1
|
Saniour I, Aydé R, Perrier AL, Gaborit G, Duvillaret L, Sablong R, Beuf O. Active optical-based detuning circuit for receiver endoluminal coil. Biomed Phys Eng Express 2017. [DOI: 10.1088/2057-1976/aa5db0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
2
|
Dorez H, Sablong R, Canaple L, Saint-Jalmes H, Gaillard S, Moussata D, Beuf O. Endoluminal high-resolution MR imaging protocol for colon walls analysis in a mouse model of colitis. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2016; 29:657-69. [PMID: 26965510 DOI: 10.1007/s10334-016-0539-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2015] [Revised: 02/03/2016] [Accepted: 02/18/2016] [Indexed: 12/13/2022]
Abstract
OBJECTIVE An endoluminal magnetic resonance (MR) imaging protocol including the design of an endoluminal coil (EC) was defined for high-spatial-resolution MR imaging of mice gastrointestinal walls at 4.7 T. MATERIALS AND METHODS A receive-only radiofrequency single-loop coil was developed for mice colon wall imaging. Combined with a specific protocol, the prototype was first characterized in vitro on phantoms and on vegetables. Signal-to-noise ratio (SNR) profiles were compared with a quadrature volume birdcage coil (QVBC). Endoluminal MR imaging protocol combined with the EC was assessed in vivo on mice. RESULTS The SNR measured close to the coil is significantly higher (10 times and up to 3 mm of the EC center) than the SNR measured with the QVBC. The gain in SNR can be used to reduce the in-plane pixel size up to 39 × 39 µm(2) (234 µm slice thickness) without time penalty. The different colon wall layers can only be distinguished on images acquired with the EC. CONCLUSION Dedicated EC provides suitable images for the assessment of mice colon wall layers. This proof of concept provides gains in spatial resolution and leads to adequate protocols for the assessment of human colorectal cancer, and can now be used as a new imaging tool for a better understanding of the pathology.
Collapse
Affiliation(s)
- Hugo Dorez
- Université de Lyon, CREATIS, CNRS UMR 5220, INSERM U1044, INSA-Lyon, Université Lyon 1, Villeurbanne, France.
| | - Raphaël Sablong
- Université de Lyon, CREATIS, CNRS UMR 5220, INSERM U1044, INSA-Lyon, Université Lyon 1, Villeurbanne, France
| | - Laurence Canaple
- Institut de Génomique Fonctionnelle de Lyon, Université de Lyon 1, UMR 5242 CNRS, Ecole Normale Supérieure de Lyon, Lyon, France
| | - Hervé Saint-Jalmes
- LTSI, INSERM U642, Université Rennes 1, Rennes, France.,CRLCC, Centre Eugène Marquis, Rennes, France
| | - Sophie Gaillard
- Université de Lyon, CREATIS, CNRS UMR 5220, INSERM U1044, INSA-Lyon, Université Lyon 1, Villeurbanne, France
| | - Driffa Moussata
- Université de Lyon, CREATIS, CNRS UMR 5220, INSERM U1044, INSA-Lyon, Université Lyon 1, Villeurbanne, France.,Hôpital Régional Universitaire de Tours-Service Hépato-Gastroentérologie, Tours, France
| | - Olivier Beuf
- Université de Lyon, CREATIS, CNRS UMR 5220, INSERM U1044, INSA-Lyon, Université Lyon 1, Villeurbanne, France
| |
Collapse
|
3
|
Detti V, Grenier D, Perrin E, Beuf O. Assessment of radiofrequency self-heating around a metallic wire with MR T1-based thermometry. Magn Reson Med 2011; 66:448-55. [PMID: 21360744 DOI: 10.1002/mrm.22834] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2009] [Revised: 12/17/2010] [Accepted: 12/20/2010] [Indexed: 11/10/2022]
Affiliation(s)
- V Detti
- Université de Lyon, CREATIS, UMR CNRS 5220, Inserm U 1044, Insa-Lyon, Villeurbanne, France.
| | | | | | | |
Collapse
|