1
|
Zhao X, Zhang L, Chu Z, Wang Q, Cao Y, Cao J, Li J, Lei W, Zhang B, Si W. Fe–Decorated Nitrogen–Doped Carbon Nanospheres as an Electrochemical Sensing Platform for the Detection of Acetaminophen. Molecules 2023; 28:molecules28073006. [PMID: 37049770 PMCID: PMC10095704 DOI: 10.3390/molecules28073006] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 03/17/2023] [Accepted: 03/18/2023] [Indexed: 03/30/2023] Open
Abstract
In this work, Fe–decorated nitrogen–doped carbon nanospheres are prepared for electrochemical monitoring of acetaminophen. Via a direct pyrolysis of the melamine–formaldehyde resin spheres, the well–distributed Fe–NC spheres were obtained. The as–prepared Fe–NC possesses enhanced catalysis towards the redox of acetaminophen for abundant active sites and high–speed charge transfer. The effect of loading Fe species on the electrochemical sensing of acetaminophen is investigated in detail. The synergistic effect of nitrogen doping along with the above–mentioned properties is taken advantage of in the fabrication of electrochemical sensors for the acetaminophen determination. Based on the calibration plot, the limits of detection (LOD) were calculated to be 0.026 μM with a linear range from 0–100 μM. Additionally satisfactory repeatability, stability, and selectivity are obtained.
Collapse
Affiliation(s)
- Xiangchuan Zhao
- School of Materials Science and Engineering, Shandong University of Technology, Xincunxi Road 266th, Zibo 255000, China
- Institute of Advanced Materials, Shandong Institutes of Industrial Technology, Jinan 250000, China
| | - Liping Zhang
- School of Materials Science and Engineering, Shandong University of Technology, Xincunxi Road 266th, Zibo 255000, China
| | - Zhaoyun Chu
- School of Materials Science and Engineering, Shandong University of Technology, Xincunxi Road 266th, Zibo 255000, China
| | - Qing Wang
- School of Materials Science and Engineering, Shandong University of Technology, Xincunxi Road 266th, Zibo 255000, China
| | - Yue Cao
- School of Materials Science and Engineering, Shandong University of Technology, Xincunxi Road 266th, Zibo 255000, China
| | - Jun Cao
- School of Materials Science and Engineering, Shandong University of Technology, Xincunxi Road 266th, Zibo 255000, China
| | - Jiao Li
- School of Materials Science and Engineering, Shandong University of Technology, Xincunxi Road 266th, Zibo 255000, China
| | - Wu Lei
- School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Xiaolingwei 200th, Nanjing 210094, China
| | - Boming Zhang
- Institute of Advanced Materials, Shandong Institutes of Industrial Technology, Jinan 250000, China
| | - Weimeng Si
- School of Materials Science and Engineering, Shandong University of Technology, Xincunxi Road 266th, Zibo 255000, China
- Correspondence:
| |
Collapse
|
2
|
Electrochemical sensor based on epoxy-functionalized BEA nanozeolite and graphene oxide modified glassy carbon electrode for bisphenol E determination. J APPL ELECTROCHEM 2023. [DOI: 10.1007/s10800-023-01875-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/19/2023]
Abstract
AbstractAn epoxy-functionalized beta type nanozeolite (BEA)/graphene oxide nanocomposite modified glassy carbon electrode (GCE/BEA/APTMS/GA/GO/NF) has been created for the differential pulse voltammetric determination of bisphenol E (BPE). The modified electrode presented an enhanced current response in comparison with bare GCE. A linear dependence of anodic peak current (Ip) and scan rate (ν) was observed, which showed that the electrochemical process was adsorption-controlled. Differential pulse voltammetry (DPV) was employed and optimized for the sensitive determination of BPE. Under the optimized conditions, the anodic peak current was linearly proportional to BPE concentration in the range between 0.07 and 4.81 µM, with a correlation coefficient of 0.995 and limit of detection 0.056 μM (S/N = 3). The electrode showed good repeatability and storage stability, and a low response to interfering compounds. Comparison was made to the determination of bisphenol A. To confirm the electrode analytical performance, recovery tests were performed, and deviations lower than 10% were found. The BEA zeolite-GO nanocomposite proved to be a promising sensing platform for bisphenol determination.
Graphical abstract
Collapse
|
3
|
Individual and Simultaneous Electrochemical Detection of Bisphenol A and Bisphenol S in Food Samples Using Triethylenetetramine Functionalized Multi-Walled Carbon Nanotubes. FOOD ANAL METHOD 2022. [DOI: 10.1007/s12161-022-02409-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
4
|
CERYAN A, ELTUĞRAL N. Isotherm and thermodynamic studies on the removal of gelatin-stabilized silver nanoparticles from water by activated carbon. JOURNAL OF THE TURKISH CHEMICAL SOCIETY, SECTION A: CHEMISTRY 2022. [DOI: 10.18596/jotcsa.1098891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Gelatin-stabilized silver nanoparticles (AgNPs) with a particle size of 6.9 (±3.2) nm were synthesized and employed in nanoparticle adsorption onto activated carbon (AC). Subsequently, the synthesized AgNPs and the adsorbed nanoparticles onto the AC (AgNP@AC) were characterized by various techniques including UV–Vis spectrophotometry, transmission electron microscopy (TEM), scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT–IR) and X–ray diffraction (XRD). AgNPs possessed colloidal stability at a wide pH interval ranging between 4 and 13. Adsorption was studied batch-wise as a function of initial nanoparticle concentration (4–14 mg L-1), temperature (298–323 K), pH (4–13) and adsorbent dosage (0.01–0.05 g). Adsorption isotherms were investigated by fitting the data to different isotherm models including Langmuir, Freundlich, Temkin, and Dubinin–Radushkevich (D–R). Error analysis indicated that the adsorption is well described by the Langmuir model with a monolayer adsorption capacity of 10.36 mg g-1 for 0.05 g AC at pH 7 and 323 K. Thermodynamic parameters such as enthalpy (66.77 kJ mol-1), entropy (232.92 J mol-1 K-1), and Gibbs free energy (–8.31 kJ mol-1) indicated that the process is endothermic, favorable and spontaneous through physical interactions.
Collapse
|
5
|
Acharya PB, George A, Shrivastav PS. A Status Update on the Development of Polymer and Metal-Based Graphene Electrochemical Sensors for Detection and Quantitation of Bisphenol A. Crit Rev Anal Chem 2022; 54:669-690. [PMID: 35776701 DOI: 10.1080/10408347.2022.2094197] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
The detection and quantitation of bisphenol A (BPA) in the environment and food products has been a subject of considerable interest. BPA, a diphenylmethane derivative is a well-known industrial raw material with wide range of applications. It is a well-known endocrine disruptor and acts as an estrogen mimic. BPA is an environmental health concern and its accumulation in hydro-geological cycles is a matter of serious ecological peril. This review basically assesses various chemically modified electrodes composed of diverse components that have been employed to recognize BPA in different matrices. Electrochemical sensors prepared using graphene materials in combination with metals and polymers for selective detection of BPA have been discussed extensively. The emphasis is on detection of BPA in various samples encountered in routine use such as plastic bottles, receipts, baby feed bottles, milk samples, mineralized water, tissue paper, DVDs, and others. Although research in this field is in the exploratory stage, deeper insights into fundamental studies of sensing systems, fast analysis of real samples and validation of sensors are some of the factors that need major impetus. It is expected that chemically modified electrode-based sensing systems will soon take over as a viable option for monitoring diverse pollutants.
Collapse
Affiliation(s)
- Prachi B Acharya
- Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad, Gujarat, India
| | - Archana George
- Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad, Gujarat, India
| | - Pranav S Shrivastav
- Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad, Gujarat, India
| |
Collapse
|
6
|
Zine A, Ferkhi M, Khaled A, Kuyumcu Savan E. A2BO4±δ as New Materials for Electrocatalytic Detection of Paracetamol and Diclofenac Drugs. Electrocatalysis (N Y) 2022. [DOI: 10.1007/s12678-022-00745-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
7
|
Green Synthesis of ZnO/BC Nanohybrid for Fast and Sensitive Detection of Bisphenol A in Water. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10050163] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
A nanohybrid of zinc oxide and biochar (ZnO/BC) with high conductivity was green synthesized using a simple hydrothermal method, and utilized for the sensitive detection of bisphenol A (BPA) by coating the nanohybrid film on an electrode of glassy carbon. The ZnO/BC presented greatly improved electrocatalytic performance and electron transfer ability compared to the zinc oxide and biochar. The ZnO/BC film-coated electrode could detect the BPA in aqueous solution within 3 min while neglected interference from higher concentrations of regularly existing ions and similar concentrations of estradiol (E2), phenol, dichlorophenol (DCP), and ethinylestradiol (EE2). Under optimal conditions, the linear range of BPA detection was 5 × 10−7~1 × 10−4 mol/L, with a detection limit of 1 × 10−7 mol/L, and the detection sensitivity was 92 mA/M. In addition, the ZnO/BC electrode could detect BPA in a real water sample with good signal recovery. This electrode, with the advantages of an easy preparation, low cost, and fast response time, could be potentially applicable for environmental monitoring.
Collapse
|
8
|
Santos Fernandes J, Fernandes JO, Bernardino CAR, Mahler CF, Braz BF, Santelli RE, Cincotto FH. A New Electrochemical Sensor Based on Carbon Black Modified With Palladium Nanoparticles for Direct Determination of 17α‐ethinylestradiol in Real Samples. ELECTROANAL 2022. [DOI: 10.1002/elan.202100474] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Juliana Santos Fernandes
- Department of Analytical Chemistry Institute of Chemistry Universidade Federal do Rio de Janeiro Rio de Janeiro Brazil
| | - Julia Oliveira Fernandes
- Department of Analytical Chemistry Institute of Chemistry Universidade Federal do Rio de Janeiro Rio de Janeiro Brazil
| | | | - Claudio Fernando Mahler
- Department of Civil Engineering COPPE Universidade Federal do Rio de Janeiro Rio de Janeiro Brazil
| | - Bernardo Ferreira Braz
- Department of Analytical Chemistry Institute of Chemistry Universidade Federal do Rio de Janeiro Rio de Janeiro Brazil
| | - Ricardo Erthal Santelli
- Department of Analytical Chemistry Institute of Chemistry Universidade Federal do Rio de Janeiro Rio de Janeiro Brazil
- National Institute of Science & Technology of Bioanalytics (INCTBio) Brazil
| | - Fernando Henrique Cincotto
- Department of Analytical Chemistry Institute of Chemistry Universidade Federal do Rio de Janeiro Rio de Janeiro Brazil
- National Institute of Science & Technology of Bioanalytics (INCTBio) Brazil
| |
Collapse
|
9
|
Zhang L, Tao H, Ji C, Wu Q, Wang X, Wu Y. Sensitive and direct electrochemical detection of bisphenol S based on 1T&2H-MoS 2/CNTs-NH 2 nanocomposites. NEW J CHEM 2022. [DOI: 10.1039/d2nj00866a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A voltammetric sensor was constructed for ultra-trace BPS detection based on the signal amplification effect of 1T&2H-MoS2 and CNTs-NH2 composites.
Collapse
Affiliation(s)
- Lingli Zhang
- School of Liquor and Food Engineering, Guizhou University, Guiyang 550025, China
- Key Laboratory of Fermentation Engineering and Biopharmacy of Guizhou Province, Guizhou University, Guiyang 550025, China
| | - Han Tao
- School of Liquor and Food Engineering, Guizhou University, Guiyang 550025, China
- Key Laboratory of Fermentation Engineering and Biopharmacy of Guizhou Province, Guizhou University, Guiyang 550025, China
| | - Chun Ji
- School of Pharmaceutical Sciences, Guizhou University, Guiyang 550025, China
| | - Qiaoling Wu
- School of Liquor and Food Engineering, Guizhou University, Guiyang 550025, China
- Key Laboratory of Fermentation Engineering and Biopharmacy of Guizhou Province, Guizhou University, Guiyang 550025, China
| | - Xiao Wang
- School of Liquor and Food Engineering, Guizhou University, Guiyang 550025, China
- Key Laboratory of Fermentation Engineering and Biopharmacy of Guizhou Province, Guizhou University, Guiyang 550025, China
| | - Yuangeng Wu
- School of Liquor and Food Engineering, Guizhou University, Guiyang 550025, China
- Key Laboratory of Fermentation Engineering and Biopharmacy of Guizhou Province, Guizhou University, Guiyang 550025, China
| |
Collapse
|
10
|
Li H, Zhu F, Xiang J, Wang F, Liu Q, Chen X. In situ growth of ZIF-8 on gold nanoparticles/magnetic carbon nanotubes for the electrochemical detection of bisphenol A. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:2338-2344. [PMID: 33970976 DOI: 10.1039/d1ay00324k] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
We herein report a facile and scalable strategy for the fabrication of a metal-organic framework (MOF) based composite by in situ growing ZIF-8 on gold nanoparticle (AuNP) loaded magnetic carbon nanotubes (mCNTs). AuNPs were firstly loaded on PEI (polyethylenimine) modified mCNTs by electrostatic forces, and then AuNPs/mCNTs were encapsulated into the ZIF-8 frame through in situ self-assembling of zinc ions and 2-methylimidazole. The morphology, spectroscopy and structural properties of the AuNP/mCNT@ZIF-8 nanocomposites were systematically characterized. The conductivity-strain tests revealed that the in situ insertion of AuNPs/mCNTs in ZIF-8 could not only shorten the electron transfer distance between active sites and mCNTs, but also increase the dispersion of mCNTs, which would benefit the electron and mass transfer. Besides, by adopting the AuNP/mCNT@ZIF-8 nanocomposite-modified glassy carbon electrode (GCE) as the working electrode, a novel electrochemical sensor was successfully developed for the detection of bisphenol A (BPA). A linear range of BPA detection from 1 μM to 100 μM with a limit of detection of 690 nM was favorably obtained. Moreover, the developed sensor exhibited satisfactory reproducibility and superior stability with excellent anti-interference ability, and was successfully applied in the detection of BPA in real samples.
Collapse
Affiliation(s)
- Hexiang Li
- College of Chemistry and Chemical Engineering, Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Central South University, Changsha 410083, China.
| | - Fawei Zhu
- College of Chemistry and Chemical Engineering, Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Central South University, Changsha 410083, China.
| | - Jun Xiang
- Hunan Institute of Food Quality Supervision Inspection and Research, The Hunan Provincial Key Laboratory of Food Safety Monitoring and Early Warning, Changsha 410111, Hunan, China
| | - Fangbin Wang
- Hunan Institute of Food Quality Supervision Inspection and Research, The Hunan Provincial Key Laboratory of Food Safety Monitoring and Early Warning, Changsha 410111, Hunan, China
| | - Qi Liu
- College of Chemistry and Chemical Engineering, Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Central South University, Changsha 410083, China. and Hunan Institute of Food Quality Supervision Inspection and Research, The Hunan Provincial Key Laboratory of Food Safety Monitoring and Early Warning, Changsha 410111, Hunan, China
| | - Xiaoqing Chen
- College of Chemistry and Chemical Engineering, Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Central South University, Changsha 410083, China.
| |
Collapse
|
11
|
Tsekeli T, Sebokolodi TI, Karimi-Maleh H, Arotiba OA. A Silver-Loaded Exfoliated Graphite Nanocomposite Anti-Fouling Electrochemical Sensor for Bisphenol A in Thermal Paper Samples. ACS OMEGA 2021; 6:9401-9409. [PMID: 33869920 PMCID: PMC8047760 DOI: 10.1021/acsomega.0c05836] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Accepted: 02/22/2021] [Indexed: 05/24/2023]
Abstract
Silver nanoparticles (AgNPs) were synthesized separately and loaded onto the expanded layers of exfoliated graphite (EG) to form a silver nanoparticle-exfoliated graphite nanocomposite (AgNPs-EG). The AgNPs-EG was compressed into a pellet (0.6 cm in diameter) and used to prepare an electrochemical sensor for bisphenol A (BPA) in standard samples and in thermal paper. The synthesized materials were characterized by ultraviolet-visible spectrophotometry, X-ray diffraction spectroscopy, scanning electron microscopy, and energy-dispersive X-ray. The electrochemical behavior of BPA on the AgNPs-EG sensor was investigated by cyclic voltammetry and square wave voltammetry. Under optimized experimental conditions, the oxidation peak current was linearly proportional to bisphenol A concentrations in the range from 5.0 to100 μM, with a coefficient of determination (R2 ) of 0.9981. The obtained limit of detection of the method was 0.23 μM. The fabricated sensor was able to overcome electrode fouling with good reproducibility (RSD = 2.62%, n = 5) by mechanical polishing of the electrode on emery paper. The proposed method was successfully applied to determine bisphenol A in thermal paper samples and demonstrated good accuracy of 93.1 to 113% recovery.
Collapse
Affiliation(s)
- Tebogo
R. Tsekeli
- Department
of Chemical Sciences, University of Johannesburg, Doornfontein, Johannesburg 2028, South Africa
| | - Tsholofelo I. Sebokolodi
- Department
of Chemical Sciences, University of Johannesburg, Doornfontein, Johannesburg 2028, South Africa
| | - Hassan Karimi-Maleh
- Department
of Chemical Sciences, University of Johannesburg, Doornfontein, Johannesburg 2028, South Africa
- University
of Electronic Science and Technology of China, Chengdu 611731, China
| | - Omotayo A. Arotiba
- Department
of Chemical Sciences, University of Johannesburg, Doornfontein, Johannesburg 2028, South Africa
- Centre
for Nanomaterials Science Research, University
of Johannesburg, Johannesburg 2028, South Africa
| |
Collapse
|
12
|
Santos AM, Wong A, Prado TM, Fava EL, Fatibello-Filho O, Sotomayor MDPT, Moraes FC. Voltammetric determination of ethinylestradiol using screen-printed electrode modified with functionalized graphene, graphene quantum dots and magnetic nanoparticles coated with molecularly imprinted polymers. Talanta 2020; 224:121804. [PMID: 33379030 DOI: 10.1016/j.talanta.2020.121804] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Revised: 10/20/2020] [Accepted: 10/21/2020] [Indexed: 01/23/2023]
Abstract
The present work reports the development of a sensitive and selective method for ethinylestradiol detection using screen-printed electrode (SPE) modified with functionalized graphene (FG), graphene quantum dots (GQDs) and magnetic nanoparticles coated with molecularly imprinted polymers (mag@MIP). The performance of the mag@MIP sensor was compared with that of a non-molecularly imprinted sensor (mag@NIP). Chemical and physical characterizations of the mag@NIP and mag@MIP sensors were performed using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and Brunauer-Emmett-Teller (BET) techniques. The electrochemical behavior of the electrodes investigated, which included (mag@MIP)-GQDs-FG-NF/SPE, (mag@NIP)-GQDs-FG-NF/SPE, GQDs-FG-NF/SPE and FG-NF/SPE, was evaluated by cyclic voltammetry. The results obtained show a significant increase in peak current magnitude for (mag@MIP)-GQDs-FG-NF/SPE. Using square wave voltammetry experiments, the efficiency of the (mag@MIP)-GQDs-FG-NF/SPE sensor was also tested under optimized conditions. The linear response range obtained for ethinylestradiol concentration was 10 nmol L-1 to 2.5 μmol L-1, with limit of detection of 2.6 nmol L-1. The analytical signal of the (mag@MIP)-GQDs-FG-NF/SPE sensor suffered no interference from different compounds and the sensor exhibited good repeatability. The proposed sensor was successfully applied for ethynilestradiol detection in river water, serum and urine samples, where recovery rates between 96 to 105% and 97-104% were obtained for environmental and biological samples, respectively.
Collapse
Affiliation(s)
- Anderson M Santos
- Department of Chemistry, Federal University of São Carlos, Rod. Washington Luís km 235, P. O. Box 676, 13560-970, São Carlos, SP, Brazil
| | - Ademar Wong
- Department of Chemistry, Federal University of São Carlos, Rod. Washington Luís km 235, P. O. Box 676, 13560-970, São Carlos, SP, Brazil; Department of Analytical Chemistry, Institute of Chemistry, State University of São Paulo and INCT-DATREM, 14801-970, Araraquara, SP, Brazil
| | - Thiago M Prado
- Department of Chemistry, Federal University of São Carlos, Rod. Washington Luís km 235, P. O. Box 676, 13560-970, São Carlos, SP, Brazil
| | - Elson L Fava
- Department of Chemistry, Federal University of São Carlos, Rod. Washington Luís km 235, P. O. Box 676, 13560-970, São Carlos, SP, Brazil
| | - Orlando Fatibello-Filho
- Department of Chemistry, Federal University of São Carlos, Rod. Washington Luís km 235, P. O. Box 676, 13560-970, São Carlos, SP, Brazil
| | - Maria D P T Sotomayor
- Department of Analytical Chemistry, Institute of Chemistry, State University of São Paulo and INCT-DATREM, 14801-970, Araraquara, SP, Brazil
| | - Fernando C Moraes
- Department of Chemistry, Federal University of São Carlos, Rod. Washington Luís km 235, P. O. Box 676, 13560-970, São Carlos, SP, Brazil.
| |
Collapse
|
13
|
Flexible Carbon Electrodes for Electrochemical Detection of Bisphenol-A, Hydroquinone and Catechol in Water Samples. CHEMOSENSORS 2020. [DOI: 10.3390/chemosensors8040103] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The detection of pollutant traces in the public water supply and aquifers is essential for the safety of the population. In this article, we demonstrate that a simple electrochemical procedure in acidic solution can be employed for enhancing the sensitivity of flexible screen-printed carbon electrodes (SPEs) to detect bisphenol-A (BPA), hydroquinone, and catechol, simultaneously. The SPEs were pretreated electrochemically in a H2SO4 solution, which did not affect their morphology, yielding high current signals with well separated oxidation peaks. The sensitivity values were 0.28, 0.230, and 0.056 µA L µmol−1 with detection limits of 0.12, 0.82, and 0.95 µmol L−1 for hydroquinone, catechol, and BPA, respectively. The sensors were reproducible and selective for detecting BPA in plastic cups, and with adequate specificity not to be affected by interferents from water samples. The simple, inexpensive, and flexible SPE may thus be used to detect emerging pollutants and monitor the water quality.
Collapse
|
14
|
Dang VH, Thu VT, Giang LT, Yen PTH, Phong PH, Tuan VA, Ha VTT. Multivariate calibration combined differential pulse voltammetry for simultaneous electroanalytical determination of phenolic compounds using a Fe3O4-modified carbon paste electrode. J Solid State Electrochem 2020. [DOI: 10.1007/s10008-020-04731-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
15
|
Shehata M, Fekry AM, Walcarius A. Moxifloxacin Hydrochloride Electrochemical Detection at Gold Nanoparticles Modified Screen-Printed Electrode. SENSORS 2020; 20:s20102797. [PMID: 32423013 PMCID: PMC7287685 DOI: 10.3390/s20102797] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Revised: 05/09/2020] [Accepted: 05/12/2020] [Indexed: 02/05/2023]
Abstract
It appeared that either the carbon paste or the screen-printed carbon electrodes that were modified with gold nanoparticles (AuNPs) gave rise to the largest current responses after a rapid screening of various nanomaterials as modifiers of carbon composite electrodes in view of designing an electrochemical sensor for Moxifloxacin Hydrochloride (Moxi). The screen-printed electrode (SPE) support was preferred over the carbon paste one for its ability to be used as disposable single-use sensor enabling the circumvention of the problems of surface fouling encountered in the determination of Moxi. The response of AuNPs modified SPE to Moxi was investigated by cyclic voltammetry (CV) (including the effect of the potential scan rate and the pH of the medium), chronoamperometry, and differential pulse voltammetry (DPV) after morphological and physico-chemical characterization. DPV was finally applied to Moxi detection in phosphate buffer at pH 7, giving rise to an accessible concentration window ranging between 8 µM and 0.48 mM, and the detection and quantification limits were established to be 11.6 µM and 38.6 µM, correspondingly. In order to estimate the applicability of Moxi identification scheme in actual trials, it was practiced in a human baby urine sample with excellent recoveries between 99.8 % and 101.6 % and RSDs of 1.1-3.4%, without noticeable interference.
Collapse
Affiliation(s)
- M. Shehata
- Chemistry Department, Faculty of Science, Cairo University, Giza 12613, Egypt;
| | - Amany M. Fekry
- Chemistry Department, Faculty of Science, Cairo University, Giza 12613, Egypt;
- LCPME, Université de Lorraine, CNRS, F-54000 Nancy, France
- Correspondence: (A.M.F.); (A.W.); Tel.: +202-0101-545-331 (A.M.F.); +33-3-7274-7375 (A.W.)
| | - Alain Walcarius
- LCPME, Université de Lorraine, CNRS, F-54000 Nancy, France
- Correspondence: (A.M.F.); (A.W.); Tel.: +202-0101-545-331 (A.M.F.); +33-3-7274-7375 (A.W.)
| |
Collapse
|
16
|
Raymundo-Pereira PA, Baccarin M, Oliveira ON, Janegitz BC. Thin Films and Composites Based on Graphene for Electrochemical Detection of Biologically-relevant Molecules. ELECTROANAL 2018. [DOI: 10.1002/elan.201800283] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Affiliation(s)
- Paulo A. Raymundo-Pereira
- São Carlos Institute of Physics; University of São Paulo; CP 369, CEP 13560-970 São Carlos, SP Brazil
| | - Marina Baccarin
- São Carlos Institute of Chemistry; University of São Paulo; CP 380, CEP 13566-590 São Carlos, SP Brazil
| | - Osvaldo N. Oliveira
- São Carlos Institute of Physics; University of São Paulo; CP 369, CEP 13560-970 São Carlos, SP Brazil
| | - Bruno C. Janegitz
- Department of Nature Sciences, Mathematics and Education; Federal University of São Carlos; CEP 13600-970 Araras, SP Brazil
| |
Collapse
|
17
|
Synergic effect of silver nanoparticles and carbon nanotubes on the simultaneous voltammetric determination of hydroquinone, catechol, bisphenol A and phenol. Mikrochim Acta 2017; 185:12. [PMID: 29594601 DOI: 10.1007/s00604-017-2540-5] [Citation(s) in RCA: 67] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2017] [Accepted: 11/09/2017] [Indexed: 10/18/2022]
Abstract
A glassy carbon electrode (GCE) was modified with multi-walled carbon nanotubes (MWCNT) and silver nanoparticles (AgNPs) and applied to the simultaneous determination of hydroquinone (HQ), catechol (CC), bisphenol A (BPA) and phenol by using square-wave voltammetry. The MWCNTs were deposited on the GCE and the AgNPs were then electrodeposited onto the MWCNT/GCE by the application of 10 potential sweep cycles using an AgNP colloidal suspension. The modified GCE was characterized by using SEM, which confirmed the presence of the AgNPs. The electrochemical behavior of the material was evaluated by using cyclic voltammetry, and by electrochemical impedance spectroscopy that employed hexacyanoferrate as an electrochemical probe. The results were compared to the performance of the unmodified GCE. The modified electrode has a lower charge-transfer resistance and yields an increased signal. The peaks for HQ (0.30 V), CC (0.40 V), BPA (0.74 V) and phenol (0.83 V; all versus Ag/AgCl) are well separated under optimized conditions, which facilitates their simultaneous determination. The oxidation current increases linearly with the concentrations of HQ, CC, BPA and phenol. Detection limits are in the order of 1 μM for all 4 species, and the sensor is highly stable and reproducible. The electrode was successfully employed with the simultaneous determination of HQ, CC, BPA and phenol in spiked tap water samples. Graphical abstract A glassy carbon electrode was modified with carbon nanotubes and silver nanoparticles and then successfully applied to the simultaneous determination of four phenolic compounds. The sensor showed high sensitivity in the detection of hydroquinone, catechol, bisphenol A and phenol in water samples.
Collapse
|
18
|
Raymundo-Pereira PA, Campos AM, Vicentini FC, Janegitz BC, Mendonça CD, Furini LN, Boas NV, Calegaro ML, Constantino CJ, Machado SA, Oliveira ON. Sensitive detection of estriol hormone in creek water using a sensor platform based on carbon black and silver nanoparticles. Talanta 2017; 174:652-659. [DOI: 10.1016/j.talanta.2017.06.058] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2017] [Revised: 06/20/2017] [Accepted: 06/20/2017] [Indexed: 01/09/2023]
|
19
|
Bilgin Simsek E, Saloglu D, Ozcan N, Novak I, Berek D. Carbon fiber embedded chitosan/PVA composites for decontamination of endocrine disruptor bisphenol-A from water. J Taiwan Inst Chem Eng 2017. [DOI: 10.1016/j.jtice.2016.11.008] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
20
|
Raymundo-Pereira PA, Lima ARF, Machado SAS. A nanostructured label-free platform based on an ultrathin film for ultrasensitive detection of a secosteroid hormone. RSC Adv 2016. [DOI: 10.1039/c6ra04740h] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
We report the electrocatalytic activity of perovskite-type LaNiO3-nanoxide (LN-NO) on secosteroid hormone oxidation in alkaline solution.
Collapse
Affiliation(s)
| | - Alan R. F. Lima
- Institute of Chemistry
- University of São Paulo
- 05508-000 São Paulo
- Brazil
| | - Sergio A. S. Machado
- São Carlos Institute of Chemistry
- University of São Paulo
- 13560-970 São Carlos
- Brazil
| |
Collapse
|