1
|
Yu Y, Song G, Dai M, Li P, Xu J, Yin Y, Wang J. Tailoring silk-based covering material with matched mechanical properties for vascular tissue engineering. Sci Rep 2024; 14:23347. [PMID: 39375456 PMCID: PMC11458864 DOI: 10.1038/s41598-024-75343-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Accepted: 10/04/2024] [Indexed: 10/09/2024] Open
Abstract
Vascular covered stents play a significant therapeutic role in cardiovascular diseases. However, the poor compliance and biological inertness of commercial materials cause post-implantation complications. Silk fibroin (SF), as a biomaterial, possesses satisfactory hemocompatibility and tissue compatibility. In this study, we developed a silk film for use in covered stents by employing a layer-by-layer self-assembly strategy with regenerated SF on silk braiding fabric. We investigated the effects on the mechanical properties of the silk films in detail, which were closely correlated with fabric parameters and layer-by-layer self-assembly. The results showed that there was a significant relationship between these factors and both the compliance and mechanical strength. The 1 × 2/90°/100/SF6 film exhibited excellent mechanical properties. Notably, compliance reached 2.6%/100 mmHg, matching that of the human saphenous vein. Thus, this strategy shows promise in developing a novel covered stent, with biocompatible and comprehensive mechanical properties, and significant potential for clinical applications.
Collapse
Affiliation(s)
- Yangxiao Yu
- College of Textile and Clothing Engineering, Soochow University, Suzhou, 215123, Jiangsu, China
| | - Guangzhou Song
- College of Textile and Clothing Engineering, Soochow University, Suzhou, 215123, Jiangsu, China
| | - Mengnan Dai
- College of Textile and Clothing Engineering, Soochow University, Suzhou, 215123, Jiangsu, China
| | - Peixuan Li
- College of Textile and Clothing Engineering, Soochow University, Suzhou, 215123, Jiangsu, China
| | - Jianmei Xu
- College of Textile and Clothing Engineering, Soochow University, Suzhou, 215123, Jiangsu, China
- National Engineering Laboratory for Modern Silk, Soochow University, Suzhou, 215123, Jiangsu, China
| | - Yin Yin
- Department of Medicine, Soochow University, Suzhou, 215123, Jiangsu, China
| | - Jiannan Wang
- College of Textile and Clothing Engineering, Soochow University, Suzhou, 215123, Jiangsu, China.
- National Engineering Laboratory for Modern Silk, Soochow University, Suzhou, 215123, Jiangsu, China.
- , No. 199 Ren-ai Road, Suzhou Industrial Park, Suzhou, 215123, Jiangsu, China.
| |
Collapse
|
2
|
Ramella A, Lissoni V, Bridio S, Rodriguez Matas JF, Trimarchi S, Grossi B, Stefanini GG, Migliavacca F, Luraghi G. On the necessity to include arterial pre-stress in patient-specific simulations of minimally invasive procedures. Biomech Model Mechanobiol 2024; 23:525-537. [PMID: 38063955 PMCID: PMC10963513 DOI: 10.1007/s10237-023-01789-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Accepted: 10/27/2023] [Indexed: 03/26/2024]
Abstract
Transcatheter aortic valve implantation (TAVI) and thoracic endovascular aortic repair (TEVAR) are minimally invasive procedures for treating aortic valves and diseases. Finite element simulations have proven to be valuable tools in predicting device-related complications. In the literature, the inclusion of aortic pre-stress has not been widely investigated. It plays a crucial role in determining the biomechanical response of the vessel and the device-tissue interaction. This study aims at demonstrating how and when to include the aortic pre-stress in patient-specific TAVI and TEVAR simulations. A percutaneous aortic valve and a stent-graft were implanted in aortic models reconstructed from patient-specific CT scans. Two scenarios for each patient were compared, i.e., including and neglecting the wall pre-stress. The neglection of pre-stress underestimates the contact pressure of 48% and 55%, the aorta stresses of 162% and 157%, the aorta strains of 77% and 21% for TAVI and TEVAR models, respectively. The stent stresses are higher than 48% with the pre-stressed aorta in TAVI simulations; while, similar results are obtained in TEVAR cases. The distance between the device and the aorta is similar with and without pre-stress. The inclusion of the aortic wall pre-stress has the capability to give a better representation of the biomechanical behavior of the arterial tissues and the implanted device. It is suggested to include this effect in patient-specific simulations replicating the procedures.
Collapse
Affiliation(s)
- Anna Ramella
- Computational Biomechanics Laboratory - LaBS, Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Piazza L. da Vinci 32, 20133, Milan, Italy
| | - Vittorio Lissoni
- Computational Biomechanics Laboratory - LaBS, Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Piazza L. da Vinci 32, 20133, Milan, Italy
| | - Sara Bridio
- Computational Biomechanics Laboratory - LaBS, Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Piazza L. da Vinci 32, 20133, Milan, Italy
| | - Jose Felix Rodriguez Matas
- Computational Biomechanics Laboratory - LaBS, Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Piazza L. da Vinci 32, 20133, Milan, Italy
| | - Santi Trimarchi
- Section of Vascular Surgery, Cardio Thoracic Vascular Department, Foundation IRCCS Ca' Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 35, Milan, Italy
- Department of Clinical Sciences and Community Health, University of Milan, Via Della Commenda 19, 20122, Milan, Italy
| | - Benedetta Grossi
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
| | - Giulio G Stefanini
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
- IRCCS Humanitas Research Hospital, Via Alessandro Manzoni 56, 20089, Rozzano, Milan, Italy
| | - Francesco Migliavacca
- Computational Biomechanics Laboratory - LaBS, Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Piazza L. da Vinci 32, 20133, Milan, Italy
| | - Giulia Luraghi
- Computational Biomechanics Laboratory - LaBS, Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Piazza L. da Vinci 32, 20133, Milan, Italy.
| |
Collapse
|
3
|
Bernini M, Hellmuth R, Dunlop C, Ronan W, Vaughan TJ. Recommendations for finite element modelling of nickel-titanium stents-Verification and validation activities. PLoS One 2023; 18:e0283492. [PMID: 37556457 PMCID: PMC10411813 DOI: 10.1371/journal.pone.0283492] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Accepted: 03/11/2023] [Indexed: 08/11/2023] Open
Abstract
The objective of this study is to present a credibility assessment of finite element modelling of self-expanding nickel-titanium (Ni-Ti) stents through verification and validation (VV) activities, as set out in the ASME VV-40 standard. As part of the study, the role of calculation verification, model input sensitivity, and model validation is examined across three different application contexts (radial compression, stent deployment in a vessel, fatigue estimation). A commercially available self-expanding Ni-Ti stent was modelled, and calculation verification activities addressed the effects of mesh density, element integration and stable time increment on different quantities of interests, for each context of use considered. Sensitivity analysis of the geometrical and material input parameters and validation of deployment configuration with in vitro comparators were investigated. Results showed similar trends for global and local outputs across the contexts of use in response to the selection of discretization parameters, although with varying sensitivities. Mesh discretisation showed substantial variability for less than 4 × 4 element density across the strut cross-section in radial compression and deployment cases, while a finer grid was deemed necessary in fatigue estimation for reliable predictions of strain/stress. Element formulation also led to substantial variation depending on the chosen integration options. Furthermore, for explicit analyses, model results were highly sensitive to the chosen target time increment (e.g., mass scaling parameters), irrespective of whether quasistatic conditions were ensured (ratios of kinetic and internal energies below 5%). The higher variability was found for fatigue life simulation, with the estimation of fatigue safety factor varying up to an order of magnitude depending on the selection of discretization parameters. Model input sensitivity analysis highlighted that the predictions of outputs such as radial force and stresses showed relatively low sensitivity to Ni-Ti material parameters, which suggests that the calibration approaches used in the literature to date appear reasonable, but a higher sensitivity to stent geometry, namely strut thickness and width, was found. In contrast, the prediction of vessel diameter following deployment was least sensitive to numerical parameters, and its validation with in vitro comparators offered a simple and accurate (error ~ 1-2%) method when predicting diameter gain, and lumen area, provided that the material of the vessel is appropriately characterized and modelled.
Collapse
Affiliation(s)
- Martina Bernini
- Biomechanics Research Centre (BioMEC), College of Science and Engineering, University of Galway, Galway, Ireland
- Vascular Flow Technologies, Dundee, United Kingdom
| | | | - Craig Dunlop
- Vascular Flow Technologies, Dundee, United Kingdom
| | - William Ronan
- Biomechanics Research Centre (BioMEC), College of Science and Engineering, University of Galway, Galway, Ireland
| | - Ted J. Vaughan
- Biomechanics Research Centre (BioMEC), College of Science and Engineering, University of Galway, Galway, Ireland
| |
Collapse
|
4
|
Agrafiotis E, Mayer C, Grabenwöger M, Zimpfer D, Regitnig P, Mächler H, Holzapfel GA. Global and local stiffening of ex vivo-perfused stented human thoracic aortas: A mock circulation study. Acta Biomater 2023; 161:170-183. [PMID: 36849029 DOI: 10.1016/j.actbio.2023.02.028] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 01/25/2023] [Accepted: 02/20/2023] [Indexed: 02/27/2023]
Abstract
The effects of thoracic endovascular repair (TEVAR) on the biomechanical properties of aortic tissue have not been adequately studied. Understanding these features is important for the management of endograft-triggered complications of a biomechanical nature. This study aims to examine how stent-graft implantation affects the elastomechanical behavior of the aorta. Non-pathological human thoracic aortas (n=10) were subjected to long-standing perfusion (8h) within a mock circulation loop under physiological conditions. To quantify compliance and its mismatch in the test periods without and with a stent, the aortic pressure and the proximal cyclic circumferential displacement were measured. After perfusion, biaxial tension tests (stress-stretch) were carried out to examine the stiffness profiles between non-stented and stented tissue, followed by a histological assessment. Experimental evidence shows: (i) a significant reduction in aortic distensibility after TEVAR, indicating aortic stiffening and compliance mismatch, (ii) a stiffer behavior of the stented samples compared to the non-stented samples with an earlier entry into the nonlinear part of the stress-stretch curve and (iii) strut-induced histological remodeling of the aortic wall. The biomechanical and histological comparison of the non-stented and stented aortas provides new insights into the interaction between the stent-graft and the aortic wall. The knowledge gained could refine the stent-graft design to minimize the stent-induced impacts on the aortic wall and the resulting complications. STATEMENT OF SIGNIFICANCE: Stent-related cardiovascular complications occur the moment the stent-graft expands on the human aortic wall. Clinicians base their diagnosis on the anatomical morphology of CT scans while neglecting the endograft-triggered biomechanical events that compromise aortic compliance and wall mechanotransduction. Experimental replication of endovascular repair in cadaver aortas within a mock circulation loop may have a catalytic effect on biomechanical and histological findings without an ethical barrier. Demonstrating interactions between the stent and the wall can help clinicians make a broader diagnosis such as ECG-triggered oversizing and stent-graft characteristics based on patient-specific anatomical location and age. In addition, the results can be used to optimize towards more aortophilic stent grafts.
Collapse
Affiliation(s)
| | - Christian Mayer
- Department of Cardiac Surgery, Medical University of Graz, Austria
| | - Martin Grabenwöger
- Department of Cardiovascular Surgery, Clinic Floridsdorf, Vienna, Austria
| | - Daniel Zimpfer
- Department of Cardiac Surgery, Medical University of Graz, Austria
| | - Peter Regitnig
- Institute of Pathology, Medical University of Graz, Austria
| | - Heinrich Mächler
- Department of Cardiac Surgery, Medical University of Graz, Austria
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Graz, Austria; Department of Structural Engineering, Norwegian University of Science and Technology (NTNU), Trondheim, Norway.
| |
Collapse
|
5
|
Vallejo-Zamora JA, Vega-Cantu YI, Rodriguez C, Cordell GA, Rodriguez-Garcia A. Drug-Eluting, Bioresorbable Cardiovascular Stents─Challenges and Perspectives. ACS APPLIED BIO MATERIALS 2022; 5:4701-4717. [PMID: 36150217 DOI: 10.1021/acsabm.2c00551] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Globally, the leading causes of natural death are attributed to coronary heart disease and type 1 and type 2 diabetes. High blood pressure levels, high cholesterol levels, smoking, and poor eating habits lead to the agglomeration of plaque in the arteries, reducing the blood flow. The implantation of devices used to unclog vessels, known as stents, sometimes results in a lack of irrigation due to the excessive proliferation of endothelial tissue within the blood vessels and is known as restenosis. The use of drug-eluting stents (DESs) to deliver antiproliferative drugs has led to the development of different encapsulation techniques. However, due to the potency of the drugs used in the initial stent designs, a chronic inflammatory reaction of the arterial wall known as thrombosis can cause a myocardial infarction (MI). One of the most promising drugs to reduce this risk is everolimus, which can be encapsulated in lipid systems for controlled release directly into the artery. This review aims to discuss the current status of stent design, fabrication, and functionalization. Variables such as the mechanical properties, metals and their alloys, drug encapsulation and controlled elution, and stent degradation are also addressed. Additionally, this review covers the use of polymeric surface coatings on stents and the recent advances in layer-by-layer coating and drug delivery. The advances in nanoencapsulation techniques such as liposomes and micro- and nanoemulsions and their functionalization in bioresorbable, drug-eluting stents are also highlighted.
Collapse
Affiliation(s)
- Julio A Vallejo-Zamora
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey, Nuevo León64849, Mexico
| | - Yadira I Vega-Cantu
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey, Nuevo León64849, Mexico
| | - Ciro Rodriguez
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey, Nuevo León64849, Mexico
- Laboratorio Nacional de Manufactura Aditiva y Digital (MADIT), Apodaca, Nuevo León66629, Mexico
| | - Geoffrey A Cordell
- Natural Products, Inc., Evanston, Illinois60201, United States
- College of Pharmacy, University of Florida, Gainesville, Florida32610, United States
| | - Aida Rodriguez-Garcia
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey, Nuevo León64849, Mexico
- Universidad Autónoma de Nuevo León, Facultad de Ciencias Biológicas, Instituto de Biotecnología, Ciudad Universitaria, Ave. Pedro de Alba S/N, San Nicolás de los Garza, Nuevo León66455, Mexico
| |
Collapse
|
6
|
Hynes N, Acharya Y, Sultan S. The contemporary design of endovascular aneurysm stent-graft materials: PTFE versus polyester. Front Surg 2022; 9:984727. [PMID: 36051707 PMCID: PMC9424654 DOI: 10.3389/fsurg.2022.984727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2022] [Accepted: 08/02/2022] [Indexed: 11/13/2022] Open
Abstract
Endovascular aneurysm repair of the abdominal aorta (EVAR) and of the thoracic aorta (TEVAR) have revolutionised therapeutic strategies in the management of aortic pathology, and endovascular repair is now an established and attractive alternative to open surgical repair (OSR) due to its superior short-term safety profile. However, opinions are divided regarding its long-term cost-effectiveness, which is reflected in the controversial NICE guidelines on abdominal aortic aneurysm (AAA) repair published in 2018, which advised against EVAR for elective aortic repair due to high secondary intervention rates and resultant associated costs. There is no doubt that OSR continues to have a valuable role to play in aortic repair, but it is not universally applicable, especially in older and sicker patients. Therefore, we should not dismiss EVAR and TEVAR without examining the reasons for long-term failure, and the most obvious starting point is stent graft material properties. Polytetrafluoroethylene (PTFE) and polyester are the two most common stent-graft materials; however, there has been no objective comparison of PTFE and polyester stent-graft post-procedural outcomes in EVAR and TEVAR, or even OSR. This lack of definitive data on different stent-graft materials and their configuration necessitates a comprehensive review to elucidate the post-procedural outcome in terms of endograft failure, cardiovascular events, and aortic-related mortality and morbidity.
Collapse
Affiliation(s)
- Niamh Hynes
- CURAM SFI Centre for Medical Devices, Biomedical Sciences, National University of Ireland Galway, Galway, Ireland
- Department of Vascular & Endovascular Surgery, Western Vascular Institute, Galway University Hospital, Galway, Ireland
| | - Yogesh Acharya
- Department of Vascular & Endovascular Surgery, Western Vascular Institute, Galway University Hospital, Galway, Ireland
| | - Sherif Sultan
- Department of Vascular & Endovascular Surgery, Western Vascular Institute, Galway University Hospital, Galway, Ireland
- Department of Vascular & Endovascular Surgery, Galway Clinic, Galway, Ireland
| |
Collapse
|
7
|
Sultan S, Concannon J, Veerasingam D, Tawfick W, McHugh P, Jordan F, Hynes N. Endovascular versus conventional open surgical repair for thoracoabdominal aortic aneurysms. Cochrane Database Syst Rev 2022; 4:CD012926. [PMID: 35363887 PMCID: PMC9370075 DOI: 10.1002/14651858.cd012926.pub2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Thoracoabdominal aortic aneurysms (TAAAs) are a life-threatening condition which remain difficult to treat. Endovascular and open surgical repair (OSR) provide treatment options for patients, however, due to the lack of clinical trials comparing these, the optimum treatment option is unknown. OBJECTIVES To assess the effectiveness and safety of endovascular repair versus conventional OSR for the treatment of TAAAs. SEARCH METHODS The Cochrane Vascular Information Specialist searched the Cochrane Vascular Specialised Register, CENTRAL, MEDLINE, Embase, CINAHL and AMED databases and World Health Organization International Clinical Trials Registry Platform and ClinicalTrials.gov trials registers to 26 April 2021. We also searched references of relevant articles retrieved from the electronic search for additional citations. SELECTION CRITERIA We considered all published and unpublished randomised controlled trials (RCTs) and controlled clinical trials (CCTs) comparing endovascular repair to OSR for TAAAs for inclusion in the review. The main outcomes of interest were prevention of aneurysm rupture (participants without aneurysm rupture up to 5 years from intervention), aneurysm-related mortality (30 days and 12 months), all-cause mortality, spinal cord ischaemia (paraplegia, paraparesis), visceral arterial branch compromise causing mesenteric ischaemia or renal failure, and rate of reintervention. DATA COLLECTION AND ANALYSIS Two review authors independently screened all titles and abstracts identified from the searches to identify those that met the inclusion criteria. We planned to undertake data collection, risk of bias assessment, and analysis in accordance with Cochrane recommendations. We planned to assess the certainty of the evidence using GRADE. MAIN RESULTS No RCTs or CCTs met the inclusion criteria for this review. AUTHORS' CONCLUSIONS Due to the lack of RCTs or CCTs, we were unable to determine the safety and effectiveness of endovascular compared to OSR in patients with TAAAs and are unable to provide any evidence on the optimal surgical intervention for this cohort of patients. High-quality RCTs or CCTs addressing this objective are necessary, however conducting such studies will be logistically and ethically challenging for this life-threatening disease.
Collapse
Affiliation(s)
- Sherif Sultan
- Vascular Surgery, Galway University Hospital, Galway, Ireland
| | - Jamie Concannon
- Biomedical Engineering, Vascular and Endovascular Surgery, National University of Ireland Galway, Galway, Ireland
| | - Dave Veerasingam
- Cardiothoracic Surgery, Galway University Hospital, Galway, Ireland
| | - Wael Tawfick
- Department of Vascular and Endovascular Surgery, Western Vascular Institute, University College Hospital, Galway, Ireland
| | - Peter McHugh
- Mechanical and Biomedical Engineering, National University of Ireland Galway, Galway, Ireland
| | - Fionnuala Jordan
- School of Nursing and Midwifery, National University of Ireland Galway, Galway, Ireland
| | - Niamh Hynes
- CURAM, SFI Research Centre for Medical Devices, National University of Ireland Galway, Galway, Ireland
| |
Collapse
|
8
|
Ramella A, Migliavacca F, Rodriguez Matas JF, Heim F, Dedola F, Marconi S, Conti M, Allievi S, Mandigers TJ, Bissacco D, Domanin M, Trimarchi S, Luraghi G. Validation and Verification of High-Fidelity Simulations of Thoracic Stent-Graft Implantation. Ann Biomed Eng 2022; 50:1941-1953. [PMID: 35854187 PMCID: PMC9794542 DOI: 10.1007/s10439-022-03014-y] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Accepted: 07/08/2022] [Indexed: 12/31/2022]
Abstract
Thoracic Endovascular Aortic Repair (TEVAR) is the preferred treatment option for thoracic aortic pathologies and consists of inserting a self-expandable stent-graft into the pathological region to restore the lumen. Computational models play a significant role in procedural planning and must be reliable. For this reason, in this work, high-fidelity Finite Element (FE) simulations are developed to model thoracic stent-grafts. Experimental crimp/release tests are performed to calibrate stent-grafts material parameters. Stent pre-stress is included in the stent-graft model. A new methodology for replicating device insertion and deployment with explicit FE simulations is proposed. To validate this simulation, the stent-graft is experimentally released into a 3D rigid aortic phantom with physiological anatomy and inspected in a computed tomography (CT) scan at different time points during deployment with an ad-hoc set-up. A verification analysis of the adopted modeling features compared to the literature is performed. With the proposed methodology the error with respect to the CT is on average 0.92 ± 0.64%, while it is higher when literature models are adopted (on average 4.77 ± 1.83%). The presented FE tool is versatile and customizable for different commercial devices and applicable to patient-specific analyses.
Collapse
Affiliation(s)
- Anna Ramella
- grid.4643.50000 0004 1937 0327Computational Biomechanics Laboratory – LaBS, Department of Chemistry, Materials and Chemical Engineering ‘Giulio Natta’, Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy
| | - Francesco Migliavacca
- grid.4643.50000 0004 1937 0327Computational Biomechanics Laboratory – LaBS, Department of Chemistry, Materials and Chemical Engineering ‘Giulio Natta’, Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy
| | - Jose Felix Rodriguez Matas
- grid.4643.50000 0004 1937 0327Computational Biomechanics Laboratory – LaBS, Department of Chemistry, Materials and Chemical Engineering ‘Giulio Natta’, Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy
| | - Frederic Heim
- grid.9156.b0000 0004 0473 5039Laboratoire de Physique et Mécanique des Textiles, Université de Haute-Alsace, 11 rue Alfred Werner, 68093 Mulhouse, France
| | - Francesca Dedola
- grid.4708.b0000 0004 1757 2822Clinical and Community Sciences Department, Università degli Studi di Milano, Via della Commenda 19, 20122 Milan, Italy
| | - Stefania Marconi
- grid.8982.b0000 0004 1762 5736Department of Civil Engineering and Architecture (DICAr), University of Pavia, Via Ferrata 3, 27100 Pavia, Italy
| | - Michele Conti
- grid.8982.b0000 0004 1762 5736Department of Civil Engineering and Architecture (DICAr), University of Pavia, Via Ferrata 3, 27100 Pavia, Italy
| | - Sara Allievi
- grid.4708.b0000 0004 1757 2822Clinical and Community Sciences Department, Università degli Studi di Milano, Via della Commenda 19, 20122 Milan, Italy
| | - Tim J. Mandigers
- grid.414818.00000 0004 1757 8749Unit of Vascular Surgery, I.R.C.C.S. Fondazione Cà Granda Policlinico Milano, Via Francesco Sforza 35, Milan, Italy
| | - Daniele Bissacco
- grid.414818.00000 0004 1757 8749Unit of Vascular Surgery, I.R.C.C.S. Fondazione Cà Granda Policlinico Milano, Via Francesco Sforza 35, Milan, Italy
| | - Maurizio Domanin
- grid.4708.b0000 0004 1757 2822Clinical and Community Sciences Department, Università degli Studi di Milano, Via della Commenda 19, 20122 Milan, Italy ,grid.414818.00000 0004 1757 8749Unit of Vascular Surgery, I.R.C.C.S. Fondazione Cà Granda Policlinico Milano, Via Francesco Sforza 35, Milan, Italy
| | - Santi Trimarchi
- grid.4708.b0000 0004 1757 2822Clinical and Community Sciences Department, Università degli Studi di Milano, Via della Commenda 19, 20122 Milan, Italy ,grid.414818.00000 0004 1757 8749Unit of Vascular Surgery, I.R.C.C.S. Fondazione Cà Granda Policlinico Milano, Via Francesco Sforza 35, Milan, Italy
| | - Giulia Luraghi
- grid.4643.50000 0004 1937 0327Computational Biomechanics Laboratory – LaBS, Department of Chemistry, Materials and Chemical Engineering ‘Giulio Natta’, Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy
| |
Collapse
|