1
|
Ferrari D, Peponis T, Violante T, Cheng JN, Perry WR, Larson DW, Behm KT. Single-port robotic transanal minimally invasive surgery (SPR-TAMIS): another giant leap forward? Colorectal Dis 2024. [PMID: 39635954 DOI: 10.1111/codi.17252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Revised: 09/23/2024] [Accepted: 11/02/2024] [Indexed: 12/07/2024]
Abstract
AIM Minimally invasive transanal platforms are now the standard of care for select low-risk rectal tumours. However, existing platforms come with persistent technical challenges. The da Vinci SP Surgical System™ offers a new alternative designed to work effectively in narrow spaces. This technology has the potential to enhance the feasibility and proximal extent of complex transanal resections. This study aimed to describe the morbidity and technical success in patients undergoing single-port robotic transanal minimally invasive surgery (SPR-TAMIS). Secondary outcomes include rates of local recurrence. METHODS A retrospective analysis was conducted on all patients who underwent SPR-TAMIS at our institution between February 2019 and December 2023. RESULTS The study included 31 patients (19 men, 12 women) with a mean age of 61 ± 13.3 years. The average tumour distance from the anal verge was 10 cm. Thirty patients completed SPR-TAMIS, with one patient requiring conversion to robotic sigmoidectomy due to location in the mid-sigmoid colon. The mean operating time was 106 ± 42 min. Twenty-eight out of 30 patients underwent full-thickness excision and all but two were successfully closed. All specimens were resected intact, and margins were negative in 93.5% of cases. The average tumour size was 13 ± 34 cm2, with 13 lesions classified as adenomas and 16 as adenocarcinomas. All patients who did not undergo associated procedures were discharged on the day of surgery. Two patients experienced 30-day morbidity. At a mean follow-up of 18 months (± 13), no local or systemic recurrences were identified. CONCLUSION SPR-TAMIS for excision of low-risk rectal tumours is associated with high rates of technical success and low 30-day morbidity. Further research is needed to compare SPR-TAMIS with other techniques to determine potential advantages over current transanal platforms.
Collapse
Affiliation(s)
- Davide Ferrari
- Department of Colon and Rectal Surgery, Mayo Clinic, Rochester, Minnesota, USA
- General Surgery Residency Programme, University of Milan, Milan, Italy
| | - Thomas Peponis
- Department of Colon and Rectal Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | - Tommaso Violante
- Department of Colon and Rectal Surgery, Mayo Clinic, Rochester, Minnesota, USA
- General Surgery Residency Programme, University of Bologna, Bologna, Italy
| | - Jyi Ng Cheng
- Department of Colon and Rectal Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | - William R Perry
- Department of Colon and Rectal Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | - David W Larson
- Department of Colon and Rectal Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | - Kevin T Behm
- Department of Colon and Rectal Surgery, Mayo Clinic, Rochester, Minnesota, USA
| |
Collapse
|
2
|
Woo JS, Cho MJ, Park IK, Im YC, Kim GY, Park DJ, Yang S. Initial case series experience with robotic-assisted transanal minimally invasive surgery performed with da Vinci single-port system for the excision of rectal cancer. Surg Endosc 2024; 38:6762-6770. [PMID: 39160313 DOI: 10.1007/s00464-024-11142-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2024] [Accepted: 08/01/2024] [Indexed: 08/21/2024]
Abstract
BACKGROUND Transanal minimally invasive surgery (TAMIS) is widely used for rectal lesion excision. Robot-assisted TA TAMIS (R-TAMIS) may improve surgical ergonomics. The introduction of the da Vinci Single-Port (SP) robot, designed for endoluminal surgery, has brought new possibilities. Our primary objective herein was to assess the technical and oncological feasibility and efficacy of Single-port robotic TAMIS (SPR-TAMIS) in rectal cancer excision. The secondary objective was to analyze the perioperative outcomes. MATERIALS AND METHODS We included 14 consecutive patients with rectal cancer who underwent SPR-TAMIS between April 2021 and February 2023. Patient data, surgical details, and clinical outcome data were collected to assess the safety and feasibility of SPR-TAMIS. RESULTS The median participant age was 72 years, and full-thickness excision was performed without specimen fragmentation in all cases. The median tumor diameter was 2.7 cm, positioned between 10 cm proximally and 7 cm distally from the anal verge. Negative margins were achieved in 93% of cases, with one case requiring further resection. The median operative time was 175 min, and the median hospital stay was 5 days. No intraoperative conversion from SPR-TAMIS to laparoscopic or conventional transanal excision was required. No mortalities or major postoperative complications occurred; however, one patient (7.1%) experienced minor morbidity manifesting as wound dehiscence (Clavien-Dindo grade I). No recurrence was observed during the 24-month follow-up. CONCLUSIONS In our early experience, SPR-TAMIS is a safe and feasible surgery for selected early stage rectal cancers, offering enhanced visualization and stable maneuverability transanally. This platform may have potential advantages for the excision of larger or more proximal lesions.
Collapse
Affiliation(s)
- Ji Su Woo
- Department of Surgery, University of Ulsan College of Medicine, Ulsan University Hospital, 15, Daehakbyeongwon-ro, Dong-gu, Ulsan, South Korea
| | - Min Jeng Cho
- Department of Surgery, University of Ulsan College of Medicine, Ulsan University Hospital, 15, Daehakbyeongwon-ro, Dong-gu, Ulsan, South Korea
| | - In Kyu Park
- Department of Surgery, University of Ulsan College of Medicine, Ulsan University Hospital, 15, Daehakbyeongwon-ro, Dong-gu, Ulsan, South Korea
| | - Yeong Cheol Im
- Department of Surgery, University of Ulsan College of Medicine, Ulsan University Hospital, 15, Daehakbyeongwon-ro, Dong-gu, Ulsan, South Korea
| | - Gyu Yeol Kim
- Department of Surgery, University of Ulsan College of Medicine, Ulsan University Hospital, 15, Daehakbyeongwon-ro, Dong-gu, Ulsan, South Korea
| | - Dong Jin Park
- Department of Surgery, University of Ulsan College of Medicine, Ulsan University Hospital, 15, Daehakbyeongwon-ro, Dong-gu, Ulsan, South Korea
| | - Songsoo Yang
- Department of Surgery, University of Ulsan College of Medicine, Ulsan University Hospital, 15, Daehakbyeongwon-ro, Dong-gu, Ulsan, South Korea.
| |
Collapse
|
3
|
Picciariello A, Annicchiarico A, Gallo G, Dezi A, Grossi U. Evaluation of the da Vinci single-port system in colorectal cancer surgery: a scoping review. Updates Surg 2024; 76:2515-2520. [PMID: 39369142 DOI: 10.1007/s13304-024-02014-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2024] [Accepted: 09/25/2024] [Indexed: 10/07/2024]
Abstract
Minimally invasive surgery for the treatment of colon and rectal cancer has gained popularity due to its association with reduced postoperative pain, shorter hospital stays, and quicker recovery. The Da Vinci Single-Port (SP) System combines single-port laparoscopy with robotic assistance. This scoping review aims to evaluate the safety and short-term postoperative outcomes of utilizing the Da Vinci SP platform in colorectal cancer surgery. A scoping review was conducted adhering to the PRISMA-ScR guidelines. Data were collected from PubMed, Embase, and the Web of Science Library as of December 22, 2023. Studies were screened and selected based on predefined criteria, focusing on the application of the SP robotic system in colorectal procedures. Data extraction included demographics, surgical details, intraoperative and postoperative outcomes. A narrative summary of the results was provided due to the heterogeneity in study designs. From an initial 2312 articles, 22 studies were selected for analysis, encompassing 465 patients undergoing robotic SP colorectal surgeries. Of these, 384 (82.6%) had a cancer diagnosis. The median age was 65 years, with approximately 60% being male. The median operative time was 225 min, with docking times averaging 12-20 min. Conversion to multi-port laparoscopy occurred in 4.2% of cases, with no conversions to open surgery. Mean intraoperative blood loss ranged from 50 to 150 ml. The mean number of lymph nodes retrieved ranged from 15 to 28. A diverting ileostomy was constructed in 20.3% of patients. Median times to flatus and soft diet were 2.5 and 3 days, respectively, with hospital stays ranging from 3 to 11 days. Perioperative complications occurred in 15.1% of patients, including wound infections (5.1%), anastomotic leakage (3.7%), and postoperative ileus (2.8%). Negative margin status (R0 resection) was achieved in 95% of cases. The Da Vinci SP robotic platform demonstrates promising safety and effectiveness in colorectal cancer surgery. It achieves high rates of successful oncological resection, adequate lymph node retrieval, and minimal intraoperative blood loss. Postoperative outcomes indicate quicker recovery times and manageable complication rates. However, longer follow-up studies are necessary to fully assess recurrence rates and long-term survival benefits associated with this innovative surgical approach.
Collapse
Affiliation(s)
| | - Alfredo Annicchiarico
- Department of Medicine and Surgery, University of Parma, Parma, Italy
- Department of General Surgery, Vaio Hospital, Fidenza, Italy
| | - Gaetano Gallo
- Department of Surgery, La Sapienza" University of Rome, Rome, Italy
| | - Agnese Dezi
- Department of Precision and Regenerative Medicine and Ionian Area, University Aldo Moro of Bari, Piazza G. Cesare, 11, 70124, Bari, Italy.
| | - Ugo Grossi
- Department of Surgery, Oncology and Gastroenterology-DiSCOG, University of Padova, Padua, Italy
| |
Collapse
|
4
|
O'Sullivan NJ, Temperley HC, Larkin J, McCormick JJ, Rausa E, McCormick P, Heriot A, Mehigan BJ, Warrier S, Kelly ME. Robotic transanal minimally invasive surgery (R-TAMIS): current evidence in the treatment of early rectal neoplasia. Int J Colorectal Dis 2024; 39:71. [PMID: 38724801 PMCID: PMC11082025 DOI: 10.1007/s00384-024-04645-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 05/02/2024] [Indexed: 05/12/2024]
Abstract
INTRODUCTION Robotic transanal minimally invasive surgery (R-TAMIS) was introduced in 2012 for the excision of benign rectal polyps and low grade rectal cancer. Ergonomic improvements over traditional laparoscopic TAMIS (L-TAMIS) include increased dexterity within a small operative field, with possibility of better surgical precision. We aim to collate the existing data surrounding the use of R-TAMIS to treat rectal neoplasms from cohort studies and larger case series, providing a foundation for future, large-scale, comparative studies. METHODS Medline, EMBASE and Web of Science were searched as part of our review. Randomised controlled trials (RCTs), cohort studies or large case series (≥ 5 patients) investigating the use of R-TAMIS to resect rectal neoplasia (benign or malignant) were eligible for inclusion in our analysis. Quality assessment of included studies was performed via the Newcastle Ottawa Scale (NOS) risk of bias tool. Outcomes extracted included basic participant characteristics, operative details and histopathological/oncological outcomes. RESULTS Eighteen studies on 317 participants were included in our analysis. The quality of studies was generally satisfactory. Overall complication rate from R-TAMIS was 9.7%. Clear margins (R0) were reported in 96.2% of patients. Local recurrence (benign or malignant) occurred in 2.2% of patients during the specified follow-up periods. CONCLUSION Our review highlights the current evidence for R-TAMIS in the local excision of rectal lesions. While R-TAMIS appears to have complication, margin negativity and recurrence rates superior to those of published L-TAMIS series, comparative studies are needed.
Collapse
Affiliation(s)
- Niall J O'Sullivan
- Department of Radiology, St. James's Hospital, Dublin, Ireland.
- School of Medicine, Trinity College Dublin, Dublin, Ireland.
- The National Centre for Advanced Medical Imaging (CAMI), St. James's Hospital, Dublin, Ireland.
| | - Hugo C Temperley
- Department of Radiology, St. James's Hospital, Dublin, Ireland
- School of Medicine, Trinity College Dublin, Dublin, Ireland
| | - John Larkin
- Department of Surgery, St. James's Hospital, Dublin, Ireland
| | - Jacob J McCormick
- Department of Surgery, Peter MacCallum Cancer Centre, Melbourne, 3000, Australia
| | - Emanuele Rausa
- Unit of Hereditary Digestive Tract Tumours, Fondazione IRCCS Istituto Nazionale Dei Tumori, Milan, Italy
| | - Paul McCormick
- Department of Surgery, St. James's Hospital, Dublin, Ireland
| | - Alexander Heriot
- Department of Surgery, Peter MacCallum Cancer Centre, Melbourne, 3000, Australia
| | - Brian J Mehigan
- Department of Surgery, St. James's Hospital, Dublin, Ireland
| | - Satish Warrier
- Department of Surgery, Peter MacCallum Cancer Centre, Melbourne, 3000, Australia
| | - Michael E Kelly
- School of Medicine, Trinity College Dublin, Dublin, Ireland
- Department of Surgery, St. James's Hospital, Dublin, Ireland
- Trinity St. James Cancer Institute, Dublin, Ireland
| |
Collapse
|
5
|
Marchegiani F, Siragusa L, Zadoroznyj A, Laterza V, Mangana O, Schena CA, Ammendola M, Memeo R, Bianchi PP, Spinoglio G, Gavriilidis P, de’Angelis N. New Robotic Platforms in General Surgery: What's the Current Clinical Scenario? MEDICINA (KAUNAS, LITHUANIA) 2023; 59:1264. [PMID: 37512075 PMCID: PMC10386395 DOI: 10.3390/medicina59071264] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 07/01/2023] [Accepted: 07/04/2023] [Indexed: 07/30/2023]
Abstract
Background and Objectives: Robotic surgery has been widely adopted in general surgery worldwide but access to this technology is still limited to a few hospitals. With the recent introduction of new robotic platforms, several studies reported the feasibility of different surgical procedures. The aim of this systematic review is to highlight the current clinical practice with the new robotic platforms in general surgery. Materials and Methods: A grey literature search was performed on the Internet to identify the available robotic systems. A PRISMA compliant systematic review was conducted for all English articles up to 10 February 2023 searching the following databases: MEDLINE, EMBASE, and Cochrane Library. Clinical outcomes, training process, operating surgeon background, cost-analysis, and specific registries were evaluated. Results: A total of 103 studies were included for qualitative synthesis after the full-text screening. Of the fifteen robotic platforms identified, only seven were adopted in a clinical environment. Out of 4053 patients, 2819 were operated on with a new robotic device. Hepatopancreatobiliary surgery specialty performed the majority of procedures, and the most performed procedure was cholecystectomy. Globally, 109 emergency surgeries were reported. Concerning the training process, only 45 papers reported the background of the operating surgeon, and only 28 papers described the training process on the surgical platform. Only one cost-analysis compared a new robot to the existing reference. Two manufacturers promoted a specific registry to collect clinical outcomes. Conclusions: This systematic review highlights the feasibility of most surgical procedures in general surgery using the new robotic platforms. Adoption of these new devices in general surgery is constantly growing with the extension of regulatory approvals. Standardization of the training process and the assessment of skills' transferability is still lacking. Further studies are required to better understand the real clinical and economical benefit.
Collapse
Affiliation(s)
- Francesco Marchegiani
- Unit of Colorectal and Digestive Surgery, DIGEST Department, Beaujon University Hospital, AP-HP, University of Paris Cité, Clichy, 92110 Paris, France; (F.M.)
| | - Leandro Siragusa
- Department of Surgical Sciences, University of Rome “Tor Vergata”, Viale Oxford 81, 00133 Rome, Italy
| | - Alizée Zadoroznyj
- Unit of Colorectal and Digestive Surgery, DIGEST Department, Beaujon University Hospital, AP-HP, University of Paris Cité, Clichy, 92110 Paris, France; (F.M.)
| | - Vito Laterza
- Unit of Colorectal and Digestive Surgery, DIGEST Department, Beaujon University Hospital, AP-HP, University of Paris Cité, Clichy, 92110 Paris, France; (F.M.)
| | - Orsalia Mangana
- Unit of Colorectal and Digestive Surgery, DIGEST Department, Beaujon University Hospital, AP-HP, University of Paris Cité, Clichy, 92110 Paris, France; (F.M.)
| | - Carlo Alberto Schena
- Unit of Colorectal and Digestive Surgery, DIGEST Department, Beaujon University Hospital, AP-HP, University of Paris Cité, Clichy, 92110 Paris, France; (F.M.)
| | - Michele Ammendola
- Science of Health Department, Digestive Surgery Unit, University “Magna Graecia” Medical School, 88100 Catanzaro, Italy
| | - Riccardo Memeo
- Unit of Hepato-Pancreato-Biliary Surgery, General Regional Hospital “F. Miulli”, 70021 Acquaviva delle Fonti, Italy
| | - Paolo Pietro Bianchi
- Division of General and Robotic Surgery, Department of Health Sciences, San Paolo Hospital, University of Milan, 20142 Milan, Italy
| | - Giuseppe Spinoglio
- Research Institute Against Digestive Cancer (IRCAD), 67000 Strasbourg, France
| | - Paschalis Gavriilidis
- Department of Surgery, Saint Helena General Hospital, Jamestown, Saint Helena STHL 1ZZ, South Atlantic Ocean, UK
| | - Nicola de’Angelis
- Unit of Colorectal and Digestive Surgery, DIGEST Department, Beaujon University Hospital, AP-HP, University of Paris Cité, Clichy, 92110 Paris, France; (F.M.)
| |
Collapse
|
6
|
Gao M, Yang W. Effects of Citrus aurantium L. on Gastrointestinal Motility and Gastric Cancer Cell Proliferation. Cancer Biother Radiopharm 2023; 38:111-115. [PMID: 33112653 DOI: 10.1089/cbr.2020.4267] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
Background: To research the impact of a Chinese traditional medicine (Citrus aurantium L.) on gastric cancer proliferation and mice gastrointestinal motility. Materials and Methods: The intestinal transit rates (ITRs) and gastric emptying (GE) values in mice with experimentally induced gastrointestinal motility dysfunction (GMD) and in normal mice were calculated to research the in vivo influences of C. aurantium L. on gastrointestinal motility. CCK-8 was used to examined the effect of C. aurantium L. on gastric cancer proliferation. Results: The GE and ITR values were dose-dependently and notably added by C. aurantium L. in normal ICR mice (with 1 g/kg C. aurantium L., ITR values: 53.3% ± 0.8% versus 64.3% ± 0.9% and 53.3% ± 0.8% versus 79.8% ± 2.0%, p < 0.01; GE values: 59.3% ± 0.8% versus 70.1% ± 1.9% and 59.9% ± 0.8% versus 69.9% ± 2.1%, p < 0.01). Compared with the normal mice, the GMD mice's ITRs were notably declined; however, C. aurantium L. could dose-dependently and significantly reverse it. In addition, in the model of delayed GE induced by loperamide and cisplatin, C. aurantium L. administration reversed the GE deficit. Furthermore, C. aurantium L. significantly reduced gastric cancer proliferation. Conclusion: The results indicate that C. aurantium L. could become a new drug for gastrointestinal prokinetic and gastric cancer therapy.
Collapse
Affiliation(s)
- Meng Gao
- Key Laboratory of Modern Preparation of Traditional Chinese Medicine of Ministry of Education, School of Chinese Medicine, Jiangxi University of Traditional Chinese Medicine, Nanchang, China
| | - Wuliang Yang
- Key Laboratory of Modern Preparation of Traditional Chinese Medicine of Ministry of Education, School of Chinese Medicine, Jiangxi University of Traditional Chinese Medicine, Nanchang, China
| |
Collapse
|
7
|
Robot-assisted TAMIS: a systematic review of feasibility and outcomes. Surg Endosc 2023; 37:3398-3409. [PMID: 36707419 PMCID: PMC9882737 DOI: 10.1007/s00464-022-09853-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 12/27/2022] [Indexed: 01/28/2023]
Abstract
BACKGROUND In the advancement of transanal local excision, robot-assisted transanal minimal invasive surgery is the newest development. In the confined area of the rectum, robot-assisted surgery should, theoretically, be superior due to articulated utensils, video enhancement, and tremor reduction, however, this has not yet been investigated. The aim of this study was to review the evidence reported to-date on experience of using robot-assisted transanal minimal invasive surgery for treatment of rectal neoplasms. METHODS A comprehensive literature search of Embase and PubMed from May to August 2021were performed. Studies including patients diagnosed with rectal neoplasia or benign polyps who underwent robot-assisted transanal minimal invasive surgery were included. All studies were assessed for risk of bias through assessment tools. Main outcome measures were feasibility, excision quality, and complications. RESULTS Twenty-five studies with a total of 322 local excisions were included. The studies included were all retrospective, primarily case-reports, -series, and cohort studies. The median distance from the anal verge ranged from 3.5 to 10 cm and the median size was between 2.5 and 5.3 cm. Overall, 4.6% of the resections had a positive resection margin. The overall complication rate was at 9.5% with severe complications (Clavien-Dindo score III) at 0.9%. CONCLUSION Based on limited, retrospective data, with a high risk of bias, robot-assisted transanal minimal invasive surgery seems feasible and safe for local excisions in the rectum.
Collapse
|
8
|
Park J, Kang LK, Kim K, Bae JS, Kim JS. The learning curve for single-port transaxillary robotic thyroidectomy (SP-TART): experience through initial 50 cases of lobectomy. Updates Surg 2022; 75:691-700. [PMID: 36536189 DOI: 10.1007/s13304-022-01445-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Accepted: 12/12/2022] [Indexed: 12/23/2022]
Abstract
The new da Vinci® single-port (SP) robotic system, which utilizes a smaller incision and work space compared to the previous versions, is suitable for thyroidectomy. This study aimed to evaluate the learning curve for SP transaxillary robotic thyroidectomy (SP-TART) in a single-center. Fifty consecutive patients who underwent SP-TART between October 2021 and April 2022 in Seoul St. Mary's Hospital in Seoul, Korea, were included in this retrospective analysis. We examined the clinicopathological characteristics and short-term surgical outcomes and assessed the learning curve for SP-TART using cumulative summation analysis. The mean operation time was 57.8 ± 14.1 min, and the mean tumor size was 1.0 ± 0.7 (range, 0.3-3.7) cm. The patients were discharged approximately 2 days after surgery, and only two (4%) patients developed postoperative complications, including drainage-site bleeding and surgical site infection. Risk factors for long operation time were thyroiditis, amount of blood loss, and lymph node metastasis. The learning curve for SP-TART was 20 cases for the experienced robotic surgeon. SP-TART is technically feasible and safe with a short incision length and short operation time. It is a valuable alternative operative option with good surgical outcomes and outstanding cosmetic results.
Collapse
|
9
|
Affiliation(s)
- A Arezzo
- Department of Surgical Sciences, University of Turin, c.so Dogliotti 14, 10126, Turin, Italy.
| | - G Gagliardi
- Department of Surgery, University of Illinois College of Medicine at Chicago, Chicago, IL, USA
| |
Collapse
|
10
|
First Clinical Experience With Single-Port Robotic Transanal Minimally Invasive Surgery: Phase II Trial of the Initial 26 Cases. Dis Colon Rectum 2021; 64:1003-1013. [PMID: 34001709 DOI: 10.1097/dcr.0000000000001999] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Many transanal platforms have been developed to address the challenge of reach and vision when operating transanally. The single-port robot was specifically designed for narrow-aperture surgery and is a promising platform for minimally invasive transanal surgery. OBJECTIVE The purpose of this phase II trial is to evaluate the safety and feasibility of the initial clinical experience with single-port robot transanal minimally invasive surgery. DESIGN In a prospective phase II trial, patients with rectal neoplasms eligible for local excision were enrolled for single-port robotic transanal minimally invasive surgery. SETTING The study was conducted between October 2018 and March 2020 at a tertiary referral hospital. PATIENTS/INTERVENTION Twenty-six consecutive patients underwent single-port robotic transanal minimally invasive surgery resection of rectal lesions. MAIN OUTCOME MEASURES The primary end point of the study was the efficacy and safety of single-port robotic transanal minimally invasive surgery. RESULTS There were 13 men and 13 women, with an average lesion size of 2.9 cm (range, 1.0-6.0 cm) and average level of 4.8 cm from the anorectal ring (range, 0-30 cm). Ten patients had a preoperative diagnosis of adenocarcinoma, 7 of whom received neoadjuvant chemoradiation (range, 4500-5580 cGy with concurrent oral capecitabine). Eighty-eight percent of cases were completed by single-port robotic transanal minimally invasive surgery; 2 were converted to transanal endoscopic microsurgery, and 1 patient underwent a low anterior resection. There were no piecemeal extractions, and all margins were negative on final pathology. There were no mortalities, and the morbidity rate was 15.4%. There have been no local recurrences, with a mean follow-up of 5.8 months (range, 0-15.9 months). LIMITATIONS The study was limited by small sample size, short-term follow up, and a single-surgeon experience. CONCLUSION Single-port robotic transanal minimally invasive surgery procedures are safe and feasible in patients with select benign and malignant rectal lesions. Future trials will need to evaluate the long-term safety and efficacy of single-port robotic transanal minimally invasive surgery. See Video Abstract at http://links.lww.com/DCR/B605. PRIMERA EXPERIENCIA CLNICA CON CIRUGA MNIMAMENTE INVASIVA TRANSANAL ROBTICA DE PUERTO NICO ENSAYO DE FASE II DE LOS CASOS INICIALES ANTECEDENTES:Se han desarrollado muchas plataformas transanales para abordar el desafío del alcance y la visión cuando se opera de manera transanal. El robot de un solo puerto fue diseñado específicamente para la cirugía de apertura estrecha y es una plataforma prometedora para la cirugía transanal mínimamente invasiva.OBJETIVO:El propósito de este ensayo de fase II es evaluar la seguridad y viabilidad de la experiencia clínica inicial con la cirugía mínimamente invasiva transanal con robot de puerto único.DISEÑO:En un ensayo prospectivo de fase II, los pacientes con neoplasias rectales elegibles para la escisión local se inscribieron para la cirugía mínimamente invasiva transanal robótica de puerto único.AJUSTE:El estudio se realizó entre octubre de 2018 y marzo de 2020 en un hospital de referencia terciario.PACIENTES / INTERVENCIÓN:Veintiséis pacientes consecutivos fueron sometidos a cirugía mínimamente invasiva transanal robótica de puerto único para resección de lesiones rectales.PRINCIPALES MEDIDAS DE RESULTADO:El criterio de valoración principal del estudio fue la eficacia y seguridad de la cirugía mínimamente invasiva transanal robótica de puerto único.RESULTADOS:Hubo 13 hombres y 13 mujeres, con un tamaño de lesión promedio de 2.9 cm (rango 1.0-6.0 cm) y un nivel promedio de 4.8 cm del anillo anorrectal (rango 0-30 cm). Diez pacientes tenían un diagnóstico preoperatorio de adenocarcinoma, 7 de los cuales recibieron quimiorradiación neoadyuvante (rango 4500-5580 cGy con capecitabina oral concurrente). El 88% de los casos se completaron mediante cirugía mínimamente invasiva transanal robótica de puerto único; 2 se convirtieron a microcirugía endoscópica transanal y 1 se sometió a una resección anterior baja. No hubo extracciones parciales y todos los márgenes fueron negativos en la patología final. No hubo mortalidad y una tasa de morbilidad del 15,4%. No ha habido recidivas locales, con un seguimiento medio de 5,8 meses (rango 0-15,9 meses).LIMITACIONES:El estudio estuvo limitado por un tamaño de muestra pequeño, un seguimiento a corto plazo y la experiencia de un solo cirujano.CONCLUSIÓN:Los procedimientos de cirugía mínimamente invasiva transanal robótica de puerto único son seguros y factibles en pacientes con lesiones rectales benignas y malignas seleccionadas. Los ensayos futuros deberán evaluar la seguridad y eficacia a largo plazo de la cirugía mínimamente invasiva transanal robótica de puerto único. Consulte Video Resumen en http://links.lww.com/DCR/B605. (Traducción-Dr. Eduardo Londoño-Schimmer).
Collapse
|
11
|
Envisioning the future of colorectal surgery: preclinical assessment and detailed description of an endoluminal robotic system (ColubrisMX ELS). Tech Coloproctol 2021; 25:1199-1207. [PMID: 34224035 DOI: 10.1007/s10151-021-02481-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/08/2021] [Accepted: 06/12/2021] [Indexed: 01/11/2023]
Abstract
BACKGROUND The EndoLuminal Surgical System (ELS) is an emerging non-linear robotic system specifically designed for transanal surgery that allows for excision of colorectal neoplasia and luminal defect closure. METHODS An evaluation of ELS was conducted by a single surgeon in a preclinical setting at the EndoSurgical Center of Florida in Orlando, between October 1st, 2020 and December 31st, 2020, using porcine colon as a model. Mock lesions measured 2.5 to 3.5 cm were excised partial-thickness. Specimen quality and excision time was assessed and evaluated. RESULTS Twenty consecutive robotic transanal minimally invasive surgery (TAMIS) operations utilizing the ELS system were successfully performed without fragmentation. The mean and standard deviation procedure time for all 20 cases was 18.41 ± 14.15 min. The latter 10 cases were completed in substantially less time, suggesting that ELS requires at least 10 preclinical cases for a surgeon to become familiar with the technology. A second task, namely suture closure of the partial-thickness defect, was performed in 9 of the 20 cases. Mean time and standard deviation for this task measured 27.89 ± 10.07 min. There were no adverse events. CONCLUSIONS ELS was successful in performing the tasks of partial-thickness disc excision and closure in a preclinical evaluation. Further study is necessary to determine its clinical applicability.
Collapse
|