1
|
Phonklam K, Sriwimol W, Thuptimdang W, Phairatana T. Disposable label-free electrochemical immunosensor based on gold nanoparticles-Prussian blue for neutrophil gelatinase-associated lipocalin detection in urine samples. Talanta 2024; 274:125960. [PMID: 38555767 DOI: 10.1016/j.talanta.2024.125960] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 03/17/2024] [Accepted: 03/19/2024] [Indexed: 04/02/2024]
Abstract
Neutrophil gelatinase-associated lipocalin (NGAL) is a remarkable biomarker for assessing acute kidney injury. In this study, we developed a novel label-free NGAL electrochemical immunosensor based on gold nanoparticles (AuNPs) and Prussian blue (PB) without an external mediator. The AuNPs-PB based immunosensor was fabricated on a custom gold-electrode (AuE)-based polypropylene (PP) substrate. We systematically assessed and optimized key experimental parameters, including the process of AuNPs-PB electrodeposition, antibody concentration, and incubation time. The immunosensor response toward NGAL was determined using differential pulse voltammetry, where the decrease in the oxidation current response of the PB redox probe correlating with the increase in NGAL concentration. Our results demonstrated that the synergistic benefits of both AuNPs and PB significantly improved electrochemical activity for NGAL detection and provided a highly stable sensor across a range of pH values. The label-free immunosensor exhibited two linear ranges: 0.10-1.40 ng mL-1 and 1.40-25.0 ng mL-1, with a low detection limit of 0.094 ng mL-1. The developed NGAL immunosensor displayed high selectivity and excellent reproducibility. Furthermore, NGAL detection was completed within 30 min and the immunosensor exhibited storage stability for six weeks. Notably, NGAL levels determined in human urine samples using this developed label-free immunosensor showed good agreement with the results obtained from the enzyme-linked immunosorbent assay. This novel label-free NGAL immunosensor provides great potential in developing NGAL point-of-care testing applications.
Collapse
Affiliation(s)
- Kewarin Phonklam
- Department of Biomedical Sciences and Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Wilaiwan Sriwimol
- Department of Pathology, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Wanwara Thuptimdang
- Department of Biomedical Sciences and Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Institute of Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Tonghathai Phairatana
- Department of Biomedical Sciences and Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Institute of Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Medical Biosensor Laboratory, Medical Science Research and Innovation Institute, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.
| |
Collapse
|
2
|
Ashraf G, Aziz A, Iftikhar T, Zhong ZT, Asif M, Chen W. The Roadmap of Graphene-Based Sensors: Electrochemical Methods for Bioanalytical Applications. BIOSENSORS 2022; 12:1183. [PMID: 36551150 PMCID: PMC9775289 DOI: 10.3390/bios12121183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 12/07/2022] [Accepted: 12/16/2022] [Indexed: 06/17/2023]
Abstract
Graphene (GR) has engrossed immense research attention as an emerging carbon material owing to its enthralling electrochemical (EC) and physical properties. Herein, we debate the role of GR-based nanomaterials (NMs) in refining EC sensing performance toward bioanalytes detection. Following the introduction, we briefly discuss the GR fabrication, properties, application as electrode materials, the principle of EC sensing system, and the importance of bioanalytes detection in early disease diagnosis. Along with the brief description of GR-derivatives, simulation, and doping, classification of GR-based EC sensors such as cancer biomarkers, neurotransmitters, DNA sensors, immunosensors, and various other bioanalytes detection is provided. The working mechanism of topical GR-based EC sensors, advantages, and real-time analysis of these along with details of analytical merit of figures for EC sensors are discussed. Last, we have concluded the review by providing some suggestions to overcome the existing downsides of GR-based sensors and future outlook. The advancement of electrochemistry, nanotechnology, and point-of-care (POC) devices could offer the next generation of precise, sensitive, and reliable EC sensors.
Collapse
Affiliation(s)
- Ghazala Ashraf
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Ayesha Aziz
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Tayyaba Iftikhar
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Zi-Tao Zhong
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Muhammad Asif
- Hubei Key Laboratory of Plasma Chemistry and Advanced Materials, School of Materials Science and Engineering, Wuhan Institute of Technology, Wuhan 430205, China
| | - Wei Chen
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| |
Collapse
|
3
|
Kapoor A, Varnika, Pratibha, Rajput JK, Singh D, Kumar N, Jigyasa. Bi2O3 @MWCNT@g-C3N4 Ternary Nanocomposite for the Efficient Electrochemical Determination of Riboflavin in Pharmaceutical Samples. J Food Compost Anal 2022. [DOI: 10.1016/j.jfca.2022.104792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
|
4
|
Chakraborty T, Das M, Lin CY, Lei KF, Kao CH. Highly sensitive and selective electrochemical detection of lipocalin 2 by NiO nanoparticles/perovskite CeCuOx based immunosensor to diagnose renal failure. Anal Chim Acta 2022; 1205:339754. [DOI: 10.1016/j.aca.2022.339754] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 03/14/2022] [Accepted: 03/20/2022] [Indexed: 11/01/2022]
|
5
|
Wang WJ, Chou MC, Lee YJ, Hsu WL, Wang GJ. A simple electrochemical immunosensor based on a gold nanoparticle monolayer electrode for neutrophil gelatinase-associated lipocalin detection. Talanta 2022; 246:123530. [DOI: 10.1016/j.talanta.2022.123530] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Revised: 04/23/2022] [Accepted: 05/04/2022] [Indexed: 01/23/2023]
|
6
|
Merlin JPJ, Li X. Role of Nanotechnology and Their Perspectives in the Treatment of Kidney Diseases. Front Genet 2022; 12:817974. [PMID: 35069707 PMCID: PMC8766413 DOI: 10.3389/fgene.2021.817974] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Accepted: 12/06/2021] [Indexed: 12/12/2022] Open
Abstract
Nanoparticles (NPs) are differing in particle size, charge, shape, and compatibility of targeting ligands, which are linked to improved pharmacologic characteristics, targetability, and bioavailability. Researchers are now tasked with developing a solution for enhanced renal treatment that is free of side effects and delivers the medicine to the active spot. A growing number of nano-based medication delivery devices are being used to treat renal disorders. Kidney disease management and treatment are currently causing a substantial global burden. Renal problems are multistep processes involving the accumulation of a wide range of molecular and genetic alterations that have been related to a variety of kidney diseases. Renal filtration is a key channel for drug elimination in the kidney, as well as a burgeoning topic of nanomedicine. Although the use of nanotechnology in the treatment of renal illnesses is still in its early phases, it offers a lot of potentials. In this review, we summarized the properties of the kidney and characteristics of drug delivery systems, which affect a drug’s ability should focus on the kidney and highlight the possibilities, problems, and opportunities.
Collapse
Affiliation(s)
- J P Jose Merlin
- Department of Internal Medicine, Mayo Clinic, Rochester, MN, United States
| | - Xiaogang Li
- Department of Internal Medicine, Mayo Clinic, Rochester, MN, United States.,Department of Biochemistry and Molecular Biology, Mayo Clinic, Rochester, MN, United States
| |
Collapse
|
7
|
Yin M, Nie Y, Liu H, Liu L, Tang L, Dong Y, Hu C, Wang H. Development of a europium nanoparticles lateral flow immunoassay for NGAL detection in urine and diagnosis of acute kidney injury. BMC Nephrol 2022; 23:30. [PMID: 35031018 PMCID: PMC8758895 DOI: 10.1186/s12882-021-02493-w] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 08/02/2021] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND AKI is related to severe adverse outcomes and mortality with Coronavirus Disease 2019 (COVID-19) patients, that early diagnosed and intervened is imperative. Neutrophil gelatinase-associated lipocalin (NGAL) is one of the most promising biomarkers for detection of acute kidney injury (AKI), but current detection methods are inadequacy, so more rapid, convenient and accuracy methods are needed to detect NGAL for early diagnosis of AKI. Herein, we established a rapid, reliable and accuracy lateral flow immunoassay (LFIA) based on europium nanoparticles (EU-NPS) for the detection of NGAL in human urine specimens. METHODS A double-antibody sandwich immunofluorescent assay using europium doped nanoparticles was employed and the NGAL monoclonal antibodies (MAbs) conjugate as labels were generated by optimizing electric fusion parameters. Eighty-three urine samples were used to evaluate the clinical application efficiency of this method. RESULTS The quantitative detection range of NGAL in AKI was 1-3000 ng/mL, and the detection sensitization was 0.36 ng/mL. The coefficient of variation (CV) of intra-assay and inter-assay were 2.57-4.98 % and 4.11-7.83 %, respectively. Meanwhile, the correlation coefficient between europium nanoparticles-based lateral fluorescence immunoassays (EU-NPS-LFIA) and ARCHITECT analyzer was significant (R2 = 0.9829, n = 83, p < 0.01). CONCLUSIONS Thus, a faster and easier operation quantitative assay of NGAL for AKI has been established, which is very important and meaningful to diagnose the early AKI, suggesting that the assay can provide an early warning of final outcome of disease.
Collapse
Affiliation(s)
- Moli Yin
- Jilin Collaborative Innovation Center for Antibody Engineering, Jilin Medical University, 132013, Jilin, PR China
| | - Yuanwang Nie
- Academy of laboratory, Jilin Medical University, 132013, Jilin, PR China
| | - Hao Liu
- Academy of laboratory, Jilin Medical University, 132013, Jilin, PR China
| | - Lei Liu
- Jilin Collaborative Innovation Center for Antibody Engineering, Jilin Medical University, 132013, Jilin, PR China
| | - Lu Tang
- Jilin Collaborative Innovation Center for Antibody Engineering, Jilin Medical University, 132013, Jilin, PR China
| | - Yuan Dong
- Academy of laboratory, Jilin Medical University, 132013, Jilin, PR China
| | - Chuanmin Hu
- Jilin Collaborative Innovation Center for Antibody Engineering, Jilin Medical University, 132013, Jilin, PR China
| | - Huiyan Wang
- Jilin Collaborative Innovation Center for Antibody Engineering, Jilin Medical University, 132013, Jilin, PR China.
| |
Collapse
|
8
|
A novel label-free electrochemical immunesensor for ultrasensitive detection of LT toxin using prussian blue@gold nanoparticles composite as a signal amplification. Bioelectrochemistry 2021; 142:107887. [PMID: 34298495 DOI: 10.1016/j.bioelechem.2021.107887] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Revised: 06/28/2021] [Accepted: 07/12/2021] [Indexed: 01/05/2023]
Abstract
In the current study, a novel electrochemical label-free immunosensor is proposed for sensitive detection of heat-labile enterotoxin (LT) from Escherichia coli. Firstly, a glassy carbon electrode (GCE) was modified by a mixture containing reduced graphene oxide/room temperature ionic liquid (rGO/RTIL) composite. Then, simultaneous electrodeposition of prussian blue and gold nanoparticles led to formation of prussian blue@gold nanoparticles (PB@GNPs) composite on the electrode surface. The modified electrode was characterized by field emission scanning electron microscopy (FE-SEM), energy dispersive spectroscopy (EDS), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques. After immobilization of anti-LT and blocking the unreacted sites with BSA (bovine serum albumin), the analytical performance of the proposed immunosensor was evaluated under optimal conditions (i.e. optimal pH, incubation time and temperature of incubation). Square wave voltammetry (SWV) was used to determine different concentrations of the LT antigen. The linear dynamic range of the proposed immunosensor was from 0.01 to 50 µg/mL and the detection limit of the immunosensor was found to be 0.0023 µg/mL. An acceptable selectivity in the real sample, long-term stability and goodreproducibility made the fabricated immunosensor a good candidate for detecting LT.
Collapse
|
9
|
Kurup CP, Mohd-Naim NF, Tlili C, Ahmed MU. A Highly Sensitive Label-free Aptasensor Based on Gold Nanourchins and Carbon Nanohorns for the Detection of Lipocalin-2 (LCN-2). ANAL SCI 2021; 37:825-831. [PMID: 33041307 DOI: 10.2116/analsci.20p303] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A synergistic nanocomposite film composed of gold nanourchins (AuNU), oxidised carbon nanohorns (CNH), and chitosan functioned as an electrode modifier in the fabrication of the sensitive lipocalin-2 (LCN-2) aptasensor. The AuNUs/CNH/CS composite increased the surface area and thereby amplified the signal transduction. The amine-terminated LCN-2 aptamer was immobilised through the amide bond formed between the carboxyl group of polyglutamic acid (PGA) and the amine group of aptamer. Interaction of LCN-2 with the aptamer caused conformational changes in the structure of the aptamer. This generated higher conductivity, resulting in increased DPV peak current. The DPV signal increased with increasing concentration of LCN-2, and the change in signal was used for quantitative detection. The proposed aptasensor was able to detect LCN-2 in the linear range of 0.1 - 100.0 pg mL-1, with a low detection limit of 10 fg mL-1. The aptasensor showed high sensitivity, selectivity, reproducibility, and was able to detect LCN-2 in serum samples.
Collapse
Affiliation(s)
- Chitra Padmakumari Kurup
- Biosensors and Nanobiotechnology Laboratory, Integrated Science Building, Faculty of Science, Universiti Brunei Darussalam
| | | | - Chaker Tlili
- Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences
| | - Minhaz Uddin Ahmed
- Biosensors and Nanobiotechnology Laboratory, Integrated Science Building, Faculty of Science, Universiti Brunei Darussalam
| |
Collapse
|
10
|
Advanced sensitivity amplification strategies for voltammetric immunosensors of tumor marker: State of the art. Biosens Bioelectron 2021; 178:113021. [DOI: 10.1016/j.bios.2021.113021] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Revised: 11/27/2020] [Accepted: 01/18/2021] [Indexed: 12/24/2022]
|
11
|
Majdoub M, Anfar Z, Amedlous A. Emerging Chemical Functionalization of g-C 3N 4: Covalent/Noncovalent Modifications and Applications. ACS NANO 2020; 14:12390-12469. [PMID: 33052050 DOI: 10.1021/acsnano.0c06116] [Citation(s) in RCA: 139] [Impact Index Per Article: 27.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Atomically 2D thin-layered structures, such as graphene nanosheets, graphitic carbon nitride nanosheets (g-C3N4), hexagonal boron nitride, and transition metal dichalcogenides are emerging as fascinating materials for a good array of domains owing to their rare physicochemical characteristics. In particular, graphitic carbon nitride has turned into a hot subject in the scientific community due to numerous qualities such as simple preparation, electrochemical properties, high adsorption capacity, good photochemical properties, thermal stability, and acid-alkali chemical resistance, etc. Basically, g-C3N4 is considered as a polymeric material consisting of N and C atoms forming a tri-s-triazine network connected by planar amino groups. In comparison with most C-based materials, g-C3N4 possesses electron-rich characteristics, basic moieties, and hydrogen-bonding groups owing to the presence of hydrogen and nitrogen atoms; therefore, it is taken into account as an interesting nominee to further complement carbon in applications of functional materials. Nevertheless, g-C3N4 has some intrinsic limitations and drawbacks mainly related to a relatively poor specific surface area, rapid charge recombination, a limited light absorption range, and a poor dispersibility in both aqueous and organic mediums. To overcome these shortcomings, numerous chemical modification approaches have been conducted with the aim of expanding the range of application of g-C3N4 and enhancing its properties. In the current review, the comprehensive survey is conducted on g-C3N4 chemical functionalization strategies including covalent and noncovalent approaches. Covalent approaches consist of establishing covalent linkage between the g-C3N4 structure and the chemical modifier such as oxidation/carboxylation, amidation, polymer grafting, etc., whereas the noncovalent approaches mainly consist of physical bonding and intermolecular interaction such as van der Waals interactions, electrostatic interactions, π-π interactions, and so on. Furthermore, the preparation, characterization, and diverse applications of functionalized g-C3N4 in various domains are described and recapped. We believe that this work will inspire scientists and readers to conduct research with the aim of exploring other functionalization strategies for this material in numerous applications.
Collapse
Affiliation(s)
- Mohammed Majdoub
- Laboratory of Materials, Catalysis & Valorization of Natural Resources, Hassan II University, Casablanca 20000, Morocco
| | - Zakaria Anfar
- Laboratory of Materials & Environment, Ibn Zohr University, Agadir 80000, Morocco
- Institute of Materials Science of Mulhouse, Haute Alsace University, Mulhouse 68100, France
- Strasbourg University, Strasbourg 67081, France
| | - Abdallah Amedlous
- Laboratory of Materials, Catalysis & Valorization of Natural Resources, Hassan II University, Casablanca 20000, Morocco
| |
Collapse
|
12
|
Cross-linkage urease nanoparticles: a high-efficiency signal-generation tag for portable pH meter-based electrochemical immunoassay of lipocalin-2 protein diagnostics. Mikrochim Acta 2020; 187:485. [DOI: 10.1007/s00604-020-04466-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 07/25/2020] [Indexed: 12/20/2022]
|
13
|
Ma Y, Cai F, Li Y, Chen J, Han F, Lin W. A review of the application of nanoparticles in the diagnosis and treatment of chronic kidney disease. Bioact Mater 2020; 5:732-743. [PMID: 32596555 PMCID: PMC7303522 DOI: 10.1016/j.bioactmat.2020.05.002] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Revised: 05/14/2020] [Accepted: 05/18/2020] [Indexed: 02/07/2023] Open
Abstract
Chronic kidney disease (CKD) poses a great burden to global public health as current therapies are generally ineffective. Early detection and effective therapy are crucial for the future prevention and progression of CKD. Nanoparticles (NPs) vary by particle size, charge, shape and the density of targeting ligands and are associated with enhancement of the pharmacokinetic properties, targetability, or the bioavailability of drugs. Thus, the emergence of NPs in medicine has provided novel solutions to the potential diagnosis and treatment of CKD. This review describes the current experimental research, clinical applications of NPs, the current challenges, and upcoming opportunities in the diagnosis and treatment of CKD.
Collapse
Affiliation(s)
- Yanhong Ma
- Kidney Disease Center, The First Affiliated Hospital, Zhejiang University School of Medicine, Institute of Nephrology, Zhejiang University, Key Laboratory of Kidney Disease Prevention and Control Technology, Zhejiang Province, Hangzhou, 310003, China
| | - Fanghao Cai
- Kidney Disease Center, The First Affiliated Hospital, Zhejiang University School of Medicine, Institute of Nephrology, Zhejiang University, Key Laboratory of Kidney Disease Prevention and Control Technology, Zhejiang Province, Hangzhou, 310003, China
| | - Yangyang Li
- Institute of Translational Medicine, Zhejiang University School of Medicine, Hangzhou, 310029, China
| | - Jianghua Chen
- Kidney Disease Center, The First Affiliated Hospital, Zhejiang University School of Medicine, Institute of Nephrology, Zhejiang University, Key Laboratory of Kidney Disease Prevention and Control Technology, Zhejiang Province, Hangzhou, 310003, China
| | - Fei Han
- Kidney Disease Center, The First Affiliated Hospital, Zhejiang University School of Medicine, Institute of Nephrology, Zhejiang University, Key Laboratory of Kidney Disease Prevention and Control Technology, Zhejiang Province, Hangzhou, 310003, China
| | - Weiqiang Lin
- Kidney Disease Center, The First Affiliated Hospital, Zhejiang University School of Medicine, Institute of Nephrology, Zhejiang University, Key Laboratory of Kidney Disease Prevention and Control Technology, Zhejiang Province, Hangzhou, 310003, China.,Institute of Translational Medicine, Zhejiang University School of Medicine, Hangzhou, 310029, China
| |
Collapse
|
14
|
Ramalingam M, Ponnusamy VK, Sangilimuthu SN. A nanocomposite consisting of porous graphitic carbon nitride nanosheets and oxidized multiwalled carbon nanotubes for simultaneous stripping voltammetric determination of cadmium(II), mercury(II), lead(II) and zinc(II). Mikrochim Acta 2019; 186:69. [DOI: 10.1007/s00604-018-3178-7] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Accepted: 12/12/2018] [Indexed: 12/31/2022]
|