1
|
Zeng HH, Xu WC, Mei JB, Yang Y, Liu F, Yan GP. One-Pot Synthesis of Ce-Based Nanocomposites for Fluorescence and Colorimetric Dual-Mode Sensing Platform Construction. J Fluoresc 2024:10.1007/s10895-024-04045-5. [PMID: 39556248 DOI: 10.1007/s10895-024-04045-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2024] [Accepted: 11/12/2024] [Indexed: 11/19/2024]
Abstract
Ce-based nanomaterials have been widely studied as catalyst for their unique electronic structure, but there are few reports on the combination of cerium catalytic activity and photoluminescence performance. In this paper, by adjusting the molar ratio of Ce/P, CeO2/CePO4 nanocrystal were synthesized in one-step, which integrated the enzyme activities of CeO2 and CePO4, as well as the optical property of CePO4 together. Taking H2O2 as analyte model, utilizing the catalase oxidization activity of CeO2/CePO4, TMB molecule can be oxidized, leading to the increased absorption intensity of 652 nm, realizing the colorimetric assay of H2O2. On the other hand, using the fluorescence of CeO2/CePO4 at 338 nm as output signal, which can be quenched by H2O2 since Ce3+ ions were oxidized into Ce4+, realizing H2O2 fluorescence detection. Compared with the single-signal probe, CeO2/CePO4 provides two sensing modes of fluorescence and colorimetry for H2O2 discrimination to obtain different test results, which can be mutually verified and effectively improve the detection accuracy.
Collapse
Affiliation(s)
- Hui-Hui Zeng
- College of Materials and Chemical Engineering, Pingxiang University, Pingxiang, 337055, China.
| | - Wen-Chao Xu
- College of Materials and Chemical Engineering, Pingxiang University, Pingxiang, 337055, China
| | - Jia-Bao Mei
- College of Materials and Chemical Engineering, Pingxiang University, Pingxiang, 337055, China
| | - Yao Yang
- College of Materials and Chemical Engineering, Pingxiang University, Pingxiang, 337055, China
| | - Fang Liu
- College of Materials and Chemical Engineering, Pingxiang University, Pingxiang, 337055, China
| | - Gen-Ping Yan
- College of Materials and Chemical Engineering, Pingxiang University, Pingxiang, 337055, China.
| |
Collapse
|
2
|
Zhou Y, Li L, Tong J, Chen X, Deng W, Chen Z, Xiao X, Yin Y, Zhou Q, Gao Y, Hu X, Wang Y. Advanced nanomaterials for electrochemical sensors: application in wearable tear glucose sensing technology. J Mater Chem B 2024; 12:6774-6804. [PMID: 38920094 DOI: 10.1039/d4tb00790e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/27/2024]
Abstract
In the last few decades, tear-based biosensors for continuous glucose monitoring (CGM) have provided new avenues for the diagnosis of diabetes. The tear CGMs constructed from nanomaterials have been extensively demonstrated by various research activities in this field and are gradually witnessing their most prosperous period. A timely and comprehensive review of the development of tear CGMs in a compartmentalized manner from a nanomaterials perspective would greatly broaden this area of research. However, to our knowledge, there is a lack of specialized reviews and comprehensive cohesive reports in this area. First, this paper describes the principles and development of electrochemical glucose sensors. Then, a comprehensive summary of various advanced nanomaterials recently reported for potential applications and construction strategies in tear CGMs is presented in a compartmentalized manner, focusing on sensing properties. Finally, the challenges, strategies, and perspectives used to design tear CGM materials are emphasized, providing valuable insights and guidance for the construction of tear CGMs from nanomaterials in the future.
Collapse
Affiliation(s)
- Yue Zhou
- Department of Emergency Medicine, West China Hospital, Sichuan University, West China School of Nursing, Sichuan University, Disaster Medical Center, Sichuan University & Nursing Key Laboratory of Sichuan Province, No. 37 Guoxue Alley, Chengdu, Sichuan, 610041, China.
| | - Lei Li
- National Engineering Research Center for Biomaterials & College of Biomedical Engineering, Sichuan University, Chengdu, Sichuan, 610065, China
| | - Jiale Tong
- Department of Emergency Medicine, West China Hospital, Sichuan University, West China School of Nursing, Sichuan University, Disaster Medical Center, Sichuan University & Nursing Key Laboratory of Sichuan Province, No. 37 Guoxue Alley, Chengdu, Sichuan, 610041, China.
| | - Xiaoli Chen
- Department of Emergency Medicine, West China Hospital, Sichuan University, West China School of Nursing, Sichuan University, Disaster Medical Center, Sichuan University & Nursing Key Laboratory of Sichuan Province, No. 37 Guoxue Alley, Chengdu, Sichuan, 610041, China.
| | - Wei Deng
- Department of Orthopedics Pidu District People's Hospital, The Third Affiliated Hospital of Chengdu Medical College Chengdu, Sichuan, 611730, China
| | - Zhiyu Chen
- National Engineering Research Center for Biomaterials & College of Biomedical Engineering, Sichuan University, Chengdu, Sichuan, 610065, China
| | - Xuanyu Xiao
- National Engineering Research Center for Biomaterials & College of Biomedical Engineering, Sichuan University, Chengdu, Sichuan, 610065, China
| | - Yong Yin
- Department of Orthopedics Pidu District People's Hospital, The Third Affiliated Hospital of Chengdu Medical College Chengdu, Sichuan, 611730, China
| | - Qingsong Zhou
- Department of Orthopedics Pidu District People's Hospital, The Third Affiliated Hospital of Chengdu Medical College Chengdu, Sichuan, 611730, China
| | - Yongli Gao
- Department of Emergency Medicine, West China Hospital, Sichuan University, West China School of Nursing, Sichuan University, Disaster Medical Center, Sichuan University & Nursing Key Laboratory of Sichuan Province, No. 37 Guoxue Alley, Chengdu, Sichuan, 610041, China.
| | - Xuefeng Hu
- West China School of Basic Medical Sciences & Forensic Medicine, Sichuan University, 3-16 Renmin South Road, Chengdu, Sichuan, 610041, China.
| | - Yunbing Wang
- National Engineering Research Center for Biomaterials & College of Biomedical Engineering, Sichuan University, Chengdu, Sichuan, 610065, China
| |
Collapse
|
3
|
Yadav M, Singh G, Lata S. Polyvinylpyrrolidone/TiO 2 composites' preparation via sol-gel procedure furthered with non-enzymatic glucose sensing and antibacterial effectiveness. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:98563-98580. [PMID: 35750910 DOI: 10.1007/s11356-022-21558-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Accepted: 06/14/2022] [Indexed: 06/15/2023]
Abstract
An amperometric non-enzymatic glucose sensing based on polyvinylpyrrolidone and titanium dioxide nanocomposites (PVP-TiO2 NCs) fabricated over stainless-steel (SS) electrode was experimented. The electrode was fabricated of PVP-TiO2 NCs onto SS surface through drop casting coating. The NCs and the electrode were analyzed using Fourier transform infrared (FTIR) and UV-visible (UV-Vis) spectroscopy, X-ray diffraction spectra (XRD), X-ray photoelectron spectra (XPS), particle analyzer, scanning electron microscopy (SEM), EDS and transmission electron microscopy (TEM) and Brunauer-Emmett-Teller (BET) analysis for surface. For electrochemical investigation, cyclic voltammetry, electrochemical impedance spectra, including Nyquist plots and Bode plots, and chronoamperometry were adopted. PVP-TiO2/SS-modified electrode manifested high sensitivity of 360.13 µA/mM.cm2, lower detection limit of 756.8 µM and 0 to 13 mM linear range with regression coefficient of R2 = 0.992. The electrode exhibited high stability with good anti-interference tendency against fructose, uric acid, ascorbic acid and sucrose. The modified electrode also performed well in real sample glucose detection. Further, PVP-TiO2 NCs performed appreciably toward antibacterial studies against some Gram-positive and Gram-negative deleterious bacteria, Escherichia coli, Klebsiella pneumoniae, Staphylococcus aureus, Shigella flexneri microbes.
Collapse
Affiliation(s)
- Meena Yadav
- Department of Chemistry, Deenbandhu Chhotu Ram University of Science and Technology, Murthal, 131039, Haryana, India
| | - Geeta Singh
- Department of Biomedical Engineering, Deenbandhu Chhotu Ram University of Science and Technology, Murthal, 131039, Haryana, India
| | - Suman Lata
- Department of Chemistry, Deenbandhu Chhotu Ram University of Science and Technology, Murthal, 131039, Haryana, India.
| |
Collapse
|
5
|
Sunoqrot S, Al-Hadid A, Manasrah A, Khnouf R, Hasan Ibrahim L. Immobilization of glucose oxidase on bioinspired polyphenol coatings as a high-throughput glucose assay platform. RSC Adv 2021; 11:39582-39592. [PMID: 35492494 PMCID: PMC9044463 DOI: 10.1039/d1ra07467a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Accepted: 11/21/2021] [Indexed: 12/23/2022] Open
Abstract
Glucose oxidase (GOx) is an enzyme with important industrial and biochemical applications, particularly in glucose detection. Here we leveraged the oxidative self-polymerization phenomenon of simple polyphenols (pyrogallol or catechol) in the presence of polyethylenimine (PEI) to form adhesive coatings that enabled GOx immobilization on conventional multi-well plates. Immobilization was verified and optimized by directly measuring GOx activity inside the coated wells. Our results showed that incorporating PEI in polyphenol coatings enhanced their enzyme immobilization efficiency, with pyrogallol (PG)-based coatings displaying the greatest enzyme activity. The immobilized enzyme maintained similar affinity to glucose compared to the free enzyme. GOx-immobilized PG/PEI-coated wells exhibited intermediate recycling ability but excellent resistance to urea as a denaturing agent compared to the free enzyme. GOx-immobilized 96-well plates allowed the construction of a linear glucose calibration curve upon adding glucose standards, with a detection limit of 0.4–112.6 mg dL−1, which was comparable to commercially available enzymatic glucose assay kits. The assay platform was also capable of effectively detecting glucose in rat plasma samples. Our findings present a simple enzyme immobilization technique that can be used to construct a glucose assay platform in a convenient multi-well format for high-throughput glucose quantification. Glucose oxidase was immobilized on conventional multi-well plates via bioinspired polyphenol chemistry for convenient colorimetric quantitation of glucose.![]()
Collapse
Affiliation(s)
- Suhair Sunoqrot
- Department of Pharmacy, Faculty of Pharmacy, Al-Zaytoonah University of Jordan Amman 11733 Jordan +962 64291423 +962 64291511 ext. 197
| | - Amani Al-Hadid
- Department of Pharmacy, Faculty of Pharmacy, Al-Zaytoonah University of Jordan Amman 11733 Jordan +962 64291423 +962 64291511 ext. 197
| | - Ahmad Manasrah
- Department of Mechanical Engineering, Faculty of Engineering and Technology, Al-Zaytoonah University of Jordan Amman 11733 Jordan
| | - Ruba Khnouf
- Department of Biomedical Engineering, Faculty of Engineering, Jordan University of Science and Technology Irbid 22110 Jordan
| | - Lina Hasan Ibrahim
- Department of Pharmacy, Faculty of Pharmacy, Al-Zaytoonah University of Jordan Amman 11733 Jordan +962 64291423 +962 64291511 ext. 197
| |
Collapse
|