1
|
Tao AY, Chen X, Zhang LY, Chen Y, Cao D, Guo ZQ, Chen J. Application of Intraoperative Contrast-Enhanced Ultrasound in the Resection of Brain Tumors. Curr Med Sci 2022; 42:169-176. [PMID: 35122612 DOI: 10.1007/s11596-022-2538-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Accepted: 02/04/2021] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To investigate the value of routine intraoperative ultrasound (IU) and intraoperative contrast-enhanced ultrasound (ICEUS) in the surgical treatment of brain tumors, and to explore the utilization of ICEUS for the removal of the remnants surrounding the resection cavity. METHODS In total, 51 patients who underwent operations from 2012 to 2018 due to different tumors in the brain were included in this study. The clinical data were evaluated retrospectively. IU was performed in all patients, among which 28 patients underwent ICEUS. The effects of IU and ICEUS on tumor resection and recurrence were evaluated. Semiquantitative analysis was performed to compare ICEUS parameters of the brain tumor with those of the surrounding tissue. RESULTS In total, 36 male and 15 female patients were included in this study. The average age was 43 years (range: 14-68 years). The follow-up period was from 7 to 74 months (mean follow-up 32 months). IU was used in all patients, and no lesion was missed. Among them, 28 patients underwent ICEUS. The rate of total removal of the ICEUS group (23/28, 82%) was significantly higher than that of the IU group (11/23, 48%) (P<0.05). The recurrence rate of ICEUS and IU was 18% (5/23), and 22% (5/28), respectively, and the difference did not reach statistical significance (P>0.05). The semiquantitative analysis showed that the intensity and the transit time of microbubbles reaching the lesions were significantly different from the intensity and the transit time of microbubbles reaching the surrounding tissue (P<0.05) and reflected indirectly the volume and the speed of blood perfusion in the lesions was higher than those in the surrounding tissue. CONCLUSION ICEUS is a useful tool in localizing and outlining brain lesions, especially for the resection of the hypervascular lesions in the brain. ICEUS could be more beneficial for identifying the remnants and improving the rate of total removal of these lesions than routine intraoperative ultrasound.
Collapse
Affiliation(s)
- An-Yu Tao
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Xu Chen
- Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
| | - Ling-Yun Zhang
- Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Yong Chen
- Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Dan Cao
- Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Zheng-Qian Guo
- Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Jian Chen
- Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
| |
Collapse
|
2
|
Haimerl M, Brünn K, Poelsterl S, Beyer L, Wiesinger I, Stroszczynski C, Jung EM, Wiggermann P. Quantitative evaluation of real-time maximum liver capacity (LiMAx) and time intensity curve (TIC) analysis in CEUS-based microperfusion. Clin Hemorheol Microcirc 2017; 67:373-382. [DOI: 10.3233/ch-179217] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- M. Haimerl
- Department of Radiology, University Hospital Regensburg, Regensburg, Germany
| | - K Brünn
- Department of Radiology, University Hospital Regensburg, Regensburg, Germany
| | - S. Poelsterl
- Department of Radiology, University Hospital Regensburg, Regensburg, Germany
| | - L.P. Beyer
- Department of Radiology, University Hospital Regensburg, Regensburg, Germany
| | - I. Wiesinger
- Department of Radiology, University Hospital Regensburg, Regensburg, Germany
| | - C. Stroszczynski
- Department of Radiology, University Hospital Regensburg, Regensburg, Germany
| | - E.-M. Jung
- Department of Radiology, University Hospital Regensburg, Regensburg, Germany
| | - P. Wiggermann
- Department of Radiology, University Hospital Regensburg, Regensburg, Germany
| |
Collapse
|
3
|
Kim G, Shim KY, Baik SK. Diagnostic Accuracy of Hepatic Vein Arrival Time Performed with Contrast-Enhanced Ultrasonography for Cirrhosis: A Systematic Review and Meta-Analysis. Gut Liver 2017; 11:93-101. [PMID: 27538445 PMCID: PMC5221866 DOI: 10.5009/gnl16031] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2016] [Revised: 03/07/2016] [Accepted: 03/14/2016] [Indexed: 12/15/2022] Open
Abstract
Background/Aims We identified reports in the literature regarding the diagnostic accuracy of hepatic vein arrival time (HVAT) measured by contrast-enhanced ultrasonography (CEUS) to assess hepatic fibrosis in cirrhosis. Methods The Ovid MEDLINE, Embase, and Cochrane databases were searched for all studies published up to 23 July 2015 that evaluated liver status using CEUS and liver biopsy (LB). The QUADAS-II (quality assessment of diagnostic accuracy studies-II) was applied to assess the internal validity of the diagnostic studies. Selected studies were subjected to a meta-analysis with MetaDisc 1.4 and RevMan 5.3. Results A total of 12 studies including 844 patients with chronic liver disease met our inclusion criteria. The overall summary sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of the HVAT measured by CEUS for the detection of cirrhosis compared to LB were 0.83 (95% confidence interval [CI], 0.77 to 0.89), 0.75 (95% CI, 0.69 to 0.79), 3.45 (95% CI, 1.60 to 7.43), and 0.28 (95% CI, 0.10 to 0.74), respectively. The summary diagnostic odds ratio (random effects model) was 15.23 (95% CI, 3.07 to 75.47), the summary receiver operator characteristics area under the curve was 0.74 (standard error [SE]=0.14), and the index Q was 0.69 (SE=0.11). Conclusions Based on a systematic review, the measurement of HVAT by CEUS exhibited an increased accuracy and correlation for the detection of cirrhosis.
Collapse
Affiliation(s)
- Gaeun Kim
- Department of Nursing, Keimyung University College of Nursing, Daegu, Korea
| | - Kwang Yong Shim
- Department of Internal Medicine, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Korea
| | - Soon Koo Baik
- Department of Internal Medicine, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Korea
| |
Collapse
|
4
|
Morishita K, Hiramoto A, Michishita A, Takagi S, Osuga T, Lim SY, Nakamura K, Sasaki N, Ohta H, Takiguchi M. Washout Ratio in the Hepatic Vein Measured by Contrast-Enhanced Ultrasonography to Distinguish Between Inflammatory and Noninflammatory Hepatic Disorders in Dogs. J Vet Intern Med 2017; 31:770-777. [PMID: 28382699 PMCID: PMC5435075 DOI: 10.1111/jvim.14685] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2016] [Revised: 01/24/2017] [Accepted: 02/02/2017] [Indexed: 02/07/2023] Open
Abstract
Background Perflubutane microbubbles, a second‐generation ultrasound contrast agent, are phagocytized by Kupffer cells. This characteristic may be useful to differentiate diffuse hepatic diseases in dogs. Hypothesis/objectives To determine whether the washout ratio in the hepatic vein (HV) measured by contrast‐enhanced ultrasonography (CEUS) can distinguish between inflammatory and noninflammatory hepatic disorders in dogs. Animals Forty‐one client‐owned dogs with hepatic disorders including 14 with hepatitis, 7 with primary hypoplasia of the portal vein (PHPV), 9 with congenital portosystemic shunt (cPSS), and 11 with other hepatopathy were enrolled. Six dogs without hepatic disease also were evaluated as healthy controls. Methods Dogs with hepatic disorders were prospectively included. Contrast‐enhanced ultrasonography of the HV was performed for 2 minutes. Washout ratio was defined as the attenuation rate from peak intensity to the intensity at the end of the CEUS study. Results Washout ratio in the hepatitis group (median, 18.0%; range, 2.0–37.0%) was significantly lower than that of the PHPV (median, 52.2%; range, 11.5–86.3%), cPSS (median, 60.0%; range, 28.6–77.4%), other hepatopathy (median, 70.5%; range, 26.6–88.4%), and normal (median, 78.0%; range, 60.7–91.7%) groups. The area under the receiver operating characteristic curve for hepatitis was 0.960, with a 95% confidence interval (CI) of 0.853–0.990. Washout ratio ≤37.1% resulted in a sensitivity of 100% (95% CI, 78.5–100%) and specificity of 85.2% (95% CI, 67.5–94.1%) for the prediction of hepatitis. Conclusions and Clinical Importance Washout ratio can distinguish hepatitis from the other noninflammatory disorders with high accuracy. This result might reflect impaired Kupffer cell phagocytosis in dogs with hepatitis.
Collapse
Affiliation(s)
- K Morishita
- Department of Veterinary Clinical Sciences, Veterinary Teaching Hospital, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| | - A Hiramoto
- Laboratory of Veterinary Internal Medicine, Department of Veterinary Clinical Sciences, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| | - A Michishita
- Department of Veterinary Clinical Sciences, Veterinary Teaching Hospital, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| | - S Takagi
- Department of Veterinary Clinical Sciences, Veterinary Teaching Hospital, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| | - T Osuga
- Laboratory of Veterinary Internal Medicine, Department of Veterinary Clinical Sciences, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| | - S Y Lim
- Department of Veterinary Clinical Studies, Faculty of Veterinary Medicine, Universiti Putra Malaysia, Serdang, Selangor, Malaysia
| | - K Nakamura
- Department of Veterinary Clinical Sciences, Veterinary Teaching Hospital, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| | - N Sasaki
- Laboratory of Veterinary Internal Medicine, Department of Veterinary Clinical Sciences, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| | - H Ohta
- Laboratory of Veterinary Internal Medicine, Department of Veterinary Clinical Sciences, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| | - M Takiguchi
- Laboratory of Veterinary Internal Medicine, Department of Veterinary Clinical Sciences, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| |
Collapse
|
5
|
Park J, Cho J, Kwon H, Kang M, Lee S, Roh YH, Kim KW, Lee SW. Liver Function Assessment Using Parenchyma-Specific Contrast-Enhanced Ultrasonography. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:430-437. [PMID: 26610713 DOI: 10.1016/j.ultrasmedbio.2015.08.020] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2015] [Revised: 08/21/2015] [Accepted: 08/31/2015] [Indexed: 06/05/2023]
Abstract
The aim of this study was to assess hepatic functional reserve by analyzing the hepatic parenchyma enhancement curve of parenchyma-specific contrast-enhanced ultrasonography (CEUS). Fifty-two patients with cirrhosis who underwent CEUS and indocyanine green tests (ICG) because of a focal liver lesion were enrolled. We evaluated the hemodynamic-related parameters of the time-intensity curve and compared these findings with the ICG retention rate at 15 min (ICG R15). The correlation between the time from peak to one half (s) and ICG R15 was statistically significant and was relatively proportional to the ICG R15. A cut-off value of 149 s was determined for the time from peak to one half for abnormal ICG R15 (>14). The sensitivity and specificity were 85.7% and 92.3%, respectively, for the detection of abnormal ICG R15. In conclusion, the time from peak to one half of the time-intensity curve of parenchyma-specific CEUS of the liver can be a useful parameter to predict the hepatic reserve in liver cirrhosis.
Collapse
Affiliation(s)
- Jaehyung Park
- Department of Radiology, Dong-A University College of Medicine, Busan, Republic of Korea
| | - Jinhan Cho
- Department of Radiology, Dong-A University College of Medicine, Busan, Republic of Korea.
| | - Heejin Kwon
- Department of Radiology, Dong-A University College of Medicine, Busan, Republic of Korea
| | - Myongjin Kang
- Department of Radiology, Dong-A University College of Medicine, Busan, Republic of Korea
| | - Sangyun Lee
- Department of Radiology, Dong-A University College of Medicine, Busan, Republic of Korea
| | - Young-hoon Roh
- Department of Surgery, Dong-A University College of Medicine, Busan, Republic of Korea
| | - Kwan Woo Kim
- Department of Surgery, Dong-A University College of Medicine, Busan, Republic of Korea
| | - Sung Wook Lee
- Department of Internal Medicine, Dong-A University College of Medicine, Busan, Republic of Korea
| |
Collapse
|