1
|
Fu Y, You Z, Xiao A, Liu L, Zhou W. Electrochemical evaluation of the antioxidant capacity of natural compounds on glassy carbon electrode modified with guanine-, polythionine-, and nitrogen-doped graphene. OPEN CHEM 2020. [DOI: 10.1515/chem-2020-0157] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
AbstractAn electrochemical sensor based on guanine-, polythionine-, and nitrogen-doped graphene modified glassy carbon electrode (G/PTH/NG/GCE) was fabricated and applied for antioxidant capacity evaluation of natural compounds and complexes in electrochemical method since natural sources of active compounds exhibited various antioxidant activities. When the antioxidants existed in the system, the generated hydroxyl radicals were scavenged and the damage to guanine immobilized on the electrode was reduced less resulting in the oxidation peak current increased in square wave voltammetry. After the modifications of polythionine- and nitrogen-doped graphene, the oxidation peak current was improved. The effects of pH, incubation time, and concentrations of guanine and Fe2+ ions on the performances of the electrode were investigated and optimized. The G/PTH/NG/GCE showed good linearity, reproducibility, and storage stability for antioxidant capacity evaluation of ascorbic acid at the optimum conditions. The antioxidant capacities of three flavonoids and three plant extracts were measured using the G/PTH/NG/GCE and DPPH methods. Myricetin showed the highest antioxidant capacity in both electrochemical and DPPH methods. The proposed G/PTH/NG/GCE exhibited easy fabrication procedure, rapid detection time, and low cost for the detection of antioxidant activity for various kinds of samples.
Collapse
Affiliation(s)
- Yafen Fu
- Characteristic Fruit and Vegetable Research Office, Institute of Bast Fiber Crops, Chinese Academy of Agricultural Sciences, Changsha, 410205, People's Republic of China
| | - Zongyi You
- Characteristic Fruit and Vegetable Research Office, Institute of Bast Fiber Crops, Chinese Academy of Agricultural Sciences, Changsha, 410205, People's Republic of China
| | - Aiping Xiao
- Characteristic Fruit and Vegetable Research Office, Institute of Bast Fiber Crops, Chinese Academy of Agricultural Sciences, Changsha, 410205, People's Republic of China
| | - Liangliang Liu
- Characteristic Fruit and Vegetable Research Office, Institute of Bast Fiber Crops, Chinese Academy of Agricultural Sciences, Changsha, 410205, People's Republic of China
| | - Weien Zhou
- Hunan Fangsheng Pharmaceutical Co., Ltd, Changsha, 410205, People's Republic of China
| |
Collapse
|
2
|
Brainina K, Stozhko N, Bukharinova M, Vikulova E. Nanomaterials: Electrochemical Properties and Application in Sensors. PHYSICAL SCIENCES REVIEWS 2018. [DOI: 10.1515/psr-2018-8050] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Abstract
The unique properties of nanoparticles make them an extremely valuable modifying material, being used in electrochemical sensors. The features of nanoparticles affect the kinetics and thermodynamics of electrode processes of both nanoparticles and redox reactions occurring on their surface. The paper describes theoretical background and experimental studies of these processes. During the transition from macro- to micro- and nanostructures, the analytical characteristics of sensors modify. These features of metal nanoparticles are related to their size and energy effects, which affects the analytical characteristics of developed sensors. Modification of the macroelectrode with nanoparticles and other nanomaterials reduces the detection limit and improves the degree of sensitivity and selectivity of measurements. The use of nanoparticles as transducers, catalytic constituents, parts of electrochemical sensors for antioxidant detection, adsorbents, analyte transporters, and labels in electrochemical immunosensors and signal-generating elements is described.
Collapse
|
3
|
Taebi S, Keyhanfar M, Noorbakhsh A. A novel method for sensitive, low-cost and portable detection of hepatitis B surface antigen using a personal glucose meter. J Immunol Methods 2018; 458:26-32. [PMID: 29654816 DOI: 10.1016/j.jim.2018.04.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2017] [Revised: 03/09/2018] [Accepted: 04/04/2018] [Indexed: 10/25/2022]
Abstract
Hepatitis B virus (HBV) infection is the major public health problem leading cause of death worldwide. The most important diagnostic marker for this infection is hepatitis B surface antigen (HBsAg). In this study, a novel, inexpensive, portable and sensitive ELISA method was designed and investigated for diagnosis of HBsAg based on the functionalized Fe3O4 and Al2O3 nanoparticles, with the strategy for detecting the concentration of glucose using a cheap and accessible personal glucose meter (PGM). The ELISA system was constructed using hepatitis B antibody against HBsAg immobilized on streptavidin coated magnetic iron oxide particles (S-Fe3O4) as the capture antibody (Ab1). In addition, another hepatitis B antibody against different epitope of HBsAg (Ab2) and glucoamylase both were immobilized on Al2O3 nanoparticles. After formation of the sandwich immune complex between Ab1 and Ab2 immobilized on S-Fe3O4 and Al2O3 NPs, respectively, through HBsAg, starch was converted into glucose using glucoamylase. Then, the glucose concentration was measured using PGM. The concentration of HBsAg was calculated based on the linear relation between the concentrations of HBsAg and glucose. Under optimal conditions, this assay showed detection limit values of 0.3 to 0.4 ng ml-1 for "ay" and "ad" subtypes of HBsAg, respectively. The results indicate that the designed assay is comparable to the commercial kits in terms of sensitivity, on-site, specificity, cost, simplicity, portability and reproducibility. The presented method can be used in disadvantaged areas of the world and blood transfusion centers. To the best of our knowledge, this is the first report of using PGMs for HBSAg detection.
Collapse
Affiliation(s)
- Saeed Taebi
- Department of Biotechnology, Faculty of Advanced Sciences and Technologies, University of Isfahan, Isfahan 81746-73441, Iran
| | - Mehrnaz Keyhanfar
- Department of Biotechnology, Faculty of Advanced Sciences and Technologies, University of Isfahan, Isfahan 81746-73441, Iran.
| | - Abdollah Noorbakhsh
- Department of Nanotechnology Engineering, Faculty of Advanced Sciences and Technologies, University of Isfahan, Isfahan 81746-73441, Iran
| |
Collapse
|
4
|
Alizadeh N, Hallaj R, Salimi A. A highly sensitive electrochemical immunosensor for hepatitis B virus surface antigen detection based on Hemin/G-quadruplex horseradish peroxidase-mimicking DNAzyme-signal amplification. Biosens Bioelectron 2017; 94:184-192. [PMID: 28284078 DOI: 10.1016/j.bios.2017.02.039] [Citation(s) in RCA: 77] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2016] [Revised: 02/21/2017] [Accepted: 02/23/2017] [Indexed: 01/16/2023]
Abstract
Here we prepared an electrochemical immunosensor employing Au sheet as working electrode, Fe3O4 magnetic nanoparticles (MNPs) as supporting matrix and hemin/G-quadruplex DNAzyme as signal amplifier for determination of hepatitis B virus surface antigen (HBsAg). First, the primary antibody of HBs (Ab1) was immobilized on the surface of the carboxyl-modified MNPs. Then, the assembly of antibody and alkylthiol/G-quadruplex DNA/hemin on gold nanoparticles was used as bio-bar-coded nanoparticle probe. Protein target was sandwiched between the primary antibody of HBs (Ab1) immobilized on the MNPs and hemin bio-bar-coded AuNPs probe labeled antibody (Ab2). Hemin/G-quadruplex structure as HRP mimicking-DNAzyme significantly improved the catalytic reduction of H2O2 by oxidation of methylene blue (MB). Square wave voltammetry signals of MB provided quantitative measurements of HBsAg with a linear concentration range of 0.3-1000 pgmL-1 and detection limit of 0.19 pgmL-1. Due to efficient catalytic activity of HRP mimicking-DNAzyme, the proposed immunosensor exhibited high sensitivity and it holds great promise for clinical application and provides a new platform for immunosensor development and fast disease diagnosis.
Collapse
Affiliation(s)
- Negar Alizadeh
- Department of Chemistry, University of Kurdistan, 66177-15175 Sanandaj, Iran
| | - Rahman Hallaj
- Department of Chemistry, University of Kurdistan, 66177-15175 Sanandaj, Iran; Research Center for Nanotechnology, University of Kurdistan, 66177-15175 Sanandaj, Iran.
| | - Abdollah Salimi
- Department of Chemistry, University of Kurdistan, 66177-15175 Sanandaj, Iran; Research Center for Nanotechnology, University of Kurdistan, 66177-15175 Sanandaj, Iran.
| |
Collapse
|
5
|
Design of dual working electrodes for concentration process in metalloimmunoassay. Biomed Microdevices 2016; 18:86. [PMID: 27572238 DOI: 10.1007/s10544-016-0114-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Electrochemical immunosensing, particularly through a metalloimmunoassay, is a promising approach for development of point-of-care (POC) diagnostics devices. This study investigated the structure of dual working electrodes (W1 and W2), used in a silver nanoparticles-labeled sandwich-type immunoassay and silver concentration process, paying special attention to the position of W1 relative to W2. The new structures of the dual working electrodes were fabricated for efficient silver concentration and evaluated experimentally, which showed that the duration of prereduction before current measurement decreased from 480 s to 300 s by transforming the position of W1 from 1 line to 2 lines or 6 parts. The experimental results were also compared with numerical simulations based on three-dimensional diffusion, and the prereduction step almost followed the three-dimensional diffusion equation. Using numerical simulations, the ideal structures of dual working electrodes were designed based on relationships between the structures and duration of prereduction or the LOD. In the case of 36 lines at an area ratio of W1 to W1 + W2 of 1 to 10, the prereduction duration decreased to 96 s. The dual working electrodes designed in this study promise to shorten the total analysis time and lower the LOD for POC diagnostics.
Collapse
|
6
|
Kakhki RM. Recent developments on the modification of graphite electrodes with nanoparticles. RUSS J APPL CHEM+ 2016. [DOI: 10.1134/s10704272160030204] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
7
|
Gold nanoparticles conjugates-amplified aptamer immunosensing screen-printed carbon electrode strips for thrombin detection. Biosens Bioelectron 2014; 61:336-43. [PMID: 24912033 DOI: 10.1016/j.bios.2014.05.007] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2014] [Revised: 05/01/2014] [Accepted: 05/02/2014] [Indexed: 12/15/2022]
Abstract
Thrombin plays the role in cardiovascular diseases and regulates many processes in inflammation and could be a feature of many pathological conditions, including the thromboembolic disease, cancer and neurodegenerative diseases. An ultrasensitive and amplified electrochemical sandwich assay using screen-printed carbon electrode (SPCE) strips for thrombin detection was established in this study. The conductivity and sensing performance of the carbon electrodes were enhanced by using gold nanoparticles (AuNPs). The aptamer addressed on the strips was used as a primary probe to capture thrombin in the detected samples. An amplifier was invented for recognizing thrombin captured on the SPCE, which is the multiple molecules of anti-thrombin antibody (Ab) and horseradish peroxidase (HRP) co-modified AuNPs (AuNPs/Ab-HRP). Hydrogen peroxide was used as the substrate for HRP and then the response current (RC) could be detected. The optimization of these AuNPs conjugates-amplified aptamer immunosensing SPCE strips was conducted for thrombin detection. The detection sensitivity showed a linear relation between RC and thrombin concentration in the range of 10 pM-100 nM, and limit of detection (LOD) was 1.5 pM. The fabricated AuNPs/Ab-HRP-amplified aptamer immunosensing SPCE strips were further used to detect thrombin in human serum with a linear range of 100 pM-100 nM. This study provided the promising SPCE strips with highly sensitive and rapid detection for thrombin by the electrochemical aptasensor combined with AuNPs conjugates for amplifying the detection signal.
Collapse
|
8
|
Nourani S, Ghourchian H, Boutorabi SM. Magnetic nanoparticle-based immunosensor for electrochemical detection of hepatitis B surface antigen. Anal Biochem 2013; 441:1-7. [PMID: 23831477 DOI: 10.1016/j.ab.2013.06.011] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2013] [Revised: 06/18/2013] [Accepted: 06/22/2013] [Indexed: 12/11/2022]
Abstract
An electrochemical immunosensor was developed for the detection of hepatitis B surface antigen (HBsAg). The biotinylated hepatitis B surface antibody was immobilized on streptavidin magnetic nanoparticles and used for targeting the HBsAg. By the addition of horseradish peroxidase conjugated with secondary antibody (HRP-HBsAb), a sandwich-type immunoassay format was formed. Aminophenol as substrate for conjugated HRP was enzymatically changed into 3-aminophenoxazone (3-APZ). This electroactive enzymatic production (3-APZ) was transferred into an electrochemical cell and monitored by cyclic voltammetry. Under optimal conditions, the cathodic current response of 3-APZ, which was proportional to the HBsAg concentration, was measured by a glassy carbon electrode. The immunosensor response was linear toward HBsAg in the concentration range from 0.001 to 0.015 ng/ml with a detection limit of 0.9 pg/ml at a signal/noise ratio of 3.
Collapse
Affiliation(s)
- Sara Nourani
- Laboratory of Microanalysis, Institute of Biochemistry and Biophysics, University of Tehran, Tehran, Iran
| | | | | |
Collapse
|
9
|
Cao X, Wang N, Jia S, Guo L, Li K. Bimetallic AuPt nanochains: Synthesis and their application in electrochemical immunosensor for the detection of carcinoembryonic antigen. Biosens Bioelectron 2013; 39:226-30. [DOI: 10.1016/j.bios.2012.07.046] [Citation(s) in RCA: 98] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2012] [Revised: 07/20/2012] [Accepted: 07/23/2012] [Indexed: 01/06/2023]
|
10
|
Ghosh SK, Kundu T, Sain A. From chemosensing in microorganisms to practical biosensors. PHYSICAL REVIEW. E, STATISTICAL, NONLINEAR, AND SOFT MATTER PHYSICS 2012; 86:051910. [PMID: 23214817 DOI: 10.1103/physreve.86.051910] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2012] [Revised: 09/24/2012] [Indexed: 06/01/2023]
Abstract
Microorganisms like bacteria can sense concentrations of chemoattractants in their medium very accurately. They achieve this through interaction between the receptors on their cell surfaces and chemoattractant molecules (like sugar). Physical processes like diffusion set some limits on the accuracy of detection, which was discussed by Berg and Purcell in the late seventies. We re-examine their work in order to assess what insight it may offer for making efficient, practical biosensors. We model the functioning of a typical biosensor as a reaction-diffusion process in a confined geometry. Using available data first we characterize the system by estimating the kinetic constants for the binding and unbinding reactions between the chemoattractants and the receptors. Then we compute the binding flux for this system, which Berg and Purcell had discussed. Unlike in microorganisms where the interval between successive measurements determines the efficiency of the nutrient searching process, it turns out that biosensors depend on long time properties like signal saturation time, which we study in detail. We also develop a mean field description of the kinetics of the system.
Collapse
Affiliation(s)
- Surya K Ghosh
- Department of Physics, Indian Institute of Technology, Bombay, Powai, Mumbai 400 076, India
| | | | | |
Collapse
|
11
|
Cao X, Ye Y, Liu S. Gold nanoparticle-based signal amplification for biosensing. Anal Biochem 2011; 417:1-16. [DOI: 10.1016/j.ab.2011.05.027] [Citation(s) in RCA: 301] [Impact Index Per Article: 21.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2011] [Revised: 05/09/2011] [Accepted: 05/17/2011] [Indexed: 12/11/2022]
|
12
|
Nanoparticle-based electrochemical detection in conventional and miniaturized systems and their bioanalytical applications: A review. Anal Chim Acta 2011; 690:10-25. [DOI: 10.1016/j.aca.2011.01.054] [Citation(s) in RCA: 109] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2010] [Revised: 01/26/2011] [Accepted: 01/27/2011] [Indexed: 01/04/2023]
|
13
|
Heinze BC, Yoon JY. Nanoparticle immunoagglutination Rayleigh scatter assay to complement microparticle immunoagglutination Mie scatter assay in a microfluidic device. Colloids Surf B Biointerfaces 2011; 85:168-73. [PMID: 21411297 DOI: 10.1016/j.colsurfb.2011.02.024] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2010] [Revised: 02/15/2011] [Accepted: 02/15/2011] [Indexed: 10/18/2022]
Abstract
In this work, particle immunoagglutination assays for pathogen detection, utilizing light scattering measurements at a fixed angle from incident light delivery, are explored in both Rayleigh and Mie scatter regimes through scatter intensity simulations and compared to experimental results. The average size of immunoagglutinated particles obtained from microscope images correspond to the particle size parameter from simulations. Mie scatter measurements yield a greater signal increase with increasing pathogen concentration than Rayleigh scatter measurements, but with a non-monotonic relationship that is not observed in the Rayleigh scatter regime. These two similar yet distinctly different sources of information could easily be integrated into a single device through fabrication of a simple microfluidic device containing two y-channels, each for performing the respective light scattering measurement. Escherichia coli was used as a representative target, and detected in a microfluidic device down to a concentration of 1 colony forming units (CFU) per mL.
Collapse
Affiliation(s)
- Brian C Heinze
- Department of Agricultural and Biosystems Engineering, The University of Arizona, Tucson, AZ 85721-0038, USA
| | | |
Collapse
|
14
|
Label-free immunosensing of microcystin-LR using a gold electrode modified with gold nanoparticles. Mikrochim Acta 2011. [DOI: 10.1007/s00604-011-0557-8] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
15
|
Cao Q, Zhao H, Yang Y, He Y, Ding N, Wang J, Wu Z, Xiang K, Wang G. Electrochemical immunosensor for casein based on gold nanoparticles and poly(L-Arginine)/multi-walled carbon nanotubes composite film functionalized interface. Biosens Bioelectron 2011; 26:3469-74. [PMID: 21334187 DOI: 10.1016/j.bios.2011.01.027] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2010] [Revised: 01/17/2011] [Accepted: 01/20/2011] [Indexed: 11/17/2022]
Abstract
In this paper, a novel electrochemical immunosensor for the determination of casein based on gold nanoparticles and poly(L-Arginine)/multi-walled carbon nanotubes (P-L-Arg/MWCNTs) composite film was proposed. The P-L-Arg/MWCNTs composite film was used to modify glassy carbon electrode (GCE) to fabricate P-L-Arg/MWCNTs/GCE through electropolymerization of L-Arginine on MWCNTs/GCE. Gold nanoparticles were adsorbed on the modified electrode to immobilize the casein antibody and to construct the immunosensor. The stepwise assembly process of the immunosensor was characterized by cyclic voltammetry and differential pulse voltammetry. Results demonstrated that the peak currents of [Fe(CN)(6)](3-/4-) redox pair decreased due to the formation of antibody-antigen complex on the modified electrode. The optimization of the adsorption time of gold nanoparticles, the pH of supporting electrolyte and the incubation time were investigated in details. Under optimal conditions, the peak currents obtained by DPV decreased linearly with the increasing casein concentrations in the range from 1 × 10(-7) to 1 × 10(-5) g mL(-1) with a linear coefficiency of 0.993. This electrochemical immunoassay has a low detection limit of 5 × 10(-8) g mL(-1) and was successfully applied to the determination of casein in cheese samples.
Collapse
Affiliation(s)
- Qian Cao
- College of Chemistry and Chemical Engineering, Graduate University of Chinese Academy of Sciences, 19A YuQuan Road, Beijing 100049, China
| | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Zhong Z, Wu W, Wang D, Wang D, Shan J, Qing Y, Zhang Z. Nanogold-enwrapped graphene nanocomposites as trace labels for sensitivity enhancement of electrochemical immunosensors in clinical immunoassays: Carcinoembryonic antigen as a model. Biosens Bioelectron 2010; 25:2379-83. [DOI: 10.1016/j.bios.2010.03.009] [Citation(s) in RCA: 144] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2010] [Revised: 03/03/2010] [Accepted: 03/03/2010] [Indexed: 10/19/2022]
|
17
|
Glucose biosensor based on graphite electrodes modified with glucose oxidase and colloidal gold nanoparticles. Mikrochim Acta 2010. [DOI: 10.1007/s00604-009-0270-z] [Citation(s) in RCA: 74] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
18
|
A disposable immunosensor based on gold colloid modified chitosan nanoparticles-entrapped carbon paste electrode. Mikrochim Acta 2009. [DOI: 10.1007/s00604-009-0254-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
19
|
Electrochemical sensor for heparin based on a poly(thionine) modified glassy carbon electrode. Mikrochim Acta 2009. [DOI: 10.1007/s00604-009-0240-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|