1
|
Soroko-Dubrovina M, Zielińska P, Dudek KD, Śniegucka K, Nawrot K. Thermal Effects of High-Intensity Laser Therapy on the Temporomandibular Joint Area in Clinically Healthy Racehorses-A Pilot Study. Animals (Basel) 2025; 15:1426. [PMID: 40427303 PMCID: PMC12108243 DOI: 10.3390/ani15101426] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2025] [Revised: 04/24/2025] [Accepted: 05/13/2025] [Indexed: 05/29/2025] Open
Abstract
The aim of the present study was to assess the thermal effects of high-intensity laser therapy (HILT) on the temporomandibular joint (TMJ) area of clinically healthy Thoroughbred racehorses. The study was conducted on 21 clinically healthy Thoroughbreds in regular training. The horses were subjected to thermographic examinations before and immediately after a HILT session to measure changes in the body surface temperature in the TMJ area. The left TMJ was subjected to therapy, while the contralateral joint served as a control. Statistically significant differences in the body surface temperature in the TMJ area-before and after HILT-were found (p < 0.001). The body surface temperature of the area examined was higher by an average of 2.0 °C after HILT, compared to the temperature measured before HILT. The results prove the thermal effect of HILT in the TMJ area, which can be helpful in determining the appropriate and safe HILT parameters for the treatment of TMJ injuries and inflammation.
Collapse
Affiliation(s)
- Maria Soroko-Dubrovina
- Institute of Animal Breeding, Wroclaw University of Environmental and Life Sciences, Chelmonskiego 38C, 51-160 Wroclaw, Poland; (K.Ś.); (K.N.)
| | - Paulina Zielińska
- Department of Surgery, Wroclaw University of Environmental and Life Sciences, pl. Grunwaldzki 51, 50-366 Wroclaw, Poland;
| | - Krzysztof D. Dudek
- Faculty of Mechanical Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland;
| | - Karolina Śniegucka
- Institute of Animal Breeding, Wroclaw University of Environmental and Life Sciences, Chelmonskiego 38C, 51-160 Wroclaw, Poland; (K.Ś.); (K.N.)
| | - Karolina Nawrot
- Institute of Animal Breeding, Wroclaw University of Environmental and Life Sciences, Chelmonskiego 38C, 51-160 Wroclaw, Poland; (K.Ś.); (K.N.)
| |
Collapse
|
2
|
Buduru S, Hafidi S, Almășan O, Manziuc M, Tăut M, Buduru R, Nechita VI, Kui A, Chisnoiu A, Bacali C. Digital Condylar Parameter Assessment Using Cadiax ® 2 and Modjaw ®. Dent J (Basel) 2024; 12:369. [PMID: 39590419 PMCID: PMC11592875 DOI: 10.3390/dj12110369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2024] [Revised: 11/13/2024] [Accepted: 11/15/2024] [Indexed: 11/28/2024] Open
Abstract
Background: The main aim of this research was to assess the reliability of two systems designed specifically for condylar movement recording using condylar slope and Bennett angle information. The objectives were to evaluate the validity of two subsequent null hypotheses: (1) there is no significant difference between the measurements of condylar slope and Bennett angle taken at T0 (initial) and T1 (after one week) using the same equipment; (2) there is no notable difference in the values of the condylar slope and Bennett angle measurements obtained using Modjaw and Cadiax 2. Methods: An observational, descriptive, and prospective study was conducted with a selected group of 25 individuals (13 females and 12 males) aged between 22 and 27. Results: The results of Cadiax 2 and Modjaw showed excellent measurement repeatability for both parameters, with intraclass correlation coefficients (ICC) above 0.90, indicating excellent reliability between T0 and T1, both at 3 mm and 5 mm of displacement. Modjaw had an overall average value relatively higher than Cadiax 2, even though Modjaw's condylar slope at 5mm had a significantly lower average value (37.4 ± 6.31) with an interval of 24.5-48.1, which was lower than Cadiax 2 (48.4 ± 10.6) with an interval of 30.5-68.5. Regarding the primary aim, it can be stated that both Modjaw and Cadiax 2 demonstrated excellent repeatability on their own, demonstrating robust reliability since there was no discernible difference between the T0 and T1 measurements. On the contrary, analyses of the two devices' measured values for the secondary aim showed a considerable difference. Conclusions: Even though each device is reliable on its own, the absolute values that are obtained are different. Technological differences between the systems may account for these variations.
Collapse
Affiliation(s)
- Smaranda Buduru
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 400006 Cluj-Napoca, Romania
| | - Sara Hafidi
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 400006 Cluj-Napoca, Romania
| | - Oana Almășan
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 400006 Cluj-Napoca, Romania
| | - Manuela Manziuc
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 400006 Cluj-Napoca, Romania
| | - Manuela Tăut
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 400006 Cluj-Napoca, Romania
| | - Rareș Buduru
- Stomestet Dental Clinic, 400658 Cluj-Napoca, Romania
| | - Vlad-Ionuț Nechita
- Department of Medical Education, Medical Informatics and Biostatistics, Iuliu Hatieganu University of Medicine and Pharmacy, 400029 Cluj-Napoca, Romania
| | - Andreea Kui
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 400006 Cluj-Napoca, Romania
| | - Andreea Chisnoiu
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 400006 Cluj-Napoca, Romania
| | - Cecilia Bacali
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 400006 Cluj-Napoca, Romania
| |
Collapse
|