1
|
Tsarouchi MI, Hoxhaj A, Mann RM. New Approaches and Recommendations for Risk-Adapted Breast Cancer Screening. J Magn Reson Imaging 2023; 58:987-1010. [PMID: 37040474 DOI: 10.1002/jmri.28731] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 03/23/2023] [Accepted: 03/24/2023] [Indexed: 04/13/2023] Open
Abstract
Population-based breast cancer screening using mammography as the gold standard imaging modality has been in clinical practice for over 40 years. However, the limitations of mammography in terms of sensitivity and high false-positive rates, particularly in high-risk women, challenge the indiscriminate nature of population-based screening. Additionally, in light of expanding research on new breast cancer risk factors, there is a growing consensus that breast cancer screening should move toward a risk-adapted approach. Recent advancements in breast imaging technology, including contrast material-enhanced mammography (CEM), ultrasound (US) (automated-breast US, Doppler, elastography US), and especially magnetic resonance imaging (MRI) (abbreviated, ultrafast, and contrast-agent free), may provide new opportunities for risk-adapted personalized screening strategies. Moreover, the integration of artificial intelligence and radiomics techniques has the potential to enhance the performance of risk-adapted screening. This review article summarizes the current evidence and challenges in breast cancer screening and highlights potential future perspectives for various imaging techniques in a risk-adapted breast cancer screening approach. EVIDENCE LEVEL: 1. TECHNICAL EFFICACY: Stage 5.
Collapse
Affiliation(s)
- Marialena I Tsarouchi
- Department of Radiology, Nuclear Medicine and Anatomy, Radboud University Medical Center, Nijmegen, the Netherlands
- Department of Radiology, the Netherlands Cancer Institute, Amsterdam, the Netherlands
| | - Alma Hoxhaj
- Department of Radiology, Nuclear Medicine and Anatomy, Radboud University Medical Center, Nijmegen, the Netherlands
- Department of Radiology, the Netherlands Cancer Institute, Amsterdam, the Netherlands
| | - Ritse M Mann
- Department of Radiology, Nuclear Medicine and Anatomy, Radboud University Medical Center, Nijmegen, the Netherlands
- Department of Radiology, the Netherlands Cancer Institute, Amsterdam, the Netherlands
| |
Collapse
|
2
|
Mendez AM, Fang LK, Meriwether CH, Batasin SJ, Loubrie S, Rodríguez-Soto AE, Rakow-Penner RA. Diffusion Breast MRI: Current Standard and Emerging Techniques. Front Oncol 2022; 12:844790. [PMID: 35880168 PMCID: PMC9307963 DOI: 10.3389/fonc.2022.844790] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Accepted: 05/11/2022] [Indexed: 11/13/2022] Open
Abstract
The role of diffusion weighted imaging (DWI) as a biomarker has been the subject of active investigation in the field of breast radiology. By quantifying the random motion of water within a voxel of tissue, DWI provides indirect metrics that reveal cellularity and architectural features. Studies show that data obtained from DWI may provide information related to the characterization, prognosis, and treatment response of breast cancer. The incorporation of DWI in breast imaging demonstrates its potential to serve as a non-invasive tool to help guide diagnosis and treatment. In this review, current technical literature of diffusion-weighted breast imaging will be discussed, in addition to clinical applications, advanced techniques, and emerging use in the field of radiomics.
Collapse
Affiliation(s)
- Ashley M. Mendez
- Department of Radiology, University of California San Diego, La Jolla, CA, United States
| | - Lauren K. Fang
- Department of Radiology, University of California San Diego, La Jolla, CA, United States
| | - Claire H. Meriwether
- Department of Radiology, University of California San Diego, La Jolla, CA, United States
| | - Summer J. Batasin
- Department of Radiology, University of California San Diego, La Jolla, CA, United States
| | - Stéphane Loubrie
- Department of Radiology, University of California San Diego, La Jolla, CA, United States
| | - Ana E. Rodríguez-Soto
- Department of Radiology, University of California San Diego, La Jolla, CA, United States
| | - Rebecca A. Rakow-Penner
- Department of Radiology, University of California San Diego, La Jolla, CA, United States,Department of Bioengineering, University of California San Diego, La Jolla, CA, United States,*Correspondence: Rebecca A. Rakow-Penner,
| |
Collapse
|
3
|
Iima M, Honda M, Sigmund EE, Ohno Kishimoto A, Kataoka M, Togashi K. Diffusion MRI of the breast: Current status and future directions. J Magn Reson Imaging 2020; 52:70-90. [PMID: 31520518 DOI: 10.1002/jmri.26908] [Citation(s) in RCA: 104] [Impact Index Per Article: 20.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Accepted: 08/12/2019] [Indexed: 12/30/2022] Open
Abstract
Diffusion-weighted imaging (DWI) is increasingly being incorporated into routine breast MRI protocols in many institutions worldwide, and there are abundant breast DWI indications ranging from lesion detection and distinguishing malignant from benign tumors to assessing prognostic biomarkers of breast cancer and predicting treatment response. DWI has the potential to serve as a noncontrast MR screening method. Beyond apparent diffusion coefficient (ADC) mapping, which is a commonly used quantitative DWI measure, advanced DWI models such as intravoxel incoherent motion (IVIM), non-Gaussian diffusion MRI, and diffusion tensor imaging (DTI) are extensively exploited in this field, allowing the characterization of tissue perfusion and architecture and improving diagnostic accuracy without the use of contrast agents. This review will give a summary of the clinical literature along with future directions. Level of Evidence: 5 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;52:70-90.
Collapse
Affiliation(s)
- Mami Iima
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
- Department of Clinical Innovative Medicine, Institute for Advancement of Clinical and Translational Science, Kyoto University Hospital, Kyoto, Japan
| | - Maya Honda
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Eric E Sigmund
- Department of Radiology, NYU Langone Health, New York, New York, USA
- Center for Advanced Imaging and Innovation (CAI2R), New York, New York, USA
| | - Ayami Ohno Kishimoto
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Masako Kataoka
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Kaori Togashi
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
| |
Collapse
|
4
|
Simplified perfusion fraction from diffusion-weighted imaging in preoperative prediction of IDH1 mutation in WHO grade II-III gliomas: comparison with dynamic contrast-enhanced and intravoxel incoherent motion MRI. Radiol Oncol 2020; 54:301-310. [PMID: 32559177 PMCID: PMC7409598 DOI: 10.2478/raon-2020-0037] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Accepted: 05/13/2020] [Indexed: 11/20/2022] Open
Abstract
Background Effect of isocitr ate dehydrogenase 1 (IDH1) mutation in neovascularization might be linked with tissue perfusion in gliomas. At present, the need of injection of contrast agent and the increasing scanning time limit the application of perfusion techniques. We used a simplified intravoxel incoherent motion (IVIM)-derived perfusion fraction (SPF) calculated from diffusion-weighted imaging (DWI) using only three b-values to quantitatively assess IDH1-linked tissue perfusion changes in WHO grade II-III gliomas (LGGs). Additionally, by comparing accuracy with dynamic contrast-enhanced (DCE) and full IVIM MRI, we tried to find the optimal imaging markers to predict IDH1 mutation status. Patients and methods Thirty patients were prospectively examined using DCE and multi-b-value DWI. All parameters were compared between the IDH1 mutant and wild-type LGGs using the Mann-Whitney U test, including the DCE MRI-derived Ktrans, ve and vp, the conventional apparen t diffusion coefficient (ADC0,1000), IVIM-de rived perfusion fraction (f), diffusion coefficient (D) and pseudo-diffusion coefficient (D*), SPF. We evaluated the diagnostic performance by receive r operating characteristic (ROC) analysis. Results Significant differences were detected between WHO grade II-III gliomas for all perfusion and diffusion parameters (P < 0.05). When compared to IDH1 mutant LGGs, IDH1 wild-type LGGs exhibited significantly higher perfusion metrics (P < 0.05) and lower diffusion metrics (P < 0.05). Among all parameters, SPF showed a higher diagnostic performance (area under the curve 0.861), with 94.4% sensitivity and 75% specificity. Conclusions DWI, DCE and IVIM MRI may noninvasively help discriminate IDH1 mutation statuses in LGGs. Specifically, simplified DWI-derived SPF showed a superior diagnostic performance.
Collapse
|
5
|
Iima M. Perfusion-driven Intravoxel Incoherent Motion (IVIM) MRI in Oncology: Applications, Challenges, and Future Trends. Magn Reson Med Sci 2020; 20:125-138. [PMID: 32536681 PMCID: PMC8203481 DOI: 10.2463/mrms.rev.2019-0124] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Recent developments in MR hardware and software have allowed a surge of interest in intravoxel incoherent motion (IVIM) MRI in oncology. Beyond diffusion-weighted imaging (and the standard apparent diffusion coefficient mapping most commonly used clinically), IVIM provides information on tissue microcirculation without the need for contrast agents. In oncology, perfusion-driven IVIM MRI has already shown its potential for the differential diagnosis of malignant and benign tumors, as well as for detecting prognostic biomarkers and treatment monitoring. Current developments in IVIM data processing, and its use as a method of scanning patients who cannot receive contrast agents, are expected to increase further utilization. This paper reviews the current applications, challenges, and future trends of perfusion-driven IVIM in oncology.
Collapse
Affiliation(s)
- Mami Iima
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine.,Department of Clinical Innovative Medicine, Institute for Advancement of Clinical and Translational Science (iACT), Kyoto University Hospital
| |
Collapse
|
6
|
Billdal DC, While PT, Selnaes KM, Sunoqrot MRS, Langørgen S, Bertilsson H, Bathen TF, Elschot M. Relative Enhanced Diffusivity in Prostate Cancer: Protocol Optimization and Diagnostic Potential. J Magn Reson Imaging 2019; 51:1900-1910. [PMID: 31794113 DOI: 10.1002/jmri.27011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 11/15/2019] [Accepted: 11/19/2019] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Relative enhanced diffusivity (RED) is a potential biomarker for indirectly measuring perfusion in tissue using diffusion-weighted magnetic resonance imaging (MRI) with 3 b values. PURPOSE To optimize the RED MRI protocol for the prostate, and to investigate its potential for prostate cancer (PCa) diagnosis. STUDY TYPE Prospective. POPULATION Ten asymptomatic healthy volunteers and 35 patients with clinical suspicion of PCa. SEQUENCE 3T T2 - and diffusion-weighted MRI with b values: b = 0, 50, [100], 150, [200], 250, [300], 400, 800 s/mm2 (values in brackets were only used for patients). ASSESSMENT Monte Carlo simulations were performed to assess noise sensitivity of RED as a function of intermediate b value. Volunteers were scanned 3 times to assess repeatability of RED. Patient data were used to investigate RED's potential for discriminating between biopsy-confirmed cancer and healthy tissue, and between true and false positive radiological findings. STATISTICAL TESTS Within-subject coefficient of variation (WCV) to assess repeatability and receiver-operating characteristic curve analysis and logistic regression to assess diagnostic performance of RED. RESULTS The repeatability was acceptable (WCV = 0.2-0.3) for all intermediate b values tested, apart from b = 50 s/mm2 (WCV = 0.3-0.4). The simulated RED values agreed well with the experimental data, showing that an intermediate b value between 150-250 s/mm2 minimizes noise sensitivity in both peripheral zone (PZ) and transition zone (TZ). RED calculated with the b values 0, 150 and 800 s/mm2 was significantly higher in tumors than in healthy tissue in both PZ (P < 0.001, area under the curve [AUC] = 0.85) and PZ + TZ (P < 0.001, AUC = 0.84). RED was shown to aid apparent diffusion coefficient (ADC) in differentiating between false-positive findings and true-positive PCa in the PZ (AUC; RED = 0.71, ADC = 0.74, RED+ADC = 0.77). DATA CONCLUSION RED is a repeatable biomarker that may have value for prostate cancer diagnosis. An intermediate b value in the range of 150-250 s/mm2 minimizes the influence of noise and maximizes repeatability. LEVEL OF EVIDENCE 2 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2020;51:1900-1910.
Collapse
Affiliation(s)
- Daniel C Billdal
- Department of Circulation and Medical Imaging, NTNU, Norwegian University of Science and Technology, Trondheim, Norway
| | - Peter T While
- Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway
| | - Kirsten M Selnaes
- Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway
| | - Mohammed R S Sunoqrot
- Department of Circulation and Medical Imaging, NTNU, Norwegian University of Science and Technology, Trondheim, Norway
| | - Sverre Langørgen
- Department of Circulation and Medical Imaging, NTNU, Norwegian University of Science and Technology, Trondheim, Norway.,Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway
| | - Helena Bertilsson
- Department of Cancer Research and Molecular Medicine, NTNU, Norwegian University of Science and Technology, Trondheim, Norway.,Department of Urology, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway
| | - Tone F Bathen
- Department of Circulation and Medical Imaging, NTNU, Norwegian University of Science and Technology, Trondheim, Norway.,St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway
| | - Mattijs Elschot
- Department of Circulation and Medical Imaging, NTNU, Norwegian University of Science and Technology, Trondheim, Norway.,Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway
| |
Collapse
|
7
|
Jalnefjord O, Montelius M, Starck G, Ljungberg M. Optimization of b-value schemes for estimation of the diffusion coefficient and the perfusion fraction with segmented intravoxel incoherent motion model fitting. Magn Reson Med 2019; 82:1541-1552. [PMID: 31148264 PMCID: PMC6772171 DOI: 10.1002/mrm.27826] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 05/03/2019] [Accepted: 05/05/2019] [Indexed: 01/01/2023]
Abstract
PURPOSE Intravoxel incoherent motion (IVIM) modeling for estimation of the diffusion coefficient (D) and perfusion fraction (f) is increasingly popular, but no consensus on standard protocols exists. This study provides a framework for optimization of b-value schemes for reduced estimation uncertainty of D and f from segmented model fitting. THEORY Analytical expressions for uncertainties of D and f from segmented model fitting were derived as Cramer-Rao lower bounds (CRLBs). METHODS Optimized b-value schemes were obtained for 3 to 12 acquisitions and in the limit of infinitely many acquisitions through constrained minimization of the CRLBs, with b-values constrained to be 0 or 200 to 800 s/mm2 . The optimized b-value scheme with eight acquisitions was compared with b-values linearly distributed in the allowed range using simulations and in vivo liver data from seven healthy volunteers. RESULTS All optimized b-value schemes contained exactly three unique b-values regardless of the total number of acquisitions (0, 200, and 800 s/mm2 ) with repeated acquisitions distributed approximately as 1:2:2. Compared with linearly distributed b-values, the variability of estimates of D and f was reduced by approximately 30% as seen both in simulations and in repeated in vivo measurements. CONCLUSION The uncertainty of IVIM D and f estimates can be reduced by the use of optimized b-value schemes.
Collapse
Affiliation(s)
- Oscar Jalnefjord
- Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Mikael Montelius
- Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Göran Starck
- Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Maria Ljungberg
- Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| |
Collapse
|
8
|
Vidić I, Jerome NP, Bathen TF, Goa PE, While PT. Accuracy of breast cancer lesion classification using intravoxel incoherent motion diffusion‐weighted imaging is improved by the inclusion of global or local prior knowledge with bayesian methods. J Magn Reson Imaging 2019; 50:1478-1488. [DOI: 10.1002/jmri.26772] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2019] [Accepted: 04/16/2019] [Indexed: 12/15/2022] Open
Affiliation(s)
- Igor Vidić
- Department of PhysicsNTNU, Norwegian University of Science and Technology Trondheim Norway
| | - Neil P. Jerome
- Department of Circulation and Medical ImagingNTNU, Norwegian University of Science and Technology Trondheim Norway
- Department of Radiology and Nuclear MedicineSt. Olav's University Hospital Trondheim Norway
| | - Tone F. Bathen
- Department of Circulation and Medical ImagingNTNU, Norwegian University of Science and Technology Trondheim Norway
- Department of Radiology and Nuclear MedicineSt. Olav's University Hospital Trondheim Norway
| | - Pål E. Goa
- Department of PhysicsNTNU, Norwegian University of Science and Technology Trondheim Norway
- Department of Radiology and Nuclear MedicineSt. Olav's University Hospital Trondheim Norway
| | - Peter T. While
- Department of Radiology and Nuclear MedicineSt. Olav's University Hospital Trondheim Norway
| |
Collapse
|
9
|
Comparison of methods for estimation of the intravoxel incoherent motion (IVIM) diffusion coefficient (D) and perfusion fraction (f). MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2018; 31:715-723. [DOI: 10.1007/s10334-018-0697-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2018] [Revised: 07/03/2018] [Accepted: 07/25/2018] [Indexed: 12/11/2022]
|
10
|
Cao M, Suo S, Han X, Jin K, Sun Y, Wang Y, Ding W, Qu J, Zhang X, Zhou Y. Application of a Simplified Method for Estimating Perfusion Derived from Diffusion-Weighted MR Imaging in Glioma Grading. Front Aging Neurosci 2018; 9:432. [PMID: 29358915 PMCID: PMC5766639 DOI: 10.3389/fnagi.2017.00432] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2017] [Accepted: 12/15/2017] [Indexed: 01/21/2023] Open
Abstract
Purpose: To evaluate the feasibility of a simplified method based on diffusion-weighted imaging (DWI) acquired with three b-values to measure tissue perfusion linked to microcirculation, to validate it against from perfusion-related parameters derived from intravoxel incoherent motion (IVIM) and dynamic contrast-enhanced (DCE) magnetic resonance (MR) imaging, and to investigate its utility to differentiate low- from high-grade gliomas. Materials and Methods: The prospective study was approved by the local institutional review board and written informed consent was obtained from all patients. From May 2016 and May 2017, 50 patients confirmed with glioma were assessed with multi-b-value DWI and DCE MR imaging at 3.0 T. Besides conventional apparent diffusion coefficient (ADC0,1000) map, perfusion-related parametric maps for IVIM-derived perfusion fraction (f) and pseudodiffusion coefficient (D*), DCE MR imaging-derived pharmacokinetic metrics, including Ktrans, ve and vp, as well as a metric named simplified perfusion fraction (SPF), were generated. Correlation between perfusion-related parameters was analyzed by using the Spearman rank correlation. All imaging parameters were compared between the low-grade (n = 19) and high-grade (n = 31) groups by using the Mann-Whitney U test. The diagnostic performance for tumor grading was evaluated with receiver operating characteristic (ROC) analysis. Results: SPF showed strong correlation with IVIM-derived f and D* (ρ = 0.732 and 0.716, respectively; both P < 0.001). Compared with f, SPF was more correlated with DCE MR imaging-derived Ktrans (ρ = 0.607; P < 0.001) and vp (ρ = 0.397; P = 0.004). Among all parameters, SPF achieved the highest accuracy for differentiating low- from high-grade gliomas, with an area under the ROC curve value of 0.942, which was significantly higher than that of ADC0,1000 (P = 0.004). By using SPF as a discriminative index, the diagnostic sensitivity and specificity were 87.1% and 94.7%, respectively, at the optimal cut-off value of 19.26%. Conclusion: The simplified method to measure tissue perfusion based on DWI by using three b-values may be helpful to differentiate low- from high-grade gliomas. SPF may serve as a valuable alternative to measure tumor perfusion in gliomas in a noninvasive, convenient and efficient way.
Collapse
Affiliation(s)
- Mengqiu Cao
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Shiteng Suo
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Xu Han
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Ke Jin
- Department of Neurosurgery, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Yawen Sun
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Yao Wang
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Weina Ding
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | | | - Xiaohua Zhang
- Department of Neurosurgery, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Yan Zhou
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|