Taipei Medical University, Taiwan
- 2 Taipei Medical University Hospital, Taiwan
| | - Yan Jiun Huang
- 1 Taipei Medical University, Taiwan
- 2 Taipei Medical University Hospital, Taiwan
| | - Po-Li Wei
- 1 Taipei Medical University, Taiwan
- 2 Taipei Medical University Hospital, Taiwan
| |
Collapse
|
9
|
Yozgatli TK, Aytac E, Ozben V, Bayram O, Gurbuz B, Baca B, Balik E, Hamzaoglu I, Karahasanoglu T, Bugra D. Robotic Complete Mesocolic Excision Versus Conventional Laparoscopic Hemicolectomy for Right-Sided Colon Cancer. J Laparoendosc Adv Surg Tech A 2019; 29:671-676. [PMID: 30807257 DOI: 10.1089/lap.2018.0348] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
Background: Robotic technique has been proposed to overcome the limitations of laparoscopic surgery. In this study, we aimed at determining whether robotic complete mesocolic excision (CME) for right-sided colon cancer can be safe and effective as conventional laparoscopic right hemicolectomy (CLRH). Materials and Methods: Between February 2015 and September 2017, patients undergoing robotic right CME and CLRH with curative intent for right-sided colon cancer were included. Patient characteristics, short-term and histopathological outcomes were compared between the groups. Results: Ninety-six patients (robotic, n = 35) were included in this study. The operative time (286 ± 77 versus 132 ± 40 minutes, P = .0001) was significantly longer in the robotic group. There were no conversions in either group. No significant differences existed between the groups regarding the mean estimated blood loss, time to first flatus, length of hospital stay (6 ± 3 versus 6 ± 3 days, P = .64), and follow-up times (robotic 15 ± 8 versus laparoscopic 16 ± 10 months P = .11). Overall complication rates (n = 10 [29%] versus n = 15 [25%], P = .67) were similar. In the robotic group, vascular injury occurred in 2 patients, and both were repaired robotically. The mean number of harvested lymph nodes was significantly higher (41 ± 12 versus 33 ± 10, P = .04) and length between the vascular tie and colonic wall was longer (13 ± 3.5 versus 11 ± 3, P = .02) in the robotic group. Conclusion: Although robotic right CME seems equally safe to CLRH in terms of short-term morbidity, future prospective randomized trials are needed to define its role for treatment of right colectomy.
Collapse
Affiliation(s)
- Tahir K Yozgatli
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University School of Medicine, Istanbul, Turkey
| | - Erman Aytac
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University School of Medicine, Istanbul, Turkey
| | - Volkan Ozben
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University School of Medicine, Istanbul, Turkey
| | - Onur Bayram
- Department of General Surgery, Koc University School of Medicine, Istanbul, Turkey
| | - Bulent Gurbuz
- Department of General Surgery, Koc University School of Medicine, Istanbul, Turkey
| | - Bilgi Baca
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University School of Medicine, Istanbul, Turkey
| | - Emre Balik
- Department of General Surgery, Koc University School of Medicine, Istanbul, Turkey
| | - Ismail Hamzaoglu
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University School of Medicine, Istanbul, Turkey
| | - Tayfun Karahasanoglu
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University School of Medicine, Istanbul, Turkey
| | - Dursun Bugra
- Department of General Surgery, Koc University School of Medicine, Istanbul, Turkey
| |
Collapse
|
10
|
Ma S, Chen Y, Chen Y, Guo T, Yang X, Lu Y, Tian J, Cai H. Short-term outcomes of robotic-assisted right colectomy compared with laparoscopic surgery: A systematic review and meta-analysis. Asian J Surg 2018; 42:589-598. [PMID: 30503268 DOI: 10.1016/j.asjsur.2018.11.002] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2018] [Revised: 10/27/2018] [Accepted: 11/02/2018] [Indexed: 12/22/2022] Open
Abstract
To assess the clinical efficacy and safety of robotic-assisted right colectomy (RRC) with conventional laparoscopic right colectomy (LRC) by performing a systematic review and meta-analysis of the published studies. All published literature for comparative studies reporting preoperative outcomes of RRC and LRC were searched. We searched the databases included Cochrane Library of Clinical Comparative Trials, MEDLINE, Embase, Web of Science and Chinese Biomedical Database (CBM) from 1973 to 2018. The censor date was up to January 2018. Operative time, estimated blood loss, length of hospital stay, conversion rates to open surgery, postoperative complications, and related outcomes were evaluated. All calculations and statistical tests were performed using Stata 12.0 software. A total of 7769 patients with colon cancer enrolled in 13 trials were divided into a study group (n = 674) and a control group (n = 7095). Meta-analysis suggested significantly greater length of hospital stay in the LRC group [MD = -0.85; 95% CI: -1.07 to -0.63; P < 0.00001]. Robotic surgery was also associated with a significantly lower complication rate [OR = 0.73; 95% CI: 0.52 to 1.01; P = 0.05]. There were statistically significant differences between the groups in estimated blood loss [MD = -16.89; 95% CI: -24.80 to -8.98; P < 0.00001] and the rate of intraoperative conversion to open surgery [OR = 0.34, 95% CI: 0.15 to 0.75; P = 0.008)], but these differences were not clinically relevant. The recovery of bowel function in two groups is no significant differences [MD = -0.58, 95% CI: -0.96 to -0.20, P = 0.0008]. However, operation times [MD = 43.61, 95% CI: 39.11 to 48.10, P < 0.00001] were longer for RRC than for LRC. Compared to LRC, RRC was associated with reduced estimated blood loss, reduced postoperative complications, longer operation times. Recovery of bowel function and other perioperative outcomes were equivalent between the two surgeries.
Collapse
Affiliation(s)
- Shixun Ma
- Gansu Province Hospital, Lanzhou, China.
| | - Yan Chen
- The First Affiliated Hospital of Soochow University, Jiangsu, China.
| | | | | | | | - Yufeng Lu
- Gansu Province Hospital, Lanzhou, China.
| | | | - Hui Cai
- Gansu Province Hospital, Lanzhou, China.
| |
Collapse
|
11
|
Mégevand JL, Amboldi M, Lillo E, Lenisa L, Ganio E, Ambrosi A, Rusconi A. Right colectomy: consecutive 100 patients treated with laparoscopic and robotic technique for malignancy. Cumulative experience in a single centre. Updates Surg 2018; 71:151-156. [PMID: 30448923 DOI: 10.1007/s13304-018-0599-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2018] [Accepted: 10/08/2018] [Indexed: 12/11/2022]
Abstract
Robotic-assisted resections prove beneficial in overcoming potential limitation of laparoscopy, but clear evidences on patient's benefits are still lacking. We report our experience on 100 consecutive patients who underwent right colectomy with either robotic or laparoscopic approaches. Data were prospectively collected on a dedicated database (ASA score, age, operative time, conversion rate, re-operation rate, early complications, length of stay, and pathological results). Median total operative time was 160 min in LS group (IQR = 140-180) and 204 min for RS group (IQR = 180-230). Median time to first flatus was 2.5 days for LS group (IQR = 2 - 3) and 2 days for RS group (IQR = 1-2). Length of stay (median) was 8 days in LS group (IQR = 6-10) and 5 days in RS group (IQR = 5-7). No statistically significant difference was found between the 2 groups when the number of harvested nodes, the anastomotic leakage and the postoperative bleeding were analyzed. The 30-day mortality was 0% in LS and RS groups. Conversion rate for LS group was 14% (7/50 pts) and for RS group was 0% (0/50). Minimally invasive surgery is a feasible and safe technique. The RS may overcome some technical limitations of laparoscopic surgery and it achieves the same oncological results compared to LS but with higher costs. The lower conversion rate allows to expect better clinical outcomes and lower complication rate.
Collapse
Affiliation(s)
- J L Mégevand
- Division of General Surgery, Department of Surgery, Humanitas S. Pio X Hospital, Via Nava 31, 20159, Milan, Italy.
| | - M Amboldi
- Division of General Surgery, Department of Surgery, Humanitas S. Pio X Hospital, Via Nava 31, 20159, Milan, Italy
| | - E Lillo
- Division of General Surgery, Department of Surgery, Humanitas S. Pio X Hospital, Via Nava 31, 20159, Milan, Italy
| | - L Lenisa
- Division of General Surgery, Department of Surgery, Humanitas S. Pio X Hospital, Via Nava 31, 20159, Milan, Italy
| | - E Ganio
- Division of General Surgery, Department of Surgery, Humanitas S. Pio X Hospital, Via Nava 31, 20159, Milan, Italy
| | - A Ambrosi
- Vita-Salute San Raffaele University, 20132, Milan, Italy
| | - A Rusconi
- Division of General Surgery, Department of Surgery, Humanitas S. Pio X Hospital, Via Nava 31, 20159, Milan, Italy
| |
Collapse
|
12
|
Spinoglio G, Bianchi PP, Marano A, Priora F, Lenti LM, Ravazzoni F, Petz W, Borin S, Ribero D, Formisano G, Bertani E. Robotic Versus Laparoscopic Right Colectomy with Complete Mesocolic Excision for the Treatment of Colon Cancer: Perioperative Outcomes and 5-Year Survival in a Consecutive Series of 202 Patients. Ann Surg Oncol 2018; 25:3580-3586. [DOI: 10.1245/s10434-018-6752-7] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2018] [Indexed: 12/16/2022]
|
13
|
Hamzaoglu I, Ozben V, Sapci I, Aytac E, Aghayeva A, Bilgin IA, Bayraktar IE, Baca B, Karahasanoglu T. "Top down no-touch" technique in robotic complete mesocolic excision for extended right hemicolectomy with intracorporeal anastomosis. Tech Coloproctol 2018; 22:607-611. [PMID: 30083781 DOI: 10.1007/s10151-018-1831-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/08/2017] [Accepted: 07/31/2018] [Indexed: 12/25/2022]
Abstract
BACKGROUND Proper identification of the mesocolic vessels is essential for achieving complete mesocolic excision (CME) in cases of colon cancer requiring an extended right hemicolectomy. In robotic procedures, we employed a "top down technique" to allow early identification of the gastrocolic trunk and middle colic vessels. The aim of our study was to illustrate the details of this technique in a series of 12 patients. METHODS The top down technique consists of two steps. First, the omental bursa was entered to identify the right gastroepiploic vein. Tracing down this vein as a landmark, the gastrocolic trunk was exposed, branches of this trunk and the middle colic vessels were divided. Second, dissection was directed to the ileocolic region and proceeded in an inferior-to-superior direction along the superior mesenteric vein to divide the ileocolic and right colic vessels consecutively. The ileotranverse anastomosis was created intracorporeally. RESULTS There were 8 males and 4 females with a mean age of 64.8 ± 16.9 years and a mean body mass index of 25.6 ± 3.7 kg/m2. All the procedures were completed successfully. No conversions occurred. The mean operative time and blood loss were 312.1 ± 93.9 min and 110.0 ± 89.9 ml, respectively. The mean number of harvested lymph nodes was 45.2 ± 11.1. The mean length of hospital stay was 7.6 ± 4.7 days. Two patients had intraoperative complications and two had postoperative complications. There was no disease recurrence at a mean follow-up period of 10.4 ± 7.1 months. CONCLUSIONS The top down technique appears to be useful in robotic CME for an extended right hemicolectomy. Early identification of the gastrocolic trunk and middle colic vessels via this technique may prevent inadvertent vascular injury at the mesenteric root of the transverse colon.
Collapse
Affiliation(s)
- I Hamzaoglu
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University, School of Medicine, Istanbul, Turkey.
| | - V Ozben
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University, School of Medicine, Istanbul, Turkey
| | - I Sapci
- Acibadem Mehmet Ali Aydinlar University, School of Medicine, Istanbul, Turkey
| | - E Aytac
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University, School of Medicine, Istanbul, Turkey
| | - A Aghayeva
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University, School of Medicine, Istanbul, Turkey
| | - I A Bilgin
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University, School of Medicine, Istanbul, Turkey
| | - I E Bayraktar
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University, School of Medicine, Istanbul, Turkey
| | - B Baca
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University, School of Medicine, Istanbul, Turkey
| | - T Karahasanoglu
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University, School of Medicine, Istanbul, Turkey
| |
Collapse
|
14
|
Ozben V, Aytac E, Atasoy D, Erenler Bayraktar I, Bayraktar O, Sapci I, Baca B, Karahasanoglu T, Hamzaoglu I. Totally robotic complete mesocolic excision for right-sided colon cancer. J Robot Surg 2018; 13:107-114. [PMID: 29774501 DOI: 10.1007/s11701-018-0817-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Accepted: 04/23/2018] [Indexed: 12/12/2022]
Abstract
Complexity and operative risks of complete mesocolic excision (CME) seem to be important drawbacks to generalize this procedure in the surgical treatment of right colon cancer. Robotic systems have been developed to improve quality and outcomes of minimal invasive surgery. The aim of this study was to evaluate the feasibility of robotic right-sided CME and present our initial experience. A retrospective review of 37 patients undergoing totally robotic right-sided CME between February 2015 and November 2017 was performed. All the operations were carried out using the key principles of both CME with intracorporeal anastomosis and no-touch technique. Data on perioperative clinical findings and short-term outcomes were analyzed. There were 20 men and 17 women with a mean age of 64.4 ± 13.5 years and a body mass index of 26.8 ± 5.7 kg/m2. The mean operative time and estimated blood loss were 289.8 ± 85.3 min and 77.4 ± 70.5 ml, respectively. Conversion to laparoscopy occurred in one patient (2.7%). All the surgical margins were clear and the mesocolic plane surgery was achieved in 27 (72.9%) of the cases. The mean number of harvested lymph nodes was 41.8 ± 11.9 (median, 40; range 22-65). The mean length of hospital stay was 6.6 ± 3.7 days. The intraoperative and postoperative complication rates were 5.4 and 21.6%, respectively. We believe that use of robot for right-sided CME is feasible and appears to provide remarkably a high number of harvested lymph nodes with good specimen quality.
Collapse
Affiliation(s)
- Volkan Ozben
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University, School of Medicine, Istanbul, Turkey
| | - Erman Aytac
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University, School of Medicine, Istanbul, Turkey
| | - Deniz Atasoy
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University, School of Medicine, Istanbul, Turkey
| | - Ilknur Erenler Bayraktar
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University, School of Medicine, Istanbul, Turkey
| | - Onur Bayraktar
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University, School of Medicine, Istanbul, Turkey
| | - Ipek Sapci
- School of Medicine, Acibadem Mehmet Ali Aydinlar University, Istanbul, Turkey
| | - Bilgi Baca
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University, School of Medicine, Istanbul, Turkey
| | - Tayfun Karahasanoglu
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University, School of Medicine, Istanbul, Turkey
| | - Ismail Hamzaoglu
- Department of General Surgery, Acibadem Mehmet Ali Aydinlar University, School of Medicine, Istanbul, Turkey.
| |
Collapse
|
15
|
Ngu JCY, Tsang CBS, Koh DCS. The da Vinci Xi: a review of its capabilities, versatility, and potential role in robotic colorectal surgery. ROBOTIC SURGERY (AUCKLAND) 2017; 4:77-85. [PMID: 30697566 PMCID: PMC6193435 DOI: 10.2147/rsrr.s119317] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The Xi is the latest da Vinci surgical system approved for use in colorectal surgery. With its novel overhead architecture, slimmer boom-mounted arms, extended instrument reach, guided targeting, and integrated auxiliary technology, the Xi manages to address several limitations of earlier models. The versatility of this new system allows it to be implemented in a wide range of colorectal procedures - from complex multiquadrant colectomies to challenging mesorectal dissections in the pelvis. While commonly criticized for its cost and prolonged operative time, robotic colorectal surgery holds the potential for enhanced ergonomics, superior precision, and a reduction in the learning curve involved in training an expert surgeon. This review appraises the existing literature on robotic colorectal surgery while elaborating how the improved capabilities of the Xi serve to usher in a new era of minimally invasive colorectal surgery.
Collapse
Affiliation(s)
| | - Charles Bih-Shiou Tsang
- Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore
- Colorectal Clinic Associates, Mount Elizabeth Novena Specialist Center, Singapore
| | - Dean Chi-Siong Koh
- Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore
- Colorectal Clinic Associates, Mount Elizabeth Novena Specialist Center, Singapore
| |
Collapse
|