Yi Y, Li L, Li J, Shu X, Kang H, Wang C, Chang Y. Use of lasers in gastrointestinal endoscopy: a review of the literature. Lasers Med Sci 2023; 38:97. [PMID: 37022519 DOI: 10.1007/s10103-023-03755-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Accepted: 03/27/2023] [Indexed: 04/07/2023]
Abstract
Lasers emit highly directional light with consistent wavelengths, and recent studies have demonstrated their successful applications in gastrointestinal endoscopic therapy. Although argon plasma coagulators (APC) became the preferred treatment option due to improved safety profile and lower costs, advancements in laser and optic fiber manufacturing have reignited interest in laser treatment. Different laser wavelengths have distinct features and applications based on their tissue absorption coefficient. Lasers with shorter wavelengths are effectively absorbed by hemoglobin, resulting in a good coagulation effect. Near-infrared lasers have ability to ablate solid tumors, while far-infrared lasers can make precise mucosal incisions without causing peripheral thermal damage. Lasers have proven to be highly applicable to endoscopy devices such as endoscopes, endoscopic ultrasound (EUS), double-balloon enteroscopes (DBE), and endoscopic retrograde cholangiopancreatography (ERCP), making them a potent tool to enhance the effectiveness of endoscopic treatments with minimal adverse events. This review aims to help readers understand the applications and effectiveness of lasers in gastrointestinal endoscopy, with the potential to promote the development and application of laser technology in the medical field.
Collapse
Affiliation(s)
- Yun Yi
- Department of Gastroenterology, Zhongnan Hospital of Wuhan University, Wuhan, 430071, China
- Hubei Clinical Center and Key Laboratory of Intestinal and Colorectal Diseases, Wuhan, China
| | - Lurao Li
- Department of Gastroenterology, Zhongnan Hospital of Wuhan University, Wuhan, 430071, China
- Hubei Clinical Center and Key Laboratory of Intestinal and Colorectal Diseases, Wuhan, China
| | - Jianghui Li
- Department of Gastroenterology, Zhongnan Hospital of Wuhan University, Wuhan, 430071, China
- Hubei Clinical Center and Key Laboratory of Intestinal and Colorectal Diseases, Wuhan, China
| | - Xiawen Shu
- Department of Gastroenterology, Zhongnan Hospital of Wuhan University, Wuhan, 430071, China
- Hubei Clinical Center and Key Laboratory of Intestinal and Colorectal Diseases, Wuhan, China
| | - Hui Kang
- Department of Gastroenterology, Zhongnan Hospital of Wuhan University, Wuhan, 430071, China
- Hubei Clinical Center and Key Laboratory of Intestinal and Colorectal Diseases, Wuhan, China
| | - Chun Wang
- Department of Gastroenterology, Zhongnan Hospital of Wuhan University, Wuhan, 430071, China
- Hubei Clinical Center and Key Laboratory of Intestinal and Colorectal Diseases, Wuhan, China
| | - Ying Chang
- Department of Gastroenterology, Zhongnan Hospital of Wuhan University, Wuhan, 430071, China.
- Hubei Clinical Center and Key Laboratory of Intestinal and Colorectal Diseases, Wuhan, China.
| |
Collapse
|
2
|
Ex Vivo Exposure to Soft Biological Tissues by the 2-μm All-Fiber Ultrafast Holmium Laser System. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12083825] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
We present the results of ex vivo exposure by an ultrafast all-fiber Holmium laser system to porcine longissimus muscle tissues. A simple Ho-doped laser system generated ultrashort pulsed radiation with less than 1 ps pulse width and a repetition rate of 20 MHz at a central wavelength of 2.06 μm. Single-spot ex vivo experiments were performed at an average power of 0.3 W and different exposure times of 5, 30 and 60 s, varying the total applied energy in the range of 1.5–18 J. Evaluation of laser radiation exposure was performed according to the depth and diameter of coagulation zones, ablation craters and thermal damage zones during the morphological study. Exposure by ultrashort pulsed radiation with an average power of 0.3 W showed destructive changes in the muscle tissue after 5 s and nucleation of an ablative crater. The maximum ablation efficiency was about 28% at the ablation depth and diameter of 180 μm and 500 μm, respectively. The continuous-wave radiation impact at the same parameters resulted only in heating of the near-muscular tissue, without ablation and coagulation traces. Exposure to tissue with an average power at 0.3 W of ultrashort pulsed radiation led, within 30 and 60 s, to similar results as caused by 0.5 W of continuous-wave radiation, although with less carbonization formation.
Collapse
|
3
|
Ex-Vivo Exposure on Biological Tissues in the 2-μm Spectral Range with an All-Fiber Continuous-Wave Holmium Laser. PHOTONICS 2021. [DOI: 10.3390/photonics9010020] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
We present the results on the interaction of an all-fiber Holmium-doped laser CW radiation at a wavelength of 2100 nm with soft tissues and compare it with the other results obtained by the most used solid-state laser systems. Ex-vivo single spot experiments were carried out on the porcine longissimus muscles by varying the laser impact parameters in a wide range (average output power 0.3, 0.5 and 1.1 W; exposure time 5, 30 and 60 s). Evaluation of the laser radiation exposure was carried out by the size of coagulation and ablation zones on the morphological study. Exposure to a power of 0.3 W (1.5–18 J of applied energy) caused only reversible changes in the tissues. The highest applied energy of 66 J for 1.1 W and a 60-s exposure resulted in a maximum ablation depth of approximately 1.2 mm, with an ablation efficiency of 35%. We have shown that it is not necessary to use high powers of CW radiation, such as 5–10 W in the solid-state systems to provide the destructive effects. Similar results can be achieved at lower powers using the simple all-fiber Holmium laser based on the standard single-mode fiber, which could provide higher power densities and be more convenient to manufacture and use. The obtained results may be valuable as an additional experimental point in the field of existing results, which in the future will allow one to create a simple optimal laser system for medical purposes.
Collapse
|
4
|
Experimental Investigation of Double-End Pumped Tm, Ho: GdVO4 Laser at Cryogenic Temperature. CRYSTALS 2021. [DOI: 10.3390/cryst11070798] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
We describe comparatively cryogenically cooled Tm, Ho: GdVO4 lasers with an emission wavelength of 2.05 μm under continuous wave and pulse operating mode. By varying the transmittance of output couplers to be 0.40 for a continuous wave laser, the maximum output power of 7.4 W was generated with a slope efficiency of 43.3% when the absorbed pump power was increased to 18.7 W. For passively Q-switched lasers, the output characteristics were researched through altering pump mode radius. When the pump mode radius focused into the Tm, Ho: GdVO4 center equaled near 600 μm, the peak power was increased to be the maximum value of 9.9 kW at the absorbed pump power of 11.8 W. The pulse energy of 0.39 mJ was achieved at the same absorbed pump power with repetition of 5.7 kHz.
Collapse
|