1
|
Çardak M, Özmen Toğay S, Ay M, Karaalioğlu O, Erol Ö, Bağcı U. Antibiotic resistance and virulence genes in Enterococcus species isolated from raw and processed seafood. JOURNAL OF FOOD SCIENCE AND TECHNOLOGY 2022; 59:2884-2893. [PMID: 35734123 PMCID: PMC9206942 DOI: 10.1007/s13197-021-05313-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Revised: 09/13/2021] [Accepted: 11/04/2021] [Indexed: 06/15/2023]
Abstract
This study evaluated the antibiotic resistance characteristics and virulence genes of enterococci isolated from raw and processed seafood sold in the Marmara Region, Turkey. In this context, the enterococcal load was determined as between 1.0 and 2.5 log CFU/g in 39 of a total of 397 samples. It was determined that 117 strains isolated from the samples belonged to Enterococcus gallinarum, E. casseliflavus, E. durans, E. faecium, and E. faecalis species. Erythromycin, tetracycline, streptomycin, and gentamicin resistance was observed, whereas the tetM, ermB, aac(6')-aph(2'')-la genes were found in a majority of the isolates. It was also determined that the isolates carried the agg2 and gelE virulence genes. When all these results are evaluated, the presence of these isolates in aquatic products may pose a risk in terms of food safety and public health.
Collapse
Affiliation(s)
- Mine Çardak
- Department of Fisheries Technology, Faculty of Applied Science at Çanakkale, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Sine Özmen Toğay
- Department of Food Engineering, Faculty of Agriculture, Bursa Uludağ University, Bursa, Turkey
| | - Mustafa Ay
- Department of Food Technology, Faculty of Applied Science at Çanakkale, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Onur Karaalioğlu
- Graduate School of Natural and Applied Sciences, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Özlem Erol
- Department of Health Services and Techniques, Vocational School of Health Services, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Ufuk Bağcı
- Department of Food Engineering, Faculty of Engineering, Trakya University, Edirne, Turkey
| |
Collapse
|
2
|
Mobasheri N, Karimi M, Hamedi J. Implementing Electric Potential Difference as a New Practical Parameter for Rapid and Specific Measurement of Minimum Inhibitory Concentration of Antibiotics. Curr Microbiol 2018; 75:1290-1298. [PMID: 29869678 DOI: 10.1007/s00284-018-1523-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2018] [Accepted: 06/01/2018] [Indexed: 11/29/2022]
Abstract
New methods to determine antimicrobial susceptibility of bacterial pathogens especially the minimum inhibitory concentration (MIC) of antibiotics have great importance in pharmaceutical industry and treatment procedures. In the present study, the MIC of several antibiotics was determined against some pathogenic bacteria using macrodilution test. In order to accelerate and increase the efficiency of culture-based method to determine antimicrobial susceptibility, the possible relationship between the changes in some physico-chemical parameters including conductivity, electrical potential difference (EPD), pH and total number of test strains was investigated during the logarithmic phase of bacterial growth in presence of antibiotics. The correlation between changes in these physico-chemical parameters and growth of bacteria was statistically evaluated using linear and non-linear regression models. Finally, the calculated MIC values in new proposed method were compared with the MIC derived from macrodilution test. The results represent significant association between the changes in EPD and pH values and growth of the tested bacteria during the exponential phase of bacterial growth. It has been assumed that the proliferation of bacteria can cause the significant changes in EPD values. The MIC values in both conventional and new method were consistent to each other. In conclusion, cost and time effective antimicrobial susceptibility test can be developed based on monitoring the changes in EPD values. The new proposed strategy also can be used in high throughput screening of biocompounds for their antimicrobial activity in a relatively shorter time (6-8 h) in comparison with the conventional methods.
Collapse
Affiliation(s)
- Nasrin Mobasheri
- Department of Microbial Biotechnology, School of Biology and Center of Excellence in Phylogeny Living Organisms, College of Science, University of Tehran, Tehran, Iran.,Microbial Technology and Products (MTP) Research Center, University of Tehran, Tehran, Iran
| | - Mehrdad Karimi
- Department of Epidemiology and Biostatistics, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
| | - Javad Hamedi
- Department of Microbial Biotechnology, School of Biology and Center of Excellence in Phylogeny Living Organisms, College of Science, University of Tehran, Tehran, Iran. .,Microbial Technology and Products (MTP) Research Center, University of Tehran, Tehran, Iran.
| |
Collapse
|
3
|
Blaschke AJ, Heyrend C, Byington CL, Fisher MA, Barker E, Garrone NF, Thatcher SA, Pavia AT, Barney T, Alger GD, Daly JA, Ririe KM, Ota I, Poritz MA. Rapid identification of pathogens from positive blood cultures by multiplex polymerase chain reaction using the FilmArray system. Diagn Microbiol Infect Dis 2012; 74:349-55. [PMID: 22999332 DOI: 10.1016/j.diagmicrobio.2012.08.013] [Citation(s) in RCA: 149] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2012] [Revised: 07/21/2012] [Accepted: 08/20/2012] [Indexed: 01/09/2023]
Abstract
Sepsis is a leading cause of death. Rapid and accurate identification of pathogens and antimicrobial resistance directly from blood culture could improve patient outcomes. The FilmArray® (FA; Idaho Technology, Salt Lake City, UT, USA) Blood Culture (BC) panel can identify >25 pathogens and 4 antibiotic resistance genes from positive blood cultures in 1 h. We compared a development version of the panel to conventional culture and susceptibility testing on 102 archived blood cultures from adults and children with bacteremia. Of 109 pathogens identified by culture, 95% were identified by FA. Among 111 prospectively collected blood cultures, the FA identified 84 (91%) of 92 pathogens covered by the panel. Among 25 Staphylococcus aureus and 21 Enterococcus species detected, FA identified all culture-proven methicillin-resistant S. aureus and vancomycin-resistant enterococci. The FA BC panel is an accurate method for the rapid identification of pathogens and resistance genes from blood culture.
Collapse
Affiliation(s)
- Anne J Blaschke
- Department of Pediatrics, University of Utah, Salt Lake City, UT, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Phoenix 100 versus Vitek 2 in the identification of gram-positive and gram-negative bacteria: a comprehensive meta-analysis. J Clin Microbiol 2011; 49:3284-91. [PMID: 21752980 DOI: 10.1128/jcm.00182-11] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Phoenix 100 and Vitek 2 (operating with the current colorimetric cards) are commonly used in hospital laboratories for rapid identification of microorganisms. The present meta-analysis aims to evaluate and compare their performance on Gram-positive and Gram-negative bacteria. The MEDLINE database was searched up to October 2010 for the retrieval of relevant articles. Pooled correct identification rates were derived from random-effects models, using the arcsine transformation. Separate analyses were conducted at the genus and species levels; subanalyses and meta-regression were undertaken to reveal meaningful system- and study-related modifiers. A total of 29 (6,635 isolates) and 19 (4,363 isolates) articles were eligible for Phoenix and colorimetric Vitek 2, respectively. No significant differences were observed between Phoenix and Vitek 2 either at the genus (97.70% versus 97.59%, P = 0.919) or the species (92.51% versus 88.77%, P = 0.149) level. Studies conducted with conventional comparator methods tended to report significantly better results compared to those using molecular reference techniques. Speciation of Staphylococcus aureus was significantly more accurate in comparison to coagulase-negative staphylococci by both Phoenix (99.78% versus 88.42%, P < 0.00001) and Vitek 2 (98.22% versus 91.89%, P = 0.043). Vitek 2 also reached higher correct identification rates for Gram-negative fermenters versus nonfermenters at the genus (99.60% versus 95.90%, P = 0.004) and the species (97.42% versus 84.85%, P = 0.003) level. In conclusion, the accuracy of both systems seems modified by underlying sample- and comparator method-related parameters. Future simultaneous assessment of the instruments against molecular comparator procedures may facilitate interpretation of the current observations.
Collapse
|
5
|
Mittman SA, Huard RC, Della-Latta P, Whittier S. Comparison of the automated Phoenix with the Vitek 2 for the identification of Streptococcus pneumoniae. Can J Microbiol 2010; 56:326-32. [PMID: 20453899 DOI: 10.1139/w10-016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Rapid and accurate identification of Streptococcus pneumoniae is a critical component in the optimal management of infected patients. The performance of the BD Phoenix Automated Microbiology System (BD Diagnostic Systems, Sparks, Md.) was evaluated for identification of S. pneumoniae (n = 311) and was compared to the Vitek 2 (bioMérieux, Marcy l'Etoile, France). Strains with discordant identification between methods were resolved with 16S rRNA gene sequencing as the gold standard. The Phoenix and the Vitek 2 correctly identified 96.8% (n = 301) and 95.2% (n = 296) of S. pneumoniae strains, respectively. Overall, there was no statistically significant difference in the performance of the 2 automated systems for the identification of S. pneumoniae in this study. The Vitek 2 mean time-to-results for all streptococcal identification was 1.5 h faster than that for the Phoenix. We conclude that the automated Phoenix and the Vitek 2 systems are comparable in their ability to identify S. pneumoniae and are preferable to the use of routine biochemical assays, which have delayed time-to-results and are not dependably accurate.
Collapse
Affiliation(s)
- Scott A Mittman
- Clinical Microbiology Service, NewYork-Presbyterian Hospital, Columbia University Medical Center, New York, NY 10032, USA
| | | | | | | |
Collapse
|
6
|
Comparison of BD phoenix to vitek 2, microscan MICroSTREP, and Etest for antimicrobial susceptibility testing of Streptococcus pneumoniae. J Clin Microbiol 2009; 47:3557-61. [PMID: 19741088 DOI: 10.1128/jcm.01137-09] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The performance of the BD Phoenix Automated Microbiology System (BD Diagnostic Systems) was compared to those of the Vitek 2 (bioMérieux), the MicroScan MICroSTREP plus (Siemens), and Etest (bioMérieux) for antibiotic susceptibility tests (AST) of 311 clinical isolates of Streptococcus pneumoniae. The overall essential agreement (EA) between each test system and the reference microdilution broth reference method for S. pneumoniae AST results was >95%. For Phoenix, the EAs of individual antimicrobial agents ranged from 90.4% (clindamycin) to 100% (vancomycin and gatifloxacin). The categorical agreements (CA) of Phoenix, Vitek 2, MicroScan, and Etest for penicillin were 95.5%, 94.2%, 98.7%, and 97.7%, respectively. The overall CA for Phoenix was 99.3% (1 very major error [VME] and 29 minor errors [mEs]), that for Vitek 2 was 98.8% (7 VMEs and 28 mEs), and those for MicroScan and Etest were 99.5% each (19 and 13 mEs, respectively). The average times to results for Phoenix, Vitek 2, and the manual methods were 12.1 h, 9.8 h, and 24 h, respectively. From these data, the Phoenix AST results demonstrated a high degree of agreement with all systems evaluated, although fewer VMEs were observed with the Phoenix than with the Vitek 2. Overall, both automated systems provided reliable AST results for the S. pneumoniae-antibiotic combinations in half the time required for the manual methods, rendering them more suitable for the demands of expedited reporting in the clinical setting.
Collapse
|
7
|
Extended-spectrum Beta-lactamase detection with different panels for automated susceptibility testing and with a chromogenic medium. J Clin Microbiol 2008; 46:3721-7. [PMID: 18845821 DOI: 10.1128/jcm.00777-08] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
Infections caused by extended-spectrum beta-lactamase (ESBL)- and ampC beta-lactamase-producing gram-negative bacteria complicate therapy and limit treatment options. Several different panels for ESBL detection with automated systems exist. In addition, a chromogenic agar medium is available for ESBL screening. We compared two automated identification and susceptibility testing systems with regard to their effectiveness in detecting ESBL production in Enterobacteriaceae: the BD Phoenix system (BD Diagnostic Systems, Sparks, MD) and the Vitek 2 system (bioMerieux, Marcy l'Etoile, France). We tested 114 strains using the Etest as the standard, various available panels for both automated systems (for BD Phoenix, the NMIC/ID-50 and NMIC/ID-70 GN Combo panels for combined identification and susceptibility testing of gram-negative bacilli, and for Vitek 2, the ID-GNB panel for identification of gram-negative bacilli and the AST-N020, AST-N041, and AST-N062 panels for susceptibility testing), and a chromogenic agar medium (bioMérieux, Marcy l'Etoile, France). PCR for common ESBL gene families (encoding TEM, SHV, OXA, and CTX-M) and for chromosomal or plasmid-mediated ampC beta-lactamase genes was conducted to complete the study design. For the tested specimens overall, the chromID ESBL agar showed the highest sensitivity (95.8%) but the lowest specificity (10.5%) compared to the sensitivity and specificity of the Etest (chosen as reference by the authors) for the detection of ESBL-producing strains. The BD Phoenix system showed sensitivities of 77.1% and 84.2% and specificities of 61.5% and 75.0%, respectively, for the NMIC/ID-50 andNMIC/ID-70 panels. The sensitivity of the Vitek 2 system ranged from 78.8% (AST-N020) to 80.6% (AST-N062) and up to 84.2% (AST-N041). The specificities of the respective panels were 50.0% (AST-N041 and AST-N062) and 55.6% (AST-N020). In conclusion, the sensitivities and specificities of ESBL detection by the different methods differ depending on the microorganisms under study.
Collapse
|
8
|
Valenza G, Ruoff C, Vogel U, Frosch M, Abele-Horn M. Microbiological evaluation of the new VITEK 2 Neisseria-Haemophilus identification card. J Clin Microbiol 2007; 45:3493-7. [PMID: 17728469 PMCID: PMC2168501 DOI: 10.1128/jcm.00953-07] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
VITEK 2 is an automated identification system for diverse bacterial and fungal species. A new card (the Neisseria-Haemophilus [NH] card) for the identification of Neisseria spp., Haemophilus spp., and other fastidious gram-negative or gram-variable microorganisms has been developed, but its performance in a routine clinical laboratory has not yet been evaluated. In this study, a total of 188 bacterial strains belonging to the genera Actinobacillus, Campylobacter, Capnocytophaga, Cardiobacterium, Eikenella, Gardnerella, Haemophilus, Kingella, Moraxella, and Neisseria were investigated. The NH card was able to identify 171 strains (91%) correctly without the need for extra tests; one strain (0.5%) was misidentified, and five strains (2.7%) could not be classified. Eleven strains (5.8%) were identified with a low level of discrimination, and simple additional tests were required to increase the correct-identification rate to 96.8%. The results were available within 6 h. Based on these results, the new VITEK 2 NH card appears to be a good method for the identification of diverse groups of fastidious organisms, which would otherwise require testing with multiple systems. However, more work is needed to evaluate the performance of VITEK 2 with regard to Haemophilus, Actinobacillus, Cardiobacterium, Eikenella, and Kingella bacteria because of the insufficient number of strains tested in this study. Moreover, further reduction of the detection time would be desirable.
Collapse
Affiliation(s)
- Giuseppe Valenza
- Institute of Hygiene and Microbiology, University of Würzburg, Josef-Schneider-Str 2/E1, 97080, Würzburg, Germany.
| | | | | | | | | |
Collapse
|