1
|
Wang X, Zhang F, Ma D, Ye X, Zheng X, Ren R, Bai S. Coordinate-based data analysis of the accuracy of five intraoral scanners for scanning completely dentate and partially edentulous mandibular arches. J Prosthet Dent 2024:S0022-3913(24)00010-6. [PMID: 38342644 DOI: 10.1016/j.prosdent.2024.01.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 01/08/2024] [Accepted: 01/10/2024] [Indexed: 02/13/2024]
Abstract
STATEMENT OF PROBLEM Current methods for assessing the accuracy of intraoral scanners (IOSs) that reduce errors and provide comprehensive data compared with previous methods are lacking. PURPOSE The purpose of this in vitro study was to present a coordinate-based data analysis method to compare the accuracy of 5 IOSs for scanning completely dentate and partially edentulous casts. MATERIAL AND METHODS Reference scans of 2 complete arch casts (completely and partially dentate) were digitized using a high-precision laboratory scanner (Ceramill Map 600). Each cast was scanned 10 times each using 5 IOSs (3Shape TRIOS 3, Planmeca Emerald, iTero Element 5D, Medit i500, and Shining Aoralscan 3). The dataset of all 10 test groups was analyzed by using a reverse engineering software program (Geomagic Wrap). Each test cast was aligned with the reference cast by 3-dimensional (3D) superimposition to determine the translation and rotation along the x-, y-, and z-axes. The dataset was analyzed using the Kruskal-Wallis and post hoc Bonferroni tests (α=.05). RESULTS Significant differences were observed in all parameters among all scanners when scanning the same cast (P<.05). Significant differences were observed in at least 1 parameter for all scanners, except Element 5D after scanning different casts using the same scanner. Deviations in the test data generally relocated toward the mesial, buccal, and apical sides, and the casts were almost always rotated clockwise around the y-axis and counterclockwise around the z-axis. For the completely dentate cast, among all IOSs, Element 5D demonstrated the highest accuracy in most of the measured parameters, specifically in the y-axis translation (0.06[0.07] mm), z-axis translation (0.08[0.05] mm), and y-axis rotation (0.21[0.16] degree) (P<.05). For the partially edentulous cast, Element 5D displayed higher accuracy in most of the measured parameters, including the x-axis translation (0.11[0.14] mm) and z-axis rotation (0.12[0.18] degree) (P<.05). Emerald also displayed higher accuracy in most of the measured parameters, including the y-axis translation (0.05[0.08] mm) and y-axis rotation (0.14[0.12] degree) (P<.05). Element 5D exhibited no difference in the scanning accuracy between the 2 types of casts (P>.05). CONCLUSIONS Element 5D offered a high level of accuracy and was an appropriate scanner for both situations. The method presented in this study provides a good assessment of accuracy deviations in complete arch scans using 3D coordinate-based data analysis.
Collapse
Affiliation(s)
- Xin Wang
- Graduated Student, State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, PR China
| | - Fang Zhang
- Dental Technologist, State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, PR China
| | - Dan Ma
- Graduated Student, State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, PR China
| | - Xiaolan Ye
- Dental Technologist, State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, PR China
| | - Xiaojuan Zheng
- Dental Nurse, State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, PR China
| | - Ruifang Ren
- Dental Technologist, State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, PR China
| | - Shizhu Bai
- Associate Professor, State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, PR China.
| |
Collapse
|
2
|
Schmidt A, Berschin C, Wöstmann B, Schlenz MA. Chairside 3-D printed impression trays: a new approach to increase the accuracy of conventional implant impression taking? An in vitro study. Int J Implant Dent 2023; 9:47. [PMID: 38052992 DOI: 10.1186/s40729-023-00516-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Accepted: 11/21/2023] [Indexed: 12/07/2023] Open
Abstract
PURPOSE A high transfer accuracy of the intraoral implant position to a model is required, to manufacture implant-supported restorations. However, clinically relevant deviations persist between the intraoral implant position and the model obtained, even for the benchmark conventional custom implant impressions with polyether. Thus, new approaches using 3-D printed impression trays may increase the transfer accuracy of implant impressions. The ability to adjust parameters such as the thickness of the layers and the influence of the openings in the impression tray could potentially affect accuracy. METHODS Four different types of impression trays (n = 10 for each group) for the conventional impression technique were investigated: conventional custom impression tray, customized foil tray, chairside 3-D printed impression tray with the SHERA system, and the Primeprint system using an implant master model with four implants in the posterior region and a reference cube. After plaster model casting, all models were measured using a coordinate measuring machine, and the deviation from the reference dataset was determined. A statistical ANOVA analysis was performed (p < 0.05). RESULTS Chairside 3-D printed impression trays showed the best results, followed by conventional custom impression trays. Implant impressions obtained using a customized foil tray exhibited the lowest accuracy. Statistically significant differences were observed between 3-D printed impression trays and conventional custom impression and customized foil trays (p < 0.05). Whereas, the implant position did not have any significant influence on accuracy (p > 0.05). CONCLUSIONS Chairside 3-D printed impression trays significantly increase the transfer accuracy for implant impression taking.
Collapse
Affiliation(s)
- Alexander Schmidt
- Department of Prosthodontics, Dental Clinic, Justus Liebig University, Schlangenzahl 14, 35392, Giessen, Germany
| | - Cara Berschin
- Department of Prosthodontics, Dental Clinic, Justus Liebig University, Schlangenzahl 14, 35392, Giessen, Germany
| | - Bernd Wöstmann
- Department of Prosthodontics, Dental Clinic, Justus Liebig University, Schlangenzahl 14, 35392, Giessen, Germany
| | - Maximiliane Amelie Schlenz
- Department of Prosthodontics, Dental Clinic, Justus Liebig University, Schlangenzahl 14, 35392, Giessen, Germany.
| |
Collapse
|
3
|
El Charkawi H, Nassar HI, Abdelaziz MS. Retrospective digital study of mandibular flexure in patients with long-span fixed restorations supported by natural teeth. BMC Res Notes 2023; 16:203. [PMID: 37697386 PMCID: PMC10494340 DOI: 10.1186/s13104-023-06486-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Accepted: 08/30/2023] [Indexed: 09/13/2023] Open
Abstract
PURPOSE This retrospective study aims to evaluate the mandibular flexure on a long-span rigid fixed prosthesis supported by natural teeth. MATERIALS AND METHODS Nine patients (five males and four females) were included in this study who had long-span rigid mandibular fixed prostheses for long-term (10-15 years) that have led to radiographic changes around the supporting teeth. The mandibular flexure was measured digitally after adhering reference markers to the prostheses. Intraoral scans were obtained at the minimum and maximum mouth openings before and after splitting the preexisting prostheses. The distances between the markers were measured, and mandibular flexure was calculated. RESULTS This study showed a significant deviation (narrowing) of the mandible before and after splitting the rigid fixed prostheses (P value < 0.05). CONCLUSION Digital analysis of the data collected from the patients in this retrospective study indicated that deviations occur during mandibular flexure. CLINICAL RELEVANCE Splitting the full arch prosthesis could prevent the negative consequences of mandibular flexure on restorations. Trial registration The study was registered on clinicaltrials.gov with registration number NCT05617274 (15/11/2022).
Collapse
Affiliation(s)
- Hussein El Charkawi
- Department of Prosthodontics, Faculty of Oral and Dental Medicine, Future University in Egypt, Fifth Settlement, End of 90 Street, New Cairo, Egypt
| | - Hossam I Nassar
- Department of Prosthodontics, Faculty of Oral and Dental Medicine, Future University in Egypt, Fifth Settlement, End of 90 Street, New Cairo, Egypt
| | - Medhat Sameh Abdelaziz
- Department of Prosthodontics, Faculty of Oral and Dental Medicine, Future University in Egypt, Fifth Settlement, End of 90 Street, New Cairo, Egypt.
| |
Collapse
|
4
|
Caggiano M, D’Ambrosio F, Acerra A, Giudice D, Giordano F. Biomechanical Implications of Mandibular Flexion on Implant-Supported Full-Arch Rehabilitations: A Systematic Literature Review. J Clin Med 2023; 12:5302. [PMID: 37629344 PMCID: PMC10455661 DOI: 10.3390/jcm12165302] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 08/03/2023] [Accepted: 08/09/2023] [Indexed: 08/27/2023] Open
Abstract
BACKGROUND Mandibular flexion (MF) is a complex biomechanical phenomenon, which involves a deformation of the mandible, due mainly to the contraction of the masticatory muscles, and it can have numerous clinical effects. The deformation of the lower jaw caused by mandibular flexion is generally very small, and it is often overlooked and considered irrelevant from a clinical point of view by many authors; however, it should be important to remember that median mandibular flexure (MMF) has a multifactorial aetiology. The main aim of the current systematic review is to highlight the different factors that can increase MF in order to help clinicians identify patients to whom they should pay more attention. As a secondary outcome, we wanted to analyse the preventive measures and suitable techniques to be adopted to minimise the negative effects of this phenomenon on oral fixed rehabilitations. METHODS The review, which was carried out in accordance with the "Preferred Reporting Items for Systematic reviews and Meta-Analyses" (PRISMA) flowchart, was recorded in the "International Prospective Register of Systematic Reviews" (PROSPERO). As research questions, "Patient/Population, Intervention, Comparison and Outcomes" (PICO) questions were employed. Using the ROBINS-I technique, the risk of bias in non-randomised clinical studies was evaluated. RESULTS The initial electronic search identified over 1300 potential articles, of which 54 studies were included in this systematic review. Information regarding the relationship between MF and individual factors, mandibular movements, impression taking, and fixed rehabilitations were obtained. CONCLUSIONS The studies included in this systematic review showed that MF is greater during protrusive movements, in the posterior areas of the lower jaw, and in patients with brachial facial type, greater jaw length; small gonial angle; and less density, length, and bone surface of the symphysis. The biomechanical effects of mandibular flexion on fixed restorations are debated. Prospective clinical and radiological observational studies should be conducted to evaluate the potential short-, medium-, and long-term consequences of MF.
Collapse
Affiliation(s)
- Mario Caggiano
- Department of Medicine, Surgery and Dentistry, University of Salerno, Via Allende, Baronissi, 84081 Salerno, Italy; (F.D.); (D.G.); (F.G.)
| | | | - Alfonso Acerra
- Department of Medicine, Surgery and Dentistry, University of Salerno, Via Allende, Baronissi, 84081 Salerno, Italy; (F.D.); (D.G.); (F.G.)
| | | | | |
Collapse
|
5
|
Londono J, Schoenbaum TR, Varilla Ortiz AV, Franco-Romero G, Villalobos V, Carosi P, Mijiritsky E, Pozzi A. Mandibular Flexure and Its Significance: An In Vivo Cone Beam-Computed Tomography Proof-of-Concept Study. J Clin Med 2023; 12:4149. [PMID: 37373841 PMCID: PMC10299314 DOI: 10.3390/jcm12124149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 06/11/2023] [Accepted: 06/16/2023] [Indexed: 06/29/2023] Open
Abstract
The aim of this study was to assess intra-arch mandibular dimensional changes that may occur during mouth opening using cone beam-computed tomography (CBCT). Fifteen patients in need of any type of treatment whose execution considered a pre- and post-CBCT assessment consented and were enrolled. CBCTs were taken with the following settings: 90 kV, 8 mA, field of view (FOV) 140 by 100 mm (height and diameter), Voxel size 0.25 mm (high resolution). The pre-CBCT was executed in the maximum mandibular opening (MO), while the post-CBCT was in the maximum intercuspation (MI). A thermoplastic stent with radiopaque fiducial markers (steel ball bearings) was fabricated for each patient. Measurements were made using radiographic markers between contralateral canines and contralateral first molars and between ipsilateral canines and first molars on both sides. Paired t-tests were performed to evaluate the difference between open and closed positions on these four measurements. In the MO position were registered a significative tightening of the mandible at the canine (-0.49 mm, SD 0.54 mm; p < 0.001) and molar points (-0.81 mm, SD 0.63 mm; p < 0.001) and a significative shortening of the mandible on the right (-0.84 mm, SD 0.80 mm; p < 0.001) and left sides (-0.87 mm, SD 0.49 mm; p < 0.001). Within the study limitations, mandibular flexure determined a significant shortening and tightening between maximum intercuspation to maximum opening positions. Mandibular dimensional changes should be considered in light of other patient factors in the treatment planning of implant positioning and long-span complete arch implant-supported fixed prostheses in order to avoid technical complications.
Collapse
Affiliation(s)
- Jimmy Londono
- Ronald Goldstein Center for Esthetic and Implant Dentistry, Department of Restorative Sciences, Dental College of Georgia, Augusta, GA 30912, USA;
| | - Todd R. Schoenbaum
- Department of Restorative Sciences, Dental College of Georgia, Augusta, GA 30912, USA; (T.R.S.); (V.V.)
| | | | - Guillermo Franco-Romero
- Stomatology and Oral Rehabilitation Residency Program, Benemerita Universidad Autonoma de Puebla, Puebla 72000, Mexico;
| | - Vanessa Villalobos
- Department of Restorative Sciences, Dental College of Georgia, Augusta, GA 30912, USA; (T.R.S.); (V.V.)
| | - Paolo Carosi
- Department of Clinical Sciences and Translational Medicine, School of Dentistry, University of Tor Vergata, 00133 Rome, Italy;
| | - Eitan Mijiritsky
- The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv 6997801, Israel;
- Head and Neck Maxillofacial Surgery, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6139001, Israel
| | - Alessandro Pozzi
- Ronald Goldstein Center for Esthetic and Implant Dentistry, Department of Restorative Sciences, Dental College of Georgia, Augusta, GA 30912, USA;
- Department of Clinical Sciences and Translational Medicine, School of Dentistry, University of Tor Vergata, 00133 Rome, Italy;
| |
Collapse
|
6
|
Bock NC, Klaus K, Liebel MM, Ruf S, Wöstmann B, Schlenz MA. What to Prefer in Patients with Multibracket Appliances? Digital vs. Conventional Full-Arch Impressions-A Reference Aid-Based In Vivo Study. J Clin Med 2023; 12:jcm12093071. [PMID: 37176511 PMCID: PMC10179177 DOI: 10.3390/jcm12093071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 04/17/2023] [Accepted: 04/20/2023] [Indexed: 05/15/2023] Open
Abstract
This study aimed to investigate the transfer accuracy and required time for digital full-arch impressions obtained from intraoral scanners (IOSs) versus conventional alginate impressions (CAIs) in patients with multibracket appliances (MBA). Thirty patients with buccal MBAs (metal brackets, archwire removed) were examined using an established reference aid method. Impression-taking using four IOSs (Primescan, Trios 4, Medit i700, Emerald S) and one CAI with subsequent plaster casting were conducted. One-hundred-twenty (n = 30 × 4) scans were analyzed with 3D software (GOM Inspect) and 30 (n = 30 × 1) casts were assessed using a coordinate measurement machine. Six distances and six angles were measured and compared to the reference aid values (ANOVA; p < 0.05). Except for the intermolar distance, transfer accuracy was significantly higher with IOSs than with CAIs (p < 0.05). No such difference was found regarding the six angles. In patients with MBAs, digital impression-taking using IOSs can be recommended. For all measured variables except one, the transfer accuracy of IOSs was better than or at least equivalent to the data from CAIs. In addition, significantly (p < 0.001) less time was necessary for all IOSs in comparison to CAIs plus plaster casting.
Collapse
Affiliation(s)
- Niko Christian Bock
- Department of Orthodontics, Dental Clinic, Justus Liebig University, Schlangenzahl 14, 35392 Giessen, Germany
| | - Katharina Klaus
- Department of Orthodontics, Dental Clinic, Justus Liebig University, Schlangenzahl 14, 35392 Giessen, Germany
| | - Moritz Maximilian Liebel
- Department of Orthodontics, Dental Clinic, Justus Liebig University, Schlangenzahl 14, 35392 Giessen, Germany
| | - Sabine Ruf
- Department of Orthodontics, Dental Clinic, Justus Liebig University, Schlangenzahl 14, 35392 Giessen, Germany
| | - Bernd Wöstmann
- Department of Prosthodontics, Dental Clinic, Justus Liebig University, Schlangenzahl 14, 35392 Giessen, Germany
| | - Maximiliane Amelie Schlenz
- Department of Prosthodontics, Dental Clinic, Justus Liebig University, Schlangenzahl 14, 35392 Giessen, Germany
| |
Collapse
|
7
|
Schlenz MA, Klaus K, Schmidt A, Wöstmann B, Mersmann M, Ruf S, Bock NC. The transfer accuracy of digital and conventional full-arch impressions influenced by fixed orthodontic appliances: a reference aid-based in vitro study. Clin Oral Investig 2023; 27:273-283. [PMID: 36109373 PMCID: PMC9876864 DOI: 10.1007/s00784-022-04721-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Accepted: 09/06/2022] [Indexed: 01/29/2023]
Abstract
OBJECTIVES The aim of this in vitro study was to investigate the influence of fixed orthodontic appliances (FOAs) on the transfer accuracy of full-arch impressions by five intraoral scanners (IOSs): CS3600, Primescan, Trios 4, Medit i500, Emerald S, and one conventional alginate impression (CAI). MATERIALS AND METHODS To compare the data with the actual model situation, an established reference aid-based method was applied. A test model with human teeth was used and modified for each testing group, resulting in five different settings: natural teeth (group A), metal brackets without/with wire (groups B/C), ceramic brackets without/with wire (groups D/E). A total of 300 (n = 12 × 5 × 5) scan datasets of IOSs were analyzed using a 3D software (GOM Inspect) and 60 (n = 12 × 5) plaster casts of CAI were measured with a coordinate measurement machine. The deviations between the reference aid and the impressions were determined. RESULTS For all groups with brackets (B to E), IOSs showed a higher transfer accuracy compared to CAI, even for long-span distances. However, some significant differences between the IOSs were observed (p < 0.05). CONCLUSIONS Within the limitations of this in vitro study, IOSs can be recommended for impressions with and without FOAs, even if CAI showed the smallest average deviations in settings without FOAs. CLINICAL RELEVANCE IOSs are widely used in orthodontics and the current study demonstrated that their use enables fast impression taking even in settings with fixed orthodontic appliances. In addition, for these settings, the transfer accuracy is higher than with conventional alginate impressions. Nevertheless, a re-investigation in a clinical setting should be performed to verify the current in vitro findings.
Collapse
Affiliation(s)
- Maximiliane Amelie Schlenz
- Department of Prosthodontics, Dental Clinic of the Justus Liebig University Giessen, Schlangenzahl 14, 35392 Giessen, Germany
| | - Katharina Klaus
- Department of Orthodontics, Dental Clinic of the Justus Liebig University Giessen, Schlangenzahl 14, 35392 Giessen, Germany
| | - Alexander Schmidt
- Department of Prosthodontics, Dental Clinic of the Justus Liebig University Giessen, Schlangenzahl 14, 35392 Giessen, Germany
| | - Bernd Wöstmann
- Department of Prosthodontics, Dental Clinic of the Justus Liebig University Giessen, Schlangenzahl 14, 35392 Giessen, Germany
| | - Marco Mersmann
- Department of Orthodontics, Dental Clinic of the Justus Liebig University Giessen, Schlangenzahl 14, 35392 Giessen, Germany
| | - Sabine Ruf
- Department of Orthodontics, Dental Clinic of the Justus Liebig University Giessen, Schlangenzahl 14, 35392 Giessen, Germany
| | - Niko Christian Bock
- Department of Orthodontics, Dental Clinic of the Justus Liebig University Giessen, Schlangenzahl 14, 35392 Giessen, Germany
| |
Collapse
|
8
|
Mijiritsky E, Shacham M, Meilik Y, Dekel-Steinkeller M. Clinical Influence of Mandibular Flexure on Oral Rehabilitation: Narrative Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:16748. [PMID: 36554629 PMCID: PMC9778818 DOI: 10.3390/ijerph192416748] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 12/11/2022] [Accepted: 12/12/2022] [Indexed: 06/17/2023]
Abstract
AIM The current paper aims to review mandibular flexure and its clinical implications in the field of oral rehabilitation. Mandibular flexure is a deformity of the mandible, which occurs during jaw movements. METHODS AND MATERIALS An electronic database search was conducted using the PRISM model, with a total of 49 articles included. RESULTS Mandibular flexure affects various stages of oral rehabilitation treatments. Effects of mandibular flexure are more significant in periodontal patients, and in implant-supported restorations, compared to natural teeth, due to differences in the force absorption by the periodontal ligament. Various adjustments must be made to the prosthodontic framework to enable long-term survival of the restorative treatments. CONCLUSIONS Dental practitioners should pay attention to the following: (1) digital impressions are preferred over conventional; (2) mouth opening should be kept to a minimum (as possible, up to 10-20 mm) while also avoiding any anterior movements of the mandible (protrusion); (3) the number of abutment teeth should be kept to a minimum; (4) structures in the lower jaw should be splitted; (5) non-rigid connectors should be used to reduce the effort exerted; (6) in periodontal patients, the preference is for short-span restorations and non-rigid connectors; (7) in implant-supported restorations, it is preferable to divide the framework into two or three segments, utilizing rigid materials with a low elastic modulus. There is no agreement in the literature about the preferred location of the implants in the jaw.
Collapse
Affiliation(s)
- Eitan Mijiritsky
- The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
- Department of Otolaryngology, Head and Neck and Maxillofacial Surgery, Tel-Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv 6139001, Israel
| | - Maayan Shacham
- School of Social Work, Ariel University, Ariel 40700, Israel
| | - Yuval Meilik
- The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Michal Dekel-Steinkeller
- The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| |
Collapse
|
9
|
Update on the Accuracy of Conventional and Digital Full-Arch Impressions of Partially Edentulous and Fully Dentate Jaws in Young and Elderly Subjects: A Clinical Trial. J Clin Med 2022; 11:jcm11133723. [PMID: 35807008 PMCID: PMC9267135 DOI: 10.3390/jcm11133723] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 06/21/2022] [Accepted: 06/25/2022] [Indexed: 02/06/2023] Open
Abstract
To update the available literature on the accuracy of conventional and digital full-arch impressions using the latest hardware and software, participants of different age groups and dental status were investigated. An established reference aid-based method was applied to analyze five intraoral scanners (IOS) CS 3800 (CS), iTero Element 5D (IT), Medit i700 (ME), Primescan (PS), and Trios 4 (TR), and one conventional polyether impression (CVI). Forty-five participants were classified into three groups: Age 27.3 ± 2.7 years fully dentate, 60.6 ± 8.1 years fully dentate, and 65.7 ± 6.2 years partially edentulous. The IOS datasets were investigated using three-dimensional software (GOM Inspect), and plaster casts of CVI were analyzed using a co-ordinate measurement machine. The deviations of the reference aid to impressions were determined. No significant differences in age between the three groups were observed by the IOS in terms of trueness (p < 0.05). These findings were confirmed for precision, except for TR. In contrast to CS (mean ± standard deviation 98.9 ± 62.1 µm) and IT (89.0 ± 91.0 µm), TR (58.3 ± 66.8 µm), ME (57.9 ± 66.7 µm), and PS (55.5 ± 48.7 µm) did not show significant differences than those of CVI (34.8 ± 29.6 µm) in overall view. Within the study, the latest IOSs still showed limitations in the accuracy of full-arch impressions. However, they seemed to be unaffected by age and fully dentate or partially edentulous dentitions with small gaps.
Collapse
|
10
|
Gülsoy M, Tuna SH, Pekkan G. Evaluation of median mandibular flexure values in dentulous and edentulous subjects by using an intraoral digital scanner. J Adv Prosthodont 2022; 14:32-44. [PMID: 35284055 PMCID: PMC8891685 DOI: 10.4047/jap.2022.14.1.32] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 12/23/2021] [Accepted: 01/25/2022] [Indexed: 11/16/2022] Open
Abstract
PURPOSE Mandibular flexure is a crucial phenomenon that may affect the success of rigid bilateral mandibular prosthetic treatment. The aim of this study was to determine the amount of median mandibular flexure (MMF) that occurs during mouth opening from anterior to posterior mandible in seven different regions, in different age and gender groups of both dentulous and edentulous subjects, using an intraoral digital scanner. MATERIALS AND METHODS In this study, the mandibular arch of 56 dentulous and 35 edentulous individuals were scanned with an intraoral scanner at both the minimum mouth opening (MnMO) and the maximum mouth opening (MxMO). MMF values were calculated by subtracting the distance value at the MxMO from the distance between the reference points at the MnMO at seven different mandibular regions of dentulous and edentulous subjects. In addition, the left and right side MMF values were measured. All data were analyzed statistically (α = .05). RESULTS MMF value increased linearly from anterior to posterior mandible in both dentulous and edentulous individuals. The differences in MMF values were not statistically significant according to side (left/right), age, or gender (P > .05). No significant differences were found between the mean MMF values of the same region in both dentulous and edentulous individuals (P > .05). CONCLUSION MMF was seen in different regions of the mandibles of both edentulous and dentulous individuals measured at the MxMO. Mandibular flexure should be considered for the success and prognosis of the long-span and rigid prostheses.
Collapse
Affiliation(s)
- Merve Gülsoy
- Department of Prosthodontics, Faculty of Dentistry, Süleyman Demirel University, Isparta, Turkey
| | - Süleyman Hakan Tuna
- Department of Prosthodontics, Faculty of Dentistry, Süleyman Demirel University, Isparta, Turkey
| | - Gürel Pekkan
- Department of Prosthodontics, Faculty of Dentistry, Tekirdag Namik Kemal University, Tekirdag, Turkey
| |
Collapse
|